STANDARD SPECIFICATION

FOR

AUTOCAD DESIGN,

PREPARATION OF DRAWINGS,

AND DOCUMENT DELIVERY

PREPARED BY

CERTAINTEED CENTRAL ENGINEERING

INSULATION GROUP

CERTAINTEED CORPORATION

THIS SPECIFICATION IS THE PROPERTY OF CERTAINTEED


CORPORATION AND ALL OF THE INFORMATION CONTAINED HEREIN IS
TO BE KEPT CONFIDENTIAL BY THE RECIPIENT AND NOT TO BE
DISCLOSED TO ANY OTHER PERSON, FIRM OR CORPORATION
WITHOUT THE EXPRESSED WRITTEN CONSENT OF CERTAINTEED
CORPORATION. THIS SPECIFICATION SHALL NOT BE USED, DIRECTLY
OR INDIRECTLY, EXCEPT IN CONNECTION WITH THE WORK
PERFORMED FOR CERTAINTEED CORPORATION. ALL RIGHTS OF
DESIGN OR INVENTION ARE RESERVED.

DATE: January 18, 2008


REVISION: D
CertainTeed
1.0 GENERAL

1.1 This specification is intended for both in-house engineering personnel and engineering firms
generating CAD drawings for CertainTeed.

1.2 The preferred CAD system for CertainTeed is AutoCAD (latest version) and the support files provided
by CertainTeed. All CAD drawings shall be generated using the preferred system, unless acceptable
alternate arrangements have been made prior to the start of work.

1.3 Start all new drawings using the drawing template provided by CertainTeed [CT_Standard – 2008
Template.DWT] Follow this naming convention:

Drawing Number: 01-03-42-0266-C2


CAD File Name: 01-03-42-0266-C2.dwg
Reference the Drawing Number Table to understand numeric designations

Revisions, designated by letters on the title block - A, B, C, D, etc., are to indicate a change in
issuance, which would be considered a major change. Changes to the actual content of the drawing
are to be designated by numbers attached to the major change. For example:

A = Original Issue
A0-Ax = Content Change Revisions
B = Issuance Change (Issued for Bid for example)
B0-Bx = Content Change Revisions
C = Issuance Change (Issued For Construction for example)

1.4 Utilize the Text styles provided within the CertainTeed’s drawing template file.

1.5 Utilize the Dimension styles provide within the CertainTeed’s drawing template file.

1.6 Utilize the Layouts provided within the CertainTeed’s drawing template file. Delete unused layouts. All
drawing elements shall be drawn at full scale.

1.7 Layer names are to be descriptive rather than encrypted. Related layers will use prefixed layer names.

1.8 Drawing elements shall have their color “ByLayer”. All other element properties such as line weight
and/or line type can be driven “ByLayer” or explicitly set.

1.9 Blocks shall be created with their nested elements on layer “0” only, using color “ByBlock” and linetype
“ByBlock”.

1.10 Although External reference drawings can be used internally by vendors, they shall not be used for a
delivered drawing. An “external reference drawing” links (or attaches) one drawing to another. XREF’s
must be bound to the host file(s) using the “bind” command.

2.0 DOCUMENT DELIVERABLE TO CERTAINTEED

2.1 All saved drawings shall have zoom states saved to the extent of the Layout tab.

2.2 Except for the “CT_” series items, purge all drawings, including nested entities.

2.3 Final documentation shall be provided on CD-R.

-1-
CertainTeed
3.0 AUTOCAD AND SUPPORT FILES

3.1 All drawings shall be generated using AutoCAD and CertainTeed support files, unless acceptable
arrangements are made prior to the start of the work.

3.2 Best Practice – All software features and technology are to be utilized appropriately and as intended.

4.0 Dimension styles

4.1 Refer to TABLE 1 for relationships between scale, scale factor and text size.

4.2 Scaling of dimensions is automatically done when dimensioning through or onto a layout viewport. Be
certain that the viewport scale is appropriately set and “Display locked” before dimensioning.
AutoCAD “Spacetrans” command is also useful for scaling text easily and appropriately.

5.0 Layouts

5.1 Drawing elements are to be drawn at full scale in the Model Tab – also known as Model Space. As
configured within the supplied template, the title block is to be onto a Layout Tab – also known as
Paper Space. When scaling is not a drawing requirement – for instance a schematic – drawing
elements shall be drawn on the same layout as the title block..

6.0 Layer Names

6.1 Layer names are to be descriptive rather than encrypted. Related layers will use prefixed layer names.
The following are examples:

Descriptive Names: Annotation, Text, Mechanical, Plumbing, Electrical…


Prefixed Layer Names: Plumbing_Water_Cold, Plumbing_Water_Hot…

7.0 Element Properties

7.1 All elements requiring line weight will have the line weight assigned either “ByLayer” or explicitly set,
eliminating the need for the plot configuration files. Linetype shall also be drawn “ByLayer” and/or
explicitly set.however, drawing elements shall be drawn with color assigned “ByLayer” only.

8.0 Blocks

8.1 Minor elements within a block requiring different line weight and/or linetype than the major portions of
the block will be assigned the specific properties per above paragraph.

-2-
Plant Designations: Plant Functions:
01. Mountaintop, PA
02. Tyler, TX 01. Land 43. Cullet System
03. Shelbyville, IN 02. Site Work 44. Fiberizing System
04. Corbin, KY 03. Railroad 50. Mat Line Common Facilities
05. Kansas City, KS, Plant 5 04. Buildings 51. Forming System
06. Chowchilla, CA 05. Electrical Supply 52. Mat Line Structures
07. Kansas City, KS, Plant 7 06. Electrical Distribution 53. Curing Oven
08. Athens, GA 07. Water Supply 54. Finishing Equipment
09. Berlin, NJ 08. Water Distribution 55. Packaging Equipment
10. Atlanta, GA (Flexduct) 09. Cooling Water Supply 56. Rammix
11. Sherman, TX 10. Cooling Water Distribution 60. Pipe Common Facilities
50. Corporate 11. Compressed Air Supply 61. Pipe Forming System
12. Compressed Air Distribution 62. Pipe Machines
13. Steam Supply 63. Pipe Finishing Equipment
Discipline: 14. Steam Distribution 64. Pipe Packaging Equipment
00. Flow Diagrams, P&IDs 15. Fuel Supply 70. Insulsafe Shredding
01. Electrical/Instrumentation 16. Fuel Distribution 71. Insulsafe Distribution
03. Mechanical 17. Fire Protection System 72. Insulsafe Fiber Conditioning (Sepr & Conv)
04. Refractory 18. Fire Protection Distribution 73. Insulsafe Milling
-3-

05. Architectural 19. Sanitary Sewer System 74. Insulsafe Finishing Equipment (Nodulate)
06. Structural 20. Sanitary Sewer System Distribution 75. Insulsafe Packaging
07. Civil 21. Wash Water Treatment System 79. Polystructures MFG Equipment
08. Plumbing and Piping 22. Wash Water Filtering and Cooling 80. Blowing Wool and Off Line Equipment
09. HVAC 23. Strom Water Drainage System 81. Tooling Equipment for Fiberizing
24. Combustion Air Supply 85. Finished Product Handling System
25. Combustion Air Distribution 86. Solid Waste and Scrap Disposal System

CertainTeed
30. Batch Plant 87. Warehouse Service Equipment
31. Batch Distribution 88. HVAC Equipment
01-03-50-9999-C2 32. Resin
33. Binder Preparation
90. Q.C. Equipment
91. R&D Lab Equipment
34. Binder Distribution 92. Maintenance Equipment
4 Digit Drawing Number: 35. Asphalt Supply 93. Communication Equipment
Assigned by CertainTeed 36. Asphalt Distribution 94. Sales Office Tooling
39. Process Structures 95. Data Process Equipment
40. Glass Common Facilities 96. Office Equipment
Revision Level: 41. Furnace 97. Precious Metal
42. Forehearth 98. Precious Metal Fab Equipment
CertainTeed

TEXT SIZES IN INCHES


SCALE
SCALE
FACTOR 3/32 1/8 3/16 1/4

3/32”=1’-0” 128 12” 16” 24” 32”


1/8”=1’-0” 96 9” 12” 18” 24”
3/16”=1’-0” 64 6” 8” 12” 16”
1/4”=1’-0” 48 4.5” 6” 9” 12”
3/8”=1’-0” 32 3” 4” 6” 8”
1/2”=1’-0” 24 2.25” 3” 4.5” 6”
3/4”=1’-0” 16 1.5” 2” 3” 4”
1”=1’-0” 12 1.125” 1.5” 2.25” 3”
1 ½”=1’-0” 8 0.75” 1” 1.5” 2”
3”=1’-0” 4 0.375” 0.5” 0.75” 1”
6”=1’-0” 2 0.1875” 0.25” 0.375” 0.5”
FULL SCALE 1 0.09375” 0.125” 0.1875” 0.25”

TABLE 1
SCALE / SCALE FACTOR / & TEXT SIZE

-4-
CertainTeed

Title Block Details

Template Layout

-2-