SELF-ADHESIVE MEMBRANES

VAPORSTOP CA 500
ULTRAFLEX SA NBS
ULTRAFLEX SA
ULTRAFLEX SA NB
ULTRAFLEX SA 1.5 mm STRONG P
ULTRAFLEX SA 1.5 mm STRONG G

KNOWLEDGE. EXPERIENCE. CRAFTSMANSHIP. WWW.TECHNONICOL.IN


SELF-ADHESIVE MEMBRANES

Long operational lifetime, reliability and convenience of installation – ADVANTAGES:


that’s the ideal waterproofing. Any defect, especially when it comes to
foundations, will certainly lead to destruction of the entire system and Application on Application on
huge financial losses to the customer. surfaces, where surfaces of any
torch-on application complexity
Application of self-adhesive materials make possible to install reliable is prohibited
waterproofing where the standard torch-on application is forbidden,
and high flexibility and elasticity allow the materials to be used on Simple Does not require
surfaces of any complexity and in limited space. installation extra equipment

APPLICATION AREA:

 Waterproofing of underground (below-grade) parts of premises and Quick installation Cold application
engineering structures prevents smoke,
 Indoor waterproofing of premises and buildings odors and noise
 Waterproofing of confined area, where standard technologies
cannot be applied (bathroom floor). Can be used in parquetry and
floor installation Self-adhesive waterproofing is a type of materials, that combines all
 As an underlay on pitched roofs and as a vapor barrier on the advantages of torch-on applied materials and non-torch-on
the corrugated steel sheets and precast concrete slabs installation, which helps to avoid issues associated with the use of
 Corrosion protection of steel pipes and junctions flame.

2
VAPORSTOP CA 500

VAPORSTOP CA 500 ADVANTAGES:


Vapor barrier with aluminum foil intended to use as a reliable vapor-
proofing layer in any roofing constructions.  High workforce productivity –
few installation steps
Self-adhesive bottom surface and high tensile strength ensure  Easy to install an ideal vapor
the ability of the material to withstand the weight of the person barrier
standing between the corrugations of the profiled metal deck without  Vapor permeability Sd = 1000
breaking or stretching.  Mechanically stable –
withstand the weight of the
INTENDED USE: person

Material is used as a vapor barriers in construction of public and


industrial buildings with normal temperature and humidity conditions
(malls, warehouse complexes, sport centers etc.). PROPERTIES VAPORSTOP CA 500

Mass per unit area, kg/m2 0.5±0.10


Peel resistance of joints, N/50mm ≥50
Flexibility / Flow resistance, °С ≤-25 / ≥90
Tensile strength L / T, N/50 mm 600±120 / 600±120
Reinforcement type glass net
Protective covering type: top / bottom aluminum foil / anti-adhesion film
Length х width, m 50 × 1.08

3
VAPORSTOP CA 500

SOLUTION EXAMPLES:

4
VAPORSTOP CA 500

METHOD OF APPLICATION:

Convenience, simplicity and safety of installation of the membrane are due to the special adhesive polymer-bitumen layer, which allows
installation of the material without additional equipment.

1 2 3 4

Cut the siliconized anti-adhesion Remove the protective film from Press the place of the first Continue attaching membrane to
film at the distance of 30-40 cm the edge of the roll and attach adhesion by roller for the whole the base. One worker pulls
from the beginning of the roll by the membrane to the surface. width of the membrane. the film off, while the other
means of roofing knife. smooths the membrane by brush.

5
ULTRAFLEX SA NBS

ULTRAFLEX SA NBS ADVANTAGES:

Used for indoor waterproofing with the direct installation of ceramic  Material is installed in one
tiles onto the material without the need of protective sand cement layer unlike cement based
screed (spunbond has to be treated with the contact primer before waterproofing, which requires
application of tile adhesive). Can be used on bases, where the several layers
standard torch-on application is forbidden (wood, XPS, etc.).  No need to wait for the screed
to dry
MATERIAL STRUCTURE:  Tiles are installed directly on
the material
1. Polypropylene (Spunbond)
Protects waterproofing layer from mechanical damage. Provides
strong sticking of the tile adhesive when treated with the contact
primer PROPERTIES ULTRAFLEX SA NBS
2. Self-adhesive polymer-bitumen compound Mass per unit area, kg/m2 1.5±0.25
High elasticity index of this layer allows installation of the
Thickness, mm 1.5±0.10
membrane on surfaces of any complicated shape
3. Easy-removable protective film Flexibility / Flow resistance, °С ≤-15 / ≥85
Used for underside surface protection from sticking in the roll Tensile strength, N/50 mm NPD

Reinforcement type no base

Protective covering type: top / bottom spunbond / anti-adhesion film

Length x width, m 20 × 1

6
ULTRAFLEX SA NBS

SOLUTION EXAMPLES:

7
ULTRAFLEX SA

ULTRAFLEX SA ADVANTAGES:

Self-adhesive polyester reinforced SBS-modified bitumen membrane  Self-adhesive


ULTRAFLEX SA is designed to complete secure application. It is used  Simple and quick installation
as an underlay on pitched roofs and as a vapor barrier. Could also be  High speed of application
used for waterproofing of foundations and engineering structures.  Dimensional stability
Non-skid upper layer from fine-grained sand provide safe movement  Safety of work
on the roof during installation.

MATERIAL STRUCTURE:

1. PE film or sand
Protects waterproofing layer from mechanical damage and
prevents adhesion of the material in the roll PROPERTIES ULTRAFLEX SA
2. Polymer-bitumen compound Mass per unit area, kg/m2 1.8±0.20
Provides reliable waterproofing
Thickness, mm 1.5±0.20
3. Polyester
Provides excellent elongation and grants optimal strength to Flexibility / Flow resistance, °С ≤-20 / ≥90
the material
Tensile strength L / T, N/50 mm 400±100 / 300±100
4. Self-adhesive polymer-bitumen compound
Self-adhesive layer allows to install the material on combustible Reinforcement type polyester
surfaces Protective covering type: top / bottom polymer film or sand / anti-adhesion film
5. Easy-removable protective film
Length x width, m 20 × 1
Used for underside surface protection from sticking in the roll
8
ULTRAFLEX SA

SOLUTION EXAMPLES:

9
ULTRAFLEX SA NB

ULTRAFLEX SA NB ADVANTAGES:

Self-adhesive carrier less SBS-modified bitumen membrane  Self-adhesive


ULTRAFLEX SA NB is designed for waterproofing of foundations and  Simple and quick installation
engineering structures, indoor waterproofing. Thanks to the special  High speed of application
adhesive bitumen compound, the material can be used on surfaces,  High elasticity
where the standard torch-on application is forbidden (expanded /
extruded polystyrene or wooden base). The absence of a carrier is
a key feature of this material that makes it very elastic and flexible.

MATERIAL STRUCTURE:

1. PE film for mechanical protection


Protects waterproofing layer from mechanical damage and PROPERTIES ULTRAFLEX SA NB
impacts of chemically aggressive media Mass per unit area, kg/m2 1.5±0.25
2. Self-adhesive polymer-bitumen compound
Thickness, mm 1.5±0.10
High elasticity of this layer preserves waterproofing undamaged
when cracks and splits occur in the foundation Flexibility / Flow resistance, °С ≤-15 / ≥85
3. Easy-removable protective film
Tensile strength L / T, N/50 mm NPD
Used for underside surface protection from sticking in the roll
Reinforcement type no base
Protective covering type: top / bottom thick polymer film / anti-adhesion film
Length x width, m 20 × 1

10
ULTRAFLEX SA NB

SOLUTION EXAMPLES:

11
ULTRAFLEX SA 1.5 mm STRONG

ULTRAFLEX SA 1.5 mm STRONG ADVANTAGES:

Self-adhesive polyester / glass fiber reinforced SBS-modified bitumen  Self-adhesive


membrane ULTRAFLEX SA 1.5 mm STRONG is designed for  Simple and quick installation
waterproofing of foundations and engineering structures. On the top  High speed of application
side, the material is covered with a special thick PE film that grants  Dimensional stability
additional tensile properties and elongation. The other side of the  Additional protection from
material is covered with a removable protective film. mechanical impacts

MATERIAL STRUCTURE:

1. Thick PE film for additional mechanical protection


Protects waterproofing layer from mechanical damage and
impacts of chemically aggressive media PROPERTIES P G
2. Polymer-bitumen compound Mass per unit area, kg/m2 1.7±0.20
Provides reliable waterproofing
Thickness, mm 1.5±0.20
3. Polyester (P) / Glass fiber (G)
Reinforced carrier makes the material stable to tension and Flexibility / Flow resistance, °С ≤-20 / ≥85
deformation
Tensile strength L / T, N/50 mm 400 / 300 (±100) 350 / 200 (±100)
4. Self-adhesive polymer-bitumen compound
High elasticity of this layer preserves waterproofing undamaged Reinforcement type polyester glass fiber
when cracks and splits occur in the foundation Protective covering type: top / bottom thick film / protective film
5. Easy-removable protective film
Length x width, m 20 × 1
Used for underside surface protection from sticking in the roll
12
ULTRAFLEX SA 1.5 mm STRONG

SOLUTION EXAMPLES:

13
METHOD OF APPLICATION

FLAT ROOF OR INDOOR WATERPROOFING

1 2 3 4

Clean and treat the surface with Fit and straighten the membrane Re-roll the membrane to the Remove the protective film and
bitumen primer. to the area of application. center, pre-cut the protective film. smooth the membrane.

14
METHOD OF APPLICATION

FLAT ROOF OR INDOOR WATERPROOFING

5 6 ! Self-adhesive materials to be installed at the temperatures above


+10 °С.

! Surface must be smooth, dry, clean and with no oil stains.

Longitudinal overlaps: 80- On a vertical surface the material


100 mm. End overlaps: 150 mm. to be placed on a height,
Overlaps to be glued with sufficient according to the
bitumen mastic of 1 mm thickness of the floor and
thickness. decoration.

15
METHOD OF APPLICATION

FOUNDATION WATERPROOFING

1 2 3 4

Surface must be smooth, dry, Measure the depth of the Apply the material from top The material to be installed to
clean and with no oil stains. For foundation and cut the material to downward by gradual removing the height of 30-50 cm above
better adhesion, treat the surface the required length. the protective film, unrolling the ground level. Longitudinal
with primer. the membrane and smoothing it overlaps should be 100 mm,
to the surface. sheet end overlaps - 150 mm.

16
METHOD OF APPLICATION

FOUNDATION WATERPROOFING

5 ! !

The top end of the waterproofing Protect the membrane from As a protection from mechanical
membrane to be fixed at mechanical damage by means of impacts, one can also use
basement level by profiled metal thermal insulation or protective PLANTER HDPE membrane.
edge strip and sealed. slabs.

17
THANK YOU FOR ATTENTION!

TECHNONICOL India Private Limited


+91 22 2872 8691
info@technonicol.in

WWW.TECHNONICOL.IN