Sei sulla pagina 1di 2

Flush End Plate Moment Conn.

DAR AL-HANDASAH DESIGN OF MOMENT CONNECTION


SHAIR&PARTNERS Flush End Plate Moment Connection
Project Prepared by Dr.Hany El-Rashidy/Eng.Walaa El-MohandComputed by:
Building Checked by
Subject Approved by

Reference BS 449 Part 2

Section Dimensions

H (Total) t (web) B (fl.) t (fl.)


cm

Straining Actions

Moment (m.t
Shear (t.)Tension (t.)

FY= 2.45 t/cm2 Normal Grade

Check No. and Diameter of Bolts:

NO.OF BOLTS/COL.= 2.00 bolt (up to 10 col's.)


NO.OF BOLTS/ROW.= 4.00 bolt 2 Bolts
4 Bolts
Y1= 6.00 cm I1= -6.00 cm ###
Y2= 16.00 cm I2= -22.00 cm ###

I(bolts)= -346.67 cm

T1= 0.00 ton


T2= 0.00 ton

###

416673731.xls 1/2 04/15/2019


Flush End Plate Moment Conn.

MAX.TENSION FORCE/BOLT= 0.00 ton Grade (8.8) - D


MAX.SHEAR FORCE/BOLT= 0.00 ton
###
USE BOLTS = M24 Grade (10.9) - DIN 6914 - No Torque Tightened M16
F all.ten. (No Torque T.) = 14.47 ton M20
F all.ten. (With Torque T) = 15.40 ton M22
F all.shear = 8.80 ton M24
M27
U.C due to tension = 0.00 < 1 (safe) M30
U.C due to shear = 0.00 < 1 (safe) M36
E70XX
Calculation of Welding Size: E60XX

Allowable weld stress


Electrode specificatio E70XX
Tensile strength = 3.48 t/cm2
f all. = = 0.3*nominal tensile strength of weld metal
1.04 t/cm2
= 0.4*yield stress of base metal
0.98 t/cm2
f all. = 0.98 t/cm2
TENSION FOR FLANGE = #DIV/0! ton
TOP FLANGE WELD SIZE= #DIV/0! cm

Sw(min.) = #DIV/0! mm.

Calculation of End Plate Thickness:

Check on the first bolt in the same row:


g= 0.00 cm
Sw. web = 0.00 cm
m'' = 0.00 cm
2*m''*(3)^0.5 = 0.00 cm
pitch P = 0.00 cm
V' = 6.00 cm
dq = LESS(P/2+V' AND P/2+ m''*3^0.5)

dq = 0.00 cm

Thickness of Head Plate Te= #DIV/0! cm

T1= #DIV/0! mm

Check on the second bolt in the same row:


g1 = 0.00 cm
m=m''+g1 = 0.00 cm
2*m*3^0.5 = 0.00 cm
dq = Min. P/2+V' AND P/2+ m''*3^0.5)
dq = 0.00 cm

Thickness of Head Plate Te= #DIV/0! cm


T2= #DIV/0! mm

Te (final) = #DIV/0! mm

416673731.xls 2/2 04/15/2019