Sei sulla pagina 1di 40

the Energy CominG

the Energy CominG


In 1970 Juan
Bornay starts
his project:
Produce
energy with
the wind
the Energy CominG

48 years producing
Small Wind Turbines
the Energy CominG 100 % produced by Bornay in Europe

Raw materials Mechanics Electrics Composites

Assembly Quality Delivery R+D


the Energy CominG Our History

1970 1978 1982


FIRST FIBERGLASS INDUCTION
BORNAY PARTS ALTERNATOR

2017
1988 1993
1984
PERMANENT FIBERGLASS/CARBON
INJECTED
MAGNET ALTERNATORS FIBER BLADES.
NYLON BLADES
ADJUSTABLE BLADE PITCH TILTING BRAKE

2000
1997 2008
FIBERGLASS/CARBON
NEODYMIUM GRID CONNECTION
FIBER BLADES
MAGNETS SYSTEMS
BY RTM
the Energy CominG

A step ahead on
small wind turbines
the Energy CominG Bornay Wind Turbines

600 1500 3000 6000


the Energy CominG

Bornay 600 Battery charge 12 v.


24 v.
48 v.
Grid connection 120 v.
220 v.

Bornay 1500 Battery charge 24 v.


48 v.
Grid connection 120 v.
220 v.

Bornay 3000 Battery charge 24 v.


48 v.
Grid connection 120 v.
220 v.

Bornay 6000 Battery charge 48 v.


Grid connection 120 v.
220 v.

16 models
7 controls
2 applications
the Energy CominG Aerogeneradores Wind +

Wind 13 + Wind 25.2 + Wind 25.3 +

Regulador MPPT Interface Interface Telecom


the Energy CominG
Wind 13 + 12 v.
MPPT Battery charge 24 v.
48 v.
Wind 25.2 +
Grid connection
Interface Wind + Water pumping
Wind 25.3 + Telecom

3 models
2 controls
Multiple applications
the Energy CominG Developments / Improvements

Unique alternator 220 vac Better costs


Better wind performance
Better cut-in windspeed
Maximum efficiency
EU efficiency up to 96 %
Better wind turbine control
(Amps / voltage / rpm)

Wind 13 + @ 1,5 kW - 12 m/s

Wind 25.2 + @ 3 kW - 12 m/s

Wind 25.3 + @ 5 kW - 12 m/s


the Energy CominG Developments / Improvements

MPPT charge controller

· Unique model
· 220 Vac input from wind turbine
· 12, 24 or 48 Vdc output
· Limited output power depending of the battery voltage
· Applicable batteries: Flooded, AGM, GEL, LiOn
· Functional without batteries
· MPPT tracking with self-learning algorithm.
· “Quiet” mode
· Touch color display: information / program
· Wind turbine control by amperaje, voltage and rpm
· Windspeed anemometer input (optional)
· Auxiliar relay (2)
the Energy CominG Developments / Improvements

Interface Wind +

· Allow us to connect the wind turbine directly to the telecom rack


· Keep the wind turbine under control at any condition
· Direct DC or AC for all kind of uses:
- DC Water pumping
- AC Water pumping
- Grid connection
- Motors
- Telecom
· Wind turbine functionalities optimization.
· MODBUS communication to interact with external equipments.
· Wind turbine control by amperaje, voltage and rpm
· Windspeed anemometer input (optional)
· Auxiliar relay (2)
the Energy CominG Developments / Improvements

Placement
· Previous to the installation of the wind turbine
· Windspeed data logger
· Site parametrization
· Selection of the ideal wind turbine
· Posible wind turbine improvements

· blade diameter modifications


· power curve definition

Maximum Efficiency
· Power production at low windspeed up to 20% more than previous models

· Alternator efficiency up to 96 %
the Energy CominG Developments / Improvements

Security x 3
· Three control systems improve the security of Wind + wind turbines

· Electronic controller
· Wind + Speed Control
· Tilting disorientation

Modularity
· Options to integrate the wind turbine into many applications

· ModBus Communication
· AC / DC applications
· Direct uses
the Energy CominG Developments / Improvements

Monitoring
· Monitor your wind turbine thru Bvisual platform

· Monitor your Renewable Energy system


solar / wind production, battery, status, inverter status …
(Victron Energy Remote Monitoring)
the Energy CominG Developments / Improvements

Remote Control
· Control your wind turbine remotely

· Change power curve parameters


· Reduce power peak production
· Update firmware

· Protection mode in case of natural disasters


the Energy CominG Developments / Improvements

Wind + Speed Control


Intelligent speed control system over the power curve
Cp
Lambda
the Energy CominG

Why should we use


a Wind Turbine ??
the Energy CominG Why should we use a Wind Turbines ?

Typical photovoltaic productions


the Energy CominG Why should we use a Wind Turbines ?

Typical photovoltaic productions


the Energy CominG Why should we use a Wind Turbines ?

Typical photovoltaic productions


the Energy CominG Why should we use a Wind Turbines ?

Typical wind turbine productions


the Energy CominG Why should we use a Wind Turbines ?

Typical hybrid production (wind / sun)

More stable production


the Energy CominG Why should we use a Wind Turbines ?

Battery cycles in a typical PV system

Day / Night cycle


the Energy CominG Why should we use a Wind Turbines ?

Battery cycles in a typical PV system


the Energy CominG Why should we use a Wind Turbines ?

Battery cycles in an hybrid system

No wind
Wind
the Energy CominG Why should we use a Wind Turbines ?

Battery cycles in an hybrid system


the Energy CominG Why should we use a Wind Turbines ?

Equalization Charge

Battery voltage
Battery current

Bulk Absorption Float Equalization


the Energy CominG Why should we use a Wind Turbines ?

Equalization Charge

Battery manufacturer: 15,6 - 16,5 Vdc


Solar controller manufacturer: 15 Vdc
the Energy CominG

Applications
the Energy CominG Off Grid Systems
the Energy CominG Direct Water Pumping
the Energy CominG Grid connection
the Energy CominG Telecom
the Energy CominG Direct Telecom AC / DC System
lAtheEneRgía
EnergyquE
CominG
VieNe

8000 installations Worldwide


the Energy CominG

Our Team
the Energy CominG Institutional relations
the Energy CominG
Thanks,
for your attention

www.bornay.com

Potrebbero piacerti anche