75,0 mm
SUPPLY
OUTPUT
OFFSET ZERO
FREQUENCY MEASURING
TRANSDUCER
VOLT 5V
10mA
10V
Type: FAMA
mAMP 20mA
NO OFFSET
+ - A1 A2
35,0 mm 100,0 mm
105,0 mm
FEATURES Description:
The transducer type FAMA is used to measure the frequency of an
input voltage. The output is a load independent DC voltage or current
• High input resistance signal. The input can be connected directly or via transformers.
• Low response time
• Excellent linearity Operation:
• All ranges class 0.5 according to EN60688. The input voltage is transformed to a suitable signal level. At each
zero-crossing the input creates a rectangular pulse with a constant
• 8 outputs available height and width. The pulse train, with a frequency proportional to
• Isolation > 4kV. Input, output and supply. that of the input voltage, is filtered and in amplifier converted to a
load independent DC output. The input voltage can also be used
• All standard AC voltages for power supply. as supply voltage. The supply voltage is galvanically separated by
Optional combined AC and DC supply. the plug-in transformer.
Applications:
Instrumentation, PLCs, PC and microprocessor control systems .
FUNCTION DIAGRAM
AC Supply AC/DC Supply
AC supply Supply
Isolation Isolation
=
˜=
A2
˜=
A2 Supply
Supply
A1 A1 =
AC input AC input
B2 B2 +
Input
˜=
+ DC output
-
Input
B1 ˜= -
DC output
{
B1
Signal
Isolation {
Output
Signal
Isolation Output
OUT
OUT
0 - 10 mA
2 - 10 mA
IN 0 - 20 mA
IN
4 - 20 mA
0 - 5V
1 - 5V
Output: 0 - 10 mA, 0 - 20 mA Output: 2 - 10 mA, 4 - 20 mA
0 - 10 V
0 - 5 V, 0 - 10 V 1 - 5 V, 2 - 10 V
2 - 10 V
CONNECTION DIAGRAM
Rail mounting Socket mounting
B1 B2
6
5 7
B1 B3
4 8
FAMA 3 9
2 10
+ - A1 A2 1 11
A1 + - A2
Output Supply
77
SUPPLY VOLTAGE
GENERAL 18-360 VDC and 20-264VAC E400
Temperature range - 25 °C to + 55 °C 20-28 VAC B024
Humidity Up to 90 % RH non-condensing 99-140 VAC B110
Dielectric test voltage Input to output 4000 VAC 198-264 VAC B230
Input to supply (internal) 4000 VAC 342-484 VAC B400
Output to supply (internal) 4000 VAC 352-576VAC B460
Weight 0.20 kg with internal supply
OUTPUT
Programmable with dipswitch D
0 - 10 mA, 2 - 10 mA,
International Standards 0 - 20 mA, 4 - 20 mA,
EMC directive 89/336: EN50081 - Emission 0 - 5 V, 1 - 5V
EN50082 - Immunity 0 - 10 V, 2 - 10 V
Low voltage directive 73/23: EN60255 - Electrical Relays
EN60688 - Measuring transducers HOUSING
Rail mounting with internal supply A
Socket 11 pin with internal supply E
SIZE
35 mm. 3
CODE
Code end C
Extended code E
78
We reserve the right to make changes for product improvement. FAMA.indd - 241114