FREQUENTLY ASKED QUESTIONS
Q. What current options are automatically distributed among load 48VDC. The solution is highly efficient;
available for backup power and battery, while supplying power up to 91% via switching technology.
solutions? to the load always is the first priority. The ultra-capacitor solution stores
A. Systems that require backup The maximum available current of the energy within a compact design that
power solutions usually have small load output is two times the value of does not use a battery but supper
battery backups or generators. Small the device’s rated current. If the device capacitors to store energy. The load
backup systems traditionally rely on is disconnected from the main power is energized from the buffer module
batteries for energy storage while source, the battery will supply the load until it is depleted. The capacitors are
larger systems may use generators until the battery voltage reaches 1.5 V either a 12 or 24V system design.
or more uncommon systems such as per cell. This prevents the battery from It operates between temperatures
flywheels, superconducting magnetic deep discharge. The battery charging is of -40°F to 140°F and can provide
energy storage, or fuel cells for larger controlled via a microprocessor. Using up to 10,000 watts of energy plus
installations. While there can be a need algorithms, the battery’s condition will extension modules. The system can be
for a battery based solution, batteries be detected and based on that, an customized up to 600A. Backup times
have a limited life span. Their life is appropriate charging mode is chosen. depend on the state of the charge of
based on the number of discharges The real-time diagnostics system will the ultra-capacitors and the load in
and charges they undergo. Battery continuously monitor the charging which they are supplying. Compared to
installations are difficult due to the long progress and indicate possibly occurring standard buffer modules, ultra-capacitor
list of regulations and standards they faults such as elements in short circuit, units are capable of prolonged
must abide. Their installations must accidental reverse polarity connection backup times (up to 55 minutes)
comply with local and national health or disconnection of the battery by the and fast discharges. Capacitors excel
and safety standards. Environmental battery fault LED and a flashing code at controlled shutdown functions
regulations, which mainly affect larger of the diagnosis LED. The all-in-one and allowing for the protection of
installations, can include requirements solution can provide a variety of computer systems. Backup times are
for ventilation, handling, and disposal charging voltages: 12VDC, 24VDC, and dependent on the load and amount
of batteries. Flywheels, for example,
require an extreme amount of
maintenance. Also, systems that use
generator sets and fuel cells have poor
turn-on response and are not very
reliable.
Q. What alternatives provide a
more secure and reliable power
source?
A. Two alternatives that can be used
instead of generators are an all-in-one
power solution system and an ultra-
capacitor system.
An all-in-one power solution
combines a power supply unit, battery
charger, battery care module, or backup
module. The all-in-one battery solution
is based on the battery operating as
a storage device (batteries are not
included). The available power is