GasCalc® includes the following calculation modules

Module Application examples


(properties to be calculated)
1. Gas properties to ISO 6976 • Energy billing, conversion of reference
Superior calorific value, Wobbe index, states (superior calorific value, normal
normal density, molar mass, etc. density)
• Monitoring / compliance with DVGW Code
of Practice G260 (Wobbe index), for
example biogas injection
2. Combustion • Design / control of combustion processes
Air requirement, exhaust gas analysis,
etc.
3. CO 2 emission factor • Determination of CO 2 output in accordance
Calculated from gas analysis or based with DVGW Code of Practice G693 for
on billing data emissions trading
4. Methane number • Avoiding engine knock in gas engines /
Methane number to AVL method and packaged CHP
simplified method • Monitoring / compliance with natural gas
quality required at CNG fuelling stations
5. SGERG • Energy billing - conversion of volume at
Thermal properties flowing conditions to volume at normal
conditions (DVGW Code of Practice G486)
(Compression factor, gas law deviation
factor, density) to ISO 12213-3
6. AGA 8 • Energy billing in accordance with module 5
Thermal properties to ISO 12213-2, based on full analysis (DVGW Code of
caloric properties (specific heat Practice G486, 2nd supplement)
capacity, enthalpy, entropy, etc.) to • Design of heat exchangers, expansion /
ISO 20765-1 compression processes
7. GERG 2004 reference equation • Calculation of data for liquefied natural gas
Thermal and caloric properties over (LNG) processes
entire fluid range (gas phase, liquid • Calculation of dew points, boiling points
phase, two-phase boundary) • Calculation of data for extreme temperature
and pressure conditions (storage)
• Calculation of pure substance data

8. GERG Water • Monitoring / compliance with DVGW Code


Water dew point to ISO 18453 of Practice G260
9. Transport properties • Calculation of pressure loss in pipelines
Dynamic viscosity, kinematic viscosity, • Fluid flow calculations (Reynolds number)
heat conductivity, etc.
10. Compression • Design / optimisation of natural gas
Isentropic / polytropic changes of state compressors
based on AGA 8 equation • Compressor efficiency

11. Heater • Design and operation of heaters in pressure


Required temperature increase, heat reducing stations (regulators)
output and gas consumption of natural
gas-driven heaters to ISO 20765-1
12. Orifice calculation • Determination of normal volume for
to ISO 5167 differential pressure meters

E.ON SE | Betrieb Essen – Brüsseler-Platz 1 – 45131 Essen