No-Load Performance, Controls in Normal Position
Refrigerator Center Freezer
Compartment Compartment
Kw/24 hr ±0.4 Percent Run Time Cycles/24 hr Average Food Average
±10% ±25% Temperature Food Temperature
±3°F ±3°F

Ambient °F 70° 90° 110° 70° 90° 110° 70° 90° 110° 70° 90° 110° 70° 90° 110°

Mid Level 1 1.6 2.3 30 50 65 39 35 24 38 36 35 0 0 0


Electronic

Temperature Relationship Test Chart


Evaporator Evaporator
Outlet Inlet Suction Line Average Total Suction Pressure Head Pressure
±3°F ±3°F ±7°F Wattage ±10% ±2 PSIG ± 5 PSIG

Ambient °F 70° 90° 70° 90° 70° 90° 70° 90° 70° 90° 70° 90°

Mid Level -20 -17 -20 -17 85 105 125 130 6”(Vac.) 1 85 135
Electronic

Component Specifications
Component Specifications all parts
115VAC/60HZ unless noted

Compressor run capacitor Volt......................................................... 210 VAC 180 VAC or 210 VAC
Capacitance........................................... 15 µfd ± 10% 12 µfd ± 10%

With GE PTC Relay With Embraco TSD Relay

Compressor BTUH..................................................... 695 BTUH 695 BTUH


Watt....................................................... 60 Hz / 124 watts 60 Hz / 121 watts
Current Lock rotor.................................. 13.3 amps± 15% 13.3 amps± 15%
Current Full load.................................... 2.0 amps± 15% 2.00 amps± 15%
Resistance Run windings...................... 3.6 ohms± 15% 3.6 ohms± 15%
Resistance Start windings...................... 5.3 ohms± 15% 5.3 ohms± 15%

Electric damper control Maximum closing time........................... 8 seconds


Temperature Rating............................... 20°F- 110°F
RPM....................................................... 5

Thermistor Temperature........................................... Resistance


77°F........................................................ 10,000 ohms± 1.8%
36°F........................................................ 29,500 ohms± 1.0%
0°F.......................................................... 86,300 ohms± 1.8%

Condenser motor Rotation (facing end opposite shaft)...... Clockwise


RPM....................................................... 1120 RPM
Watt........................................................ 3.4 watts±15%@115VAC
Current................................................... 0.085 amps± 15%@115VAC

Evaporator fan motor Rotation (facing end opposite shaft)...... Clockwise


RPM....................................................... 2800 RPM
Watt........................................................ 6.0±15% watts@115 VAC
Note: Fan blade must be fully seated
on shaft to achieve proper airflow.

Overload/Relay Ult. trip amps @ 158°F (70°C).............. 2.60 amps± 15% 3.06 amps± 15%
Close temperature............................... 140°F ±18° 142°F ±16°
Open temperature............................... 239°F ±9° 221°F ±9°
Short time trip (seconds)........................ 14 seconds ±4 5-15 seconds
Short time trip (amps @77°F (25°C)..... 12 amps ±2amps 14.5 amps ±2amps

Thermostat (Defrost) Volt........................................................ 120/240 VAC


Watt....................................................... 495 watts
Current................................................... 5.8/2.9 amps
Resistance across terminals: 56 K ohms
Above 42°F ±5°...................................... Open
Below 12°F ±7°...................................... Closed

Evaporator heater Volt......................................................... 115 VAC


Wattage.................................................. 435 ±5% watts @ 115VAC(22 cubic ft. models)
470 ±5% watts @ 115VAC(25 cubic ft. models)
Resistance............................................. 29 ±5% ohms

Control board Volt......................................................... 120VAC, 60 HZ


See Control board troubleshooting section

Dual Water Valve Watts...................................................... Blue side 35w,Yellow side 20w

Ice Box Fan Rotation (facing end opposite shaft)...... Clockwise


RPM....................................................... 3000 RPM
Watt........................................................ 5.5 .9±15% watts@12 VDC
Note: Fan blade must be fully seated
on shaft to achieve proper airflow.

Light switch Type....................................................... SPDT NO/NC


Volt......................................................... 125/250 VAC
Current................................................... 8/4 amps

Control board Troubleshooting

JZ 19-25 1 2 12827967 02/08


Control board Troubleshooting (continued) Schematic

Wiring Diagram

Note: Adjustments of Service Test 7 or Service Test 8 will alter the performance of the unit.

JZ 19-25 3 4 12827967 02/08