Sei sulla pagina 1di 5

ColumnBase

Demo v4.0.0 Envelope Design Report License ID: DemoVersion4.0.0

Job No.
Company:
Current Time: 2017/08/22 15:35:37

Design Preferences
Steel Design Code: AISC360-10 [LRFD] FooƟng/Grout Design Provision AISC360-10 ,J8 [LRFD]
Consider Tension-Shear InteracƟon for Bolts? Yes FooƟng/Grout Design Criteria Normal Stress
Anchor Threads Excluded From Shear Plane? No Bearing Strength Capacity Based on Design Code
Plate Design Criteria Von-Mises Stress
Plate Strength ReducƟon Factor 0.9

Embedded Anchors Design Provision ACI318-14


Seismic Category C,D,E,F
Concrete Cracked Under Service Loads? Yes
Anchor reinf. and Supplementary reinf. is present? No

Demand/Capacity RaƟo Limit: 0.99

Envelope Design Summery

Check Point Controlling Load Combo Demand/Capacity RaƟo Check


Plate Stress Check LRFD03 0.45 Pass
FooƟng Bearing Stress Check LRFD02 1.03 Fail
Anchor Steel Failure In Tension and Shear LRFD03 0.37 Pass
Pullout Strength of Anchors LRFD03 0.79 Pass
Concrete Breakout in Tension LRFD03 1 Fail
Concrete Side-face Blowout Failure LRFD01 0 Pass

Plate Stress Check Demand/Capacity Ratio: 0.45 Check: Pass

General Data
Design Provisions AISC360-10 [LRFD]
Controlling Load Combo LRFD03 20.1
Design Criteria Von-Mises Stress 18.6
17.1
Design Formulation 15.6
14.1
(Demand/Capacity RaƟo) 12.6

σa (Allowable stress) 11.1


Fy = 50 ksi (Plate yield stress) 9.6
φ = 0.9 (Strength reducƟon factor) 8.1
σvm,max (Max. von-Mises stress under current load combo) 6.6
5.1
Plate Check 3.6
σvm,max [ksi] σa [ksi] DCR Check 2.1
0.6
20.222 45 0.45 Pass
Plate Bottom Face Von-Mises Stress [LRFD03]
Min Value: 0.49 , Max Value: 20.2217 ksi

ColumnBase Demo v4.0.0 Design Report (www.PCEESoft.com) Page 1 of 5


Footing Bearing Stress Check Demand/Capacity Ratio: 1.03 Check: Fail

General Data
Design Provisions AISC360-10 ,J8 [LRFD]
Controlling Load Combo LRFD02
0.071
FooƟng Bearing Capacity Based on Design Code
-0.229
FooƟng Design Criteria Normal Stress
-0.529
-0.829
Design Formulation
-1.129
-1.429
(Demand/Capacity RaƟo)
-1.729
f'c = 4 ksi (FooƟng Concrete f'c) -2.029
A1 = 196 in² <AISC360-10 J.8> -2.329
A2 = 558.001 in² <AISC360-10 J.8> -2.629
φc = 0.65 (Strenght reducƟon factor) -2.929
fp,max (Max. bearing stress under current load combo)
-3.229
-3.529
Footing Check
-3.829
fp,max [ksi] φc.fp [ksi] DCR Check
Footing Bearing Stress For LoadCombo: LRFD02
3.832 3.729 1.03 Fail Min Value: -3.8324 , Max Value: 0.0734 ksi

Anchor Steel Check In Tension and Shear Demand/Capacity Ratio: 0.37 Check: Pass

General Data
Design Provisions AISC360-10 [LRFD] J3.6-J3.7
Consider InteracƟon? Yes (Consider Tension-Shear InteracƟon?)
Threads Excluded? No (Threads are Excluded From Shear Plane?)
Load Combo Controlling LoadCombo
Anchors Fu 100 ksi (Minimum Tensile Strength of Anchor Bolts)
Anchors Fnt 75 ksi <Nominal Tensile Strength ,AISC360-10 Table J3.2>
Steel Failure Mode
Anchors Fnv 45 ksi <Nominal Shear Strength ,AISC360-10 Table J3.2>

Design Formulations
<AISC360-10 SecƟon J3.6 ,J3.7>
<AISC360-10 SecƟon J3.7>
(CalculaƟon of ulƟmate shear force and stress)
(Demand/Capacity RaƟo)
Ab (Nominal unthreaded body area of bolt)
F'nt (Nominal tensile stress modified to include the effects of shear stress)
Tu (Anchor bolt tension force under current load combo)
Vu (Anchor bolt shear force under current load combo)
frv (Shear stress under current load combo)
φ = 0.75 (Strength ReducƟon Factor)

Anchors Check
No. ID Ab [in²] CriƟcal LC T [kips] Vx [kips] Vy [kips] Vr [kips] F'nt [ksi] ϕRnt [kips] ϕRnv [kips] DCR Check
1 20 0.49 LRFD03 0 1.441 5.704 5.883 70.651 25.802 16.434 0.36 Pass
2 20 0.49 LRFD03 0 -1.441 5.704 5.883 70.651 25.802 16.434 0.36 Pass
3 20 0.49 LRFD03 9.675 0.621 5.536 5.571 72.077 26.323 16.434 0.37 Pass
4 20 0.49 LRFD03 9.675 -0.621 5.536 5.571 72.077 26.323 16.434 0.37 Pass

ColumnBase Demo v4.0.0 Design Report (www.PCEESoft.com) Page 2 of 5


Pullout Strength of Cast-in Anchors Demand/Capacity Ratio: 0.79 Check: Pass

General Data
Design Provisions ACI318-14 SecƟon 17.4.3
Load Combo Controlling Load Combo
Strength ReducƟon Factor(Seismic) 0.75
Anchors Type Headed Bolts
Anchors Head Type Hex
Concrete Cracked? Yes
FooƟng Concrete f'c 4 ksi
Pullout Failure Mode

Design Formulation
<ACI318-14 SecƟon 17.4.3>
ψc,p = 1 <ACI318-14 SecƟon 17.4.3.6>
φ = 0.7 <ACI318-14 SecƟon 17.3.3>
Abrg (Net bearing area of the head of anchor)
Nua (Anchor tension force under current load combo)

Anchors Check
No. ID CriƟcal LC da [in] Abrg [in²] 0.75ϕNpn [kips] Nua [kips] DCR Check
1 20 LRFD01 0.7874 0.725 12.179 0 0 Pass
2 20 LRFD01 0.7874 0.725 12.179 0 0 Pass
3 20 LRFD03 0.7874 0.725 12.179 9.675 0.79 Pass
4 20 LRFD03 0.7874 0.725 12.179 9.675 0.79 Pass

ColumnBase Demo v4.0.0 Design Report (www.PCEESoft.com) Page 3 of 5


Concrete Breakout Strength In Tension Demand/Capacity Ratio: 1 Check: Fail

General Data
Design Provisions ACI318-14 SecƟon 17.4.2
Controlling Load Combo Controlling LoadCombo
Anchors Type Headed Bolts
Strength ReducƟon Factor(Seismic) 0.75
Anchor Reinf. and Supplementary Reinf. Is Present? No
hef ,EffecƟve embedment depth of anchor 15.748 in
FooƟng Concrete, f'c 4 ksi
Concrete Cracked? Yes Concrete Breakout Failure Mode

λ , Concrete lightweight factor 1

Design Formulation
<ACI318-14 SecƟon 17.4.2.1>
(Units: psi,in) <ACI318-14 SecƟon 17.4.2.2>
(Units: psi,in) <ACI318-14 SecƟon 17.4.2.2>
<ACI318-14 SecƟon 17.4.2.3>
(Demand/Capacity RaƟo)
ψed,N <ACI318-14 Eq 17.4.2.5>
ψc,N = 1 <ACI318-14 SecƟon 17.4.2.6>
ψcp,N = 1 <ACI318-14 SecƟon 17.4.2.7>
kc = 24 <ACI318-14 SecƟon 17.4.2.2>
ANc <ACI318-14 SecƟon 17.4.2.1>
ANco <ACI318-14 SecƟon 17.4.2.1>
Ca,min (Minimum edge distance)
Ca,max (Maximum edge distance)
Nua (Anchor tension force under current load combo)
φ = 0.7 <ACI318-14 SecƟon 17.3.3>

Anchors Check
No. ID CriƟcal LC Ca,min [in] Ca,max [in] hef [in] ANc [in²] ψed,N Nb [kips] 0.75φNcb [kips] Nua [kips] DCR Check
1 20 LRFD01 6.311 17.311 15.748 558.001 0.78 0.035 9.713 0 0 Pass
2 20 LRFD01 6.311 17.311 15.748 558.001 0.78 0.035 9.713 0 0 Pass
3 20 LRFD03 6.311 17.311 15.748 558.001 0.78 0.035 9.713 9.675 1 Fail
4 20 LRFD03 6.311 17.311 15.748 558.001 0.78 0.035 9.713 9.675 1 Fail

ColumnBase Demo v4.0.0 Design Report (www.PCEESoft.com) Page 4 of 5


Concrete Side-face Blowout Strength Demand/Capacity Ratio: 0 Check: Pass

General Data
Design Provisions ACI318-14 SecƟon 17.4.4
Controlling Load Combo Controlling LoadCombo
Strength ReducƟon Factor(Seismic) 0.75
Anchors Type Headed Bolts
Anchors Head Type Hex
hef, EffecƟve embedment depth of anchor 15.748 in
FooƟng Concrete, f'c 4 ksi Sideface Blowout Failure Mode
λ, Concrete lightweight factor 1

Design Formulation
(Otherwise the side-face blowout failure is not applicable for the anchor)
<ACI318-14 Eq 17.4.4.1>
(ModificaƟon factor, ACI318-14 SecƟon 17.4.4.1)
(Demand/Capacity RaƟo)
Ca1 (Minimum edge distance)
Ca2 (Minimum edge distance in the direcƟon perpendicular to ca1)
Abrg (Net bearing area of the head of anchor)
φ = 0.7 <ACI318-14 SecƟon 17.3.3>
Nua (Anchor tension force under current load combo)

Anchors Check
No. ID CriƟcal LC Ca1 [in] hef >2.5Ca1 Ca2 [in] α Abrg [in²] 0.75 αφNsb [kips] Nua [kips] DCR Check
1 20 LRFD01 6.311 No N.A N.A N.A N.A N.A - -
2 20 LRFD01 6.311 No N.A N.A N.A N.A N.A - -
3 20 LRFD01 6.311 No N.A N.A N.A N.A N.A - -
4 20 LRFD01 6.311 No N.A N.A N.A N.A N.A - -

ColumnBase Demo v4.0.0 Design Report (www.PCEESoft.com) Page 5 of 5