Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
02/19/2018 All All Change to revision date to match print version, February 2018
3.1 Residential Backup Transfer Switch Solutions
Automatic Transfer Switches
Contents
3 Residential Automatic Transfer Switches
Description Page
3 Automatic Transfer Switches
Standards and Certifications . . . . . . . . . . . . . . V1-T3-3
3 Catalog Number Selection . . . . . . . . . . . . . . . . V1-T3-3
Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T3-4
3 ATS Ready Loadcenter . . . . . . . . . . . . . . . . V1-T3-5
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-6
3
3
3
3
3
3
3 Product Description Application Description
3 50, 100, 150, 200 and 400 A Green Line of Automatic 50, 100, 150, 200 and 400 A
Fully Automatic Transfer Switches Switches
3 All Eaton automatic transfer With the rising cost of 100, 200 and 400 A switches
switches (ATS) monitor utility commodities and fuel are capable of “whole house”
3 and generator voltages and
will automatically connect to
in today’s economy,
consumers are concerned
power transfer in residential/
small business applications.
3 the appropriate source of
power. Eaton offers two
with maximizing the value
of their purchases.
types of automatic transfer 50 A—Indoor Installation—Selected Load Pre-Wired
3 switches to suit your personal Electrical loads are now
Meter 50 A
backup power needs—the intelligently managed with
Indoor Transfer
3 standard ATS EGSX series Eaton’s Green Line of
automatic transfer switches.
Standby
Generator
Switch
with load shedding 100/200 A
The active load management
3 capabilities and the Green
ATS EGSU series that inside each Green ATS allows
Service Panel
3 As a part of Eaton’s
commitment to quality,
Air Conditioner
3
Attenuated Disconnect
Enclosure
3 Fuel Supply
(NG or LP)
3 100/200 A
Air Conditioner Service Panel
3
V1-T3-2 Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com
Residential Backup Transfer Switch Solutions
Automatic Transfer Switches
3.1
Standards and
Certifications 3
●
●
UL 1008 listed
UL 67 listed
3
● CSA 3
3
3
3
Catalog Number Selection
3
Standard Automatic Transfer Switches—EGSX Series
3
EGSX 200 NSEA
3
Service Entrance Rated
Type Ampere
Rating
Loadcenter
(CH Type, Integral)
NSEA = Service entrance 3
EGSX = Eaton EGSX transfer (normal source only)
switch series 50 = 50 A
100 = 100 A
Blank = None
L12 = 12 circuits N1
A = Non-service entrance
3
150 = 150 A L12R = 12 circuits N3R
200 = 200 A
400 = 400 A
L24R = 24 circuits N3R 3
3
Green Automatic Transfer Switches—EGSU Series
3
EGSU 200 NSE ACA
3
Type Ampere
Load Management
ACA = Active load management
3
Service Entrance Rated
Rating
EGSU = Eaton EGSU “Green” universal
transfer switch series 100 = 100 A
Loadcenter
(CH Type, Integral)
NSE = Service entrance
(normal source only)
3
150 = 150 A Blank = None Blank = Non-service entrance
200 = 200 A
400 = 400 A
L24 = 24 circuits 3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com V1-T3-3
3.1 Residential Backup Transfer Switch Solutions
Automatic Transfer Switches
Product Selection
3
3 EGSX50L12R Standard Automatic Transfer Switches 1
No. of
3
Service Load Contactor No. of Withstand No. of Most Common
Ampere Entrance Shed Wire Size Cables Current (rms) Circuits Frequency Enclosure Generator Catalog
Rating Voltage Rated Contacts Range(s) per Phase at 240 Vac Included 2 (Hz) Type Sizes (kW) 2 Number
3 50 120/240 No 2 #14–#6 1 5000 12 50/60 NEMA 1 9, 11 EGSX50L12
(indoor)
3 50 120/240 No 2 #14–#6 1 5000 12 50/60 NEMA 3R 9, 11 EGSX50L12R
(outdoor)
3
200 120/240 Yes 2 #4–300 kcmil 1 10,000 — 50/60 NEMA 3R 16, 20, 22 EGSX200NSEA
(outdoor)
400 120/240 Yes 2 750 kcmil–2 1/2 35,000 — 50/60 NEMA 3R >22 EGSX400NSEA
3 300 kcmil–1/0 (outdoor)
3
EGSU200NSEACA Green Automatic Transfer Switches 4—Featuring Active Load Management Technology
3 Service Contactor No. of Withstand No. of Most Common
Ampere Entrance Wire Size Cables Current (rms) Circuits Frequency Enclosure Generator Catalog
3 Rating Voltage Rated Range(s) per Phase at 240 Vac Included 2 (Hz) Type Sizes (kW) 3 Number 5
100 120/240 No #14–#2/0 1 10,000 — 50/60 NEMA 3R 9, 11, 16 EGSU100ACA
3 (outdoor)
100 120/240 Yes #14–#2/0 1 10,000 — 50/60 NEMA 3R 9, 11, 16 EGSU100NSEACA
3 100 120/240 No #14–#2/0 1 10,000 24 50/60
(outdoor)
NEMA 3R 9, 11, 16 EGSU100L24RACA
3
(outdoor)
200 120/240 No #4–300 kcmil 1 10,000 — 50/60 NEMA 3R 16, 20, 22 EGSU200ACA
(outdoor)
3 200 120/240 Yes #4–300 kcmil 1 10,000 — 50/60 NEMA 3R 16, 20, 22 EGSU200NSEACA
(outdoor)
3 400 120/240 Yes 750 kcmil–2 1/2 35,000 — 50/60 NEMA 3R >22 EGSU400NSEACA
300 kcmil–1/0 (outdoor)
3 Notes
3
1 Standard ATS “EGSX” Series compatible with Generac generators only.
2 Uses CH type circuit breakers.
3 For reference only. Generator size must be determined with proper/actual load calculations.
3
3
3
3
3
3
V1-T3-4 Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com
Residential Backup Transfer Switch Solutions
Automatic Transfer Switches
3.1
ATS Ready Loadcenter
From the far-reaching power The ATS Ready loadcenter ATS Ready Loadcenter Features
3
failures brought on by gives homebuilders and CH Premium Type 200 A For use with 9 or 11 kW
3
● ●
hurricanes and snow/ice electrical contractors the single-phase MCB air-cooled generators
storms, to the increasing flexibility to install a generator 36-circuit loadcenter CH cover included
3
●
power outage concerns and ready system or to install a ● 50 A ATS “EGSX” type kit
an aging electrical loadcenter and easily add an
● Lifetime warranty on CH
for factory or field
3
infrastructure, backup power ATS in the future. Backup loadcenter and breakers
installation (compatible ● NEMA 1 design
is more important than ever. power had never been that with Eaton generators only)
Eaton’s ATS Ready loadcenter versatile before. UL Listed
3
●
Dimensions
3 Approximate Dimensions in Inches (mm)
3 Automatic Transfer Switches
3 Catalog Number Width Height Depth
Weight
Lbs (kg)
3 EGSX200A
EGSX150NSEA
14.46 (367.3)
14.46 (367.3)
25.08 (637.0)
29.20 (741.7)
5.25 (133.4)
5.32 (135.1)
35 (15.87)
45 (20.41)
3
EGSU100NSEACA 14.46 (367.3) 16.87 (428.5) 5.32 (135.1) 28 (12.70)
EGSU150NSEACA 14.46 (367.3) 29.20 (741.7) 5.32 (135.1) 45 (20.41)
3
3
3
3
Product Description Application Description Features, Benefits and Functions 3
A manual transfer switch is a
device that is mounted next
Manual transfer switches
are most often used in
Eaton offers two manual
transfer switch backup power
3
to the loadcenter (distribution residential, agricultural solutions:
panel) in the home or small and light commercial 3
business. The manual applications. Comfort and
● Manual transfer switches
transfer switch is used in safety are key concerns ● Generator panels 3
conjunction with a portable of many homeowners
Manual Transfer Switches
backup power generator and
serves the purpose of turning
who are dependent on
an uninterrupted supply ● Panel and components 3
sold separately
selected circuits on and off
during a power outage. The
of electricity.
● Hardwired generator 3
transfer switch panel allows The increase in our connection
the owner to start up a dependence on power is
due in part to the popularity
● Ideal for new construction/ Manual Transfer Switch
3
generator to restore power to larger loads Indoor Design
critical circuits when utility of home offices and in-home
health care. Various heavily ● Sturdy copper bus 3
power is not available. construction
populated regions of the
The owner designates which United States experience ● Uses CH and CHT circuit 3
circuits are critical, such as periodic power outages breaker types (sold
the refrigerator and certain due to extreme weather separately) 3
lights. Sometimes called conditions, such as ice and ● Mechanically interlocked
emergency power panels or
emergency generator panels,
snowstorms, heat waves,
tornadoes or hurricanes.
main disconnects to 3
prevent paralleling of
manual transfer switch
panels provide the
These regions that include
the Pacific Northwest,
normal and emergency
power source
3
homeowner or small Atlantic Coast and the Gulf
business owner with a safe Coast are the strongest
● Indoor and outdoor
designs available
3
and easy way to continue markets for portable Manual Transfer Switch
using electrical appliances generators and manual Indoor/Outdoor Design 3
when the utility power transfer switches.
is unavailable temporarily.
3
3
3
3
3
3
Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com V1-T3-7
3.2 Residential Backup Transfer Switch Solutions
Manual Transfer Switches
3 7500
7500
10
10
30
30
CH10EGEN3060R
CH10EGEN3060SUR
R30211-20
—
10-7500 + RTE1075
—
—
—
—
—
3 7500 10 30 CH10EGEN3060RSU — — — —
7500 10 30 CH10GEN5030SN — — — —
3 7500 10 30 CH10GEN5030RSN — — — —
Generator Panel
12,000 10 50 CH10GEN5050SN — — — —
3 Indoor Design
12,000 10 50 CH10GEN5050RSN — — — —
3 Notes
1 Gen/Trans device is not supplied with a power cord.
3
2 Generac device is 7200 maximum watts on six-circuit device and 12,000 maximum watts on 10-circuit device.
3
3
3
3 Generator Panel
Outdoor Design
3
3
3
3
3
3
3
3
3
V1-T3-8 Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com
Residential Backup Transfer Switch Solutions
Manual Transfer Switches
3.2
Product Selection
3
Manual Transfer Switches and Generator Panels Selection
Main/
3
3
Enclosure Number Ampere Emergency Feeder Included Catalog
Type Watts of Circuits Rating Ampere Rating Breakers Accessories Number
3
Standard Manual Transfer Switch
NEMA 3R 5000 4–8 30 Provision Provision None CH48GEN3060R
NEMA 1 10,000 8–16 60 Provision Provision None CH816GEN6060
3
Generator Panel
NEMA 1 5000 6 20 60/20 5–1P151–1P20 None CH6EGEN2060 3
NEMA 3R 5000 6 20 60/20 5–1P151–1P20 None CH6EGEN2060R
NEMA 1 5000 6 20 60/20 5–1P151–1P20 Two-pole surge protector CH6EGEN2060SUR 3
3
NEMA 3R 5000 6 20 60/20 5–1P151–1P20 Two-pole surge protector CH6EGEN2060RSU
NEMA 1 7500 10 30 60/30 6–1P152–1P2012P30 None CH10EGEN3060
NEMA 3R 7500 10 30 60/30 6–1P152–1P2012P30 None CH10EGEN3060R
3
NEMA 1 7500 10 30 60/30 7–1P152–1P2012P30 Two-pole surge protector CH10EGEN3060SUR
NEMA 3R 7500 10 30 60/30 7–1P152–1P2012P30 Two-pole surge protector CH10EGEN3060RSU 3
Switched Neutral Manual Transfer Switch
NEMA 1 7500 10 30 50/30 6–1P15, 2–1P20, 1–2P30 None CH10GEN5030SN 3
NEMA 3R
NEMA 1
7500
12,000
10
10
30
50
50/30
50/50
6–1P15, 2–1P20, 1–2P30
6–1P15, 2–1P20, 1–2P30
None
None
CH10GEN5030RSN
CH10GEN5050SN
3
NEMA 3R 12,000 10 50 50/50 6–1P15, 2–1P20, 1–2P30 None CH10GEN5050RSN 3
3
Power Inlet Boxes
Ampere Catalog 3
Description Rating Voltage Number
Flush flange kit (for use with — 120/240 V CHEGENFKIT 3
generator panel only)
Power inlet box 20 120/240 V EGSPIB20 3
Power inlet box 30 120/240 V EGSPIB30
Power inlet box 50 120/240 V EGSPIB50 3
3
Warranty
Manual Transfer Switch
3
● 15-year loadcenter
warranty 3
Lifetime branch breaker
3
●
warranty
Generator Panel
● 15-year loadcenter
3
●
warranty
Lifetime branch breaker
3
warranty
3
3
3
3
3
3
Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com V1-T3-9
3.2 Residential Backup Transfer Switch Solutions
Manual Transfer Switches
3 Installation Diagrams
3 Manual Transfer Switches—Indoor Installation Diagram Generator Panels—Indoor Installation Diagram
3 Eaton
Manual Transfer Switch Utility
Generator Panel Utility
Power
Power Feed
3 Power
Feed
Power
Inlet
Box* Existing
Inlet
3 Box*
Existing
Main
Main
Power
Power Power Power Panel
3 Cord* Panel
(Loadcenter)
Cord* (Loadcenter)
3 Two-Pole, 60 A Breaker*
to Feed the Emergency
Two-Pole, 60 A Breaker*
to Feed the Emergency
Power Panel From Your Generator Panel From
3 Hardwired
Existing Main Power Panel
(Loadcenter)
Your Existing Main
Power Panel (Loadcenter)
3 Generator* Electrical
Connection*
* Not Included Generator* Electrical Wiring
or Power Cord*
Prewired Connector
for Faster Installation
- Included * Not Included
3
3 Manual Transfer Switches—Outdoor Installation Diagram Generator Panels—Outdoor Installation Diagram
3 Eaton
Manual Transfer Switch Utility
Two-Pole, 60 A
Breaker* to Feed
Generator Panel
the Emergency
3
Power Feed Generator Panel
Power Existing From Your
Inlet Main Existing Main
3 Box* Power
Panel
Power Panel Prewired
Power Connector
(Loadcenter)
3 Cord* for Faster
Installation -
Two-Pole, 60 A Breaker* Included
3 to Feed the Emergency
Power Panel From Your
Utility
Power
Existing Main Power Panel Feed
3 (Loadcenter)
3
Generator* Hardwired Electrical Connection* * Not Included Power Cord*
Generator*
*Not Included
3
3 Dimensions
3 Approximate Dimensions in Inches (mm)
3
3
V1-T3-10 Volume 1—Residential and Light Commercial CA08100002E—February 2018 www.eaton.com