Sei sulla pagina 1di 4

NO DESCRIPTION SYMBOL

A Fire Tube Boiler General Data


1 Working Pressure PW
Working Temperature v
2 Safety Factor X
B Drum's Calculation
1 Material SA-515 70
2
Tensile Strength SB

3 Inside Diameter Di
4 Actual Thickness tA
5 Joint Efficiencies Z
6 Factor Annealing C
7 Additional Allowance ∆
8 Type of Heat Transfer a
9 Yield Point at Room Temperature

12 Yield Point at Working Pressure

13 Minimum Required Thickness

C Pipe's Calculation
1 Material SA-209 Ti
2 Yield Point at Room Temperature SV
3 Diameter of pipe d
4 Actual Thickness tA
5 Additional Allowance ∆
6 Type of Heat Transfer a

Yield Point at Working Pressure


7

Minimum Required Thickness


8

9 Permitted Range Between Pipe a

D Tube plate Calculation


1 Min.Required Thickness of tube plate t1

AB
CD
AD
CB
b1

b2

t2

E Furnace Calculation
Diameter of furnace D
Length of furnace L
a
C

y
FORMULA RESULT UNIT

Data 6 Kg/cm2
Table Saturated 164.4 oC
1.5

70,000 Psi OR
49.21 Kg/mm2
Data 2,150 mm
12.5 mm
80 %
5%
1 mm
Conduction 0 oC

27.3389

0.90194

24.6581

6.24431 mm

21.10 Kg/mm2
Data 76.10 mm
3.2 mm
0.5 mm
Radiation 75 oC

0.79206

16.7126

0.70436 mm

96.9714 mm
14.5125 mm

280
390
220
230
335

225

285.455

table 54

13.9485 mm

1130 mm
2930 mm
Radiation 75
Table 9

1.14854

0.79206

21.6541

13.0525 mm

Potrebbero piacerti anche