DESIGN MIX

STANDARD DEVIATION OF COMPRESSIVE STRENGTH

1. STRENGTH REQUIREMENTS
S=4
fcr = fc’ + 1.34s =
fcr = fc’ + 2.33s – 3.45 =
fcr = fc’ + 0.825s =
fcr = fc’ + 25 =

2. Water-Cement ratio
w/c = 0.61

3. Coarse Aggregate requirements


19 mm (3/4 in)
Fineness Modulus = 2.6
CA Factor = 0.64
Dry Weight of CA = 0.64 x 1600 = 1024 kg/m³

4. Air Content
Non-air entrained = 2%

5. Workability
75 – 100mm

6. Water Content
Non-air entrained
Water = 201.714 kg/m³
Required water = 201.714 kg/m³

7. Cement Material Content


w/c = 0.61
Water = 201.714 kg/m³
Cement = Water/ (w/c) = 201.714/ 0.61 = 330.192 kg/m³

8. Fine Aggregate requirements


Water Volume = 201.714/ 1000 = 0.202
Cement Volume = 330.192/ 3.15(1000) = 0.1048
Air Volume = 0.02
Coarse Aggregate Volume = 1024/ 2.66(1000) = 0.3850
Subtotal Volume = 0.7118
Fine Aggregates Volume = 1 – 0.7118 = 0.2882

Dry Weight of FA = 0.2882 x 2.57 x 1000 = 740.674 kg/m³

9. Moisture Corrections
Coarse Aggregate = 1024 (1.0234) = 1044.48 kg/m³
Fine Aggregates = 740.674 (1.05) = 755.488 kg/m³
Water = 201.714 – 1024(0.0234-0.004) – 740.674(0.05-0.007) = 149.999 kg/m³

REQUIRED WATER = 201.714 kg/m³


REQUIRED CEMENT = 330.192 kg/m³
REQUIRED CA = 1024 kg/m³
REQUIRED FA = 740.674 kg/m³