Sei sulla pagina 1di 4

T r i o s L u m i n a i r e s

The simplest way to lighting control

Movement detection with Light sensor for constant lux and daylight-link control

absence timer Trios Luminaires are initially set to maintain a nominal 500 lux on

Trios Luminaires can include movement working areas. Any deviations can easily be corrected with an infrared

sensors to detect when someone walks into a transmitter. In areas with little or no daylight (constant lux mode),

room.The lamp then immediately switches to a preset lux illuminance levels are maintained throughout the system’s

level. When no one is present the lights gently turn down to save maintenance cycle, regardless of lumen depreciation caused by dirt

energy and then switch off if the area remains unoccupied. Lights in accumulation or lamp aging.This eliminates the need for over-lighting

corridors and staircases can be prevented from switching off when and therefore minimises energy wastage. In areas with good daylight,

they are set in the security lighting mode. lux levels are maintained by turning lights down when daylight levels

increase. Lights automatically switch off when the measured lux level

remains above the switch-off level for more than 15 minutes.

Lights switch back on when daylight levels drop below the defined

lux level and if the area is occupied.

Infrared remote control

for user comfort and

commissioning

Handheld and wall-mounted transmitters give users full control over

their lighting system. Lights can be switched from multiple points and

levels can be adjusted, stored and recalled with a four-preset hand

transmitter.
Luxsense

Luxsense luminaires contain a very discrete light

sensor that regulates the light output to a pre-

defined illuminance level of the workplace.

The energy savings thus achieved are based on the

compensation of the over-design effect (maintained

illuminance) and the level of daylight. With today’s increasingly

efficient lamps and optics, a compensation for over-design is


Infrasense
particularly efficient, especially in retrofit buildings. Savings of up to
Infrasense luminaires have all
30% are possible as an average for north/south, corridor/window
lighting control elements
position and summer/winter season.
integrated in the luminaire itself

and consequently the handling

and installation is the same as


Multisense
"normal" luminaires and requires
State-of-the-art "intelligent" luminaires provide the optimal controls
no special training or instruction.
solution. Each luminaire is equipped with a multisensor that can
Furthermore the luminaire can
detect movement for maximum energy saving, a light sensor for
be fully tested in the factory.
daylight linking or constant lux
The luminaire is equipped with
control and a infrared receiver
two control elements: a sensor
for remote control, override
and a controller.The sensor, an
control from a wall mounted
infrared receiver, is usually
transmitter or handheld unit.
mounted on the optic side so that the infrared signals can easily be
The infrared receiver can also
received.The controller is mounted at the base of the luminaire, and
be used for commissioning or
processes the sensor signals. Infrasense is designed for mains
remote programming of light
switching of two separate outputs, providing basic energy saving and,
levels. As a result of combining
most and for all, flexibility of the office layout. Being luminaire based it
all three sensors in each
is particularly suited for retrofit projects.
luminaire, installation time is

therefore minimal, as vertical

switch wires are no longer

needed.
Lighting Controls Trios, luminaire based

LRL 1220
Luminaire-based illuminance
19 sensor for direct control of HF
regulating ballasts. It gradually
reduces the light output of the
luminaire when the illuminance

25
level on the working plane under
the luminaire increases over a
selectable level due to further
Ø 15 increasing daylight.The unit is
connected to the 1-10 V DC
Type Weight (kg) EOC
control input of regulating ballasts. LRL1220/00 0.02 56082799
LRL 1220/00
LRH 1221/00, LRH 1222/00
Lamp clip 'TL'D or 'TL'5 plastic
19 ∅ 24.5 19 ∅ 21 mounting clip, intended to mount
the luminaire based light sensor
LRL 1220 to a 'TL'D or 'TL'S size
fluorescent lamp.
The use of this clip eliminates the
42

35
need for mechanical provisions or
adaptations to the luminaire or
19 the optical system and facilitates
19
easy lamp replacement.

LRH 1221/00 - LRH 1222/00 LRH 1221/00 LRH 1222/00


Type Weight (kg) EOC
LRH1221/00 0.01 56083499
LRH1222/00 0.01 56093399

LLC 1120 adjusted by the installer with an


Luminaire-based controller with infrared transmitter (programming
148 two outputs, for switching-only tool).Thus there is no need to
applications. Suitable for infrared open the ceiling or the luminaire
remote manual control and for commissioning. Alternatively
40

automatic control by means of a the unit is suitable for controlling


movement detector. Centrally the motors of curtains or
controlled switch-off is possible, projection screens. In this
28

using short mains interruptions. application the unit has to be built


159
The mode of operation, group inside an installation cabinet or
and channel addresses and the similar protection.
power-up behaviour can be
LLC 1120/00
Type Weight (kg) EOC
LLC1120/00 2.60 56081000

IRR 1224
Infrared receiver, intended for
luminaire based mounting.
19 19
The receiver can be clipped onto
the lamp using lamp clips LRH
1221 or LRH 1222. Alternatively
the unit can be mounted with a
18 metal bracket (to be provided by
the luminaire manufacturer).
Connection is done with a 1 m.
long connection cable, provided
Type Weight (kg) EOC
with a standard modular plug. IRR1224/00 0.02 51715500
IRR 1224
Lighting Controls Trios, luminaire based

51 LRI 1110
Luminaire-based multi-sensor
incorporating an infrared receiver
for remote control, a light sensor
for ambient light monitoring and

52
a passive infrared detector for
movement detection. It has to be
used in combination with the
LCC 1130/10 controller and is
fitted with cable and plug for

32
connection to the modular input
Type Weight (kg) EOC
socket of the controller. LRI1110/10 0.20 55809100
LRI 1110/10 Dimensions in mm
LLC 1130 fixed.The LLC 1130/10 has to be
Luminaire-based controller for used in combination with the
148 switching high-frequency or luminaire-based multi-sensor
conventional ballasts, with LRI 1110/10.
maximum switching load of 150
VA.The unit has a special output
40

terminal providing the 1-10 V DC


voltage for the control of a
28

maximum of two regulating


electronic ballasts. On the unit a
159 group address (1 out of 7) can be
Type Weight (kg) EOC
selected.The channel address is LLC1130/10 2.90 55818300
LLC 1130/00
LCH 1199
Trios Luminaires Handbook,
assisting consultants, engineers
and installers in the process of
design, installation and
commissioning of lighting control
solutions based on the TRIOS Type
luminaires. LCH1199/00

The Trios system is completed with a selection of the following General Purpose Components.
Infrared transmitters Page
IRT 8060 511
IRT 8065 511
IRT 8070 511
IRT 1090 500
IRC 2130 511

Potrebbero piacerti anche