Sei sulla pagina 1di 142

STRUCTURAL DESIGN CALCULATIONS

FOR
NORTH CARGO BERTH – II, TUTICORIN PORT

“Transfer Tower- JTT-06”

© This document is, unless otherwise agreed in writing, the property of the property of FGI, and
shall not be reproduced, copied, disclosed to any third party or used for any purpose other than
that for which it is supplied or disclosed.

0 FIRST ISSUE 17-07-13 B.S.K R.S.R

DATE OF PREPARED DESIGNED CHECKED APPROVED


REV.NO DESCRIPTION
ISSUE BY BY BY BY

DOCUMENT NO.: CLIENT :

V.O.Chidambaranar Port Trust


NORTH CARGO BERTH – II
19260009-CAL-ME-JTT6-0001
Tuticorin Coal Terminal Pvt Ltd
tuticorin Port

DOCUMENT TITLE:

DESIGN OF
TRANSFER TOWER – JTT-06
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

CONTENTS
1. GENERAL 03
1.1 SCOPE 03
1.2 UNITS OF MEASUREMENTS 03
1.3 CODES AND REFERENCES 03
1.4 MATERIAL PROPERTIES 03
1.5 PLANT SITE INFORMATION 03
1.6 SOFTWARE REFERENCE 04
2. DESCRIPTION OF STRUCTURE & GEOMETRY 04
3. DESIGN PHILOSOPHY 05
3.1 BASIC LOAD CASES 06
3.2 LOAD CALCULATIONS 07
3.2.1 DEAD LOAD 07
3.2.2 EQUIPMENT LOAD 10
3.2.3 MATERIAL LOAD 13
3.2.4 LIVE LOAD 15
3.2.5 WIND LOAD 18
3.2.6 BELT TENSION 27
3.2.7 MONORAIL LOAD 28
3.2.8 MATERIAL JAMMING LOAD 29
3.2.9 SEISMIC LOAD 31
3.3 LOAD COMBINATIONS 32
4. DESIGN OF TRANSFER TOWER 36
4.1 STAAD MODEL SKETCH 36
4.2 STAAD INPUT 48
4.3 DESIGN OF MEMBERS- STAAD OUTPUT 62
4.4 MEMBER STRESS RATIOS 99
4.5 SUPPORT REACTIONS FOR BASE PLATE 108
4.6 DESIGN OF BASE PLATE 116
4.7 REACTIONS FOR FOUNDATION 138

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 2
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

1. GENERAL

1.1 SCOPE

This Document Covers the analysis and design of Transfer Tower for supporting the Conveyor
gallery at drive head and tail head locations Coal Handling System of Tuticorin port, located in the
Tutocorin, Tamil Nadu State, India. The objective of the calculations in this document is to design
columns, floor beams, base plates and anchor bolts of Transfer Tower JTT-6.

1.2 UNITS OF MEASUREMENTS

Units of measurements used in analysis shall be of SI Units.

1.3 CODES AND REFERENCES

The following codes and references have been referred:

Project Reference Drawings / Documents


1 19260009-DRW-ME-JTT6-0001 GENERAL ASSEMBLY
Indian Standard Codes
1 IS 800 – 2007 Code of Practice for General Construction in Steel
Code of Practice for Design Loads for Building and
2 IS 875 – 1987 (I to III)
Structures.
Indian Standard Code of Practice Plain and Reinforced
3 IS 456 - 2000
Concrete.
4 IS1893 - 2002 Criteria for Earthquake Resistant Design of Structures.

1.4 MATERIAL PROPERTIES

Material Property Value Units


Density 78.5 kN/cu.m.
High Strength Structural Steel Yield Stress (fy) 250 N/sq.mm
Modulus of Elasticity (E) 2 x 105 MPa

1.5 PLANT SITE INFORMATION

Location of the Site : Tuticorin


Seismic Zone : Zone II
Basic Wind Speed : 39 m/sec

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 3
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

1.6 SOFTWARE REFERENCE

STAAD – Pro V8i, Research Engineers Inc., Bentley, USA

The above software package is renowned and well used and accepted internationally for
similar type of structural analysis carried out in this document. In-house developed programs and
spread sheets are used for the design of combined footings, footings and beams. Columns are
designed by using Staad Pro.

2. DESCRIPTION OF STRUCTURE & GEOMETRY


The structure is basically a Transfer Tower in the Coal Handling Plant area. The Transfer
Tower having two floors +8.20m lvl, +12.092m lvl and Monorail at +17.70m lvl., The Conv. CV- 08
drive machines are supported at +12.02m lvl. Floor.
The Columns are supported over the concrete pedestals and foundation. The transfer tower
supporting columns are analyzed for the various loads transferred from the gallery and floors. All the
columns are designed for Dead loads, Equipment load, Material loads, Live loads, Wind loads and
Seismic loads. Layout and typical floor plans of transfer tower are as shown below.

+17.892M LVL

+12.092 M LVL

+8.20 M LVL

+9.65 M LVL
+3.95 M LVL

2 A
`
3
B
Isometric View of Staad Model

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 4
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3. DESIGN PHILOSOPHY
The transfer tower structure is modeled in Staad as space frame structure with fixed base &
analysed for the various loads transferred from the floor. From the reactions of standard galleries,
loads are interpolated for the actual spans and for the actual height of the gallery. Thus arrived loads
are applied on the JTT-06.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 5
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3D View of STAAD Model


3.1 BASIC LOAD CASES

The Following primary load cases are considered for JTT-06 structure design

LOAD CASE
LOAD CASE NAME
NUMBER
1 DEAD LOAD (DL)
2 EQUIPMENT LOAD (EL)
3 MATERIAL LOAD (ML)
4 LIVE LOAD (LL)
5 WIND LOAD IN (+ X DIR)
6 WIND LOAD IN (- X DIR)
7 WIND LOAD IN (+ Z DIR)
8 WIND LOAD IN (- Z DIR)
9 SEISMIC LOAD (+ X DIR)
10 SEISMIC LOAD (+ Z DIR)
11 BELT TENSION (BT)
12 MONO RAIL LOAD (MR)
13 MATERIAL JAM LOAD (MJ)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 6
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3.2 Load Calculations

3.2.1 Dead Load


a. Loads Consider on Transfer Tower
Weight of Stair case floor grating 30 Kgs/sq.m 30/100 = 0.3 kN/sq.m
Load on Stair case udl 0.9 m span = (0.9*0.3)/2 = 0.135 kN/m
Weight of Panels 560 kgs (560/4) = 140.00 kgs
at floor lvl on the column 1.40 kN
Roof sheeting load 26 kg/sq.m = 0.26 kN/m2
Wall Cladding load 36 kg/sq.m = 0.36 kN/m2

Portal Effective width Load (P) kN/m


weight/m2
no w m windward Leeward
L1 4.25/2 2.125 0.26 0.55 0.55
L2 (4.25+4.25)/2 4.25 0.26 1.11 1.11
L3 (4.25+5.0)/2 4.625 0.26 1.20 1.20
L4 5.0/2 2.5 0.26 0.65 0.65

weight Udl weight Udl


Grid -1 Width (m) Grid -2 & 3 Width (m)
(kN/m2) (kN/m) (kN/m2) (kN/m)
w1 5.0 0.36 1.80 w3 5.0 0.36 1.80
w2 5.0 0.36 1.80 w4 5.0 0.36 1.80
Grid -A Width (m) weight Udl Grid -B Width (m) weight Udl
w5 4.25 0.36 0.77 w8 4.25 0.36 0.77
w6 6.75 0.36 1.22 w9 6.75 0.36 1.22
w7 2.5 0.36 0.45 w10 2.5 0.36 0.45

b. Loads considered for each of conveyors SRC-01


Weight of wind guard on each stringer 40 kg/m 40/2 = 20 kg/m
20/100 = 0.2 kN/m
Weight of Railing 25 kg/m 25/100 = 0.25 kN/m
Water pipe for DSS 21 kg/m 21/100 = 0.21 kN/m
Water pipe for FF 21 kg/m 21/100 = 0.21 kN/m
0.67 kN/m
Weight of Floor grating 30 kg/sq.m 30/100 = 0.3 kN/sq.m
Width of Walkway 1000 mm 1000/1000 = 1 m
Load on Walkway (0.3x1) = 0.3 kN/m
(0.2 + 0.67 + 0.3) 1.170 kN/m
Weight of elevated frame 250 kg/m 250/100 = 2.5 kN/m
Length of SRC-01 5.524 m
Load of SRC-01 on Transfer Tower ((1.17x5.524+2.5x5.524) /2)= P1, P2 = 10.14 kN

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 7
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

c. Loads considered for head frame


Weight of Hood on each stringer 80 kg/m 80/2 = 40 kg/m
40/100 = 0.4 kN/m
Weight of Railing 25 kg/m 25/100 = 0.25 kN/m
Water pipe for DSS 21 kg/m 21/100 = 0.21 kN/m
Water pipe for FF 21 kg/m 21/100 = 0.21 kN/m
0.67 kN/m
Weight of Floor grating 30 kg/sq.m 30/100 = 0.3 kN/sq.m
Width of Walkway 800 mm 800/1000 = 0.8 m
Load on Walkway (0.3x0.8) = 0.24 kN/m
(0.4 + 0.67 + 0.24) 1.310 kN/m
Weight of elevated frame 250 kg/m 250/100 = 2.5 kN/m
Length of CV-08 11.043 m
Load of CV-08 on Transfer Tower ((1.31x11.043+2.5x11.043) /2)= P3, P4 = 21.04 kN

d. Loads considered for head frame (SRC-01 & CV-08)


Self Weight of the Structure = Directly arrived from model

Dead Load (DL) at +8.20m lvl (Image -01)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 8
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Dead Load (DL) at +12.092m lvl (Image -02)

Dead Load (DL) Image -03

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 9
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3.2.2 Equipment Load


a. Loads Considered For Transfer Tower
Weight of Head Chute = 4000 kgs
Ref: As per doc.
Weight of Discharge Chute 780kg/ m 1.75 m = 1365 kgs
Ref: As per Doc.
Weight of Belt Cleaner 250 kgs = 250 kgs

Protections 400 kg = 400 kgs


Total 6015 kgs
Load on each member = 6015/4 = 1503.75 kgs = 15.04 kN

b. Loads Considered for Conveyor SRC-01


Weight of Upper Idlers 81 kg/m 81 = 67.5 kg/m
Weight of Lower Idlers 64 kg/m 64 = 64.0 kg/m
weight of Belt Conveyor ST-800 5+5 36.7 kg/m 36.7x 2 = 73.4 kg/m
Weight of Idler Stringer 46 kg/m = 46 kg/m
Weight of Cable Tray 150 kg/m = 150 kg/m
Total 400.90 kg/m
401.0 kg/m
Load on each member ((401)/2)/100 = 2.005 kN/m
Load of SRC-01 on Transfer Tower (2.005x5.524/2) = P1, P2 = 5.538 kN

c. Loads Considered for Conveyor CV-08


Weight of Upper Idlers 81 kg/m 81/1.2= 67.5 kg/m
Weight of Lower Idlers 64 kg/m 64 = 64.0 kg/m
weight of Belt Conveyor (EP-63/5 5+3) 27.9 kg/m 27.9x 2 = 55.8 kg/m
Weight of Idler Stringer 46 kg/m = 46 kg/m
Weight of Cable Tray 150 kg/m = 150 kg/m
Total 383.30 kg/m
384.0 kg/m
Load on each member ((384)/2)/100 = 1.920 kN/m
Load of SRC-01 on Transfer Tower (1.92x11.043/2) = P3, P4 = 10.601 kN

d. Loads Considered for Head Frame


HEAD FRAME ASSEMBLY FOR SRC-01
Weight of the Pulley 1700 kg 1700/100 = 17.00 kN
Weight of the Drive set 10500 kg 10500/100 = 105 kN
50 % Weight of Drive set 105 x 50% = 52.50 kN
It’s a Single Drive arrangement Load for Drive 17/2+52.5 = 61.00 kN
Moment from Cg of load to centre of the support (mm) 392 Mz = 3.332 kN.m
Weight of snub pulley 550 kg 550/100 = 5.5 kN

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 10
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Weight of the Snub pulley on each joint 5.5/2 = 2.75 kN


Moment from Snub pulley to centre of the support (mm) 282 Mz = 0.776 kN.m
Moment from the Drive set to centre of the shaft (mm) 1365 Mx = 71.66 kN.m

e. Loads Considered for Head Frame


Weight of the Pulley 1700 kg 1700/100 = 17.00 kN
Weight of the Drive set 6500 kg 6500/100 = 65 kN
50 % Weight of Drive set 65 x 50% = 32.50 kN
It’s a Single Drive arrangement Load for Drive 17/2+32.5 = 41.00 kN
Moment from Cg of load to center of the support (mm) 390 Mz = 3.315 kN.m
Weight of snub pulley 550 kg 550/100 = 5.5 kN
Weight of the Snub pulley on each joint 5.5/2 = 2.75 kN
Moment from Snub pulley to center of the support (mm) 282 Mz = 0.776 kN.m
Moment from the Drive set to center of the shaft (mm) 1100 Mx = 35.75 kN.m

Equipment Load (EL) on floor at +12.092m lvl (image-01)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 11
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Equipment Load (EL) on floor at +8.20m lvl (image-02)

Equipment Load (EL) on floor at +8.20m lvl (image-03)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 12
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Equipment Load (EL) on floor at +12.092m lvl (image-04)

3.2.3 Material Load


a. Loads considered for Conveyor SRC-01

a. Loads considered for Conveyor CV-08

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 13
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Material Load (ML) AT +12.092M LVL (image-01)

Material Load (ML) AT +8.20M LVL (image-02)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 14
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3.2.4 Live Load


a. Loads considered for Trasfer Tower
Floor Load on +8.20 m level 500 Kgs/sq.m 500/100 = 5.0 kN/sq.m
Floor Load on Staircase level 250 Kgs/sq.m 250/100 = 2.5 kN/sq.m
Stair case member load 0.9 m span (0.9*2.5)/2 1.125 kN/m
Roof sheeting load 100 kg/sq.m = 1.0 kN/m2

Portal Effective width Load (P) kN/m


Load/m2
no w m windward Leeward
L1 4.25/2 2.125 1.0 2.13 2.13
L2 (4.25+4.25)/2 4.25 1.0 4.25 4.25
L3 (4.25+5.0)/2 4.625 1.0 4.63 4.63
L3 5.0/2 2.5 1.0 2.50 2.50

b. Loads considered for each of Conveyor SRC-01


Weight of walkway Floor Load 250 Kgs/sq.m 2.5 kN/sq.m
Width of Walkway 1000 mm 1000/1000 = 1.0 m
Load on walkway 2.5x 1 = 2.5 kN/sq.m
Load of SRC-01 on Transfer Tower (2.5x5.524/2) = P1, P2 = 6.905 kN

a. Loads considered for each of Conveyor CV-08


Weight of walkway Floor Load 250 Kgs/sq.m 2.5 kN/sq.m
Width of Walkway 800 mm 800/1000 = 0.8 m
Load on walkway 2.5x 0.8 = 2.0 kN/sq.m
Load of CV-08 on Transfer Tower (2x11.043/2) = P1, P2 = 11.043 kN

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 15
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Live Load (LL) on Floor at +8.20 m lvl image-01

Live Load (LL) on Floor at +12.092 m lvl( image-02)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 16
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Live Load (LL) image-03

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 17
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3.2.5 Wind Load (WL)


a. Loads considered for Transfer Tower

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 18
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 19
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

b. Loads considered for Conveyor SRC-01 Head Chute

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 20
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

c. Loads considered for Conveyor Cv-08

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 21
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 22
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

d. Loads considered for Conveyor SRC-01

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 23
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 24
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Wind load (WL) +X Dir image-01

Wind load (WL) -X Dir image-02

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 25
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Wind load (WL) +Z Dir image-03

Wind load (WL) -Z Dir image-04

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 26
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3.2.6 Belt Tension


a. Loads Considered on Head Frame

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 27
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Belt Tension Load (BT)

3.2.7 Mono Rail Load (MR)


a. Loads considered on Trasnfer Tower
Weight of the Mono Rail 5.0 Tons 5 x 10 = 50 kN

Load on each node 50/6 = 8.33 kN

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 28
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Mono Rail Load (MR)

3.2.8 Material Jamming Load (MJ)


a. Loads considered on Conveyor SRC-01

Volume of the chute (1.151*1.875*2.94) = 6.34 m3


Ref Dwg: GA
Density of the material = 800 kg/m3
Weight of Discharge Chute (6.34*8)/4 = 12.68 kN

b. Loads considered on Conveyor CV-08


Volume of the chute (1.866*1.588*5.83) = 17.28 m3
Ref Dwg: GA
Density of the material = 800 kg/m3
Weight of Discharge Chute (17.28*8)/4 = 34.56 kN

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 29
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Material Jamming load (MJ) at +12.092m lvl (image-01)

Material Jamming load (MJ) at +8.20m lvl (image-02)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 30
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

3.2.9 Seismic Load


The seismic load is defined in staad.
Seismic Hazard Zone 2 -- Seismic Zone Factor = 0.1
Importance Factor -- 1.75
Response Reduction Factor -- R = 4
For the seismic loads, STAAD model has been created where all the joints where members
are connected have been considered as pinned. This has been done to obtain the support reactions at
these points due to dead loads, live loads, equipment loads & material loads. The support reactions
so obtained has been applied in the STAAD model as mass at different levels in the X & Z directions
for estimating the seismic response.

Seismic Load in +X Direction

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 31
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Seismic Load in +Z Direction


3.3 Load Combinations

a) The Following Load combinations are considered for Transfer Tower JTT-06 structure,
base plate and RCC pedestal design :
*****************************************************************************
*******AS PER IS800 2007 LOAD COMBINATIONS FOR LIMIT STATE OF COLLAPSE*******
*****************************************************************************
LOAD COMB 220 (1.5DL + 1.5EQUIP + 1.5LL + 1.5ML + 1.5BT)
1 1.5 2 1.5 3 1.5 4 1.5 11 1.5
LOAD COMB 221 (1.5DL + 1.5EQUIP + 1.5LL + 1.5 MR)
1 1.5 2 1.5 4 1.5 12 1.5
LOAD COMB 222 (1.5DL + 1.5EQUIP + 0.6LL + 1.5 MJ)
1 1.5 2 1.5 4 0.6 13 1.5
LOAD COMB 223 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (X) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 5 1.2
LOAD COMB 224 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (-X) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 6 1.2
LOAD COMB 225 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (Z) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 7 1.2
LOAD COMB 226 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (-Z) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 8 1.2
LOAD COMB 227 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (X) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 9 1.2
LOAD COMB 228 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (-X) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 9 -1.2
LOAD COMB 229 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (Z) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 10 1.2

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 32
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

LOAD COMB 230 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (-Z) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 10 -1.2
LOAD COMB 231 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (X) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 5 1.2
LOAD COMB 232 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (-X) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 6 1.2
LOAD COMB 233 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (Z) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 7 1.2
LOAD COMB 234 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (-Z) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 8 1.2
LOAD COMB 235 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (X) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 9 1.2
LOAD COMB 236 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (-X) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 9 -1.2
LOAD COMB 237 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (Z) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 10 1.2
LOAD COMB 238 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (-Z) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 10 -1.2
LOAD COMB 239 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (X) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 5 1.2
LOAD COMB 240 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (-X) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 6 1.2
LOAD COMB 241 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (Z) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 7 1.2
LOAD COMB 242 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (-Z) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 8 1.2
LOAD COMB 243 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (X) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 9 1.2
LOAD COMB 244 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (-X) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 9 -1.2
LOAD COMB 245 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (Z) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 10 1.2
LOAD COMB 246 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (-Z) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 10 -1.2
*** 0.9 DL + 1.5WL/1.5SL
LOAD COMB 247 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (X) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 5 1.5
LOAD COMB 248 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (-X) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 6 1.5
LOAD COMB 249 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (Z) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 7 1.5
LOAD COMB 250 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (-Z) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 8 1.5
LOAD COMB 251 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (X) DIR)
1 0.9 2 0.9 12 0.9 5 1.5
LOAD COMB 252 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (-X) DIR)
1 0.9 2 0.9 12 0.9 6 1.5
LOAD COMB 253 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (Z) DIR)
1 0.9 2 0.9 12 0.9 7 1.5
LOAD COMB 254 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (-Z) DIR)
1 0.9 2 0.9 12 0.9 8 1.5
LOAD COMB 255 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (X) DIR)
1 0.9 2 0.9 13 0.9 5 1.5
LOAD COMB 256 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (-X) DIR)
1 0.9 2 0.9 13 0.9 6 1.5
LOAD COMB 257 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (Z) DIR)
1 0.9 2 0.9 13 0.9 7 1.5
LOAD COMB 258 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (-Z) DIR)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 33
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

1 0.9 2 0.9 13 0.9 8 1.5


LOAD COMB 259 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (X) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 9 1.5
LOAD COMB 260 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (-X) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 9 -1.5
LOAD COMB 261 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (Z) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 10 1.5
LOAD COMB 262 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (-Z) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 10 -1.5
LOAD COMB 263 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (X) DIR)
1 0.9 2 0.9 12 0.9 9 1.5
LOAD COMB 264 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (-X) DIR)
1 0.9 2 0.9 12 0.9 9 -1.5
LOAD COMB 265 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (Z) DIR)
1 0.9 2 0.9 12 0.9 10 1.5
LOAD COMB 266 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (-Z) DIR)
1 0.9 2 0.9 12 0.9 10 -1.5
LOAD COMB 267 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (X) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 9 1.5
LOAD COMB 268 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (-X) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 9 -1.5
LOAD COMB 269 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (Z) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 10 1.5
LOAD COMB 270 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (-Z) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 10 -1.5
**** 1.5 DL+1.5WL/SL
LOAD COMB 271 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 5 1.5
LOAD COMB 272 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (-X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 6 1.5
LOAD COMB 273 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 7 1.5
LOAD COMB 274 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (-Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 8 1.5
LOAD COMB 275 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 9 1.5
LOAD COMB 276 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (-X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 9 -1.5
LOAD COMB 277 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 10 1.5
LOAD COMB 278 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (-Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 10 -1.5
LOAD COMB 279 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (X) DIR)
1 1.5 2 1.5 12 1.5 5 1.5
LOAD COMB 280 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (-X) DIR)
1 1.5 2 1.5 12 1.5 6 1.5
LOAD COMB 281 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (Z) DIR)
1 1.5 2 1.5 12 1.5 7 1.5
LOAD COMB 282 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (-Z) DIR)
1 1.5 2 1.5 12 1.5 8 1.5
LOAD COMB 283 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SLQ IN (X) DIR)
1 1.5 2 1.5 12 1.5 9 1.5
LOAD COMB 284 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SL IN (-X) DIR)
1 1.5 2 1.5 12 1.5 9 -1.5
LOAD COMB 285 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SL IN (Z) DIR)
1 1.5 2 1.5 12 1.5 10 1.5
LOAD COMB 286 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SL IN (-Z) DIR)
1 1.5 2 1.5 12 1.5 10 -1.5

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 34
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

LOAD COMB 287 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5WIND IN (X) DIR)


1 1.5 2 1.5 13 1.5 5 1.5
LOAD COMB 288 (1.5DL + 1.5EQUIP + 1.5MJ +1.5WIND IN (-X) DIR)
1 1.5 2 1.5 13 1.5 6 1.5
LOAD COMB 289 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5WIND IN (Z) DIR)
1 1.5 2 1.5 13 1.5 7 1.5
LOAD COMB 290 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5WIND IN (-Z) DIR)
1 1.5 2 1.5 13 1.5 8 1.5
LOAD COMB 291 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SLQ IN (X) DIR)
1 1.5 2 1.5 13 1.5 9 1.5
LOAD COMB 292 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SL IN (-X) DIR)
1 1.5 2 1.5 13 1.5 9 -1.5
LOAD COMB 293 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SL IN (Z) DIR)
1 1.5 2 1.5 13 1.5 10 1.5
LOAD COMB 294 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SL IN (-Z) DIR)
1 1.5 2 1.5 13 1.5 10 -1.5
******************************************************************************
*****AS PER IS800 2007 LOAD COMBINTIONS FOR LIMIT STATE OF SERVICEABILITY*****
LOAD COMB 295 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0
LOAD COMB 296 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR)
1 1.0 2 1.0 4 1.0 12 1.0
LOAD COMB 297 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ)
1 1.0 2 1.0 4 1.0 13 1.0
LOAD COMB 298 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 5 1.0
LOAD COMB 299 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (-X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 6 1.0
LOAD COMB 300 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 7 1.0
LOAD COMB 301 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (-Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 8 1.0
LOAD COMB 302 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 9 1.0
LOAD COMB 303 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (-X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 9 -1.0
LOAD COMB 304 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 10 1.0
LOAD COMB 305 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (-Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 10 -1.0
LOAD COMB 306 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 5 1.0
LOAD COMB 307 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (-X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 6 1.0
LOAD COMB 308 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 7 1.0
LOAD COMB 309 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 8 1.0
LOAD COMB 310 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 9 1.0
LOAD COMB 311 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (-X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 9 -1.0
LOAD COMB 312 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 10 1.0
LOAD COMB 313 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 10 -1.0
LOAD COMB 314 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 5 1.0

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 35
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

LOAD COMB 315 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (-X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 6 1.0
LOAD COMB 316 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 7 1.0
LOAD COMB 317 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 8 1.0
LOAD COMB 318 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 9 1.0
LOAD COMB 319 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (-X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 9 -1.0
LOAD COMB 320 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 10 1.0
LOAD COMB 321 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 10 -1.0

4. DESIGN OF TRANSFER TOWER


4.1 Staad Model Sketch

A
2

Isometric view
3
B

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 36
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+250x16F

600x12W+300x25F

Member Properties of Along Grid – A

Member Stress Ratios of Along Grid – A

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 37
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+250x16F

600x12W+300x25F

Member Properties Along Grid – B

Member Stress Ratios of Along Grid – B

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 38
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+300x25F

Member Properties Along Grid – 1

Member Stresses Ratios Along Grid – 1

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 39
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+300x16F

Member Properties Along Grid –2

Member Stresses Ratios Along Grid – 2

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 40
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+300x16F

Member Properties Along Grid – 3

Member Stresses Ratios Along Grid – 3

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 41
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+300x25F 600x12W+300x25F

500x12W+300x25F

600x12W+300x25F
500x12W+300x25F

Floor at +8.20m lvl Member Properties

Floor at +8.20m lvl Member Stress Ratios

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 42
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Floor at +9.65m lvl Member Properties

Floor at +9.65m lvl Member Stress Ratios

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 43
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

500x12W+250x16F

500x12W+300x16F

500x12W+250x16F
500x12W+300x16F

Floor at +12.092m lvl Member Properties

Floor at +12.092m lvl Member Stress Ratios

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 44
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Stair case Member Properties

Stair case Member Stress Ratios

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 45
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

SRC-01 of Head Frame Member Properties & Member Stress Ratios

CV-08 Head Frame Member Properties & Member Stress Ratios

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 46
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Member Properties of Purlins & Mono Rail

Member Stress Ratios of Purlins & Mono Rail

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 47
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

4.2 Staad Input


STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 24-Jun-13*
JOB NAME JTT-06
JOB CLIENT TUTICORIN PORT
JOB REV A
JOB PART SRC-01
JOB REF 19260009-DRW-ME-JTT6-0001-3
ENGINEER NAME R.S.R
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0 3.95 0; 2 10 3.95 0; 3 0 3.95 8.5; 4 10 3.95 8.5; 5 0 3.95 13.5;
6 10 3.95 13.5; 7 0 17.892 0; 8 10 17.892 0; 9 0 17.892 8.5; 10 10 17.892 8.5;
11 0 17.892 13.5; 12 10 17.892 13.5; 13 0 8.2 0; 14 10 8.2 0; 15 5 8.2 0;
16 8 8.2 0; 17 0 12.092 0; 18 10 12.092 0; 19 5 12.092 0; 20 8 12.092 0;
21 0 14.592 0; 22 10 14.592 0; 23 5 14.592 0; 24 8 14.592 0; 25 0 17.092 0;
26 10 17.092 0; 27 5 17.092 0; 28 8 17.092 0; 29 5 19.517 0;
30 1.18879 18.2784 0; 31 2.37759 18.6647 0; 32 3.56638 19.0511 0;
33 4.75517 19.4374 0; 34 8.81121 18.2784 0; 35 7.62241 18.6647 0;
36 6.43362 19.0511 0; 37 5.24483 19.4374 0; 38 8.42623 18.4035 0;
39 8 18.542 0; 40 10 5.624 0; 41 11.525 5.624 0; 42 12.325 5.624 0;
43 0 9.65 8.5; 44 10 9.65 8.5; 45 0 12.092 8.5; 46 10 12.092 8.5;
47 1.6 9.65 8.5; 48 1.6 12.092 8.5; 49 5.825 9.65 8.5; 50 5.825 12.092 8.5;
51 5 19.517 8.5; 52 1.18879 18.2784 8.5; 53 8.81121 18.2784 8.5;
54 2.37759 18.6647 8.5; 55 7.62241 18.6647 8.5; 56 3.56638 19.0511 8.5;
57 6.43362 19.0511 8.5; 58 4.75517 19.4374 8.5; 59 5.24483 19.4374 8.5;
60 1.18879 18.2784 13.5; 61 8.81121 18.2784 13.5; 62 2.37759 18.6647 13.5;
63 7.62241 18.6647 13.5; 64 3.56638 19.0511 13.5; 65 6.43362 19.0511 13.5;
66 4.75517 19.4374 13.5; 67 5.24483 19.4374 13.5; 68 5 19.517 13.5;
69 0 9.65 13.5; 70 10 9.65 13.5; 71 0 12.092 13.5; 72 10 12.092 13.5;
73 0 14.592 13.5; 74 10 14.592 13.5; 75 0 17.092 13.5; 76 10 17.092 13.5;
77 1.6 9.65 13.5; 78 5.825 9.65 13.5; 79 1.6 12.092 13.5; 80 5.825 12.092 13.5;
81 1.6 17.092 13.5; 82 5.825 17.092 13.5; 83 1.6 14.592 13.5;
84 5.825 14.592 13.5; 85 5 17.092 13.5; 86 0 12.092 4.25; 87 0 17.892 4.25;
88 10 12.092 4.25; 89 10 17.892 4.25; 90 1.18879 18.2784 4.25;
91 8.81121 18.2784 4.25; 92 2.37759 18.6647 4.25; 93 7.62241 18.6647 4.25;
94 3.56638 19.0511 4.25; 95 6.43362 19.0511 4.25; 96 4.75517 19.4374 4.25;
97 5.24483 19.4374 4.25; 98 5 19.517 4.25; 99 0 8.2 8.5; 100 0 6.8 8.5;
101 0 6.8 13.5; 102 0 8.2 1.75; 103 0 8.2 6.25; 104 0 12.092 1.75;
105 0 12.092 6.25; 106 0 14.592 8.5; 107 0 14.592 4.25; 108 10 6.8 8.5;
109 10 6.8 13.5; 110 10 8.2 8.5; 111 10 14.592 8.5; 112 10 14.592 4.25;
113 11.525 3.95 3.093; 114 12.325 3.95 3.093; 115 11.525 5.624 0.6;
116 12.325 5.624 0.6; 117 11.275 5.624 0.6; 118 10.475 5.624 0.6;
119 11.275 5.624 0; 120 10.475 5.624 0; 121 10 8.2 4.413; 122 10.475 8.2 4.413;
123 11.275 8.2 4.413; 124 10.475 8.2 3.878; 125 11.275 8.2 3.878;
126 10.475 8.2 4.788; 127 11.275 8.2 4.788; 128 10 12.092 10.675;
129 10.475 12.092 10.675; 130 11.275 12.092 10.675; 131 10.475 12.092 10.14;
132 11.275 12.092 10.14; 133 10.475 12.092 11.125; 134 11.275 12.092 11.125;
135 4 8.2 0; 136 6 8.2 0; 137 2 6.075 0; 138 8 6.075 0; 139 11.1625 4.787 0;
140 2.5 12.092 0; 141 2.5 14.592 0; 142 2.5 17.092 0; 143 1.25 10.146 0;
144 3.75 10.146 0; 145 3.115 9.65 8.5; 146 7.285 9.65 8.5; 147 1.5575 6.8 8.5;
148 8.6425 6.8 8.5; 149 3.7125 12.092 8.5; 150 7.9125 12.092 8.5;
151 3.115 9.65 13.5; 152 7.285 9.65 13.5; 153 3.7125 12.092 13.5;
154 7.9125 12.092 13.5; 155 7.9125 17.092 13.5; 156 7.9125 14.592 13.5;
157 1.5575 6.8 13.5; 158 8.6425 6.8 13.5; 159 10 8.2 4.25; 160 10 6.8 11;
161 10 9.65 11; 162 10 17.892 11; 163 10 12.092 3.8; 164 10 12.092 5.005;
165 10 10.146 1.9; 166 10 10.146 6.7525; 167 10 6.075 2.125;
168 10 6.075 6.375; 169 10 14.592 11.114; 170 10 14.592 9.909;
171 10 12.092 9.909; 172 10 12.092 11.114; 173 0 6.8 11; 174 0 9.65 11;
175 0 12.092 11; 176 0 17.892 11; 177 0 14.592 11; 178 0 8.2 4.25;

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 48
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

179 0 6.075 2.125; 180 0 6.075 6.375; 181 0 8.2 1.485; 182 10 8.2 1.485;
183 0 8.2 2.875; 184 10 8.2 2.875; 185 0 8.2 5.125; 186 10 8.2 5.125;
187 0 8.2 7.63; 188 10 8.2 7.63; 189 2.81 8.2 2.875; 190 2.81 8.2 5.125;
191 4.11 8.2 2.875; 192 4.11 8.2 5.125; 193 6.11 8.2 2.875; 194 6.11 8.2 5.125;
195 2.81 8.2 7.63; 196 4.11 8.2 7.63; 197 6.11 8.2 7.63; 198 4.11 8.2 1.485;
199 2.81 8.2 1.485; 200 6.11 8.2 1.485; 201 6.11 8.2 0; 202 2.81 8.2 0;
203 4.11 8.2 0; 204 8 8.2 1.485; 205 8 8.2 2.875; 206 8 8.2 5.125;
207 8 8.2 7.63; 208 2.873 12.092 8.5; 209 4.021 12.092 8.5;
210 6.368 12.092 8.5; 211 1.393 12.092 13.5; 212 2.541 12.092 13.5;
213 4.888 12.092 13.5; 214 3.05189 12.092 11.774; 215 5.20986 12.092 12.4126;
216 3.42086 12.092 10.5275; 217 5.57884 12.092 11.1661; 218 1.35 17.7 13.5;
219 7.807 17.7 0; 220 7.807 18.6047 0; 221 1.35 18.3308 13.5;
222 8.66996 17.7 -1.80424; 223 2.81 8.738 2.875; 224 2.81 8.738 5.125;
225 4.11 10.192 2.875; 226 4.11 10.192 5.125; 227 2.81 8.4 2.875;
228 2.81 8.4 5.125; 229 4.11 8.4 2.875; 230 4.11 8.4 5.125; 231 4.11 9.6 2.875;
232 4.11 9.6 5.125; 233 3.30166 12.092 10.9302; 234 5.45964 12.092 11.5688;
235 3.30166 14.084 10.9302; 236 5.45964 14.084 11.5688;
237 3.05189 12.63 11.774; 238 5.20986 12.63 12.4126;
239 3.30166 13.392 10.9302; 240 5.45964 13.392 11.5688;
241 3.30166 12.242 10.9302; 242 5.45964 12.242 11.5688;
243 3.05189 12.242 11.774; 244 5.20986 12.242 12.4126; 245 0 12.092 9.5;
246 0 12.092 10.5; 247 0 12.092 11.5; 248 0 12.092 12.5;
249 2.3694 12.092 10.2013; 250 10 12.092 9.5; 251 2.281 12.092 10.5;
252 1.985 12.092 11.5; 253 1.689 12.092 12.5; 254 2.577 12.092 9.5;
255 3.63252 12.092 9.81243; 256 2.74452 12.092 12.8124; 257 6.072 12.092 9.5;
258 10 12.092 10.5; 259 10 12.092 11.5; 260 10 12.092 12.5;
261 5.776 12.092 10.5; 262 5.48 12.092 11.5; 263 5.18399 12.092 12.5;
264 7.9125 12.092 9.5; 265 7.9125 12.092 10.5; 266 7.9125 12.092 11.5;
267 7.9125 12.092 12.5; 268 10.475 10.146 7.464; 269 11.275 10.146 7.464;
270 11.525 4.787 1.8465; 271 12.325 4.787 1.8465; 272 10.475 6.912 2.239;
273 11.275 6.912 2.239; 274 4.5785 17.7 6.75;
MEMBER INCIDENCES
1 1 13; 2 2 40; 3 3 100; 4 4 108; 5 5 101; 6 6 109; 7 13 17; 8 14 18; 9 13 202;
10 15 136; 11 16 14; 12 17 21; 13 18 22; 14 21 25; 15 22 26; 16 25 7; 17 26 8;
18 7 30; 19 8 34; 20 15 19; 21 19 23; 22 23 27; 23 27 29; 24 16 20; 25 20 24;
26 24 28; 27 17 140; 28 21 141; 29 25 142; 30 20 18; 31 24 22; 32 28 26;
33 30 31; 34 31 32; 35 32 33; 36 33 29; 37 34 38; 38 35 36; 39 36 37; 40 37 29;
41 38 39; 42 28 39; 43 39 220; 44 40 14; 45 40 120; 46 41 42; 47 43 45;
48 44 46; 49 45 106; 50 46 111; 51 43 47; 52 45 48; 53 47 145; 54 48 208;
55 49 146; 56 50 210; 57 47 48; 58 49 50; 59 9 52; 60 10 53; 61 52 54;
62 53 55; 63 54 56; 64 55 57; 65 56 58; 66 57 59; 67 58 51; 68 59 51; 69 11 60;
70 12 61; 71 60 221; 72 61 63; 73 62 64; 74 63 65; 75 64 66; 76 65 67;
77 66 68; 78 67 68; 79 69 71; 80 70 72; 81 71 73; 82 72 74; 83 73 75; 84 74 76;
85 75 11; 86 76 12; 87 69 77; 88 77 151; 89 78 152; 90 71 211; 91 75 81;
92 79 212; 93 77 79; 94 80 154; 95 78 80; 96 81 85; 97 79 83; 98 82 155;
99 80 84; 100 83 81; 101 73 83; 102 84 82; 103 74 156; 104 85 82; 105 68 85;
106 86 107; 107 88 112; 108 87 90; 109 89 91; 110 90 92; 111 91 93; 112 92 94;
113 93 95; 114 94 96; 115 95 97; 116 96 98; 117 97 98; 118 99 43; 119 13 181;
120 100 99; 121 101 69; 122 100 173; 123 43 174; 124 17 104; 125 86 105;
126 45 245; 127 7 87; 128 87 9; 129 9 176; 130 102 183; 131 103 187;
132 104 86; 133 102 104; 134 105 45; 135 103 105; 136 21 107; 137 106 9;
138 107 87; 139 106 177; 140 107 106; 141 108 110; 142 109 70; 143 108 160;
144 110 44; 145 14 182; 146 44 161; 147 18 163; 148 88 164; 149 46 250;
150 22 112; 151 8 89; 152 89 10; 153 10 162; 154 111 10; 155 112 89;
156 111 170; 157 112 111; 158 30 90; 159 90 52; 160 52 60; 161 31 92;
162 92 54; 163 54 62; 164 32 94; 165 94 56; 166 56 64; 167 33 96; 168 96 58;
169 58 66; 170 34 91; 171 91 53; 172 53 61; 173 35 93; 174 93 55; 175 55 63;
176 36 95; 177 95 57; 178 57 65; 179 37 97; 180 97 59; 181 59 67; 182 41 115;
183 42 116; 184 113 270; 185 114 271; 186 115 116; 187 119 41; 188 117 119;
189 120 119; 190 118 120; 191 118 117; 192 117 115; 193 121 186; 194 121 122;
195 122 123; 196 124 122; 197 122 126; 198 125 123; 199 123 127; 200 118 272;
201 117 273; 202 124 125; 203 126 127; 204 128 172; 205 128 129; 206 129 130;
207 131 129; 208 129 133; 209 132 130; 210 130 134; 211 131 132; 212 133 134;
213 126 268; 214 127 269; 215 135 203; 216 136 201; 217 1 137; 218 2 138;

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 49
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

219 2 139; 220 137 135; 221 138 136; 222 139 42; 223 137 13; 224 138 14;
225 139 40; 226 140 19; 227 141 23; 228 142 27; 229 13 143; 230 15 144;
231 17 141; 232 19 141; 233 21 142; 234 23 142; 235 143 140; 236 144 140;
237 143 17; 238 144 19; 239 145 49; 240 146 44; 241 3 147; 242 4 148;
243 147 145; 244 148 146; 245 147 43; 246 148 44; 247 149 209; 248 150 46;
249 47 149; 250 49 149; 251 49 150; 252 44 150; 253 151 78; 254 152 70;
255 5 157; 256 6 158; 257 153 213; 258 154 72; 259 155 76; 260 156 84;
261 157 151; 262 158 152; 263 157 69; 264 158 70; 265 77 153; 266 78 153;
267 78 154; 268 70 154; 269 80 156; 270 72 156; 271 84 155; 272 74 155;
273 159 121; 274 160 109; 275 161 70; 276 162 12; 277 2 167; 278 4 168;
279 4 160; 280 6 160; 281 108 161; 282 109 161; 283 111 162; 284 74 162;
285 18 112; 286 46 112; 287 22 89; 288 111 89; 289 163 88; 290 164 46;
291 14 165; 292 110 166; 293 165 163; 294 166 164; 295 165 18; 296 166 46;
297 167 159; 298 168 159; 299 167 14; 300 168 110; 301 169 74; 302 170 169;
303 171 258; 304 170 171; 305 172 259; 306 169 172; 307 173 101; 308 174 69;
309 175 247; 310 176 11; 311 177 73; 312 3 173; 313 5 173; 314 100 174;
315 101 174; 316 43 175; 317 69 175; 318 45 177; 319 71 177; 320 106 176;
321 73 176; 322 106 87; 323 21 87; 324 45 107; 325 17 107; 326 178 185;
327 1 179; 328 3 180; 329 179 178; 330 180 178; 331 179 13; 332 180 99;
333 181 102; 334 182 184; 335 183 178; 336 184 159; 337 185 103; 338 186 188;
339 187 99; 340 188 110; 341 181 199; 342 183 189; 343 185 190; 344 187 195;
345 189 191; 346 190 192; 347 191 193; 348 192 194; 349 193 205; 350 194 206;
351 193 194; 352 195 196; 353 190 195; 354 196 197; 355 192 196; 356 197 207;
357 194 197; 358 198 200; 359 191 198; 360 199 198; 361 189 199; 362 200 204;
363 193 200; 364 201 16; 365 200 201; 366 202 135; 367 199 202; 368 203 15;
369 198 203; 370 204 182; 371 16 204; 372 205 184; 373 204 205; 374 206 186;
375 205 206; 376 207 188; 377 206 207; 378 208 149; 379 209 50; 380 210 150;
381 211 79; 382 212 153; 383 213 80; 384 213 263; 385 212 256; 386 211 253;
387 214 233; 388 215 234; 389 216 255; 390 217 261; 391 218 274; 392 218 221;
393 219 220; 394 220 35; 395 221 62; 396 219 222; 397 189 227; 398 190 228;
399 191 229; 400 192 230; 401 223 231; 402 224 232; 403 227 223; 404 228 224;
405 229 231; 406 230 232; 407 225 226; 408 227 228; 409 229 230; 410 227 229;
411 228 230; 412 231 225; 413 232 226; 414 233 216; 415 234 262; 416 233 241;
417 234 242; 418 214 243; 419 215 244; 420 239 235; 421 240 236; 422 237 239;
423 238 240; 424 241 239; 425 242 240; 426 243 237; 427 244 238; 428 243 241;
429 244 242; 430 243 244; 431 241 242; 432 235 236; 433 245 246; 434 246 175;
435 247 248; 436 248 71; 437 249 254; 438 250 171; 439 245 254; 440 246 251;
441 247 252; 442 248 253; 443 251 249; 444 252 251; 445 253 252; 446 254 208;
447 255 209; 448 254 255; 449 251 233; 450 252 214; 451 256 214; 452 253 256;
453 257 210; 454 257 264; 455 258 128; 456 259 260; 457 260 72; 458 261 257;
459 262 217; 460 261 265; 461 262 266; 462 263 215; 463 263 267; 464 150 264;
465 264 250; 466 265 258; 467 266 259; 468 267 260; 469 267 154; 470 266 267;
471 265 266; 472 264 265; 473 268 131; 474 269 132; 475 270 115; 476 271 116;
477 272 124; 478 273 125; 479 274 219;
DEFINE PMEMBER
126 433 434 PMEMBER 1
START GROUP DEFINITION
MEMBER
_COL 1 TO 8 12 TO 17 44 47 TO 50 79 TO 86 118 120 121 137 141 142 144 154
END GROUP DEFINITION
SUPPORTS
*1 TO 14 17 18 21 22 25 26 40 43 TO 46 69 TO 76 99 TO 101 106 108 TO 111 189 -
*190 TO 192 214 215 223 TO 244 PINNED
113 114 FIXED BUT FX FZ MX MY MZ
1 TO 6 FIXED BUT MX
MEMBER OFFSET
408 START -0.174 0 0
408 END -0.174 0 0
DEFINE MATERIAL START
ISOTROPIC STEEL
E 2.05e+008
POISSON 0.3
DENSITY 76.8195
ALPHA 1.2e-005

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 50
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

DAMP 0.03
TYPE STEEL
STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
END DEFINE MATERIAL
MEMBER PROPERTY JINDAL
1 2 7 8 12 TO 17 44 TABLE ST UC305X305X96.9
3 4 47 TO 50 118 120 137 141 144 154 TABLE ST UC305X305X96.9
5 6 79 TO 86 121 142 TABLE ST UC305X305X96.9
MEMBER PROPERTY INDIAN
196 TO 199 202 203 TABLE ST ISMC250
MEMBER PROPERTY JINDAL
194 195 TABLE ST UB203X133X25
384 385 387 TO 390 414 415 447 451 453 458 459 462 TABLE ST UB533X210X82
386 437 443 TO 446 TABLE ST UB457X191X67
124 125 132 134 147 148 289 290 TABLE ST UB457X191X67
MEMBER PROPERTY INDIAN
207 TO 212 TABLE ST ISMC250
MEMBER PROPERTY JINDAL
205 206 TABLE ST UB203X133X30
27 TO 32 101 103 226 TO 228 260 TABLE ST UB254X146X37
20 TO 26 42 93 95 97 99 100 102 105 TABLE ST UB254X146X37
18 19 33 TO 41 43 59 TO 78 108 TO 117 394 395 TABLE ST UB305X165X40
392 393 TABLE ST UB254X146X37
217 218 220 221 255 256 261 262 TABLE ST UC152X152X23
MEMBER PROPERTY INDIAN
225 237 238 TABLE ST ISMC125
219 222 229 230 235 236 TABLE ST ISMC150
MEMBER PROPERTY JINDAL
45 46 187 189 TABLE ST UB203X133X25
241 TO 244 TABLE ST UC152X152X23
MEMBER PROPERTY INDIAN
245 246 299 TABLE ST ISMC125
MEMBER PROPERTY JINDAL
57 58 TABLE ST UB203X133X25
51 53 55 239 240 TABLE ST UB305X165X40
91 96 98 104 259 TABLE ST UB305X165X40
87 TO 89 253 254 TABLE ST UB305X165X40
277 278 283 TO 288 297 298 320 TO 325 327 TO 330 TABLE ST UC152X152X23
MEMBER PROPERTY INDIAN
291 TO 294 TABLE ST ISMC150
318 319 TABLE ST ISMC150
MEMBER PROPERTY JINDAL
107 136 139 140 155 311 TABLE ST UB254X146X37
127 TO 129 310 TABLE ST UB305X165X40
106 133 135 138 143 146 274 275 TABLE ST UB254X146X37
122 123 307 308 TABLE ST UB254X146X37
MEMBER PROPERTY INDIAN
295 296 300 331 332 TABLE ST ISMC125
MEMBER PROPERTY JINDAL
304 306 TABLE ST UB203X133X25
150 156 157 301 302 TABLE ST UB305X165X40
151 TO 153 276 TABLE ST UB305X165X40
MEMBER PROPERTY INDIAN
158 TO 181 TABLE ST ISMC150
MEMBER PROPERTY JINDAL
391 396 479 TABLE ST UB457X191X82
MEMBER PROPERTY INDIAN
184 185 200 201 213 214 473 TO 478 TABLE ST ISMC250
MEMBER PROPERTY JINDAL
182 183 186 188 190 TO 192 TABLE ST UB203X133X25
397 TO 407 412 413 TABLE ST UC254X254X73.1
MEMBER PROPERTY INDIAN
409 TO 411 TABLE ST ISMC150
408 TABLE ST ISMC150

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 51
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

428 TO 431 TABLE ST ISMC150


MEMBER PROPERTY JINDAL
416 TO 427 432 TABLE ST UC254X254X73.1
MEMBER PROPERTY INDIAN
439 TO 442 454 460 461 463 465 TO 468 TABLE ST ISMC150
MEMBER PROPERTY JINDAL
448 TO 450 452 TABLE ST UB203X133X25
231 TO 234 249 TO 252 265 TO 272 TABLE ST UC152X152X23
464 469 TO 472 TABLE ST UB203X133X30
MEMBER PROPERTY JINDAL
342 343 345 TO 350 372 374 TAPERED 0.5 0.012 0.5 0.3 0.025 0.3 0.025
119 130 131 145 193 273 326 333 TO 339 -
340 TAPERED 0.6 0.012 0.6 0.3 0.025 0.3 0.025
MEMBER PROPERTY INDIAN
341 358 360 TABLE ST ISMC150
359 361 367 369 371 373 375 TABLE ST ISMC200
MEMBER PROPERTY JINDAL
351 362 363 365 370 TABLE ST UB457X191X67
MEMBER PROPERTY JINDAL
9 TO 11 215 216 344 352 354 356 364 366 368 -
376 TAPERED 0.5 0.012 0.5 0.3 0.025 0.3 0.025
MEMBER PROPERTY JINDAL
279 TO 282 312 TO 317 TABLE ST UC152X152X23
MEMBER PROPERTY JINDAL
52 54 56 90 92 94 247 248 257 258 378 TO 382 -
383 TAPERED 0.5 0.012 0.5 0.3 0.016 0.3 0.016
MEMBER PROPERTY JINDAL
353 355 357 377 TABLE ST UB203X133X25
MEMBER PROPERTY INDIAN
223 224 263 264 TABLE ST ISMC125
MEMBER PROPERTY INDIAN
126 149 204 303 305 309 433 TO 436 438 455 TO 456 -
457 TAPERED 0.5 0.012 0.5 0.25 0.016 0.25 0.016
CONSTANTS
MATERIAL STEEL ALL
*************************************************************************************
MEMBER RELEASE
341 TO 344 START MX MY
370 372 374 376 END MX MY
351 353 355 357 359 361 363 371 373 375 377 START MX MY
351 353 355 357 365 367 369 371 373 375 377 END MX MY
439 TO 442 448 TO 450 452 454 460 461 463 465 TO 468 START MY MZ
439 TO 442 448 TO 450 452 454 460 461 463 465 TO 468 END MY MZ
384 TO 386 464 START MY MZ
446 447 453 469 END MY MZ
217 TO 219 223 TO 225 229 TO 234 237 START MY MZ
220 TO 225 231 TO 238 END MY MZ
241 242 245 246 249 TO 252 START MY MZ
243 TO 246 249 TO 252 END MY MZ
255 256 263 TO 272 START MY MZ
261 TO 272 END MY MZ
312 TO 325 327 328 331 332 START MY MZ
312 TO 325 329 TO 332 END MY MZ
277 TO 288 291 292 295 296 299 300 START MY MZ
279 TO 288 293 TO 300 END MY MZ
341 END MX MY
362 START MX MY
360 START MX MY
360 END MX MY
358 START MX MY
358 END MX MY
DEFINE 1893 LOAD
ZONE 0.1 RF 1 I 1 SS 1 DM 0.02
JOINT WEIGHT

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 52
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

1 WEIGHT 47.13
2 WEIGHT 56.54
3 WEIGHT 46.75
4 WEIGHT 49.15
5 WEIGHT 19.54
6 WEIGHT 13.86
7 WEIGHT 15.03
8 WEIGHT 13.32
9 WEIGHT 36.79
10 WEIGHT 36.49
11 WEIGHT 20.71
12 WEIGHT 15.43
13 WEIGHT 50.14
14 WEIGHT 63.38
17 WEIGHT 39.81
18 WEIGHT 21.9
21 WEIGHT 31.01
22 WEIGHT 20.1
25 WEIGHT 6.54
26 WEIGHT 9.75
40 WEIGHT 24.74
43 WEIGHT 23.62
44 WEIGHT 44.07
45 WEIGHT 56.09
46 WEIGHT 37.48
69 WEIGHT 27.72
70 WEIGHT 32
71 WEIGHT 46.94
72 WEIGHT 41.85
73 WEIGHT 18.42
74 WEIGHT 27.88
75 WEIGHT 14
76 WEIGHT 6.54
99 WEIGHT 31.66
100 WEIGHT 10.06
101 WEIGHT 10.95
106 WEIGHT 25.14
108 WEIGHT 9.89
109 WEIGHT 10.83
110 WEIGHT 39.72
111 WEIGHT 23.63
189 WEIGHT 23.2
190 WEIGHT 30.9
191 WEIGHT 102.93
192 WEIGHT 83.35
214 WEIGHT 47.9
215 WEIGHT 70.82
223 WEIGHT 1.38
224 WEIGHT 1.37
225 WEIGHT 1.1
226 WEIGHT 0.93
227 WEIGHT 0.09
228 WEIGHT 0.24
229 WEIGHT 23.45
230 WEIGHT 4.34
231 WEIGHT 42.52
232 WEIGHT 7.93
233 WEIGHT 25.25
234 WEIGHT 17.74
235 WEIGHT 1.1
236 WEIGHT 1
237 WEIGHT 0.66
238 WEIGHT 0.59
239 WEIGHT 31.1

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 53
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

240 WEIGHT 8.79


241 WEIGHT 14.04
242 WEIGHT 4.09
243 WEIGHT 0.48
244 WEIGHT 0.84
***********************************************************************
LOAD 9 SEISMIC LOAD +X
1893 LOAD X 1
PERFORM ANALYSIS
CHANGE
**********************************************************************
LOAD 10 SEISMIC LOAD +Z
1893 LOAD Z 1
PERFORM ANALYSIS
CHANGE
***********************************************************************
LOAD 1 DEAD LOAD
SELFWEIGHT Y -1
***** FLOOR LOAD
ONEWAY LOAD
YRANGE 8.2 8.2 ONE -0.3 XRANGE 0 10 ZRANGE 0 1.485 GY
YRANGE 8.2 8.2 ONE -0.3 XRANGE 0 10 ZRANGE 1.485 2.875 GY
YRANGE 8.2 8.2 ONE -0.3 XRANGE 0 10 ZRANGE 2.875 5.125 GY
YRANGE 8.2 8.2 ONE -0.3 XRANGE 0 10 ZRANGE 5.125 7.63 GY
YRANGE 12.092 12.092 ONE -0.3 XRANGE 0 10 ZRANGE 8.5 13.5 GY
**** STAIRCASE LOAD
ONEWAY LOAD
YRANGE 8.2 8.2 ONE -0.3 XRANGE 10.475 11.275 ZRANGE 3.878 4.788 GY
YRANGE 12.092 12.092 ONE -0.3 XRANGE 10.475 11.275 ZRANGE 10.14 11.125 GY
MEMBER LOAD
184 185 200 201 213 214 473 TO 478 UNI GY -0.135
JOINT LOAD
13 14 16 69 70 99 110 201 TO 203 FY -1.4
****ROOF SHEETING LOAD
MEMBER LOAD
18 33 TO 36 UNI GY -0.55
108 110 112 114 116 UNI GY -1.11
59 61 63 65 67 UNI GY -1.2
69 71 73 75 77 395 UNI GY -0.65
19 37 TO 41 43 394 UNI GY -0.55
109 111 113 115 117 UNI GY -1.11
60 62 64 66 68 UNI GY -1.2
70 72 74 76 78 UNI GY -0.65
**** WALL CLADDING LOAD
MEMBER LOAD
1 7 12 14 16 UNI GY -1.8
2 8 13 15 17 44 UNI GY -1.8
3 5 47 49 79 81 83 85 118 120 121 137 UNI GY -1.8
4 6 48 50 80 82 84 86 141 142 144 154 UNI GY -1.8
1 7 12 14 16 UNI GY -0.77
3 47 49 118 120 137 UNI GY -1.22
5 79 81 83 85 121 UNI GY -0.45
2 8 13 15 17 44 UNI GY -0.77
4 48 50 141 144 154 UNI GY -1.22
6 80 82 84 86 142 UNI GY -0.45
****LOAD OF SRC-01 CONV
MEMBER LOAD
335 CON GY -10.14 0.1
326 CON GY -10.14 0.775
342 343 UNI GY -5.524
****LOAD OF CV-08 CONV
MEMBER LOAD
382 CON GY -21.04 0.11
257 CON GY -21.04 1.065

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 54
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

384 385 451 462 UNI GY -11.043


***********************************************************************
LOAD 2 EQUIPMENT LOAD
*** LOAD CONSIDERED ON TRANSFER TOWER
JOINT LOAD
191 TO 194 FY -15.04
209 210 216 217 FY -15.04
****LOAD OF SRC-01 CONV
MEMBER LOAD
335 CON GY -5.538 0.1
326 CON GY -5.538 0.775
342 343 UNI GY -2.005
****LOAD OF CV-08 CONV
MEMBER LOAD
382 CON GY -10.601 0.11
257 CON GY -10.601 1.065
384 385 451 462 UNI GY -1.92
**** LOAD OF HEAD FRAME SRC-01 CONV
405 CON GY -61 0.791
406 CON GY -8.5 0.791
362 CON GY -52.5 1.24
405 406 CMOM GZ 3.332 0.791
405 406 CON GY -2.75 0.791
405 406 CMOM GZ -0.776 0.791
405 CMOM GX 71.66 0.791
**** LOAD OF HEAD FRAME CV-08 CONV
424 CON GY -41 0.792
425 CON GY -8.5 0.792
424 425 CON GY -2.75 0.792
424 425 CMOM GX -3.315 0.792
424 425 CMOM GX -0.776 0.792
424 CMOM GZ 35.75 0.792
445 CON GY -32.5 0.5
***********************************************************************
LOAD 3 MATERIAL LOAD
****LOAD OF SRC-01 CONV
MEMBER LOAD
335 CON GY -2.969 0.1
326 CON GY -2.969 0.775
342 343 UNI GY -1.075
****LOAD OF CV-08 CONV
MEMBER LOAD
382 CON GY -5.936 0.11
257 CON GY -5.936 1.065
384 385 451 462 UNI GY -1.075
***********************************************************************
LOAD 4 LIVE LOAD
***** FLOOR LOAD
ONEWAY LOAD
YRANGE 8.2 8.2 ONE -5 XRANGE 0 10 ZRANGE 0 1.485 GY
YRANGE 8.2 8.2 ONE -5 XRANGE 0 10 ZRANGE 1.485 2.875 GY
YRANGE 8.2 8.2 ONE -5 XRANGE 0 10 ZRANGE 2.875 5.125 GY
YRANGE 8.2 8.2 ONE -5 XRANGE 0 10 ZRANGE 5.125 7.63 GY
YRANGE 12.092 12.092 ONE -5 XRANGE 0 10 ZRANGE 8.5 13.5 GY
**** STAIRCASE LOAD
ONEWAY LOAD
YRANGE 8.2 8.2 ONE -2.5 XRANGE 10.475 11.275 ZRANGE 3.878 4.788 GY
YRANGE 12.092 12.092 ONE -2.5 XRANGE 10.475 11.275 ZRANGE 10.14 11.125 GY
MEMBER LOAD
184 185 200 201 213 214 473 TO 478 UNI GY -1.125
****ROOF SHEETING LOAD
MEMBER LOAD
18 33 TO 36 UNI GY -2.13
108 110 112 114 116 UNI GY -4.25

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 55
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

59 61 63 65 67 UNI GY -4.63
69 71 73 75 77 395 UNI GY -2.5
19 37 TO 41 43 394 UNI GY -2.13
109 111 113 115 117 UNI GY -4.25
60 62 64 66 68 UNI GY -4.63
70 72 74 76 78 UNI GY -2.5
****LOAD OF SRC-01 CONV
MEMBER LOAD
335 CON GY -6.905 0.1
326 CON GY -6.905 0.775
****LOAD OF CV-08 CONV
MEMBER LOAD
382 CON GY -11.043 0.11
257 CON GY -11.043 1.065
***********************************************************************
LOAD 5 WINDLOAD +X
MEMBER LOAD
1 7 12 14 16 UNI GX 2.88
3 47 49 118 120 137 UNI GX 4.57
5 79 81 83 85 121 UNI GX 1.69
2 8 13 15 17 44 UNI GX 1.03
4 48 50 141 144 154 UNI GX 1.63
6 80 82 84 86 142 UNI GX 0.61
1 2 7 8 12 TO 17 44 UNI GZ -2.9
5 6 79 TO 86 121 142 UNI GZ 2.9
****ROOF SHEETING LOAD
MEMBER LOAD
18 33 TO 36 UNI GY 1.77
108 110 112 114 116 UNI GY 3.54
59 61 63 65 67 UNI GY 3.85
69 71 73 75 77 395 UNI GY 1.69
19 37 TO 41 43 394 UNI GY 1.11
109 111 113 115 117 UNI GY 2.22
60 62 64 66 68 UNI GY 2.42
70 72 74 76 78 UNI GY 1.21
****HEAD CHUTE
JOINT LOAD
191 TO 194 FX 0.78
****LOAD OF CV-08 CONV
MEMBER LOAD
382 CON GY 9.2913 0.11
257 CON GY -5.693 1.065
382 CON GX 6.319 0.11
257 CON GX 5.321 1.065
***********************************************************************
LOAD 6 WINDLOAD -X
MEMBER LOAD
1 7 12 14 16 UNI GX -1.03
3 47 49 118 120 137 UNI GX -1.63
5 79 81 83 85 121 UNI GX -0.61
2 8 13 15 17 44 UNI GX -2.88
4 48 50 141 144 154 UNI GX -4.57
6 80 82 84 86 142 UNI GX -1.69
1 2 7 8 12 TO 17 44 UNI GZ -2.9
5 6 79 TO 86 121 142 UNI GZ 2.9
****ROOF SHEETING LOAD
MEMBER LOAD
18 33 TO 36 UNI GY 1.11
108 110 112 114 116 UNI GY 2.22
59 61 63 65 67 UNI GY 2.42
69 71 73 75 77 395 UNI GY 1.21
19 37 TO 41 43 394 UNI GY 1.77
109 111 113 115 117 UNI GY 3.54
60 62 64 66 68 UNI GY 3.85

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 56
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

70 72 74 76 78 UNI GY 1.69
****HEAD CHUTE
JOINT LOAD
191 TO 194 FX -0.78
****LOAD OF CV-08 CONV
MEMBER LOAD
382 CON GY -5.693 0.11
257 CON GY 9.2913 1.065
382 CON GX -5.321 0.11
257 CON GX -6.319 1.065
***********************************************************************
LOAD 7 WINDLOAD +Z
MEMBER LOAD
1 2 7 8 12 TO 17 44 UNI GZ 3.39
3 TO 6 47 TO 50 79 TO 86 118 120 121 137 141 142 144 154 UNI GZ 1.21
1 7 12 14 16 UNI GX -2.47
3 47 49 118 120 137 UNI GX -3.92
5 79 81 83 85 121 UNI GX -1.45
2 8 13 15 17 44 UNI GX 2.47
4 48 50 141 144 154 UNI GX 3.92
6 80 82 84 86 142 UNI GX 1.45
****HEAD CHUTE
JOINT LOAD
191 TO 194 FZ 1.27
****LOAD OF SRC-01 CONV
MEMBER LOAD
335 CON GY 2.7401 0.1
326 CON GY -2.7401 0.775
335 CON GZ 6.289 0.1
326 CON GZ 1.1 0.775
***********************************************************************
LOAD 8 WINDLOAD -Z
MEMBER LOAD
1 2 7 8 12 TO 17 44 UNI GZ -1.21
3 TO 6 47 TO 50 79 TO 86 118 120 121 137 141 142 144 154 UNI GZ -3.39
1 7 12 14 16 UNI GX -2.47
3 47 49 118 120 137 UNI GX -3.92
5 79 81 83 85 121 UNI GX -1.45
2 8 13 15 17 44 UNI GX 2.47
4 48 50 141 144 154 UNI GX 3.92
6 80 82 84 86 142 UNI GX 1.45
****HEAD CHUTE
JOINT LOAD
191 TO 194 FZ -1.27
****LOAD OF SRC-01 CONV
MEMBER LOAD
335 CON GY -2.7401 0.1
326 CON GY 2.7401 0.775
335 CON GZ -1.1 0.1
326 CON GZ -6.289 0.775
***********************************************************************
LOAD 11 BELT TENSION
JOINT LOAD
231 232 FX -130.7
JOINT LOAD
239 240 FZ 44.9
***********************************************************************
LOAD 12 MONO RAIL LOAD
JOINT LOAD
7 TO 12 FY -8.33
***********************************************************************
LOAD 13 MATERIAL JAM LOAD
JOINT LOAD
191 TO 194 FY -12.68

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 57
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

209 210 216 217 FY -34.56


*******************************************************************************
********AS PER IS800 2007 LOAD COMBINATIONS FOR LIMIT STATE OF COLLAPSE*******
LOAD COMB 220 (1.5DL + 1.5EQUIP + 1.5LL + 1.5ML + 1.5BT)
1 1.5 2 1.5 3 1.5 4 1.5 11 1.5
LOAD COMB 221 (1.5DL + 1.5EQUIP + 1.5LL + 1.5 MR)
1 1.5 2 1.5 4 1.5 12 1.5
LOAD COMB 222 (1.5DL + 1.5EQUIP + 0.6LL + 1.5 MJ)
1 1.5 2 1.5 4 0.6 13 1.5
LOAD COMB 223 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (X-) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 5 1.2
LOAD COMB 224 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (-X) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 6 1.2
LOAD COMB 225 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (Z) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 7 1.2
LOAD COMB 226 (1.2DL + 1.2EQUIP + 1.2LL + 1.2ML + 1.2BT + 1.2WIND IN (-Z) DIR)
1 1.2 2 1.2 3 1.2 4 1.2 11 1.2 8 1.2
LOAD COMB 227 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (X) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 9 1.2
LOAD COMB 228 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (-X) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 9 -1.2
LOAD COMB 229 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (Z) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 10 1.2
LOAD COMB 230 (1.2DL + 1.2EQUIP + 0.6LL + 1.2ML + 1.2BT + 1.2SL IN (-Z) DIR)
1 1.2 2 1.2 3 1.2 4 0.6 11 1.2 10 -1.2
LOAD COMB 231 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (X) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 5 1.2
LOAD COMB 232 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (-X) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 6 1.2
LOAD COMB 233 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (Z) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 7 1.2
LOAD COMB 234 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MR + 1.2WIND IN (-Z) DIR)
1 1.2 2 1.2 4 1.2 12 1.2 8 1.2
LOAD COMB 235 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (X) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 9 1.2
LOAD COMB 236 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (-X) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 9 -1.2
LOAD COMB 237 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (Z) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 10 1.2
LOAD COMB 238 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MR + 1.2SL IN (-Z) DIR)
1 1.2 2 1.2 4 0.6 12 1.2 10 -1.2
LOAD COMB 239 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (X) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 5 1.2
LOAD COMB 240 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (-X) DIR )
1 1.2 2 1.2 4 1.2 13 1.2 6 1.2
LOAD COMB 241 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (Z) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 7 1.2
LOAD COMB 242 (1.2DL + 1.2EQUIP + 1.2LL + 1.2MJ + 1.2WIND IN (-Z) DIR)
1 1.2 2 1.2 4 1.2 13 1.2 8 1.2
LOAD COMB 243 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (X) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 9 1.2
LOAD COMB 244 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (-X) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 9 -1.2
LOAD COMB 245 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (Z) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 10 1.2
LOAD COMB 246 (1.2DL + 1.2EQUIP + 0.6LL + 1.2MJ + 1.2SL IN (-Z) DIR)
1 1.2 2 1.2 4 0.6 13 1.2 10 -1.2
*** 0.9 DL + 1.5WL/1.5SL
LOAD COMB 247 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (X) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 5 1.5
LOAD COMB 248 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (-X) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 6 1.5
LOAD COMB 249 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (Z) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 7 1.5

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 58
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

LOAD COMB 250 (0.9DL + 0.9EQUIP + 0.9ML + 1.5BT + 1.5WIND IN (-Z) DIR)
1 0.9 2 0.9 3 0.9 11 1.5 8 1.5
LOAD COMB 251 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (X) DIR)
1 0.9 2 0.9 12 0.9 5 1.5
LOAD COMB 252 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (-X) DIR)
1 0.9 2 0.9 12 0.9 6 1.5
LOAD COMB 253 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (Z) DIR)
1 0.9 2 0.9 12 0.9 7 1.5
LOAD COMB 254 (0.9DL + 0.9EQUIP + 0.9MR + 1.5WIND IN (-Z) DIR)
1 0.9 2 0.9 12 0.9 8 1.5
LOAD COMB 255 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (X) DIR)
1 0.9 2 0.9 13 0.9 5 1.5
LOAD COMB 256 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (-X) DIR)
1 0.9 2 0.9 13 0.9 6 1.5
LOAD COMB 257 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (Z) DIR)
1 0.9 2 0.9 13 0.9 7 1.5
LOAD COMB 258 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5WIND IN (-Z) DIR)
1 0.9 2 0.9 13 0.9 8 1.5
LOAD COMB 259 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (X) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 9 1.5
LOAD COMB 260 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (-X) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 9 -1.5
LOAD COMB 261 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (Z) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 10 1.5
LOAD COMB 262 (0.9DL + 0.9EQUIP + 0.9ML + 0.9BT + 1.5SL IN (-Z) DIR)
1 0.9 2 0.9 3 0.9 11 0.9 10 -1.5
LOAD COMB 263 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (X) DIR)
1 0.9 2 0.9 12 0.9 9 1.5
LOAD COMB 264 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (-X) DIR)
1 0.9 2 0.9 12 0.9 9 -1.5
LOAD COMB 265 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (Z) DIR)
1 0.9 2 0.9 12 0.9 10 1.5
LOAD COMB 266 (0.9DL + 0.9EQUIP + 0.9MR + 1.5SL IN (-Z) DIR)
1 0.9 2 0.9 12 0.9 10 -1.5
LOAD COMB 267 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (X) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 9 1.5
LOAD COMB 268 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (-X) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 9 -1.5
LOAD COMB 269 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (Z) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 10 1.5
LOAD COMB 270 (0.9DL + 0.9EQUIP + 0.9MJ + 1.5BT + 1.5SL IN (-Z) DIR)
1 0.9 2 0.9 13 0.9 11 1.5 10 -1.5
**** 1.5 DL+1.5WL/SL
LOAD COMB 271 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 5 1.5
LOAD COMB 272 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (-X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 6 1.5
LOAD COMB 273 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 7 1.5
LOAD COMB 274 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5WIND IN (-Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 8 1.5
LOAD COMB 275 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 9 1.5
LOAD COMB 276 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (-X) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 9 -1.5
LOAD COMB 277 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 10 1.5
LOAD COMB 278 (1.5DL + 1.5EQUIP + 1.5ML + 1.5BT + 1.5SL IN (-Z) DIR)
1 1.5 2 1.5 3 1.5 11 1.5 10 -1.5
LOAD COMB 279 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (X) DIR)
1 1.5 2 1.5 12 1.5 5 1.5
LOAD COMB 280 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (-X) DIR)
1 1.5 2 1.5 12 1.5 6 1.5
LOAD COMB 281 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (Z) DIR)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 59
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

1 1.5 2 1.5 12 1.5 7 1.5


LOAD COMB 282 (1.5DL + 1.5EQUIP + 1.5MR + 1.5WIND IN (-Z) DIR)
1 1.5 2 1.5 12 1.5 8 1.5
LOAD COMB 283 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SLQ IN (X) DIR)
1 1.5 2 1.5 12 1.5 9 1.5
LOAD COMB 284 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SL IN (-X) DIR)
1 1.5 2 1.5 12 1.5 9 -1.5
LOAD COMB 285 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SL IN (Z) DIR)
1 1.5 2 1.5 12 1.5 10 1.5
LOAD COMB 286 (1.5DL + 1.5EQUIP + 1.5MR + 1.5SL IN (-Z) DIR)
1 1.5 2 1.5 12 1.5 10 -1.5
LOAD COMB 287 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5WIND IN (X) DIR)
1 1.5 2 1.5 13 1.5 5 1.5
LOAD COMB 288 (1.5DL + 1.5EQUIP + 1.5MJ +1.5WIND IN (-X) DIR)
1 1.5 2 1.5 13 1.5 6 1.5
LOAD COMB 289 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5WIND IN (Z) DIR)
1 1.5 2 1.5 13 1.5 7 1.5
LOAD COMB 290 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5WIND IN (-Z) DIR)
1 1.5 2 1.5 13 1.5 8 1.5
LOAD COMB 291 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SLQ IN (X) DIR)
1 1.5 2 1.5 13 1.5 9 1.5
LOAD COMB 292 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SL IN (-X) DIR)
1 1.5 2 1.5 13 1.5 9 -1.5
LOAD COMB 293 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SL IN (Z) DIR)
1 1.5 2 1.5 13 1.5 10 1.5
LOAD COMB 294 (1.5DL + 1.5EQUIP + 1.5MJ + 1.5SL IN (-Z) DIR)
1 1.5 2 1.5 13 1.5 10 -1.5
**********AS PER IS800 2007 LOAD COMBINTIONS FOR LIMIT STATE OF SERVICEABILITY*****
LOAD COMB 295 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0
LOAD COMB 296 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR)
1 1.0 2 1.0 4 1.0 12 1.0
LOAD COMB 297 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ)
1 1.0 2 1.0 4 1.0 13 1.0
LOAD COMB 298 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 5 1.0
LOAD COMB 299 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (-X)DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 6 1.0
LOAD COMB 300 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (Z)DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 7 1.0
LOAD COMB 301 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0WIND IN (-Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 8 1.0
LOAD COMB 302 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 9 1.0
LOAD COMB 303 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (-X) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 9 -1.0
LOAD COMB 304 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 10 1.0
LOAD COMB 305 (1.0DL + 1.0EQUIP + 1.0LL + 1.0ML + 1.0BT + 1.0SL IN (-Z) DIR)
1 1.0 2 1.0 3 1.0 4 1.0 11 1.0 10 -1.0
LOAD COMB 306 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 5 1.0
LOAD COMB 307 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (-X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 6 1.0
LOAD COMB 308 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 7 1.0
LOAD COMB 309 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0WIND IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 8 1.0
LOAD COMB 310 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 9 1.0
LOAD COMB 311 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (-X) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 9 -1.0
LOAD COMB 312 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 10 1.0

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 60
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

LOAD COMB 313 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MR + 1.0SL IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 12 1.0 10 -1.0
LOAD COMB 314 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 5 1.0
LOAD COMB 315 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (-X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 6 1.0
LOAD COMB 316 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 7 1.0
LOAD COMB 317 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0WIND IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 8 1.0
LOAD COMB 318 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 9 1.0
LOAD COMB 319 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (-X) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 9 -1.0
LOAD COMB 320 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 10 1.0
LOAD COMB 321 (1.0DL + 1.0EQUIP + 1.0LL + 1.0MJ + 1.0SL IN (-Z) DIR)
1 1.0 2 1.0 4 1.0 13 1.0 10 -1.0
***************************************************************************
LOAD COMB 500 DL+EL+0.5LL+ML
1 1.0 2 1.0 3 1.0 4 0.5
***********************************************************************
PERFORM ANALYSIS PRINT ALL
LOAD LIST 220 TO 321
PARAMETER 1
CODE IS800 LSD
FU 410000 ALL
FYLD 250000 ALL
LZ 8.5 MEMB 119 130 131 326 333 335 337 339
LZ 8.5 MEMB 145 193 273 334 336 338 340
LX 10 MEMB 344 352 354 356 376
LX 10 MEMB 343 346 348 350 374
LX 10 MEMB 342 345 347 349 372
LX 10 MEMB 9 TO 11 215 216 364 366 368
LX 10 MEMB 52 54 56 247 248 378 TO 380
LX 10 MEMB 90 92 94 257 258 381 TO 383
LZ 5 MEMB 126 309 433 TO 436
LZ 5 MEMB 149 204 303 305 438 455 TO 457
LZ 8.5 MEMB 124 125 132 134
LZ 8.5 MEMB 147 148 289 290
LZ 5.21 MEMB 384 388 390 415 453 458 459 462
LZ 5.21 MEMB 385 387 389 414 447 451
LZ 5.21 MEMB 386 437 443 TO 446
LZ 5 MEMB 123 146 275 308
LZ 8.5 MEMB 136 140 150 157
MAIN 250 MEMB 184 185 200 201 213 214 473 TO 478
MAIN 250 MEMB 283 TO 288 320 TO 325
MAIN 250 MEMB 231 TO 234 251 252 267 TO 272
MAIN 250 MEMB 158 TO 181
RATIO 1 ALL
CHECK CODE ALL
STEEL TAKE OFF ALL
FINISH

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 61
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

4.3 DESIGN OF MEMBERS- STAAD OUTPUT

STAAD.PRO CODE CHECKING - IS-800 2007(LSD) (V2.0)


*****************************************************
|----------------------------------------------------------------------------------|
| Member Number: 1 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.307 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 2 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.218 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 3 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.538 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 4 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.496 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 5 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.400 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 6 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.331 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 7 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.281 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 8 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.281 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 9 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.883 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 10 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.290 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 11 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.973 Critical Load Case: 268 Location: 2.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 12 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 62
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 13 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 14 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 15 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 16 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.107 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 17 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.058 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 18 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.264 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 19 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.239 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 20 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.622 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 21 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 22 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 23 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.387 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 24 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.622 Critical Load Case: 233 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 25 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 63
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.399 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 26 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 27 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 28 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 29 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 227 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 30 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.319 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 31 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.319 Critical Load Case: 224 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 32 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.319 Critical Load Case: 235 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 33 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 34 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 35 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 36 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.118 Critical Load Case: 220 Location: 0.26 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 37 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.113 Critical Load Case: 276 Location: 0.40 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 38 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 64
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |


| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 39 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.199 Critical Load Case: 276 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 40 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.216 Critical Load Case: 276 Location: 0.26 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 41 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.188 Critical Load Case: 276 Location: 0.45 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 42 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.232 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 43 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.242 Critical Load Case: 276 Location: 0.20 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 44 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.228 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 45 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.365 Critical Load Case: 220 Location: 0.47 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 46 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.076 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 47 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 291 Location: 2.44 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 48 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.344 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 49 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.468 Critical Load Case: 292 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 50 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.464 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 65
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 51 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.596 Critical Load Case: 268 Location: 1.60 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 52 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.541 Critical Load Case: 267 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 53 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.783 Critical Load Case: 268 Location: 1.51 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 54 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.378 Critical Load Case: 267 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 55 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 291 Location: 1.46 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 56 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 269 Location: 0.54 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 57 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.488 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 58 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.838 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 59 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.672 Critical Load Case: 303 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 60 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.720 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 61 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.322 Critical Load Case: 292 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 62 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.333 Critical Load Case: 275 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 63 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.290 Critical Load Case: 220 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 66
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 64 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.292 Critical Load Case: 221 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 65 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.326 Critical Load Case: 220 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 66 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.319 Critical Load Case: 221 Location: 1.15 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 67 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.295 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 68 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.303 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 69 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.427 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 70 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.326 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 71 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.100 Critical Load Case: 283 Location: 0.17 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 72 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 73 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 74 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 75 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 76 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 67
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 77 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.104 Critical Load Case: 220 Location: 0.26 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 78 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.101 Critical Load Case: 220 Location: 0.26 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 79 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.291 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 80 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.354 Critical Load Case: 275 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 81 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.217 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 82 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 83 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 84 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 85 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.132 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 86 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.134 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 87 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.660 Critical Load Case: 276 Location: 1.60 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 88 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.727 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 89 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 68
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.713 Critical Load Case: 291 Location: 1.46 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 90 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.659 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 91 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.316 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 92 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.548 Critical Load Case: 275 Location: 0.94 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 93 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.390 Critical Load Case: 224 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 94 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.233 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 95 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.587 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 96 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.489 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 97 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.249 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 98 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.301 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 99 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 236 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 100 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.247 Critical Load Case: 220 Location: 2.50 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 101 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.489 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 102 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 69
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |


| Status: PASS Ratio: 0.399 Critical Load Case: 227 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 103 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.333 Critical Load Case: 228 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 104 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.119 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 105 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.387 Critical Load Case: 310 Location: 1.82 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 106 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.180 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 107 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 108 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.427 Critical Load Case: 311 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 109 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.403 Critical Load Case: 302 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 110 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.232 Critical Load Case: 220 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 111 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.241 Critical Load Case: 221 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 112 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.323 Critical Load Case: 220 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 113 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.328 Critical Load Case: 221 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 114 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 220 Location: 1.15 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 70
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 115 |


| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.355 Critical Load Case: 221 Location: 1.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 116 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.337 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 117 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.331 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 118 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.617 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 119 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.884 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 120 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.367 Critical Load Case: 220 Location: 1.40 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 121 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.350 Critical Load Case: 276 Location: 2.85 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 122 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 123 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 225 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 124 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.255 Critical Load Case: 229 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 125 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.270 Critical Load Case: 229 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 126 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.667 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 127 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.612 Critical Load Case: 225 Location: 0.00 |
| Critical Condition: Slenderness |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 71
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 128 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.612 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 129 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.360 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 130 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.633 Critical Load Case: 276 Location: 1.13 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 131 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.584 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 132 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.337 Critical Load Case: 229 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 133 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.280 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 134 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.303 Critical Load Case: 229 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 135 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.280 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 136 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.679 Critical Load Case: 229 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 137 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.265 Critical Load Case: 221 Location: 3.30 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 138 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.457 Critical Load Case: 221 Location: 3.30 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 139 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 140 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.679 Critical Load Case: 230 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 72
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 141 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.459 Critical Load Case: 220 Location: 1.40 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 142 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.252 Critical Load Case: 275 Location: 2.85 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 143 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 144 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.321 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 145 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.963 Critical Load Case: 268 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 146 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 147 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.512 Critical Load Case: 225 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 148 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.255 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 149 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.503 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 150 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.612 Critical Load Case: 225 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 151 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.612 Critical Load Case: 225 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 152 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.612 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 153 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 73
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.360 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 154 |
| Member Section: ST UC305X305X96.9 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.258 Critical Load Case: 310 Location: 3.30 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 155 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.537 Critical Load Case: 220 Location: 3.30 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 156 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.203 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 157 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.612 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 158 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 159 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 160 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 161 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 228 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 162 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 163 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 164 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 165 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 251 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 166 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 74
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST ISMC150 (INDIAN SECTIONS) |


| Status: PASS Ratio: 0.914 Critical Load Case: 231 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 167 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 168 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 169 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 170 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 171 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 172 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 173 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 174 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 175 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 176 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 177 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 232 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 178 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 75
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 179 |


| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 180 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.777 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 181 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.914 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 182 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.289 Critical Load Case: 221 Location: 0.60 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 183 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.107 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 184 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.254 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 185 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.254 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 186 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.143 Critical Load Case: 238 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 187 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.158 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 188 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.314 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 189 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.143 Critical Load Case: 248 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 190 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.300 Critical Load Case: 220 Location: 0.60 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 191 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.462 Critical Load Case: 220 Location: 0.80 |
| Critical Condition: Sec. 9.3.2.2 (Y) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 76
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 192 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.202 Critical Load Case: 221 Location: 0.25 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 193 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.893 Critical Load Case: 276 Location: 0.71 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 194 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.694 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 195 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.215 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 196 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.696 Critical Load Case: 220 Location: 0.53 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 197 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.526 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 198 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.260 Critical Load Case: 220 Location: 0.53 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 199 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.385 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
|* Member Number: 200 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: FAIL Ratio: 1.075 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
|* Member Number: 201 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: FAIL Ratio: 1.172 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 202 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.705 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 203 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.335 Critical Load Case: 270 Location: 0.80 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 204 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.136 Critical Load Case: 221 Location: 0.22 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 77
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 205 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.993 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 206 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.348 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 207 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.358 Critical Load Case: 221 Location: 0.53 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 208 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.357 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 209 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.231 Critical Load Case: 220 Location: 0.53 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 210 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.195 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 211 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.380 Critical Load Case: 269 Location: 0.80 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 212 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.188 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 213 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.630 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 214 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.606 Critical Load Case: 268 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 215 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.289 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 216 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.326 Critical Load Case: 276 Location: 0.11 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 217 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 78
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.679 Critical Load Case: 220 Location: 2.92 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 218 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.549 Critical Load Case: 291 Location: 2.92 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 219 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.364 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 220 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.679 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 221 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.549 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 222 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.364 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 223 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.384 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 224 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.854 Critical Load Case: 228 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 225 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.419 Critical Load Case: 262 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 226 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 227 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 228 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 224 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 229 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.587 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 230 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 79
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST ISMC150 (INDIAN SECTIONS) |


| Status: PASS Ratio: 0.587 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 231 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.382 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 232 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.382 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 233 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.382 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 234 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.382 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 235 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.587 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 236 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.587 Critical Load Case: 223 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 237 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.677 Critical Load Case: 235 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 238 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.305 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 239 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.907 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 240 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.818 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 241 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.585 Critical Load Case: 268 Location: 3.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 242 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.520 Critical Load Case: 291 Location: 3.16 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 80
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 243 |


| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.586 Critical Load Case: 268 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 244 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.522 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 245 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.428 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 246 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.924 Critical Load Case: 224 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 247 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.441 Critical Load Case: 269 Location: 0.31 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 248 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.476 Critical Load Case: 268 Location: 2.09 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 249 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.746 Critical Load Case: 292 Location: 1.61 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 250 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.485 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 251 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.348 Critical Load Case: 228 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 252 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.476 Critical Load Case: 239 Location: 1.61 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 253 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.790 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 254 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.724 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 255 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.594 Critical Load Case: 276 Location: 3.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 81
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 256 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.474 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 257 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.429 Critical Load Case: 220 Location: 1.08 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 258 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.475 Critical Load Case: 269 Location: 2.09 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 259 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.301 Critical Load Case: 264 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 260 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.333 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 261 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.595 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 262 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.474 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 263 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.951 Critical Load Case: 259 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 264 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.924 Critical Load Case: 268 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 265 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.658 Critical Load Case: 276 Location: 1.61 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 266 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.485 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 267 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.348 Critical Load Case: 260 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 268 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.348 Critical Load Case: 220 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 82
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 269 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 228 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 270 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 271 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 228 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 272 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 273 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.780 Critical Load Case: 268 Location: 0.16 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 274 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 275 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 276 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.360 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 277 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.596 Critical Load Case: 242 Location: 3.01 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 278 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.598 Critical Load Case: 220 Location: 3.01 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 279 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 280 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 281 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 83
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.570 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 282 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 283 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.448 Critical Load Case: 230 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 284 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.448 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 285 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.533 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 286 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.533 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 287 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.582 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 288 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.582 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 289 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.255 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 290 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.471 Critical Load Case: 230 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 291 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.690 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 292 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.771 Critical Load Case: 277 Location: 2.62 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 293 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.690 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 294 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 84
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST ISMC150 (INDIAN SECTIONS) |


| Status: PASS Ratio: 0.771 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 295 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.796 Critical Load Case: 261 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 296 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.766 Critical Load Case: 266 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 297 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.596 Critical Load Case: 242 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 298 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.598 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 299 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.396 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 300 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.396 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 301 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.343 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 302 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.173 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 303 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.136 Critical Load Case: 236 Location: 0.30 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 304 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.448 Critical Load Case: 230 Location: 0.21 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 305 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.136 Critical Load Case: 221 Location: 0.19 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 306 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.448 Critical Load Case: 230 Location: 2.08 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 85
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 307 |


| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 308 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 230 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 309 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.210 Critical Load Case: 275 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 310 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.360 Critical Load Case: 222 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 311 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.399 Critical Load Case: 226 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 312 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 313 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 314 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 315 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 316 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.525 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 317 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.570 Critical Load Case: 277 Location: 1.75 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 318 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.898 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 319 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.898 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 86
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 320 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.448 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 321 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.448 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 322 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.582 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 323 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.582 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 324 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.533 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 325 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.533 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 326 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.907 Critical Load Case: 276 Location: 0.88 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 327 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.646 Critical Load Case: 220 Location: 3.01 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 328 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.600 Critical Load Case: 220 Location: 3.01 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 329 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.645 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 330 |
| Member Section: ST UC152X152X23 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.599 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 331 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.396 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 332 |
| Member Section: ST ISMC125 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.396 Critical Load Case: 220 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 87
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 333 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.185 Critical Load Case: 233 Location: 0.13 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 334 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.647 Critical Load Case: 220 Location: 1.39 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 335 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.793 Critical Load Case: 268 Location: 1.37 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 336 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.764 Critical Load Case: 268 Location: 1.37 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 337 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.907 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 338 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.893 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 339 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.215 Critical Load Case: 247 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 340 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.256 Critical Load Case: 268 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 341 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.713 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 342 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.961 Critical Load Case: 220 Location: 2.81 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 343 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.919 Critical Load Case: 220 Location: 2.81 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 344 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.287 Critical Load Case: 221 Location: 2.81 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 345 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 88
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.648 Critical Load Case: 221 Location: 1.30 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 346 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.721 Critical Load Case: 221 Location: 1.30 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 347 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.763 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 348 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.855 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 349 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.564 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 350 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.831 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 351 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.446 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 352 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.357 Critical Load Case: 221 Location: 1.30 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 353 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.449 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 354 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.357 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 355 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.775 Critical Load Case: 222 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 356 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.346 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 357 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.673 Critical Load Case: 222 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 358 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 89
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST ISMC150 (INDIAN SECTIONS) |


| Status: PASS Ratio: 0.508 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 359 |
| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.475 Critical Load Case: 220 Location: 1.39 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 360 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.330 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 361 |
| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.759 Critical Load Case: 220 Location: 1.39 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 362 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.280 Critical Load Case: 278 Location: 1.26 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 363 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.454 Critical Load Case: 220 Location: 1.39 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 364 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.328 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 365 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.458 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 366 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.281 Critical Load Case: 276 Location: 1.19 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 367 |
| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.773 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 368 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.264 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 369 |
| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.478 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 370 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.270 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 90
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 371 |


| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.436 Critical Load Case: 220 Location: 1.49 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 372 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.360 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 373 |
| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.422 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 374 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.476 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 375 |
| Member Section: ST ISMC200 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.566 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 376 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.219 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 377 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.449 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 378 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.261 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 379 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.657 Critical Load Case: 269 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 380 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.776 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 381 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.368 Critical Load Case: 275 Location: 0.21 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 382 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.549 Critical Load Case: 275 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 383 |
| Member Section: TAP ERED (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.424 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 91
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 384 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.270 Critical Load Case: 220 Location: 1.04 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 385 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.247 Critical Load Case: 277 Location: 0.72 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 386 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.503 Critical Load Case: 277 Location: 1.04 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 387 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.446 Critical Load Case: 222 Location: 0.88 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 388 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.227 Critical Load Case: 242 Location: 0.88 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 389 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.511 Critical Load Case: 294 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 390 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.300 Critical Load Case: 240 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 391 |
| Member Section: ST UB457X191X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.982 Critical Load Case: 227 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 392 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.224 Critical Load Case: 292 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 393 |
| Member Section: ST UB254X146X37 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.306 Critical Load Case: 292 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 394 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.237 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 395 |
| Member Section: ST UB305X165X40 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.156 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 396 |
| Member Section: ST UB457X191X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.118 Critical Load Case: 220 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 92
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 397 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.757 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 398 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.769 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 399 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.359 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 400 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.674 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 401 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.176 Critical Load Case: 268 Location: 1.56 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 402 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.170 Critical Load Case: 268 Location: 1.56 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 403 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.715 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 404 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.726 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Shear along Major Axis (Sec. 8.4) |
|----------------------------------------------------------------------------------|
| Member Number: 405 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.632 Critical Load Case: 293 Location: 0.80 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 406 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.616 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 407 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.233 Critical Load Case: 293 Location: 2.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 408 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.919 Critical Load Case: 220 Location: 2.25 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
|* Member Number: 409 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 93
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: FAIL Ratio: 1.182 Critical Load Case: 276 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
|* Member Number: 410 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: FAIL Ratio: 1.046 Critical Load Case: 268 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 411 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.402 Critical Load Case: 268 Location: 1.30 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 412 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.469 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 413 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.426 Critical Load Case: 293 Location: 0.59 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 414 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.541 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 415 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.300 Critical Load Case: 291 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 416 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.356 Critical Load Case: 294 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 417 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.132 Critical Load Case: 240 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 418 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.389 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 419 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.268 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 420 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.282 Critical Load Case: 292 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 421 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.137 Critical Load Case: 292 Location: 0.69 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 422 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 94
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |


| Status: PASS Ratio: 0.106 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 423 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.100 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 424 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.288 Critical Load Case: 292 Location: 1.15 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 425 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.099 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 426 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.255 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 427 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.183 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 428 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.447 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 429 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.420 Critical Load Case: 277 Location: 0.88 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
|* Member Number: 430 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: FAIL Ratio: 1.001 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 431 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.714 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 432 |
| Member Section: ST UC254X254X73.1 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.148 Critical Load Case: 292 Location: 2.25 |
| Critical Condition: Major Axis Bending (Sec. 8) |
|----------------------------------------------------------------------------------|
| Member Number: 433 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.295 Critical Load Case: 277 Location: 1.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 434 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.294 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 95
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Member Number: 435 |


| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.303 Critical Load Case: 277 Location: 1.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 436 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.880 Critical Load Case: 277 Location: 1.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 437 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.333 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 438 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.172 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 439 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.654 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 440 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.579 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 441 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.504 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 442 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.429 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 443 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.429 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 444 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.442 Critical Load Case: 220 Location: 1.04 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 445 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.509 Critical Load Case: 277 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 446 |
| Member Section: ST UB457X191X67 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.217 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 447 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.380 Critical Load Case: 294 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 96
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

|----------------------------------------------------------------------------------|
| Member Number: 448 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.197 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 449 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.198 Critical Load Case: 221 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 450 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.197 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 451 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.586 Critical Load Case: 277 Location: 1.08 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 452 |
| Member Section: ST UB203X133X25 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.197 Critical Load Case: 231 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 453 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.182 Critical Load Case: 269 Location: 0.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 454 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.467 Critical Load Case: 222 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 455 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.136 Critical Load Case: 236 Location: 0.09 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 456 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.149 Critical Load Case: 268 Location: 1.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 457 |
| Member Section: TAP ERED (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.687 Critical Load Case: 269 Location: 1.00 |
| Critical Condition: Sec. 9.3.1.1 |
|----------------------------------------------------------------------------------|
| Member Number: 458 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.244 Critical Load Case: 240 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 459 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.300 Critical Load Case: 240 Location: 0.35 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 460 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.542 Critical Load Case: 238 Location: 0.00 |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 97
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Critical Condition: Slenderness |


|----------------------------------------------------------------------------------|
| Member Number: 461 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.618 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 462 |
| Member Section: ST UB533X210X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.222 Critical Load Case: 303 Location: 0.09 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 463 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.693 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 464 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.628 Critical Load Case: 220 Location: 1.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 465 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.530 Critical Load Case: 232 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 466 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.530 Critical Load Case: 266 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 467 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.530 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 468 |
| Member Section: ST ISMC150 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.530 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 469 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.636 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 470 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.872 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 471 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.872 Critical Load Case: 220 Location: 1.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 472 |
| Member Section: ST UB203X133X30 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.839 Critical Load Case: 220 Location: 1.00 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 473 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 98
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

| Status: PASS Ratio: 0.576 Critical Load Case: 269 Location: 3.31 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 474 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.560 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 475 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.268 Critical Load Case: 221 Location: 1.50 |
| Critical Condition: Sec. 9.3.2.2 (Y) |
|----------------------------------------------------------------------------------|
| Member Number: 476 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.254 Critical Load Case: 220 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|
| Member Number: 477 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.918 Critical Load Case: 220 Location: 2.08 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 478 |
| Member Section: ST ISMC250 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.998 Critical Load Case: 220 Location: 2.08 |
| Critical Condition: Sec. 9.3.1.3 |
|----------------------------------------------------------------------------------|
| Member Number: 479 |
| Member Section: ST UB457X191X82 (JINDAL STEEL TABLE SECTIONS) |
| Status: PASS Ratio: 0.982 Critical Load Case: 227 Location: 0.00 |
| Critical Condition: Slenderness |
|----------------------------------------------------------------------------------|

4.4 MEMBER STRESS RATIOS

Allo
Normal
DESIGN Actual wabl Ax Iy Ix
BEAM ised Clause L/C Iz cm^4
PROPERTY Ratio e cm^2 cm^4 cm^4
ratio
ratio
1 UC305X305X96.9 0.307 1 0.307 Slenderness 220 123.4 22249 7307 91.8
2 UC305X305X96.9 0.218 1 0.218 Sec. 9.3.2.2 276 123.4 22249 7307 91.8
3 UC305X305X96.9 0.538 1 0.538 Sec. 9.3.2.2 276 123.4 22249 7307 91.8
4 UC305X305X96.9 0.496 1 0.496 Sec. 9.3.2.2 276 123.4 22249 7307 91.8
5 UC305X305X96.9 0.4 1 0.4 Sec. 9.3.2.2 276 123.4 22249 7307 91.8
6 UC305X305X96.9 0.331 1 0.331 Sec. 9.3.2.2 291 123.4 22249 7307 91.8
7 UC305X305X96.9 0.281 1 0.281 Slenderness 220 123.4 22249 7307 91.8
8 UC305X305X96.9 0.281 1 0.281 Slenderness 220 123.4 22249 7307 91.8
9 Taper 0.883 1 0.883 Sec. 9.3.1.1 276 204.0 93800 11256 338.4
10 Taper 0.29 1 0.29 Shear along 276 204.0 93800 11256 338.4
11 Taper 0.973 1 0.973 Sec. 9.3.2.2 268 204.0 93800 11256 338.4
12 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
13 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
14 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
15 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
16 UC305X305X96.9 0.107 1 0.107 Shear along 276 123.4 22249 7307 91.8
17 UC305X305X96.9 0.058 1 0.058 Slenderness 220 123.4 22249 7307 91.8
18 UB305X165X40 0.264 1 0.264 Sec. 9.3.2.2 276 51.3 8503 764 14.7
19 UB305X165X40 0.239 1 0.239 Sec. 9.3.2.2 276 51.3 8503 764 14.7
20 UB254X146X37 0.622 1 0.622 Slenderness 220 47.2 5537 571 15.4

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 99
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

21 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4


22 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
23 UB254X146X37 0.387 1 0.387 Slenderness 220 47.2 5537 571 15.4
24 UB254X146X37 0.622 1 0.622 Slenderness 233 47.2 5537 571 15.4
25 UB254X146X37 0.399 1 0.399 Slenderness 221 47.2 5537 571 15.4
26 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
27 UB254X146X37 0.399 1 0.399 Slenderness 223 47.2 5537 571 15.4
28 UB254X146X37 0.399 1 0.399 Slenderness 223 47.2 5537 571 15.4
29 UB254X146X37 0.399 1 0.399 Slenderness 227 47.2 5537 571 15.4
30 UB254X146X37 0.319 1 0.319 Slenderness 220 47.2 5537 571 15.4
31 UB254X146X37 0.319 1 0.319 Slenderness 224 47.2 5537 571 15.4
32 UB254X146X37 0.319 1 0.319 Slenderness 235 47.2 5537 571 15.4
33 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
34 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
35 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
36 UB305X165X40 0.118 1 0.118 Sec. 9.3.2.2 220 51.3 8503 764 14.7
37 UB305X165X40 0.113 1 0.113 Sec. 9.3.2.2 276 51.3 8503 764 14.7
38 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
39 UB305X165X40 0.199 1 0.199 Sec. 9.3.2.2 276 51.3 8503 764 14.7
40 UB305X165X40 0.216 1 0.216 Sec. 9.3.2.2 276 51.3 8503 764 14.7
41 UB305X165X40 0.188 1 0.188 Sec. 9.3.2.2 276 51.3 8503 764 14.7
42 UB254X146X37 0.232 1 0.232 Slenderness 220 47.2 5537 571 15.4
43 UB305X165X40 0.242 1 0.242 Sec. 9.3.2.2 276 51.3 8503 764 14.7
44 UC305X305X96.9 0.228 1 0.228 Sec. 9.3.2.2 220 123.4 22249 7307 91.8
45 UB203X133X25 0.365 1 0.365 Sec. 9.3.1.1 220 32.0 2340 308 6.1
46 UB203X133X25 0.076 1 0.076 Major Axis B 220 32.0 2340 308 6.1
47 UC305X305X96.9 0.352 1 0.352 Sec. 9.3.2.2 291 123.4 22249 7307 91.8
48 UC305X305X96.9 0.344 1 0.344 Sec. 9.3.2.2 291 123.4 22249 7307 91.8
49 UC305X305X96.9 0.468 1 0.468 Sec. 9.3.2.2 292 123.4 22249 7307 91.8
50 UC305X305X96.9 0.464 1 0.464 Sec. 9.3.2.2 291 123.4 22249 7307 91.8
51 UB305X165X40 0.596 1 0.596 Sec. 9.3.2.2 268 51.3 8503 764 14.7
52 Taper 0.541 1 0.541 Sec. 9.3.2.2 267 152.2 66492 7207 108.9
53 UB305X165X40 0.783 1 0.783 Major Axis B 268 51.3 8503 764 14.7
54 Taper 0.378 1 0.378 Sec. 9.3.2.2 267 152.2 66492 7207 108.9
55 UB305X165X40 0.777 1 0.777 Sec. 9.3.2.2 291 51.3 8503 764 14.7
56 Taper 0.777 1 0.777 Sec. 9.3.2.2 269 152.2 66492 7207 108.9
57 UB203X133X25 0.488 1 0.488 Sec. 9.3.2.2 276 32.0 2340 308 6.1
58 UB203X133X25 0.838 1 0.838 Sec. 9.3.2.2 291 32.0 2340 308 6.1
59 UB305X165X40 0.672 1 0.672 Sec. 9.3.2.2 303 51.3 8503 764 14.7
60 UB305X165X40 0.72 1 0.72 Sec. 9.3.2.2 221 51.3 8503 764 14.7
61 UB305X165X40 0.322 1 0.322 Sec. 9.3.2.2 292 51.3 8503 764 14.7
62 UB305X165X40 0.333 1 0.333 Sec. 9.3.2.2 275 51.3 8503 764 14.7
63 UB305X165X40 0.29 1 0.29 Sec. 9.3.2.2 220 51.3 8503 764 14.7
64 UB305X165X40 0.292 1 0.292 Sec. 9.3.2.2 221 51.3 8503 764 14.7
65 UB305X165X40 0.326 1 0.326 Sec. 9.3.2.2 220 51.3 8503 764 14.7
66 UB305X165X40 0.319 1 0.319 Sec. 9.3.2.2 221 51.3 8503 764 14.7
67 UB305X165X40 0.295 1 0.295 Sec. 9.3.2.2 220 51.3 8503 764 14.7
68 UB305X165X40 0.303 1 0.303 Sec. 9.3.2.2 220 51.3 8503 764 14.7
69 UB305X165X40 0.427 1 0.427 Sec. 9.3.2.2 276 51.3 8503 764 14.7
70 UB305X165X40 0.326 1 0.326 Sec. 9.3.2.2 291 51.3 8503 764 14.7
71 UB305X165X40 0.1 1 0.1 Sec. 9.3.2.2 283 51.3 8503 764 14.7
72 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
73 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
74 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
75 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
76 UB305X165X40 0.18 1 0.18 Slenderness 220 51.3 8503 764 14.7
77 UB305X165X40 0.104 1 0.104 Sec. 9.3.2.2 220 51.3 8503 764 14.7
78 UB305X165X40 0.101 1 0.101 Sec. 9.3.2.2 220 51.3 8503 764 14.7

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 100
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

79 UC305X305X96.9 0.291 1 0.291 Sec. 9.3.2.2 291 123.4 22249 7307 91.8
80 UC305X305X96.9 0.354 1 0.354 Sec. 9.3.2.2 275 123.4 22249 7307 91.8
81 UC305X305X96.9 0.217 1 0.217 Sec. 9.3.2.2 220 123.4 22249 7307 91.8
82 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
83 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
84 UC305X305X96.9 0.181 1 0.181 Slenderness 220 123.4 22249 7307 91.8
85 UC305X305X96.9 0.132 1 0.132 Shear along 276 123.4 22249 7307 91.8
86 UC305X305X96.9 0.134 1 0.134 Shear along 220 123.4 22249 7307 91.8
87 UB305X165X40 0.66 1 0.66 Sec. 9.3.2.2 276 51.3 8503 764 14.7
88 UB305X165X40 0.727 1 0.727 Major Axis B 276 51.3 8503 764 14.7
89 UB305X165X40 0.713 1 0.713 Sec. 9.3.2.2 291 51.3 8503 764 14.7
90 Taper 0.659 1 0.659 Sec. 9.3.1.1 277 152.2 66492 7207 108.9
91 UB305X165X40 0.316 1 0.316 Major Axis B 220 51.3 8503 764 14.7
92 Taper 0.548 1 0.548 Sec. 9.3.2.2 275 152.2 66492 7207 108.9
93 UB254X146X37 0.39 1 0.39 Slenderness 224 47.2 5537 571 15.4
94 Taper 0.233 1 0.233 Sec. 9.3.1.1 277 152.2 66492 7207 108.9
95 UB254X146X37 0.587 1 0.587 Sec. 9.3.2.2 291 47.2 5537 571 15.4
96 UB305X165X40 0.489 1 0.489 Slenderness 223 51.3 8503 764 14.7
97 UB254X146X37 0.249 1 0.249 Sec. 9.3.1.1 277 47.2 5537 571 15.4
98 UB305X165X40 0.301 1 0.301 Slenderness 223 51.3 8503 764 14.7
99 UB254X146X37 0.399 1 0.399 Slenderness 236 47.2 5537 571 15.4
100 UB254X146X37 0.247 1 0.247 Major Axis B 220 47.2 5537 571 15.4
101 UB254X146X37 0.489 1 0.489 Sec. 9.3.2.2 220 47.2 5537 571 15.4
102 UB254X146X37 0.399 1 0.399 Slenderness 227 47.2 5537 571 15.4
103 UB254X146X37 0.333 1 0.333 Slenderness 228 47.2 5537 571 15.4
104 UB305X165X40 0.119 1 0.119 Slenderness 223 51.3 8503 764 14.7
105 UB254X146X37 0.387 1 0.387 Slenderness 310 47.2 5537 571 15.4
106 UB254X146X37 0.18 1 0.18 Slenderness 220 47.2 5537 571 15.4
107 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
108 UB305X165X40 0.427 1 0.427 Sec. 9.3.2.2 311 51.3 8503 764 14.7
109 UB305X165X40 0.403 1 0.403 Sec. 9.3.2.2 302 51.3 8503 764 14.7
110 UB305X165X40 0.232 1 0.232 Sec. 9.3.2.2 220 51.3 8503 764 14.7
111 UB305X165X40 0.241 1 0.241 Sec. 9.3.2.2 221 51.3 8503 764 14.7
112 UB305X165X40 0.323 1 0.323 Sec. 9.3.2.2 220 51.3 8503 764 14.7
113 UB305X165X40 0.328 1 0.328 Sec. 9.3.2.2 221 51.3 8503 764 14.7
114 UB305X165X40 0.352 1 0.352 Sec. 9.3.2.2 220 51.3 8503 764 14.7
115 UB305X165X40 0.355 1 0.355 Sec. 9.3.2.2 221 51.3 8503 764 14.7
116 UB305X165X40 0.337 1 0.337 Sec. 9.3.2.2 221 51.3 8503 764 14.7
117 UB305X165X40 0.331 1 0.331 Sec. 9.3.2.2 220 51.3 8503 764 14.7
118 UC305X305X96.9 0.617 1 0.617 Sec. 9.3.2.2 277 123.4 22249 7307 91.8
119 Taper 0.884 1 0.884 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
120 UC305X305X96.9 0.367 1 0.367 Sec. 9.3.2.2 220 123.4 22249 7307 91.8
121 UC305X305X96.9 0.35 1 0.35 Sec. 9.3.2.2 276 123.4 22249 7307 91.8
122 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
123 UB254X146X37 0.399 1 0.399 Slenderness 225 47.2 5537 571 15.4
124 UB457X191X67 0.255 1 0.255 Slenderness 229 85.5 29380 1452 37.5
125 UB457X191X67 0.27 1 0.27 Slenderness 229 85.5 29380 1452 37.5
126 Taper 0.667 1 0.667 Sec. 9.3.2.2 277 136.2 57119 4173 95.2
127 UB305X165X40 0.612 1 0.612 Slenderness 225 51.3 8503 764 14.7
128 UB305X165X40 0.612 1 0.612 Slenderness 221 51.3 8503 764 14.7
129 UB305X165X40 0.36 1 0.36 Slenderness 221 51.3 8503 764 14.7
130 Taper 0.633 1 0.633 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
131 Taper 0.584 1 0.584 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
132 UB457X191X67 0.337 1 0.337 Slenderness 229 85.5 29380 1452 37.5
133 UB254X146X37 0.28 1 0.28 Slenderness 220 47.2 5537 571 15.4
134 UB457X191X67 0.303 1 0.303 Slenderness 229 85.5 29380 1452 37.5
135 UB254X146X37 0.28 1 0.28 Slenderness 220 47.2 5537 571 15.4
136 UB254X146X37 0.679 1 0.679 Slenderness 229 47.2 5537 571 15.4

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 101
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

137 UC305X305X96.9 0.265 1 0.265 Sec. 9.3.2.2 221 123.4 22249 7307 91.8
138 UB254X146X37 0.457 1 0.457 Major Axis B 221 47.2 5537 571 15.4
139 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
140 UB254X146X37 0.679 1 0.679 Slenderness 230 47.2 5537 571 15.4
141 UC305X305X96.9 0.459 1 0.459 Sec. 9.3.2.2 220 123.4 22249 7307 91.8
142 UC305X305X96.9 0.252 1 0.252 Sec. 9.3.2.2 275 123.4 22249 7307 91.8
143 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
144 UC305X305X96.9 0.321 1 0.321 Sec. 9.3.2.2 220 123.4 22249 7307 91.8
145 Taper 0.963 1 0.963 Sec. 9.3.1.1 268 216.0 140700 11258 344.2
146 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
147 UB457X191X67 0.512 1 0.512 Slenderness 225 85.5 29380 1452 37.5
148 UB457X191X67 0.255 1 0.255 Slenderness 221 85.5 29380 1452 37.5
149 Taper 0.503 1 0.503 Sec. 9.3.1.1 269 136.2 57119 4173 95.2
150 UB305X165X40 0.612 1 0.612 Slenderness 225 51.3 8503 764 14.7
151 UB305X165X40 0.612 1 0.612 Slenderness 225 51.3 8503 764 14.7
152 UB305X165X40 0.612 1 0.612 Slenderness 220 51.3 8503 764 14.7
153 UB305X165X40 0.36 1 0.36 Slenderness 220 51.3 8503 764 14.7
154 UC305X305X96.9 0.258 1 0.258 Sec. 9.3.2.2 310 123.4 22249 7307 91.8
155 UB254X146X37 0.537 1 0.537 Sec. 9.3.2.2 220 47.2 5537 571 15.4
156 UB305X165X40 0.203 1 0.203 Slenderness 226 51.3 8503 764 14.7
157 UB305X165X40 0.612 1 0.612 Slenderness 226 51.3 8503 764 14.7
158 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
159 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
160 ISMC150 0.914 1 0.914 Slenderness 220 21.3 788 102 5.4
161 ISMC150 0.777 1 0.777 Slenderness 228 21.3 788 102 5.4
162 ISMC150 0.777 1 0.777 Slenderness 221 21.3 788 102 5.4
163 ISMC150 0.914 1 0.914 Slenderness 220 21.3 788 102 5.4
164 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
165 ISMC150 0.777 1 0.777 Slenderness 251 21.3 788 102 5.4
166 ISMC150 0.914 1 0.914 Slenderness 231 21.3 788 102 5.4
167 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
168 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
169 ISMC150 0.914 1 0.914 Slenderness 220 21.3 788 102 5.4
170 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
171 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
172 ISMC150 0.914 1 0.914 Slenderness 220 21.3 788 102 5.4
173 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
174 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
175 ISMC150 0.914 1 0.914 Slenderness 220 21.3 788 102 5.4
176 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
177 ISMC150 0.777 1 0.777 Slenderness 232 21.3 788 102 5.4
178 ISMC150 0.914 1 0.914 Slenderness 221 21.3 788 102 5.4
179 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
180 ISMC150 0.777 1 0.777 Slenderness 220 21.3 788 102 5.4
181 ISMC150 0.914 1 0.914 Slenderness 220 21.3 788 102 5.4
182 UB203X133X25 0.289 1 0.289 Major Axis B 221 32.0 2340 308 6.1
183 UB203X133X25 0.107 1 0.107 Slenderness 220 32.0 2340 308 6.1
184 ISMC250 0.254 1 0.254 Slenderness 220 39.0 3838 218 18.8
185 ISMC250 0.254 1 0.254 Slenderness 220 39.0 3838 218 18.8
186 UB203X133X25 0.143 1 0.143 Slenderness 238 32.0 2340 308 6.1
187 UB203X133X25 0.158 1 0.158 Shear along 221 32.0 2340 308 6.1
188 UB203X133X25 0.314 1 0.314 Sec. 9.3.2.2 221 32.0 2340 308 6.1
189 UB203X133X25 0.143 1 0.143 Slenderness 248 32.0 2340 308 6.1
190 UB203X133X25 0.3 1 0.3 Sec. 9.3.1.1 220 32.0 2340 308 6.1
191 UB203X133X25 0.462 1 0.462 Sec. 9.3.2.2 220 32.0 2340 308 6.1
192 UB203X133X25 0.202 1 0.202 Shear along 221 32.0 2340 308 6.1
193 Taper 0.893 1 0.893 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
194 UB203X133X25 0.694 1 0.694 Sec. 9.3.1.1 220 32.0 2340 308 6.1

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 102
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

195 UB203X133X25 0.215 1 0.215 Sec. 9.3.1.1 220 32.0 2340 308 6.1
196 ISMC250 0.696 1 0.696 Sec. 9.3.1.3 220 39.0 3838 218 18.8
197 ISMC250 0.526 1 0.526 Sec. 9.3.1.3 221 39.0 3838 218 18.8
198 ISMC250 0.26 1 0.26 Sec. 9.3.1.3 220 39.0 3838 218 18.8
199 ISMC250 0.385 1 0.385 Sec. 9.3.1.3 220 39.0 3838 218 18.8
200 ISMC250 1.075 1 1.075 Sec. 9.3.1.3 220 39.0 3838 218 18.8
201 ISMC250 1.172 1 1.172 Sec. 9.3.1.3 220 39.0 3838 218 18.8
202 ISMC250 0.705 1 0.705 Sec. 9.3.1.3 220 39.0 3838 218 18.8
203 ISMC250 0.335 1 0.335 Sec. 9.3.1.3 270 39.0 3838 218 18.8
204 Taper 0.136 1 0.136 Slenderness 221 136.2 57119 4173 95.2
205 UB203X133X30 0.993 1 0.993 Sec. 9.3.1.1 220 38.2 2896 385 10.4
206 UB203X133X30 0.348 1 0.348 Sec. 9.3.1.1 220 38.2 2896 385 10.4
207 ISMC250 0.358 1 0.358 Sec. 9.3.1.3 221 39.0 3838 218 18.8
208 ISMC250 0.357 1 0.357 Sec. 9.3.1.3 220 39.0 3838 218 18.8
209 ISMC250 0.231 1 0.231 Sec. 9.3.1.3 220 39.0 3838 218 18.8
210 ISMC250 0.195 1 0.195 Sec. 9.3.1.3 220 39.0 3838 218 18.8
211 ISMC250 0.38 1 0.38 Sec. 9.3.1.3 269 39.0 3838 218 18.8
212 ISMC250 0.188 1 0.188 Slenderness 220 39.0 3838 218 18.8
213 ISMC250 0.63 1 0.63 Sec. 9.3.1.3 269 39.0 3838 218 18.8
214 ISMC250 0.606 1 0.606 Sec. 9.3.2.2 268 39.0 3838 218 18.8
215 Taper 0.289 1 0.289 Sec. 9.3.2.2 276 204.0 93800 11256 338.4
216 Taper 0.326 1 0.326 Sec. 9.3.2.2 276 204.0 93800 11256 338.4
217 UC152X152X23 0.679 1 0.679 Sec. 9.3.2.2 220 29.2 1250 400 4.9
218 UC152X152X23 0.549 1 0.549 Sec. 9.3.2.2 291 29.2 1250 400 4.9
219 ISMC150 0.364 1 0.364 Slenderness 220 21.3 788 102 5.4
220 UC152X152X23 0.679 1 0.679 Sec. 9.3.2.2 220 29.2 1250 400 4.9
221 UC152X152X23 0.549 1 0.549 Sec. 9.3.2.2 291 29.2 1250 400 4.9
222 ISMC150 0.364 1 0.364 Slenderness 220 21.3 788 102 5.4
223 ISMC125 0.384 1 0.384 Slenderness 220 16.6 422 60 3.5
224 ISMC125 0.854 1 0.854 Slenderness 228 16.6 422 60 3.5
225 ISMC125 0.419 1 0.419 Slenderness 262 16.6 422 60 3.5
226 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
227 UB254X146X37 0.399 1 0.399 Slenderness 220 47.2 5537 571 15.4
228 UB254X146X37 0.399 1 0.399 Slenderness 224 47.2 5537 571 15.4
229 ISMC150 0.587 1 0.587 Slenderness 220 21.3 788 102 5.4
230 ISMC150 0.587 1 0.587 Slenderness 223 21.3 788 102 5.4
231 UC152X152X23 0.382 1 0.382 Slenderness 220 29.2 1250 400 4.9
232 UC152X152X23 0.382 1 0.382 Slenderness 223 29.2 1250 400 4.9
233 UC152X152X23 0.382 1 0.382 Slenderness 220 29.2 1250 400 4.9
234 UC152X152X23 0.382 1 0.382 Slenderness 223 29.2 1250 400 4.9
235 ISMC150 0.587 1 0.587 Slenderness 220 21.3 788 102 5.4
236 ISMC150 0.587 1 0.587 Slenderness 223 21.3 788 102 5.4
237 ISMC125 0.677 1 0.677 Slenderness 235 16.6 422 60 3.5
238 ISMC125 0.305 1 0.305 Slenderness 220 16.6 422 60 3.5
239 UB305X165X40 0.907 1 0.907 Sec. 9.3.2.2 276 51.3 8503 764 14.7
240 UB305X165X40 0.818 1 0.818 Major Axis B 291 51.3 8503 764 14.7
241 UC152X152X23 0.585 1 0.585 Sec. 9.3.2.2 268 29.2 1250 400 4.9
242 UC152X152X23 0.52 1 0.52 Sec. 9.3.2.2 291 29.2 1250 400 4.9
243 UC152X152X23 0.586 1 0.586 Sec. 9.3.2.2 268 29.2 1250 400 4.9
244 UC152X152X23 0.522 1 0.522 Sec. 9.3.2.2 291 29.2 1250 400 4.9
245 ISMC125 0.428 1 0.428 Slenderness 220 16.6 422 60 3.5
246 ISMC125 0.924 1 0.924 Slenderness 224 16.6 422 60 3.5
247 Taper 0.441 1 0.441 Sec. 9.3.2.2 269 152.2 66492 7207 108.9
248 Taper 0.476 1 0.476 Sec. 9.3.2.2 268 152.2 66492 7207 108.9
249 UC152X152X23 0.746 1 0.746 Sec. 9.3.2.2 292 29.2 1250 400 4.9
250 UC152X152X23 0.485 1 0.485 Slenderness 220 29.2 1250 400 4.9
251 UC152X152X23 0.348 1 0.348 Slenderness 228 29.2 1250 400 4.9
252 UC152X152X23 0.476 1 0.476 Sec. 9.3.2.2 239 29.2 1250 400 4.9

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 103
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

253 UB305X165X40 0.79 1 0.79 Major Axis B 276 51.3 8503 764 14.7
254 UB305X165X40 0.724 1 0.724 Sec. 9.3.2.2 291 51.3 8503 764 14.7
255 UC152X152X23 0.594 1 0.594 Sec. 9.3.2.2 276 29.2 1250 400 4.9
256 UC152X152X23 0.474 1 0.474 Slenderness 220 29.2 1250 400 4.9
257 Taper 0.429 1 0.429 Sec. 9.3.2.2 220 152.2 66492 7207 108.9
258 Taper 0.475 1 0.475 Sec. 9.3.1.1 269 152.2 66492 7207 108.9
259 UB305X165X40 0.301 1 0.301 Slenderness 264 51.3 8503 764 14.7
260 UB254X146X37 0.333 1 0.333 Slenderness 220 47.2 5537 571 15.4
261 UC152X152X23 0.595 1 0.595 Sec. 9.3.2.2 276 29.2 1250 400 4.9
262 UC152X152X23 0.474 1 0.474 Slenderness 220 29.2 1250 400 4.9
263 ISMC125 0.951 1 0.951 Slenderness 259 16.6 422 60 3.5
264 ISMC125 0.924 1 0.924 Slenderness 268 16.6 422 60 3.5
265 UC152X152X23 0.658 1 0.658 Sec. 9.3.2.2 276 29.2 1250 400 4.9
266 UC152X152X23 0.485 1 0.485 Slenderness 220 29.2 1250 400 4.9
267 UC152X152X23 0.348 1 0.348 Slenderness 260 29.2 1250 400 4.9
268 UC152X152X23 0.348 1 0.348 Slenderness 220 29.2 1250 400 4.9
269 UC152X152X23 0.352 1 0.352 Slenderness 228 29.2 1250 400 4.9
270 UC152X152X23 0.352 1 0.352 Slenderness 220 29.2 1250 400 4.9
271 UC152X152X23 0.352 1 0.352 Slenderness 228 29.2 1250 400 4.9
272 UC152X152X23 0.352 1 0.352 Slenderness 220 29.2 1250 400 4.9
273 Taper 0.78 1 0.78 Sec. 9.3.1.1 268 216.0 140700 11258 344.2
274 UB254X146X37 0.399 1 0.399 Slenderness 221 47.2 5537 571 15.4
275 UB254X146X37 0.399 1 0.399 Slenderness 226 47.2 5537 571 15.4
276 UB305X165X40 0.36 1 0.36 Slenderness 226 51.3 8503 764 14.7
277 UC152X152X23 0.596 1 0.596 Sec. 9.3.2.2 242 29.2 1250 400 4.9
278 UC152X152X23 0.598 1 0.598 Sec. 9.3.2.2 220 29.2 1250 400 4.9
279 UC152X152X23 0.57 1 0.57 Slenderness 226 29.2 1250 400 4.9
280 UC152X152X23 0.57 1 0.57 Slenderness 220 29.2 1250 400 4.9
281 UC152X152X23 0.57 1 0.57 Slenderness 221 29.2 1250 400 4.9
282 UC152X152X23 0.57 1 0.57 Slenderness 220 29.2 1250 400 4.9
283 UC152X152X23 0.448 1 0.448 Slenderness 230 29.2 1250 400 4.9
284 UC152X152X23 0.448 1 0.448 Slenderness 220 29.2 1250 400 4.9
285 UC152X152X23 0.533 1 0.533 Slenderness 220 29.2 1250 400 4.9
286 UC152X152X23 0.533 1 0.533 Slenderness 220 29.2 1250 400 4.9
287 UC152X152X23 0.582 1 0.582 Slenderness 220 29.2 1250 400 4.9
288 UC152X152X23 0.582 1 0.582 Slenderness 220 29.2 1250 400 4.9
289 UB457X191X67 0.255 1 0.255 Slenderness 221 85.5 29380 1452 37.5
290 UB457X191X67 0.471 1 0.471 Slenderness 230 85.5 29380 1452 37.5
291 ISMC150 0.69 1 0.69 Slenderness 221 21.3 788 102 5.4
292 ISMC150 0.771 1 0.771 Sec. 9.3.2.2 277 21.3 788 102 5.4
293 ISMC150 0.69 1 0.69 Slenderness 221 21.3 788 102 5.4
294 ISMC150 0.771 1 0.771 Sec. 9.3.2.2 277 21.3 788 102 5.4
295 ISMC125 0.796 1 0.796 Slenderness 261 16.6 422 60 3.5
296 ISMC125 0.766 1 0.766 Slenderness 266 16.6 422 60 3.5
297 UC152X152X23 0.596 1 0.596 Sec. 9.3.2.2 242 29.2 1250 400 4.9
298 UC152X152X23 0.598 1 0.598 Sec. 9.3.2.2 220 29.2 1250 400 4.9
299 ISMC125 0.396 1 0.396 Slenderness 220 16.6 422 60 3.5
300 ISMC125 0.396 1 0.396 Slenderness 220 16.6 422 60 3.5
301 UB305X165X40 0.343 1 0.343 Slenderness 226 51.3 8503 764 14.7
302 UB305X165X40 0.173 1 0.173 Slenderness 226 51.3 8503 764 14.7
303 Taper 0.136 1 0.136 Slenderness 236 136.2 57119 4173 95.2
304 UB203X133X25 0.448 1 0.448 Slenderness 230 32.0 2340 308 6.1
305 Taper 0.136 1 0.136 Slenderness 221 136.2 57119 4173 95.2
306 UB203X133X25 0.448 1 0.448 Slenderness 230 32.0 2340 308 6.1
307 UB254X146X37 0.399 1 0.399 Slenderness 221 47.2 5537 571 15.4
308 UB254X146X37 0.399 1 0.399 Slenderness 230 47.2 5537 571 15.4
309 Taper 0.21 1 0.21 Sec. 9.3.1.1 275 136.2 57119 4173 95.2
310 UB305X165X40 0.36 1 0.36 Slenderness 222 51.3 8503 764 14.7

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 104
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

311 UB254X146X37 0.399 1 0.399 Slenderness 226 47.2 5537 571 15.4
312 UC152X152X23 0.57 1 0.57 Slenderness 221 29.2 1250 400 4.9
313 UC152X152X23 0.57 1 0.57 Slenderness 220 29.2 1250 400 4.9
314 UC152X152X23 0.57 1 0.57 Slenderness 221 29.2 1250 400 4.9
315 UC152X152X23 0.57 1 0.57 Slenderness 220 29.2 1250 400 4.9
316 UC152X152X23 0.525 1 0.525 Slenderness 221 29.2 1250 400 4.9
317 UC152X152X23 0.57 1 0.57 Sec. 9.3.2.2 277 29.2 1250 400 4.9
318 ISMC150 0.898 1 0.898 Slenderness 220 21.3 788 102 5.4
319 ISMC150 0.898 1 0.898 Slenderness 220 21.3 788 102 5.4
320 UC152X152X23 0.448 1 0.448 Slenderness 220 29.2 1250 400 4.9
321 UC152X152X23 0.448 1 0.448 Slenderness 221 29.2 1250 400 4.9
322 UC152X152X23 0.582 1 0.582 Slenderness 220 29.2 1250 400 4.9
323 UC152X152X23 0.582 1 0.582 Slenderness 220 29.2 1250 400 4.9
324 UC152X152X23 0.533 1 0.533 Slenderness 220 29.2 1250 400 4.9
325 UC152X152X23 0.533 1 0.533 Slenderness 220 29.2 1250 400 4.9
326 Taper 0.907 1 0.907 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
327 UC152X152X23 0.646 1 0.646 Sec. 9.3.2.2 220 29.2 1250 400 4.9
328 UC152X152X23 0.6 1 0.6 Sec. 9.3.2.2 220 29.2 1250 400 4.9
329 UC152X152X23 0.645 1 0.645 Sec. 9.3.2.2 220 29.2 1250 400 4.9
330 UC152X152X23 0.599 1 0.599 Sec. 9.3.2.2 220 29.2 1250 400 4.9
331 ISMC125 0.396 1 0.396 Slenderness 220 16.6 422 60 3.5
332 ISMC125 0.396 1 0.396 Slenderness 220 16.6 422 60 3.5
333 Taper 0.185 1 0.185 Slenderness 233 216.0 140700 11258 344.2
334 Taper 0.647 1 0.647 Sec. 9.3.2.2 220 216.0 140700 11258 344.2
335 Taper 0.793 1 0.793 Sec. 9.3.1.1 268 216.0 140700 11258 344.2
336 Taper 0.764 1 0.764 Sec. 9.3.1.1 268 216.0 140700 11258 344.2
337 Taper 0.907 1 0.907 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
338 Taper 0.893 1 0.893 Sec. 9.3.1.1 276 216.0 140700 11258 344.2
339 Taper 0.215 1 0.215 Sec. 9.3.1.1 247 216.0 140700 11258 344.2
340 Taper 0.256 1 0.256 Sec. 9.3.1.1 268 216.0 140700 11258 344.2
341 ISMC150 0.713 1 0.713 Slenderness 221 21.3 788 102 5.4
342 Taper 0.961 1 0.961 Sec. 9.3.2.2 220 204.0 93800 11256 338.4
343 Taper 0.919 1 0.919 Sec. 9.3.2.2 220 204.0 93800 11256 338.4
344 Taper 0.287 1 0.287 Major Axis B 221 204.0 93800 11256 338.4
345 Taper 0.648 1 0.648 Major Axis B 221 204.0 93800 11256 338.4
346 Taper 0.721 1 0.721 Major Axis B 221 204.0 93800 11256 338.4
347 Taper 0.763 1 0.763 Major Axis B 221 204.0 93800 11256 338.4
348 Taper 0.855 1 0.855 Sec. 9.3.2.2 221 204.0 93800 11256 338.4
349 Taper 0.564 1 0.564 Major Axis B 221 204.0 93800 11256 338.4
350 Taper 0.831 1 0.831 Sec. 9.3.2.2 221 204.0 93800 11256 338.4
351 UB457X191X67 0.446 1 0.446 Major Axis B 221 85.5 29380 1452 37.5
352 Taper 0.357 1 0.357 Major Axis B 221 204.0 93800 11256 338.4
353 UB203X133X25 0.449 1 0.449 Slenderness 220 32.0 2340 308 6.1
354 Taper 0.357 1 0.357 Major Axis B 221 204.0 93800 11256 338.4
355 UB203X133X25 0.775 1 0.775 Sec. 9.3.2.2 222 32.0 2340 308 6.1
356 Taper 0.346 1 0.346 Major Axis B 221 204.0 93800 11256 338.4
357 UB203X133X25 0.673 1 0.673 Major Axis B 222 32.0 2340 308 6.1
358 ISMC150 0.508 1 0.508 Slenderness 221 21.3 788 102 5.4
359 ISMC200 0.475 1 0.475 Sec. 9.3.1.3 220 28.5 1830 139 9.8
360 ISMC150 0.33 1 0.33 Slenderness 221 21.3 788 102 5.4
361 ISMC200 0.759 1 0.759 Sec. 9.3.2.2 220 28.5 1830 139 9.8
362 UB457X191X67 0.28 1 0.28 Sec. 9.3.2.2 278 85.5 29380 1452 37.5
363 UB457X191X67 0.454 1 0.454 Sec. 9.3.2.2 220 85.5 29380 1452 37.5
364 Taper 0.328 1 0.328 Sec. 9.3.2.2 276 204.0 93800 11256 338.4
365 UB457X191X67 0.458 1 0.458 Sec. 9.3.2.2 220 85.5 29380 1452 37.5
366 Taper 0.281 1 0.281 Major Axis B 276 204.0 93800 11256 338.4
367 ISMC200 0.773 1 0.773 Sec. 9.3.2.2 220 28.5 1830 139 9.8
368 Taper 0.264 1 0.264 Sec. 9.3.2.2 276 204.0 93800 11256 338.4

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 105
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

369 ISMC200 0.478 1 0.478 Sec. 9.3.1.3 220 28.5 1830 139 9.8
370 UB457X191X67 0.27 1 0.27 Slenderness 221 85.5 29380 1452 37.5
371 ISMC200 0.436 1 0.436 Sec. 9.3.1.3 220 28.5 1830 139 9.8
372 Taper 0.36 1 0.36 Major Axis B 221 204.0 93800 11256 338.4
373 ISMC200 0.422 1 0.422 Sec. 9.3.1.3 220 28.5 1830 139 9.8
374 Taper 0.476 1 0.476 Sec. 9.3.2.2 221 204.0 93800 11256 338.4
375 ISMC200 0.566 1 0.566 Slenderness 221 28.5 1830 139 9.8
376 Taper 0.219 1 0.219 Major Axis B 221 204.0 93800 11256 338.4
377 UB203X133X25 0.449 1 0.449 Slenderness 221 32.0 2340 308 6.1
378 Taper 0.261 1 0.261 Sec. 9.3.2.2 291 152.2 66492 7207 108.9
379 Taper 0.657 1 0.657 Sec. 9.3.2.2 269 152.2 66492 7207 108.9
380 Taper 0.776 1 0.776 Sec. 9.3.2.2 269 152.2 66492 7207 108.9
381 Taper 0.368 1 0.368 Sec. 9.3.2.2 275 152.2 66492 7207 108.9
382 Taper 0.549 1 0.549 Sec. 9.3.2.2 275 152.2 66492 7207 108.9
383 Taper 0.424 1 0.424 Sec. 9.3.2.2 220 152.2 66492 7207 108.9
384 UB533X210X82 0.27 1 0.27 Sec. 9.3.2.2 220 104.7 47539 2007 52.5
385 UB533X210X82 0.247 1 0.247 Sec. 9.3.2.2 277 104.7 47539 2007 52.5
386 UB457X191X67 0.503 1 0.503 Sec. 9.3.2.2 277 85.5 29380 1452 37.5
387 UB533X210X82 0.446 1 0.446 Major Axis B 222 104.7 47539 2007 52.5
388 UB533X210X82 0.227 1 0.227 Major Axis B 242 104.7 47539 2007 52.5
389 UB533X210X82 0.511 1 0.511 Sec. 9.3.2.2 294 104.7 47539 2007 52.5
390 UB533X210X82 0.3 1 0.3 Sec. 9.3.2.2 240 104.7 47539 2007 52.5
391 UB457X191X82 0.982 1 0.982 Slenderness 227 104.5 37051 1871 69.7
392 UB254X146X37 0.224 1 0.224 Sec. 9.3.1.1 292 47.2 5537 571 15.4
393 UB254X146X37 0.306 1 0.306 Sec. 9.3.1.1 292 47.2 5537 571 15.4
394 UB305X165X40 0.237 1 0.237 Sec. 9.3.2.2 276 51.3 8503 764 14.7
395 UB305X165X40 0.156 1 0.156 Slenderness 220 51.3 8503 764 14.7
396 UB457X191X82 0.118 1 0.118 Slenderness 220 104.5 37051 1871 69.7
397 UC254X254X73.1 0.757 1 0.757 Shear along 220 93.1 11407 3907 57.7
398 UC254X254X73.1 0.769 1 0.769 Shear along 220 93.1 11407 3907 57.7
399 UC254X254X73.1 0.359 1 0.359 Sec. 9.3.2.2 221 93.1 11407 3907 57.7
400 UC254X254X73.1 0.674 1 0.674 Sec. 9.3.2.2 221 93.1 11407 3907 57.7
401 UC254X254X73.1 0.176 1 0.176 Sec. 9.3.2.2 268 93.1 11407 3907 57.7
402 UC254X254X73.1 0.17 1 0.17 Sec. 9.3.2.2 268 93.1 11407 3907 57.7
403 UC254X254X73.1 0.715 1 0.715 Shear along 220 93.1 11407 3907 57.7
404 UC254X254X73.1 0.726 1 0.726 Shear along 220 93.1 11407 3907 57.7
405 UC254X254X73.1 0.632 1 0.632 Sec. 9.3.1.1 293 93.1 11407 3907 57.7
406 UC254X254X73.1 0.616 1 0.616 Sec. 9.3.2.2 221 93.1 11407 3907 57.7
407 UC254X254X73.1 0.233 1 0.233 Sec. 9.3.2.2 293 93.1 11407 3907 57.7
408 ISMC150 0.919 1 0.919 Sec. 9.3.2.2 220 21.3 788 102 5.4
409 ISMC150 1.182 1 1.182 Sec. 9.3.1.3 276 21.3 788 102 5.4
410 ISMC150 1.046 1 1.046 Sec. 9.3.1.3 268 21.3 788 102 5.4
411 ISMC150 0.402 1 0.402 Sec. 9.3.1.3 268 21.3 788 102 5.4
412 UC254X254X73.1 0.469 1 0.469 Sec. 9.3.1.1 277 93.1 11407 3907 57.7
413 UC254X254X73.1 0.426 1 0.426 Sec. 9.3.1.1 293 93.1 11407 3907 57.7
414 UB533X210X82 0.541 1 0.541 Sec. 9.3.2.2 291 104.7 47539 2007 52.5
415 UB533X210X82 0.3 1 0.3 Sec. 9.3.2.2 291 104.7 47539 2007 52.5
416 UC254X254X73.1 0.356 1 0.356 Sec. 9.3.2.2 294 93.1 11407 3907 57.7
417 UC254X254X73.1 0.132 1 0.132 Sec. 9.3.1.1 240 93.1 11407 3907 57.7
418 UC254X254X73.1 0.389 1 0.389 Sec. 9.3.2.2 220 93.1 11407 3907 57.7
419 UC254X254X73.1 0.268 1 0.268 Sec. 9.3.2.2 220 93.1 11407 3907 57.7
420 UC254X254X73.1 0.282 1 0.282 Sec. 9.3.2.2 292 93.1 11407 3907 57.7
421 UC254X254X73.1 0.137 1 0.137 Major Axis B 292 93.1 11407 3907 57.7
422 UC254X254X73.1 0.106 1 0.106 Sec. 9.3.2.2 277 93.1 11407 3907 57.7
423 UC254X254X73.1 0.1 1 0.1 Slenderness 220 93.1 11407 3907 57.7
424 UC254X254X73.1 0.288 1 0.288 Sec. 9.3.2.2 292 93.1 11407 3907 57.7
425 UC254X254X73.1 0.099 1 0.099 Slenderness 221 93.1 11407 3907 57.7
426 UC254X254X73.1 0.255 1 0.255 Sec. 9.3.2.2 277 93.1 11407 3907 57.7

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 106
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

427 UC254X254X73.1 0.183 1 0.183 Sec. 9.3.2.2 220 93.1 11407 3907 57.7
428 ISMC150 0.447 1 0.447 Sec. 9.3.1.3 269 21.3 788 102 5.4
429 ISMC150 0.42 1 0.42 Sec. 9.3.1.3 277 21.3 788 102 5.4
430 ISMC150 1.001 1 1.001 Sec. 9.3.2.2 277 21.3 788 102 5.4
431 ISMC150 0.714 1 0.714 Sec. 9.3.1.3 269 21.3 788 102 5.4
432 UC254X254X73.1 0.148 1 0.148 Major Axis B 292 93.1 11407 3907 57.7
433 Taper 0.295 1 0.295 Sec. 9.3.2.2 277 136.2 57119 4173 95.2
434 Taper 0.294 1 0.294 Sec. 9.3.2.2 277 136.2 57119 4173 95.2
435 Taper 0.303 1 0.303 Sec. 9.3.1.1 277 136.2 57119 4173 95.2
436 Taper 0.88 1 0.88 Sec. 9.3.1.1 277 136.2 57119 4173 95.2
437 UB457X191X67 0.333 1 0.333 Sec. 9.3.2.2 220 85.5 29380 1452 37.5
438 Taper 0.172 1 0.172 Sec. 9.3.1.1 269 136.2 57119 4173 95.2
439 ISMC150 0.654 1 0.654 Slenderness 221 21.3 788 102 5.4
440 ISMC150 0.579 1 0.579 Slenderness 221 21.3 788 102 5.4
441 ISMC150 0.504 1 0.504 Slenderness 220 21.3 788 102 5.4
442 ISMC150 0.429 1 0.429 Slenderness 220 21.3 788 102 5.4
443 UB457X191X67 0.429 1 0.429 Sec. 9.3.2.2 220 85.5 29380 1452 37.5
444 UB457X191X67 0.442 1 0.442 Sec. 9.3.2.2 220 85.5 29380 1452 37.5
445 UB457X191X67 0.509 1 0.509 Sec. 9.3.2.2 277 85.5 29380 1452 37.5
446 UB457X191X67 0.217 1 0.217 Sec. 9.3.2.2 220 85.5 29380 1452 37.5
447 UB533X210X82 0.38 1 0.38 Sec. 9.3.2.2 294 104.7 47539 2007 52.5
448 UB203X133X25 0.197 1 0.197 Slenderness 221 32.0 2340 308 6.1
449 UB203X133X25 0.198 1 0.198 Slenderness 221 32.0 2340 308 6.1
450 UB203X133X25 0.197 1 0.197 Slenderness 220 32.0 2340 308 6.1
451 UB533X210X82 0.586 1 0.586 Sec. 9.3.2.2 277 104.7 47539 2007 52.5
452 UB203X133X25 0.197 1 0.197 Slenderness 231 32.0 2340 308 6.1
453 UB533X210X82 0.182 1 0.182 Sec. 9.3.1.1 269 104.7 47539 2007 52.5
454 ISMC150 0.467 1 0.467 Slenderness 222 21.3 788 102 5.4
455 Taper 0.136 1 0.136 Slenderness 236 136.2 57119 4173 95.2
456 Taper 0.149 1 0.149 Sec. 9.3.1.1 268 136.2 57119 4173 95.2
457 Taper 0.687 1 0.687 Sec. 9.3.1.1 269 136.2 57119 4173 95.2
458 UB533X210X82 0.244 1 0.244 Sec. 9.3.2.2 240 104.7 47539 2007 52.5
459 UB533X210X82 0.3 1 0.3 Sec. 9.3.2.2 240 104.7 47539 2007 52.5
460 ISMC150 0.542 1 0.542 Slenderness 238 21.3 788 102 5.4
461 ISMC150 0.618 1 0.618 Slenderness 220 21.3 788 102 5.4
462 UB533X210X82 0.222 1 0.222 Sec. 9.3.2.2 303 104.7 47539 2007 52.5
463 ISMC150 0.693 1 0.693 Slenderness 220 21.3 788 102 5.4
464 UB203X133X30 0.628 1 0.628 Sec. 9.3.2.2 220 38.2 2896 385 10.4
465 ISMC150 0.53 1 0.53 Slenderness 232 21.3 788 102 5.4
466 ISMC150 0.53 1 0.53 Slenderness 266 21.3 788 102 5.4
467 ISMC150 0.53 1 0.53 Slenderness 220 21.3 788 102 5.4
468 ISMC150 0.53 1 0.53 Slenderness 220 21.3 788 102 5.4
469 UB203X133X30 0.636 1 0.636 Sec. 9.3.2.2 220 38.2 2896 385 10.4
470 UB203X133X30 0.872 1 0.872 Sec. 9.3.2.2 220 38.2 2896 385 10.4
471 UB203X133X30 0.872 1 0.872 Sec. 9.3.2.2 220 38.2 2896 385 10.4
472 UB203X133X30 0.839 1 0.839 Sec. 9.3.2.2 220 38.2 2896 385 10.4
473 ISMC250 0.576 1 0.576 Sec. 9.3.1.3 269 39.0 3838 218 18.8
474 ISMC250 0.56 1 0.56 Slenderness 220 39.0 3838 218 18.8
475 ISMC250 0.268 1 0.268 Sec. 9.3.2.2 221 39.0 3838 218 18.8
476 ISMC250 0.254 1 0.254 Slenderness 220 39.0 3838 218 18.8
477 ISMC250 0.918 1 0.918 Sec. 9.3.1.3 220 39.0 3838 218 18.8
478 ISMC250 0.998 1 0.998 Sec. 9.3.1.3 220 39.0 3838 218 18.8
479 UB457X191X82 0.982 1 0.982 Slenderness 227 104.5 37051 1871 69.7

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 107
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

4.5 REACTIONS FOR BASE PLATE DESIGN

Node L/C FX kN FY kN FZ kN MX kNm MY kNm MZ kNm

1 220 195.914 661.808 173.384 0 0.16 -41.022


247 110.007 235.509 80.107 0 0.158 -21
248 158.043 363.906 83.279 0 0.167 -47.789
249 151.647 278.315 32.327 0 0.165 -42.422
250 153.801 377.456 109.019 0 0.16 -42.581
251 -6.451 117.036 61.158 0 -0.006 13.577
252 41.585 245.434 64.33 0 0.003 -13.212
253 35.189 159.842 13.379 0 0.001 -7.845
254 37.343 258.983 90.07 0 -0.004 -8.004
255 -5.246 122.791 66.882 0 -0.007 13.437
256 42.79 251.188 70.054 0 0.003 -13.352
257 36.394 165.596 19.102 0 0 -7.985
258 38.549 264.738 95.794 0 -0.004 -8.144
259 79.919 149.535 59.15 0 0.081 -9.63
260 112.088 396.631 70.722 0 0.113 -36.267
261 92.375 168.459 12.833 0 0.107 -22.721
262 99.632 377.708 117.038 0 0.087 -23.175
263 10.156 79.398 46.814 0 -0.018 11.116
264 42.325 326.494 58.385 0 0.015 -15.521
265 22.611 98.321 0.497 0 0.009 -1.975
266 29.869 307.571 104.702 0 -0.011 -2.43
267 128.097 205.991 69.069 0 0.146 -23.603
268 160.267 453.087 80.641 0 0.179 -50.24
269 140.553 224.914 22.753 0 0.172 -36.694
270 147.811 434.164 126.957 0 0.152 -37.149
295 130.609 441.205 115.589 0 0.107 -27.348
296 53.094 363.275 101.882 0 -0.002 -4.297
297 54.434 369.669 108.242 0 -0.003 -4.454
298 108.815 383.932 121.295 0 0.104 -16.828
299 140.839 469.531 123.41 0 0.11 -34.688
300 136.575 412.469 89.442 0 0.108 -31.11
301 138.011 478.564 140.57 0 0.105 -31.216
302 119.886 358.84 111.732 0 0.096 -18.469
303 141.332 523.571 119.446 0 0.118 -36.227
304 128.19 371.456 80.854 0 0.114 -27.197
305 133.028 510.955 150.324 0 0.1 -27.499
306 31.3 306.002 107.588 0 -0.006 6.223
307 63.324 391.6 109.703 0 0.001 -11.637
308 59.06 334.539 75.735 0 -0.001 -8.059
309 60.496 400.633 126.863 0 -0.004 -8.165
310 42.371 280.91 98.025 0 -0.013 4.582
311 63.817 445.64 105.74 0 0.009 -13.176
312 50.675 293.525 67.148 0 0.004 -4.146
313 55.513 433.025 136.617 0 -0.009 -4.449
314 32.639 312.396 113.948 0 -0.006 6.066
315 64.663 397.994 116.063 0 0 -11.793
316 60.399 340.933 82.095 0 -0.001 -8.215
317 61.836 407.027 133.222 0 -0.004 -8.321

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 108
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 43.711 287.303 104.385 0 -0.014 4.425


319 65.157 452.034 112.099 0 0.008 -13.333
320 52.014 299.919 73.507 0 0.004 -4.302
321 56.853 439.419 142.977 0 -0.01 -4.605
2 220 69.068 337.521 103.412 0 -0.243 -32.449
247 61.805 47.293 5.433 0 0.083 -25.577
248 193.432 -82.174 5.086 0 0.123 -55.459
249 110.608 -65.985 -48.604 0 0.066 -34.087
250 108.693 95.459 40.218 0 0.059 -34.158
251 -81.899 233.172 51.928 0 -0.064 15.288
252 49.728 103.706 51.58 0 -0.024 -14.594
253 -33.096 119.895 -2.11 0 -0.082 6.778
254 -35.01 281.338 86.712 0 -0.089 6.707
255 -83.141 239.043 58.944 0 -0.063 15.273
256 48.485 109.577 58.597 0 -0.023 -14.609
257 -34.338 125.766 4.906 0 -0.081 6.764
258 -36.253 287.209 93.728 0 -0.088 6.692
259 -45.011 201.607 17.131 0 -0.035 -4.984
260 168.869 -51.37 9.17 0 0.069 -39.969
261 65.686 -98.843 -54.303 0 0.068 -22.332
262 58.173 249.08 80.605 0 -0.034 -22.621
263 -131.361 316.081 45.021 0 -0.123 19.54
264 82.519 63.105 37.059 0 -0.02 -15.445
265 -20.665 15.631 -26.414 0 -0.021 2.192
266 -28.178 363.555 108.494 0 -0.122 1.902
267 10.779 143.441 5.525 0 0.024 -21.328
268 224.659 -109.535 -2.436 0 0.128 -56.313
269 121.476 -157.009 -65.91 0 0.127 -38.676
270 113.962 190.914 68.998 0 0.025 -38.965
295 46.045 225.014 68.941 0 -0.162 -21.633
296 -49.9 352.208 99.929 0 -0.26 5.616
297 -51.281 358.732 107.725 0 -0.26 5.6
298 7.727 254.067 76.199 0 -0.157 -12.806
299 95.478 167.756 75.968 0 -0.13 -32.727
300 40.262 178.549 40.174 0 -0.169 -18.479
301 38.986 286.178 99.389 0 -0.173 -18.526
302 -25.248 309.34 71.595 0 -0.196 -9.971
303 117.338 140.689 66.287 0 -0.127 -33.294
304 48.549 109.04 23.972 0 -0.128 -21.536
305 43.541 340.989 113.911 0 -0.196 -21.729
306 -88.218 381.261 107.187 0 -0.255 14.443
307 -0.467 294.95 106.956 0 -0.229 -5.478
308 -55.683 305.743 71.162 0 -0.267 8.77
309 -56.959 413.372 130.377 0 -0.272 8.722
310 -121.193 436.534 102.583 0 -0.295 17.277
311 21.393 267.883 97.275 0 -0.226 -6.046
312 -47.396 236.234 54.96 0 -0.226 5.712
313 -52.404 468.183 144.899 0 -0.294 5.519
314 -89.599 387.784 114.983 0 -0.255 14.427
315 -1.848 301.474 114.752 0 -0.228 -5.495
316 -57.064 312.266 78.958 0 -0.266 8.754
317 -58.34 419.895 138.173 0 -0.271 8.706

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 109
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 -122.574 443.057 110.379 0 -0.294 17.261


319 20.012 274.406 105.071 0 -0.225 -6.062
320 -48.777 242.757 62.756 0 -0.226 5.696
321 -53.785 474.706 152.695 0 -0.294 5.503
3 220 87.275 642.704 -181.346 0 -0.055 -68.237
247 1.857 102.523 -85.592 0 -0.048 -2.464
248 123.311 238.752 -87.872 0 -0.06 -128.908
249 82.664 144.694 -148.469 0 -0.055 -88.092
250 82.588 307.227 3.158 0 -0.055 -87.057
251 -53.252 141.973 -47.565 0 0.005 71.646
252 68.201 278.202 -49.844 0 -0.006 -54.798
253 27.555 184.145 -110.442 0 -0.002 -13.982
254 27.478 346.678 41.186 0 -0.001 -12.947
255 -43.829 188.286 -52.87 0 0.005 72.476
256 77.624 324.515 -55.15 0 -0.006 -53.968
257 36.978 230.458 -115.747 0 -0.001 -13.152
258 36.901 392.991 35.88 0 -0.001 -12.117
259 -31.144 91.431 -73.296 0 -0.033 39.028
260 121.835 359.402 -70.7 0 -0.033 -123.646
261 45.483 20.464 -192.381 0 -0.036 -44.234
262 45.209 430.369 48.385 0 -0.03 -40.384
263 -64.175 115.822 -49.546 0 0 83.482
264 88.804 383.792 -46.951 0 -0.001 -79.191
265 12.451 44.855 -168.631 0 -0.003 0.221
266 12.177 454.76 72.134 0 0.002 4.07
267 0.443 124.484 -90.549 0 -0.054 10.172
268 153.422 392.454 -87.953 0 -0.055 -152.502
269 77.069 53.517 -209.634 0 -0.057 -73.09
270 76.795 463.421 31.132 0 -0.052 -69.24
295 58.183 428.469 -120.897 0 -0.037 -45.491
296 21.481 455.57 -94.509 0 -0.001 3.903
297 31.952 507.028 -100.405 0 -0.001 4.825
298 14.472 356.58 -120.441 0 -0.033 0.843
299 95.441 447.4 -121.961 0 -0.041 -83.453
300 68.344 384.695 -162.359 0 -0.037 -56.243
301 68.292 493.05 -61.274 0 -0.037 -55.553
302 7.19 339.146 -121.763 0 -0.037 8.733
303 109.176 517.793 -120.032 0 -0.037 -99.716
304 58.274 291.834 -201.153 0 -0.039 -46.775
305 58.092 565.104 -40.642 0 -0.035 -44.208
306 -22.229 383.681 -94.053 0 0.003 50.237
307 58.739 474.5 -95.573 0 -0.005 -34.059
308 31.642 411.796 -135.971 0 -0.002 -6.849
309 31.591 520.151 -34.886 0 -0.001 -6.159
310 -29.512 366.247 -95.375 0 -0.001 58.127
311 72.474 544.894 -93.644 0 -0.001 -50.322
312 21.573 318.935 -174.765 0 -0.003 2.62
313 21.39 592.205 -14.254 0 0.001 5.186
314 -11.759 435.139 -99.949 0 0.003 51.158
315 69.21 525.958 -101.468 0 -0.005 -33.137
316 42.112 463.254 -141.867 0 -0.002 -5.927
317 42.061 571.609 -40.781 0 -0.001 -5.237

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 110
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 -19.041 417.705 -101.27 0 -0.001 59.049


319 82.945 596.352 -99.539 0 -0.001 -49.4
320 32.043 370.393 -180.66 0 -0.003 3.541
321 31.86 643.663 -20.149 0 0.001 6.108
4 220 24.522 582.926 -176.417 0 -0.056 -62.234
247 -3.874 177.923 -72.472 0 -0.045 -13.366
248 109.353 44.658 -72.669 0 -0.057 -133.238
249 32.176 164.853 -128.084 0 -0.051 -53.705
250 31.447 138.168 10.12 0 -0.05 -52.769
251 -64.713 243.595 -40.757 0 0.005 58.068
252 48.513 110.33 -40.954 0 -0.008 -61.804
253 -28.663 230.526 -96.369 0 -0.001 17.729
254 -29.392 203.84 41.835 0 -0.001 18.665
255 -73.689 292.469 -47.535 0 0.005 60.016
256 39.537 159.204 -47.732 0 -0.007 -59.856
257 -37.639 279.4 -103.148 0 -0.001 19.677
258 -38.368 252.714 35.057 0 -0.001 20.614
259 -46.276 300.18 -55.382 0 -0.029 36.733
260 92.721 48.694 -62.453 0 -0.033 -115.85
261 24.948 220.651 -157.764 0 -0.031 -41.316
262 21.497 128.222 39.928 0 -0.032 -37.801
263 -82.803 342.176 -36.318 0 0.001 79.577
264 56.194 90.69 -43.389 0 -0.004 -73.007
265 -11.579 262.648 -138.699 0 -0.001 1.527
266 -15.031 170.218 58.992 0 -0.002 5.043
267 -30.999 331.861 -74.723 0 -0.048 10.048
268 107.998 80.375 -81.794 0 -0.053 -142.536
269 40.226 252.333 -177.104 0 -0.05 -68.002
270 36.774 159.903 20.587 0 -0.051 -64.486
295 16.348 388.617 -117.611 0 -0.037 -41.489
296 -24.238 435.28 -96.429 0 -0.005 6.114
297 -34.211 489.585 -103.96 0 -0.004 8.279
298 -17.924 406.725 -118.214 0 -0.033 -4.967
299 57.56 317.882 -118.345 0 -0.042 -84.882
300 6.109 398.012 -155.289 0 -0.037 -31.86
301 5.623 380.222 -63.152 0 -0.037 -31.236
302 -29.984 472.446 -115.254 0 -0.036 9.372
303 62.68 304.789 -119.968 0 -0.039 -92.351
304 17.498 419.427 -183.508 0 -0.037 -42.661
305 15.198 357.807 -51.714 0 -0.038 -40.317
306 -58.51 453.388 -97.031 0 0 42.636
307 16.974 364.545 -97.162 0 -0.009 -37.278
308 -34.477 444.675 -134.106 0 -0.004 15.743
309 -34.963 426.885 -41.97 0 -0.004 16.368
310 -70.57 519.109 -94.072 0 -0.003 56.975
311 22.094 351.452 -98.786 0 -0.006 -44.747
312 -23.087 466.09 -162.326 0 -0.004 4.942
313 -25.388 404.47 -30.532 0 -0.005 7.286
314 -68.483 507.692 -104.562 0 0 44.801
315 7.001 418.849 -104.694 0 -0.008 -35.114
316 -44.45 498.98 -141.637 0 -0.004 17.908
317 -44.936 481.189 -49.501 0 -0.004 18.533

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 111
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 -80.543 573.413 -101.603 0 -0.003 59.14


319 12.121 405.756 -106.317 0 -0.006 -42.582
320 -33.061 520.394 -169.857 0 -0.004 7.107
321 -35.361 458.775 -38.063 0 -0.005 9.451
5 220 49.911 579.845 -26.582 0 -0.001 -4.668
247 -18.828 242.121 -32.114 0 0.006 35.111
248 64.049 346.965 -32.453 0 -0.007 -41.892
249 34.132 415.059 -56.907 0 -0.003 -12.72
250 32.729 153.451 32.914 0 -0.002 -13.627
251 -31.487 127.267 -12.178 0 0.007 43.096
252 51.39 232.111 -12.517 0 -0.006 -33.907
253 21.473 300.205 -36.972 0 -0.002 -4.735
254 20.07 38.597 52.85 0 -0.001 -5.642
255 -29.811 139.505 -12.423 0 0.008 43.366
256 53.066 244.349 -12.762 0 -0.006 -33.637
257 23.149 312.443 -37.216 0 -0.002 -4.465
258 21.746 50.835 52.605 0 -0.001 -5.373
259 -71.175 121.413 -16.292 0 -0.003 80.784
260 114.589 400 -12.431 0 0.002 -86.415
261 23.212 570.278 -86.358 0 -0.001 -0.764
262 20.203 -48.865 57.634 0 -0.001 -4.866
263 -79.044 52.402 -4.314 0 -0.002 85.561
264 106.721 330.989 -0.453 0 0.002 -81.638
265 15.343 501.267 -74.38 0 0 4.013
266 12.334 -117.876 69.613 0 0 -0.089
267 -65.392 179.248 -24.453 0 -0.004 77.811
268 120.372 457.835 -20.591 0 0.001 -89.388
269 28.994 628.113 -94.518 0 -0.001 -3.738
270 25.985 8.969 49.474 0 -0.001 -7.839
295 33.274 386.564 -17.722 0 0 -3.112
296 24.531 309.885 -4.412 0 0 2.196
297 26.393 323.483 -4.684 0 0.001 2.495
298 3.057 343.611 -24.251 0 0.005 24.311
299 58.309 413.508 -24.477 0 -0.004 -27.024
300 38.364 458.903 -40.78 0 -0.002 -7.577
301 37.429 284.498 19.101 0 -0.001 -8.181
302 -28.647 293.701 -19.009 0 -0.002 52.621
303 95.196 479.426 -16.434 0 0.001 -58.845
304 34.277 592.945 -65.719 0 0 -1.745
305 32.271 180.182 30.276 0 0 -4.479
306 -5.686 266.932 -10.942 0 0.005 29.618
307 49.565 336.829 -11.168 0 -0.004 -21.717
308 29.621 382.224 -27.471 0 -0.001 -2.269
309 28.686 207.819 32.41 0 0 -2.874
310 -37.39 217.023 -5.699 0 -0.001 57.929
311 86.453 402.747 -3.125 0 0.002 -53.537
312 25.534 516.266 -52.41 0 0 3.563
313 23.528 103.504 43.585 0 0 0.829
314 -3.823 280.53 -11.214 0 0.006 29.918
315 51.428 350.427 -11.44 0 -0.004 -21.417
316 31.483 395.822 -27.743 0 -0.001 -1.969
317 30.548 221.417 32.138 0 0 -2.574

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 112
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 -35.528 230.621 -5.971 0 -0.001 58.228


319 88.315 416.345 -3.397 0 0.002 -53.238
320 27.396 529.864 -52.682 0 0.001 3.863
321 25.39 117.102 43.313 0 0 1.128
6 220 -34.589 401.95 -27.15 0 -0.007 5.576
247 -40.538 219.446 -30.062 0 0 30.38
248 25.584 112.744 -30.072 0 -0.014 -38.493
249 -19.127 233.925 -46.675 0 -0.006 5.628
250 -17.159 98.874 22.764 0 -0.005 5.116
251 -43.868 181.573 -12.586 0 0.006 36.682
252 22.253 74.871 -12.596 0 -0.008 -32.192
253 -22.457 196.052 -29.199 0 0 11.929
254 -20.489 61.001 40.24 0 0.001 11.417
255 -45.955 187.655 -12.998 0 0.007 37.52
256 20.167 80.953 -13.007 0 -0.007 -31.353
257 -24.543 202.134 -29.61 0 0.001 12.768
258 -22.575 67.083 39.829 0 0.002 12.256
259 -79.632 306.082 -12.131 0 -0.005 73.885
260 53.736 17.183 -15.127 0 -0.004 -71.209
261 -16.443 289.546 -55.59 0 -0.007 2.736
262 -9.453 33.718 28.331 0 -0.002 -0.06
263 -81.35 284.519 -1.656 0 -0.001 77.544
264 52.018 -4.38 -4.652 0 0 -67.55
265 -18.161 267.983 -45.114 0 -0.003 6.395
266 -11.171 12.155 38.806 0 0.002 3.599
267 -79.407 331.375 -19.569 0 -0.007 71.776
268 53.961 42.477 -22.565 0 -0.005 -73.318
269 -16.218 314.84 -63.028 0 -0.009 0.627
270 -9.228 59.012 20.893 0 -0.004 -2.169
295 -23.06 267.967 -18.1 0 -0.005 3.717
296 -24.969 244.008 -6.461 0 0 7.783
297 -27.287 250.766 -6.918 0 0 8.714
298 -42.528 295.636 -24.388 0 0 24.84
299 1.554 224.501 -24.395 0 -0.01 -21.075
300 -28.253 305.289 -35.463 0 -0.004 8.339
301 -26.942 215.255 10.829 0 -0.004 7.997
302 -67.516 364.267 -17.102 0 -0.005 52.082
303 21.396 171.667 -19.099 0 -0.004 -44.648
304 -25.39 353.243 -46.074 0 -0.007 4.649
305 -20.73 182.691 9.873 0 -0.003 2.785
306 -44.437 271.677 -12.749 0 0.004 28.906
307 -0.356 200.542 -12.755 0 -0.005 -17.01
308 -30.163 281.33 -23.824 0 0 12.404
309 -28.851 191.296 22.468 0 0.001 12.063
310 -69.425 340.308 -5.463 0 -0.001 56.147
311 19.487 147.708 -7.46 0 0 -40.582
312 -27.299 329.284 -34.435 0 -0.002 8.715
313 -22.639 158.732 21.512 0 0.002 6.851
314 -46.755 278.435 -13.206 0 0.005 29.838
315 -2.674 207.3 -13.212 0 -0.005 -16.078
316 -32.481 288.087 -24.281 0 0.001 13.336
317 -31.169 198.054 22.011 0 0.001 12.995

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 113
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 -71.743 347.065 -5.919 0 0 57.079


319 17.169 154.466 -7.917 0 0.001 -39.65
320 -29.617 336.042 -34.892 0 -0.002 9.646
321 -24.957 165.49 21.055 0 0.002 7.782
113 220 0 9.946 0 0 0 0
247 0 1.428 0 0 0 0
248 0 1.422 0 0 0 0
249 0 1.33 0 0 0 0
250 0 1.554 0 0 0 0
251 0 1.796 0 0 0 0
252 0 1.791 0 0 0 0
253 0 1.698 0 0 0 0
254 0 1.922 0 0 0 0
255 0 1.756 0 0 0 0
256 0 1.75 0 0 0 0
257 0 1.657 0 0 0 0
258 0 1.882 0 0 0 0
259 0 1.659 0 0 0 0
260 0 1.47 0 0 0 0
261 0 1.331 0 0 0 0
262 0 1.799 0 0 0 0
263 0 1.882 0 0 0 0
264 0 1.693 0 0 0 0
265 0 1.553 0 0 0 0
266 0 2.021 0 0 0 0
267 0 1.477 0 0 0 0
268 0 1.288 0 0 0 0
269 0 1.148 0 0 0 0
270 0 1.617 0 0 0 0
295 0 6.63 0 0 0 0
296 0 6.878 0 0 0 0
297 0 6.833 0 0 0 0
298 0 6.637 0 0 0 0
299 0 6.633 0 0 0 0
300 0 6.571 0 0 0 0
301 0 6.721 0 0 0 0
302 0 6.693 0 0 0 0
303 0 6.567 0 0 0 0
304 0 6.474 0 0 0 0
305 0 6.787 0 0 0 0
306 0 6.884 0 0 0 0
307 0 6.88 0 0 0 0
308 0 6.818 0 0 0 0
309 0 6.968 0 0 0 0
310 0 6.941 0 0 0 0
311 0 6.815 0 0 0 0
312 0 6.722 0 0 0 0
313 0 7.034 0 0 0 0
314 0 6.839 0 0 0 0
315 0 6.835 0 0 0 0
316 0 6.773 0 0 0 0
317 0 6.923 0 0 0 0

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 114
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 0 6.896 0 0 0 0
319 0 6.77 0 0 0 0
320 0 6.677 0 0 0 0
321 0 6.989 0 0 0 0
114 220 0 3.63 0 0 0 0
247 0 0.264 0 0 0 0
248 0 0.233 0 0 0 0
249 0 0.165 0 0 0 0
250 0 0.166 0 0 0 0
251 0 0.77 0 0 0 0
252 0 0.739 0 0 0 0
253 0 0.671 0 0 0 0
254 0 0.672 0 0 0 0
255 0 0.761 0 0 0 0
256 0 0.729 0 0 0 0
257 0 0.662 0 0 0 0
258 0 0.663 0 0 0 0
259 0 0.45 0 0 0 0
260 0 0.347 0 0 0 0
261 0 0.47 0 0 0 0
262 0 0.326 0 0 0 0
263 0 0.754 0 0 0 0
264 0 0.65 0 0 0 0
265 0 0.774 0 0 0 0
266 0 0.63 0 0 0 0
267 0 0.239 0 0 0 0
268 0 0.135 0 0 0 0
269 0 0.259 0 0 0 0
270 0 0.115 0 0 0 0
295 0 2.42 0 0 0 0
296 0 2.757 0 0 0 0
297 0 2.747 0 0 0 0
298 0 2.465 0 0 0 0
299 0 2.444 0 0 0 0
300 0 2.399 0 0 0 0
301 0 2.4 0 0 0 0
302 0 2.454 0 0 0 0
303 0 2.385 0 0 0 0
304 0 2.468 0 0 0 0
305 0 2.372 0 0 0 0
306 0 2.803 0 0 0 0
307 0 2.782 0 0 0 0
308 0 2.737 0 0 0 0
309 0 2.737 0 0 0 0
310 0 2.792 0 0 0 0
311 0 2.723 0 0 0 0
312 0 2.805 0 0 0 0
313 0 2.709 0 0 0 0
314 0 2.792 0 0 0 0
315 0 2.771 0 0 0 0
316 0 2.726 0 0 0 0
317 0 2.727 0 0 0 0

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 115
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

318 0 2.781 0 0 0 0
319 0 2.712 0 0 0 0
320 0 2.795 0 0 0 0
321 0 2.699 0 0 0 0

4.6 DESIGN OF BASE PLATE

1 F1 F1

SRC-01

F2

F1
F1
2 CV-09

F1 F1
3

CV-08
B A

Base Plate Notation

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 116
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

4.6.1 Base Plate Design BP-1 For Column UB305X305X97 (F1)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 117
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 118
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 119
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 120
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 121
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 122
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 123
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 124
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 125
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 126
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 127
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 128
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 129
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 130
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 131
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 132
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 133
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 134
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 135
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

4.6.2 Base Plate Design BP-2 For Column ISMC250 (F2)

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 136
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 137
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

4.7 REACTIONS FOR FOUNDATIONS

1
NODE:02
NODE:01

SRC-01

NODE:113 NODE:114

NODE:03
CV-09
2 NODE:04

NODE:05
3
NODE:06

CV-08
B A
Node Number Location

DEAD LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 1 17.76 156.21 31.74 0.00 0.00 -1.18
2 1 -15.80 137.90 21.24 0.00 -0.08 2.37
3 1 4.67 173.93 -28.06 0.00 0.00 1.02
4 1 -5.84 157.85 -20.59 0.00 0.00 1.28
5 1 9.66 139.14 -1.62 0.00 0.00 1.02
6 1 -10.44 123.18 -2.71 0.00 0.00 3.03
113 1 0.00 2.10 0.00 0.00 0.00 0.00
114 1 0.00 0.81 0.00 0.00 0.00 0.00

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 138
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

EQUIPMENT LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 2 10.96 61.00 26.28 0.00 0.00 -1.27
2 2 -10.87 64.33 24.20 0.00 0.00 -0.11
3 2 8.86 95.36 -25.14 0.00 0.00 1.36
4 2 -8.78 74.42 -23.58 0.00 0.00 2.38
5 2 5.45 65.43 -0.98 0.00 0.00 1.15
6 2 -5.61 24.11 -0.77 0.00 0.00 2.52
113 2 0.00 -0.12 0.00 0.00 0.00 0.00
114 2 0.00 -0.03 0.00 0.00 0.00 0.00

MATERIAL LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 3 0.13 5.66 3.11 0.00 0.00 0.00
2 3 -0.10 0.25 0.19 0.00 0.00 0.01
3 3 0.06 6.27 -3.00 0.00 0.00 0.04
4 3 -0.09 1.01 -0.21 0.00 0.00 0.04
5 3 1.03 8.70 -0.09 0.00 0.00 0.06
6 3 -1.02 5.11 0.00 0.00 0.00 0.35
113 3 0.00 0.00 0.00 0.00 0.00 0.00
114 3 0.00 0.00 0.00 0.00 0.00 0.00

LIVE LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 4 23.94 137.78 43.44 0.00 0.00 -1.85
2 4 -22.77 141.55 54.33 0.00 -0.18 3.34
3 4 7.80 178.01 -40.90 0.00 0.00 1.52
4 4 -9.46 194.80 -52.15 0.00 0.00 2.46
5 4 9.16 96.89 -1.76 0.00 0.00 0.02
6 4 -8.67 88.38 -2.96 0.00 0.00 2.23
113 4 0.00 4.89 0.00 0.00 0.00 0.00
114 4 0.00 1.98 0.00 0.00 0.00 0.00

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 139
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

WIND LOAD +X DIRECTION

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 5 -21.79 -57.27 5.71 0.00 0.00 10.52
2 5 -38.32 29.05 7.26 0.00 0.01 8.83
3 5 -43.71 -71.89 0.46 0.00 0.00 46.33
4 5 -34.27 18.11 -0.60 0.00 0.00 36.52
5 5 -30.22 -42.95 -6.53 0.00 0.01 27.42
6 5 -19.47 27.67 -6.29 0.00 0.00 21.12
113 5 0.00 0.01 0.00 0.00 0.00 0.00
114 5 0.00 0.05 0.00 0.00 0.00 0.00

WIND LOAD -X DIRECTION

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 6 10.23 28.33 7.82 0.00 0.00 -7.34
2 6 49.43 -57.26 7.03 0.00 0.03 -11.09
3 6 37.26 18.93 -1.06 0.00 0.00 -37.96
4 6 41.21 -70.74 -0.73 0.00 0.00 -43.39
5 6 25.03 26.94 -6.76 0.00 0.00 -23.91
6 6 24.61 -43.47 -6.29 0.00 -0.01 -24.79
113 6 0.00 0.00 0.00 0.00 0.00 0.00
114 6 0.00 0.02 0.00 0.00 0.00 0.00

WIND LOAD +Z DIRECTION

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 7 5.97 -28.74 -26.15 0.00 0.00 -3.76
2 7 -5.78 -46.47 -28.77 0.00 -0.01 3.15
3 7 10.16 -43.77 -41.46 0.00 0.00 -10.75
4 7 -10.24 9.40 -37.68 0.00 0.00 9.63
5 7 5.09 72.34 -23.06 0.00 0.00 -4.47
6 7 -5.19 37.32 -17.36 0.00 0.00 4.62
113 7 0.00 -0.06 0.00 0.00 0.00 0.00
114 7 0.00 -0.02 0.00 0.00 0.00 0.00

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 140
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

WIND LOAD - Z DIRECTION

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 8 7.40 37.36 24.98 0.00 0.00 -3.87
2 8 -7.06 61.16 30.45 0.00 -0.01 3.11
3 8 10.11 64.58 59.62 0.00 0.00 -10.06
4 8 -10.73 -8.40 54.46 0.00 0.00 10.25
5 8 4.16 -102.07 36.82 0.00 0.00 -5.07
6 8 -3.88 -52.71 28.93 0.00 0.00 4.28
113 8 0.00 0.09 0.00 0.00 0.00 0.00
114 8 0.00 -0.02 0.00 0.00 0.00 0.00

SEISMIC LOAD +X DIRECTION

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 9 -10.72 -82.37 -3.86 0.00 -0.01 8.88
2 9 -71.29 84.33 2.65 0.00 -0.03 11.66
3 9 -50.99 -89.32 -0.87 0.00 0.00 54.23
4 9 -46.33 83.83 2.36 0.00 0.00 50.86
5 9 -61.92 -92.86 -1.29 0.00 0.00 55.73
6 9 -44.46 96.30 1.00 0.00 0.00 48.37
113 9 0.00 0.06 0.00 0.00 0.00 0.00
114 9 0.00 0.04 0.00 0.00 0.00 0.00

SEISMIC LOAD +Z DIRECTION

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 10 -2.42 -69.75 -34.74 0.00 0.01 0.15
2 10 2.50 -115.97 -44.97 0.00 0.03 0.10
3 10 0.09 -136.64 -80.26 0.00 0.00 -1.28
4 10 1.15 30.81 -65.90 0.00 0.00 -1.17
5 10 1.00 206.38 -48.00 0.00 0.00 1.37
6 10 -2.33 85.28 -27.97 0.00 0.00 0.93
113 10 0.00 -0.16 0.00 0.00 0.00 0.00
114 10 0.00 0.05 0.00 0.00 0.00 0.00

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 141
V.O.CHIDAMBARANAR PORT TRUST
Project Design .by R.S.R Dtd. 17/07/13
NORTH CARGO BERTH-II, TUTICORIN PORT
Doc. Title Analysis & Design of Transfer Tower-JTT-6 Checked by Dtd.
Doc. No. 19260009-CAL-ME–JTT6-0001 Rev. No 0 Aprd. by Dtd.

BELT TENSION LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 11 77.82 80.56 11.02 0.00 0.11 -23.05
2 11 95.59 -119.01 -31.01 0.00 0.10 -27.24
3 11 36.80 -25.10 -23.80 0.00 -0.04 -49.43
4 11 40.52 -39.46 -21.09 0.00 -0.03 -47.65
5 11 7.98 76.41 -13.26 0.00 0.00 -5.35
6 11 2.69 27.18 -11.67 0.00 0.00 -4.40
113 11 0.00 -0.24 0.00 0.00 0.00 0.00
114 11 0.00 -0.34 0.00 0.00 0.00 0.00

MONO RAIL LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 12 0.44 8.29 0.43 0.00 0.00 0.00
2 12 -0.46 8.43 0.17 0.00 0.00 0.02
3 12 0.16 8.28 -0.41 0.00 0.00 0.00
4 12 -0.16 8.21 -0.11 0.00 0.00 -0.01
5 12 0.27 8.43 -0.05 0.00 0.00 0.02
6 12 -0.25 8.34 -0.03 0.00 0.00 0.01
113 12 0.00 0.00 0.00 0.00 0.00 0.00
114 12 0.00 0.00 0.00 0.00 0.00 0.00

MATERIAL JAMMING LOAD

FX FY FZ MX MY MZ
Node L/C
kN kN kN kN-m kN-m kN-m
1 13 1.78 14.68 6.79 0.00 0.00 -0.16
2 13 -1.84 14.96 7.97 0.00 0.00 0.00
3 13 10.63 59.73 -6.31 0.00 0.00 0.93
4 13 -10.13 62.52 -7.64 0.00 0.00 2.16
5 13 2.13 22.03 -0.32 0.00 0.00 0.32
6 13 -2.57 15.10 -0.49 0.00 0.00 0.94
113 13 0.00 -0.04 0.00 0.00 0.00 0.00
114 13 0.00 -0.01 0.00 0.00 0.00 0.00

****END OF DESIGN SUMMARY REPORT OF TRANSFER TOWER JTT-06****

Analysis & Design of Conveyor – Transfer tower JTT06 (TUTICORIN PORT) Page 142