Sei sulla pagina 1di 28

Journal of Oral Implantology

Conservative implant removal for the analysis of the cause, removal torque and
surface treatments of failed nonmobile dental implants
--Manuscript Draft--

Manuscript Number: aaid-joi-D-14-00207

Full Title: Conservative implant removal for the analysis of the cause, removal torque and
surface treatments of failed nonmobile dental implants

Short Title: Conservative implant explantation

Article Type: Clinical Research

Keywords: Periimplantitis; explantation; implant removal; counter-torque; surface treatment

Corresponding Author: Eduardo Anitua, Ph.D, M.D., D.D.S


Eduardo Anitua Foundation
Vitoria, Álava SPAIN

Corresponding Author Secondary


Information:

Corresponding Author's Institution: Eduardo Anitua Foundation

Corresponding Author's Secondary


Institution:

First Author: Eduardo Anitua, Ph.D, M.D., D.D.S

First Author Secondary Information:

Order of Authors: Eduardo Anitua, Ph.D, M.D., D.D.S

Alia Murias-Freijo, DDS, MPhil

Mohammad Hamdan Alkhraisat, DDS, PhD

Order of Authors Secondary Information:

Abstract: This study was performed to study the effect of implant surface treatment on the cause
and removal torque of failed nonmobile implants. Implant explantation was achieved
by the application of counter-torque at the implant-bone interface. The explantation
socket was carefully examined and curetted to remove any granulation tissue.
Immediate implant placement was accomplished when primary stability could be
achieved. Eighty one patients were treated according to the described treatment
protocol for the explantation of 158 nonmobile implants in the maxilla and the
mandible. The patient's mean age was 62 ± 11 years. The main cause of implant
explantation was peri-implantitis (131 implants; 82.9%) followed by mal-positioning of
the implants (22 implants; 13.9%). The explantation of 139 implants at 146 ± 5 Ncm
was performed without the need for trephine bur. However, the use of trephine burs to
cut into the first 3-4 mm were necessary in 19 explantations and the removal torque
was 161 ± 13 Ncm. All titanium plasma sprayed implants were removed due to
periimplantitis at a significantly lower torque when compared to acid etched, particle
blasted and oxidized implants. The postoperative recovery of the patients was
uneventful and the conservation of the available hard and soft tissues was successfully
achieved. The protocol followed in this study could constitute a real alternative to other
traumatic technique for the removal of failed implants and advanced stages of peri-
implantitis. The type of implant surface treatment could influence the value of removal
torque and the occurrence of periimplantitis.

Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation
Article File

Conservative implant removal for the analysis of the cause, removal torque and surface
1 treatment of failed nonmobile dental implants
2
3
4
5
6
7 Anitua E1,2 MD, DDS, PhD, Murias-Freijo A1,2 DDS, MPhil, Alkhraist MH2 DDS, PhD.
8
9
10 1
Private practice in oral implantology, c/ Jose Maria Cagigal 19, 01007 Vitoria, Spain
11
2
12 Eduardo Anitua Foundation, c/ Jose Maria Cagigal 19, 01007 Vitoria, Spain.
13
14
15
16
17
18
19
20
21
22 Short title: Conservative implant explantation
23
24
25
26
27
28
29
30
31
32
33 Correspondence address: Dr. Eduardo Anitua, Eduardo Anitua Foundation; C/ Jose Maria
34
35 Cagigal 19, 01007 Vitoria, Spain; Phone: +34 945160653, e-mail:
36
37
38 eduardoanitua@eduardoanitua.com
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62 1
63
64
65
Abstract
1
2
3 This study was performed to study the effect of implant surface treatment on the cause and
4
5 removal torque of failed nonmobile implants. Implant explantation was achieved by the
6
7
application of counter-torque at the implant-bone interface. The explantation socket was
8
9
10 carefully examined and curetted to remove any granulation tissue. Immediate implant
11
12 placement was accomplished when primary stability could be achieved. Eighty one patients
13
14
15 were treated according to the described treatment protocol for the explantation of 158
16
17 nonmobile implants in the maxilla and the mandible. The patient's mean age was 62 ± 11 years.
18
19
20 The main cause of implant explantation was peri-implantitis (131 implants; 82.9%) followed by
21
22 mal-positioning of the implants (22 implants; 13.9%). The explantation of 139 implants at 146
23
24
25
± 5 Ncm was performed without the need for trephine bur. However, the use of trephine burs to
26
27 cut into the first 3-4 mm were necessary in 19 explantations and the removal torque was 161 ±
28
29 13 Ncm. All titanium plasma sprayed implants were removed due to periimplantitis at a
30
31
32 significantly lower torque when compared to acid etched, particle blasted and oxidized
33
34 implants. The postoperative recovery of the patients was uneventful and the conservation of the
35
36
37 available hard and soft tissues was successfully achieved. The protocol followed in this study
38
39 could constitute a real alternative to other traumatic technique for the removal of failed
40
41
42 implants and advanced stages of peri-implantitis. The type of implant surface treatment could
43
44 influence the value of removal torque and the occurrence of periimplantitis.
45
46
47
48
49
50
51 Key words: Periimplantitis; explantation; implant removal; counter-torque; surface treatment.
52
53
54
55
56
57
58
59
60
61
62 2
63
64
65
Introduction
1
2
3 The wide acceptance of dental implants as the choice to replace lost dentition have significantly
4
5 increased the number of patients being treated with implant-supported prosthesis. It is
6
7
estimated that more than half a million implants in United states, about 120 000 implants in
8
9 1, 2
10 France, 185 000 in Spain, 410 000 in Italy and 420 000 in Germany are placed every year .
11
12 This is partly motivated by the reliability and high success rate of implant-based oral
13
14
15 rehabilitation, making this option predictable and safe 3. The implant survival rate of implant-
16
17 supported fixed partial denture is reported to be 92-97% 4.
18
19
20
21
However, an implant failure rate of at least 3% is occurring and there will be a need to
22
23 efficiently resolve failure cases. Implant failure could arise as a result of infection
24
25 (periimplantitis), biomechanical stresses as well as improper positioning that may require the
26
27
28 removal of the implant 5.
29
30
31 Peri-implantitis is an inflammatory process around an implant, which includes both soft tissue
32
33
34 inflammation and progressive loss of supporting bone beyond biological bone remodeling 6.
35
36 Advanced stages of periimplantitis would result in severe bone loss around the dental implants
37
38
39
and indicate the need for implant removal.
40
41
42 Inadequate communication between the surgeon and restorative dentist would result in
43
44 improper implant positioning and/or angulations 7. Solutions for improper implant positions
45
46
47 include second surgeries or prosthetic compensation, solutions that will increase time and cost
48
8, 9
49 to achieve functioning prosthesis . Implant-osseous osteotomy and distraction osteogenesis
50
51
52
have been reported for the repositioning of malpositioned implants 10.
53
54
55 A failed implant site would present reduced bone volume (horizontally and vertically) that
56
57 would increase the difficulty for resolving such clinical problem. Traumatic implant removal
58
59
60 would further complicate the accomplishment of prosthetic rehabilitation with satisfactory
61
62 3
63
64
65
function and esthetics. It would also increase the risk for vascular injury with important
1
2 consequences if occurs in the floor of the mouth. For that, it is important to perform minimally
3
4
5 invasive implant removal not only for conserving the available bone and gingival tissues but
6
7 also to permit the identification and diagnosis of pathological lesions 11.
8
9
10
11
Different techniques have been reported to explant a failed dental implant that include block
12
12
13 resection, buccal bone osteotomy, and trephine osteotomy . However, these techniques
14
15 require the protection of neighboring tissues and may need the application of regenerative
16
17
18 techniques to restore the surgical area. Consequently, immediate placement of dental implants
19
20 would be jeopardized and cost and time necessary to complete the treatment will increase. In a
21
22
23 recent study a minimally invasive implant removal is achieved by a circumferential osteotomy
24
25 performed with piezosurgery 13.
26
27
28
29
30
31
32 The majority of technique available to remove failed implants does not allow to quantitatively
33
34 measure the force necessary to remove the implant. For that, in this study, a conservative
35
36
37 implant explantation is performed by the application of counter-torque to break the implant-
38
39 bone union. The failed nonmobile implants are analyzed to retrieve data about implant type,
40
41
42
surface treatment, cause for implant removal, and the removal torque. The effect of surface
43
44 treatments on the cause for implant removal and removal torque is analyzed.
45
46
47 Materials and methods
48
49
50
51
52
53
54 Patients were treated between March, 2010 to March, 2014 for dental implant removal. The
55
56 inclusion criteria were:
57
58
59
60  Patients aged over 18 years.
61
62 4
63
64
65
 Explantation of at least one nonmobile implant.
1
2
3
 Identification of the indication for explantation.
4
5  Recording of the removal torque.
6
7
8
9
10 Patients/implants that did not meet any of these criteria were excluded from the study.
11
12
13 Prior to surgery and in order to make a proper treatment plan, all patients underwent standard
14
15
16 diagnostic protocol consisting of reviewing the medical and dental history, diagnostic casts, and
17
18 radiographic evaluation.
19
20
21 Surgical procedure
22
23
24
25 Patients received 2 g of amoxicillin (600 mg of clindamycin for allergic patients) and 1 g of
26
27 acetaminophen 60 minutes before surgery. Local anesthesia was achieved by inferior alveolar
28
29
30
nerve block anesthesia and buccal and/or lingual infiltration anesthesia using articaine
31
32 hydrochloride with epinephrine (1:100,000). A crestal incision was practiced to elevate a full
33
34 thickness flap and expose the surgical site and peri-implantitis was classified according to the
35
36
37 status of surrounding bone 14, 15 into:
38
39
40 Class I: Slight horizontal bone loss with minimal peri-implant bone defect.
41
42
43
44
Class II: Moderate horizontal bone loss with isolated vertical defect.
45
46
47 Class III: Moderate to advanced horizontal bone loss with broad circular bony defect.
48
49
50 Class IV: Advanced horizontal bone loss with broad circumferential vertical defect as well as
51
52
53 loss of oral and/or vestibular bony wall.
54
55
56 However, the extraction of malpositioned implants could be performed without the reflection of
57
58 a mucoperiosteal flap if no implants would be inserted. Implant explantation was carried out
59
60
61
62 5
63
64
65
using an extraction kit (BTI Biotechnology Institute, Vitoria, Spain). For that, a ratchet was
1
2 first engaged into the implant connection (Figure 1). The choice of the insert was based on the
3
4
5 recommendations of the manufacturer although in some cases the insert was shortened using a
6
7 cutting disk for better retention. The removal torque was exerted by a wrench in counter-
8
9
10 clockwise direction maintaining a perpendicular position of the assembly in relation to the
11
12 implant platform (Figure 1). Only in cases where the torque wrench opened (the maximum of
13
14
15
wrench torque was set at 200 Ncm), the extraction assembly was removed and specialized
16
17 trephine burs were employed to cut into the first 3-4 mm of implant-bone contact (Figure 2).
18
19 The implant explantation was then continued with the torque wrench. For all cases, the
20
21
22 removal torque was registered in the patient's record.
23
24
25 The explantation socket was carefully examined to identify abnormalities and the status of the
26
27
28 bony walls. The socket was carefully curetted to remove any granulation tissue. The decision
29
30 for immediate implant placement was based on the design of the prosthesis and the possibility
31
32 to achieve primary stability of the implant. The insertion of the dental implant was done with a
33
34
35 surgical motor at an insertion torque of 25 Ncm and then continued manually to finish the
36
37 implant placement.
38
39
40
41 The low-speed drilling and the design of the bone drills permitted the collection of bone
42
43 particles during the preparation of implant site. The harvested autologous bone was stored in
44
45
46
the fraction 2 of the PRGF-Endoret (BTI; Vitoria, Spain) until use. This resulted in the
47
48 formation of a fibrin clot that glued together the autologous graft particles. Fibrin-glued bone
49
50 graft was applied to fill the gap between implant and bone. Fibrin membrane, prepared from F1
51
52
53 of PRGF, was compressed to provide thin and consistent membrane that was then applied to
54
55 cover the surgical site before flap reposition and suturing (interrupted suture) with
56
57
58 monofilament 5/0 nylon suture. Postoperatively, patients were instructed to perform light and
59
60
61
62 6
63
64
65
gentle brushing of the tooth/structures close to the surgical area after 24 h and to avoid chewing
1
2 on the operated site.
3
4
5
6 To obtain plasma rich in growth factors (PRGF), peripheral blood was extracted by
7
8 venipuncture into four 9 mL extraction tubes containing 3.8% sodium citrate (BTI
9
10
11
Biotechnology Institute S.L, Vitoria, Spain) and processed according to the manufacturer
12
13 instructions. Fifty µl of calcium chloride solution (PRGF activator; BTI Biotechnology Institute
14
15 S.L, Vitoria, Spain) per each milliliter of plasma were employed to activate platelets and fibrin
16
17
18 formation.
19
20
21 Postoperative phase:
22
23
24
25
Follow-up visits were scheduled to remove sutures and to detect any surgical complications.
26
27 Clinical evaluation and implants status were also monitored. After at least 4 months, a second
28
29 surgery was then performed to connect transepithelial abutments (Multi-Im, BTI, Vitoria,
30
31
32 Spain). Success or failure of osseointegration was annotated in the patients records.
33
34
35 Data collection and statistical analysis
36
37
38 The patient was the statistical unit for the description of demographic data. Mean and standard
39
40
41 deviations were calculated for the age variable while relative frequency was calculated for the
42
43 gender. The implant was the statistical unit for the statistical description of indication for
44
45
46 implant removal, location, removal torque, and manufacturer (surface treatment). Mean and
47
48 standard deviation were calculated for torque values. Relative frequency was calculated for
49
50
51 indication for implant removal, implant location, and surface treatment.
52
53
54 Shapiro-Wilk test was performed to evaluate if the data of insertion torque. Kurskal-Wallis test
55
56 was perofmed to detect the staitistical significant of the effect of surface treatments on the
57
58
59 removal torque. Mann-Whitney test was applied for pairwise comparison between the surface
60
61
62 7
63
64
65
treatments. The statistical significance was set at p < 0.05. All the statistical analyses were
1
2 performed using the SPSS v15.0 for Windows statistical software package (SPSS Inc.,
3
4
5 Chicago, IL, USA).
6
7
8
9
10
11 Results
12
13
14
15 This study reports the data of 81 patients with 158 nonmobile implant explantations which
16
17 fulfilled the inclusion criteria. All patients received periodontal cleaning sessions and oral
18
19
20 hygiene instructions before surgery (Figure 3).
21
22
23 Fifty six patients were females and the patient's mean age was 62 ± 11 years (range: 34-81
24
25 years). Seventy nine (50%) implant explantations were performed in the maxilla and 35.3%
26
27
28 were in the anterior sectors. The main cause for implant explantation was peri-implantitis
29
30 (Figure 4; 131 implants; 82.9%) followed by mal-positioning of the implants (22 implants;
31
32
33 13.9%). One implant was extracted due to fracture of prosthetic components and 2 were
34
35 transitional implants. Another 2 implants were affected by bisphosphonate-related
36
37
38
osteonecrosis of the jaws (BRONJ).
39
40
41 The peri-implantitis was classified according to the classification proposed by Jovanovic and
42
43 14, 15
Spiekermann . Periimplantitis Class III affected 28 implants and class IV affected 103
44
45
46 implants.
47
48
49 Implant type: The removed implants were classified according to the surface treatments into
50
51
acid etched, particle blasted, particle blasted + acid etched, oxidized, titanium plasma sprayed,
52
53
54 and turned implants. One implant was hydroxyapatite coated. Most of the implants removed
55
56 were acid etched (47.5%) and oxidized (19.6%) as shown in table 1.
57
58
59
60
61
62 8
63
64
65
Removal torque: The implant removal technique followed in this study allowed the registration
1
2 of the torque necessary to remove the implant. The explantation of 139 implants were
3
4
5 performed without the need for trephine burs. The removal torque of these explantations was
6
7 146 ± 5 Ncm. However, The use of trephine burs was necessary in 19 explantations and the
8
9
10 removal torque was 161 ± 13 Ncm. The indications of using trephine bur were an initial
11
12 removal toque higher than 200 Ncm (15 implants), fractured implants (3 implants) and
13
14
15
fractured prosthetic component (one implant).
16
17
18 The torque necessary to break the implant-bone union showed variations between the different
19
20 surface treatments. The torque value distribution according to the type of surface treatments did
21
22
23 not follow the normal distribution (Shapiro-wilk test, P < 0.05). The Kruskal-Wallis test
24
25 showed the presence of statistically significant effect of surface treatments on the removal
26
27
28 torque (P = 0.000). The pairwise comparison was then performed through the application of
29
30 Mann-Whitney test (Table 2). The removal torque was lower (statistically significant) for
31
32 titanium plasma sprayed implants on comparison with the other surface treatments. The
33
34
35 removal torque was the highest (statistically significant) for acid etched and particle blasted
36
37 implants.
38
39
40
41 Periimplantitis was the cause of removal of all implants that were titanium plasma sprayed.
42
43 This was also the case of more than 80% of the acid etched, particle blasted and oxidized
44
45
46
implants. About 44% of particle blasted + acid etched implants and 67% of turned implants
47
48 were extracted due to periimplantitis.
49
50
51
52
53
54 Complications: Fracture of 3 implants were reported and the extraction of the implants was
55
56 continued with a trephine burs (Figure 5). The implants were from Noble Biocare, Astratech
57
58
59
60
61
62 9
63
64
65
and Biomet 3I. Post-operative recovery was eventful and pain due to surgical intervention was
1
2 successfully managed with oral analgesics.
3
4
5
6 Post-explantation alveolous: After the removal of the implants, the granulation tissue was
7
8 carefully removed and the bony walls were examined with a dental probe. Indentation of
9
10
11
implant's threads was observed to be printed on the alveolar walls indicating the minimally
12
13 invasiveness of the technique. Immediate implant placement was achieved with adequate
14
15 primary stability in 13 cases (Figure 6). Extensive bone resorption and/or the absence of buccal
16
17
18 plate of the alveolous were managed by socket grafting with PRGF clot prepared from F2 that
19
20 was covered with fibrin plug prepared from F1. The new implant placement was performed in a
21
22
23 second surgery after 4 months of bone healing (Figure 7). Worth to mention, the soft tissue
24
25 closure of the defects in patients affected by BRONJ was successfully achieved.
26
27
28
29
30
31
32 Discussion
33
34
35 Different methods have been described to remove osseointegrated dental implants. Some of
36
37
38
them include trephining a bone block in which the dental implant is present, the use of thin bur
39
40 at low speed with irrigation to separate the implant from the surrounding bone and In 2004,
41
42 Massei et al. reported the induction of a localized thermonecrosis at the bone-implant interface
43
44
45 through the application of an ultrahigh frequency electrosurgical device 16. These methods have
46
47 the limitation of being traumatic and of jeopardizing the explantation socket for future implant
48
49
50 placement. Less invasive techniques like counter-ratchet technique and reverse screw technique
51
52 have been developed to preserve available hard and soft tissue.
53
54
55
56
57 In this study the main cause for implant removal was advanced stages of bone loss due to
58
59 periimplantitis. This was the case of all titanium plasma sprayed (TPS) implants and of more
60
61
62 10
63
64
65
than 80% of acid etched, particle blasted and oxidized implants. However, it was lower for
1
2 particle blasted + acid etched implants. This could be related to the fact that most of the
3
4
5 implants included in this study was acid etched and oxidized implants. Additionally, rough
6
7 surface implants (TPS) are more likely to develop periimplantitis than minimally rough
8
9
10 implants once exposed to the oral environment 17. Most of the peri-implant bone defects due to
11
12 periimplantitis showed advanced horizontal bone loss with broad circumferential vertical bone
13
14
15
defect and the loss of at least one bony wall.
16
17
18
19 The explantation method followed in this study allowed the registration of the torque necessary
20
21
22 to remove the implant without damaging the implant surface. This latter could serve to study
23
24 long term changes to the surface of implants after being in function in the oral cavity. The
25
26
27 removal torque was significantly higher for acid etched, particle blasted and oxidized implants.
28
29 However, the removal torque is influenced by several factors like hosting bone quality, design
30
31 18-22
32
of the implant (cylindrical or screw-like), diameter of the implant and surface roughness .
33
34 The counter torque needed to unscrew the implant fixture was below 200 Ncm for 139
35
36 implants. But, the use of trephine bur was only needed when the torque value was higher than
37
38
39 200 Ncm (15 implants).
40
41 Biomechanical studies have shown that the majority of stress transmitted to the peri-implant
42
43
44 bone is concentrated at the crestal bone (the first 2 to 3 mm of implant length) regardless of the
45
46 23-26
implant design , making this area essential to achieve primary implant stability. This has
47
48
49 motivated us to limit the use of trephine bur to break the implant-bone contact at the first 2-3
50
51 threads of the implant. This reduced the removal torque and permitted implant explantation to
52
53
54
be continued with the use of counter-torque wrench.
55
56
57
58
59
60
61
62 11
63
64
65
The principle mechanism of implant explantation was the application of a shear stress to break
1
2 the union between the implant and the bone and allow for implant un-screwing. The result was
3
4
5 atraumatic implant explantation and preserving at maximum the available hard and soft tissues.
6
7 Thus, immediate implant placement was possible in 13 cases which avoid the need for tissue
8
9
10 regeneration before implant placement, reducing the time and cost. Postoperative recovery of
11
12 the patients was uneventful and pain was successfully managed by oral analgesics.
13
14
15
16
17 This study suffers from the limitation of absence of control group where implants have been
18
19 explanted by different technique. The time period between implant insertion and explantation
20
21
22 could not be calculated for the majority of the removed implants as these implants were placed
23
24 in another clinical centers. More conservative approach than implant explantation to treat
25
26
27 periimplantitis could not be followed as significant bone loss has already progressed.
28
29
30
31
32
The protocol followed in this study could constitute a real alternative to other traumatic
33
34 technique for the removal of failed implants. The conservation of available hard and soft tissues
35
36 is possible and permitted resolving implant failure at shorter time and cost by avoiding
37
38
39 advanced tissue regeneration techniques.
40
41
42
43 Conclusions
44
45
46
47 Periimplantitis and malpositioning of the implants were the main causes for implant
48
49 explantation. Periimplantitis was the only cause for the explantation of titanium plasma sprayed
50
51
52 implants. The application of shear stress at the implant-bone contact was effective to permit
53
54 atraumatic implant explantation. The removal torque was higher for acid etched, particle
55
56
57
blasted and oxidized implants. The technique preserved at most the available bone tissue and
58
59 reduced the need for advanced tissue regeneration procedures.
60
61
62 12
63
64
65
1
2
3
4
5 References
6
7
8 1. Nogueira-Filho G, Iacopino AM, Tenenbaum HC. Prognosis in implant dentistry: a
9
10 system for classifying the degree of peri-implant mucosal inflammation. J Can Dent Assoc.
11
12
13 2011; 77: b8.
14
15 2. Tenenbaum HC, Glogauer, M., Lanzberg, M., Goldberg, M. Systemic implications of
16
17
18 peri-implant inflammation; mimicry of the periodontitis systemic disease model? In: Jokstad A,
19
20 ed. Osseointegration and dental implants. 1st ed. Toronto, Wiley Press; 2008: 74-84.
21
22
23 3. Esposito M, Grusovin MG, Coulthard P, Thomsen P, Worthington HV. A 5-year
24
25 follow-up comparative analysis of the efficacy of various osseointegrated dental implant
26
27
28
systems: a systematic review of randomized controlled clinical trials. Int J Oral Maxillofac
29
30 Implants. 2005; 20: 557-568.
31
32 4. Wennerberg A, Albrektsson T. Current challenges in successful rehabilitation with oral
33
34
35 implants. J Oral Rehabil. 2011; 38: 286-294.
36
37 5. Anitua E, Orive G. A new approach for atraumatic implant explantation and immediate
38
39
40 implant installation. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012; 113: e19-25.
41
42 6. Sanz M, Chapple IL. Clinical research on peri-implant diseases: consensus report of
43
44
45
Working Group 4. J Clin Periodontol. 2012; 39 Suppl 12: 202-206.
46
47 7. Bidra AS. Surgical and prosthodontic consequences of inadequate treatment planning
48
49 for fixed implant-supported prosthesis in the edentulous mandible. J Oral Maxillofac Surg.
50
51
52 2010; 68: 2528-2536.
53
54 8. Akkad S, Richards M. Solutions for severely angulated implants in the mandibular
55
56
57 overdenture: a clinical report. J Prosthodont. 2009; 18: 342-347.
58
59
60
61
62 13
63
64
65
9. Lee CK, Agar JR. Surgical and prosthetic planning for a two-implant-retained
1
2 mandibular overdenture: a clinical report. J Prosthet Dent. 2006; 95: 102-105.
3
4
5 10. Oduncuoglu BF, Alaaddinoglu EE, Oguz Y, Uckan S, Erkut S. Repositioning a
6
7 prosthetically unfavorable implant by vertical distraction osteogenesis. J Oral Maxillofac Surg.
8
9
10 2011; 69: 1628-1632.
11
12 11. Gerlach RC, Dixon DR, Goksel T, Castle JT, Henry WA. Case presentation of florid
13
14
15
cemento-osseous dysplasia with concomitant cemento-ossifying fibroma discovered during
16
17 implant explantation. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013; 115: e44-52.
18
19 12. Smith LP, Rose T. Laser explantation of a failing endosseous dental implant. Aust Dent
20
21
22 J. 2010; 55: 219-222.
23
24 13. Marini E, Cisterna V, Messina AM. The removal of a malpositioned implant in the
25
26
27 anterior mandible using piezosurgery. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;
28
29 115: e1-5.
30
31
32
14. Jovanovic SA. Diagnosis and treatment of peri-implant disease. Curr Opin Periodontol.
33
34 1994: 194-204.
35
36 15. Spiekerman H. Color atlas of dental medicine. New York, NY: Thieme; 1995.
37
38
39 16. Massei G, Szmukler-moncler S. Thermo-explantation. A novel approach to remove
40
41 osseointegrated implants. Eur Cell Mater. 2004; 7: 48.
42
43
44 17. Lang NP, Berglundh T. Periimplant diseases: where are we now?--Consensus of the
45
46 Seventh European Workshop on Periodontology. J Clin Periodontol. 2011; 38 Suppl 11: 178-
47
48
49 181.
50
51 18. Anil S, Al Dosari A. Impact of bone quality and implant type on the primary stability:
52
53
54
an experimental study using bovine bone. J Oral Implantol. 2013.
55
56
57
58
59
60
61
62 14
63
64
65
19. Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of
1
2 surface characteristics on bone integration of titanium implants. A histomorphometric study in
3
4
5 miniature pigs. J Biomed Mater Res. 1991; 25: 889-902.
6
7 20. Elias CN, Rocha FA, Nascimento AL, Coelho PG. Influence of implant shape, surface
8
9
10 morphology, surgical technique and bone quality on the primary stability of dental implants. J
11
12 Mech Behav Biomed Mater. 2012; 16: 169-180.
13
14
15
21. Ivanoff CJ, Sennerby L, Johansson C, Rangert B, Lekholm U. Influence of implant
16
17 diameters on the integration of screw implants. An experimental study in rabbits. Int J Oral
18
19 Maxillofac Surg. 1997; 26: 141-148.
20
21
22 22. Wennerberg A, Albrektsson T, Lausmaa J. Torque and histomorphometric evaluation of
23
24 c.p. titanium screws blasted with 25- and 75-microns-sized particles of Al2O3. J Biomed Mater
25
26
27 Res. 1996; 30: 251-260.
28
29 23. Anitua E, Tapia R, Luzuriaga F, Orive G. Influence of implant length, diameter, and
30
31
32
geometry on stress distribution: a finite element analysis. Int J Periodontics Restorative Dent.
33
34 2010; 30: 89-95.
35
36 24. Nissan J, Ghelfan O, Gross O, Priel I, Gross M, Chaushu G. The effect of
37
38
39 crown/implant ratio and crown height space on stress distribution in unsplinted implant
40
41 supporting restorations. J Oral Maxillofac Surg. 2011; 69: 1934-1939.
42
43
44 25. Nissan J, Gross O, Ghelfan O, Priel I, Gross M, Chaushu G. The effect of splinting
45
46 implant-supported restorations on stress distribution of different crown-implant ratios and
47
48
49 crown height spaces. J Oral Maxillofac Surg. 2011; 69: 2990-2994.
50
51 26. Pierrisnard L, Renouard F, Renault P, Barquins M. Influence of implant length and
52
53
54
bicortical anchorage on implant stress distribution. Clin Implant Dent Relat Res. 2003; 5: 254-
55
56 262.
57
58
59
60
61
62 15
63
64
65
Figure legends
1
2
Fig.1. Implant removal with counter-ratchet technique. a) clock-wise insertion of the ratchet into the
3
4 implant to extract. b) placement of the wrench to apply a torque in counter clockwise direction for
5
6 implant removal.
7
8 Fig. 2. Removal of the implant if the counter torque exceeds the 200 Ncm. a) deactivation of the torque
9
10 wrench. b) the use of trephine bur to break the first 3-4 mm of implant-bone contact, the insertion of the
11
12 ratchet into the implant, removal of the implant and the insertion of new implant when a good bony
13 support is available.
14
15
16 Fig. 3. a) mal-positioned implants and poor oral hygiene as indicated by the accumulation of dental
17
18 plaque on the implants surface. b) the clinical picture after receiving cleaning and polishing to improve
19 the peri-implant soft tissue. c) and d) implants with bone defects were removed and new implants were
20
21 placed. The 4 implants in the anterior sector and the old prosthesis were maintained as provisional
22
23 prosthesis.
24
25 Fig. 4. a) probing depth of 8 mm around implant supported restoration. b) radiographic evidence of
26
27 advanced peri-implant bone loss. c) the implant removal and a circumferential bone defect. d) the
28
29 removed implant presenting dental plaque accumulation at the threaded implant neck.
30
31 Fig. 5. a) Fracture of the implants at the level of the implant's neck that justifies limiting the maximum
32
33 torque to a value of 200 Ncm. b) higher magnification
34
35 Fig. 6. a) Clinical picture showing the upper removal denture and the lower overdenture. b) Panoramic
36
37 radiograph showing the evidence of bone loss around the implants supporting the lower overdenture. c)
38
39 The advanced bone loss around the implants after the reflection of mucoperiosteal flap. d) the
40 immediate placement of new implants and the placement of transepithelial abutment. e) the provisional
41
42 prosthesis for implant's immediate loading. f) Panoramic radiograph showing the newly placed
43
44 implants.
45
46 Fig. 7. a) the implants after removing the prosthesis, we can note the puss exudate around the most
47
48 mesial implant. b) status of the soft tissue after explantation and placement of new implants. c) the size
49
50 of the bone defect after implant removal indicated the need of regeneration and the deferral of implant
51 placement. d) the bone regeneration by PRGF-Endoret after 4 months were almost complete at #19 and
52
53 bridged about 80% of the defect at #22. e) Panoramic radiograph showing peri-implant bone loss around
54
55 all implants before intervention. f) The new implants supporting a new definitive prostheses.
56
57
58
59
60
61
62 16
63
64
65
Table 1
Click here to download Table: Table 1.docx

Table 1. Surface treatment type effect on the removal torque and frequency of
periimplantitis as cause of implant removal.

Surface Frequency Removal torque (Ncm) Periimplantitis


treatment Without With combined
Trephine bur Trephine bur
acid etched 75 155 ± 46 152 ± 32 155 ± 45 68 (90.6%)
particle blasted 18 174 ± 59 150 ± 50 170 ± 57 16 (88.9%)
particle blasted + 16 94 ± 54 200 ± 71 107 ± 65 7 (43.8%)
acid etched
oxidized 31 150 ± 44 158 ± 74 152 ± 50 25 (81%)
titanium plasma 11 89 ± 63 100 90 ± 60 11 (100%)
sprayed
turned 6 150 ± 30 - 150 ± 30 4 (66.7%)
Table 2
Click here to download Table: Table 2.docx

Table 2. Statistically significant (P < 0.05) pairwise comparisons of the effect of surface
treatment on the implant removal torque.

Group 1 Group 2
Acid etched particle blasted + acid
etched
titanium plasma sprayed
particle blasted particle blasted + acid
etched
titanium plasma sprayed
particle blasted + acid titanium plasma sprayed
etched
oxidized titanium plasma sprayed
Figure 1
Click here to download high resolution image
Figure 2
Click here to download high resolution image
Figure 3
Click here to download high resolution image
Figure 4
Click here to download high resolution image
Figure 5
Click here to download high resolution image
Figure 6
Click here to download high resolution image
Figure 7
Click here to download high resolution image
Cover Letter
Click here to download Cover Letter: Coverletter.docx
Copyright Form
Click here to download Copyright Form: copyright.pdf

Potrebbero piacerti anche