Sei sulla pagina 1di 31

DESCARGAS MAXIMAS EXTREMAS (m3/s) 250.

0
AÑO PUENTE SANCHEZ CERRO PUEN
1926 227.0 200.0
1927 181.0
1928 153.0 150.0
1929 113.0
1930 93.0 100.0
1931 85.0
1932 81.0 50.0
1933 65.0
1934 56.0 0.0
1935 54.0
1936 41.0 26 27 28 29 30 3
19 19 19 19 19 19
1937 38.0
1938 35.0
1939 31.0
1940 31.0
PUENTE SANCHEZ CERRO

7 28 29 30 31 32 33 34 35 36 37 38 39 40
92 19 19 19 19 19 19 19 19 19 19 19 19 19
DESCARGAS MAXIMAS EXTREMAS (m3/s)
AÑO Q Q ORDENADOS F(x) f(x)
1926 227.0 227.0 0.9913 0.000398
1927 181.0 181.0 0.9456 0.001854
1928 153.0 153.0 0.8714 0.003530
1929 113.0 113.0 0.6775 0.006031
1930 93.0 93.0 0.5495 0.006655
0.008000
1931 85.0 85.0 0.4960 0.006706
1932 81.0 81.0 0.4692 0.006686 0.007000
1933 65.0 65.0 0.3646 0.006316
0.006000
1934 56.0 56.0 0.3094 0.005925
1935 54.0 54.0 0.2976 0.005824 0.005000
1936 41.0 41.0 0.2267 0.005063
0.004000
1937 38.0 38.0 0.2118 0.004869
1938 35.0 35.0 0.1975 0.004671 0.003000
1939 31.0 31.0 0.1793 0.004401 0.002000
1940 31.0 31.0 0.1793 0.004401
0.001000

-
0.0 50.
MEDIA 85.60
DESV.EST. 59.49

histograma
0.008000

0.007000

0.006000

0.005000

0.004000

0.003000

0.002000

0.001000

-
0.0 50.0 100.0 150.0 200.0 250.0
ANALISIS CON DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS
AÑO Q Q ORDENADOS y = ln (x) F(x) f(x)
1926 227.0 227.0 5.4250 0.9656 0.1177
1927 181.0 181.0 5.1985 0.9292 0.2093
1928 153.0 153.0 5.0304 0.8869 0.2965
1929 113.0 113.0 4.7274 0.7709 0.4685
1930 93.0 93.0 4.5326 0.6703 0.5598
1931 85.0 85.0 4.4427 0.6185 0.5894
1932 81.0 81.0 4.3944 0.5898 0.6011
1933 65.0 65.0 4.1744 0.4549 0.6129
1934 56.0 56.0 4.0254 0.3656 0.5815
1935 54.0 54.0 3.9890 0.3446 0.5694
1936 41.0 41.0 3.7136 0.2045 0.4386
1937 38.0 38.0 3.6376 0.1728 0.3954
1938 35.0 35.0 3.5553 0.1422 0.3478
1939 31.0 31.0 3.4340 0.1042 0.2796
1940 31.0 31.0 3.4340 0.1042 0.2796

histograma de los x

0.7000

0.6000

0.5000

0.4000

0.3000

0.2000

0.1000

-
0.0 50.0 100.0 150.0 200.0 250.0
x (Caudales)
MEDIA 4.2476
DESV.EST. 0.6468

C.ASIMETRIA 0.3956

250.0
ANALISIS CON DISTRIBUCION LOG - NORMAL DE 3 PARAMETROS
AÑO Q Q ORDENADOS y = ln (x-a) F(x) f(x)
1926 227.0 227.0 5.31807 0.94064 0.11200
1927 181.0 181.0 5.06253 0.90623 0.15872
1928 153.0 153.0 4.86746 0.87138 0.19910
1929 113.0 113.0 4.49970 0.78355 0.27812
1930 93.0 93.0 4.24835 0.70745 0.32588
1931 85.0 85.0 4.12697 0.66671 0.34473
1932 81.0 81.0 4.06027 0.64342 0.35354
1933 65.0 65.0 3.73743 0.52452 0.37754
1934 56.0 56.0 3.49620 0.43360 0.37300
1935 54.0 54.0 3.43366 0.41041 0.36868
1936 41.0 41.0 2.88982 0.22900 0.28720
1937 38.0 38.0 2.70738 0.18006 0.24885
1938 35.0 35.0 2.48407 0.12990 0.20047
1939 31.0 31.0 2.07819 0.06531 0.12066
1940 31.0 31.0 2.07819 0.06531 0.12066

Si quiero conocer el caudal para Tr = 50.0 años

sabiendo que Tr = 1 / P exc

--> Pexc = 1 / 100 = 0.02


--> Pno exc = 1-P exc = 0.98

z = f ( Pexc) =DISTR.NORM.ESTAND.INV(1-Pexc)

z = 2.053749

y=m+z s

y= 5.8386
y = ln (x - a)

x-a= e (y)

x - a = 343.3057

x= 366.32
LN3; C.A.=0
0.40000
0.35000
0.30000
0.25000
0.20000
0.15000
0.10000
0.05000
-
1.50000 2.00000 2.50000 3.00000 3.50000 4.00000 4.50000 5.00000 5.50000 6.00000

MEDIA 3.6726
DESV.EST. 1.0547
a 23.0100

C.ASIMETRIA -1.00E-01

Si quiero conocer el caudal para Tr = 20.0 años

sabiendo que Tr = 1 / P exc

--> Pexc = 1 / 100 = 0.05


--> Pno exc = 1-P exc = 0.95

z = f ( Pexc) =DISTR.NORM.ESTAND.INV(1-Pexc)

z = 1.6448536

y=m+z s

y= 5.4074
y = ln (x - a)

x-a= e (y)

x - a = 223.04279

x= 246.05
ANALISIS CON DISTRIBUCION GUMBEL
Var. Reducida
AÑO Q Q ORDENADOS y = (x - u)/a Tr
1926 227.0 227.0 2.94 19.40
1927 181.0 181.0 2.15 9.09
1928 153.0 153.0 1.67 5.82
1929 113.0 113.0 0.98 3.20
1930 93.0 93.0 0.64 2.44
1931 85.0 85.0 0.50 2.20
1932 81.0 81.0 0.43 2.10
1933 65.0 65.0 0.16 1.74
1934 56.0 56.0 0.00 1.59
1935 54.0 54.0 (0.03) 1.56
1936 41.0 41.0 (0.25) 1.38
1937 38.0 38.0 (0.30) 1.35
1938 35.0 35.0 (0.36) 1.32
1939 31.0 31.0 (0.42) 1.28
1940 31.0 31.0 (0.42) 1.28

x medio 85.60 0.5128


desv. Est x (Sx) 59.49 1.0206

n = número de datos 15
yn medio = 0.5128
Sn = 1.0206

parámetros, según n
a = Sx / Sn = 58.29
u = x-yn*a= 55.71
250.0
f(x) = 72.6615664833 ln(x) + 20.8604404093
Q (m3/s))

R² = 0.9899071369
200.0

150.0

100.0

50.0

0.0
1.00 10.00 100.00
Tr (AÑOS)

e  y 1 x−u
F (x  X )  1 e  y=
Tr a
Si quiero conocer el caudal para Tr = 50

sabiendo que:

1 - e(-e(-y))= 0.02

e(-e(-y))= 0.98

-e(-y)= -0.0202027

e(-y)= 0.0202027

-y = -3.9019387

y = 3.9019387

y= x-u
a

x= u + a.y

x= 283.1
100.00
VALORES GUMBEL

Media reducida Yn

n 0 1 2 3 4 5 6 7 8 9
10 0.4952 0.4996 0.5035 0.5070 0.5100 0.5128 0.5157 0.5181 0.5202 0.5220
20 0.5230 0.5252 0.5268 0.5283 0.5296 0.5309 0.5320 0.5332 0.5343 0.5353
30 0.5362 0.5371 0.5380 0.5388 0.5396 0.5402 0.5410 0.5418 0.5424 0.5430
40 0.5436 0.5442 0.5448 0.5453 0.5458 0.5463 0.5468 0.5473 0.5477 0.5481
50 0.5485 0.5489 0.5493 0.5497 0.5501 0.5504 0.5508 0.5511 0.5515 0.5518
60 0.5521 0.5524 0.5527 0.5530 0.5533 0.5535 0.5538 0.5540 0.5543 0.5545
70 0.5548 0.5550 0.5552 0.5555 0.5557 0.5559 0.5561 0.5563 0.5565 0.5567
80 0.5569 0.5570 0.5572 0.5574 0.5576 0.5578 0.5580 0.5581 0.5583 0.5585
90 0.5586 0.5587 0.5589 0.5591 0.5592 0.5593 0.5595 0.5596 0.5598 0.5599
100 0.5600

Desviación tipica reducida Sn

n 0 1 2 3 4 5 6 7 8 9
10 0.9496 0.9676 0.9833 0.9971 1.0095 1.0206 1.0316 1.0411 1.0493 1.0565
20 1.0628 1.0696 1.0754 1.0811 1.0864 1.0915 1.0961 1.1004 1.1047 1.1086
30 1.1124 1.1159 1.1193 1.2260 1.1255 1.1285 1.1313 1.1339 1.1363 1.3880
40 1.1413 1.1430 1.1458 1.1480 1.1499 1.1519 1.1538 1.1557 1.1574 1.1590
50 1.1607 1.1623 1.1638 1.1658 1.1667 1.1681 1.1696 1.1708 1.1721 1.1734
60 1.1747 1.1759 1.1770 1.1782 1.1793 1.1803 1.1814 1.1824 1.1834 1.1844
70 1.1854 1.1863 1.1873 1.1881 1.1890 1.1898 1.1906 1.1915 1.1923 1.1930
80 1.1938 1.1945 1.1953 1.1959 1.1967 1.1973 1.1980 1.1987 1.1994 1.2001
90 1.2007 1.2013 1.2020 1.2026 1.2032 1.2038 1.2044 1.2049 1.2055 1.2060
100 1.2065
Probabilidad de excedencia F(x) Diferencia Delta D
DATOS Empírica Normal LN2 LN3 Gumbel Normal LN2 LN3
1 4424.0 0.063 0.009 0.034 0.059 0.052 0.05377 0.02815 0.00314
2 3200.0 0.125 0.054 0.071 0.094 0.110 0.07061 0.05425 0.03123
3 3107.0 0.188 0.129 0.113 0.129 0.172 0.05890 0.07443 0.05888
4 2500.0 0.250 0.323 0.229 0.216 0.312 0.07254 0.02090 0.03355
5 2250.0 0.313 0.451 0.330 0.293 0.410 0.13800 0.01724 0.01995
6 2220.0 0.375 0.504 0.381 0.333 0.454 0.12902 0.00649 0.04171
7 2200.0 0.438 0.531 0.410 0.357 0.477 0.09332 0.02730 0.08092
8 1900.0 0.500 0.635 0.545 0.475 0.574 0.13544 0.04507 0.02452
9 1793.0 0.563 0.691 0.634 0.566 0.630 0.12811 0.07194 0.00390
10 1700.0 0.625 0.702 0.655 0.590 0.643 0.07736 0.03038 0.03541
11 1616.0 0.688 0.773 0.796 0.771 0.724 0.08580 0.10801 0.08350
12 1530.0 0.750 0.788 0.827 0.820 0.742 0.03820 0.07721 0.06994
13 1525.0 0.813 0.803 0.858 0.870 0.760 0.00999 0.04527 0.05760
14 1108.0 0.875 0.821 0.896 0.935 0.783 0.05435 0.02080 0.05969
15 1042.0 0.938 0.821 0.896 0.935 0.783 0.11685 0.04170 0.00281

0.13800 0.10801 0.08350


Aceptada Aceptada Aceptada
0.3512
cia Delta D
Gumbel
0.01095
0.01500
0.01578
0.06218
0.09737
0.07893
0.03940
0.07373
0.06780
0.01792
0.03643
0.00793
0.05261
0.09197
0.15447

0.15447
Aceptda
3512
DISEÑO DE BARRAJE
Caudal de diseño: Qmax. Avenida: 366.32 m3/s

Calculo del caudal de captacion


Qmedia: 6 m3/s
Qminimo 3 m3/s

NMA

ALTURA DEL ALIVIADERO O BARRAJE FIJO

Qdiseño: 366.32 m3/s


L: 120 m
n: 0.042
S: 0.0013
H:

Adoptamos una seccion rectangular:

H: 1.80

L: 120

DIMENSIONAMIENTO DE LA COMPUERTA DE LIMPIA O BARRAJE MOVIL


barraje fijo barraje movil

1.80 A A1
2
L-b b

A1=A2/10 11A1=At
A1+A2=At A1= At/11
A1= 19.64
b=A1/h= 10.91

Longitud de cada compuerta:


L=b/4= 2.73 asumimos L= 2.7 4 compuertas

Predimensionamos el espesor de un pilar

e=L/4= 0.7
104.3

10.8 m 109.2 m

DISEÑO DEL BARRAJE FIJO

P= altura del barraje o aliviadero ha HO


Ho=carga de diseño Hc
Hc=altura de agua antes del remanso de presion
ha= carga de velocidad 0.2Ho
0.5Ho
P= 1.80
1
1.5 0.5Ho

L= l+2(NKp+Ka)He = 109.2 ps
Donde:
L= longitud efectiva de la cresta
l= longitud neta de la cr 109.20 ps
N= numero de pilas = 0 (por que la luz entre los claros no debe exceder en 20 ps)
Kp= coeficiente de contraccion de las pilas= 0.01
Ka= coefic. de contraccion de los estribos= 0
He= carga total de la cresta= 1.00 ps

Ho He/Ho He C/Co P/Ho Co C (hd+d)/He


1.8 1 1.8 1 1 3.84 3.84 2
1.5 1 1.5 1 1.2 3.85 3.85 2.2
1 1 1 1 1.8 3.94 3.94 2.8
0.5 1 0.5 1 3.6 3.95 3.95 4.6
0.2 1 0.2 1 9.0 4 4 10
0.73 1 0.73 1 2.5 3.94 3.94 3.47

DESCARGA DE LA COMPUERTA DE LIMPIA

Ho= 1.80
P= 0

L= l+2(NKp+Ka)He
Donde:
L= longitud efectiva de la cresta
l= longitud neta de la cr ps 10.8
N= numero de pilas = 3 (por que la luz entre los claros no debe exceder en 20 ps)
Kp= coeficiente de contraccion de las pilas= 0.01 tajamar redondo
Ka= coefic. de contraccion de los estribos= 0.2
He= carga total de la cresta= 4.00 ps

Ho 2Ho He/Ho He C/Co P/Ho Co C


1.8 3.6 1 3.6 1 0 3.087 3.087
1.5 3 1 3 1 0 3.087 3.087
1 2 1 2 1 0 3.087 3.087
0.5 1 1 1 1 0 3.087 3.087
0.2 0.4 1 0.4 1 0 3.087 3.087

Ho Q1 Q2 QT
1.8 620.49 43.24 663.73
1.5 550.91 37.44 588.35 Ho= 0.73 m.
1 430.25 27.50 457.74
0.5 271.73 16.64 288.37 Qt= 366.32 m3/s
0.2 149.38 8.81 158.20

Ho= 0.73

P= 1.80

d2
d1

Según la formula de Bernoulli tenemos:

P+Ho+Vo2/2g = d1+V12/2g+hf

q=Q/L= 3.19 m3/s

Vo=q/Ho= 4.38 m/s


Vo /2g=
2
0.98 m
q2/2g= 0.52
3.51 d1+0.52/d12
d1= 0.41 tomamos diferentes valores
3.51 3.51

calculo del tirante conjugado d2


d2=-d1/2+(d12/4+2*(V12/g)*d1)1/2

V1=q1/d1= 7.79 m/s


d2= 2.06 m

Calculo de la longitud del colchon disipador

1. - L = (5 a 6)*(d2-d1) = 9.89 m.
2. - L=d1*F1 = 9.56 m
F1=V1/(g*d1)1/2 = 3.89
3. - 4d2 = 8.23 m.
por lo tanto: d2 = 9.89 m.

Encontrar los siguientes valores:

Xc=0.284*Ho= 0.21 m.
Yc=0.127*Ho= 0.09 m.
R1=0.5*Ho= 0.37 m.
R2=0.2*Ho= 0.15 m.

PREDIMENSIONAMOS EL BARRAJE

x= 2.7 Lp=

Ho= 0.73 0.21


0.09

0.15
0.37
P= 1.80

0.37

0.35 0.41
0.9
1.50 2.35
0.69
0.8 11.09

CALCULO DEL ESPESOR DE LA POZA AMORTIGUADORA

e=4/3*(H*ɤa-H2*ɤa)/ɤc= 0.67 m.
ɤc= 2400 kg/m3
ɤa= 1000 kg/m3
H=h+h1-h/L*X= 3.26

h= 0.47 m
h1= 2.96 m
X= 3.24 m
L= 9.12 m
h/L= 0.052

CONTROL DE LA FILTRACION
L= 9.12 camino de la percolacion
C= 12 coef. Bligh para areana fina
h= 0.47 m
C*h= 5.7
L≥ C*h
9.12 ≥ 5.7

DISEÑO ESTRUCTURAL
3.36

10.8 109.2
Ho He/Ho He C/Co P/Ho

Cs/C Cs L Q=Cs*LHo3/2
1 3.84 109.20 620.49
1 3.85 109.20 550.91
1 3.94 109.20 430.25
1 3.95 109.20 271.73
1 4 109.20 149.38
1 3.94 109.20 348.82
(hd+d)/H Cs/C Cs L Q=Cs*LHo3/2
1 0.76 2.3461 12.46 43.24
1 0.76 2.3461 12.18 37.44
1 0.76 2.3461 11.72 27.50
1 0.76 2.3461 11.26 16.64
1 0.76 2.3461 10.98 8.81
9.89

H2= 2.06

2.00
0.69

0.35 0.8

60°
Co C (hd+d)/He Cs/C Cs q=CsHe3/2 He+P Va=q/(He+P)
60°
Perd. Fricc. Perd. Entrada total Carga Q=
ho=V2 /2g S hf=S*L 0.1ho perd. bruta Cs*LHo3/2
La capacidad de la toma se determina de acuerdo a la demanda de la cedula de cultivos en caso
de un proyecto agricola, o de acuerdo a las capacidades de la central hidroelectica o del proyec-
de abastecimiento de agua potable considerando adicionalmente la sperdidadas necesarias para
eliminar los sedimentos que pudieran ingresar.
Q= 6 m3/s
calcularemos los caudales de captacion como vertederos:
Q= CLh3/2
Donde:
Q= caudal a derivar mas caudal necesario para el sistema de purga
C= coeficiente de vertedero, en este caso = 1.84
L= longitud de la ventana que por lo general se asume entre 3 y 4m.

4 m
h=(Q/(CL)) =
2/3
0.87
asumimos h= 1.00 m

H= 1.80 m. Altura total del barraje vertedero


0.2

ho (min:60cm)= 0.6