Calculation of Induction Motor Starting


Parameters Using MATLAB

Dejan Pejovski, Bodan Velkovski


“Ss. Cyril and Methodius” University in Skopje
Faculty of Electrical Engineering and Information Technologies
Skopje, Republic of Macedonia

16 – 18 March 2016
Induction Motors

• 67 – 87% of all installed AC drives


• Home and industry applications
• Low production and maintenance costs
• Wide power range
• Reliable operation

Motor loads: pumps,


fans, compressors,
mills, cranes…
Methods of Starting an Induction Motor

• Direct starting - for small motors;


- large starting current Ip=(6-8)In
- small starting torque Mp  U1f2
- large voltage drop (<10%)

• Wye-delta starting
• Stator resistance starting
• Autotransformer starting
• Soft starting
Torque – Speed Curves
Končar VAAZ A 800-A L260L720 M100B14P0,9 fan: Pn=1.05 kW, nn=720 min-1

Končar 5AZ 100LB-8 motor. Mk=36.01 [Nm] Sever ZK 100 Ld-8 motor. Mk=33.98 [Nm]
Pn=1.1 kW
Motor Ip/In Mn [Nm] Mp/Mn Mk/Mn Jm[kgm2] m [kg]
Končar 3.7 15 2.1 2.4 0.0104248 23
Sever 3.5 15.5 2 2.2 0.0127 34.6
Starting Time Calculation

Torque equilibrium
d
Mm  Ms  Md  Ms  J
dt
2M k
Mm 
s sk

sk s

2
 n 
M s  M sn   
 nn 
n0
mD 2
tp  
0
38,2M m  M s 
dn
Starting Time Calculation
Simpson’s 3/8 rule for numeric integration :
-based upon a cubic interpolation
-twice as accurate as the standard parabolic method

a) Koncar motor: tp = 0.0387 s b) Sever motor: tp = 0.098 s

Longer starting time because of the greater starting torque


Energy Losses During Starting Time
n0 2 n0
mD

Mm
n0  ndn
2
Mm

mD 
Arot  n0 dn ACu 2
Mm  Ms
365 Mm  Ms 365
0
0

a) with one stator winding; b) Dahlander’s winding speeds in ratio 1:2;


c) continuous speed change

Motor Acu2[kJ] Ak [kJ] Arot [kJ]

Končar 5AZ 100LB-8 34.207 15.7 49.915

Sever ZK 100 Ld-8 43.45 39.159 82.61


Winding Temperature During Starting Time
 
t  
t
  mc
   m 1  e TZ    o e TZ
TZ   10 min
 Sh
 

Končar motor: 92.89 oC Sever motor: 92.59 oC

• Duty cycle S1
• Totally enclosed and fan cooled motors
• Insulation class F -> allowed temperature 100 oC
Conclusion

Criteria for choosing adequate induction motor:


1. Rotor energy losses during starting time
(energy efficiency is important)
2. Starting time value
3. Winding temperature (because of insulation
endurance)
Thank you for your attention