Chapter 14

14.1.2 Using the Mode


0011-1721

<Operation at the time of Bit SW> <Operation at the time of Parameter>

AUTO AUTO
TEXT/PHOTO 01 TEXT/PHOTO 01
1) Selecting User Mode 1) Selecting User Mode
Press the User mode key, 2key, 8key, Press the User mode key, 2key, 8key,
User mode key sequentially. User mode key sequentially.

#SSSW #SSSW

2) Selecting a Menu Item


Select the Menu item using the
2) Press the OK key. left/right arrow key.
#SSSW #NUMERIC Param.
001 000000000
3) Selecting a Menu Item
Press the OK key. Or, press
3) Press the OK key.
the keypad after pushing # key.
#NUMERIC Param.
001 0
#SSSW
033 000000000
4) Selecting a Prarameter
Select the Prarameter using the
4) Selecting a Bit Switch
left/right arrow key.
Select the bit using the
left/right arrow key. #NUMERIC Param.
002 0
#SSSW
033 000000000 5) Registering/Setting Data
5) Registering/Setting Data Enter data using the keypad,
Enter data using the keypad, and press the OK key.
and press the OK key. #3 NUMER I C P a r am.
002 10
#SSSW
033 000000001 6) Press the Stop key or User
6) Press the Stop key or User mode key to end service mode.
mode key to end service mode.
F-14-1

14.2 Default settings


14.2.1 Service Mode Menus
0011-1722

#SSSW
No. Initial setting Function
SW01 0 error/copy control
SW02 not used
SW03 0 echo remedy setting
SW04 10000000 communication fault remedy setting
SW05 0 standard function (DIS signal) setting
SW06 - SW11 not used
SW12 10 page timer setting
SW13 0 meter/inch resolution setting
SW14 1 inch/meter resolution setting
SW15 - SW27 not used
SW28 0 V.8/V.34 protocol settings
SW29 not used
SW30 00000000(JPN)/ Assigning a New Dial Tone Detection Method
00000011(EURO)/
00000001(Other
country/region)
SW31- SW32 not used

14-2