Sei sulla pagina 1di 1

10

15 130x6 FL KICKPLATE 100x6 FL KICKPLATE TUBO O PLANCHA DE 6 50 GAP DE 10


GAP DE 10
ARREGLO DE 10 GAP DE 10 GAP DE 10 10 GAP 6 PLATE OR PIPE TYP 10 GAP BARRA CUADRADA

10 MAX.
CADA 4 BARRAS DE 25 GAP DE 10 GAP DE 10
EVERY 4TH LOAD BAR PARRILLA - 10 GAP 10 GAP 30 MIN
5 25 SQ. BAR 10 GAP 10 GAP
GRATING FIXING
UNIR BARRA 32x5 EN EXTREMOS 5 50-350

100
6
DIRECTION OF LOAD BARS 32x5 BAND BAR TO EDGES 6 6

100
5 50-350 5 50-250 5 50-350
1 5 50-250

EX EA10 x 50 DE LONGITUD 50
CARA DE CADA 2000 VIGA O CANAL MIN 50x10 PL. FLANGE EXTENSION PLATE CADA BARRA EA5
300 MAX. CANTILEVER 15 10 PL. FLANGE EXTENSION PLATE 75 400 MAX
EX EA10 x 50 LONG AT 2000
ESTRUCTURA
MAX. CRS.
BEAM OR CHANNEL
MAX
EVERY LOAD
BAR 5 ARREGLO DE 10 ARREGLO DE 10 ARREGLO DE 10 EA5
FACE OF
STRUCTURE
ARREGLO DE 10 PARRILLA PARRILLA PARRILLA
PARRILLA GRATING FIXING GRATING FIXING GRATING FIXING
-
GRATING FIXING
EN BORDE DE VIGA VIGA CANALES DIA. OR SQ. - 100 AND OVER. SMALLER SIZESTO
EN VOLADO BEAM CHANNELS FLOOR BEAM FLANGE EXTENSION PARRILLA PLANCHA DE PISO PARRILLA PLANCHA DE PISO PARRILLA PLANCHA DE PISO
AT EDGE BEAM BE SQUARE SITE CUT (NO KICK PLATE)
GRATING FLOOR PLATE GRATING FLOOR PLATE GRATING FLOOR PLATE
AT CANTILEVER REFERIRSE A NOTA 1 ABAGO NOTA:-
REFER TO NOTE 1 BELOW EMPALME DE PARRILLA EN VIGAS DE APOYO PASE DE TUBO EN PARRILLA DETALLES DE PARRILLA A LOSA DE PISO
CUANDO BARRAS DE SOPORTE DE PARRILLA TIENEN
SPLICE IN GRATING AT SUPPORT BEAMS UNA DISTANCIA ENTRE APOYOS MAYOR A 200mm GRATING PENETRATIONS AT PIPE GRATING TO FLOOR PLATE DETAILS
NOTE:-
DETALLE 1 DETALLES DE PARRILLA FLANGE EXTENSION PLATE IS REQUIRED DETALLE 2 DETALLE 3
DETAIL GRATING DETAILS WHERE GRATING LOAD BARS ARE UNSUPPORTED DETAIL DETAIL
FOR A LENGTH GREATER THAN 200mm

5 GAP DE 10 5 50-350 50 TYP TUBO O PLANCHA DE 6 1500 MAX CLEAR SPAN NOTA:-
50 10 GAP 400 MAX DIM 'A' 1.
6 PLATE OR PIPE
GAP DE 10 30 MIN
5 50-350 100x6 FL KICKPLATE 10 GAP 5 50-350 O ABERTURA SE PROYECTA A MENOS DE
100x6 LISO 40mm DE LA MIASA.
10 MAX

100x6 FL 2. PASES O ABERTURAS MENORES A 100mm


5 50-350

MIN
100
KICKPLATE 1

SUPPORT UNDER

SUPPORT UNDER
75

APOYO ABAJO

APOYO ABAJO
DIM 'B'
EX EA4 x 50 DE LONGITUD 3.
CARA DE CADA 2000 SELLADOR SIKAFLEX 75 LLENAR AGUJERO
ESTRUCTURA EX EA4 x 50 LONG AT 2000 MAX. ENTRE SOLDADURAS MAX CON SELLADOR
FACE OF CRS. VIGO O CANAL SIKAFLEX SEALANT SIKAFLEX NOTE:-
15 FILL HOLE WITH 400 MAX. 1. ALL PENETRATIONS OR CUTOUTS SHALL BE
STRUCTURE LLENAR AGUJERO CON BEAM OR CHANNEL BETWEEN WELDS
SELLADOR SIKAFLEX SIKAFLEX SEALANT TAKEN TO THE NEAREST LOAD BAR IF
FILL HOLE WITH PENETRATIONS OR CUTOUTS FALL WITHIN
200 MAX. CANTILEVER SIKAFLEX SEALANT NOTA:- 40mm OF A LOAD BAR.
ARREGIO EN VIGAS DIA. OR SQ. - 100 AND OVER. SMALLER SIZES 2. PENETRATIONS OR CUTOUTS LESS THAN
EN VOLADO EN BORDE DE VIGA JUNTA EN VIGAS TO BE SQUARE SITE CUT (NO KICK PLATE) 130 x 6 FL KICKPLATE 100mm TO BE FABRICATED SQUARE.
TODOS BORDES NO APOYADOS DE LA PLANCHA DE PISO. FIXING TO BEAMS CADA BARRA
AT CANTILEVER AT EDGE BEAM JOINT ALONG BEAMS NOTE:- 5 EVERY LOAD BAR 3. IF DIMENSION 'A' GREATER THAN 400 THEN
DIMENSION 'B'=650 MAX.
REFERIRSE A NOTA 1 ABAGO FLANGE EXTENSION PLATE IS REQUIRED AT
REFER TO NOTE 1 BELOW ALL UNSUPPORTED EDGES OF FLOOR PLATE.
CUANDO SE NECESITE.
PF3 TRIMMER (MAX SPAN 3000) TO BE ADDED AS
DETALLES DE PLANCHA DE PISO FLOOR BEAM FLANGE EXTENSION PASE DE TUGO EN PLANCHA DE PISO APOYO DE PARRILLAS IN ABERTURAS REQUIRED.

FLOOR PLATE DETAILS FLOOR PLATE PENETRATIONS AT PIPE GRATING SUPPORT AT OPENING
DETALLE 4 DETALLE 5 DETALLE 6
DETAIL DETAIL DETAIL

50
50
100x6 FL KICKPLATE CADA 4 BARRAS 100x6 FL KICKPLATE UNIR BARRA 32x5
CADA 4 BARRAS UNIR BARRA NOTA 1:- NOTE 1:-
UNIR BARRA 32x5 EN EXTREMOS EVERY 4TH LOAD 50 EN EXTREMOS DIM 'A' 32x5 EN ANGLE SUPPORT TO KICKPLATE WHERE
5 EVERY 4TH LOAD 5
32x5 BAND BAR TO EDGES BAR 32x5 BAND BAR TO BAR EXTREMOS CUANDO SEA NECESSARIO (SOLO CUANDO REQUIRED ( i.e. WHEN SUPPORT FROM
EDGES 32x5 BAND BAR NO SE PUEDE APOYAR EN POSTES O EN STANCHIONS OR COLUMNS IS NOT AVAILABLE).
TO EDGES COLUMNA). EXCEPTO CUANDO ESPACIO EXCEPT WHERE EQUIPMENT CLEARANCE IS
GAP DE 10 LIBRE DE EQUIPO ES MENOS DE 20mm. LESS THAN 20 mm. MAX. UNSUPPORTED SPAN
10 GAP FOR KICKPLATE 2400mm IN CONTINUOUS RUN
130 x 6 FL KICKPLATE OR 300mm AS CANTILEVER .
CONTINUO O 300mm SI ES EN VOLADO .
50

CARTELAS DE ARRIOSTRE
BRACING CLEAT PLATES NOTA :- NOTES:-
LISO 1. 1. REFER DRAWING S-001 FOR STANDARD
CADA 4 BARRAS 130 x 6 FL ACERO Y TABLAS DE ELEMENTOS EN PLANO S-001. STEELWORK NOTES AND MEMBER TABLE.
EVERY 4TH LOAD KICKPLATE 2. TODAS LAS BARANDAS DEBEN SER TUBULARES 2. ALL STAIR HANDRAILING SHALL BE TUBULAR
5 DIM 'A' HANDRAILING BY GRATING PERU SAC UNO.
BAR DE GRATING PERU SAC, SIC.
LISO 3. 3. STAIR TREADS TO BE GRP-06 MILD STEEL BY
CUANDO DIM 'A' SEA MAYOR QUE 100 COLOCAR
CUANDO DIM 'A' SEA MAYOR QUE 100 130 x 6 FL GRATING PERU SAC. GALVANISED TO ASTM
PARILLA DE RELLENO EN COLUMNA
COLOCAR PARRILLA DE RELLENO EN KICKPLATE A123 OR APPROVED EQUIVALENT.
WHEN DIM 'A' IS GREATER THAN 100 PROVIDE EQUIVALENTE APROBADO.
COLUMNA. 4. FLOOR PLATE TO BE 6mm THICK WITH RAISED
GRATING INFILL TO COLUMN 4.
WHEN DIM 'A' IS GREATER THAN 100 ANGULAR PATTERN UNO.
BARANDAS OMITIDAS POR CLARIDAD BARANDAS OMITIDAS POR CLARIDAD PROVIDE GRATING INFILL TO COLUMN.
HANDRAILS OMITTED FOR CLARITY HANDRAILS OMITTED FOR CLARITY RELIEVE SIC.

DETALLE DE PARRILLA EN COLUMNA DETALLE EN COLUMNA CON ARRIOSTRE VERTICAL DETALLE EN COLUMNA INTERNA
GRATING DETAIL AT COLUMN DETAIL AT COLUMN WITH VERT. BRACING DETAIL AT INTERNAL COLUMN APROBADOS PARA
DETALLE
DETAIL
7 DETALLE
DETAIL
8 DETALLE
DETAIL
9 CONSTRUCCION
Ausenco Solutions
COPYRIGHT c Ausenco Limited
Canada Inc.

855 Homer Street A1


Vancouver. BC
Canada V6B 2W2

T +1 778 374 6999


F +1 778 374 6998
W www.ausenco.com

2172

Potrebbero piacerti anche