Sei sulla pagina 1di 1

DESIGN OF ISOLATED FOOTING(RF1--14&20)

INPUT DATA :-
Compressive strength of concrete(fck):- 25 N/sqmm
Tensile strength of steel(fy):- 500 N/sqmm
Safe bearing capacity of soil(sbc):- 160 KN/sqm
Ultimate axial load(Pu):- 2437.5 KN Input Data
Moment about X-axis(Mx):- 0.52 KN-m
Moment about X-axis(My):- 2.69 KN-m
Breadth of column/Pedastal(b):- 0.23 m
Depth of column/Pedastal(d):- 0.6 m
DESIGN:-
Type of footing selected RECTANGULAR
Area of footing required 10.422 sqm
Length of footing 3.86 m
Breadth of footing 2.7 m
Depth of footing required 720 mm
Area of steel required in longitudinal direction 1676.166667 sqmm
Dia.of Bar proposed 16 mm
Spacing required 120 mm
Percentage of steel provided 0.263963255 >0.15.Hence O.K
Area of steel required in transverse direction 707.125 sqmm
Dia.of Bar proposed 12 mm
Spacing required 160 mm
CHECK FOR ONE-WAY SHEAR:-
Nominal Shear stress(Tv) 0.367102441 N/sqmm
Maximum Shear strength of section 3.1 N/sqmm >Tv.Hence the section is adequate
Design Shear force(Vuc) 237.1456352 KN
Nominal Shear force(Vu) 233.1100499 KN <Vuc.Hence no shear reinforcement required
CHECK FOR TWO-WAY SHEAR:-
Punching Shear force(Vp) 2191.404323 KN
Punching Shear strength of section 2944.8125 KN >Vp.Hence the section is safe
Percentage of steel provided in tranverse direction 0.127266592 >0.12.Hence O.K