Sei sulla pagina 1di 3
IR - INSPECTION REQUEST west umar-secrow es = | Contractor No.: AWQ0109 2KonMobil Project Title: Eco Produced Water Treatment M109 a vocarionsos [RNOFRNECECOIT | sue reo retary 2007 DAScPUNE: cv sumer: | wines INSPECTION REQUIRED DATEO7 Febwary 2017 | TME1-00 REF.SPECIFICATION: 1QWOQ-FT-NSPDS-00-040901 REV.1 EARTHWORK 1QWQ-CE1091-COFND-D6-0002 REV.1 FOUNDATION FOR PRE-SEPARATOR IQD6- ee ‘AB/681050 PLAN SECTION & DETAIL RFF ITP: : 1QWQ-CE1092-CPQAC-00-0001 REV. C CIVIL INSPECTION AND TEST PLAN (OTHERS REF.: PEPE ATTACHMENT /CHECK LIST IF ANY: NAME OF CONTRACTOR/SUBCONTRACTOR: (CPECC/AL MADAR ‘Our request the inspection of the following works for certificate/witness that ail items has been properly executed in accordance with approved procedures, specifications, drawings and all tems has been coordinated with future works. DDISCRIPTION OF WORK TO BE WITNESS: Before backfiling, we have scarified end rolled the top of the original layer under tank foundation in DSB, end have coordinated with AL- FAO laboratory to take samples to test Proctor Density for information. No loose soll on the top of the original layer. Request witness, ‘COMMENTS: ‘Biaccerren = Claccepreo wit comments [ i Clworkis nat ready Se Clunacceptable inspection result see comments | Cl tice tis Box iF “NO” EMIL / SOC and fits a “WITNESS” as por ITP, {by ticking this box means CPECC needs to produce all te related documents and sign / close this IR} SIGNATURE FOR NOTIFICATION/ ACKNOWLEGEMENT ‘SUBCONTRACTOR ‘COMPANY OTHERS PRINT NAME: PRINT NAME PRINT NAME Valid we beeof waned ge SATE 7 earn SIGNATURE? SIGNATURE hs MOE | pare: Z-2— DOW | oare: ofr} ORE) ype P| ATE ExonMobil Eco West Qurna | Form No. F70102Q Contract:AWQ0109 Rev. 0 Project Location: Basra, Iraq Serial No. QUALITY CHECKSHEET - FIELD COMPACTION TEST RECORD ‘Tag Description Tag No. DSE Contract No. Awioley ‘System No. Contractor CPE ‘Sub-System No. DS—- BI bz 1050 Drawing Reference Vawp-cxier/-Lophpk-o-2} | Location Psb-AsTlsie Jomedpon ‘Type Fill Subsraute Lik Thi ickness fy Vest Date 20N. DI S-cEoleg-Emil—o 008 Min, Compaction Required: Jo % Laboratory Standard Field Test Equip: 2 Type Compaction Date Jot].2all Max. Density _ G42 SYym3_ Optimum Moisture __ 15-2 Z, oe Want Type SIN Conestion Factor ean Se se [Pee | a [oy [oe [ie t 9 |eze| 97 2. ‘7 teges| 95 Comments ContrastoriConstruction Rep. Contractor Quality Rep. Company Rep. vine nolitwhesd|| sn Me Fane = Signature: Spee Z| sina Jt 7 ‘Signature: Die Tae 2077, 1. FP *PL/i* AL FAO COMPANY 2 hel Tel TaN cia oat cae eo 2 Se aati 3 ( iS Dee aw ow] Ran] Onto oN i] NO: 947 . Date: 11/02/2017 i Fao Code:738/17 To\China Petroleum Engineering & Construction Corporation Sub\ Test Report (Re-Compaction of Soil) Information requested test : No. @ Date of test request Area Location CE-C0027@ 05 -02-2017 CPECC/MADAR Test date : 09-01-2017 Result: Max dry density (gm /em’) Optimum moisture content (%) Notes: The test for M.D.D done according to(ASTM D 1557-002), and for soil test according to (1D2937-07). ~ The result represents sample tested only. The Sample brought and received by Mr.: ( i + Executive Manager Ahlam Almansor Sec mM. Abacc FP13-04 heeam ay Pagel3)(2

Potrebbero piacerti anche