Alarm Type Event Type

Unavailable STSLB Threshold Critical (412)


Unavailable STSLB Threshold Major (411) Logical alarms
Unavailable STSLB Threshold Minor (410)
Unavailable ABIS TCH Threshold Major (165)
Logical alarms
Unavailable ABIS TCH Threshold Minor (164)

Unavailable Radio Signalling Channels Threshold Minor (102)


Logical Alarm

Functionality Lost (247) Logical Alarm


No Call in Cell within a Predefined Time Frame (66)
Logical Alarm

BTSM Failed Alignment (179)


Logical Alarm

Edge Support Lost in Cell (369) Logical Alarm


LAPD link protocol failure (12318) Logical Alarm
FANP: unit failed (53278)
Equipment alarm

DUAMCO: RX alarm LOW (53256)


Equipment Alarm

RACK: door open (53277) Sensor problem


Alarm Description Alarm clearing guidelines
Subslot problem of TS on PCM creation 1. Check TS creation on database
or subslot still not created

TCH was blocked or disable 1. Check from TRX alarm ( CU fault or CU was locked )
2. Check from DUVSWR alarm ( fault or locked )
3. Check from TRX part on database ( locked )
TS was blocked or disable which has 1. Check from TRX alarm ( CU fault or CU was locked )
been defined as signalling channel 2. Check from DUVSWR alarm ( fault or locked )
3. Check from TRX part on database ( locked )
BTS or Site was down 1. Check the corresponding BTS/site
No call or FDUAMCO can not transmit 1. Make a Hard reset for the corresponding FDUAMCO
its power correcly 2. Replace the corresponding FDUAMCO
E1 or BTS was down and no alignment 1. Check the corresponding E1 connection
between BTSE and BSC 2. Check the TEI setting of BTSE
No EDGE module on the cell or locked 1. check the EDGE module in the corresponding cell
E1 problem ( signalling part ) 1. Check the corresponding E1 connection
Equipment error 1. Test the module by using perftest command from LMT
2. Make a Hard reset by pulling out the module
3. Replace the corresponding FANP
Receiver part has problem 1. Test the module by using perftest command from LMT
2. Swap the corresponding jumper cable to the unused port
3. Replace the corresponding FDUAMCO
Rack door was opened or was not 1. Close the door properly
closed properly 2. Make a short connection to deactivate this alarm
Alarm Type Alarm Description
The RF part of the CU has problems (34835) Tranceiver problem ( Radio Frequency part)

Hardware Error on CU detected by BIC (20603) Equipment Failure


(Power supply unit does not work correctly)

Hardware error (4110) Equipment Failure

Test Result failed (28675) Equipment Failure


( The initiated perftest or automatic test failed )

RF power reflected into powerstage (34892) Equipment Failure


(Poweramplifier detects reflected RF power)

Any of the PLLs shows lockproblems (34836) Equipment Failure


(Phase Locked Loop (PLL) has problem )

Fatal HPI-DD error (41040) Communication error

Device driver initialization failed (94) Equipment Failure

No startup-request after reset (24603) Processor Problem


(Reset Supervision Failed)

Loss of board (22536) Equipment Failure


( The CORE can not detect the module )

diversity receive branch failed (34837) Receiver Failure


( Bad signal receive level or bad signal to noise
ratio in the receiver path )

No Call in TRX within a Predefined Time Frame (70) Tranceiver problem


(The CU can not carry traffic or desert area
which is nobody make a call during predefined
time )
Critical SELIC problem (8260) ( new) Equipment Failure
(SELIC indicates a critical problem or illegal CC
link configuration
Alarm clearing guidelines
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Make a Hard reset by pulling out the module
4. Replace the module
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Make a Hard reset by pulling out the module
4. Replace the module
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Make a Hard reset by pulling out the module/switching off-on the breaker
4. Replace the module
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Make a Hard reset by pulling out the module/switching off-on the breaker
4. Replace the module
1. Check the corresponding cable/connection
2. Test the module by using perftest commad from LMT
3. Move Tx cable to the idle port of FDUAMCO
4. Swap FDUAMCO with another which has an unused feeder port
5. Replace the module
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Replace the module
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Move/swap the module to another slot
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Make a Hard reset by pulling out the module/switching off-on the breaker
4. Replace the module
1. Test the module by using perftest commad from LMT
2. Try to delete and create it again
3. Make a Hard reset by pulling out the module
4. Replace the module
1. Try to delete and create it again
2. Make a Hard reset by pulling out the module
3. Check the back panel
4. check the CC link cable between Rack#0 and Rack#1
5. Move the module to another unused slot
1. Test the corresponding DULNA which is connected to the CU
2. Check the corresponding Rx cable/connection between CU and DULNA
3. Move the corresponding jumper cable to the unused port of FDUAMCO
4. Swap FDUAMCO with another which has an unused feeder port
1. Test the CU which is related to this TRX
2. Replace the module

1. Check the CC link cable between Rack#0 and Rack#1


2. Move the corresponding CU to another slot
3. Reset the COSA by making perftest by Software