Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Contents
Release Notes for FSIM Plus® Software Version 4.7 ...................................................... 1
Contents ...................................................................................................................... 1
Important Notices ............................................................................................................ 2
Installation Infrastructure Notice ................................................................................. 2
General Upgrade Notes................................................................................................ 2
Upgrade from prior FSIM Plus software versions ........................................................ 3
Patch Kit Installation Location Notice ......................................................................... 3
FSIM Plus Support for SOE and TDR / TDA .............................................................. 3
FAIM and AIM*® API Support .................................................................................. 3
Other Foxboro I/A Series Software Compatibility Notes: ............................................ 4
FSIM Plus 4.7 Software Compatibility ........................................................................ 4
Windows® OS Security Information ........................................................................... 6
Hardware Requirements for PC ................................................................................... 6
Single-Box Configuration ............................................................................................ 6
Multi-Box Configuration ............................................................................................. 6
Foxboro Control Software (FCS) Support .................................................................... 7
Optional Graphical User Interface/Instructor Station PC .............................................. 8
I/A Series Supported Control Blocks supported by FSIM Plus 4.7 Software ................ 8
FSIM Plus 4.7 Software Installation .............................................................................. 10
Pre-Install Checklist .................................................................................................. 10
Summary of New Features in FSIM Plus 4.7 Software Release ..................................... 11
Summary of Defects Resolved in FSIM Plus 4.7 Software Release. ............................... 11
Summary of Enhancements in FSIM Plus 4.7 Software Release. ................................... 13
Notable simulator migration issues FSIM Plus 4.7 Software Release. ............................ 13
Where to Find FSIM Plus Documentation ..................................................................... 14
License and Copyright Information ............................................................................... 15
1
RELEASE NOTES
Important Notices
FSIM Plus software version 4.7 works only with I/A Series™ 8.7 legacy security,
FoxView™ / FoxDraw™ (FV/FD) 10.2.3, and DYNSIM® 4.5(.x) versions. The FSIM
Plus software version 4.7 operation under the I/A Series 8.7 Cyber Secure environment is
under review as a possible future FSIM Plus software feature. For simulation with earlier
DYNSIM software versions or earlier I/A Series software releases refer to the
compatibility table in the body of this document. Consult compatibility table updates for
future software versions through technical support to determine future version DYNSIM
software and TRISIM Plus® software compatibility with FSIM Plus software.
There are two options available to prepare an I/A Series 8.7 system for FSIM Plus 4.7
software installation beginning with DYNSIM version 4.5 software.
1 - In a multi-host simulator system, you may use the Activation Manager 1.0 installer on
selected host machines when only FSIM, SimSync, or TRISIM engines will be installed
on that host. When this option is used, the DYNSIM engines and DYNSIM software User
Interface will NOT be installed. You may later add version compatible DYNSIM
infrastructure and DYNSIM engines if you choose. Note that a full DYNSIM
infrastructure install must be on at least one host machine in the simulator to provide a
simulator SQL data base host and Naming Service. The full DYNSIM software installer
is the only means of installing the SQL data base host, Dynamic Simulation Suite (DSS)
Naming Services, DYNSIM User Interface and DYNSIM engines.
2 – As in prior versions, you may install DYNSIM software 4.5.x with the FSIM
Plus/TRISIM Plus software installation option as a prerequisite to installing FSIM Plus
software. This option will install the DYNSIM User Interface with menus specific to
FSIM Plus in the DYNSIM user interface as well as all Dynamic Simulation System
components including fully functional Activation Manager 1.0 components. If you use
this option you do NOT need to separately install Activation Manager 1.0.
You may install FSIM Plus 4.7 software, DYNSIM 4.5(.x) software, and Activation
Manager 1.0 in any order but I/A Series 8.7 software must be installed first. Note that
installing both DYNSIM 4.5(.x) software and Activation Manager 1.0 is redundant
though harmless.
2
RELEASE NOTES
Snapshots saved in versions before FSIM Plus v4.7 software cannot be upgraded.
If using a TRISIM engine with FSIM Plus software, the Triconex SOE is not supported.
FSIM Plus software does not support Transient Data Recorder / Transient Data Analyzer
(TDR / TDA).
FAIM does not provide a complete implementation of AIM*API and will not support
AIM* client applications such as AIM*Explorer, AIM*DataLink and the AIM*Historian
tools such as the historian configurator, etc.
Users requiring AIM* client applications in a simulation environment should use the
actual AIM* Historian and its associated applications. In this instance, management of
trend and alarms for snapshots and time synchronization with the simulation cannot be
supported.
3
RELEASE NOTES
Note: It is not possible to have FAIM and AIM*Historian running on the same
workstation at the same time.
4
RELEASE NOTES
Notes
1 FSIM on Solaris I/A environment is no longer actively supported.
2 ISCM Not Configurable with I/A 8.4.3+.
3 FVFD V10.2.1 release will function without simulation support for Trends and Alarms.
4 I/A 8.5(+) / FSIM Plus 4.5(+) require an updated OS specific to I/A Series V8.5 Security Enhancements.
®
5 Dynsim V4.5.3 and TRISIM Plus 2.1 function with Windows 7 32-bit emulation mode.
6 InFusion 3.1 onwards is known as Foxboro Control Software (Applies to InFusionSIM also).
7 DYNSIM 4.5.5 with customization required
5
RELEASE NOTES
http://support.ips.invensys.com
Multi-Box Configuration
For a multi-box configuration, at least two computers are needed: the AW and the FSIM Plus computer.
Both computers must be model P90, P91, or P92, purchased from www.BuyAutomation.com. The
Page 6 of 15
RELEASE NOTES
AW requires the I/A Series 8.7 software to be purchased with the hardware. The FSIM Plus machine
requires only the P90, P91, or P92 computer, but must be installed with the I/A software prior to
installing FSIM Plus. The FSIM Plus computer can be installed using the AW software purchased
with the AW. Additional licensing is not required, unless the FSIM Station is used as an AW to view
FoxView or additional Detail Displays.
Note: The FSIM Plus 4.7 software must be installed on the AW computer.
Invensys provides a number of example FCS configurations that adhere to the above operational
recommendations in the Foxboro Control Software Deployment Guide, B0750BA.
Note that while the example configurations show FCS running on a different workstation than the
operator workstation running either Wonderware InTouch software or FoxView software, it is possible
to run them on the same workstation.
Note: Invensys does NOT support a single box setup for an FCS platform. For non-FCS I/A
Series configurators, FSIM Plus simulators with less than 6 CPs, single box configurations
have been used with limitations in performance.
Page 7 of 15
RELEASE NOTES
I/A Series Supported Control Blocks supported by FSIM Plus 4.7 Software
FSIM Plus supports a variety of platform specific blocks, including blocks/ECBs. Additional details
are listed in the FSIM Plus User Guide. In general, these platforms are supported by FSIM Plus:
• CP270
• CP60
• CP40
• CP30
• CP10
• Modbus
• Tricon
For FSIM Plus 4.7, the following features are supported for compatibility with I/A Series 8.7.
1. 100 to 200 Series FBM migration blocks for simulation compatibility with I/A Series 8.7.
2. Universal FBM Blocks for simulation compatibility with I/A Series 8.7.
3. Controls block algorithms modified by I/A Series 8.7 supported for simulation compatibility.
Refer to I/A Series 8.7 Release Notes and Software Installation Guide, section 2.6 Additions
and Changes to Control Block and Parameter Software and Documentation (B0700SE).
I/A Series 8.2 through 8.7 AW has limited capability to display some blocks and ECBs using FoxView
10.2.3, including:
• Micro I/A
• ECB 15, 16, 20, 40, and 85 – 100
• ABScan
Page 8 of 15
RELEASE NOTES
• Allen-Bradley Station
• PIDFF
• UNIVFF
Page 9 of 15
RELEASE NOTES
Pre-Install Checklist
This section lists the most common obstacles encountered by users when installing FSIM Plus. Before
you begin a new FSIM Plus install:
1. FSIM Plus software does not support having multiple versions of FSIM Plus installed
on the same machine.
2. FSIM Plus software (Dynamic Simulation Suite) does NOT support 64 bit operating
systems, Windows XP Home Edition, XP Starter Edition, ME, and Windows 98.
FSIM Plus 4.7 software must run on an I/A P90, P91, or P92 purchased from the
BuyAutomation and pre-installed with I/A partitioning and I/A users.
3. I/A Series 8.5 and 8.7 software must be installed before installing FSIM Plus 4.7
software, Activation Manager 1.0 or DYNSIM 4.5 software.
4. DYNSIM 4.5 software and/or Activation Manager 1.0 may be installed prior to, or after,
installing FSIM Plus 4.7 software. If installing DYNSIM, select the DYNSIM installer
option FSIM Plus/TRISIM Plus Core infrastructure installation option to create the
FSIM menu items in the DYNSIM user interface.
5. FSIM Plus software install testing has been performed only on I/A released operating
system media.
Microsoft Windows XP PRO SP3 – US English
Microsoft Windows Server 2003 SP2 – US English
Operating systems not explicitly tested are currently not supported.
6. Machine names should only include characters (A to Z) and (0 to 9). The machine
name must be six digits, all capital letters (i.e., ESS123).
7. If you have a firewall installed, it may interfere with the DSS Activation Service
Manager. You will need to put the firewall in "learning mode" the first time you start
up FSIM Plus or allow it to start various FSIM Plus processes with dynamic port
addresses. Note: Windows XP and Server 2003 include a Firewall/Internet Connection
Sharing (ICS) service that will interfere with the FSIM Plus services.
8. Data Execution Prevention may cause DYNSIM services and installer to be unreliable.
The options may be controlled from System Properties (right click on my computer)
Select: Advanced Tab -> Performance Options->Settings->Data Execution Prevention
Tab. The options are:
Page 10 of 15
RELEASE NOTES
“Turn on DEP for all programs and services except those I select” (Windows
2003 default)
“Turn on DEP for essential Windows programs and services only” (Windows
XP default)
We recommend using the option “Turn on DEP for essential Windows programs and
services only”. Additional information may be found on Microsoft Knowledge Base
Article 875352.
the AW. Since the user faces” ICC cannot open the FSIM
stations issue”, the Documentation the FSIM Plus installation
Guide section 7.10.2 Step 2 is updated to follow the
Workaround.
HIFS#333 FSIM Plus 4.7 User guide need to be updated with
CrossReference Merge utility Tool. The FSIM Plus User guide
describes about How the Cross Reference utility operation
scenarios.
HIFS#334 cio_cp.exe crashes on FSIM load when the Save_all loaded are
misconfigured. When an AOUT block is configured to a device
having an ECB H/W Type 243 and S/W Type 23 without a
Child ECB configured with ECB Type 18,FSIM Engine fails to
load and cio_cp crashes
BI1#4226 Xref merge utility Crashing while pressing start button. Crashing
is happening in machines where excel is not installed.
Added condition for resolving this.
BI1#4227 Xref Merge utility - Timestamp not available in inside the Error
Log.txt. Created new class (LoggerFile) for log activity.
BI1#4229 Xref Merge utility - While clearing the XREF MERGED DATA
entry from DELETE button on a keyboard, the properties of the
help text changes.
Added new Thread function for resolving it.
Now when the text field becomes empty it is filled with default
text
BI1#4230 Xref Merge utility - Exception Error thrown while selecting
multiple Trisim engines. There is no condition check when user
tries to select Trisim engine name since the list is empty. It is
fixed by adding condition.
LFCR#4329 The documentation needs to be changed to clearly state that the
MDSCAN blocks are no longer supported. All references that
may imply support need to be removed.
LFCR#4383 FSIM Plus User Guide IACC Section Confusing.
Updated the section
15.6.1 Configuring the Co-Existence File and
15.6.2 Mapping the Plant CPs to the FSIM Stations
LFCR#4390 Documentation added for timing considerations for SimSync
Engine
Updated FSIM Plus User Guide Section 10.2
"SimSyncEngine Time Slice Behavior" with relevant
Page 12 of 15
RELEASE NOTES
information
LFCR#4483 Update the FSIM Plus User Guide to provide guidelines when
modifying the FSIM-CP mapping file for IEE.
NIL NIL
Page 13 of 15
RELEASE NOTES
FSIM Plus and DYNSIM specific documentation can be accessed through a variety of means:
• Through the Graphical User Interface, from the Help pull down menu
• In PDF format where the software is installed and accessed from Start / Programs / SIMSCI /
DSS45 / Dynamic Simulation Suite / DSS Documentation
• From the IPS Global Product Support website:
o http://iom.invensys.com/EN/Pages/home.aspx under support tab
Page 14 of 15
RELEASE NOTES
FSIM Plus Software The software described in this document is furnished under a written
4.7 Release Notes agreement and may be used only in accordance with the terms and
conditions of the license agreement under which you obtained it. The
technical documentation is being delivered to you AS IS and Invensys
Systems, Inc. makes no warranty as to its accuracy or use. Any use of the
technical documentation or the information contained therein is at the
risk of the user. Documentation may include technical or other
inaccuracies or typographical errors. Invensys Systems, Inc. reserves the
right to make changes without prior notice.
Copyright Notice © February 2011 Invensys Systems, Inc. All rights reserved. No part of
this publication protected by this copyright may be reproduced or utilized
in any form or by any means, electronic or mechanical, including
photocopying, recording, broadcasting, or by any information storage and
retrieval system, without the written permission from Invensys Systems,
Inc. A limited nonexclusive license to use the Software and
Documentation of CalHTMLPane v1.0b; Andrew Moulden of 82A
Queens Road, Leicester, United Kingdom is acknowledged.
Trademarks Invensys, ARPM, Avantis, Datacon, DYNSIM, Eurotherm,
Foxboro, FoxDraw, FoxView, FSIM Plus, HEXTRAN, I/A Series,
IMServ, InFusion, InPlant, Invensys Logo, PipePhase, PRO/II, ROMeo,
SIM4ME, Skelta, SimSci-Esscor, Triconex, TRISIM Plus, Wonderware
and Visual Flow are trademarks of Invensys plc, its subsidiaries and
affiliates. All other brand names may be trademarks of their respective
owners.
Page 15 of 15