Medium voltage products

VD4
Medium voltage vacuum circuit-breakers

www.nepsi.com
12...36 kV - 630...3150 A - 16...50 kA
Provided by Northeast Power Systems, Inc.
www.nepsi.com
Index

4 1. Description

1 2 2. Selection and ordering

6 4 3. Specific product characteristics

6 8 4. Overall dimensions

9 5 5. Electric circuit diagram

Provided by Northeast Power Systems, Inc.


www.nepsi.com

3
1. Description

The new VD4 are a synthesis of renowned technology Current interruption in vacuum
in designing and constructing vacuum interrupters The vacuum circuit-breaker does not require an interrupting
embedded in poles, and excellency in design, engineering and insulating medium. In fact, the interrupters do not contain
and production of circuit-breakers. ionisable material.
The VD4 medium voltage circuit-breakers use vacuum In any case, on separation of the contacts an electric arc
interrupters embedded in the poles. This construction is generated made up exclusively of melted and vaporised
technique makes the circuit-breaker poles particularly contact material.
sturdy and protects the interrupter from impacts, dust The electric arc remains supported by the external energy
deposits and humidity. The vacuum interrupter houses the until the current is cancelled in the vicinity of natural zero. At
contacts and makes up the interrupting chamber. that instant, the rapid reduction in the load density carried
and the rapid condensation of the metallic vapour, leads to
extremely rapid recovery of the dielectric characteristics.
The vacuum interrupter therefore recovers the insulating
capacity and the capacity to withstand the transient recovery

Provided by Northeast Power Systems, Inc.


voltage, definitively extinguishing the arc.
Since high dielectric strength can be reached in the vacuum,

www.nepsi.com
• Vacuum interruption technique
• Vacuum contacts protected against oxidation and
1 contamination
• Vacuum interrupter embedded in the pole
2 • Interrupter protected against shocks, dust and humidity
• Operation under different climatic conditions
3 • Limited switching energy
• Stored energy operating mechanism with anti-pumping
4
device supplied as standard
• Simple customisation with a complete range of
accessories
5 • Fixed and withdrawable version
6 • Compact dimensions
• Sealed-for-life poles
7 • Sturdiness and reliability
• Limited maintenance
• Circuit-breaker racking in and racking out with door
8
closed
9 • Incorrect and hazardous operations are prevented
thanks to special locks in the operating mechanism and
10
in the truck
• High environmental compatibility
1 Upper terminal 9 Pole fixing
2 Vacuum interrupter 10 Connection to operating
3 Housing/pole mechanism
4 Stem of moving contact
5 Lower terminal
6 Flexible connection
7 Tie-rod spring fork
8 Tie-rod

Vacuum interrupter embedded in the pole

4
even with minimum distances, interruption of the circuit is mechanism, with stored energy and free trip.
also guaranteed when separation of the contacts takes place These characteristics allow opening and closing operations
a few milliseconds before passage of the current through independent of the operator. The operating mechanism is of
natural zero. simple conception and use and can be customised with a
The special geometry of the contacts and the material used, wide range of accessories which are easy and rapid to install.
as well as the limited duration and low voltage of the arc, This simplicity converts into greater reliability of the apparatus.
guarantee minimum contact wear and long life. Furthermore,
the vacuum prevents their oxidation and contamination. The structure
The operating mechanism and the poles are fixed to a metal
Operating mechanism frame which is also the support for the fixed version of the
The low speed of the contacts, together with the reduced run circuit-breaker. The compact structure ensures sturdiness and
and low mass, limit the energy required for the operation and mechanical reliability.
therefore guarantee extremely limited wear of the system. Apart from the isolating contacts and the cord with plug for
The circuit-breaker therefore only requires limited connection of the auxiliary circuits, the withdrawable version

Provided by Northeast Power Systems, Inc.


maintenance. is completed with the truck for racking it into and out of the
The VD4 circuit-breakers use a mechanical operating switchgear or enclosure with the door closed.

www.nepsi.com

5
1. Description

Quenching principle of ABB interrupters At the rated current of the vacuum interrupter, the electric arc
is always of the diffuse type. Contact erosion is very limited
In a vacuum interrupter, the electric arc starts at the moment and the number of current interruptions very high.
of contact separation and is maintained until zero current and As the interrupted current value increases (above the rated
can be influenced by magnetic fields. value), the electric arc tends to be transformed from the
diffuse into the contracted type, due to the Hall effect.
Vacuum arc – diffuse or contracted Starting at the anode, the arc contracts and as the current
Following contact separation, single melting points form over rises further it tends to become sharply defined. Near the area
the entire surface of the cathode, producing metal vapours involved there is an increase in temperature with consequent
which support the arc. thermal stress on the contact.
The diffuse vacuum arc is characterised by expansion over To prevent overheating and erosion of the contacts, the arc is
the contact surface and by an even distribution of thermal kept rotating. With arc rotation it becomes similar to a moving
stress on the contact surfaces. conductor which the current passes through.

Provided by Northeast Power Systems, Inc.


www.nepsi.com
1
2

3
Diffuse arc. Contraction Contraction over
4 over anode. anode and cathode.

5
Schematic diagram of the transition from a diffuse arc to a contracted arc
in a vacuum interrupter.
6
7

10

1 Stem/terminal 7 Shield
2 Twist protection 8 Contacts
3 Bellows 9 Terminal
4 Interrupter housing 10 Interrupter housing
5 Shield
6 Ceramic insulator

Vacuum interrupter

6
The spiral geometry of ABB vacuum interrupter contacts Apart from minimising thermal stress on the contacts, all
The special geometry of the spiral contacts generates a radial this makes contact erosion negligible and, above all, allows
magnetic field in all areas of the arc column, concentrated the interruption process to be controlled even with very high
over the contact circumferences. short-circuits.
An electromagnetic force is self-generated and this acts ABB vacuum interrupters are zero-current interrupters and are
tangentially, causing rapid arc rotation around the contact free of any re-striking.
axis. Rapid reduction in the current charge and rapid condensation
This means the arc is forced to rotate and to involve a wider of the metal vapours simultaneously with the zero current,
surface than that of a fixed contracted arc. allows maximum dielectric strength to be restored between
the interrupter contacts within microseconds.

Provided by Northeast Power Systems, Inc.


www.nepsi.com
Short-circuit
current
Corrent, Voltage

Arc voltage
System
voltage
Short-circuit current
interruption

Time
Contact
separation

Recovery voltage
(system frequency)

Transient recovery voltage (TRV)


(high frequency)

Radial magnetic field contact Development of current and voltage trends during a single phase vacuum interruption process.
arrangement with a rotating
vacuum arc.

7
1. Description

Versions available • Highly reliable operating mechanisms thanks to a low


number of components which are manufactured using
The VD4 circuit-breakers are available in the fixed and
production systems for large quantities
withdrawable version with front operating mechanism.
• Extremely limited and simple maintenance
The withdrawable version is available for UniGear ZS1, ZS8.2
• Accessories common to the entire range
and UniSec switchgear and for PowerCube and Powerbloc
• Electrical accessories that can be easily and quickly
enclosures.
installed or replaced thanks to wiring pre-engineered
with plug-socket connectors
Fields of application • Mechanical anti-pumping device is supplied as
The VD4 circuit-breakers are used in power distribution for standard
control and protection of cables, overhead lines, transformer • Built-in closing spring charging lever
and distribution substations, motors, transformers, generators • Key lock with circuit-breaker open
and capacitor banks. • Protective covering over the opening and closing
pushbuttons to be operated using a special tool

Provided by Northeast Power Systems, Inc.


• Padlock device on the operating pushbuttons
Standards
The VD4 circuit-breakers comply with the IEC 62271-100,
VDE 0671-part. 100, CEI EN 62271-100 file 7642 (2005-
5) Standards and with those of the major industrialised
countries.
The VD4 circuit-breakers have undergone the tests indicated

www.nepsi.com
below and guarantee the safety and reliability of the apparatus Accessories
in service in any installation. The VD4 circuit-breakers have a complete range of
• Type tests: heating, withstand insulation at power frequency, accessories to satisfy all installation requirements.
The operating mechanism has a standardised range of
withstand insulation at lightning impulse, short-time and peak
accessories and spare parts which are easy to identify and
withstand current, mechanical life, short-circuit current making order.
and breaking capacity. The accessories are installed conveniently from the front of
• Individual tests: insulation of the main circuits with the circuit-breaker. Electrical connection is carried out with
voltage at power frequency, auxiliary circuit and operating plug-socket connectors.
mechanism insulation, measurement of the main circuit Use, maintenance and service of the apparatus are simple
resistance, mechanical and electrical operation. and require limited use of resources.

Service safety
Thanks to the complete range of mechanical and electrical
locks (available on request), it is possible to construct safe
distribution switchgear with the VD4 circuit-breakers.
The locking devices have been studied to prevent incorrect
operations and to inspect the installations whilst guaranteeing
maximum operator safety.
Key locks or padlock devices enable opening and closing
operations and/or racking in and racking out.
The racking-out device with the door closed allows the circuit-
breaker to be racked into or out of the switchgear only with
the door closed.
Anti-racking-in locks prevent circuit-breakers with different
rated currents from being racked in, and the racking-in and
racking out operation with the circuit-breaker closed.

8
O

Provided by Northeast Power Systems, Inc.


N

M
L

www.nepsi.com
I

A B C D E P

Circuit-breaker operating mechanism G Signalling device for closing springs charged/discharged


A Open/closed auxiliary contacts H Service releases
B Geared motor for closing spring charging I Closing pushbutton
C Built-in closing spring charging lever L Opening pushbutton
D Mechanical signalling device for circuit-breaker M Operating mechanism locking electromagnet
open/closed N Additional shunt opening release
E Mechanical operation counter O Transient contact
F Plug-socket connectors of electrical accessories P Contacts for signalling spring charged/discharged
in the truck

9
1. Description

General characteristics of the complete VD4 series (*)


The VD4 series of vacuum circuit-breakers conform to the
specifications of the following standards:
• VDE 00670, part 1000 IEC 62271-1
• VDE 00671, part 100 IEC 62271-100
• CEI EN 62271-100 File 7642 (2005-5)

(*) For information about the 12 kV • 1250 ... 4000 A • 50/63 kA and 36/40.5 kV
• 630 ... 2500 A • 16 ... 40 kA circuit-breakers, please see technical catalogue
GCBA520PO102.

Rated voltage (1)


kV 12
Rated frequency Hz 50 - 60

Provided by Northeast Power Systems, Inc.


Rated normal current A 630 . . . 4000 (2)
Short-time withstand current and breaking capacity kA 16 ... 31.5 40 50 63
Making capacity kA 40 ... 80 100 125 (3)
158
Short-time withstand current s 3 3 3 3
Fixed / withdrawable version •/• •/• •/• •/–
d (mm) 150 - 275 210 - 275 210 - 275 275

www.nepsi.com
Maximum overall H H (mm) 205 - 310 310 310 310
dimensions c
a (mm) 450 - 700 570 - 700 600 - 750 750
d
(fixed version) b (mm) 424 424 459 459
a
b c (mm) 461 - 599 599 (5)
608 (7)
677
Weight kg 73 - 105 94 - 180 147 - 260 260
Embedded poles • • • -
Assembled poles - - - •

Technical documentation To go into technical and application aspects of the VD4 circuit-
breakers in depth, please ask us for the following publications:
– PowerCube modules code 1VCP000091
– Powerbloc modules code BA441/03E
– UniGear ZS1 switchgear code 1VCP000138
– ZS8.4 switchgear code L2288
– REF542plus unit code 1VTA100001
– PR512 protection unit code 1VCP000055

10
17.5 24 36 40,5
50 - 60 50 - 60 50-60 50-60

Provided by Northeast Power Systems, Inc.


630 . . . 4000 (2)
630 . . . 3150 (2)
630 … 3150 630 … 3150
16 ... 31.5 40 ... 50 16 ... 31.5 16 ... 31.5 16 … 40
40 ... 80 100 ... 125 40 ... 80 40 ... 80 40 … 100
3 3 3 3 4
•/• •/• •/• •/• •/•
150 - 275 210 - 275 210 - 275 275 280 - 360 (4) (1)
Test voltage according to IEC 62271-
1 Standards table 1a, VDE 0670, - part

www.nepsi.com
205 - 310 310 310 328 / 280 (6)
328 1000, list 2
450 - 700 570 - 700 570 - 700 786 / 853 (6)
895 (6)
- 1000
(2)
With forced ventilation
(3)
Higher values on request
424 424 424 492 / 789 (6)
555 - 686 (6)
(4)
360 mm for fixed version, 280 mm for
461 - 599 (5)
599 (5) (7)
631 - 661 876 / 973 (6)
1575 withdrawable version
(5)
Circuit-breaker with eat sink 616 mm
73 - 105 94 - 180 100 - 110 170 / 210 290 - 350 (2500 A)
• • • • •
(6)
Withdrawable version
(7)
Circuit-breaker with eat sink 634 mm
- - - • • (3150 A)

Quality System Environmental Management System


Complies with ISO 9001 Standards, certified by an Complies with ISO 14001 Standards, certified by an
independent organisation. independent organisation.

Test Laboratory Health and Safety Management System


Complies with UNI CEI EN ISO/IEC 17025 Standards, Complies with OHSAS 18001 Standards, certified by an
accredited by an independent organisation. independent organisation.

11
2. Selection and ordering
Withdrawable circuit-breakers

Fixed VD4 circuit-breaker (12 kV)

Circuit-breaker VD4 12 (1)


IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 12

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 12
Withstand voltage at 50 Hz Ud (1 min) [kV] 28
Impulse withstand voltage Up [kV] 75
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) Ir [A] 630 630 630 1250 1250 1250 1250 1250 1250 1250
16 16 16 16 16 16 — — — —

www.nepsi.com
20 20 20 20 20 20 — — — —
Rated breaking capacity 25 25 25 25 25 25 — — — —
(rated short-circuit breaking current Isc [kA]
symmetrical) 31.5 31.5 31.5 31.5 31.5 31.5 — — — —
— — — — — — 40 40 — —
— — — — — — — — 50 50
16 16 16 16 16 16 — — — —
20 20 20 20 20 20 — — — —
25 25 25 25 25 25 — — — —
Rated short-time withstand current (3s) Ik [kA]
31.5 31.5 31.5 31.5 31.5 31.5 — — — —
— — — — — — 40 40 — —
— — — — — — — — 50 50
40 40 40 40 40 40 — — — —
50 50 50 50 50 50 — — — —
63 63 63 63 63 63 — — — —
Making capacity Ip [kA]
80 80 80 80 80 80 — — — —
— — — — — — 100 100 — —
— — — — — — — — 125 125
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • • • • • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P H [mm] 461 461 461 461 461 461 589 589 610 610
Maximum W [mm] 450 570 700 450 570 700 570 700 600 750
overall
H D [mm] 424 424 424 424 424 424 424 424 459 459
dimensions
W D Pole distance P [mm] 150 210 275 150 210 275 210 275 210 275
Weight [kg] 73 75 79 73 75 79 84 84 146 158
TN 7405 7406 — 7405 7406 — — — — —
Standardised table of dimensions
1VCD — — 000051 — — 000051 003282 003285 003440 003441
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) Circuit-breakers up to 1250 A and 31.5 kA have polyamide poles.

12


12

Provided by Northeast Power Systems, Inc.


12
28
75
50-60
1600 1600 1600 1600 1600 1600 1600 2000 2000 2000 2000 2500 2500 2500 3150 3150
— — — — — — — — — — — — — — — —

www.nepsi.com
20 20 20 — — — — 20 20 — — 20 20 — 20 —
25 25 25 — — — — 25 25 — — 25 25 — 25 —
31.5 31.5 31.5 — — — — 31.5 31.5 — — 31,5 31.5 — 31.5 —
— — — 40 40 — — 40 40 — — — 40 — 40 —
— — — — — 50 50 — — 50 50 — — 50 — 50
— — — — — — — — — — — — — — — —
20 20 20 — — — — 20 20 — — 20 20 — 20 —
25 25 25 — — — — 25 25 — — 25 25 — 25 —
31.5 31.5 31.5 — — — — 31.5 31.5 — — 31.5 31.5 — 31.5 —
— — — 40 40 — — 40 40 — — — 40 — 40 —
— — — — — 50 50 — — 50 50 — — 50 — 50
— — — — — — — — — — — — — — — —
50 50 50 — — — — 50 50 — — 50 50 — 50 —
63 63 63 — — — — 63 63 — — 63 63 — 63 —
80 80 80 — — — — 80 80 — — 80 80 — 80 —
— — — 100 100 — — 100 100 — — — 100 — 100 —
— — — — — 125 125 — — 125 125 — — 125 — 125
• • • • • • • • • • • • • • • —
33 ... 60
10 ... 15
43 ... 75
60 ... 80
599 599 599 589 589 610 610 599 599 610 610 599 599 610 635 636
450 570 700 570 700 600 750 570 700 600 750 570 700 750 700 750
424 424 424 424 424 459 459 424 424 459 459 424 424 459 424 459
150 210 275 210 275 210 275 210 275 210 275 210 275 275 275 275
93 98 105 84 84 146 158 98 105 146 158 98 105 163 140 177
— 7407 7408 — — — — 7407 7408 — — 7407 7408 — — —
000050 — — 003282 003285 003440 003441 — — 003440 003441 — — 003441 000149 003443
- 5 ... + 40

13
2. Selection and ordering
Withdrawable circuit-breakers

Fixed VD4 circuit-breaker (17.5 kV)

Circuit-breaker VD4 17 (1)


IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 17.5

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 17.5
Withstand voltage at 50 Hz Ud (1 min) [kV] 38
Impulse withstand voltage Up [kV] 95
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) Ir [A] 630 630 630 1250 1250 1250 1250 1250 1250 1250
16 16 16 16 16 16 — — — —

www.nepsi.com
20 20 20 20 20 20 — — — —
Rated breaking capacity 25 25 25 25 25 25 — — — —
(rated short-circuit breaking Isc [kA]
current symmetrical) 31.5 31.5 31.5 31.5 31.5 31.5 — — — —
— — — — — — 40 40 — —
— — — — — — — — 50 50
16 16 16 16 16 16 — — — —
20 20 20 20 20 20 — — — —
25 25 25 25 25 25 — — — —
Rated short-time withstand current (3s) Ik [kA]
31.5 31.5 31.5 31.5 31.5 31.5 — — — —
— — — — — — 40 40 — —
— — — — — — — — 50 50
40 40 40 40 40 40 — — — —
50 50 50 50 50 50 — — — —
63 63 63 63 63 63 — — — —
Making capacity Ip [kA]
80 80 80 80 80 80 — — — —
— — — — — — 100 100 — —
— — — — — — — — 125 125
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • • • • • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P H [mm] 461 461 461 461 461 461 589 589 610 610
Maximum W [mm] 450 570 700 450 570 700 570 700 600 750
overall
H D [mm] 424 424 424 424 424 424 424 424 459 459
dimensions
W D Pole distance P [mm] 150 210 275 150 210 275 210 275 210 275
Weight [kg] 73 75 79 73 75 79 84 84 146 158
TN 7405 7406 — 7405 7406 — — — — —
Standardised table of dimensions
1VCD — — 000051 — — 000051 003282 003285 003440 003441
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) Circuit-breakers up to 1250 A and 31.5 kA have polyamide poles.

14


17.5

Provided by Northeast Power Systems, Inc.


17.5
38
95
50-60
1600 1600 1600 1600 1600 1600 2000 2000 2000 2000 2500 2500 2500 3150 3150
— — — — — — — — — — — — — — —

www.nepsi.com
20 20 — — — — 20 20 — — 20 20 — 20 —
25 25 — — — — 25 25 — — 25 25 — 25 —
31.5 31.5 — — — — 31.5 31.5 — — 31.5 31.5 — 31.5 —
— — 40 40 — — 40 40 — — — 40 — 40 —
— — — — 50 50 — — 50 50 — — 50 — 50
— — — — — — — — — — — — — — —
20 20 — — — — 20 20 — — 20 20 — 20 —
25 25 — — — — 25 25 — — 25 25 — 25 —
31.5 31.5 — — — — 31.5 31.5 — — 31.5 31.5 — 31.5 —
— — 40 40 — — 40 40 — — — 40 — 40 —
— — — — 50 50 — — 50 50 — — 50 — 50
— — — — — — — — — — — — — — —
50 50 — — — — 50 50 — — 50 50 — 50 —
63 63 — — — — 63 63 — — 63 63 — 63 —
80 80 — — — — 80 80 — — 80 80 — 80 —
— — 100 100 — — 100 100 — — — 100 — 100 —
— — — — 125 125 — — 125 125 — — 125 — 125
• • • • • • • • • • • • • • —
33 ... 60
10 ... 15
43 ... 75
60 ... 80
599 599 589 589 610 610 599 599 610 610 599 599 610 635 636
570 700 570 700 600 750 570 700 600 750 570 700 750 700 750
424 424 424 424 459 459 424 424 459 459 424 424 459 424 459
210 275 210 275 210 275 210 275 210 275 210 275 275 275 275
98 105 84 84 146 158 98 105 146 158 98 105 163 140 177
7407 7408 — — — — 7407 7408 — — 7407 7408 — — —
— — 003282 003285 003440 003441 — — 003440 003441 — — 003441 000149 003443
- 5 ... + 40

15
2. Selection and ordering
Withdrawable circuit-breakers

Fixed VD4 circuit-breaker (24 kV)

Circuit-breaker VD4 24
IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 24

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 24
Withstand voltage at 50 Hz Ud (1 min) [kV] 50
Impulse withstand voltage Up [kV] 125
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) Ir [A] 630 630 1250 1250 1600 2000 2500
16 16 16 16 16 16 –

www.nepsi.com
Rated breaking capacity 20 20 20 20 20 20 –
Isc [kA]
(rated short-circuit breaking current symmetrical) 25 25 25 25 25 25 25
– – 31.5 – 31.5 31.5 31.5
16 16 16 16 16 16 –
20 20 20 20 20 20 –
Rated short-time withstand current (3s) Ik [kA]
25 25 25 25 25 25 25
– – 31.5 – 31.5 31.5 31.5
40 40 40 40 40 40 –
50 50 50 50 50 50 –
Making capacity Ip [kA]
63 63 63 63 63 63 63
– – 80 – 80 80 80
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P
H [mm] 631 631 631 631 642 642 642
Maximum W [mm] 570 700 570 700 700 700 700
overall
H D [mm] 424 424 424 424 424 424 424
dimensions
W D Pole distance P [mm] 210 275 210 275 275 275 275
Weight [kg] 100 104 100/106 (1)
104 110 110 110
TN 7409 7410 7409 7410 7411 7411 7411
Standardised table of dimensions
1VCD – – 000172 (1)
– – – –
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) 31.5 kA version.

16
Fixed VD4 circuit-breaker (36 kV)

Circuit-breaker VD4 36
IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 36

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 36
Withstand voltage at 50 Hz Ud (1 min) [kV] 70
Impulse withstand voltage Up [kV] 170
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) Ir [A] 1250 1600 2000 2500 (*)
— — — —

www.nepsi.com
Rated breaking capacity
Isc [kA] 31,5 31,5 31,5 31,5
(rated short-circuit breaking current symmetrical)
— — — —
— — — —
Rated short-time withstand current (3s) Ik [kA] 31,5 31,5 31,5 31,5
— — — —
— — — —
Making capacity Ip [kA] 80 80 80 80
— — — —
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • •
Opening time [ms] 35 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 45 ... 75
Closing time [ms] 60 ... 80
P P H [mm] 564 564 564 —
Maximum W [mm] 778 778 778 ­—
overall
dimensions
H D [mm] 468 468 468 —
W D Pole distance P [mm] 275 275 275 —
Weight [kg] 150 150 170 —
Standardised table of dimensions TN 1VYN300901-LT 1VYN300901-LT 1VYN300901-LT —
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(*) Contact ABB.

17
2. Selection and ordering
Withdrawable circuit-breakers

Types of fixed version circuit-breakers available


Complete the circuit-breaker selected with the optional accessories indicated on the following pages.

VD4 fixed circuit-breaker without bottom and top terminals (12 kV)

Ur Isc Rated uninterrupted current (40°C) [A]


H=461 H=589 H=599 H=610 H=636
D=424 D=424 D=424 D=459 D=459
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 Circuit-breaker type
kV kA
l/g=217.5 l/g=238 l/g=237.5 l/g=237 l/g=237
P=150 P=210 P=275 P=210 P=275 P=150 P=210 P=275 P=210 P=275 P=275
W=450 W=570 W=700 W=570 W=700 W=450 W=570 W=700 W=600 W=750 W=750
16 630 VD4 12.06.16 p150

Provided by Northeast Power Systems, Inc.


20 630 VD4 12.06.20 p150
25 630 VD4 12.06.25 p150
31.5 630 VD4 12.06.32 p150
16 1250 VD4 12.12.16 p150
20 1250 VD4 12.12.20 p150
25 1250 VD4 12.12.25 p150

www.nepsi.com
31.5 1250 VD4 12.12.32 p150
20 1600 VD4 12.16.20 p150
25 1600 VD4 12.16.25 p150
31.5 1600 VD4 12.16.32 p150
16 630 VD4 12.06.16 p210
20 630 VD4 12.06.20 p210
25 630 VD4 12.06.25 p210
31.5 630 VD4 12.06.32 p210
16 1250 VD4 12.12.16 p210
20 1250 VD4 12.12.20 p210
12
25 1250 VD4 12.12.25 p210
31.5 1250 VD4 12.12.32 p210
40 1250 VD4 12.12.40 p210
50 1250 VD4 12.12.50 p210
20 1600 VD4 12.16.20 p210
25 1600 VD4 12.16.25 p210
31.5 1600 VD4 12.16.32 p210
40 1600 VD4 12.16.40 p210
50 1600 VD4 12.16.50 p210
20 2000 VD4 12.20.20 p210
25 2000 VD4 12.20.25 p210
31.5 2000 VD4 12.20.32 p210
40 2000 VD4 12.20.40 p210
50 2000 VD4 12.20.50 p210
20 2500 VD4 12.25.20 p210
25 2500 VD4 12.25.25 p210
31.5 2500 VD4 12.25.32 p210
H = Height of the circuit-breaker.
W = Width of the circuit-breaker.
D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
l/g = Distance between the bottom terminal and the resting surface of the circuit-breaker.
P = Pole horizontal centre distance.

18
VD4 fixed circuit-breaker without bottom and top terminals (12 kV)

Ur Isc Rated uninterrupted current (40°C) [A]


H=461 H=589 H=599 H=610 H=636
D=424 D=424 D=424 D=459 D=459
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 Circuit-breaker type
kV kA
l/g=217.5 l/g=238 l/g=237.5 l/g=237 l/g=237
P=150 P=210 P=275 P=210 P=275 P=150 P=210 P=275 P=210 P=275 P=275
W=450 W=570 W=700 W=570 W=700 W=450 W=570 W=700 W=600 W=750 W=750
16 630 VD4 12.06.16 p275

Provided by Northeast Power Systems, Inc.


20 630 VD4 12.06.20 p275
25 630 VD4 12.06.25 p275
31.5 630 VD4 12.06.32 p275
16 1250 VD4 12.12.16 p275
20 1250 VD4 12.12.20 p275
25 1250 VD4 12.12.25 p275

www.nepsi.com
31.5 1250 VD4 12.12.32 p275
40 1250 VD4 12.12.40 p275
50 1250 VD4 12.12.50 p275
20 1600 VD4 12.16.20 p275
25 1600 VD4 12.16.25 p275
31.5 1600 VD4 12.16.32 p275
40 1600 VD4 12.16.40 p275
50 1600 VD4 12.16.50 p275
12
20 2000 VD4 12.20.20 p275
25 2000 VD4 12.20.25 p275
31.5 2000 VD4 12.20.32 p275
40 2000 VD4 12.20.40 p275
50 2000 VD4 12.20.50 p275
20 2500 VD4 12.25.20 p275
25 2500 VD4 12.25.25 p275
31.5 2500 VD4 12.25.32 p275
40 2500 VD4 12.25.40 p275
50 2500 VD4 12.25.50 p275
20 3150 VD4 12.32.20 p275
25 3150 VD4 12.32.25 p275
31.5 3150 VD4 12.32.32 p275
40 3150 VD4 12.32.40 p275
50 3150 VD4 12.32.50 p275

H = Height of the circuit-breaker.


W = Width of the circuit-breaker.
D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
l/g = Distance between the bottom terminal and the resting surface of the circuit-breaker.
P = Pole horizontal centre distance.

19
2. Selection and ordering
Withdrawable circuit-breakers

VD4 fixed circuit-breaker without bottom and top terminals (17.5 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


H=461 H=589 H=599 H=610 H=635
D=424 D=424 D=424 D=459 D=459
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 Circuit-breaker type
kV kA
l/g=217.5 l/g=238 l/g=237.5 l/g=237 l/g=237.5
P=150 P=210 P=275 P=210 P=275 P=150 P=210 P=275 P=210 P=275 P=275
W=450 W=570 W=700 W=570 W=700 W=450 W=570 W=700 W=600 W=750 W=750
16 630 VD4 17.06.16 p150
20 630 VD4 17.06.20 p150
25 630 VD4 17.06.25 p150
31.5 630 VD4 17.06.32 p150
16 1250 VD4 17.12.16 p150

Provided by Northeast Power Systems, Inc.


20 1250 VD4 17.12.20 p150
25 1250 VD4 17.12.25 p150
31.5 1250 VD4 17.12.32 p150
16 630 VD4 17.06.16 p210
20 630 VD4 17.06.20 p210
25 630 VD4 17.06.25 p210

www.nepsi.com
31.5 630 VD4 17.06.32 p210
16 1250 VD4 17.12.16 p210
20 1250 VD4 17.12.20 p210
25 1250 VD4 17.12.25 p210
17.5 31.5 1250 VD4 17.12.32 p210
40 1250 VD4 17.12.40 p210
50 1250 VD4 17.12.50 p210
20 1600 VD4 17.16.20 p210
25 1600 VD4 17.16.25 p210
31.5 1600 VD4 17.16.32 p210
40 1600 VD4 17.16.40 p210
50 1600 VD4 17.16.50 p210
20 2000 VD4 17.20.20 p210
25 2000 VD4 17.20.25 p210
31.5 2000 VD4 17.20.32 p210
40 2000 VD4 17.20.40 p210
50 2000 VD4 17.20.50 p210
20 2500 VD4 17.25.20 p210
25 2500 VD4 17.25.25 p210
31.5 2500 VD4 17.25.32 p210
H = Height of the circuit-breaker.
W = Width of the circuit-breaker.
D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
l/g = Distance between the bottom terminal and the resting surface of the circuit-breaker.
P = Pole horizontal centre distance.

20
VD4 fixed circuit-breaker without bottom and top terminals (17.5 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


H=461 H=589 H=599 H=610 H=635
D=424 D=424 D=424 D=459 D=459
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 Circuit-breaker type
kV kA
l/g=217.5 l/g=238 l/g=237.5 l/g=237 l/g=237.5
P=150 P=210 P=275 P=210 P=275 P=150 P=210 P=275 P=210 P=275 P=275
W=450 W=570 W=700 W=570 W=700 W=450 W=570 W=700 W=600 W=750 W=750
16 630 VD4 17.06.16 p275
20 630 VD4 17.06.20 p275
25 630 VD4 17.06.25 p275
31.5 630 VD4 17.06.32 p275
16 1250 VD4 17.12.16 p275

Provided by Northeast Power Systems, Inc.


20 1250 VD4 17.12.20 p275
25 1250 VD4 17.12.25 p275
31.5 1250 VD4 17.12.32 p275
40 1250 VD4 17.12.40 p275
50 1250 VD4 17.12.50 p275
20 1600 VD4 17.16.20 p275

www.nepsi.com
25 1600 VD4 17.16.25 p275
31.5 1600 VD4 17.16.32 p275
40 1600 VD4 17.16.40 p275
50 1600 VD4 17.16.50 p275
17.5
20 2000 VD4 17.20.20 p275
25 2000 VD4 17.20.25 p275
31.5 2000 VD4 17.20.32 p275
40 2000 VD4 17.20.40 p275
50 2000 VD4 17.20.50 p275
20 2500 VD4 17.25.20 p275
25 2500 VD4 17.25.25 p275
31.5 2500 VD4 17.25.32 p275
40 2500 VD4 17.25.40 p275
50 2500 VD4 17.25.50 p275
20 3150 VD4 17.32.20 p275
25 3150 VD4 17.32.25 p275
31.5 3150 VD4 17.32.32 p275
40 3150 VD4 17.32.40 p275
50 3150 VD4 17.32.50 p275
H = Height of the circuit-breaker.
W = Width of the circuit-breaker.
D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
l/g = Distance between the bottom terminal and the resting surface of the circuit-breaker.
P = Pole horizontal centre distance.

21
2. Selection and ordering
Withdrawable circuit-breakers

VD4 fixed circuit-breaker without bottom and top terminals (24 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


H=631 H=642
D=424 D=424
u/l=310 u/l=310 Circuit-breaker type
kV kA
l/g=282.5 l/g=282.5
P=210 P=275 P=275
W=570 W=700 W=700
16 630 VD4 24.06.16 p210
20 630 VD4 24.06.20 p210
25 630 VD4 24.06.25 p210
16 1250 VD4 24.12.16 p210
20 1250 VD4 24.12.20 p210

Provided by Northeast Power Systems, Inc.


25 1250 VD4 24.12.25 p210
31.5 1250 VD4 24.12.32 p210
16 630 VD4 24.06.16 p275
20 630 VD4 24.06.20 p275
25 630 VD4 24.06.25 p275
16 1250 VD4 24.12.16 p275

www.nepsi.com
24 20 1250 VD4 24.12.20 p275
25 1250 VD4 24.12.25 p275
16 1600 VD4 24.16.16 p275
20 1600 VD4 24.16.20 p275
25 1600 VD4 24.16.25 p275
31.5 1600 VD4 24.16.32 p275
16 2000 VD4 24.20.16 p275
20 2000 VD4 24.20.20 p275
25 2000 VD4 24.20.25 p275
31.5 2000 VD4 24.20.32 p275
25 2500 VD4 24.25.25 p275
31.5 2500 VD4 24.25.32 p275
H = Height of the circuit-breaker.
W = Width of the circuit-breaker.
D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
l/g = Distance between the bottom terminal and the resting surface of the circuit-breaker.
P = Pole horizontal centre distance.

22
VD4 fixed circuit-breaker without bottom and top terminals (36 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


H=876
D=478.5
u/l=328
kV kA Circuit-breaker type
l/g=428.5
P=275
W=786
1250 A VD4 36.12.32 p275
1600 A VD4 36.16.32 p275
36 31.5
2000 A VD4 36.20.32 p275
2500 A (* ) VD4 36.25.32 p275
H = Height of the circuit-breaker.

Provided by Northeast Power Systems, Inc.


W = Width of the circuit-breaker.
D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
l/g = Distance between the bottom terminal and the resting surface of the circuit-breaker.
P = Pole horizontal centre distance.
(*) = Contact ABB.

www.nepsi.com
Standard fittings of fixed circuit-breakers
The basic versions of the fixed circuit-breakers are three-pole
and fitted with:
– EL type manual operating mechanism
– mechanical signalling device for closing springs charged/
discharged
– mechanical signalling device for circuit-breaker open/closed
– closing pushbutton, opening pushbutton and operation
counter
– set of ten auxiliary circuit-breaker break/make contacts
Note: with the group of ten auxiliary contacts supplied as standard and the
maximum number of electrical applications, three break contacts (signalling
circuit-breaker open) and five make contacts (signalling circuit-breaker
closed) are available.
– lever for manually charging the closing springs
– auxiliary circuit support terminal board.
VD4 - up to 24 kV VD4 - 36 kV

23
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable version circuit-breakers


for UniGear ZS1 switchgear (12 kV)

Circuit-breaker VD4/P 12 (3)


IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 12

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 12
Withstand voltage at 50 Hz Ud (1 min) [kV] 28
Impulse withstand voltage Up [kV] 75
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 1250 1250 1250 1600 1600
16 16 — — — — —

www.nepsi.com
20 20 — — — 20 20
Rated breaking capacity 25 25 — — — 25 25
Isc [kA]
(rated short-circuit breaking current symmetrical) 31.5 31.5 — — — 31.5 31.5
— — 40 40 — — —
— — — — 50 — —
16 16 — — — — —
20 20 — — — 20 20
25 25 — — — 25 25
Rated short-time withstand current (3s) Ik [kA]
31.5 31.5 — — — 31.5 31.5
— — 40 40 — — —
— — — — 50 — —
40 40 — — — — —
50 50 — — — 50 50
63 63 — — — 63 63
Making capacity Ip [kA]
80 80 — — — 80 80
— — 100 100 — — —
— — — — 125 — —
Operation sequence [ O - 0.3 s - CO - 15 s - CO ] • • • • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P
H [mm] 628 628 691 691 691 691 691
Maximum W [mm] 503 503 653 853 681 653 853
overall H
dimensions D [mm] 662 662 641 642 643 642 642
W D Pole distance P [mm] 150 150 210 275 210 210 275
Weight [kg] 116 116 174 176 180 160 166
TN 7412 7412 — — — 7415 7416
Standardised table of dimensions
1VCD — — 003284 003286 003444 — —
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) Rated current guaranteed with circuit-breaker installed in UniGear ZS1 switchgear and with 40 °C ambient temperature.
(2) Up to 4000 A with forced ventilation.
(3) Circuit-breakers up to 1250 A and 31.5 kA have polyamide poles.

24


12

Provided by Northeast Power Systems, Inc.


12
28
75
50-60
1600 1600 1600 1600 2000 2000 2000 2000 2500 2500 3150 (2)
3150 (2)

— — — — — — — — — — — —

www.nepsi.com
— — — — 20 20 — — 20 — 20 —
— — — — 25 25 — — 25 — 25 —
— — — — 31.5 31.5 — — 31.5 — 31.5 —
40 40 — — 40 40 — — 40 — 40 —
— — 50 50 — — 50 50 — 50 — 50
— — — — — — — — — — — —
— — — — 20 20 — — 20 — 20 —
— — — — 25 25 — — 25 — 25 —
— — — — 31.5 31.5 — — 31.5 — 31.5 —
40 40 — — 40 40 — — 40 — 40 —
— — 50 50 — — 50 50 — 50 — 50
— — — — — — — — — — — —
— — — — 50 50 — — 50 — 50 —
— — — — 63 63 — — 63 — 63 —
— — — — 80 80 — — 80 — 80 —
100 100 — — 100 100 — — 100 — 100 —
— — 125 125 — — 125 125 — 125 — 125
• • • • • • • • • • • •
33 ... 60
10 ... 15
43 ... 75
60 ... 80
691 691 691 691 691 691 691 691 691 691 730 742
653 853 681 853 653 853 681 853 853 853 853 853
641 642 643 643 642 642 643 643 640 643 640 643
210 275 210 275 210 275 210 275 275 275 275 275
174 176 180 193 160 166 190 205 186 225 221 240
— — — — 7415 7416 — — 7417 — — —
003284 003286 003444 003445 — — 003444 003445 — 003446 000153 003447
- 5 ... + 40

25
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable version circuit-breakers


for UniGear ZS1 switchgear (17.5 kV)

Circuit-breaker VD4/P 17 (3)


IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 17.5

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 17.5
Withstand voltage at 50 Hz Ud (1 min) [kV] 38
Impulse withstand voltage Up [kV] 95
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 1250 1250 1250 1600 1600
16 16 — — — — —

www.nepsi.com
20 20 — — — 20 20
Rated breaking capacity 25 25 — — — 25 25
Isc [kA]
(rated short-circuit breaking current symmetrical) 31.5 31.5 — — — 31.5 31.5
— — 40 40 — — —
— — — — 50 — —
16 16 — — — — —
20 20 — — — 20 20
25 25 — — — 25 25
Rated short-time withstand current (3s) Ik [kA]
31.5 31.5 — — — 31.5 31.5
— — 40 40 — — —
— — — — 50 — —
40 40 — — — — —
50 50 — — — 50 50
63 63 — — — 63 63
Making capacity Ip [kA]
80 80 — — — 80 80
— — 100 100 — — —
— — — — 125 — —
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P H [mm] 632 632 691 691 691 691 691
Maximum W [mm] 503 503 653 853 681 653 853
overall
H D [mm] 664 664 641 642 643 642 642
dimensions
W D Pole distance P [mm] 150 150 210 275 210 210 275
Weight [kg] 116 116 174 176 180 160 166
TN 7412 7412 — — — 7415 7416
Standardised table of dimensions
1VCD — — 003284 003286 003444 — —
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) Rated current guaranteed with circuit-breaker installed in UniGear ZS1 switchgear and with 40 °C ambient temperature.
(2) Up to 4000 A with forced ventilation.
(3) Circuit-breakers up to 1250 A and 31.5 kA have polyamide poles.

26


17,5

Provided by Northeast Power Systems, Inc.


17,5
38
95
50-60
1600 1600 1600 1600 2000 2000 2000 2000 2500 2500 3150 (2)
3150 (2)

— — — — — — — — — — — —

www.nepsi.com
— — — — 20 20 — — 20 — 20 —
— — — — 25 25 — — 25 — 25 —
— — — — 31,5 31,5 — — 31,5 — 31,5 —
40 40 — — 40 40 — — 40 — 40 —
— — 50 50 — — 50 50 — 50 — 50
— — — — — — — — — — — —
— — — — 20 20 — — 20 — 20 —
— — — — 25 25 — — 25 — 25 —
— — — — 31,5 31,5 — — 31,5 — 31,5 —
40 40 — — 40 40 — — 40 — 40 —
— — 50 50 — — 50 50 — 50 — 50
— — — — — — — — — — — —
— — — — 50 50 — — 50 — 50 —
— — — — 63 63 — — 63 — 63 —
— — — — 80 80 — — 80 — 80 —
100 100 — — 100 100 — — 100 — 100 —
— — 125 125 — — 125 125 — 125 — 125
• • • • • • • • • • • •
33 ... 60
10 ... 15
43 ... 75
60 ... 80
691 691 691 691 691 691 691 691 691 691 730 742
653 853 681 853 653 853 681 853 853 853 853 853
641 642 643 643 642 642 643 643 640 643 640 643
210 275 210 275 210 275 210 275 275 275 275 275
174 176 180 193 160 166 190 205 186 225 221 240
— — — — 7415 7416 — — 7417 — — —
003284 003286 003444 003445 — — 003444 003445 — 003446 000153 003447
- 5 ... + 40

27
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable version circuit-breakers


for UniGear ZS1 switchgear (24 kV)

Circuit-breaker VD4/P 24
IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 24

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 24
Withstand voltage at 50 Hz Ud (1 min) [kV] 50
Impulse withstand voltage Up [kV] 125
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 630 1250 1250 1600 2000 2500 (2)
3150 (3)

16 16 16 16 16 16 16 –

www.nepsi.com
Rated breaking capacity 20 20 20 20 20 20 20 –
(rated short-circuit breaking current Isc [kA]
symmetrical) 25 25 25 25 25 25 25 –
– – 31.5 – 31.5 31.5 31.5 31.5
16 16 16 16 16 16 16 –
20 20 20 20 20 20 20 –
Rated short-time withstand current (3s) Ik [kA]
25 25 25 25 25 25 25 –
– – 31.5 – 31.5 31.5 31.5 31.5
40 40 40 40 40 40 40 –
50 50 50 50 50 50 50 –
Making capacity Ip [kA]
63 63 63 63 63 63 63 –
– – 80 – 80 80 80 80
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • • • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P
H [mm] 794 794 794 794 838 838 838 838
Maximum W [mm] 653 853 653 853 853 853 853 853
overall
H D [mm] 802 802 802 802 790 790 790 790
dimensions
W D Pole distance P [mm] 210 275 210 275 275 275 275 275
Weight [kg] 140 148 140/146 (4)
148 228 228 228 277
TN 7413 7414 7413 7414 7418 7418 7418 –
Standardised table of dimensions
1VCD – – 000173 (4)
– – – – 000177
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) Rated current guaranteed with circuit-breaker installed in UniGear ZS1 switchgear and with 40 °C ambient temperature.
(2) 2300 A rated current guaranteed with natural ventilation; 2500 A rated current guaranteed with forced ventilation.
(3) 2700 A rated current guaranteed with natural ventilation; 3150 A rated current guaranteed with forced ventilation.
(4) 31.5 kA version.

28
General characteristics of withdrawable circuit-breakers
for UniGear ZS2 and PowerCube modules (36 kV)

Circuit-breaker VD4/W 36
IEC 62271-100 •
Standards
VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 36

Provided by Northeast Power Systems, Inc.


Rated insulation voltage Us [kV] 36
Withstand voltage at 50 Hz Ud (1 min) [kV] 70
Impulse withstand voltage Up [kV] 170
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) (1)
Ir [A] 1250 1600 2000 2500 (*)
— — — —

www.nepsi.com
Rated breaking capacity
Isc [kA] 31,5 31,5 31,5 31,5
(rated short-circuit breaking current symmetrical)
— — — —
— — — —
Rated short-time withstand current (3s) Ik [kA] 31,5 31,5 31,5 31,5
— — — —
— — — —
Making capacity Ip [kA] 80 80 80 80
— — — —
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 45 ... 75
Closing time [ms] 60 ... 80
P P H [mm] 973 973 973 973
Maximum W [mm] 842 842 842 842
overall
H D [mm] 788 788 788 788
dimensions
W D Pole distance P [mm] 275 275 275 275
Weight [kg] 230 230 230 —
Standardised table of dimensions TN 1VYN300901-KG 1VYN300901-KG 1VYN300901-KG —
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(*) Ask ABB

29
2. Selection and ordering
Withdrawable circuit-breakers

Types of withdrawable version circuit-breakers available for UniGear ZS1 switchgear


Complete the circuit-breaker selected with the optional accessories indicated on the following pages.

VD4 (12 kV) withdrawable circuit-breaker

Ur Isc Rated uninterrupted current (40 °C) [A]


W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
16 630 VD4/P 12.06.16 p150

Provided by Northeast Power Systems, Inc.


20 630 VD4/P 12.06.20 p150
25 630 VD4/P 12.06.25 p150
31.5 630 VD4/P 12.06.32 p150
16 1250 VD4/P 12.12.16 p150
20 1250 VD4/P 12.12.20 p150
25 1250 VD4/P 12.12.25 p150

www.nepsi.com
31.5 1250 VD4/P 12.12.32 p150
40 1250 VD4/P 12.12.40 p210
50 1250 VD4/P 12.12.50 p210
20 1600 VD4/P 12.16.20 p210
25 1600 VD4/P 12.16.25 p210
31.5 1600 VD4/P 12.16.32 p210
40 1600 VD4/P 12.16.40 p210
50 1600 VD4/P 12.16.50 p210
12 20 2000 VD4/P 12.20.20 p210
25 2000 VD4/P 12.20.25 p210
31.5 2000 VD4/P 12.20.32 p210
40 2000 VD4/P 12.20.40 p210
50 2000 VD4/P 12.20.50 p210
40 1250 VD4/P 12.12.40 p275
20 1600 VD4/P 12.16.20 p275
25 1600 VD4/P 12.16.25 p275
31.5 1600 VD4/P 12.16.32 p275
40 1600 VD4/P 12.16.40 p275
50 1600 VD4/P 12.16.50 p275
20 2000 VD4/P 12.20.20 p275
25 2000 VD4/P 12.20.25 p275
31.5 2000 VD4/P 12.20.32 p275
40 2000 VD4/P 12.20.40 p275
50 2000 VD4/P 12.20.50 p275
W = Width of the circuit-breaker.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.

30
VD4 (12 kV) withdrawable circuit-breaker

Ur Isc Rated uninterrupted current (40 °C) [A]


W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
20 2500 VD4/P 12.25.20 p275

Provided by Northeast Power Systems, Inc.


25 2500 VD4/P 12.25.25 p275
31,5 2500 VD4/P 12.25.32 p275
40 2500 VD4/P 12.25.40 p275
50 2500 VD4/P 12.25.50 p275
12
20 3150 (1) VD4/P 12.32.20 p275
25 3150 (1)
VD4/P 12.32.25 p275

www.nepsi.com
31,5 3150 (1)
VD4/P 12.32.32 p275
40 3150 (1)
VD4/P 12.32.40 p275
50 3150 (1)
VD4/P 12.32.50 p275
W = Width of the circuit-breaker.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.
(1) Up to 4000 A with forced ventilation.

31
2. Selection and ordering
Withdrawable circuit-breakers

VD4 (17.5 kV) withdrawable circuit-breaker for UniGear ZS1 switchboard

Ur Isc Rated uninterrupted current (40 °C) [A]


W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
16 630 VD4/P 17.06.16 p150
20 630 VD4/P 17.06.20 p150
25 630 VD4/P 17.06.25 p150
31.5 630 VD4/P 17.06.32 p150
16 1250 VD4/P 17.12.16 p150
20 1250 VD4/P 17.12.20 p150
25 1250 VD4/P 17.12.25 p150

Provided by Northeast Power Systems, Inc.


31.5 1250 VD4/P 17.12.32 p150
40 1250 VD4/P 17.12.40 p210
50 1250 VD4/P 17.12.50 p210
20 1600 VD4/P 17.16.20 p210
25 1600 VD4/P 17.16.25 p210
31.5 1600 VD4/P 17.16.32 p210

www.nepsi.com
40 1600 VD4/P 17.16.40 p210
50 1600 VD4/P 17.16.50 p210
17.5 20 2000 VD4/P 17.20.20 p210
25 2000 VD4/P 17.20.25 p210
31.5 2000 VD4/P 17.20.32 p210
40 2000 VD4/P 17.20.40 p210
50 2000 VD4/P 17.20.50 p210
40 1250 VD4/P 17.12.40 p275
20 1600 VD4/P 17.16.20 p275
25 1600 VD4/P 17.16.25 p275
31.5 1600 VD4/P 17.16.32 p275
40 1600 VD4/P 17.16.40 p275
50 1600 VD4/P 17.16.50 p275
20 2000 VD4/P 17.20.20 p275
25 2000 VD4/P 17.20.25 p275
31.5 2000 VD4/P 17.20.32 p275
40 2000 VD4/P 17.20.40 p275
50 2000 VD4/P 17.20.50 p275
W = Width of the circuit-breaker.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.

32
VD4 (17.5 kV) withdrawable circuit-breaker for UniGear ZS1 switchboard

Ur Isc Rated uninterrupted current (40 °C) [A]


W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
20 2500 VD4/P 17.25.20 p275
25 2500 VD4/P 17.25.25 p275
31.5 2500 VD4/P 17.25.32 p275
40 2500 VD4/P 17.25.40 p275
50 2500 VD4/P 17.25.50 p275
17.5
20 3150 (1)
VD4/P 17.32.20 p275
25 3150 (1)
VD4/P 17.32.25 p275

Provided by Northeast Power Systems, Inc.


31.5 3150 (1)
VD4/P 17.32.32 p275
40 3150 (1)
VD4/P 17.32.40 p275
50 3150 (1)
VD4/P 17.32.50 p275
W = Width of the circuit-breaker.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.

www.nepsi.com
(1) Up to 4000 A with forced ventilation.

33
2. Selection and ordering
Withdrawable circuit-breakers

VD4 (24 kV) withdrawable circuit-breaker for UniGear ZS1 switchboard

Ur Isc Rated uninterrupted current (40 °C) [A]


W=800 W=1000 W=1000 W=1000
P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=35 ø=79 ø=109
16 630 VD4/P 24.06.16 p210
20 630 VD4/P 24.06.20 p210
25 630 VD4/P 24.06.25 p210
16 1250 VD4/P 24.12.16 p210
20 1250 VD4/P 24.12.20 p210
25 1250 VD4/P 24.12.25 p210
31.5 1250 VD4/P 24.12.32 p210

Provided by Northeast Power Systems, Inc.


16 630 VD4/P 24.06.16 p275
20 630 VD4/P 24.06.20 p275
25 630 VD4/P 24.06.25 p275
16 1250 VD4/P 24.12.16 p275
20 1250 VD4/P 24.12.20 p275
25 1250 VD4/P 24.12.25 p275

www.nepsi.com
24
16 1600 VD4/P 24.16.16 p275
20 1600 VD4/P 24.16.20 p275
25 1600 VD4/P 24.16.25 p275
31.5 1600 VD4/P 24.16.32 p275
16 2000 VD4/P 24.20.16 p275
20 2000 VD4/P 24.20.20 p275
25 2000 VD4/P 24.20.25 p275
31.5 2000 VD4/P 24.20.32 p275
16 2300 (1)
VD4/P 24.25.16 p275
20 2300 (1)
VD4/P 24.25.20 p275
25 2300 (1)
VD4/P 24.25.25 p275
31.5 2300 (1)
VD4/P 24.25.32 p275
31.5 2700 (2)
VD4/P 24.32.32 p275
W = Width of the switchgear.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.
(1) 2500 A rated current guaranteed with forced ventilation.
(2) 3150 A rated current guaranteed with forced ventilation.

34
VD4 (36 kV) withdrawable circuit-breaker

Ur Isc Rated uninterrupted current (40 °C) [A]


H=951
D=788
u/l=380
kV kA Circuit-breaker type
ø=399
P=275
W=778
1250 A VD4/W 36.12.32 p275
1600 A VD4/W 36.16.32 p275
36 31.5
2000 A VD4/W 36.20.32 p275
2500 A * ( )
VD4/W 36.25.32 p275
H = Height of the circuit-breaker.

Provided by Northeast Power Systems, Inc.


D = Depth of the circuit-breaker.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.
P = Pole horizontal centre distance.
W = Width of the circuit-breaker.
(*) = Contact ABB.

www.nepsi.com
Standard fittings of withdrawable circuit-breakers – locking electromagnet in the truck (compulsory for ABB
for UniGear ZS1, ZS2 switchgear and similar panels switchgear). This device prevents racking the circuit-breaker
into the switchgear with the auxiliary circuits disconnected
The basic versions of the withdrawable circuit-breakers are
(plug not inserted in the socket)
three-pole and fitted with:
– door interlock (compulsory for ABB switchgear); this device
– EL type manual operating mechanism
prevents racking the circuit-breaker into the switchgear
– mechanical signalling device for closing springs charged/
when the switchgear door is open.
discharged
– mechanical signalling device for circuit-breaker open/closed
– closing pushbutton
– opening pushbutton
– operation counter
– set of ten circuit-breaker open/closed auxiliary contacts
Note: with the group of ten auxiliary contacts supplied as standard and the
maximum number of electrical applications, three break contacts (signalling
circuit-breaker open) and four make contacts (signalling circuit-breaker closed)
are available.
– lever for manually charging the closing springs
– isolating contacts
– cord with connector (plug only) for auxiliary circuits, with
striker pins which does not allow the plug to be inserted
into the socket if the rated current of the circuit-breaker is
lower than the rated current of the panel
– racking-out/in lever (the quantity must be defined according
to the number of pieces of apparatus ordered)

VD4 – up to 24 kV VD4 - 36 kV

35
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable version circuit-breakers


for PowerCube modules (12 kV)

Circuit-breaker VD4/P 12 ( 3) VD4/W 12 (3)


PowerCube module PB1 PB2
IEC 62271-100 • •
Standards
VDE 0671; CEI EN 62271-100- File 7642 • •

Provided by Northeast Power Systems, Inc.


Rated voltage Ur [kV] 12 12
Rated insulation voltage Us [kV] 12 12
Withstand voltage at 50 Hz Ud (1 min) [kV] 28 28
Impulse withstand voltage Up [kV] 75 75
Rated frequency fr [Hz] 50-60 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 630 1250

www.nepsi.com
16 16 16 16
20 20 20 20
Rated breaking capacity 25 25 25 25
(rated short-circuit breaking Isc [kA]
current symmetrical) 31.5 31.5 31.5 31.5
— — — —
— — — —
16 16 16 16
20 20 20 20
Rated short-time 25 25 25 25
Ik [kA]
withstand current (3s) 31.5 31.5 31.5 31.5
— — — —
— — — —
40 40 40 40
50 50 50 50
63 63 63 63
Making capacity Ip [kA]
80 80 80 80
— — — —
— — — —
Operation sequence [O - 0.3 s - CO - 15 s - CO] • •
Opening time [ms] 33 ... 60 33 ... 60
Arcing time [ms] 10 ... 15 10 ... 15
Total breaking time [ms] 43 ... 75 43 ... 75
Closing time [ms] 60 ... 80 60 ... 80
P P
H [mm] 628 628 691 691
Maximum W [mm] 503 503 653 853
overall H
dimensions D [mm] 662 662 642 642
W D Pole distance P [mm] 150 150 210 210
Weight [kg] 116 116 135 135
TN 7412 7412 7420 7420
Standardised table of dimensions
1VCD — — — —
Operating temperature [°C] - 5 ... + 40 - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 • •
Electromagnetic compatibility IEC: 62271-1 • •
(1) Rated current guaranteed with circuit-breaker installed in PowerCube enclosure and with 40 °C ambient temperature
(2) Up to 4000 A with forced ventilation.
(3) Circuit-breakers up to 1250 A and 31.5 kA have polyamide poles.

36
VD4/P 12 VD4/W 12
PB2 PB3 PB3
• • •
• • •

Provided by Northeast Power Systems, Inc.


12 12 12
12 12 12
28 28 28
75 75 75
50-60 50-60 50-60
1250 1250 1600 1600 1600 2000 2000 2500 2500 3150 (2)
3150 (2)

www.nepsi.com
— — — — — — — — — — —
— — 20 — — 20 — 20 — 20 —
— — 25 — — 25 — 25 — 25 —
— — 31.5 — — 31.5 — 31.5 — 31.5 —
40 — — 40 — 40 — 40 — 40 —
— 50 — — 50 — 50 — 50 — 50
— — — — — — — — — — —
— — 20 — — 20 — 20 — 20 —
— — 25 — — 25 — 25 — 25 —
— — 31.5 — — 31.5 — 31.5 — 31.5 —
40 — — 40 — 40 — 40 — 40 —
— 50 — — 50 — 50 — 50 — 50
— — — — — — — — — — —
— — 50 — — 50 — 50 — 50 —
— — 63 — — 63 — 63 — 63 —
— — 80 — — 80 — 80 — 80 —
100 — — 100 — 100 — 100 — 100 —
— 125 — — 125 — 125 — 125 — 125
• • •
33 ... 60 33 ... 60 33 ... 60
10 ... 15 10 ... 15 10 ... 15
43 ... 75 43 ... 75 43 ... 75
60 ... 80 60 ... 80 60 ... 80
691 691 691 691 691 690 691 691 691 730 691
653 681 653 653 681 653 681 853 853 853 853
641 643 642 641 643 642 643 640 643 640 643
210 210 210 210 210 210 210 275 275 275 275
174 180 160 174 180 160 190 186 225 221 240
— — 7415 — — 7415 — 7417 — — —
003284 003444 — 003284 003444 — 003444 — 003445 000152 003596
- 5 ... + 40 - 5 ... + 40 - 5 ... + 40
• • •
• • •

37
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable version circuit-breakers


for PowerCube modules (17.5 kV)

Circuit-breaker VD4/P 17 ( 3) VD4/W 17 (3)


PowerCube module PB1 PB2
IEC 62271-100 • •
Standards
VDE 0671; CEI EN 62271-100- File 7642 • •

Provided by Northeast Power Systems, Inc.


Rated voltage Ur [kV] 17.5 17.5
Rated insulation voltage Us [kV] 17.5 17.5
Withstand voltage at 50 Hz Ud (1 min) [kV] 38 38
Impulse withstand voltage Up [kV] 95 95
Rated frequency fr [Hz] 50-60 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 630 1250

www.nepsi.com
16 16 16 16
20 20 20 20
Rated breaking capacity 25 25 25 25
(rated short-circuit breaking Isc [kA]
current symmetrical) 31.5 31.5 31.5 31.5
— — — —
— — — —
16 16 16 16
20 20 20 20
Rated short-time 25 25 25 25
Ik [kA]
withstand current (3s) 31.5 31.5 31.5 31.5
— — — —
— — — —
40 40 40 40
50 50 50 50
63 63 63 63
Making capacity Ip [kA]
80 80 80 80
— — — —
— — — —
Operation sequence [O - 0.3 s - CO - 15 s - CO] • •
Opening time [ms] 33 ... 60 33 ... 60
Arcing time [ms] 10 ... 15 10 ... 15
Total breaking time [ms] 43 ... 75 43 ... 75
Closing time [ms] 60 ... 80 60 ... 80
P P
H [mm] 628 628 691 691
Maximum W [mm] 503 503 653 853
overall
H D [mm] 662 662 642 642
dimensions
W D Pole distance P [mm] 150 150 210 210
Weight [kg] 116 116 135 135
TN 7412 7412 7420 7420
Standardised table of dimensions
1VCD — — — —
Operating temperature [°C] - 5 ... + 40 - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 • •
Electromagnetic compatibility IEC: 62271-1 • •
(1) Rated current guaranteed with circuit-breaker installed in PowerCube enclosure and with 40 °C ambient temperature.
(2) Up to 4000 A with forced ventilation.
(3) Circuit-breakers up to 1250 A and 31.5 kA have polyamide poles.

38
VD4/P 17 VD4/W 17
PB2 PB3 PB3
• • •
• • •

Provided by Northeast Power Systems, Inc.


17,5 17,5 17,5
17,5 17,5 17,5
38 38 38
95 95 95
50-60 50-60 50-60
1250 1250 1600 1600 1600 2000 2000 2500 2500 3150 (2)
3150 (2)

www.nepsi.com
— — — — — — — — — — —
— — 20 — — 20 — 20 — — 20
— — 25 — — 25 — 25 — — 25
— — 31.5 — — 31.5 — 31.5 — — 31.5
40 — — 40 — 40 — 40 — — 40
— 50 — — 50 — 50 — 50 50 —
— — — — — — — — — — —
— — 20 — — 20 — 20 — — 20
— — 25 — — 25 — 25 — — 25
— — 31.5 — — 31.5 — 31.5 — — 31.5
40 — — 40 — 40 — 40 — — 40
— 50 — — 50 — 50 — 50 50 —
— — — — — — — — — — —
— — 50 — — 50 — 50 — — 50
— — 63 — — 63 — 63 — — 63
— — 80 — — 80 — 80 — — 80
100 — — 100 — 100 — 100 — — 100
— 125 — — 125 — 125 — 125 125 —
• • •
33 ... 60 33 ... 60 33 ... 60
10 ... 15 10 ... 15 10 ... 15
43 ... 75 43 ... 75 43 ... 75
60 ... 80 60 ... 80 60 ... 80
691 691 691 691 691 690 691 691 691 691 730
653 681 653 653 681 653 681 853 853 853 853
641 643 642 641 643 642 643 640 643 643 640
210 210 210 210 210 210 210 275 275 275 275
174 180 160 174 180 160 190 186 225 240 221
— — 7415 — — 7415 — 7417 — — —
003284 003444 — 003284 003444 — 003444 — 003445 003596 000152
- 5 ... + 40 - 5 ... + 40 - 5 ... + 40
• • •
• • •

39
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable version circuit-breakers


for PowerCube modules (24 kV)

Circuit-breaker VD4/P 24
PowerCube module PB4 PB5
IEC 62271-100 • •
Standards
VDE 0671; CEI EN 62271-100- File 7642 • •

Provided by Northeast Power Systems, Inc.


Rated voltage Ur [kV] 24 24
Rated insulation voltage Us [kV] 24 24
Withstand voltage at 50 Hz Ud (1 min) [kV] 50 50
Impulse withstand voltage Up [kV] 125 125
Rated frequency fr [Hz] 50-60 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 1600 2000 2500 (2)

www.nepsi.com
16 16 16 16 16
Rated breaking capacity 20 20 20 20 20
(rated short-circuit breaking Isc [kA]
current symmetrical) 25 25 25 25 25
– 31.5 31.5 31.5 31.5
16 16 16 16 16
Rated short-time 20 20 20 20 20
Ik [kA]
withstand current (3s) 25 25 25 25 25
– 31.5 31.5 31.5 31.5
40 40 40 40 40
50 50 50 50 50
Making capacity Ip [kA]
63 63 63 63 63
– 80 80 80 80
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • • •
Opening time [ms] 33 ... 60 33 ... 60
Arcing time [ms] 10 ... 15 10 ... 15
Total breaking time [ms] 43 ... 75 43 ... 75
Closing time [ms] 60 ... 80 60 ... 80
P P H [mm] 794 794 838 838 838
Maximum W [mm] 653 653 853 853 853
overall
H D [mm] 802 802 790 790 790
dimensions
W D Pole distance P [mm] 210 210 275 275 275
Weight [kg] 140 140/146 (3)
228 228 228
TN 7413 7413 7418 7418 7418
Standardised table of dimensions
1VCD – 000173 (3)
– – –
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC: 62271-1 •
(1) Rated current guaranteed with circuit-breaker installed in PowerCube enclosure and with 40 °C ambient temperature.
(2) 2300 A rated uninterrupted current guaranteed with natural ventilation; 2500 A rated current guaranteed with forced ventilation.
(3) 31.5 kA version.

40
Types of withdrawable version circuit-breakers available for PowerCube modules
Complete the circuit-breaker selected with the optional accessories indicated on the following pages.

VD4 withdrawable circuit-breaker (12 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
16 630 VD4/P 12.06.16 p150
20 630 VD4/P 12.06.20 p150
25 630 VD4/P 12.06.25 p150
31.5 630 VD4/P 12.06.32 p150

Provided by Northeast Power Systems, Inc.


16 1250 VD4/P 12.12.16 p150
20 1250 VD4/P 12.12.20 p150
25 1250 VD4/P 12.12.25 p150
31.5 1250 VD4/P 12.12.32 p150
16 630 VD4/W 12.06.16 p210
20 630 VD4/W 12.06.20 p210

www.nepsi.com
25 630 VD4/W 12.06.25 p210
31.5 630 VD4/W 12.06.32 p210
16 1250 VD4/W 12.12.16 p210
20 1250 VD4/W 12.12.20 p210
25 1250 VD4/W 12.12.25 p210
31.5 1250 VD4/W 12.12.32 p210
40 1250 VD4/P 12.12.40 p210
50 1250 VD4/P 12.12.50 p210
20 1600 VD4/P 12.16.20 p210
12
25 1600 VD4/P 12.16.25 p210
31.5 1600 VD4/P 12.16.32 p210
40 1600 VD4/P 12.16.40 p210
50 1600 VD4/P 12.16.50 p210
20 2000 VD4/P 12.20.20 p210
25 2000 VD4/P 12.20.25 p210
31.5 2000 VD4/P 12.20.32 p210
40 2000 VD4/P 12.20.40 p210
50 2000 VD4/P 12.20.50 p210
20 2500 VD4/P 12.25.20 p275
25 2500 VD4/P 12.25.25 p275
31.5 2500 VD4/P 12.25.32 p275
40 2500 VD4/P 12.25.40 p275
50 2500 VD4/P 12.25.50 p275
20 3150 (1) VD4/W 12.32.20 p275
25 3150 (1)
VD4/W 12.32.25 p275
31.5 3150 (1)
VD4/W 12.32.32 p275
40 3150 (1)
VD4/W 12.32.40 p275
50 3150 (1)
VD4/W 12.32.50 p275
W = Width of the switchgear.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.
(1) Up to 4000 A with forced ventilation.

41
2. Selection and ordering
Withdrawable circuit-breakers

VD4 withdrawable circuit-breaker (17.5 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275 Circuit-breaker type
kV kA
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
16 630 VD4/P 17.06.16 p150
20 630 VD4/P 17.06.20 p150
25 630 VD4/P 17.06.25 p150
31.5 630 VD4/P 17.06.32 p150
16 1250 VD4/P 17.12.16 p150
20 1250 VD4/P 17.12.20 p150
25 1250 VD4/P 17.12.25 p150

Provided by Northeast Power Systems, Inc.


31.5 1250 VD4/P 17.12.32 p150
16 630 VD4/W 17.06.16 p210
20 630 VD4/W 17.06.20 p210
25 630 VD4/W 17.06.25 p210
31.5 630 VD4/W 17.06.32 p210
16 1250 VD4/W 17.12.16 p210

www.nepsi.com
20 1250 VD4/W 17.12.20 p210
25 1250 VD4/W 17.12.25 p210
31.5 1250 VD4/W 17.12.32 p210
40 1250 VD4/P 17.12.40 p210
50 1250 VD4/P 17.12.50 p210
20 1600 VD4/P 17.16.20 p210
17,5
25 1600 VD4/P 17.16.25 p210
31.5 1600 VD4/P 17.16.32 p210
40 1600 VD4/P 17.16.40 p210
50 1600 VD4/P 17.16.50 p210
20 2000 VD4/P 17.20.20 p210
25 2000 VD4/P 17.20.25 p210
31.5 2000 VD4/P 17.20.32 p210
40 2000 VD4/P 17.20.40 p210
50 2000 VD4/P 17.20.50 p210
20 2500 VD4/P 17.25.20 p275
25 2500 VD4/P 17.25.25 p275
31.5 2500 VD4/P 17.25.32 p275
40 2500 VD4/P 17.25.40 p275
50 2500 VD4/P 17.25.50 p275
20 3150 (1)
VD4/W 17.32.20 p275
25 3150 (1)
VD4/W 17.32.25 p275
31.5 3150 (1)
VD4/W 17.32.32 p275
40 3150 (1)
VD4/W 17.32.40 p275
50 3150 (1)
VD4/W 17.32.50 p275
W = Width of the switchgear.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.
(1) Up to 4000 A with forced ventilation.

42
VD4 withdrawable circuit-breaker (24 kV)

Ur Isc Rated uninterrupted current (40 °C) [A]


W=800 W=1000
P=210 P=275 Circuit-breaker type
kV kA
u/l=310 u/l=310
ø=35 ø=79
16 630 VD4/P 24.06.16 p210
20 630 VD4/P 24.06.20 p210
25 630 VD4/P 24.06.25 p210
16 1250 VD4/P 24.12.16 p210
20 1250 VD4/P 24.12.20 p210
25 1250 VD4/P 24.12.25 p210
31.5 1250 VD4/P 24.12.32 p210

Provided by Northeast Power Systems, Inc.


16 1600 VD4/P 24.16.16 p275
20 1600 VD4/P 24.16.20 p275
24 25 1600 VD4/P 24.16.25 p275
31.5 1600 VD4/P 24.16.32 p275
16 2000 VD4/P 24.20.16 p275
20 2000 VD4/P 24.20.20 p275

www.nepsi.com
25 2000 VD4/P 24.20.25 p275
31.5 2000 VD4/P 24.20.32 p275
16 2300 (1)
VD4/P 24.25.16 p275
20 2300 (1)
VD4/P 24.25.20 p275
25 2300 (1)
VD4/P 24.25.25 p275
31.5 2300 (1)
VD4/P 24.25.32 p275
W = Width of the switchgear.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.
(1) Up to 2500 A rated current guaranteed with forced ventilation.

Standard fittings of withdrawable circuit-breakers – racking-in/out lever (the quantity must be defined according
for PowerCube modules to the number of pieces of apparatus ordered)
The basic versions of the withdrawable circuit-breakers are – locking electromagnet in the truck. This prevents the
always three-pole and fitted with: circuit-breaker being racked into the panel with the auxiliary
– EL type manual operating mechanism circuits disconnected (plug not inserted in the socket).
– mechanical signalling device for closing springs charged/ – door interlock (compulsory for ABB switchgear); this device
discharged prevents racking the circuit-breaker into the switchgear
– mechanical signalling device for circuit-breaker open/closed when the switchgear door is open.
– closing pushbutton
– opening pushbutton
– operation counter
– set of ten circuit-breaker open/closed auxiliary contacts
Note: with the group of ten auxiliary contacts supplied as standard and the
maximum number of electrical applications, three break contacts (signalling
circuit-breaker open) and four make contacts (signalling circuit-breaker closed)
are available.
– lever for manually charging the closing springs
– isolating contacts
– cord with connector (plug only) for auxiliary circuits, with
striker pin which does not allow the plug to be inserted
into the socket if the rated current of the circuit-breaker is
different from the rated current of the panel

43
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable circuit-breakers for ZS8.4


type switchgear (12 - 17.5 - 24 kV)

Circuit-breaker VD4/Z8
Panel without partitions •

Provided by Northeast Power Systems, Inc.


Panel with partitions —
Preussen Elektra - EON (2)

Width [mm] 650 650 650 650 800 800
Depth [mm] 1000 1000 1000 1000 1200 1200
IEC 62271-100 •
Standards
VDE 0671 •

www.nepsi.com
Rated voltage Ur [kV] 12 12 17.5 17.5 24 24
Rated insulation voltage Us [kV] 12 12 17.5 17.5 24 24
Withstand voltage at 50 Hz Ud (1 min) [kV] 28 28 38 38 50 50
Impulse withstand voltage Up [kV] 75 75 95 95 125 125
Rated frequency fr [Hz] 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 630 1250 630 1250

Rated breaking capacity — — — — 16 16


(rated symmetrical Isc [kA] 20 20 20 20 20 20
short-circuit current) 25 25 25 25 25 25
— — — — 16 16
Rated short-time
Ik [kA] 20 20 20 20 20 20
withstand current(3 s)
25 25 25 25 25 25
— — — — 40 40
Making capacity Ip [kA] 50 50 50 50 50 50
63 63 63 63 63 63
Operation sequence [O-0.3s-CO-15s-CO] •
Opening time [ms] 33...60
Arcing time [ms] 10...15
Total breaking time [ms] 43...75
Closing time [ms] 60...80
P P
H [mm] 579 579 579 579 680 680
Maximum W [mm] 503 503 503 503 653 653
overall
H D [mm] 548 548 548 548 646 646
dimensions
W D Pole distance P [mm] 150 150 150 150 210 210
Weight [kg] 116 116 116 116 140 140
Standardised table of dimensions 1VCD 000092 000137 000137 000137 000089 000138
Operating temperature [°C] – 5 ... + 40
IEC 60068-2-30 •
Tropicalisation
IEC 60721-2-1 •
Electromagnetic compatibility IEC 62271-1 •
(1) Rated current guaranteed with circuit-breaker installed in switchgear with 40 °C ambient temperature.
(2) Special type with device for charging the closing spring by means of a rotary handle outside the operating mechanism.

44
VD4/ZT8 VD4/ZS8
— —

Provided by Northeast Power Systems, Inc.


• —
— •
650 650 650 650 800 800 650 650 800 800
1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
• •
• •

www.nepsi.com
12 12 17.5 17.5 24 24 12 12 24 24
12 12 17.5 17.5 24 24 12 12 24 24
28 28 38 38 50 50 28 28 50 50
75 75 95 95 125 125 75 75 125 125
50-60 50-60
630 1250 630 1250 630 1250 630 1250 630 1250
— — — — 16 16 — — 16 16
20 20 20 20 20 20 20 20 20 20
25 25 25 25 25 25 25 25 25 25
— — — — 16 16 — — 16 16
20 20 20 20 20 20 20 20 20 20
25 25 25 25 25 25 25 25 25 25
— — — — 40 40 — — 40 40
50 50 50 50 50 50 50 50 50 50
63 63 63 63 63 63 63 63 63 63
• •
33...60 40...60
10...15 10...15
43...75 50...75
60...80 60...80
579 579 579 579 680 680 579 579 680 680
503 503 503 503 653 653 503 503 653 653
638 638 638 638 646 646 638 638 646 646
150 150 150 150 210 210 150 150 210 210
116 116 116 116 140 140 116 116 140 140
000093 000134 000134 000134 000090 000136 000091 000133 000088 000135
– 5 ... + 40 – 5 ... + 40
• •
• •
• •

45
2. Selection and ordering
Withdrawable circuit-breakers

VD4/ZS8 - VD4/ZT8 - VD4/Z8 withdrawable circuit-breaker for ZS8.4 switchgear

Ur Isc Rated uninterrupted current (40°C) [A]


Panel without partition Panel with partition Special panel EON
W = 650 W = 800 W = 650 W = 800 W = 650 W = 800
Circuit-breaker type
kV kA P = 150 P = 210 P = 150 P = 210 P = 150 P = 210
u/l = 205 u/l = 310 u/l = 205 u/l = 310 u/l = 205 u/l = 310
ø = 35 ø = 35 ø = 35 ø = 35 ø = 35 ø = 35
20 630 VD4/Z8 12.06.20 p150
25 630 VD4/Z8 12.06.25 p150
20 1250 VD4/Z8 12.12.20 p150
25 1250 VD4/Z8 12.12.25 p150
20 630 VD4/ZT8 12.06.20 p150
25 630 VD4/ZT8 12.06.25 p150

Provided by Northeast Power Systems, Inc.


12
20 1250 VD4/ZT8 12.12.20 p150
25 1250 VD4/ZT8 12.12.25 p150
20 630 VD4/ZS8 12.06.20 p150
25 630 VD4/ZS8 12.06.25 p150
20 1250 VD4/ZS8 12.12.20 p150
25 1250 VD4/ZS8 12.12.25 p150

www.nepsi.com
20 630 VD4/Z8 17.06.20 p150
25 630 VD4/Z8 17.06.25 p150
20 1250 VD4/Z8 17.12.20 p150
25 1250 VD4/Z8 17.12.25 p150
17.5
20 630 VD4/ZT8 17.06.20 p150
25 630 VD4/ZT8 17.06.25 p150
20 1250 VD4/ZT8 17.12.20 p150
25 1250 VD4/ZT8 17.12.25 p150
16 630 VD4/Z8 24.06.16 p210
20 630 VD4/Z8 24.06.20 p210
25 630 VD4/Z8 24.06.25 p210
16 1250 VD4/Z8 24.12.16 p210
20 1250 VD4/Z8 24.12.20 p210
25 1250 VD4/Z8 24.12.25 p210
16 630 VD4/ZT8 24.06.16 p210
20 630 VD4/ZT8 24.06.20 p210
25 630 VD4/ZT8 24.06.25 p210
24
16 1250 VD4/ZT8 24.12.16 p210
20 1250 VD4/ZT8 24.12.20 p210
25 1250 VD4/ZT8 24.12.25 p210
16 630 VD4/ZS8 24.06.16 p210
20 630 VD4/ZS8 24.06.20 p210
25 630 VD4/ZS8 24.06.25 p210
16 1250 VD4/ZS8 24.12.16 p210
20 1250 VD4/ZS8 24.12.20 p210
25 1250 VD4/ZS8 24.12.25 p210
W = Width of the switchgear.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.
ø = Diameter of the isolating contact.

46
Standard fittings of withdrawable circuit-breakers for
ZS8.4 switchgear
The basic versions of the withdrawable circuit-breakers are 3
three-pole and fitted with:
– EL type manual operating mechanism
– mechanical signalling device for closing springs charged/
discharged
– mechanical signalling device for circuit-breaker open/closed
2
– closing pushbutton
– opening pushbutton
– operation counter
– set of ten circuit-breaker open/closed auxiliary contacts
Note: with the group of ten auxiliary contacts supplied as standard and the
maximum number of electrical applications, three break contacts (signalling

Provided by Northeast Power Systems, Inc.


circuit-breaker open) and four make contacts (signalling circuit-breaker
closed) are available. 1
– lever for manually charging the closing springs incorporated
in the operating mechanism for VD4/Z8 and VD4/ZT8,
external with rotary movement for VD4/ZS8
– isolating contacts

www.nepsi.com
– racking in/out lever (the quantity must be defined according
to the number of pieces of apparatus ordered)

VD4/ZS8 (Preussen Elektra-EON version)


– device for closing spring charging, with the door closed,
by means of a removable rotary crank handle outside the
Caption
operating mechanism and the switchgear 1) Spring charging device with rotary crank handle
– Harting 64-pin socket with mechanical interlock which 2) Harting 64 plus socket with mechanical interlock which prevents traverse
when the socket is not inserted
prevents traverse of the circuit-breaker when the plug is not 3) Door - socket - spring charging device interlock (only VD4/ZS8 version)
inserted in the socket
– interlock with the door which prevents the spring charging
lever when the circuit-breaker is closed
– interlock with the door and Harting 64 pin socket which
prevents door closing when the plug is not inserted in the
socket.

VD4/Z8 - VD4/ZT8
– Harting 64-pin socket with mechanical interlock which
prevents traverse of the circuit-breaker when the plug is not
inserted in the socket.

47
2. Selection and ordering
Withdrawable circuit-breakers

Withdrawable circuit-breakers for UniSwitch


switchgear (CBW type unit) and UniMix switchgear
P1/E type unit) (24 kV)

Circuit-breaker VD4/US 24 (3)


VD4/US 24 (4)

UniSwitch (unit CBW type) • • – –

Provided by Northeast Power Systems, Inc.


UniMix (unit P1/E type) – – • •
IEC 62271-100 • • • •
Standards
VDE 0671; CEI EN 62271-100- File 7642 • • • •
Rated voltage Ur [kV] 24 24 24 24
Rated insulation voltage Us [kV] 24 24 24 24
Withstand voltage at 50 Hz Ud (1 min) [kV] 50 50 50 50

www.nepsi.com
Impulse withstand voltage Up [kV] 125 125 125 125
Rated frequency fr [Hz] 50-60 50-60 50-60 50-60
Rated normal current (40 °C) (1)
Ir [A] 630 1250 630 1250
16 (20) (5)
16 (25) (5)
16 16
Rated breaking capacity
Isc [kA] 20 (25) (5)
20 (25) (5)
20 20
(rated symmetrical short-circuit current)
– – 25 25
16 (20) (5)
16 (25) (5)
16 16
Rated short-time
Ik [kA] 20 (25) (5)
20 (25) (5)
20 20
withstand current (3 s) (2)

– – 25 25
40 (50) (5)
40 (50) (5)
40 40
Making capacity Ip [kA] 50 (63) (5)
50 (63) (5)
50 50
— — 63 63
Operation sequence [O - 0.3 s - CO - 15 s - CO] • • • •
Opening time [ms] 33 ... 60 33 ... 60 33 ... 60 33 ... 60
Arcing time [ms] 10 ... 15 10 ... 15 10 ... 15 10 ... 15
Total breaking time [ms] 43 ... 75 43 ... 75 43 ... 75 43 ... 75
Closing time [ms] 60 ... 80 60 ... 80 60 ... 80 60 ... 80
P P
H [mm] 680 680 680 680
Maximum W [mm] 653 653 653 653
overall
H D [mm] 742 742 742 742
dimensions
W D Pole distance P [mm] 210 210 210 210
Weight [kg] 125 125 125 125
Standardised table of dimensions 1VCD 000047 000047 000047 000047
Operating temperature [°C] - 5 ... + 40 - 5 ... + 40 - 5 ... + 40 - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 • • • •
Electromagnetic compatibility IEC 62271 • • • •
(1) Rated current guaranteed with withdrawable circuit-breaker installed in switchgear with 40 °C ambient temperature
(2) The value and duration of the rated short-time withstand current depends on the switchgear. See the specific catalogues of the UniSwitch and UniMix switchgear
(3) The top shutter activation wheels of the UniSwitch switchgear (CBW unit) are mounted and adjusted by the manufacturer of the UniSwitch switchgear
(4) The top shutter activation wheels of the UniMix switchgear (P1/E unit) are available on request
(5) The values in brackets refer to the 12 kV rated voltage.

48
Withdrawable c.-breaker for UniSwitch switchgear (CBW type unit) and UniMix switchgear (P1/E type unit)
Ur Isc Rated uninterrupted current (40 °C) [A]
UniSwitch CBW UniMix P1/E
P=210 P=210 Circuit-breaker type
kV kA
u/l=310 u/l=310
ø=35 ø=79
16 630 (1)
630 VD4/US 24.06.16 p210
20 630 (1)
630 VD4/US 24.06.20 p210
25 — 630 VD4/US 24.06.25 p210
24
16 1250 (1)
1250 VD4/US 24.12.16 p210
20 1250 (1)
1250 VD4/US 24.12.20 p210
25 — 1250 VD4/US 24.12.25 p210
(1) Isc 25 kA at 12 kV.
P = Horizontal centre distance between poles.
u/l = Distance between top and bottom terminal.

Provided by Northeast Power Systems, Inc.


Ø = Diameter of the isolating contacts.

www.nepsi.com
Standard fittings of withdrawable circuit-breakers for
UniSwitch and UniMix switchgear
The basic versions of the withdrawable circuit-breakers are
three-pole and fitted with:
– EL type manual operating mechanism
– mechanical signalling device for closing springs charged/
discharged
– mechanical signalling device for circuit-breaker open/closed
– closing pushbutton
– opening pushbutton
– operation counter
– set of ten circuit-breaker open/closed auxiliary contacts
Note: with the group of ten auxiliary contacts supplied as standard and the
maximum number of electrical applications, three break contacts (signalling
circuit-breaker open) and four make contacts (signalling circuit-breaker closed)
are available.
– lever for manually charging the closing springs
– isolating contacts
– cord with connector (plug only) for auxiliary circuits, with
striker pin which does not allow the plug to be inserted
into the socket if the rated current of the circuit-breaker is
different from the rated current of the panel
– racking-in/out lever (the quantity must be defined according
to the number of pieces of apparatus ordered)
– locking electromagnet in the truck. This prevents the
circuit-breaker being racked into the panel with the auxiliary
circuits disconnected (plug not inserted in the socket).

49
2. Selection and ordering
Withdrawable circuit-breakers

General characteristics of withdrawable


circuit-breakers for UniSec switchgear

Circuit-breaker VD4/SEC
IEC 62271-100 •
Standards

Provided by Northeast Power Systems, Inc.


VDE 0671; CEI EN 62271-100- File 7642 •
Rated voltage Ur [kV] 24
Rated insulation voltage Us [kV] 24
Withstand voltage at 50 Hz Ud (1 min) [kV] 50
Impulse withstand voltage Up [kV] 125
Rated frequency fr [Hz] 50-60

www.nepsi.com
Rated normal current (40 °C) (1)
Ir [A] 630 - 1250
16
Rated breaking capacity
Isc [kA] 20
(rated symmetrical short-circuit current)
25

Rated short-time 16
withstand current (3 s) Ik [kA] 20
25
40
Making capacity Ip [kA] 50
63
Opening time [O - 0.3 s - CO - 15 s - CO] •
Opening time [ms] 33 ... 60
Arcing time [ms] 10 ... 15
Total breaking time [ms] 43 ... 75
Closing time [ms] 60 ... 80
P P
H [mm] 743
W [mm] 653
Maximum overall dimensions H D [mm] 742
W D Pole distance P [mm] 210
Weight [kg] 133
Standardised table of dimensions 1VCD 000190
Operating temperature [°C] - 5 ... + 40
Tropicalization IEC: 60068-2-30, 60721-2-1 •
Electromagnetic compatibility IEC 62271 •
(1) Rated current guaranteed with withdrawable circuit-breaker installed in switchgear with 40 °C ambient temperature.

50
Withdrawable circuit-breaker for UniSec switchgear
Ur Isc Rated uninterrupted current (40 °C) [A]
P=210
kV kA u/l=310 Circuit-breaker type

ø=79
16 630 VD4/SEC 24.06.16 p210
20 630 VD4/SEC 24.06.20 p210
25 630 VD4/SEC 24.06.25 p210
24
16 1250 VD4/SEC 24.12.16 p210
20 1250 VD4/SEC 24.12.20 p210
25 1250 VD4/SEC 24.12.25 p210
P = Horizontal centre distance between poles.
u/l = Distance between top and bottom terminal.
Ø = Diameter of the isolating contacts.

Provided by Northeast Power Systems, Inc.


Standard fittings of withdrawable circuit-breakers for
UniSec
The basic versions of the withdrawable circuit-breakers are

www.nepsi.com
three-pole and fitted with:
– EL type manual operating mechanism
– mechanical signalling device for closing springs charged/
discharged
– mechanical signalling device for circuit-breaker open/closed
– closing pushbutton
– opening pushbutton
– operation counter
– set of ten circuit-breaker open/closed auxiliary contacts
Note: with the group of ten auxiliary contacts supplied as standard and the
maximum number of electrical applications, three break contacts (signalling
circuit-breaker open) and four make contacts (signalling circuit-breaker closed)
are available.
– lever for manual loading of the closing spring built into the
operating mechanism
– isolating contacts
– cord with connector (plug only) for auxiliary circuits, with
striker pin which does not allow the plug to be inserted
into the socket if the rated current of the circuit-breaker is
different from the rated current of the panel
– racking-in/out lever (the quantity must be defined according
to the number of pieces of apparatus ordered)

51
2. Selection and ordering
Optional accessories

The accessories identified with the same number are alternative to each other.

1 Shunt opening release (-MO1) 2 Additional shunt opening release (-MO2)

Provided by Northeast Power Systems, Inc.


www.nepsi.com
This allows remote opening control of the apparatus. The Like the shunt opening release described above, this allows
release can operate both in direct and alternating current. remote opening control of the apparatus and can be supplied
This release is suitable for both instantaneous and permanent by a circuit completely separate from the release (-MO1).
service. In the case of instantaneous service, the minimum It keeps all the electrical and operating characteristics of the
current impulse time must be 100 ms. shunt opening release.
Checking functionality and continuity is only possible Checking functionality and continuity is only possible
using the STU device (accessory 21). using the STU device (accessory 21).

Characteristics
Un 24 - 30 - 48 - 60 - 110 - 125 - 220 - 250 V–
Un 48 - 60 - 110 - 120...127 - 220...240 - V~ 50 Hz
Un 110 - 120 - 127 - 220 - 240 - V~ 60 Hz
Operating limits 70 … 110 % Un
Power on inrush (Ps) DC 200 W; AC = 200 VA
Inrush duration approx. 100 ms
Continuous power (Pc) DC = 5 W; AC = 5 VA
Opening time (1)
40...60 ms
Closing time (2)
40...80 ms
Insulation voltage 2000 V 50 Hz (for 1 min)
(1)
Valid for -MO1 e -MO2.
(2)
Valid for -MC.

52
3 Opening solenoid (-MO3) 4 Shunt closing release (-MC)

Provided by Northeast Power Systems, Inc.


www.nepsi.com
The opening solenoid (-MO3) is a special release with This allows remote closing control of the apparatus.
demagnetisation to be combined with an overcurrent protection The release can operate both in direct and alternating current.
relay of the self-supplied type. This release is suitable both for instantaneous and permanent
It is located in the operating mechanism (in the left side piece) and service.
is not alternative to the additional shunt opening release (-MO2). In the case of instantaneous service, the minimum current
It is not available for 40 and 50 kA circuit-breakers. impulse time must be 100 ms.
Should the application of this accessory be required, specify Use of the permanently supplied release is recommended to carry
the request at the time of order since subsequent application out the electrical anti-pumping function.
by the customer is not possible. It keeps all the electrical and operating characteristics of the
Note: for combination with the protection relays, please ask for the shunt opening release.
document: Data sheet 1VCD600854. Checking functionality and continuity is only possible
using the STU device (accessory 21).

53
2. Selection and ordering
Optional accessories

5 Undervoltage release (-MU) The undervoltage release is available in the following versions:

5A Undervoltage release with power supply branched on the


supply side.

5B Undervoltage release with electronic time delay - KT (0.5


- 1 - 1.5 - 2 - 3s) (power supply branched on the supply
side). This device is set at 0.5s (for adjustment, please
see the Electric Circuit Diagram chapter).

Characteristics
Un 24 - 30 - 48 - 60 - 110 - 125 - 220 - 250 V–
Un 48 - 60 - 110 - 120 - 127 - 220...240 V~ 50 Hz
Un 110 - 120...127 - 220...240 V~ 60 Hz

Provided by Northeast Power Systems, Inc.


– circuit-breaker opening: 35-70% Un
Operating limits
– circuit-breaker closing: 85-110% Un
Power on inrush (Ps) DC 200 W; AC = 200 VA
The undervoltage release opens the circuit-breaker when Inrush duration approx. 100 ms
there is notable lowering or lack of its power supply. It can Continuous power (Pc) DC = 5 W; AC = 5 VA
be used for remote trip (by means of normally closed type

www.nepsi.com
Opening time 60...80 ms
pushbuttons), lock on closing or to control the voltage in the Insulation voltage 2000 V 50 Hz (for 1 min)
auxiliary circuits.
The circuit-breaker can only close with the release supplied
(the closing lock is made mechanically).
The release can operate both in direct and alternating current.

Note
As an alternative to the undervoltage release, an additional
shunt opening release (-MO4) with the same electrical and
operating specifications as shunt opening release (-MO1) can
be installed on request.
Warning! Installation of the additional shunt opening release
(-MO4) requires a special mounting plate for releases.
Moreover, application (-MO4) must be requested at the time
of order and not afterwards.

54
5a Electronic time delay device (-KT) 6 Undervoltage release mechanical override

Provided by Northeast Power Systems, Inc.


The electronic time delay device must be mounted externally This is a mechanical device which allows the undervoltage
in relation to the circuit-breaker. It allows release trip delay release trip to be temporarily excluded.
with established and adjustable times. It is always fitted with electrical signalling.

www.nepsi.com
The use of the undervoltage release is recommended in order Should the application of this accessory be required,
to prevent trips when the power supply network of the release specify the request at the time of order since subsequent
may be subject to cuts or voltage drops of short duration. application by the customer is not possible.
If it is not supplied, circuit-breaker closing is disabled.
The time delay device must be combined with an
undervoltage release for d.c.
Rated voltage of the undervoltage release must be within the
selected range of working of the time-delay device.

Characteristics of the time-delay device


Un 24...30 - 48 - 60 - 110...127 - 220...250 V–
Un 48 - 60 - 110...127 - 220...240 - V~ 50/60 Hz
Adjustable opening time (release + time delay device): 0.5-1-1.5-2-3 sec

55
2. Selection and ordering
Optional accessories

7 Circuit-breaker auxiliary contacts (-BB1; -BB2; -BB3) General characteristics


Insulation voltage according 660 V a.c.
to VDE 0110 standard. Group C 800 V d.c.
Rated voltage 24 V ... 660 V a.c.
Test voltage 2 kV 50 Hz (for 1 min)
Rated overcurrent 10 A
Number of contacts 5
Contact run 6 mm ... 7 mm
Activation force 26 N
Resistance 3 mΩ
Storage temperature –20 °C ... +120 °C
Operating temperature –20 °C ... +70 °C
Contact overtemperature 20 K

Provided by Northeast Power Systems, Inc.


Number of cycles 30.000
Unlimited breaking capacity if used with 10 A fuse in series

Electrical characteristics
Electrical signalling of circuit-breaker open/closed can be Un Rated current Breaking capacity
provided with a set of 15 auxiliary contacts as an alternative 220 V a.c. Cosj = 0.7 2.5 A 25 A
to the 10 provided as standard.

www.nepsi.com
380 V a.c. Cosj = 0.7 1.5 A 15 A
500 V a.c. Cosj = 0.7 1.5 A 15 A
Note 660 V a.c. Cosj = 0.7 1.2 A 12 A
With the group of ten auxiliary contacts supplied as standard 1 ms 10 A 12 A
and the maximum number of electrical applications, three 15 ms 10 A 12 A
24 V d.c.
break contacts (signalling circuit-breaker open) and five make 50 ms 8A 10 A
contacts (signalling circuit-breaker closed) are available. 200 ms 6A 7.7 A
With the group of 15 auxiliary contacts, according to the 1 ms 8A 10 A
electrical applications required, the following are available: 15 ms 6A 8A
60 V d.c.
– for fixed circuit-breakers: thirteen auxiliary contacts, 50 ms 5A 6A
differently divided between break contacts and make 200 ms 4A 5.4 A
contacts according to the figure selected of the electrical 1 ms 6A 8A
diagram; 15 ms 4A 5A
– for withdrawable circuit-breakers, since the plug of the 110 V d.c.
50 ms 2A 4.6 A
auxiliary circuits has a limited number of poles: five break 200 ms 1A 2.2 A
contacts (signalling circuit-breaker open) and five make 1 ms 1.5 A 2A
contacts (signalling circuit-breaker closed). 15 ms 1A 1.4 A
220 V d.c.
50 ms 0.75 A 1.2 A
200 ms 0.5 A 1A

56
8 Transient contact (-BB4) 9 Position contact (-BT3)

Provided by Northeast Power Systems, Inc.


This contact closes momentarily (duration > 30 ms) on circuit- This contact is used, together with the locking magnet in the
breaker opening controlled remotely with a shunt opening operating mechanism (-RL1) to prevent remote closing during
release. traverse into the unit.

www.nepsi.com
The indication is not provided when opening is manual and It is only supplied for the withdrawable version circuit-breakers
local. In fact, a contact (–BB11) is activated by the manual for UniGear ZS1 switchgear and PowerCube modules.
pushbutton and cuts off the transient contact closure (–BB4). It cannot be supplied when the transmitted contacts are
The transient contact is activated directly from the main requested in the truck (-BT1; -BT2).
operating shaft when the indication is provided only on actual
opening of the main circuit-breaker contacts.

10 Transmitted contacts in the truck (-BT1; -BT2)

Transmitted contacts of the withdrawable circuit-breaker


(installed in the circuit-breaker truck - only for VD4/P
withdrawable circuit-breaker).
These contacts are either in addition or as an alternative to
the position contacts (for signalling circuit-breaker racked
out) located in the unit. They also carry out the function of the
position contact (-BT3).

57
2. Selection and ordering
Optional accessories

11 Motor operator (-MS) 12 Contact for signalling closing spring charged/


discharged (-BS2)

Provided by Northeast Power Systems, Inc.


This carries out automatic charging of the circuit-breaker This consists of a microswitch which allows remote signalling
operating mechanism closing spring. After circuit-breaker of the state of the circuit-breaker operating mechanism
closing, the geared motor immediately recharges the closing closing pring.

www.nepsi.com
springs. The following signals are possible:
In the case of a power cut or during maintenance work, – contact open: signalling spring charged
the closing spring can be charged manually in any case – contact closed: signalling spring discharged.
(by means of the special crank handle incorporated in the The two signals must be used for circuits which have the
operating mechanism). same power supply voltage.

Characteristics
Un 24...30 - 48...60 - 110...130 - 220...250 V–
Un 100...130 - 220...250 V~ 50/60 Hz
Operating limits 85 … 110% Un
≤ 40 kA 50 kA (*)
Power on inrush (Ps) DC = 600 W; DC = 900 W;
AC = 600 VA AC = 900 VA
DC = 200 W; DC = 350 W;
Rated power (Pn)
AC = 200 VA AC = 350 VA
Charging time 0,2 s 0,2 s
Charging time 6-7 s 6-7 s
2000 V 50 Hz 2000 V 50 Hz
Insulating voltage
(for 1 min) (for 1 min)
(*) Not available for versions with motorized truck.

58
Protections and locks
Various mechanical and electromechanical locking and protection devices are available.

13 Opening and closing pushbutton protection 14 Opening and closing pushbutton padlock

Provided by Northeast Power Systems, Inc.


www.nepsi.com
The protection only allows the opening and closing The device allows the opening and closing pushbuttons to be
pushbuttons to be operated using a special tool. locked using a maximum of three padlocks (not supplied):
ø 4 mm. Also prevents closing using remote control.
This lock is available in two versions:
14A Possibility of padlocking both the pushbuttons without
distinction
14B Separate padlocking of the opening and/or closing
pushbutton.
N.B. Lock 14A prevents closure by remote control; lock 14B does not prevent
closure by remote control.

59
2. Selection and ordering
Optional accessories

15 Key lock in open position 16 Locking magnet on the operating mechanism (-RL1)

Provided by Northeast Power Systems, Inc.


The lock is activated by a special circular lock. Only allows activation of the command with the electromagnet
Different keys (for a single circuit-breaker) are available, or the supplied.
same keys (for several circuit-breakers).

www.nepsi.com
To activate the lock, keep the opening pushbutton pressed Characteristics
down, turn the key and remove it. 24 - 30 - 48 - 60 - 110 -
Un
With the key removed, the opening pushbutton automatically 132 - 220 - 250 V–
remains in the pressed position preventing local manual 48 - 60 - 110 - 120 ... 127 -
Un
closing and remote electrical closing. 220 ... 240 V~ 50/60 Hz
Operating limits 85 … 110% Un
Power on inrush (Ps) DC 250 W; AC = 250 VA
Continuous power (Pc) DC = 5 W; AC = 5 VA
Inrush duration 150 ms
Insulating voltage 2000 V 50 Hz (for 1 min)

60
17 Locking magnet on the truck (-RL2) 18 Interlock for fixed circuit-breaker

Provided by Northeast Power Systems, Inc.


Compulsory accessory for the withdrawable versions for Device for fixed circuit-breakers which are converted into
UniGear ZS1 switchgear and PowerCube modules, to prevent withdrawable ones by the customer. It allows a mechanical
circuit-breaker racking into the switchgear with the auxiliary lock to be made, by the customer, which prevents racking-

www.nepsi.com
circuit plug disconnected. out/in with the circuit-breaker closed and prevents circuit-
The plug also makes the anti-insertion lock for a different rated breaker closing during translation.
current. Special striker pins do not allow insertion of the plug Note: The device must be requested when ordering since
in the socket if the rated current of the circuit-breaker is lower it must be assembled and tested in the factory.
than the rated current of the panel.
Note: on request, a specific version for the circuit-
breakers for ZS8.4 switchgear is available.

Characteristics
24 - 30 - 48 - 60 - 110 - 125 -
Un
127 - 132 - 220 - 240 V–

24 - 30 - 48 - 60 - 110 - 125 - 127 -


Un
220 - 230 ... 240 V~ 50/60 Hz
Operating limits 85 … 110% Un
Nominal power (Pn) DC 250 W; AC = 250 VA
Continuous power (Pc) DC = 5 W; AC = 5 VA
Inrush duration 150 ms
Insulating voltage 2000 V 50 Hz (for 1 min)

61
2. Selection and ordering
Optional accessories

19 M echanical interlock with the door 20 Motorised truck (-MT)

Provided by Northeast Power Systems, Inc.


This device prevents circuit-breaker racking-in when the It allows racking-in and racking-out of the circuit-breaker in
switchgear door is open. It is only provided for circuit- the switchgear to be carried out remotely, (only for circuit-
breakers used in switchgear UniGear ZS1 and PowerCube breaker in withdrawable version for UniGear ZS1 and ZS8.4

www.nepsi.com
modules, fitted with a special actuator on the door. switchgear and PowerCube modules).

Characteristics
Un 24 - 30 - 48 - 60 - 110 - 220 V–
Operating limits 85 … 110% Un
Nominal power(Pn) 40 W

62
21 STU Shunt Test Unit The control/monitoring Shunt Test Unit allows the continuity
of releases with a rated operating voltage between 24 V and
250 V (AC and DC) to be checked, as well as the functionality
of the electronic circuit of the release.
Checking continuity is carried out cyclically with an interval of
20 seconds between one test and the next.
The unit has optical signals by means of LEDs on the front. In
particular the following information is indicated:
– POWER ON: power supply present
– (-MO) TESTING: test being carried out
– TEST FAILED: signal following a failed test or in the absence
of auxiliary power supply
– ALARM: signal after three failed tests.

Provided by Northeast Power Systems, Inc.


Two relays and a changeover are also available on board the
unit, which allow remote signalling of the following two events:
– failure of a test (resetting is carried out automatically when
Due to the particular construction of these releases, checking the alarm stops)
the functionality of the shunt closing (-MC) and opening – failure of three tests (resetting is only carried out by means
(-MO1, -MO2) releases is not possible with dedicated of the manual - RESET – from the front of the unit).

www.nepsi.com
relays (e.g. TCS Test Control Supervision, CCC Control Coil
Continuity) or with the REF control and protection unit. The There is also a manual - RESET – button on the front of the
only device able to carry out a check of the functionality is the unit.
STU device. Please contact us if you want to carry out this
control with devices other than STU. Characteristics
This device can be combined with the shunt opening release Un 24 ... 250 V AC/DC
(-MO1; -MO2) or with the shunt closing release (-MC) to Maximum interrupted current 6A
check functionality and continuity. Maximum interrupted voltage 250 V AC

63
3. Specific product characteristics

Resistance to vibrations Galvanisation is carried out in accordance with UNI ISO 2081
Standards, classification code Fe/Zn 12, with a thickness of
12x10-6 m, protected by a conversion layer mainly consisting
of chromates in compliance with the UNI ISO 4520 Standard.
These construction characteristics mean that the whole VD4
series of circuit-breakers and its accessories comply with
climate graph 8 of the IEC 60721-2-1 and IEC 60068-2-2
(Test B: Dry Heat / IEC 60068-2-30 (Test Db: Damp Heat,
cyclic) Standards.

Altitude

Provided by Northeast Power Systems, Inc.


The VD4 circuit-breakers are designed to satisfy high levels of
resistance to stresses caused by mechanical vibrations.
Many versions are able to satisfy both the approval criteria of the
major International Shipping Registers (DNV, Lloyd’s Register,

www.nepsi.com
RINA) and the qualification criteria of the International Seismic
Standards (IEEE 344, IEEE 323 and IEC 60980).
For the versions approved by the shipping registers, please
contact us.

Tropicalization The insulating property of air decreases as the altitude


increases, therefore this must always be taken into account
for external insulation of the apparatus (the internal insulation
of the interrupters does not undergo any variations as it is
guaranteed by the vacuum).
The phenomenon must always be taken into consideration
during the design stage of the insulating components of
apparatus to be installed over 1000 m above sea level.
In this case a correction coefficient must be considered,
which can be taken from the graph on the next page, built up
on the basis of the indications in the IEC 62271-1 Standards.
The following example is a clear interpretation of the
indications given above.

VD4 circuit-breakers are manufactured in compliance with


the strictest regulations regarding use in hot-humid-saline
climates.
All the most important metal components are treated against
corrosive factors according to UNI EN 12500 Standards
environmental class C.

64
Graph for determining the Ka correction factor according to the altitude
kA
Example 1,50

• Installation altitude 2000 m


m=1
• Operation at the rated voltage of 12 kV
Ka = e m (H – 1000)/8150
• Withstand voltage at power frequency 28 kV rms 1,40
• Impulse withstand voltage 75 kVp
• Ka factor obtained from graph = 1.13.

Considering the above parameters, the apparatus will have to 1,30

withstand (under test and at zero altitude, i.e. at sea level):


– withstand voltage at power frequency equal to:
28 x 1.13 = 31.6 kVrms

Provided by Northeast Power Systems, Inc.


1,20
– impulse withstand voltage equal to:
75 x 1.13 = 84.7 kVp.

1,10
From the above, it can be deduced that for installations at an altitude
of 2000 m above sea level, with 12 kV service voltage, apparatus
must be provided with 17.5 kV rated voltage, characterised by

www.nepsi.com
insulation levels at power frequency of 38 kVrms with 95 kVp impulse 1,00

withstand voltage. 1000 1500 2000 2500 3000 3500 4000 H

H = altitude in metres;
m = value referred to power frequency and the lightning impulse withstand
voltages and those between phases.

Anti-pumping device
The EL operating mechanism of VD4 circuit-breakers
(in all versions) is fitted with a mechanical anti-pumping
device which prevents re-closing due to either electrical or
mechanical commands.
Should both the closing command and any one of the
opening commands (local or remote) be active at the same
time, there would be a continuous succession of opening and
closing commands.
The anti-pumping device avoids this situation, ensuring
that each closing operation is only followed by an opening
operation and that there is no other closing operation
after this. To obtain a further closing operation, the closing
command must be released and then re-launched.
Furthermore, the anti-pumping device only allows circuit-
breaker closure if the following conditions are present at the
same time:
– operating mechanism spring fully charged
– opening pushbutton and/or shunt opening release
(-MO1/-MO2) not activated
– circuit-breaker open.

65
3. Specific product characteristics

REF 601 protection Device The characteristics of the device are:


- trip precision
- wide adjustment ranges
- single and simultaneous adjustment of the three phases
- no limitation (due to the current sensors) to the rated
breaking capacity and at the short-time withstand current of
the circuit-breaker
- pushbuttons for local electrical operation of the circuit-
breaker (opening and closing pushbutton
- 5 distinct indicators: “relay in operation”, “relay in trip
threshold”, “relay tripped”, “relay tripped due to exceeding
phase current”, “relay tripped due to exceeding ground fault
current”
- interface consisting of an LCD display and of “arrow”

Provided by Northeast Power Systems, Inc.


keys, “enter” and “esc” for easier navigation inside the
“measurement”, “data recording”, “event recording”,
“settings”, “configuration” and “test” menus
- three user levels: “operator” (only display, with free
access, by keeping this key pressed for at least 5 sec.),
“configurator” (like the previous one, but also with

www.nepsi.com
permission to set the protection parameters, i.e. times and
On request, the REF 601 switchgear protection device is thresholds, and communication, if present - access limited
available for protection of the installations, which requires an by a password), “administrator” (like the previous ones, but
auxiliary power supply for its operation unlike the previous also with permission to set the password and configure the
PR512 which was a self-supplied release. basic settings of the device, such as the rated current -
The REF 601 has protections and trip curves in accordance access limited by a password)
with the IEC 255-3 Standard. It sees to the protection function - continual display of the current on the most highly loaded
against overload (51), against instantaneous and delayed phase and of the round current
short-circuit (50-51) and against instantaneous and delayed - recording of the value of the currents which caused the
homopolar ground fault (50N and 51N). It also detects the device to trip
second harmonic component to prevent unwarranted tripping - storage of the number of openings carried out by the device
on connection of a transformer (68). - event log (storage of the parameters described above in the
last 5 trips of the device) in a non-volatile memory
The unit has 3 inputs from current sensors of the type with - curves “ß = 1” or “ß = 5” and curve “RI” specific for the
Rogowsky coil, one input from external toroidal CT and from Belgian market (only REF 601 IEC)
the keyboard 4 rated currents can be set: 40, 80, 250 and - circuit-breaker opening by means of an undervoltage
1250 A. release (only REF 601 CEI)
If the unit is connected to 3 current sensors, the 50N and 51N - version, on request, with RS485 4-wire serial
protection functions are carried out with the vectorial sum of communication
the phase currents; if only 2 current sensors are used, then - MODBUS RTU full duplex protocol
the external toroidal current transformer must be provided for - multi-voltage feeder 24 … 240 V a.c.- d.c
functions 50N and 51N.
The external toroidal current transformer can be with
openable core or closed and with any transformation ratio as
long with a 1 A secondary current.
The ABB current sensors of the type with Rogowsky coil
provided for REF 601, are only suitable for installation on MV
insulated cables.

66
Environmental protection programme Spare parts
VD4 circuit-breakers are manufactured in accordance with – Shunt opening release
the ISO 14000 Standards (Guidelines for environmental – Additional shunt opening release
management). – Undervoltage release
The production processes are carried out in compliance – Time delay device for undervoltage release
with the Standards for environmental protection in terms of – Shunt closing release
reduction in energy consumption as well as in raw materials – Spring charging geared motor with electrical signalling of
and production of waste materials. All this is thanks to spring charged
the medium voltage apparatus manufacturing facility – Contact signalling geared motor protection circuit-breaker
environmental management system. open/closed
Assessment of the environmental impact of the life cycle of – Contact signalling closing spring charged/discharged
the product, obtained by minimising energy consumption – Transient contact with momentary closing during circuit-
and overall raw materials of the product, became a concrete breaker opening

Provided by Northeast Power Systems, Inc.


matter during the design stage by means of targeted selection – Circuit-breaker auxiliary contacts
of the materials, processes and packing. – Locking electromagnet on the operating mechanism
This is to allow maximum recycling at the end of the useful life – Position contact of the withdrawable truck
cycle of the apparatus. – Contacts signalling connected/isolated
– Opening solenoid
– Key lock in open position

www.nepsi.com
– Isolation interlock with the door
– Protection for opening pushbutton
– Protection for closing pushbutton
– Locking electromagnet on the withdrawable truck
– Set of six isolating contacts.

Ordering
For availability and to order spare parts, please contact our
Service department, specifying the circuit-breaker serial
number.

67
4. Overall dimensions

Fixed circuit-breakers

450
VD4 95
248
TN 1VCD000050
12 kV 32
Ur A
17.5 kV
20 20
Ir 1600 A 2XM10 PROF.20

310
20 kA 4XM12 PROF.25

Isc 25 kA

599

12
31.5 kA

20
475
56 31
435

20
16

12
237.5
14
170

77.5
97

56
236 28
DETAIL A
49 28 345* 44* SCALE 1 : 2 . 5
25 400 250
45 114 12
150 150 409
424

Provided by Northeast Power Systems, Inc.


160
12
22

www.nepsi.com
(*) Fixing interchangeability with previous series (345 x 400).

Fixed circuit-breakers
450
VD4 45
248 32
95 2xM10 PROF.18
TN 7405 M12 PROF.25
12 kV
Ur A
17.5 kV
630 A
22

Ir 115
205

1250 A
31

16 kA
435

475
461
16
56

20 kA
Isc 22
25 kA
217.5
170

31.5 kA
77.5

DETAIL A
56

SCALE 1:2
236 28
345* 44*
49 28

25 400 45 250 114 12

409

150 150 424


160
22

12

(*) Fixing interchangeability with previous series (345 x 400).

68
Fixed circuit-breakers

570
VD4
32 45
TN 7406 308
95
2XM10 PROF.20

12 kV M12 PROF. 25
Ur
17.5 kV A

630 A

22
Ir 115

205
1250 A
31

16 kA

461

475
435
56
16

20 kA 22
Isc
25 kA
170

217.5
31.5 kA DETAIL A

77.5
SCALE 1:2

24
296 28
345 * 44 *
49 28

25 520 45 250 114 12


409
210 210 424
160

Provided by Northeast Power Systems, Inc.


22

12

www.nepsi.com
(*) Fixing interchangeability with previous series (345 x 520).

Fixed circuit-breakers

570
VD4 95
308
TN 1VCD003282 11 11

12 kV
Ur

11
17.5 kV M12x25 deep

1250 A
Ir eep
x18 d
310

M10

11
1600 A
A
Isc 40 kA
30

589
16

475
435

56

A (1:4)
238
171

77.5
24

296 28
345 * 44 *
49 28
45 250 114
520
409
210 210
422 12
160
26

12

(*) Fixing interchangeability with previous series (345 x 650).

69
4. Overall dimensions

Fixed circuit-breakers

700
VD4 11 11
95
TN 1VCD003285 373 M12x25 deep

M10x18 deep

11
12 kV
Ur A
17.5 kV
1250 A
Ir

310
1600 A

11
Isc 40 kA
30

589
16
435

475
56

238

24
171

77.5
36 28 45 250 114
361 49 28 345 * 44

25 650 422 12

275 275
213

Provided by Northeast Power Systems, Inc.


22

12

www.nepsi.com
(*) Fixing interchangeability with previous series (345 x 650).

Fixed circuit-breakers
700
VD4
373 95 45
TN 1VCD000051 2XM 10 PROF. 18
32 M12 PROF. 25
12 kV
Ur A
17.5 kV
22
205

630 A 115
Ir
1250 A
475
56 31

461

22
435

16

16 kA
14

217.5
77.5

20 kA
24

DETAIL A
170

Isc SCALE 1 : 2
97

25 kA
31.5 kA 236 28
345 * 44 *
49 28
45 250 114 12
25 650
409
424
275 275
213
12
22

(*) Fixing interchangeability with previous series (345 x 650).

70
Fixed circuit-breakers

VD4 700 1600-2000A 2500A


95
TN 7408 373 95

12 kV 32
A
Ur
17.5 kV
1600 A

310
Ir 2000 A
2500 A
31

599

616
20 kA

475
435
56

16

Isc 25 kA

237
31.5 kA
170

78
VD4

24
361 28 345 * 44 *
TN 7408 49 28 45 250 114
20 20
12 kV 25 650 409 12
Ur 2XM10 PROF.20
17.5 kV 424

20
275 275

12
2000 A
Ir 213
2500 A

Provided by Northeast Power Systems, Inc.


12
Isc 40 kA

20
4XM12 PROF.25

DETAIL A
SCALE 1:2
12
22

www.nepsi.com
(*) Fixing interchangeability with previous series (345 x 650).

Fixed circuit-breakers

VD4 570 1600-2000A 2500A


95 95
TN 7407 308

Ur 12 kV A

Ir 2500 A 32

20 kA
310

25 kA
Isc
599

31.5 kA
31

616

40 kA
435

475
56

16

237.5

VD4
170

77.5

TN 7407
Ur 12-17.5 kV 296 28
24

345 * 44 *
1600 A 49 28
45 250
Ir
2000 A 25 520 409 12 2XM10 deep 20

20 kA 424 20 20
210 210
25 kA 4XM12 deep 25
Isc 160
31.5 kA
20
12

40 kA
12

20

DETAIL A
SCALE 1:2
22
12

(*) Fixing interchangeability with previous series (345 x 650).

71
4. Overall dimensions

Fixed circuit-breakers

373 424
VD4
20 20
95 307
TN 1VCD000149
12 kV
Ur

20
17.5 kV

12
32
3150 A
Ir
4000 A (**)

12
310

20
20 kA A

635
30

25 kA
435

474

2x
5
Isc 31.5 kA

th 2

M1
0
dep
56

40 kA

de
16

237

pth
A (1:4)

12
171

50 kA

4xM
2.5

20
24
77.5
28
142
25 49
345* 44*
361 28
45 250 114
650

700 409

275 275
213

Provided by Northeast Power Systems, Inc.


22

12

www.nepsi.com
(*) Fixing interchangeability with previous series (345 x 650).
(**) With forced ventilation.

Fixed circuit-breakers

600
VD4
323 4xM12 deep 25
459
TN 1VCD003440 300 130
2xM10 deep 20
12 kV

20
Ur
12

17.5 kV 74

1250 A
12

32 20

20
20
Ir 1600 A
310

2000 A
610
30

Isc 50 kA
16

475
435
56

237
171

24
77.5

2.5

156
135 116 28 31 172 142
2.5

40 165 28 404
520 428

210 210
22

12

72
Fixed circuit-breakers

750 459
VD4 4xM12 deep 25
398
130
TN 1VCD003441 375 2xM10 deep 20

20
12 kV

12
Ur 74
17.5 kV
20

12
32

20
1250 A 20

310
1600 A
Ir

610
2000 A
30
16

2500 A

475
435

Isc 50 kA
56

237

24
171

24
78
135 116 28
2.5

2.5
165 28 69.5 270 64.7 225

30.5 689
404 24
31 428
275 275

Provided by Northeast Power Systems, Inc.


www.nepsi.com
22

12

Fixed circuit-breakers

750 459
VD4 4xM12 deep 25
398 240 2xM10 deep 20
189
TN 1VCD003443 189
375 130
12 kV

20
Ur
12
118

17.5 kV 74

Ir 3150 A (*) 32

20
12

20
Isc 50 kA 20
310
636
30

16

475
435
56

237
171

24
24

2.5

135 172
2.5

116 28
69.5 270 64.5 225
30.5 165 28
404 24
689 31 428

275 275
12
22

12

(*) 4000 A with forced ventilation.

73
4. Overall dimensions

Fixed circuit-breakers

570
VD4 95
308
TN 7409 45
A
Ur 24 kV 32 2XM10 PROF.20
M12 PROF.25
630 A
Ir
1250 A

310

22
115
16 kA
22
Isc 20 kA

631
31

25 kA 22

475
435
56
16

282.5
170

DETAIL A

77.5
SCALE 1:2

24
296 28 M12 345* 39*
49 28 45 250 114 12
25 520 409
424

210 210
160

Provided by Northeast Power Systems, Inc.


www.nepsi.com
(*) Fixing interchangeability with previous series (345 x 520).

Fixed circuit-breakers

700
VD4 95 22
373 2XM10 PROF.18 M12 PROF.25
TN 7410
A
Ur 24 kV
32
630 A
22

Ir
1250 A
310

115
16 kA
45
Isc 20 kA
631
31

25 kA
475
435

16

282.5
56

170

77.5

DETAIL A
361 28 345 * 44 * SCALE 1:2
24

49 28 45 250 114 12
25 650 409
424
275 275
213
22

12

(*) Fixing interchangeability with previous series (345 x 650).

74
Fixed circuit-breakers

VD4 700 1600-200A 2500A


373 95
TN 7411 95

Ur 24 kV
1600 A
Ir 2000 A

310
2500 A
16 kA

661
647
20 kA
31

16

Isc
25 kA

475
435

31,5 kA

282.5
56

170

361 28 345 * 44 *

24
77.5
45 250 114
49 28
409
25 650 424
20 20
275 275

213 2XM10 DEEP 20

Provided by Northeast Power Systems, Inc.


20
12
12

20
4XM12 DEEP 25
22

www.nepsi.com
DETAIL A
SCALE 1:2

(*) Fixing interchangeability with previous series (345 x 650).

Fixed circuit-breakers

570
VD4 95 85
308
TN 1VCD000172
4XM12 DEEP25 2XM10 DEEP 20
Ur 24 kV
40
Ir 1250 A
32
Isc 31.5 kA
310

12

72
22
647

12
31

475
435

16
56

282.5

77.5

72
17 0

DETAIL A
24

SCALE 1 : 2
296 28
M12 45 250 114
49 28
344.5 * 39*
25 520
409
210 210
424
160
22

75
4. Overall dimensions

Fixed circuit-breakers
784
VD4
TN 1VYN300901-LT
Ur 36 kV
1250 A 245
R16

328
Ir 1600 A
2000 A
Isc 31.5 kA
31.17
57.9

876

612
571

482.5
15.5

305

28
49

104.5

87.5
28

786
331
275 275
447

Provided by Northeast Power Systems, Inc.


470 22
478.5

www.nepsi.com

76
Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules
492 630A 1250A
VD4/P 234 42.5
36 124
121
TN 7412 49 28
36 28 62.5 15
12 kV
Ur
17.5 kV 303

10
630 A
Ir

91

79

98
1250 A
16 kA

205

35
35
624.5

31
618

20 kA

628
Isc
16

25 kA
56

71 38

31.5 kA

260
213

154
19

76
340

19.5

18
4
503 14 25 320

24
531
370
501 383
490
416 53
456
150 150 438
662

Provided by Northeast Power Systems, Inc.


55
609

www.nepsi.com
124

121
38
48

Withdrawable circuit-breakers for PowerCube modules


636
VD4/W 44 230 119
111
TN 7420 49 28

8
62.5

12 kV 36 28
Ur
17.5 kV
630 A 36
35

Ir
1250 A
310

16 kA 303
691
688
31

691

688

Isc 25 kA
16

31.5 kA
71 38
56

280
213

165

76

18

653 14 25 320
21.5

19.5
4

650 359.5
640 370
626 383
550 416 53
642

210 210
55
589

119

111
48

38

77
4. Overall dimensions

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules

VD4/P 636 125


44 230 111 17
TN 1VCD003284 49 28 62.5

8
12 kV 36 28
Ur
17.5 kV
1250 A 37
Ir
1600 A

310
Isc 40 kA

688
30
688
691

303
16

79
71 38
56

280
214

165

76

21.5
4

19.5

18
4
653 14 320
25
650 359.5
640 370
626 383
552
416 53
210 210
640

Provided by Northeast Power Systems, Inc.


55
587

640

www.nepsi.com
53

38

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules

842
VD4/P
144 230 119
TN 1VCD003286 49 28
111 17
122

36 28

8
12 kV
Ur
17.5 kV
1250 A
Ir 303
37
1600 A
310

Isc 40 kA
691

688

30

16

688
79

71 38
56

280
213

165

76

19.5

25 320
21.5
4

853 14
4

359.5
850
370
836
383
806
416 53
750
640
275 275
55
587
53

38

78
Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules

VD4/P 636 119


44 230 111 17
TN 7415 49 28 62.5

122

8
12 kV 36 28
Ur
17.5 kV
1600 A 36 303
Ir

310
2000 A

79
20 kA

688
691
688
31

Isc 25 kA
16

71 38
31.5 kA
56

280
213

165
VD4/P

76
TN 7415 653 14
4

25 320

19.5
21.5
4
12 kV 650
359.5
Ur 370
17.5 kV 640 383
Ir 2000 A 626 416 53
550 640
Isc 40 kA 210 210

Provided by Northeast Power Systems, Inc.


55
587
119

111

www.nepsi.com
53
38

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules

842
VD4/P 119
144 230
TN 7416 110
49 28
122

62.5

8
12 kV 36 28
Ur
17.5 kV
1600 A 36
303
Ir
2000 A
310

79

688

20 kA
31
691

688

Isc 25 kA
71 38
56
16

31.5 kA
280
213

165

VD4/P
76

TN 7416
Ø19.5
21.5
4

853 14 25 320
359.5
12 kV
Ur 850 370
17.5 kV 836 34 383
806 416 53
Ir 2000 A 640
750
Isc 40 kA 275 275
55
587

119

111
53

38

79
4. Overall dimensions

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules


842
VD4/P 144 230
119

TN 7417 49 28 111 17

152
36 28 62.5
12 kV

8
Ur
17.5 kV
Ir 2500 A 303

109
20 kA 36

310
25 kA
Isc
31
691
688

16

688
31.5 kA
40 kA
56

71 38

280
213

165
76

19.5
25 320

21.5
853 14
4

4
359.5
850
370
836
383
806
416 53
750
640

Provided by Northeast Power Systems, Inc.


275 275
587

55
119

111

www.nepsi.com
53

38

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules

VD4/P 636
44 220 25 119
TN 1VCD003444 165 28
111 16

10
12 kV 135 116 28
Ur
17.5 kV
122

1250 A
36 433
Ir 1600 A
20
310

2000 A
79
30
16
688

Isc 50 kA
691

688
478
56

26
280

19.5
213

165
19

76

21.5
12

605
4

25
4

4
14 653 14 320
370
650
359.5 49.5
640
34 383
626
416 53
550
590

210 210
29
590

360

303
4

12
23

80
Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules
842
VD4/P
144 217.5 25 119
TN 1VCD003445 111 16
165 28
12 kV
Ur 135 116 28

10
17.5 kV

122
1600 A 433
Ir 36
2000 A

310
20
Isc 50 kA

79

688
691
688

30

16

478
56

26

280
213

165
19

76
25 4

19.5
805

4
21.5
12
4

320
14 853 14
370
850 359.5 49.5
836 34 383
806 416 53
750 590

Provided by Northeast Power Systems, Inc.


275 275
29
590

360

303
4

www.nepsi.com
22

12

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules

VD4/P 842
143 217.5 119
25
TN 1VCD003446 111 16
164 28
12 kV
Ur 136 115 28

10
17.5 kV
152

Ir 2500 A
36
Isc 50 kA 20
310

433
109
688
30

691

688
16

478
56

280

19.5

26
213

165
19
12

76

25
21.5

805
4

320
14 853 14 370
850 359.5 49.5
836 34 383
812 417
750 590

275 275
29
590
360

303
4

12
22

81
4. Overall dimensions

Withdrawable circuit-breakers for PowerCube modules


842
VD4/W 361 25
119
TN 1VCD003596 129 30 240 111 16

10
12 kV 165 28
130
Ur
17.5 kV 135 116 28

118
152
Ir 3150 A (*)
Isc 50 kA
36
20

310
433

742

109
742
730

732
678
30

16

478
56

280
26
213

19,5
165
19

76
805 25 4

21,5
4

12

4
14 853 320
850 370
836 359,5 49,5
806 34 383
416,5 53
750 590

Provided by Northeast Power Systems, Inc.


275 275
29

189
590
360

303

www.nepsi.com
4

(*) 4000 A with forced ventilation.


12
22

Withdrawable circuit-breakers for UniGear ZS1 switchgear


842
VD4/P 361 25
240 111 16

10
TN 1VCD003447 165 28
130
12 kV 135 116 28
Ur
17.5 kV
118
152

Ir 3150 A (*)
20
Isc 50 kA 36
433
310

109
730

742
678

733
30

16

478
56

280

26
213

19.5
165
19

76

805 25 4
21.5
4
12

14 853
4

320
850 370
836
359.5 49.5
806
34 383
416 53
750 590
275 275
29

189
589
360

303
4

12
22

(*) 4000 A with forced ventilation.

82
Withdrawable circuit-breakers for UniGear ZS1 switchgear
842 111 17
VD4/P 373.5
17kV 93

10
49 12kV
TN 1VCD000153
28
12 kV

2
36 86
Ur
17.5 kV

166
149
Ir 3150 A (*) 52

20 kA

310
25 kA
730

30

732
Isc
31.5 kA

109
16

40 kA

280
56
214

165
19

76
356

19.5
21.5
303 53
4

4
853 14
25 320
850
836 360
806 370
750
34 382
275 275
416
640

Provided by Northeast Power Systems, Inc.


16
8
55
587

www.nepsi.com
4
96

(*) 4000 A with forced ventilation. 189


12
22
39

Withdrawable circuit-breakers for UniGear ZS1 switchgear and PowerCube modules


636 630A 1250A
VD4/P 119 23
20

44 232 19
TN 7413
Ur 24 kV 49 28
36 28
630 A
Ir
1250 A
48
16 kA
310

770

Isc 20 kA
775
770
31

25 kA
16

71 38
56

325
213

197

72

653 13.5 25 320


4

650 370
641 383
610 458

210 210 303 53

800
98
79
79

36
747

55

35
35
19

119

83
4. Overall dimensions

Withdrawable circuit-breakers for UniGear ZS1 switchgear

842 630A 1250A


VD4/P 119 23
144 232 19
TN 7414
Ur 24 kV

20
49 28
630 A 36 28
Ir
1250 A 48

310
16 kA

790
775
770

7
Isc 20 kA
31

3
16

25 kA
56

71 38

325
5

197
213

72
25 320
4

4
853 14 370
383
850
458
836
303 53
805
800

275 275

Provided by Northeast Power Systems, Inc.


79

98

79
747

35
35

36
55
19

119

www.nepsi.com
53

Withdrawable circuit-breakers for UniGear ZS1 switchgear


842 1600-2000A 2500A
VD4/P 119
141 233
TN 7418
Ur 24 kV
20

49 30
36 28
1600 A
Ir 2000 A
2500 A
310

(1)
834

16 kA
31
810
817

16

20 kA
Isc
25 kA
345
56

31.5 kA
233

197

72

25 320
4

853 14
4

370
850 383 46
836 303 53

805 458
785

275 275
132
732

79
55
119
52

(1) The rated uninterrupted current of 2300 A is guaranteed with natural ventilation. The rated uninterrupted current of 2500 A is guaranteed with forced ventilation.

84
Withdrawable circuit-breakers for UniGear ZS1 switchgear

636
VD4/P 119 23
44 232 19
TN 1VCD000173

20
Ur 24 kV
1250 A

79
Ir 49 28

Isc 31.5 kA 36 28 48

310
35
775

770

770
71

56 31
16

326
213

197
72
4

4
653 13.5 25 320
303 53

650 370

641 383

610 458
800

210 210

Provided by Northeast Power Systems, Inc.


747

55
119
19

www.nepsi.com
Withdrawable circuit-breakers for UniGear ZS1 switchgear

842
VD4/P
141 233
TN 1VCD000177
Ur 24 kV 49 28
2700 A 36 28
166

Ir
3150 A
310

Isc 31.5 kA
109

834
817

810

31
16
56

345
233

25 320 46
4

853 14
4

370
850
383
836 303
805 458 53
787

275 275
734

55
119
52

85
4. Overall dimensions

Withdrawable circuit-breakers for PowerCube modules

842
VD4/W 125 17
144 230
111
TN 1VCD000152

10
49 92
12kV 17kV
12 kV 28
86
Ur 36
17.5 kV

149

166
Ir 3150 A (*) 52

20 kA

310
730

25 kA
30

Isc

742
31.5 kA

109
16

40 kA

280
56
214

165
19

76
356

19.5
303 53
4

853 14
25 320
850
360
836
370
806
34 382
750
275 275 416
640

16

Provided by Northeast Power Systems, Inc.


8
29

55
587
302
94
4

www.nepsi.com
189
38

12
22

(*) 4000 A with forced ventilation.

86
Withdrawable circuit-breakers for ZS8.4 switchgear

VD4/Z8 531 303 52


TN 1VCD000092

91
Ur 12 kV
Ir 630 A
20 kA
Isc
25 kA

205
35

563
510

260
4
503 53
548

150 150

Provided by Northeast Power Systems, Inc.


55
495

www.nepsi.com
Withdrawable circuit-breakers for ZS8.4 switchgear
531 303 52
VD4/ZT8
486
TN 1VCD000093 455
91

Ur 12 kV
Ir 630 A
20 kA
Isc
205

25 kA
35

563
510

260

153

503 195
4

486 380 53
150 150 640
55
584

87
4. Overall dimensions

Withdrawable circuit-breakers for ZS8.4 switchgear

VD4/ZS8 531 303 52


486
TN 1VCD000091
455

91
Ur 12 kV
Ir 630 A

5
20 kA
Isc

205
25 kA

35

563
524
510

260

153
86

69

4
195
503
486 380 53
150 150 640

Provided by Northeast Power Systems, Inc.


55
584

www.nepsi.com
67

Withdrawable circuit-breakers for ZS8.4 switchgear


531 303 52
VD4/ZS8 486
TN 1VCD000133 455

Ur 12 kV

5
Ir 1250 A
20 kA
Isc
98
205

35

25 kA
563
524
514
260

153
86

69 195
4

503 380 53
486 637
150 150
55
583
67

88
Withdrawable circuit-breakers for ZS8.4 switchgear

VD4/Z8 531 303 52


TN 1VCD000137
12 kV
Ur
17.5 kV
630 A

205
Ir

84
35
1250 A
20 kA

563
507
Isc
25 kA

260
503
53

150 150

Provided by Northeast Power Systems, Inc.


55
495

www.nepsi.com
Withdrawable circuit-breakers for ZS8.4 switchgear
530
VD4/ZT8
486 303 52
TN 1VCD000134 455
12 kV
Ur
17.5 kV
630 A
Ir
205

1250 A
98
35

20 kA 563
Isc
514

25 kA
260

153

503 195
4

486 383 53
150 150 637
55
583

89
4. Overall dimensions

Withdrawable circuit-breakers for ZS8.4 switchgear


681
VD4/ZS8 3 303 52
636
TN 1VCD000088

91
Ur 24 kV 611
Ir 630 A
16 kA

310
Isc 20 kA

35

680
25 kA

563
524
325
86

69

4
653 195
636 380 53
640
210 210

Provided by Northeast Power Systems, Inc.


55
583

www.nepsi.com
67

Withdrawable circuit-breakers for ZS8.4 switchgear

VD4/Z8 681 3 303 52


TN 1VCD000089
91

Ur 24 kV
Ir 630 A
16 kA
310

Isc 20 kA
35

25 kA
680
563
325

653
4

53
210 210 640
55
583

90
Withdrawable circuit-breakers for ZS8.4 switchgear
681 303 52
VD4/Z8
TN 1VCD000138
Ur 24 kV
Ir 1250 A
16 kA

310

84
Isc 20 kA

35
25 kA

677

563
325
653 53

4
210 210 640

Provided by Northeast Power Systems, Inc.


55
587

www.nepsi.com
Withdrawable circuit-breakers for ZS8.4 switchgear
681 3 303 52
VD4/ZT8
636
TN 1VCD000090
Ur 24 kV
611
Ir 630 A
16 kA
310

Isc 20 kA
35

25 kA 680
563
325

653 195
4

636
380 53
210 210
640
55
585

91
4. Overall dimensions

Withdrawable circuit-breakers for ZS8.4 switchgear


681
VD4/ZT8 303 52
636
TN 1VCD000136
Ur 24 kV
611
Ir 1250 A
16 kA

310
Isc 20 kA

84
35
25 kA

677

563
325
653

4
195
636
210 210 380 53

640

Provided by Northeast Power Systems, Inc.


55
587

www.nepsi.com
Withdrawable circuit-breakers for ZS8.4 switchgear
681
VD4/ZS8 636 303 52
TN 1VCD000135
Ur 24 kV 611
Ir 1250 A
16 kA
310

Isc 20 kA
84
35

25 kA
677

563
524
325
86

69
4

195
653
636 380 53

640
210 210
55
587
67

92
Withdrawable circuit-breakers for UniSwitch and UniMix switchgear

VD4/US 626 630A 1250A


570 121
TN 1VCD000047
Ur 24 kV
630 A
Ir
1250 A

310
16 kA A

35
35
Isc 20 kA
48
25 kA

435,5
38

325
653 13,5 25 320

4
650 370 23
383

36.3
210 210 303 53
742

Provided by Northeast Power Systems, Inc.


DETAIL A
SCALE 1 : 2
55

www.nepsi.com
Withdrawable circuit-breakers for UniSec switchgear
626±1 630A 121±1 1250A
VD4/SEC 604 149 41
TN 1VCD000190
79

3
45°

Ur 24 kV
630 A
Ir
1250 A
310±1

16 kA
Isc 20 kA A
35

35

42
739

25 kA
435±1

38
325±1

18

653 14 25 320
4

650 370 23
383
36.3

303
210±1 210±1 415
648 ±1.5 53
DETAIL A
742
SCALE 1 : 2
55

93
4. Overall dimensions

Withdrawable circuit-breakers for UniGear ZS2 switchgear and PowerCube modules (36 kV)
842
VD4
TN 1VYN300901-KG
Ur 36 kV
Ø "A"
1250 A
Ir 1600 A 776

380
2000 A
Isc 31.5 kA

953
956

973
480

125
198

Provided by Northeast Power Systems, Inc.


853 4 4
880 460 53

736

275 275

www.nepsi.com
736

Breaker type Ø A mm
VD4 36.12.32 35
VD4 36.16.32 - VD4 36.20.32 79

94
5. Electric circuit diagram

State of operation represented


The diagrams shows the following conditions:
– Circuit-breaker open and connected (only withdrawable circuit-breaker)
– Circuits de-energized
– Closing springs discharged

Graphical symbols for electric diagrams

Thermal effect Mass, frame Capacitor (general Passing make contact


symbol) closing momentarily

Provided by Northeast Power Systems, Inc.


during release

Electromagnetic effect Conductors in shielded Motor Closing position contact


cable (two conductors (general symbol) (limit switch)
shown)

www.nepsi.com
Timing Connection of Opening position
Rectifier with two
conductors contact (limit switch)
half-waves (bridge)

Pushbutton control Terminal or clamp Make contact Power circuit-breaker


with automatic opening

Key control Socket and plug Break contact Control coil


(female and male) (general symbol)

Earth Resistor Change-over break Lamp


(general symbol) (general symbol) before make contact (general symbol)

95
5. Electric circuit diagram

Electric circuit diagram of fixed circuit-breakers 1VCD 400046


The electric circuit diagram given in this section regards the fixed circuit-breakers with breaking capacity up to 40 kA.

Provided by Northeast Power Systems, Inc.


www.nepsi.com

96
Provided by Northeast Power Systems, Inc.
www.nepsi.com

97
Provided by Northeast Power Systems, Inc.
www.nepsi.com
5. Electric circuit diagram

98
Caption Description of figures
= Reference number of diagram figure. Fig. 1 = Motor circuit for closing spring charging (see note
* = See the note indicated by the letter. C).
-BB1,..2-3 = Circuit-breaker auxiliary contacts. Fig. 2 = Shunt closing release (anti-pumping is carried out
-BB4 = Circuit-breaker auxiliary passing contact with mechanically) (see note D).
momentary closing during opening. Fig. 3 = Locking magnet. When de-energised, it
-BB6 = Contact for the undervoltage release de- mechanically prevents circuit-breaker closing. It
energized electrical signal is possible to limit consumption by connecting
-BB11 = Contact to interrupt the –BB4 signal during the a delay pushbutton in series to enable the
manual opening operation operation.
-BM = STU Test unit for supervision of shunt opening Fig. 5 = Instantaneous undervoltage release (see note B).
release and shunt closing release winding Fig. 6 = Circuit of third opening release with continuous
continuity (see note D). control of the winding (see note D).
-BS1 = Spring-charging motor limit contacts. Fig. 7 = Circuit of the first shunt opening release with

Provided by Northeast Power Systems, Inc.


-BS2 = Limit contacts for signalling closing springs possibility of continuous control of the winding
charged/discharged. (see note D).
-MO1 = First shunt opening release (see note D). Fig. 9 = Circuit of the second shunt opening release with
-MO2 = Second shunt opening release (see note D). possibility of continuous control of the winding
-MO3 = Opening solenoid for release outside the circuit- (see note D).
breaker. Fig. 10 = Opening solenoid for release outside the circuit-

www.nepsi.com
-MO4 = Third shunt opening release (see note D). breaker.
-MC = Shunt closing release (see note D). Fig. 26 = Electrical signalling of closing springs charged
-MS = Motor for closing spring charging (see note C). and discharged.
-MU = Undervoltage release (see note B). Fig. 30 = Circuit-breaker auxiliary passing contact with
-QB = Circuit-breaker accessories. momentary closing during circuit-breaker
-RL1 = Locking magnet. If de-energized, it mechanically opening.
prevents circuit-breaker closing (it is possible to Fig. 31 = Available circuit-breaker auxiliary contacts.
limit its consumption by connecting a delayed Fig. 32 ÷ 35 = Available circuit-breaker auxiliary contacts. It
pushbutton in series to enable the operation). is possible to have one of these figures. The
-SC = Pushbutton or contact for circuit-breaker closing. standard configuration is figure 32.
-SO = Pushbutton or contact for circuit-breaker Fig.60 = Contact for the undervoltage release de-
opening. energized electrical signal.
-XB = Terminal box for the circuit-breaker circuits. Fig. 70 to 73 = Available auxiliary contacts of the circuit-breaker.
-XB2...16 = Accessory connectors. One of these figures can be obtained.

99
5. Electric circuit diagram

Selection of the figures Incompatibility


Description Figures Notes
The combination of circuits given in the figures below are not
-MS Spring charging motor 1 C
possible on the same circuit-breaker:
-MC Shunt closing release 2 D
-MO1 Shunt opening release 7 D
32-33-34-35
-MU Undervoltage release 5 B
-MO2 Additional shunt opening release 9 D
Notes
-BB1 -BB2 Set of 10 circuit-breaker auxiliary contacts 31
A) The circuit-breaker is only fitted with the accessories specified
in the order acknowledgement. To draw up the order, please
Set of 5 extra circuit-breaker auxiliary
32 consult this catalogue.
contacts 3C-20
Set of 5 extra circuit-breaker auxiliary B) The undervoltage release can be supplied for power supply
33
contacts 5C branched on the supply side of the circuit-breaker or from an
Set of 5 extra circuit-breaker auxiliary independent source.
34
contacts 2C-30 Circuit-breaker closing is only possible with the undervoltage

Provided by Northeast Power Systems, Inc.


-BB3
Set of 5 extra circuit-breaker auxiliary release energized (the lock on closing is made mechanically).
35
contacts 50
In the case where there is the same power supply for the shunt
Notes:
C = normally open contact with
closing and undervoltage releases and automatic circuit-
circuit-breaker open breaker closing is required on return of the auxiliary voltage,
0 = normally closed contact with a delay of 50ms must be introduced between the moment of
circuit-breaker open
consent to the undervoltage release and energization of the

www.nepsi.com
-RL1 Locking magnet on operating mechanism 3
shunt closing release.
-BB4 Transient contact 30
Incompatible with -MO4.
Contact for signalling closing spring
-BS2 26 C) Check the auxiliary circuit power to verify the possibility of
charged/discharged
Opening solenoid for release outside the
starting several motors for charging the closing springs at the
-MO3 10 F
circuit-breaker same time.
-MO4 Third shunt opening release 6 D To prevent excessive consumption the closing springs must be
charged manually before energizing the auxiliary circuit.
D) The circuit for controlling the shunt opening release winding
continuity must only be used for this purpose.
It is possible to use the STU Test Unit to check continuity of the
various release.
E) When fig. 06 is required, contact -BB3 (41-42) of fig. 32-33
is not available and figs. 34-35 cannot be supplied. When
fig. 09 is required, contact -BB1 (43-44) of fig. 31 is not
available.

100
Electric circuit diagram of fixed circuit-breakers 1VCD 400099
The electric circuit diagram given in this section regards the fixed circuit-breakers with breaking capacity up to 50 kA.

Provided by Northeast Power Systems, Inc.


www.nepsi.com

101
Provided by Northeast Power Systems, Inc.
www.nepsi.com
5. Electric circuit diagram

102
Provided by Northeast Power Systems, Inc.
www.nepsi.com

103
5. Electric circuit diagram

Caption Description of figures


= Reference number of diagram figure. Fig. 1 = Motor circuit for closing spring charging (see note
* = See the note indicated by the letter. C).
-BB1,..2-3 = Circuit-breaker auxiliary contacts. Fig. 2 = Shunt closing release (anti-pumping is carried out
-BB4 = Circuit-breaker auxiliary passing contact with mechanically) (see note D).
momentary closing during opening. Fig. 3 = Locking magnet. When de-energised, it
-BB6 = Contact for the undervoltage release de- mechanically prevents circuit-breaker closing. It
energized electrical signal. is possible to limit consumption by connecting a
-BB11 = Contact to interrupt the –BB4 signal during the delay pushbutton in series to enable the operation.
manual opening operation. Fig. 5 = Instantaneous undervoltage release (see note B).
-BM = STU Test unit for supervision of shunt opening Fig. 6 = Circuit of third opening release with continuous
release and shunt closing release winding control of the winding (see note D).
continuity (see note D). Fig. 7 = Circuit of the first shunt opening release with
-BS1 = Spring-charging motor limit contacts. possibility of continuous control of the winding (see

Provided by Northeast Power Systems, Inc.


-BS2 = Limit contacts for signalling closing springs note D).
charged/discharged. Fig. 9 = Circuit of the second shunt opening release with
-MO1 = First shunt opening release (see note D). possibility of continuous control of the winding (see
-MO2 = Second shunt opening release (see note D). note D).
-MO4 = Third shunt opening release (see note D). Fig. 26 = Electrical signalling of closing springs charged and
-MC = Shunt closing release (see note D). discharged.

www.nepsi.com
-MS = Motor for closing spring charging (see note C). Fig. 30 = Circuit-breaker auxiliary passing contact with
-MU = Undervoltage release (see note B). momentary closing during circuit-breaker opening.
-QB = Circuit-breaker accessories. Fig. 31 = Available circuit-breaker auxiliary contacts.
-RL1 = Locking magnet. If de-energized, it mechanically Fig. 32 ÷ 35 = Available circuit-breaker auxiliary contacts. It
prevents circuit-breaker closing (it is possible to is possible to have one of these figures. The
limit its consumption by connecting a delayed standard configuration is figure 32.
pushbutton in series to enable the operation). Fig. 60 = Contact for the undervoltage release de-
-SC = Pushbutton or contact for circuit-breaker closing. energized electrical signal.
-SO = Pushbutton or contact for circuit-breaker Fig. 70 to 73 = Available auxiliary contacts of the circuit-breaker.
opening. One of these figures can be obtained.
-XB = Terminal box for the circuit-breaker circuits.
-XB2...16 = Accessory connectors.

104
Selection of the figures Incompatibility
The combination of circuits given in the figures below are not
Description Figures Notes possible on the same circuit-breaker:
-MS Spring charging motor 1 C
-MC Shunt closing release 2 D 32-33-34-35
-MO1 Shunt opening release 7 D
-MU Undervoltage release 5 B Notes
-MO2 Additional shunt opening release 9 D A) The circuit-breaker is only fitted with the accessories
-BB1 -BB2 Set of 10 circuit-breaker auxiliary contacts 31 specified in the order acknowledgement. To draw up the
Set of 5 extra circuit-breaker auxiliary order, please consult this catalogue.
32
contacts 3C-20
B) The undervoltage release can be supplied for power supply
Set of 5 extra circuit-breaker auxiliary branched on the supply side of the circuit-breaker or from an
33
contacts 5C
independent source.
Set of 5 extra circuit-breaker auxiliary Circuit-breaker closing is only possible with the undervoltage

Provided by Northeast Power Systems, Inc.


34
contacts 2C-30
-BB3 release energized (the lock on closing is made mechanically).
Set of 5 extra circuit-breaker auxiliary In the case where there is the same power supply for the shunt
35
contacts 50
closing and undervoltage releases and automatic circuit-
Notes: breaker closing is required on return of the auxiliary voltage,
C = normally open contact with
circuit-breaker open a delay of 50ms must be introduced between the moment of
0 = normally closed contact with consent to the undervoltage release and energization of the

www.nepsi.com
circuit-breaker open
shunt closing release.
-RL1 Locking magnet on operating mechanism 3
Incompatible with -MO4.
-BB4 Transient contact 30
C) Check the auxiliary circuit power to verify the possibility of
Contact for signalling closing spring starting several motors for charging the closing springs at the
-BS2 26
charged/discharged
same time.
Opening solenoid for release outside the To prevent excessive consumption the closing springs must be
-MO3 10 F
circuit-breaker
charged manually before energizing the auxiliary circuit.
-MO4 Third shunt opening release 6 d
D) The circuit for controlling the shunt opening release winding
continuity must only be used for this purpose.
It is possible to use the STU Test Unit to check continuity of the
various release.
E) When fig. 06 is required, contact -BB3 (41-42) of fig. 32-33
is not available and figs. 34-35 cannot be supplied.
When fig. 09 is required, contact -BB1 (43-44) of fig. 31 is
not available.

105
5. Electric circuit diagram

Electric circuit diagram of withdrawable circuit-breakers 1VCD 400047


The electric circuit diagram given in this section regards the withdrawable circuit-breakers with breaking capacity
up to 40 kA. For withdrawable circuit-breakers with motorized truck, see diagram 1VCD400048.

For circuit-breaker of ZS8.4 switchgears the following diagrams are available:


1VCD400080 Standard version
1VCD400085 Version with motorized truck.

Provided by Northeast Power Systems, Inc.


www.nepsi.com

106
Provided by Northeast Power Systems, Inc.
www.nepsi.com

107
Provided by Northeast Power Systems, Inc.
www.nepsi.com
5. Electric circuit diagram

108
Provided by Northeast Power Systems, Inc.
www.nepsi.com

109
5. Electric circuit diagram

Caption -MO2 = Second shunt opening release (see note D).


= Reference number of diagram figure. -MO3 = Opening solenoid for release outside the
* = See the note indicated by the letter. circuit-breaker.
-BB1,..2-3 = Circuit-breaker auxiliary contacts. -MO4 = Third shunt opening release (see note D).
-BB4 = Circuit-breaker auxiliary passing contact with -MC = Shunt closing release (see note D).
momentary closing during opening. -MS = Motor for closing spring charging (see note C).
-BB6 = Contact for the undervoltage release de- -MU = Undervoltage release (see note B).
energized electrical signal. -QB = Circuit-breaker accessories.
-BB11 = Contact to interrupt the –BB4 signal during the -RL1 = Locking magnet. If de-energized, it prevents
manual opening operation, mechanical closing of the circuit-breaker (it is
-BD = Enclosure door position contact. possible to limit its consumption by connecting
-BM = STU Test Unit for checking winding continuity of a delayed pushbutton in series to enable the
the shunt opening and closing release (see note operation).
D). -RL2 = Locking magnet (on the truck). If de-energized,

Provided by Northeast Power Systems, Inc.


-BS1 = Spring-charging motor limit contacts. it prevents mechanical connection and isolation
-BS2 = Limit contact for signalling closing springs of the circuit-breaker (it is possible to limit
charged/discharged. its consumption by connecting a delayed
-BT1 = Contacts for electrical signalling of circuit- pushbutton in series to enable the operation).
breaker in connected position (see note E). -SC = Pushbutton or contact for circuit-breaker
-BT2 = Contacts for electrical signalling of circuit- closing.

www.nepsi.com
breaker in isolated position (see note E). -SO = Pushbutton or contact for circuit-breaker
-BT3 = Circuit-breaker position contact, open during opening.
the circuit-breaker isolation run. -XB = Connector for the circuit-breaker circuits.
-MO1 = First shunt opening release (see note D). -XB2...16 = Accessory connectors.

Selection of the figures

Description Figures Notes


-MS Closing spring charging motor 1 C
-MC Shunt closing release 2 D
-MO1 Shunt opening release 7 D
-MU Undervoltage release 5 B
-MO2 Additional shunt opening release 9 D-F
-RL2 Locking magnet on the truck 8
-BB4 Auxiliary passing contact 30 F
-BS2 Contact for signalling closing spring charged/discharged 26
-MO3 Opening solenoid for release outside the circuit-breaker 10 F
-MO4 Third shunt opening release 6 D-F

110
Selection of the figures

Set of 10 Set of 5 other Circuit-breaker Position Locking Figures Notes


circuit-breaker circuit-breaker connected contact for magnet on
auxiliary auxiliary isolated withdrawable the operating
contacts contacts contact circuit-breakers mechanism
-BB1 -BB2 -BB3 -BT1 -BT2 -BT3 -RL1
X 31 F
X X 32 F
X X 31 / 51 E-F
X X X 32 / 51 E-F
X X X 3 / 31 / 51 E-F-G
X X X X 3 / 32 / 51 E-F-G
X X X 4 / 33 E-F-G
X X X X 4 / 34 E-F-G

Provided by Northeast Power Systems, Inc.


X X X X 4 / 33 / 52 E-F-G
X X X X X 4 / 34 / 52 E-F-G

www.nepsi.com
Incompatibility
The circuits given in the figures below cannot be supplied at C) Check the power available on the auxiliary circuit to verify
the same time in the same circuit-breaker: the possibility of starting several motors for charging the
closing springs at the same time. To prevent excessive
3-4 31-32-33-34 4-31-32 3-33-34 consumption the closing springs must be charged manually
31-32-52 33-34-51 51-52 5-6 before energizing the auxiliary circuit.
D) The circuit for controlling the shunt opening release winding
continuity must only be used for this purpose. It is possible
Notes to use the STU Shunt Test Unit to check continuity of the
A) The circuit-breaker is only fitted with the accessories winding.
specified in the order acknowledgement. To draw up the E) The contacts for electrical signalling of circuit-breaker
order, please consult the present catalogue. in the connected and isolated position (-BT1 and -BT2)
B) The undervoltage release can be supplied for power supply shown in fig. 51 or 52 are located in the circuit-breaker
branched on the supply side of the circuit-breaker or from truck
an independent source. Circuit-breaker closing is only F) When fig. 10 is requested, contact -BB3 31-32 indicated
possible with the undervoltage release energized (the lock of fig. 32-34 is not available. When fig. 30 is requested,
on closing is made mechanically). In the case where there contact -BB3 (53-54) indicated of fig. 32-34 is not
is the same power supply for the closing and undervoltage available. When fig. 9 is requested, contact -BB1 (43-44
releases and automatic circuit-breaker closing is required indicated) of fig. 31-32-33-34 is not available.
on return of the auxiliary voltage, a delay of 50ms must When fig. 06 is required, contact -BB3 (terminals 41-42) of
be introduced between the moment of consent to the figs. 32 and 34 is not available.
undervoltage release and energization of the shunt closing G) Fig. 3 is supplied when fig. 31 or 32 is requested. Fig. 4 is
release. supplied when fig. 33 or 34 is requested (in this case it is
Incompatible with -MO4. compulsory to supply the -BT3).

111
5. Electric circuit diagram

Electric circuit diagram of withdrawable circuit-breakers 1VCD 400100


The electric circuit diagram given in this section regards the withdrawable circuit-breakers with breaking capacity
up to 50 kA. For withdrawable circuit-breakers with motorized truck, see diagram 1VCD400102.

Provided by Northeast Power Systems, Inc.


www.nepsi.com

112
Provided by Northeast Power Systems, Inc.
www.nepsi.com

113
Provided by Northeast Power Systems, Inc.
www.nepsi.com
5. Electric circuit diagram

114
Provided by Northeast Power Systems, Inc.
www.nepsi.com

115
5. Electric circuit diagram

Caption -MO1 = First shunt opening release (see note D).


= Reference number of diagram figure. -MO2 = Second shunt opening release (see note D).
* = See the note indicated by the letter. -MO4 = Third shunt opening release (see note D).
-BB1,..2-3 = Circuit-breaker auxiliary contacts. -MC = Shunt closing release (see note D).
-BB4 = Circuit-breaker auxiliary passing contact with -MS = Motor for closing spring charging (see note C).
momentary closing during opening. -MU = Undervoltage release (see note B).
-BB6 = Contact for the undervoltage release de- -QB = Circuit-breaker accessories.
energized electrical signal -RL1 = Locking magnet. If de-energized, it prevents
-BB11 = Contact to interrupt the –BB4 signal during the mechanical closing of the circuit-breaker (it is
manual opening operation, possible to limit its consumption by connecting
-BD = Enclosure door position contact. a delayed pushbutton in series to enable the
-BM = STU Test Unit for checking winding continuity of operation).
the -RL2 = Locking magnet (on the truck). If de-energized,
shunt opening and closing release (see note D). it prevents mechanical connection and isolation

Provided by Northeast Power Systems, Inc.


-BS1 = Spring-charging motor limit contacts. of the circuit-breaker (it is possible to limit
-BS2 = Limit contact for signalling closing springs its consumption by connecting a delayed
charged/discharged. pushbutton in series to enable the operation).
-BT1 = Contacts for electrical signalling of circuit- -SC = Pushbutton or contact for circuit-breaker closing.
breaker in connected position (see note E). -SO = Pushbutton or contact for circuit-breaker
-BT2 = Contacts for electrical signalling of circuit- opening.

www.nepsi.com
breaker in isolated position (see note E). -XB = Connector for the circuit-breaker circuits.
-BT3 = Circuit-breaker position contact, open during the -XB2...16 = Accessory connectors.
circuit-breaker isolation run.

Selection of the figures

Description Figures Notes


-MS Closing spring charging motor 1 C
-MC Shunt closing release 2 D
-MO1 Shunt opening release 7 D
-MU Undervoltage release 5 B
-MO2 Additional shunt opening release 9 D-F
-RL2 Locking magnet on the truck 8
-BB4 Auxiliary passing contact 30 F
-BS2 Contact for signalling closing spring charged/discharged 26
-MO4 Third shunt opening release 6 D-F

116
Selection of the figures

Set of 10 Set of 5 other Circuit-breaker Position Locking Figures Notes


circuit-breaker circuit-breaker connected contact for magnet on
auxiliary auxiliary isolated withdrawable the operating
contacts contacts contact circuit-breakers mechanism
-BB1 -BB2 -BB3 -BT1 -BT2 -BT3 -RL1
X 31 F
X X 32 F
X X 31 / 51 E-F
X X X 32 / 51 E-F
X X X 3 / 31 / 51 E-F-G
X X X X 3 / 32 / 51 E-F-G
X X X 4 / 33 E-F-G
X X X X 4 / 34 E-F-G

Provided by Northeast Power Systems, Inc.


X X X X 4 / 33 / 52 E-F-G
X X X X X 4 / 34 / 52 E-F-G

www.nepsi.com
Incompatibility C) Check the power available on the auxiliary circuit to verify
The circuits given in the figures below cannot be supplied at the possibility of starting several motors for charging the
the same time in the same circuit-breaker: closing springs at the same time. To prevent excessive
consumption the closing springs must be charged manually
3-4 31-32-33-34 4-31-32 3-33-34 before energizing the auxiliary circuit.
31-32-52 31-34-51 51-52 5-6 D) The circuit for controlling the shunt opening release winding
continuity must only be used for this purpose.
It is possible to use the Shunt Test Unit to check continuity
Note of the winding.
A) The circuit-breaker is only fitted with the accessories E) The contacts for electrical signalling of circuit-breaker
specified in the order acknowledgement. To draw up the in the connected and isolated position (-BT1 and -BT2)
order, please consult the apparatus catalogue. shown in fig. 51 or 52 are located in the circuit-breaker
B) The undervoltage release can be supplied for power supply truck
branched on the supply side of the circuit-breaker or from F) When fig. 9 is required, contact -BB1 (terminals 41-42) of
an independent source. figs. 31-32-33-34 is not available. When fig. 30 is required,
Circuit-breaker closing is only possible with the contact -BB3 (terminals 53-54) of figs. 32 and 34 is not
undervoltage release energized (the lock on closing is available. When fig. 06 is required, contact -BB3 (terminals
made mechanically). 41-42) of figs. 32-34 is not available.
In the case where there is the same power supply for G) Fig. 3 is supplied when fig. 31 or 32 are required. Fig. 4 is
the closing and undervoltage releases and automatic supplied when fig. 33 or 34 are required (in this case, it is
circuit-breaker closing is required on return of the auxiliary obligatory for -BT3 to be supplied).
voltage, a delay of 50ms must be introduced between
the moment of consent to the undervoltage release and
energization of the shunt closing release.
Incompatible with -MO4

117
Provided by Northeast Power Systems, Inc.
www.nepsi.com

118
Provided by Northeast Power Systems, Inc.
www.nepsi.com

119
Contact us

ABB S.p.A. The data and illustrations are not binding. We reserve

1VCP000001 - Rev. T, en - Technical catalogue - 2012.06 (VD4-50 kA) (gs)


the right to make changes without notice in the course
Power Products Division of technical development of the product.
Unità Operativa Sace-MV
© Copyright 2012 ABB. All rights reserved.
Via Friuli, 4
I-24044 Dalmine
Tel.: +39 035 6952 111
Fax: +39 035 6952 874
e-mail: info.mv@it.abb.com

ABB AG
Calor Emag Medium Voltage Products
Oberhausener Strasse 33 Petzower Strasse 8

Provided by Northeast Power Systems, Inc.


D-40472 Ratingen D-14542 Glindow
Phone: +49(0)2102/12-1230, Fax: +49(0)2102/12-1916
E-mail: powertech@de.abb.com

www.abb.com

www.nepsi.com

Potrebbero piacerti anche