Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operation.
Failure to do so can result in death or
electrical shock.
No-Load Performance, Controls in Normal Position
Refrigerator Center Freezer
Compartment Compartment
Kw/24 hr ±0.4 Percent Run Time Cycles/24 hr Average Food Average
±10% ±25% Temperature Food Temperature
±3°F ±3°F
Ambient °F 70° 90° 110° 70° 90° 110° 70° 90° 110° 70° 90° 110° 70° 90° 110°
Ambient °F 70° 90° 70° 90° 70° 90° 70° 90° 70° 90° 70° 90°
Mid Level -20 -17 -20 -17 85 105 125 130 6”(Vac.) 1 85 135
Electronic
Component Specifications
Component Specifications all parts
115VAC/60HZ unless noted
Compressor run capacitor Volt......................................................... 210 VAC 180 VAC or 210 VAC
Capacitance........................................... 15 µfd ± 10% 12 µfd ± 10%
Overload/Relay Ult. trip amps @ 158°F (70°C).............. 2.60 amps± 15% 3.06 amps± 15%
Close temperature............................... 140°F ±18° 142°F ±16°
Open temperature............................... 239°F ±9° 221°F ±9°
Short time trip (seconds)........................ 14 seconds ±4 5-15 seconds
Short time trip (amps @77°F (25°C)..... 12 amps ±2amps 14.5 amps ±2amps
Wiring Diagram
Note: Adjustments of Service Test 7 or Service Test 8 will alter the performance of the unit.