Sei sulla pagina 1di 1

CALCULO DE ILUMINACION INTERIOR

DATOS: CALCULO
5- FACTOR DE MANTENIMIENTO
a =___________ 1- SUPERFICIE “S”
BUENO
S = a x b = ____________=_____________ ɱ = ________ [TABLA] MEDIO
b =___________ PESIMO
2- ILUMINACION “E” (TABLAS)
6- HALLAR EL FLUJO TOTAL “ ∅ 𝑇𝑂𝑇 “
H =___________
E=____________
𝑆×𝐸
∅ 𝑇𝑂𝑇 = = _________ =________
3- HALLAR INDICE DE LOCAL “K”
µ×ɱ
h’=___________

H = h + h’ + h‘’ 7- HALLAR EL NUMERO DE LAMPARAS

Techo =_______ ∅𝐿𝑎𝑚𝑝 (Tabla, Según Dato)


h = H – h’ =__________ = __________

𝑎×𝑏 ∅
Pared =_____________________ K=
ℎ (𝑎+ 𝑏)
= __________=___________ 𝑁𝐿𝑎𝑚𝑝 = ∅ 𝑇𝑂𝑇 = _____________
𝐿𝑎𝑚𝑝
3𝑎 × 𝑏
K= = __________=_________
Lampara =___________________ ℎ+ℎ"(𝑎+ 𝑏) 𝑁𝐿𝑎𝑚𝑝 =________
8- HALLAR EL NUMERO DE CENTROS DE LUZ

Mantenimiento = ______________ 4- HALLAR EL FACTOR DE UTILIZACION “µ” 𝑁𝐿𝑎𝑚𝑝 𝑁𝐿𝑎𝑚𝑝 𝑁𝐿𝑎𝑚𝑝


DE TABLA [MANEJO DE TABLA] 𝑁𝐶𝐿 = ; ;
1 2 3

Nivel de Iluminación =____________ µ =________________ 𝑁𝐶𝐿 = ____ ; _____ ; ______