A) Wind data:
Step-2 : PV Elite Input : Shape Factor Input in PV Elite- Configuration Tab /Job specific setup param-
eters :
De= (OD + [2 x Ti]) + (Ladder width [300mm]) + (Platform) + (Pipe O.D. + [2 X Pti])
OD (m) = Outside diameter
ALL RIGHTS RESERVED
THIS DOCUMENT AND ANY DATA AND INFORMATION CONTAINED THEREIN ARE CONFIDENTIAL AND THE PROPERTY OF L&T CHIYODA LIMITED (LTC) AND THE COPYRIGHT THEREIN IS
VESTED IN LTC NO PART OF THIS DOCUMENT, DATA, OR INFORMATION SHALL BE DISCLOSED TO OTHERS OR REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WHATSOEVER,
EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF LTC.
4404
Rev.
Page 6 of 8
00
Please check & ensure Seismic Scalar Multipliers in PV-Elite or other renowned software (Scalar factor
is 1.0) & Inform to Purchaser in loading data.
DBE CASE:- Consider for 2% Damping (Do not select “Design Basis for Earthquake load is MCE?”)
MCE CASE:- Consider for 4% Damping (Select “Design Basis for Earthquake load is MCE?”)