Welcome to the release of FSIM Plus® Software version 4.7. These Release Notes
supplement the FSIM Plus version 4.7 software documentation supplied with this release.
They detail important notices, software compatibility, supported hardware configurations,
new features and resolved defects for FSIM Plus software.
FSIM Plus software is a combination of an Intelligent Automation (I/A) Series™
software with FSIM Plus software and a process-modeling package. The instrument and
control signals that link the two pieces together are managed with the cross-reference
database utility that is built into the Graphical User Interface.

Contents
Release Notes for FSIM Plus® Software Version 4.7 ...................................................... 1
Contents ...................................................................................................................... 1
Important Notices ............................................................................................................ 2
Installation Infrastructure Notice ................................................................................. 2
General Upgrade Notes................................................................................................ 2
Upgrade from prior FSIM Plus software versions ........................................................ 3
Patch Kit Installation Location Notice ......................................................................... 3
FSIM Plus Support for SOE and TDR / TDA .............................................................. 3
FAIM and AIM*® API Support .................................................................................. 3
Other Foxboro I/A Series Software Compatibility Notes: ............................................ 4
FSIM Plus 4.7 Software Compatibility ........................................................................ 4
Windows® OS Security Information ........................................................................... 6
Hardware Requirements for PC ................................................................................... 6
Single-Box Configuration ............................................................................................ 6
Multi-Box Configuration ............................................................................................. 6
Foxboro Control Software (FCS) Support .................................................................... 7
Optional Graphical User Interface/Instructor Station PC .............................................. 8
I/A Series Supported Control Blocks supported by FSIM Plus 4.7 Software ................ 8
FSIM Plus 4.7 Software Installation .............................................................................. 10
Pre-Install Checklist .................................................................................................. 10
Summary of New Features in FSIM Plus 4.7 Software Release ..................................... 11
Summary of Defects Resolved in FSIM Plus 4.7 Software Release. ............................... 11
Summary of Enhancements in FSIM Plus 4.7 Software Release. ................................... 13
Notable simulator migration issues FSIM Plus 4.7 Software Release. ............................ 13
Where to Find FSIM Plus Documentation ..................................................................... 14
License and Copyright Information ............................................................................... 15

1
RELEASE NOTES

Important: Read First

Important Notices

Installation Infrastructure Notice

FSIM Plus software version 4.7 works only with I/A Series™ 8.7 legacy security,
FoxView™ / FoxDraw™ (FV/FD) 10.2.3, and DYNSIM® 4.5(.x) versions. The FSIM
Plus software version 4.7 operation under the I/A Series 8.7 Cyber Secure environment is
under review as a possible future FSIM Plus software feature. For simulation with earlier
DYNSIM software versions or earlier I/A Series software releases refer to the
compatibility table in the body of this document. Consult compatibility table updates for
future software versions through technical support to determine future version DYNSIM
software and TRISIM Plus® software compatibility with FSIM Plus software.

There are two options available to prepare an I/A Series 8.7 system for FSIM Plus 4.7
software installation beginning with DYNSIM version 4.5 software.

1 - In a multi-host simulator system, you may use the Activation Manager 1.0 installer on
selected host machines when only FSIM, SimSync, or TRISIM engines will be installed
on that host. When this option is used, the DYNSIM engines and DYNSIM software User
Interface will NOT be installed. You may later add version compatible DYNSIM
infrastructure and DYNSIM engines if you choose. Note that a full DYNSIM
infrastructure install must be on at least one host machine in the simulator to provide a
simulator SQL data base host and Naming Service. The full DYNSIM software installer
is the only means of installing the SQL data base host, Dynamic Simulation Suite (DSS)
Naming Services, DYNSIM User Interface and DYNSIM engines.

2 – As in prior versions, you may install DYNSIM software 4.5.x with the FSIM
Plus/TRISIM Plus software installation option as a prerequisite to installing FSIM Plus
software. This option will install the DYNSIM User Interface with menus specific to
FSIM Plus in the DYNSIM user interface as well as all Dynamic Simulation System
components including fully functional Activation Manager 1.0 components. If you use
this option you do NOT need to separately install Activation Manager 1.0.

You may install FSIM Plus 4.7 software, DYNSIM 4.5(.x) software, and Activation
Manager 1.0 in any order but I/A Series 8.7 software must be installed first. Note that
installing both DYNSIM 4.5(.x) software and Activation Manager 1.0 is redundant
though harmless.

General Upgrade Notes


We recommend using SysDef 2.11 included with I/A version 8.7 software. Only SysDef
2.10, or later versions, can be used to configure I/A Series software systems to include
simulation. Do not attempt to use any earlier version of SysDef.

2
RELEASE NOTES

Important: Read First

Snapshots saved in versions before FSIM Plus v4.7 software cannot be upgraded.

Upgrade from prior FSIM Plus software versions


The I/A Series 8.7 software install is applied to the pre-installed I/A Series 8.5 system.
Note that I/A Series 8.5 is a Day 0 release that involves significant changes to the I/A
Series base operating system. Upgrade of existing workstations to I/A Series 8.5 software
will also need to upgrade the underlying operating system.

Patch Kit Installation Location Notice


All future patch install kits will only be found on the web site:
http://iom.invensys.com/EN/Pages/home.aspx under support. You will need an
authorization code to access the FSIM Plus Electronic Software Distribution (ESD) and
Knowledge Base area.

FSIM Plus Support for SOE and TDR / TDA


FSIM Plus version 4.7 software continues support for the legacy I/A Series Sequence of
Events (SOE) that uses the EVENT block. The legacy SOE implementations that make
use of FoxGuard / ACM are not supported. FSIM Plus version 4.7 software does not
support the new I/A Series SOE application which uses AIM* with FBM207 and
FBM217.

If using a TRISIM engine with FSIM Plus software, the Triconex SOE is not supported.

FSIM Plus software does not support Transient Data Recorder / Transient Data Analyzer
(TDR / TDA).

FAIM and AIM*® API Support


FAIM supports historical trending in FoxView / Display Manager and alarm history in
FoxAlert. Additionally, FAIM supports the browser interfaces in FoxDraw, Message
Manager Configurator and other similar applications.

FAIM does not provide a complete implementation of AIM*API and will not support
AIM* client applications such as AIM*Explorer, AIM*DataLink and the AIM*Historian
tools such as the historian configurator, etc.

Users requiring AIM* client applications in a simulation environment should use the
actual AIM* Historian and its associated applications. In this instance, management of
trend and alarms for snapshots and time synchronization with the simulation cannot be
supported.

3
RELEASE NOTES

Important: Read First

Note: It is not possible to have FAIM and AIM*Historian running on the same
workstation at the same time.

Other Foxboro I/A Series Software Compatibility Notes:


• I/A Series Quick Fixes are not supported in FSIM Plus version 4.7 software.
• IACC 2.4 is supported, with the exception that ISCM not configurable with I/A
Series 8.7. This limitation resides with I/A Series software, not FSIM Plus.
• FSIM Plus version 4.7 software supports FoxView/FoxDraw (FVFD) version
10.2.3. Other FVFD versions are not supported.
• Foxboro Control Software 3.1 software is not supported with the simulation time
management functionality for InTouch. Simulation components for time
management include simulation support for alarms (CAD) or trends (AIM* /
FAIM). When InTouch HMI is required, it will function without the time
management. Due to this limitation, alarms will not restore in a snapshot and
trends will flat-line when the model is frozen.

FSIM Plus 4.7 Software Compatibility


FSIM Plus 4.7 software is compatible only with the following software:
• OS images for Windows XP SP3 or Windows Server 2003 SP2 as delivered with
P90/P91/P92 or found at buyautomation.com
• I/A Series version 8.7 software
• FoxView/FoxDraw 10.2.3 software
• DYNSIM 4.5.x software
TRISIM Plus 2.1 software (with TriStation 1131 v4.0-4.9 software)

4
RELEASE NOTES

Important: Read First

DSS Compatibility Matrix as of January 31, 2012


FSIM Plus FCS I/A Series FVFD IACC InFusion/ DYNSIM TRISIM TriStation Hardware FSIM Plus Dynsim / Logic
Simulation (1) Foxboro Control Plus 1131 OS TRISIM OS Validator
Software
4.3.4 8.2 / 8.3 10.0 2.3+ 1 4.2.2-4.2.6 1.7.3 4.0-4.3 P90/P91/P92 Win XP 2000 SP4+/XP
SP2/Server 2003 SP1&2/Server 2003
4.4 1.0 8.4 10.1 2.3+ 1.1 SP 1 4.3-4.3.1 1.8 4.0-4.4 P90/P91/P92 Win XP XP SP1&2/ Server
SP2/Server 2003 2003
4.4.1 8.4.1 10.2 2.3.1 SP1 1.1 SP 2 / 3 / 4 4.3-4.3.2, 1.8 4.0-4.4 P90/P91/P92 Win XP XP SP1&2/ Server
(Requires Dynsim SP2/Server 2003 2003
QF1011084) Checkout 4.3
4.4.2 8.4.2 10.2 2.3.1 SP1 1.2 and 1.2.1 4.3-4.3.2, 1.9 4.0-4.5 P90/P91/P92 Win XP XP SP1&2/ Server
Dynsim SP2/Server 2003 2003
Checkout 4.3
4.4.3R2 8.4.3 10.2 (3) 2.3.1 SP1 (2) 1.2.2 4.3-4.3.2, 1.9 / 1.10 4.0-4.5 P90/P91/P92 Win XP XP SP1&2/ Server
Dynsim SP2/Server 2003 2003
Checkout 4.3
4.4.4R2 8.4.3 10.2 (3) 2.3.1 SP1 (2) 1.2.2 4.4-4.4.1 1.9.1 4.0-4.5 P90/P91/P92 Win XP SP2/3 / XP SP2/3 / Server
Server 2003 SP1/2 2003 SP1/2
4.5 8.5 (4) 10.2.2 2.3.1 SP1 (2) 2 4.5.x 2.0-2.1 4.0-4.7 P90/P91/P92 Win XP SP3 / XP SP2/3 / Server 1.0 (7)
Server 2003 2003 SP1/2
SP2(6)
4.5.1R1 8.5 (4) 10.2.2 2.3.1 SP1 (2) 2 4.5.x 2.0-2.1 4.0-4.7 P90/P91/P92 Win XP SP3 / XP SP2/3 / Server 1.0 (7)
Server 2003 2003 SP1/2
SP2(6)
4.6 3.0 8.6 (4) 10.2.2 2.4 2.5 4.5.x 2.0-2.1 4.0-4.8 P90/P91/P92 Win XP SP3 / XP SP2/3 / Server 1.0 (7)
Server 2003 SP2 2003 SP1/2 (5)
4.7 8.7 (4) 10.2.3 2.4 3.1 4.5.x 2.0-2.1 4.0-4.9 P90/P91/P92 Win XP SP3 / XP SP2/3 / Server 1.0 (7)
Server 2003 SP2 2003 SP1/2 (5)

Notes
1 FSIM on Solaris I/A environment is no longer actively supported.
2 ISCM Not Configurable with I/A 8.4.3+.
3 FVFD V10.2.1 release will function without simulation support for Trends and Alarms.
4 I/A 8.5(+) / FSIM Plus 4.5(+) require an updated OS specific to I/A Series V8.5 Security Enhancements.
®
5 Dynsim V4.5.3 and TRISIM Plus 2.1 function with Windows 7 32-bit emulation mode.
6 InFusion 3.1 onwards is known as Foxboro Control Software (Applies to InFusionSIM also).
7 DYNSIM 4.5.5 with customization required

5
RELEASE NOTES

Important: Read First

Windows® OS Security Information


Install only Invensys approved Microsoft Security Patches on the FSIM Plus or AW computers.
Download the latest patch information from the IPS Support website (valid login name required):

http://support.ips.invensys.com

 Navigate to Support/Security/IA Security Patches


 On the left hand side, select the appropriate OS
 Install only approved patches

Hardware Requirements for PC


The hardware and software listed below is the only supported configuration. Refer to the FSIM Plus
Installation Guide for details.
• One or more I/A Series Foxboro AW
 Application Workstation (AW) Model P90 running on Windows Server 2003 SP 2 with the
I/A Series 8.7 software installed and only I/A approved security patches.
 Application Workstation (AW) Model P91 running on Windows Server 2003 SP 2 with the
I/A Series 8.7 software installed and only I/A approved security patches.
 Application Workstation (AW) Model P92 running on Windows XP SP 3 with the I/A
Series 8.7 software installed and only I/A approved security patches.
• Optional: Foxboro Control Software 3.1. No other patches or other versions of FCS are
supported.
• 1 GB memory or the minimum memory requirements listed in I/A documents for physical
P90/P91/P92 hardware and software. For FCS systems, 4 GB memory is required.
• Any combination of the following:
 Two I/A supported Network Interface Cards (NICs)
 Two Microsoft Loopback Adaptors
• Two I/A supported Switches (with three or more AWs/FSIM Stations)
Single-Box Configuration
For a single-box configuration, only the Application Workstation (AW), model P90, P91, or P92 is
needed. The AW requires I/A Series 8.7 software.

Multi-Box Configuration
For a multi-box configuration, at least two computers are needed: the AW and the FSIM Plus computer.
Both computers must be model P90, P91, or P92, purchased from www.BuyAutomation.com. The

Page 6 of 15
RELEASE NOTES

Important: Read First

AW requires the I/A Series 8.7 software to be purchased with the hardware. The FSIM Plus machine
requires only the P90, P91, or P92 computer, but must be installed with the I/A software prior to
installing FSIM Plus. The FSIM Plus computer can be installed using the AW software purchased
with the AW. Additional licensing is not required, unless the FSIM Station is used as an AW to view
FoxView or additional Detail Displays.

Note: The FSIM Plus 4.7 software must be installed on the AW computer.

Foxboro Control Software (FCS) Support


FSIM Plus 4.7 software will support control block emulation in Foxboro Control Software 3.1,
formerly titled InFusion. Note that FCSSIM 3.0 is compatible with FCS 3.0, I/A Series 8.6, and FSIM
Plus 4.6 only and is not compatible with I/A Series 8.7 software nor FSIM Plus 4.7 software due to this
limitation. InFusionView / InTouch trends and Process Alarms will not respond to changes in
simulated time for simulator actions such as snapshots, freeze/run in Foxboro Control Software 3.1.
There are a number of restrictions in the application of Foxboro Control Software , such as certain
functions and packages must run on dedicated servers and that some systems must use Windows 2003
based servers rather than XP workstations. Following is a list of operational recommendations:
• The Galaxy Repository should reside on its own dedicated P90/P91, Windows 2003 Server
• The Wonderware Historian should be on its own dedicated P90/P91, Windows 2003 Server
• Wonderware Historian Client for the Wonderware Historian Server should be on its own
dedicated P92, Windows XP or P90/P91 Windows 2003 machine. This machine should NOT
be used as an operator workstation.
• Each operator workstation should use a P90, P91, or P92 workstation. P90/P91 workstations
support a single monitor only. P92 workstations support multi-screen.
• If required, dedicated P92 workstations should be used for any custom App Objects.
• A dedicated P92 workstation should be used for any additional IO / DA Servers.
• If required, a dedicated P90/P91 workstation should be used for running Suite Voyager.

Invensys provides a number of example FCS configurations that adhere to the above operational
recommendations in the Foxboro Control Software Deployment Guide, B0750BA.

Note that while the example configurations show FCS running on a different workstation than the
operator workstation running either Wonderware InTouch software or FoxView software, it is possible
to run them on the same workstation.
Note: Invensys does NOT support a single box setup for an FCS platform. For non-FCS I/A
Series configurators, FSIM Plus simulators with less than 6 CPs, single box configurations
have been used with limitations in performance.

Page 7 of 15
RELEASE NOTES

Important: Read First

Optional Graphical User Interface/Instructor Station PC


An optional computer can be used as the Instructor Station Interface. For this system, the minimum
hardware requirement is an Intel® Pentium III / 650 MHz with 768 MB of RAM with Windows XP
Professional SP2+. Lower speed or lesser amounts of RAM will lead to degradation in performance.

I/A Series Supported Control Blocks supported by FSIM Plus 4.7 Software
FSIM Plus supports a variety of platform specific blocks, including blocks/ECBs. Additional details
are listed in the FSIM Plus User Guide. In general, these platforms are supported by FSIM Plus:

• CP270
• CP60
• CP40
• CP30
• CP10
• Modbus
• Tricon

For FSIM Plus 4.7, the following features are supported for compatibility with I/A Series 8.7.

1. 100 to 200 Series FBM migration blocks for simulation compatibility with I/A Series 8.7.
2. Universal FBM Blocks for simulation compatibility with I/A Series 8.7.
3. Controls block algorithms modified by I/A Series 8.7 supported for simulation compatibility.
Refer to I/A Series 8.7 Release Notes and Software Installation Guide, section 2.6 Additions
and Changes to Control Block and Parameter Software and Documentation (B0700SE).

I/A Series 8.2 through 8.7 AW has limited capability to display some blocks and ECBs using FoxView
10.2.3, including:
• Micro I/A
• ECB 15, 16, 20, 40, and 85 – 100
• ABScan

The following blocks or platforms are not supported by FSIM Plus.


• MRIN (loads but does not process)
• MROUT (loads but does not process)
• PLCIO (loads but does not process)
• Interspec Integration Blocks
• Spectrum Integration Blocks
• Instrument Gateway Blocks
• SCADA Platform

Page 8 of 15
RELEASE NOTES

Important: Read First

• Allen-Bradley Station
• PIDFF
• UNIVFF

Page 9 of 15
RELEASE NOTES

Important: Read First

FSIM Plus 4.7 Software Installation


FSIM Plus 4.7 requires that Activation Manager 1.0 be pre-installed. You may install Activation
Manager 1.0 separately or install the DYNSIM 4.5.x software full infrastructure. DYNSIM 4.5.x
software installer includes the Activation Manager 1.0 components. Refer to the DYNSIM 4.5.x
Release notes for installation details.

Pre-Install Checklist
This section lists the most common obstacles encountered by users when installing FSIM Plus. Before
you begin a new FSIM Plus install:

1. FSIM Plus software does not support having multiple versions of FSIM Plus installed
on the same machine.
2. FSIM Plus software (Dynamic Simulation Suite) does NOT support 64 bit operating
systems, Windows XP Home Edition, XP Starter Edition, ME, and Windows 98.

FSIM Plus 4.7 software must run on an I/A P90, P91, or P92 purchased from the
BuyAutomation and pre-installed with I/A partitioning and I/A users.

3. I/A Series 8.5 and 8.7 software must be installed before installing FSIM Plus 4.7
software, Activation Manager 1.0 or DYNSIM 4.5 software.
4. DYNSIM 4.5 software and/or Activation Manager 1.0 may be installed prior to, or after,
installing FSIM Plus 4.7 software. If installing DYNSIM, select the DYNSIM installer
option FSIM Plus/TRISIM Plus Core infrastructure installation option to create the
FSIM menu items in the DYNSIM user interface.
5. FSIM Plus software install testing has been performed only on I/A released operating
system media.
 Microsoft Windows XP PRO SP3 – US English
 Microsoft Windows Server 2003 SP2 – US English
Operating systems not explicitly tested are currently not supported.
6. Machine names should only include characters (A to Z) and (0 to 9). The machine
name must be six digits, all capital letters (i.e., ESS123).
7. If you have a firewall installed, it may interfere with the DSS Activation Service
Manager. You will need to put the firewall in "learning mode" the first time you start
up FSIM Plus or allow it to start various FSIM Plus processes with dynamic port
addresses. Note: Windows XP and Server 2003 include a Firewall/Internet Connection
Sharing (ICS) service that will interfere with the FSIM Plus services.
8. Data Execution Prevention may cause DYNSIM services and installer to be unreliable.
The options may be controlled from System Properties (right click on my computer)
Select: Advanced Tab -> Performance Options->Settings->Data Execution Prevention
Tab. The options are:

Page 10 of 15
RELEASE NOTES

Important: Read First

 “Turn on DEP for all programs and services except those I select” (Windows
2003 default)
 “Turn on DEP for essential Windows programs and services only” (Windows
XP default)
We recommend using the option “Turn on DEP for essential Windows programs and
services only”. Additional information may be found on Microsoft Knowledge Base
Article 875352.

Un-Installing and Re-Installing FSIM Plus V4.x Software


Refer to the FSIM Plus Installation Guide for details on uninstalling and reinstalling FSIM Plus
software.

Summary of New Features in FSIM Plus 4.7 Software Release

 I/A Series 8.7 software compatible (without Cyber security upgrade)

Summary of Defects Resolved in FSIM Plus 4.7 Software Release.

CR and feature Description

SC2#120 There is a new command line argument for engines, -


minimum_cycle_time X, where X is in milliseconds. The
problem is that some engines are completing their calculation
cycle and sending their XREF data before other engines even
receive the command to start the cycle. The command line
argument ensured that an engine takes some minimum amount
of time before it sends its XREF data. Note that if the engine
calculations already take longer than the minimum time no extra
time is added

HIFS#292 While populating cross reference for PACKIN/PACKINR and


PACKOUT points, the Input/Output addresses should be
included after the colon
HIFS#330 In the sysdef software, the letterbug assigned to the station gets
sorted, in alphabetical and numerical and alpha-numerical order,
depending on the name assigned. This causes the ICC issue in
Page 11 of 15
RELEASE NOTES

Important: Read First

the AW. Since the user faces” ICC cannot open the FSIM
stations issue”, the Documentation the FSIM Plus installation
Guide section 7.10.2 Step 2 is updated to follow the
Workaround.
HIFS#333 FSIM Plus 4.7 User guide need to be updated with
CrossReference Merge utility Tool. The FSIM Plus User guide
describes about How the Cross Reference utility operation
scenarios.
HIFS#334 cio_cp.exe crashes on FSIM load when the Save_all loaded are
misconfigured. When an AOUT block is configured to a device
having an ECB H/W Type 243 and S/W Type 23 without a
Child ECB configured with ECB Type 18,FSIM Engine fails to
load and cio_cp crashes

BI1#4226 Xref merge utility Crashing while pressing start button. Crashing
is happening in machines where excel is not installed.
Added condition for resolving this.

BI1#4227 Xref Merge utility - Timestamp not available in inside the Error
Log.txt. Created new class (LoggerFile) for log activity.
BI1#4229 Xref Merge utility - While clearing the XREF MERGED DATA
entry from DELETE button on a keyboard, the properties of the
help text changes.
Added new Thread function for resolving it.
Now when the text field becomes empty it is filled with default
text
BI1#4230 Xref Merge utility - Exception Error thrown while selecting
multiple Trisim engines. There is no condition check when user
tries to select Trisim engine name since the list is empty. It is
fixed by adding condition.
LFCR#4329 The documentation needs to be changed to clearly state that the
MDSCAN blocks are no longer supported. All references that
may imply support need to be removed.
LFCR#4383 FSIM Plus User Guide IACC Section Confusing.
Updated the section
15.6.1 Configuring the Co-Existence File and
15.6.2 Mapping the Plant CPs to the FSIM Stations
LFCR#4390 Documentation added for timing considerations for SimSync
Engine
Updated FSIM Plus User Guide Section 10.2
"SimSyncEngine Time Slice Behavior" with relevant

Page 12 of 15
RELEASE NOTES

Important: Read First

information

LFCR#4444 Documentation to explain that FAIM needs to be installed on all


AW hosts.
Updated the FSIM Plus User Guide Section 9.7 - Starting the
FAIM Processes
Updated the FSIM_Plus_Installation_Guide 12.1 - Installing the
FSIM Plus Software

LFCR#4483 Update the FSIM Plus User Guide to provide guidelines when
modifying the FSIM-CP mapping file for IEE.

Provide steps to update


Indicate what computers require a reboot
LFCR#4650 Changes in Foxboro.loc Cause FSIMAlmSnapMgr to not start.
Changed start_aw.cmd to validate the necessary services are
started first before launching FSIMAlmSnapMrg.

Summary of Enhancements in FSIM Plus 4.7 Software Release.

CR and feature Description

CBFS#692 Add option to FSIMEngine to turn off information messages to


GUI during Save and Restore snapshots
CBFS#338 Add I/A LoopID string to improve Bulk Configurator useability

Notable simulator migration issues in FSIM Plus 4.7 Software Release.

CR and feature Description

NIL NIL

Page 13 of 15
RELEASE NOTES

Important: Read First

Where to Find FSIM Plus Documentation


The FSIM Plus Installation, Getting Started, and User guides are available on the product installation
CD. When FSIM Plus software is installed, it will refresh the FSIM Plus guides installed with
DYNSIM software to match that of the current FSIM Plus version.

FSIM Plus and DYNSIM specific documentation can be accessed through a variety of means:

• Through the Graphical User Interface, from the Help pull down menu
• In PDF format where the software is installed and accessed from Start / Programs / SIMSCI /
DSS45 / Dynamic Simulation Suite / DSS Documentation
• From the IPS Global Product Support website:
o http://iom.invensys.com/EN/Pages/home.aspx under support tab

Additional SimSci-Esscor specific documentation and downloadable software is available at the


SimSci-Esscor Electronic Software Download website:
o http://www2.simsci.com/sim4me/esd/login.asp

Page 14 of 15
RELEASE NOTES

Important: Read First

License and Copyright Information

FSIM Plus Software The software described in this document is furnished under a written
4.7 Release Notes agreement and may be used only in accordance with the terms and
conditions of the license agreement under which you obtained it. The
technical documentation is being delivered to you AS IS and Invensys
Systems, Inc. makes no warranty as to its accuracy or use. Any use of the
technical documentation or the information contained therein is at the
risk of the user. Documentation may include technical or other
inaccuracies or typographical errors. Invensys Systems, Inc. reserves the
right to make changes without prior notice.

Copyright Notice © February 2011 Invensys Systems, Inc. All rights reserved. No part of
this publication protected by this copyright may be reproduced or utilized
in any form or by any means, electronic or mechanical, including
photocopying, recording, broadcasting, or by any information storage and
retrieval system, without the written permission from Invensys Systems,
Inc. A limited nonexclusive license to use the Software and
Documentation of CalHTMLPane v1.0b; Andrew Moulden of 82A
Queens Road, Leicester, United Kingdom is acknowledged.
Trademarks Invensys, ARPM, Avantis, Datacon, DYNSIM, Eurotherm,
Foxboro, FoxDraw, FoxView, FSIM Plus, HEXTRAN, I/A Series,
IMServ, InFusion, InPlant, Invensys Logo, PipePhase, PRO/II, ROMeo,
SIM4ME, Skelta, SimSci-Esscor, Triconex, TRISIM Plus, Wonderware
and Visual Flow are trademarks of Invensys plc, its subsidiaries and
affiliates. All other brand names may be trademarks of their respective
owners.

U.S. GOVERNMENT RESTRICTED RIGHTS LEGEND


The Software and accompanying written materials are provided with
restricted rights. Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights
in Technical Data And Computer Software clause at DFARS 252.227-
7013 or in subparagraphs (c) (1) and (2) of the Commercial Computer
Software-Restricted Rights clause at 48 C.F.R. 52.227-19, as applicable.
The Contractor/Manufacturer is: Invensys Systems, Inc. (Invensys
SIMSCI-ESSCOR) 26561 Rancho Parkway South, Suite 100, Lake
Forest, CA 92630, USA.

Printed in the United States of America January 2012.

Page 15 of 15

Potrebbero piacerti anche