AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
2/130
Summary
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
2.2.2.5 Provide, cut, bend and fix in position reinforced steel Kg 632.20
bar. All according to structural drawing. Price should
also include tying wires.
2.3.1.5
Cart away of surplus excavated materials m3 43.50
Supply and compact approved backfill
2.3.1.6
selected material m3 16.00
2.3.2 Stone masonary work
2.3.2.1 provide, place and build with broken stone
for 250mm hardcore with hard basaltic
stone or similar stone m2 11.80
2.3.2.2 Provide basaltic or equivalent masonry wall
below ground surface. m3 12.36
2.3.2.3 Ditto,but above ground level m3 0.95
2.3.3 Provide, cut, bend and fix in position
reinforced steel bar. All according to
structural drawing. Price shall include
tying wires
15/130
#2.3. Guard House WF
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
16/130
#2.3. Guard House WF
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
17/130
#2.3. Guard House WF
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
18/130
#2.3. Guard House WF
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
19/130
#2.3. Guard House WF
AAWSA:PROJECT OFFICE SOUTH AND OUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
BILL 2.4: CONSTRUCTION OF TOILET ROOM, SEPTIC TANK, SOAK AWAY PIT.
m 2.00
2.4.5.7 Supply & fix diameter 100mm down pipe in G-
28 including 1mm thick metal support brackets
fixed at a maximum interval of 1000 mm fixed
to walls or columns m 8.00
2.4.5.8 Supply and fix 25x 250 mm fascia board to ,, 2.00
purlin
2.4.5.9 Supply and fix metal windows size
(0.50x0.50)m price includes 4mm thick clear
glass No. 2.00
2.4.5.10 Supply and fix metal doors size (1.9x0.80)m
with figured glass in upper half portion ,, 1.00
Finishing; finishing work shall include all
surface pre-cleaning, polishing and cleaning
at the end of finishing
2.4.6 Floor screed in cement mortar 20 mm thick m2 2.25
2.4.6.1 Apply three coats of plaster in cement mortar to
internal cement concrete block wall m2 17.98
2.4.6.2 Ditto, but to external face of wall m2 25.03
2.4.6.3 Apply 3 coats of plastic paint to internal walls
and synthetic paint to metal doors and windows
m2 16.99
2.4.6.4 Ditto, but to external face of wall m2 24.49
2.4.6.5 Supply and fix Turkish type WC with high flush
cystern complete with cold water connection
and waste pipe line DN 110mm up to septic
tank. LS 1.00
2.4.7 Miscellaneous
2.4.7.1 Stone pitched trapezoidal drainage ditch
pointed with mortar (1:3) (top width=40 cm,
bottom width=20 cm and depth=30cm) around
the control panel room as per the drawing
m 12.00
2.4.7.2 Stone pavement around the building 1m wide m 11.60
2.4.7.3 Light points complete wiring and the necessary
accessories LS. 1.00
Total for Toilet Room
Unit Price
Item No. Description Unit Qty. (birr)
Unit Price
Item No. Description Unit Qty. (birr)
2.4.9 Construction of Soak Away Pit
2.4.9.1Site clearing to depth of 20cm m2 8.00
2.4.9.2Excavation of soil to depth of 3mts. In ordinary
soil m3 23.00
2.4.9.3 Excavate for foundation,in soft rock m3 12.00
2.4.9.4 Ditto, but in hard formation not exceeding 3mts. m3 6.00
2.4.9.5 Cart away of surplus excavated materials to a
distance of 1- 2kms m3 29.00
2.4.9.6
Basaltic or equivalent dry stone masonry wall. m3 14.00
2.4.9.7 Supply and fill course gravel m3 4.80
2.4.9.8 Ditto, but fine gravel m3 2.40
2.4.9.9 Ditto, but sand m3 2.40
2.4.9.10 Reinforced concrete cover slab (C-25) in 10 cm
thick including reinforcement bar as per the
drawing m3 0.70
Total for Soak Away Pit
TOTAL
USD
Amount (birr)
Amount (birr)
d DN 300 No 4
e DN 250 No 2
f DN 200 No 1
2.5.4.3 Flanged Anchoring Spigot piece PN16
a DN 500 No 8
b DN 400 No 9
c DN 350 No 6
d DN 300 No 6
d DN 250 No 2
e DN 200 No 1
2.5.4.4 Double flanged Butterfly Valve PN16
a DN 500 No 3
b DN 400 No 5
c DN 350 No 3
d DN 300 No 1
e DN 250 2
2.5.4.5 Double Flanged Reducer PN16
a DN '500/400 No 1
b DN '500/350 No 1
c DN '400/350 No 1
d DN '400/300 No 3
e DN '400/250 No 3
f DN '400/200 No 1
g DN '350/300 No 2
h DN '300/250 No 2
2.5.4.6 Double Flanged Gate Valve PN16
a DN 300 No 7
b DN 250 No 10
c DN 200 No 1
2.5.4.7 Flanged Socket pipe PN16
a DN 500 No 3
b DN 400 No 4
c DN 350 No 3
d DN 300 No 10
e DN 250 No 10
f DN 200 No 1
2.5.4.7 Double Socket Bend PN16
90O Bend
a DN 400 No 2.00
b DN 300 No 6.00
c DN 250 No 5.00
45O Bend
a DN 500 No 3.00
b DN 300 No 8.00
c DN 250 No 2.00
22.5O Bends
a DN 500 No 8.00
b DN 400 No 3.00
c DN 300 No 39.00
d DN 250 No 11.00
11.25O Bends
a DN 400 No 44.00
b DN 300 No 260.00
c DN 250 No 29.00
2.5.4.8 All Flanged Tee ( 90º Tee) PN16
DN 150 No 2.00
2.4.4.9 Wash Out Valve (WOV) with accesseries
a All Flanged Tee 90 degree
DN 200/200 No 2.00
DN 250/200 No 6.00
DN 300/200 No 13.00
DN 400/200 No 3.00
b Double Flanged Gate Valve
DN 200 No 24.00
c Flanged Spigot
DN 200 No 24.00
d Socket Spigot
DN 200 No 24.00
e Socket Flanged
DN 200 No 24.00
g Flap Valve (WOV)
DN 200 No 24.00
2.4.4.10 Air Releas Valve (ARV) with accesseries
a All Flanged Tee 90 degree
DN 250/200 No 7.00
DN 300/200 No 10.00
DN 400/200 No 5.00
DN 500/200 No 3.00
b Gate Valve
DN 200 No 25.00
c Flanged Spigot
DN 200 No 50.00
d Dismantling Joint
DN 200 No 50.00
e Air Releas Valve (ARV)
DN 200 No 25.00
Construction of valve chamber with Cast iron
manhole on which the name "AAWSA" is
2.5.5 printed cover; price includes manhole covers,
concrete, reinforcement, formwork, etc.
2.5.9.1
Total of Bill No 2.5.: Construction of Collector
Pipe Line
S
TOTAL
USD
DN500mm No 2.00
DN400mm No 2.00
DN300 No 2.00
3.1.4.1.9 Double Flanged Bend
90O Bend
DN500mm No 2.00
DN400mm No 2.00
DN300mm No 2.00
90O Bend (Docked leg)
DN500mm No 2.00
DN400mm No 2.00
DN300mm No 2.00
3.1.4.1.10 Double Flanged Gate Valve
DN800mm No 3.00
DN200mm No 1.00
3.1.4.1.11 All Flanged Tee
DN300/200mm No 2.00
DN800/800 No 2.00
3.1.4.1.12 Float Valve
DN500mm No 1.00
DN400mm No 1.00
3.1.4.1.13 Suction Strainer
DN800mm No 2.00
3.1.4.1.14 Pipe support with pipe clamp, wall bracket,
LS 1.00
foot plate and anchor bolts
3.1.4.1.15 Supply and install water level
LS 1.00
indicator(marker)
a DN 500mm No 2.00
b DN 300mm No 2.00
3.2.9.3 Flanged spigot , L = 1.m
a DN 800mm No 2.00
b DN 500mm No 3.00
c DN 300mm No 2.00
d Socket spigot pipe , L = 6m
e DN 800mm No 2.00
f DN 500mm No 2.00
3.2.9.4 Spigot Short Pipe L= 0.50m
DN500mm No 2.00
3.2.9.5 Double Socket 45O Bend
DN 500mm No 2.00
3.2.9.6 Double flanged Pipe, L= 6m
a DN 500mm No 2.00
b DN 300mm No 2.00
DN500mm No 2.00
3.2.9.12 Double Flanged Gate Valve
a DN 800mm No 2.00
b DN 200mm No 2.00
3.2.9.13 Double Flanged Puddled Pipe , L=
1.50m
a DN 500mm No 3.00
b DN 300mm No 2.00
c DN 200mm No 2.00
3.2.9.14 All Flanged Tee
DN 300/200mm No 2.00
3.2.9.15 Suction Strainer
DN 800mm No 2.00
3.2.10 Miscellaneous
3.3.10.2 15 mm m 12.00
3.3.10.3 20 mm m 36.00
3.3.10.4 uPVC pipe for sewage drainage
3.3.10.5 Dia. 150 mm ml 30.00
3.3.10.6 Dia. 100 mm ml 6.00
3.3.10.7 Dia. 50 mm ml 12.00
3.3.10.19 50 mm m 6.40
3.3.10.20 80 mm m 6.40
3.3.10.21 100 mm m 5.90
3.3.10.23 Supply & install vent caps made of rigid 80
mm PVC to be connected to the roof terminal No. 1.00
of vent pipe
3.3.10.24 Supply & fix sanitor sink made of concrete 40
mm thick Size: 1000 x 500 x 400 mm No. 1.00
3.4.1.3
Excavate for foundation,in softrock formation m3 2.00
3.4.1.4 Excavate for foundation,in hard rock formation m3 2.50
3.4.1.5 Cart away of surplus excavated materials m3 43.50
Supply and compact approved backfill
3.4.1.6
selected material m3 16.00
3.4.2 Stone masonary work
3.4.2.1 provide, place and build with broken stone for
250mm hardcore with hard basaltic stone or
similar stone m2 11.80
3.4.2.2 Provide basaltic or equivalent masonry wall
below ground surface. m3 12.36
3.4.2.3 Ditto,but above ground level m3 0.92
3.4.3 Provide, cut, bend and fix in position
reinforced steel bar. All according to
structural drawing. Price shall include
tying wires
3.4.5.2
Ditto, but for parapet wall (150x200x400)mm m2 11.50
Supply, assemble and fix in position
eucalyptus roof truss of length 3.6 m price
3.4.5.3 shall include the application of three coats and
external anti-termite treatment as per the
drawing
No. 6.00
Supply and fix purlin in zigba wood size 50 x
70 mm nailed into eucalyptus truss including
3.4.5.4 three coats of anti - termite external treatment
m 21.00
85/130
#3.5 Chilorination Room TG
SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
AAWSA:PROJECT OFFICE
86/130
#3.5 Chilorination Room TG
SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
AAWSA:PROJECT OFFICE
87/130
#3.5 Chilorination Room TG
SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
AAWSA:PROJECT OFFICE
3.5.9 Miscellaneous
88/130
#3.5 Chilorination Room TG
SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
AAWSA:PROJECT OFFICE
89/130
#3.5 Chilorination Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
BILL 3.6: CONSTRUCTION OF SEPTIC TANK, SOAK AWAY PIT @TULLU GUDDO
ITEM UNIT PRICE TOTAL
ITEM DESCRIPTIONS UNIT QUANTITY
NO. BIRR USD BIRR USD
CONSTRUCTION OF TOILET ROOM, SEPTIC
3.6 TANK, SOAK AWAY PIT
3.6. Construction of Toilet Room
3.6.1 Earth work
3.6.1.1 Excavate 20 cm topsoil,clearing and grubbing m2 15.20
3.6.1.2 Excavate for foundation,in common soil depth not
exceeding 2.0m. m3 5.60
3.6.1.3 Excavate for foundation,in soft rock m3 0.50
3.6.1.4 Excavate for foundation,in hard rock m3 1.50
3.6.1.5 Cart away of surplus excavated materials m3 13.50
3.6.1.6 Supply and compact approved backfill selected
material m3 2.50
3.6.2 Stone masonary work
3.6.2.1 provide ,place and build with broken stone for
250mm hardcore with hard basaltic stone or
similar stone m3 2.25
3.6.2.2 Provide basaltic or equivalent masonry wall below
and above ground surface m3 5.60
3.6.2.3 Ditto,but above ground level m3 0.90
3.6.3 Provide, cut, bend and fix in position
reinforced steel bar. All according to structural
drawing. Price shall include tying wires
3.6.9.4
Ditto, but in hard formation not exceeding 3mts. m3 6.00
3.6.9.5 Cart away of surplus excavated materials to a
distance of 1- 2kms m3 29.00
3.6.9.6 Basaltic or equivalent dry stone masonry wall. m3 14.00
3.6.9.7 Supply and fill course gravel m3 4.80
3.6.9.8 Ditto, but fine gravel m3 2.40
3.6.9.9 Ditto, but sand m3 2.40
3.6.9.10 Reinforced concrete cover slab (C-25) in 10 cm
thick including reinforcement bar as per the
drawing m3 0.70
Total for Soak Away Pit
Total of Bill No.3.6. TOILET ROOM, SEPTIC
TANK, SOAK AWAY PIT
ml
3.7.4 Metal Work
provide & install RHS grilled & framed Metal works all according
3.7.4.1 to the tender drawing. Price includes one coat of primer & two
coates of oil paint.
3.7.4.2 Main Gate
3.7.4.3 Size:- (500 x 230)cm No 1.00
3.7.4.4 Pedestrian Gate
3.7.4.5 Size:- (100 x 230)cm No 2.00
3.7.4.6
5cm thick class C-20 Concrete copping on main gate columns No 4.00
15x15cm reinforced concrete post as per the detail drawing.
3.7.4.7 Price includes form work, reinforcement bar and 50cm deep dia
50cm concrete pad foundation. No 12.00
3.7.4.8 50x50cm dressed stone m3 6.20
AMOUNT
USD
AMOUNT
AMOUNT
AMOUNT
AMOUNT
105/130
#3.8. SCADA Control Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
106/130
#3.8. SCADA Control Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
107/130
#3.8. SCADA Control Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
108/130
#3.8. SCADA Control Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
109/130
#3.8. SCADA Control Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
110/130
#3.8. SCADA Control Room TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
E @ TULLU GUDDO
TOTAL
USD
3.10.2.2
Supply and construct stone masonary with hard
m3 39.20
trachytic stone 50 cm thick below ground level.
121/130
#3.10 Transformer House TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
122/130
#3.10 Transformer House TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
3.10.5.3
plastering of internal wall and exposed face of
external beam & column in cement mortar 1:3 m2 210.00
maximum thickness of 25mm in three coats.
123/130
#3.10 Transformer House TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
3.10.8.1
Suspended type fluorescent luminaries, type
philips TMS 012/1.36 or equivalent with 1x36W No. 6.00
lamps suspended by 2.5 mm steel rope.
124/130
#3.10 Transformer House TG
AAWSA:PROJECT OFFICE SOUTH AND SOUTH EAST ADDIS ABABA AREA WSP FROM SANF WELL FIELD
11.1.3 Shape Road Bed and Compact to 90% AASHTO Modified m2 312,000
Provide, cut, bend and fix in position reinforced steel bar. All
11.2.3.4 according to structural drawing. Price should also include ton 3.50
tying wires.