MODULENS G
FLOOR-STANDING GAS CONDENSING BOILERS
FROM 3.4 TO 35.9KW
AGC…/B 160 SL: for heating and DHW production
by 160 litre enamelled calorifier with coil placed
AGC 15-25-35: for heating only to the left or to the right of the boiler
AGC…/V 100 HL: for heating and DHW production AGC…/V 220 SHL: for heating and DHW
by 100 litre stratification calorifier placed under production by 220 litre enamelled solar calorifier
the boiler placed under the boiler
AGC…/V 160 SL: for heating and DHW production AGC…/B 220 SHL: for heating and DHW
by 160 litre enamelled calorifier with coil placed production by 220 litre enamelled solar calorifier
under the boiler placed to the left or to the right of the boiler

AGC 15-25-35 AGC…/V 100 HL AGC…/V 160 SL AGC…/B 160 SL AGC…/V 220 SHL AGC…/B 220 SHL

The MODULENS boiler range includes models for heating only and models
comprising boilers combined with 100, 160 or 200 litre calorifiers for DHW
AGC 15-25-35: production. MODULENS boilers are fully equipped as standard with:
For heating only - a modulating heating pump of class A (high performance energy) (except
on model AGC 35),
- a 18 litre expansion vessel, an automatic air vent, a draining valve, the
heating safety valve, a heating/DHW reversal valve,
AGC…/V…, and B/…:
For heating and domestic hot - an DIEMATIC iSystem control panel with new ergonomics allows connected
water with options, the command and control of up to 3 circuits (an traditional or
solar DHW circuit) according to the outside temperature. It also allows the
optimum management of systems combining various heating generators
(boiler + heat pump or + solar system…) or the control of cascade with 2
to 10 boilers.
Condensing
Various air/flue gas connection configurations are possible: we offer solutions
for connection by horizontal or vertical forced flue, to a chimney, in bi-flow or
to a collective flue system.
CONDITIONS OF USE
All natural gases Boilers:
Propane Max. operating temperature: 90°C
Max. operating pressure: 3bar
Power supply: 230V/50Hz
Protection index: IP 21
Calorifiers:
AGC…/V 220 SHL Max. operating pressure: 10bar
and /B 200 SHL
Max. operatng temperature: 95°C
Solar max. operating pressure: 6bar (220 SHL)
HOMOLOGATION
EC identification No: B23p, B33, C13x, C33x, C93x, C53, C43x, C83x
0085CM0178
GAZ CATEGORY
Fitted and preset to operate on natural gases. Propane operating with
conversion kit (option).

ADVANCE
112978 Modulens G GB.indd 1 13/10/11 14:51
PRESENTATION
The AGC boilers in the MODULENS range are factory-tested 160 SL (Standard Load) calorifier and a connecting kit under the
and delivered fully assembled. They are prefitted to run on type boiler to form a uniform «column» (…/V 160 SL) or placed to
H natural gas but can also be converted to run on propane the left or to the right of the boiler (…/B 160 SL). The calorifier
(using the conversion kit available as an option). is equipped with a TAS (Titan Active System®) anode, which does
not consume matter, guaranteeing protection of the tank, a
The AGC 15-25-35 boilers are fitted as standard with a draining valve, a coupling for a circulation loop, boiler/calorifier
modulating heating pump of class A (except on AGC 35, this connecting pipes, a DHW sensor, adjustable feet.
boiler is fitted with standard modulating pump), an expansion The 160 SL calorifier is an enamelled coil calorifier. It is insulated
vessel 18 litre (except on AGC 35), an automatic air vent, a with high density injected CFC-free polyurethane foam.
draining valve, a heating safety valve, a hydroblock, a heating/
DHW reversal valve. The AGC…/V 220 SHL and AGC…/B 220 SHL models
comprise the boilers AGC 15-25-35 combined with the 220 litre
The AGC…/V 100 HL models comprise the boilers AGC 220 SHL (Solar High Load) calorifier and a connecting kit under
15-25-35 combined with the 100 litre 100 HL (High Load) the boiler to form a uniform «column» (…/V 220 SHL) or placed
calorifier and a connecting kit under the boiler to form a uniform to the left or to the right of the boiler (…/B 220 SHL). The solar
«column». The calorifier is equipped with a TAS (Titan Active calorifier is equipped with a TAS (Titan Active System®) anode,
System®) anode, which does not consume matter, guaranteeing which does not consume matter, guaranteeing protection of the
protection of the tank, a draining valve, a coupling for a tank, a draining valve, a coupling for a circulation loop, 1 DHW
circulation loop, boiler/calorifier connecting pipes, 1 DHW sensor, adjustable feet.
sensor, adjustable feet. It is also equipped with a complete solar unit: pump, expansion
The 100 HL calorifier is a high performance, enamelled vessel (delivered separately – Package ER 229), safety unit, air
stratification calorifier, equipped with a plate exchanger vent, glycol tank, solar control system.
combined with a load pump. It is insulated with high density The 220 SHL solar calorifier is an enamelled stratification
injected CFC-free polyurethane foam. calorifier equipped with a plate exchanger combined with a load
pump and a coil for connection to a solar system. It is insulated
The AGC…/V 160 SL and AGC…/B 160 SL models with high density injected CFC-free polyurethane foam.
comprise the boilers AGC 15-25-35 combined with the 160 litre

HIGH LEVELS OF PERFORMANCE


- Annual operating efficiency up to 109%,
- NOx classification: 5 according to EN 483,
- Low noise level,
- Low polluant emissions:
MODULENS AGC… NOx* (mg/kWh) CO** (ppm)
AGC 15… 33 51
AGC 25… 38 94
AGC 35… 42 114
* according to EN 297 A3 ** by Qmax.

STRONG POINTS
- Compact boilers of modular design with the same aesthetic - Electronic ignition and ionisation flame check,
as the DHW calorifiers with which they can be combined, - DIEMATIC iSystem control panel that can be used in all
- New compact and ultra-responsive exchanger in cast installation configurations, including the most complex; it
aluminium/silicium alloy, is designed to command and control a direct circuit as
- Perfect adaptation of boiler output to actual needs thanks standard. With the addition of a sensor, it can be used
to the stainless steel gas burner with complete premixing, to regulate a primary circuit with mixing valve; with the
modulating from 22 to 100% output, fitted with a silencer on addition of a PCB + sensor, it can control a secondary circuit
the air intake, with mixing valve. Installation of a DHW sensor enables
- Internal lighting that comes on automatically when the regulation with priority to a DHW circuit. It is specifically
appliance is powered up to facilitate maintenance work, designed to enable the optimisation of management of
- Fan fitted with a nonreturn valve on the air intake to run with combined systems (solar systems). The position of the control
pressurised evacuation systems (3 CEp), module is adjustable for ease of use regardless of height.

112978 Modulens G GB.indd 2 13/10/11 14:51


MODELS AVAILABLE
BOILER FOR HEATING ONLY
Boiler type Tank Solar
Models Tank
AGC 15 AGC 25 AGC 35 connecting-set expansion vessel
AGC…
JA 2 - - - - -
Fully equiped boiler

- JA 3 - - - -
AGC_Q0001

- - JA 4 - - -

BOILER WITH DHW TANK PLACED UNDER THE BOILER


Boiler type Tank Solar
Models Tank
AGC 15 AGC 25 AGC 35 connecting-set expansion vessel
AGC…/V 100 HL ER 225 JA 9
JA 2 - - + +
With an 100 litre DHW
enamelled stratification calorifier - JA 3 - + + -
« High Load »
AGC_Q0002

- - JA 4 + +

AGC…/V 160 SL ER 223 JA 8


JA 2 - - + +
With an 160 litre DHW
calorifier with enamelled coil - JA 3 - + + -
« Standard Load »
AGC_Q0003

- - JA 4 + +

AGC…/V 220 SHL ER 220 JA 9 ER 229


JA 2 - - + + +
With an 220 litre DHW
enamelled stratification calorifier - JA 3 - + + +
« High Load » equipped with a
AGC_Q0005

solar coil - - JA 4 + + +

BOILER WITH DHW TANK PLACED TO THE LEFT OR TO THE RIGHT OF THE BOILER
Boiler type Tank-boiler Solar
Models Tank connecting-
AGC 15 AGC 25 AGC 35 expansion vessel
set
AGC…/B 160 SL ER 223 ER 228
JA 2 - - + +
With an 160 litre DHW
calorifier with enamelled coil - JA 3 - + + -
« Standard Load »
AGC_Q0004

- - JA 4 + +

AGC…/B 220 SHL ER 220 ER 216 ER 229


JA 2 - - + + +
With an 220 litre DHW
enamelled stratification calorifier - JA 3 - + + +
« High Load » equipped with a
AGC_Q0006

solar coil - - JA 4 + + +

112978 Modulens G GB.indd 3 13/10/11 14:51


TECHNICAL SPECIFICATIONS
MAIN DIMENSIONS (IN MM AND INCHES)
➩ AGC 15, 25, 35
600 680
240 132 16
74

70 55 57 55 918
844
1 6 128,5
5 2
3

AGC_F0001B
55
251 4 254
150 7 112
(1)
8
520 61 436 105,5 121,5

➩ AGC 15, 25, 35/V 100 HL Calorifier 100 HL


600 680
240 132 16

74

1482
1 2
128,5
70 167
3
55
121,5
1408 4 105,5 7
8

AGC_Q0024
11
818
10 12
816 680
715 598
245 70 40
AGC_F0002B

300 Stratification calorifier equipped:


13 - with a load pump
(1) 87 - with a plate exchanger
520 61 436
- with a draining valve
723 - with protection of the enamelled tank by TAS
(Titan Active System®)
- with a DHW sensor

➩ AGC 15, 25, 35/V 160 SL Calorifier 160 SL


600 680
240 132 16

74

1762
1 2
128,5
70 167
3
55
121,5
1688 4 105,5 7
8
11 1098
10 12
956
1096
994 880
245 70 40
AGC_Q0025
AGC_F0003B

300

87
13 DHW coil calorifier equipped with:
(1)
- a draining valve
520 61 436 - a imposed current anode TAS (Titan Active Système®) to
723
protect the enamelled tank
- a DHW sensor
Legend
  Heating flow/return direct circuit G 3/4
Domestic cold water inlet G 3/4  Evacuation of combustion products and air inlet
 Gas inlet Ø G 1/2 Domestic hot water outlet G 3/4 pipe Ø 60/100mm
 Condensate drain, siphon provided, PVC pipe DHW circulation loop return G 3/4
Ø 24 x 19mm (with package ER 218: Recirculation kit for 100 HL (1) Feet adjustable from 0 to 20mm
  Primary return/inlet from independent calorifier calorifiers or with package ER 219: Recirculation kit G: Cylindrical external thread (water tightness by flat
(with package JA 10 – option) G 3/4 for 160 SL and 220 SHL calorifier – options) gasket)
 Heating flow/return circuit with mixing valve Drain tap connection for pipe Ø ext. 14mm
G 3/4 (with package JA 6: Internal pipe kit with  Primary inlet from solar coil Cu 18mm
motorised 3-way valve and pump, or with package  Primary outlet from solar coil Cu 18mm
4 JA 7: Pipes only kit – options)

112978 Modulens G GB.indd 4 13/10/11 14:52


TECHNICAL SPECIFICATIONS
➩ AGC 15, 25, 35/ B 160 SL
600 600 680 245 70
240 132 11 12 16
10
74

880
70 167 917,5
844 920
1 128,5
2
3

AGC_F0004B
300 55
251 254
13 4 150
87 7 112
(1) (1)
8
520 520 61 436 105,5 121,5
723

➩ AGC 15, 25, 35/ V 220 SHL Calorifier 220 SHL *


600 680
240 132 16

74

2042
1 2
128,5
70 167
3
55
121,5
1968 4 105,5 7
8
15 11
14 10 12
115
157
AGC_F0001B

245 70 40
1375 1378

1274 1236
1160
1135
1116
AGC_F0005B

300

AGC_Q0026A
13
(1)
88

520 61 436
723
Solar stratification calorifier equipped:
- a DHW load pump,
- a plate exchanger,
- a draining valve,
- a imposed current anode TAS (Titan Active Système®) to
protect the enamelled tank,
- a DHW sensor,
- a solar unit (pump, expansion vessel, safety unit, air vent,
glycol tank, solar control system).
* For AGC…/B 220 SHL must the expansion vessel be wall
mounted

➩ AGC 15, 25, 35/ B 220 SHL


723 245 70 40
680 15 11
600 600
132 157 10 12
14 115

18,5
16
240
74

1160
1116

70 167 918
844 1201 1
2 128,5
3
AGC_F0006B

300 55
4 251 254
13
88 150 7 112
(1) (1)
8
520 520 61 436 105,5 121,5

Legend: see page 4

112978 Modulens G GB.indd 5 13/10/11 14:52


TECHNICAL SPECIFICATIONS
DESCRIPTION
AGC…/V 100 HL Detail of the boiler’s internal
lighting
Control panel in service
position
iSystem control panel

AGC_Q0010
Sealed chamber
(see below) Exchanger/burner

Siphon
3bar heating safety valve
Heating/DHW
reversal valve
Motorized 3 way valve
(option)
Modulating heating

MCA_Q0014
circulator (class A)

Calorifier 100 litres


Plate exchanger Heating body (section view)

DHW load pump


Injected CFC-free
polyurethane foam insulation
AGC_Q0007

Drain tap connection

AGC_Q0027
Sealed chamber

Air/flue gas connection Air intake silencer


Ø 60/100mm with
measuring point

Automatic air vent

Ignition and ionisation


electrodes Expansion vessel 18 litres
(except with AGC 35)

Fan

Gas safety unit Exchanger in cast


aluminium/silicium alloy with
stainless steel gas burner
with complete premixing
Condensates collector
AGC_Q0028

112978 Modulens G GB.indd 6 13/10/11 14:52


TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Type generator: Boiler type: condensing
- AGC… : heating only Burner: modulating with complete premixing
- AGC…/V… : heating + DHW with calorifier placed under Energy used: natural gas or propane
the boiler Combustion evacuation: chimney or forced flue
- AGC…/B… : heating + DHW with calorifier placed to the Min. flow temperature: 20°C
left or to the right of the boiler Min. return temperature: 20°C
Ref. CE certificate: CE-0085CM0178

➪ Boiler specifications
15 25 35
Boiler type AGC… 15/V… 25/V… 35/V…
15/B… 25/B… 35/B…
Useful output at 50/30°C Pn in heating mode (min.-max.) kW 3.4-15.8 5.6-25.5 7.0-35.9
Efficiency 100% Pn, at average temp. 70°C % 96.5 96.3 96.9
at… % output 100% Pn, at return temp. 30°C % 105.3 102.0 102.2
and… °C water temp. 30% Pn, at return temp. 30°C % 108.5 108.0 108.2
Nominal water flow at Pn, Δt = 20K m3/h 0.62 1.04 1.46
Stand-by losses at Δt = 30K W 78 78 85
Auxiliary electrical power at Pmin./Pn (without circul. pump) W 18/31 18/46 18/53
Power heating pump at Pmin./Pn W 5/70 5/70 45/120
Useful output at 80/60°C (min.-max.) kW 3.0-14.5 5.0-24.1 6.3-34.0
Manometric height available heating circuit mbar 545 295 180
Gas flow at Pn gas H m3/h 1.59/1.85 3.10/3.61 3.71/4.32
(15°C-1 013mbar) propane m3/h 0.61 1.20 1.44
Flue gas temperature (min.-max.) °C 30-65 30-80 30-75
Mass flue gas output (min.-max.) kg/h 5.3-25.2 8.9-42.1 11.1-57.3
CO2 content on natural gas H (min.-max.) % 8.4-8.8 8.4-8.8 8.6-9.0
Pressure available at the boiler outlet Pa 80 130 140
Water capacity l 1.9 1.9 2.5
Net weight AGC 15, 25 and 35 kg 60 60 54

➪ Specifications domestic hot water


15/V 160 SL 25/V 160 SL 35/V 160 SL 15/V 220 SHL 25/V 220 SHL 35/V 220 SHL
Boiler type AGC… 15/V 100 HL 25/V 100 HL 35/V 100 HL
15/B 160 SL 25/B 160 SL 35/B 160 SL 15/B 220 SHL 25/B 220 SHL 35/B 220 SHL
DHW calorifier capacity l 100 100 100 160 160 160 220 220 220
Exchanged power kW 15 28 32 15 28 32 15 28 32
Flow over 10 min at Δt = 30K l/10 min 210 255 280 235 240 245 200 240 260
Flow per hour at Δt = 35K l/h 370 690 790 370 690 790 370 690 790
Spec. flow at Δt = 30K* l/min 21 25.5 28 20 24 24.5 20 24 26
Auxiliary electrical power in DHW mode** W 70/45 70/63 120/85 70 70 120 70/45 70/63 120/85
DHW losses through the outer casing
W 62 62 62 80 80 80 117 117 117
at Δt = 45K
Cooling constant Wh/24h.l.K 0.34 0.34 0.34 0.26 0.26 0.26 0.28 0.28 0.28
Net weight kg 113 113 107 140/142 140/142 134/136 185/190 185/190 179/184
Domestic performance at room temp. 20°C, cold water temp.10°C, hot water temp. at Pn 45°C, primary hot water temp. 80°C, stockage temp. 60°C
* compliance with EN 13203
** primary side/secondary side

➪ Solar component data

Boiler type AGC… /V 220 SHL and /B 220 SHL


Solar volume/back-up volume l 135/85
Solar exchanger capacity l 8.4
Solar exchange surface m2 1.25

112978 Modulens G GB.indd 7 13/10/11 14:52


CONTROL PANEL DIEMATIC iSYSTEM
CONTROL PANEL DIEMATIC iSystem
The DIEMATIC iSystem control panel is a very advanced circuits in total and each of these circuits can be fitted with a CDI
control panel, with new control ergonomics which includes or CDR D.iSystem remote control (optional).
electronic programmable regulation as standard to modulate Connection of a domestic hot water sensor makes it possible to
the boiler temperature by activating the modulating burner programme and regulate a DHW circuit.
according to the outside temperature and the room temperature This control system has been specifically developed to enable
if a CDI D.iSystem, CDR D.iSystem or simplified interactive remote optimum management of systems combining various
control is connected (optional). heating generators (boiler + heat pump or + solar system…).
As standard, DIEMATIC iSystem is capable of automatically It allows the installer to set the parameters for the entire heating
operating a central heating installation with a direct circuit installation regardless of its degree of complexity.
without mixing valve and 1 circuit with mixing valve (the flow In the context of larger installations, it is also possible to connect
sensor - package AD 199 - must be ordered separately, 2 and as many as 10 boilers in cascade.
however). It is possible to install additional circuits through the regulation
VM iSystem.
By connecting another “PCB + sensor for 1 valve circuit” option
(package AD 249), it is therefore possible to control up to 3

Temperature setting key


(heating, DHW, swimming Large LCD display
pool)
Selection key for the On/Off switch
heating, Summer and Winter
DHW and Auto operating
modes depending on the
programme, Day, Night,

AGC_Q0008
Holidays, Manual
Forced load key for DHW
production

Rotary setting button and push button:


- By turning it, you can scroll down the
Key menu or modify a value
- To access the various menus or - By pressing it, you can confirm a selection
parameters, or value modification
- For programming, reset, which
vary as selections are made

DIEMATIC iSystem CONTROL PANEL OPTIONS


Domestic hot water sensor - Package AD 212
This is used for regulating the DHW temperature as
a priority and programming of domestic hot water
production with an independent calorifier.
8518Q022

Outlet sensor downstream of the valve - Package AD 199


This sensor is required to connect the first circuit
with mixing valve to a boiler fitted with a DIEMATIC
GT220_Q0002

iSystem control panel.

PCB + sensor for 1 mixing valve - Package AD 249


This is used to control a mixing valve with an can receive 1 “PCB + sensor” option, enabling it to
electromechanical or electrothermal motor. The control 1 additional mixing valve.
MCA_Q0013

PCB is inserted into the DIEMATIC iSystem panel


connected by pin connections. DIEMATIC iSystem

Sensor for storage tank - Package AD 250


Includes 1 sensor for managing a storage tank with
a boiler fitted with a DIEMATIC iSystem control
MCA_Q0012

panel.

112978 Modulens G GB.indd 8 13/10/11 14:52


CONTROL PANEL DIEMATIC iSYSTEM
DIEMATIC iSystem CONTROL PANEL OPTIONS
CDI D. iSystem interactive remote control - Package AD 254
AD 253/254
CDR D. iSystem interactive “radio” remote control (without transmitter/receiver radio) - Package AD 253
Radio boiler module DIEMATIC iSystem (transmitter/receiver) - Package AD 252

CALENTA_Q0005
These are used to override all instructions from the In the case of the CDR D.iSystem, the data are
AD 252
DIEMATIC iSystem control panel from the room in transmitted by radio waves from the place where
which they are installed. In addition, they enable the the CDR D.iSystem is installed to the transmitter/
self-adaptability of the heating regime for the circuit receiver box (package AD 252) placed close to the
concerned (one CDI D.iSystem or CDR D.iSystem per boiler.
8666Q172A

circuit).

Simplified remote control with room sensor - Package FM 52


This is used from the room in which it is installed - room temperature program and instruction
to override certain instructions from the DIEMATIC override. It is also used to enable the self-
8575Q037

iSystem panel: adaptability of the heating curve for the circuit


concerned (1 remote control per circuit).
BUS connection cable (length 12m) - Package AD 134
The BUS cable is used to make the connection connection of a DIEMATIC VM iSystem control unit
between 2 boilers fitted with the DIEMATIC iSystem or a telemonitoring network transmitter.
8227Q020

control panel in a cascade installation, as well as the

Radio outside temperature sensor - Package AD 251


AD 251
Boiler radio module (radio transmitter) - Package AD 252
8575Q034

The radio outside temperature sensor can be If this sensor is used:


delivered as optional equipment for systems in - With a wire connection remote control (AD 254 or
which the installation of the external wire connection FM 52), it is necessary to order the “Boiler radio
AD 252
sensor delivered with DIEMATIC iSystem control module”
panel would be too complex. - With a radio remote control (AD 253), already
combined with a “boiler radio module” (AD 252),
8666Q172A

control of a second module is not necessary.

VM iSystem wall-hung control unit - Package AD 281


The VM iSystem electronic control system, according to the outside temperature (sensor
incorporated in a wall-mounted box, is used to to be ordered separately – package FM 46)
manage and control two heating circuits and a independently of the generator.
DHW circuit and each of the heating circuits may - VM iSystem can control a boiler via OpenTherm
be a direct circuit or a circuit with motorised 3-way (existing outlet on VM iSystem) for a boiler
mixing valve. equipped with an OpenTherm bus, or as «ON/
It is possible to interlink up to 20 VM iSystem control OFF» via the auxiliary contact for any other
systems and thus configure numerous combinations, generator (burner, HP, wood-fired boiler…).
regardless of the type of installation: - VM iSystem can control a cascade of boilers:
- VM iSystem can be used in combination with an • Equipped with a DIEMATIC control panel
existing generator to control additional heating • Equipped with an OpenTherm BUS via an
VM_Q0001

and DHW circuits. interface board (1 board per generator).


- VM iSystem can also be used fully autonomously
on its own to control heating and DHW circuits

112978 Modulens G GB.indd 9 13/10/11 14:53


BOILER OPTIONS
HYDRAULIC CONNECTING KITS
➩ For AGC…/V 100 HL, V 160 SL and V 220 SHL
JA 11 Central connection kit - Package JA 11
Left connection kit - Package JA 12
Right connection kit - Package JA 13
Connection kits with prefitted water and gas stop JA 11), to the right (Package JA 13) or to the left
cocks, integrated disconnector and DHW safety unit (Package JA 12).
and boiler connecting pipes in the middle (Package
AGC_Q0018

JA 12
AGC_Q0019

JA 13
AGC_Q0020

Connecting pipes between the “3-way valve” kit (JA 6) or the adapter kit (JA 7) and a hydraulic
connection kit - Package JA 35
This kit comprises two ribbed pipes and two « external 3 way valve » (JA 7) to the connection kit
AGC_Q0022

hydraulic valves. Allowed to connect the « internal used (JA 34 or JA 11, 12 or 13).
3 way valve » kit (JA 6) or the adapter kit for
➩ For AGC… (heating only) and AGC…/B 160 SL and AGC…/B 220 SHL
Solo connecting kit - Package JA 34
This board is delivered with the water and gas boiler and is used to carry the gas inlet, the heating
valves prefitted. It is arrached to the back of the return and the heating flow to the top.
AGC_Q0021A

HYDRAULIC MODULES
Using the various elements presented below, it is possible to put
together complete hydraulic connection kits depending on the
installation to be constructed.
List of packages required by the type of installation to achieve:
1 radiator circuit or 1 direct underfloor 1 circuit with mixing valve + 1 radiator 3 circuits, 2 with mixing valve
heating circuit direct circuit (or underfloor circuit)

EA67 EA67
Type of installation ou ou
EA136 EA136
to achieve JA 6 $& $& $& $&

or or
AGC_F0022A

EA59

JA 6 JA 7

AGC… JA 7 + EA 59
AGC…/V… — JA 6 + 2 x EA 67 or EA 136 (1)
AGC…/B…
PCB AD 249
Options needed — — Sensor AD 199
(1) The boiler/collector connections should be made by the installer
10

112978 Modulens G GB.indd 10 13/10/11 14:53


BOILER OPTIONS
HYDRAULIC MODULES
Internal 3-way valve kit (with engine) - Package JA 6
Permits the connection of a circuit with mixing valve. includes the sensor.
This kit will be integrated under the casing and
Specifications of the pump in the 3-way valve kit - Package JA 6 :
Manometric height (mCE)
5

AGC_F0023
2
 Stage 1
AGC_Q0013A

1 3
1  Stage 2
0
2  Stage 3
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Flow rate(m3/h)

Adapter kit for external 3-way valve - Package JA 7


Allows the connection of two circuits with mixing
valve on the outside of the boiler.
AGC_Q0014

Hydraulic module for 1 circuit with valve


°C °C
- Package EA 67 (with electronic pump) or
- Package EA 136 (with a high performance energy pump class A)
350 These moduls are fully assembled, insulated thermometers built into the gate valves and a non-
and tested, fitted with an pump, a motorized return valve built into the outlet valve.
3-way mixing valve, a differential safety valve,
8575F074B

250

Technical specifications of heating circulator fitted to the hydraulic modules:


EA 67 EA 136
Manometric
EA 67 Manometric
EA 135/136
EA 136 Pressure
Pressure
height available height
available m m
(Qi¡la¡f_ D
HUJL
H kPa 7
kPa 7
\
$ $ 60 Max 60
% 6 6
&
' 50 5 50 5
(
) 40 4 40 4
*

30 3 30 3

20 2 20 2

10 1 10 1
8875F118B
Flow Flow
0 0
Min rate 0 0 rate
0.0 0.5 1.0 1.5 2.0 2.5 3,0 3,5 m3/h
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 m3/h

Constant pressure Proportional pressure Pump on “AutoAdapt” position

Collector for 2 circuits - Package EA 59


8575F074B

125
With an installation with 2 or 3 circuits.
500

Set of 2 walls consoles for hydraulic modules - Package EA 74


These consoles are used to fix the hydraulic modules this set of consoles is compulsory so the fitter can
for direct circuit or circuit with mixing valve to the construct the boiler/module connection.
8575F074B

wall. With a unit with 3 modules, the installation of

Set connection G in R (1” and 3/4”) - Package BH 84


DTG130_Q0021

This kit includes 2 G 1-R 1 fittings and 1 G 3/4-R from flat gasket fittings to conical fittings (water
3/4 fitting with gaskets and can be used to switch tightness in the threading).

11

112978 Modulens G GB.indd 11 13/10/11 14:53


BOILER OPTIONS
OTHER ACCESSORIES
HWPlus 70 decoupling cylinder - Package HC 28
For all installations with 2 circuits (1 direct circuit with 1 manual air vent and 1 drainage valve. It can
+ 1 valve circuit) or for installations in cascade up be pivoted on itself for connection to the left or right
to 70kW is the use of decoupling cylinder highly of the boiler. He is delivered insulated and fitted
8575Q026
recommended. The HWPlus 70 cylinder is delivered with a bracket to secure it to the wall.

Cleaning tool boiler body - Package HR 45


Connects to a classic vacuum cleaner and allows an
easy boiler body cleaning.
MCA_F0015

DU 13
Condensates neutralisation system with pump - Package DU 13
Condensates neutralisation system without pump - Package BP 52
C210_Q0014

Neutralisation granules (10kg) Ref. 94225601

BP 52
8538F050

1,5 to 2%

HC 33
Condensate neutralisation tank - Package HC 33
Wall bracket for neutralisation tank - Package HC 34
8531Q027

Granule refill for neutralisation tank (2kg) - Package HC 35


The materials used for the condensates flow pipes Principle: The acidic condensates flow through a
HC 34
must be appropriate; otherwise the condensates tank filled with granules before being discharged
must be neutralised. into the waste water network.
8531Q028A

Flue gas thermostat - Package JA 38


This thermostat cut the boiler when the flue gas
temperature exceeds 110°C.
AGC_Q0023

Propane conversion kit for AGC 15…, / V…, /B… - Package JA 39


Propane conversion kit for AGC 25…, / V…, /B… - Package JA 40
Propane conversion kit for AGC 35…, / V…, /B… - Package JA 41

12

112978 Modulens G GB.indd 12 13/10/11 14:53


BOILER OPTIONS
STOVE FITTING ACCESSORIES SPECIFIC TO BOILERS AGC
Adapter Ø 80/125mm - Package HR 38
Is fitted instead and in place of the Ø 60/100mm Ø 80/125mm or a boiler connection kit if connected
fitting deliverred mounted on the boiler. It enables to the collective flue system duct.

MCA_Q0004
the direct connection of a vertical forced flue

Adapter bi-flow Ø 60/100mm to 2 x Ø 80mm - Package DY 868

Reducing elbow - Package JA 43


When, for reasons of space, the horizontal forced (Ø 60/100mm) on the boiler and thus allows a
flue with its elbow cannot be installed, this elbow height saving of 70 mm.
EGC_Q0009

is mounted instead and in place of the fitting

Connecting kit Ø 80/125mm on collective flue system duct - Package DY 887


If connected to a collective flue system duct, package DY 887, wich incorporates the adapter
the adapter Ø 60/100mm delivered with the Ø 80/125mm.
MCX_F0008

boiler should be removed and replaced by

FOR DHW PRODUCTION


Domestic hot water sensor - Package AD 212
This is used for regulating the DHW temperature as production with an independent calorifier.
a priority and programming of domestic hot water
8518Q022

Magnesium anode kit for tank protection - Package EA 103


For DHW calorifier models AGC…/V… and permanently activated (in secondary homes, for
DTG130_Q0017

AGC…/B…, if the “Titan Active System®” self- example).


adapting current anode fitted as standard is not

Kit DHW expansion vessel for AGC…/V 100 HL and /V 160 SL - Package ER 233
Can be integrated in the boiler, prevents water loss
DTG130_Q0031

during tank reheating in DHW mode.

Recirculation kit for calorifier 100 HL - Package ER 218


AGC_F0031A

Recirculation kit for calorifiers 160 SL and 220 SHL - Package ER 219
AGC_F0030

Connecting kit for the connection of a independent calorifer - Package JA 10


For AGC… (heating only), this kit mounted under
the casing of the boiler allows the connection of a
AGC_F0031A

independent calorifier.

13
BOILER OPTIONS
FLAT COLLECTORS RECOMMENDED WITH BOILER AGC…/V 220 SHL AND AGC…/B 220 SHL
Number of people living in the home from to
For installation on roof or terrace (1) For installation into the roof (1)
Flat solar collectors or solar collector field
Package 2 x PRO 2,3 ST (4.2 m2) 2 x PRO 2,3 IT (4.2 m2)
(«roof» packs) recommended:
EC 583 or EC 518 (2) (3) EC 589 or EC 528 (2) (3)

"High performances" heat transfer fluid


Package EG 100 EG 100
(20 litre, - 26°C)

(1) For other options, refer to current catalogue or “DIETRISOL” technical manual.
(2) Type of anchorage fittings to select depending of the roof type (refer to current catalogue or “DIETRISOL” technical manual).
(3) According to delivery: horizontally or vertically.

INFORMATION REQUIRED FOR INSTALLATION


STATUTORY INSTRUCTIONS ON INSTALLATION AND MAINTENANCE
The installation and maintenance of the appliance in both be carried out by a qualified professional in compliance with the
residential buildings and establishments open to the public must statutory texts of the codes of pratice in force.

LOCATION
The AGC condensing boilers must be installed in premises Compliance with a minimum distance between the flue gas
protected from frost, wich can also be ventilate. evacuation system or the boiler and combustible materials
(furniture, for example) is not necessary.


In order to avoid damage to boilers, it is necessary to prevent the contamination of combustion air by chloride and/or
fluoride compounds, which are particularly corrosive.
These compounds are present, for example, in aerosol spray cans, paints, solvents, cleaning products, washing powders/
liquids, detergents, glues, snow clearing salts, etc.

It is therefore necessary:
- To avoid sucking in air discharged from premises using such products: hairdressers, dry cleaners, industrial premises (solvents), premises
containing refrigeration systems (risk of leaking refrigeration fluid), etc.
- To avoid the storage of such products close to boilers.
Please note that, if the boiler and/or its peripherals become corroded by chloride and/or fluoride compounds, our
contractual warranty cannot be invoked. Please note that, if the boiler and/or its peripherals become corroded by chloride
and/or fluoride compounds, our contractual warranty cannot be invoked.

Ventilation
(chimney connection only B23p ) Note:
The cross-section of the boiler room ventilation (through) wich - For boilers connected to a concentric forced flue (type C13x or
combustive air is taken in must comply with the prevailing C33x connections) ventilation of the installation premises is not
standard. necessary, unless the gas supply includes one or more mechanical
connections (cf. prevailing standard).
- See also recommendations in the «Flue Systems» booklet.

14

112978 Modulens G GB.indd 14 13/10/11 14:53


INFORMATION REQUIRED FOR INSTALLATION
GAS CONNECTION
Compliance with prevailing instructions and regulations is The diameters of the pipes must be defined according to the
mandatory. In all cases, a sectional valve is fitted as close as prevailing regulations:
possible to the boiler. This valve is delivered in the hydraulic - 20mbar on natural gas H,
connection kits available as optional equipment. A gas filter must - 37mbar on propane.
be fitted to the boiler inlet.

Certificate of conformity
The installer is required to draw up a certificate of conformity appro-
ved by the ministers responsible for construction and gas safety.

ELECTRICAL CONNECTION
This must comply with the prevailing national or even local Note:
instructions and regulations. - The sensor cables must be separated from the 230V circuits
The boiler must be powered by an electrical circuit comprising by at least 10cm
an omnipolar switch with an opening gap > 3mm. Protect the - In order to protect the pump antifreeze and cleaning
connection to the mains with a 6A fuse. functions, we recommend not switching off the boiler at the
mains switch.

HYDRAULIC CONNECTION
Important: The principle of a condensing boiler is to recycle necessary to size the heating surfaces in such a way as to
the energy contained in the water vapour in the combustion obtain low return temperatures, below the dew point (e.g.
gases (latent vaporisation heat). Consequently, to achieve underfloor heating, low temperature radiators, etc.) during the
an annual operating efficiency in the order of 109%, it is entire heating period.

Connection to the heating circuit


AGC boilers must only be used in closed circuit heating Furthermore, it is important to protect central heating
installations. The central heating systems must be cleaned installations against the risk of corrosion, scaling and
to eliminate the debris (copper, strands, brazing flux) linked microbiological growth by using a corrosion inhibitor adapted
to the installation of the system and deposits that can cause to all types of systems (steel, cast iron radiators, heated floor,
malfunctions (noise in the system, chemical reaction between PER).
metals). More particularly, if fitting a boiler to an existing
The water treatment products used must comply with
installation, it is strongly recommended that you clear sludge
regulations.
out of the system before installing the new boiler.

Manometric height available for heating circuit


AGC 15-25/… AGC 35/…
Manometric height Manometric height
(mbar) (mbar)

800 800

700 700

600 15 kW
6T 20K 20 kW 600
25 kW
6T 20K 6T 20K
500 500

400 400 35 kW
6T 20K
300 300

200
AGC_F0035

AGC_F0034

200

100 100

0 623 834 1037 0 1465


0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Flow rate (l/h) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Flow rate (l/h)

Condensates discharge
The siphon provided must be connected to the waste water be in corrosion-resistant material. An optional condensates
discharge system. The connection must be removable and the neutralisation system is available (package HC 33 see page 9).
flow of condensates visible. The connections and pipes must

15

112978 Modulens G GB.indd 15 13/10/11 14:53


EXAMPLES OF INSTALLATIONS
The examples presented below cannot cover the full range of in the boiler room according to its specificities. In all cases, it
installation scenarios which may be encountered. is necessary to abide by the codes of practice and prevailing
Their purpose is to draw the attention to the basic rules to regulations.
be followed. A certain number of control and safety devices Attention : For the connection of domestic hot water, a sleeve
(some of which are already integrated as standard in AGC made of steel, cast iron or any other insulating material must
boilers) are represented but it is ultimately up to installers, be interposed between the hot water outlet and these pipes
experts, consultant engineers and design departments to take to prevent any corrosion to the connections, if the distribution
the final decision on the safety and control devices to be used pipes are made of copper.

AGC…with 1 radiator circuit (direct) + 1 DHW circuit with independent calorifier, outside sensor, remote control

21 )0

9
67 32
27
64
9
27
-$
GAS
9 9
7
7
24
16 9
230V 3
50Hz 56
17 33
11/26
30
46 29 9
-$ 27 25
68 28
9

AGC_F0025
$*& %/

AGC…/V 100 HL with 1 underfloor heating circuit (direct), outside sensor, interactive remote control (wire)

21

&'5'L6\VWHP
      

           

13:42
$872

02'(

$'

7
230V 
50Hz 3 9
32
17
 27

GAS 9
 27


28
29 9
-$


(5

68
17
AGC_F0026A

AGC .../V 100 HL

16 Legend: see page 18

112978 Modulens G GB.indd 16 13/10/11 14:53


EXAMPLES OF INSTALLATIONS
AGC…/V 160 SL with 1 radiator circuit (direct) + 1 underfloor heating circuit with mixing valve (integrated in the boiler),
outside sensor, interactive wireless remote control
&'5'L6\VWHP
$' 


 

13:42


 





 





 




$872

02'(

21
$'

51 9
BUS
32
$'
27 7
9 16 3
64 27
-$ 17

GAS
27

11/26
-
-$
46

28
9 29
-$

(5

230V 68
50Hz 17

AGC_F0027A
$*&96/

AGC…/V 220 SHL with 1 radiator circuit (direct) + 2 circuits with mixing valve, 2 flat collectors PRO 2,3 , outside sensor,
2 interactive wireless remote control
$' (&
$'

21

BUS

&'5'L6\VWHP &'5'L6\VWHP
             

                       

13:42 13:42
$872 $872

02'( 02'(

$' $'

65 65
9
X
AU L

67 44 7 L

44
64 32 16 [$'
23 3
$' 27
4 4 -$ (*
27 27 9 17
-$ GAS 11/26 (*
'C 'C 'C 'C

9 9 9 9 27

46
11b 11b
($ 10 ($ 10 87 4
($ -$
75
%+ 89
130
(5 61

84
230V
28 68 88
9 29 85 50Hz
AGC_F0029C

17 114

$*&96+/
Legend: see page 18 17

112978 Modulens G GB.indd 17 13/10/11 14:53


EXAMPLE OF INSTALLATION
AGC 35/V 220 SHL with 2 circuits with mixing valve, 2 flat collectors PRO 2,3, outside sensor, 2 interactive wireless remote
control
(&

$'
BUS

$'
21
&'5'L6\VWHP &'5'L6\VWHP
             

                       

13:42 13:42
$872

02'( $' $872

02'( $'

65 65
9 7
44 44
32 7 +& 3
23 8
$' 27 -$ X
AU L

(*
4 4 L

27 27 9 GAZ 17 (*
11/26 [$'
'C 'C 'C 'C

9 9 9 9 27

46
11b 11b
($ 10 ($ 10 87 4
-$
($ 75
9 29
%+ 28 130 89
(5 61

18 50 9 84
16 13 230V
68 88 50Hz
85

AGC_F0032B
17 114

$*&96+/

Note: in this example, the limited manometric height of the pump fitted to the AGC 35 requires the use of a disconnecting cylinder (option HC 28).

Legend
3 Safety valve 3 bar 25 Primary outlet on the DHW tank 46 3 way-directional 84 Stop valve with releas non return
4 Pressure gauge exchanger valve with motor valve
7 Automatic air vent 26 Domestic water load pump reversing 85 Solar circuit pump (to connect to
8 Manual air vent 27 Non-return valve 50 Disconnector the solar control)
9 Isolation valve 28 Domestic cold water inlet 51 Thermostatic valve 87 Safety valve sealed and calibrated
11 Electronic heating pump 29 Pressure reducer 56 DHW circulation loop return to 6 bar
11a Electronic heating pump for direct 30 Sealed safety device calibrated to 61 Thermometer 88 Solar expansion tank 18 l
circuit 7 bars 64 Radiator circuit (gentle heat 89 Recepient for heat transfer fluid
11b Electronic heating pump 32 (Optional) DHW loop pump radiators, for example) 109 Thermostatic mixing valve
for circuit with 33 DHW temperature sensor 65 Low temperature circuit (underfloor 114 Solar circuit drainage valve
mixing valve 35 Decoupling cylinder (available as heating, for example) (note: propyleneglycol)
13 Flush valve an option - see page 12) 67 Manual valve 130 Degasser with manual purge
16 Expansion tank 39 Injection pump 68 Condensates neutralisation system (Airstop)
21 Outside sensor 44 65°C limiter thermostat with 72 Hydraulic bypass
23 Outlet temperature sensor after manual reset for underfloor 75 Domestic water pump
mixing valve heating 79 Primary outlet of the solar
24 Primary inlet on the DHW tank exchanger
exchanger

18

112978 Modulens G GB.indd 18 13/10/11 14:53


INFORMATION REQUIRED FOR INSTALLATION
AIR/FLUE GAS CONNECTION
For the use of the air/flue gas connection pipes and the rules on
installation, see details of the various configurations in the current
product catalogue.

Classification

 Configuration C13x: Air/flue gas connection by means of


concentric pipes to a horizontal terminal (so-called forced
flue)
Lmax = L1+L2 Lmax
 Configuration C33x: Air/flue gas connection by means of
concentric pipes to a vertical terminal (roof outlet)
L1 Lmax
or
C43x C33x  Configuration C93x: Air/flue gas connection using
Lmax concentric pipes in the boiler room and single pipes in
L2 12 2
the chimney (combustive air with counter current in the
Lmax chimney)
Lmax or
Lmax
L2
 Air/flue gas connection using concentric pipes in the boiler
C13x C43x
C33x
room and single “flex” pipes in the chimney (combustive air
1 2 12 with counter current in the chimney)
 Configuration C53: Separate air and flue gas connection
L1
1m 1m
Lmax using a bi-flow adapter and single pipes (combustive air
1m
taken from outside)
max max
max

Lmax =
C33x
 Configuration B23p: Connection to a chimney (combustive
L1+L2 C53 B23P C43x C93x C93x
air taken from the boiler room)

AGC_F0033
5 6 12 3 4 2
 Configuration C43x : Connection to a collective flue system
conduit

TABLE OF MAXIMUM AIR/FLUE GAS PIPE LENGHTS ADMISSIBLE ACCORDING TO BOILER TYPE
Lmax of the connecting pipes in m
Type of air/flue gas connection MODULENS AGC
15 25 35
Concentric pipes connected to a horizontal termina (PPS) Ø 60/100mm 12 3.5 3.5
C13x
Ø 80/125mm 12.3 20 17.6
Concentric pipes connected to a vertical terminal (PPS) Ø 60/100mm 13 4.9 -
C33x
Ø 80/125mm 10.7 20 19
Pipes Ø 60/100mm 15 8.1 9
- concentric in the boiler room, Ø 60mm
- single in the chimney (combustive air with
counter current) (PPS) C93x Ø 60/100mm
9.9 20 18
C33x Ø 80mm
Ø 80/120mm - - 20
Ø 80mm
Pipes
- concentric in the boiler room, C93x Ø 80/125mm
- “flex” in the chimney (combustive air with counter current) 11 .1 20 20
C33x Ø 80mm
(PPS)

Bi-flow adapter and separate single air/flue gas Ø 60/100mm


C53 40 40 32
pipes (combustive air taken from outside) (Alu) to 2 x Ø 80mm

In the chimney rigid or flex, (combustive air taken from the Ø 80mm (rigid) 40 40 40
premises) (PPS) B23p
Ø 80mm (flex) 40(1) 40 (1) 28 (1)
Collective flue system conduit for sealed boiler C43x To size such a system, contact the supplier of the collective flue system

(1) : Max. height in the flue pipe (C93x and B23p configurations) from the support elbow to the outlet musn’t exceed 25m for flex PPS. In
case of higher lengths, holding collars must be added by slices of 25m.

19

112978 Modulens G GB.indd 19 13/10/11 14:53


DESCRIPTION
MODULENS AGC…
FLOOR-STANDING GAS CONDENSING BOILER FOR CONNECTION TO A CHIMNEY OR A FORCED FLUE
Brand : De Dietrich AGC 15:_____kW
directive, NOx classification: 5 AGC 25:_____kW
Model : AGC 35: _____kW
AGC 15, 25, 35: for heating only
AGC 15, 25, 35/V 100 HL: for heating and domestic hot water Specific flow in DHW mode:
preparation by associated 100 litre DHW stratification calorifier AGC …/V 100 HL: _____/min
placed under the boiler. AGC …/V 160 SL and …/B 160 SL: _____l/min
AGC 15, 25, 35/V 160 SL and …/B 160 SL: for heating and AGC …/V 220 SHL and …/B 220 SHL: _____l/min
domestic hot water preparation by associated 160 litre DHW Boiler:
calorifier with coil placed under the boiler (…/V 160 SL) or Max. operating temperature: 90°C
placed to the left or to the right of the boiler(…/B 160 SL). Max. operating pressure: 3bar
AGC 15, 25, 35/V 220 SHL and …/V 220 SHL: for heating and Safety thermostat: 110°C
domestic hot water preparation by associated 220 litre Solar Calorifier:
DHW tank placed under the boiler (…/V 220 SHL) or placed to Max. operating temperature: 95°C
the left or to the right of the boiler(…/B 220 SHL). Max. operating pressure: 10bar
Homologation : B23p-B33-C13x-C33x-C93x-C53-C43x-C83x Solar calorifier max. operating pressure: 6bar (220 SHL)
Protection index: IP 21 Dimensions: _____ x _____ x _____ mm

10/2011 – 300027734 – 347.555.559 Strasbourg Companies Register – Document not contractually binding - Printed in France - OTT Imprimeurs 67310 Wasselonne - 112978
Power supply: 230V/50Hz Weight empty: ______kg
Useful output in heating mode at 50/30°C (max.)

DESCRIPTON
Complies with the requirements of European Directives. - Sensor for storage tank
New compact and ultra-responsive exchanger in cast Aluminium/ - CDI D. iSystem interactive remote control
Silicium alloy. - CDR D. iSystem interactive “radio” remote control
Stainless steel gas burner with complete premixing, modulating - Radio boiler module DIEMATIC iSystem
from 22 to 100% output, fitted with a silencer on the air intake. - Simplified remote control with room sensor
The DIEMATIC iSystem control panel is a control panel with - BUS connection cable
new control ergonomics and incorporates a programmable - Radio outside temperature sensor
electronic control system as standard. Suitable for managing - Boiler radio module
a direct circuit + 1 valve circuit (optional flow sensor). Capable of - Control unit VM iSystem
managing 1 DHW circuit (sensor optional) and 1 additional valve
circuit (PCB + sensor optional)and a DHW circuit. Boiler options
New ergonomics and optimisation of management of combined - Central connection kit
heating systems. - Left connection kit
Boiler delivered and prefitted with, a modulating heating pump - Right connection kit
of class A (except AGC 35), 3-bar safety valve, 18-litre expansion - Solo connection kit
vessel (except AGC 35), heating/DHW reversal valve, automatic - 3-way internal valve kit
air vent. - External circuit kit
- AGC …/V 100 HL: with enamelled, insulated 100 litre DHW - Hydraulic module with electronic pump
“High Load” calorifier placed under the boiler. Boiler/tank - Hydraulic module with a high performance energy pump class A
connecting pipes, tank protection with Titan Active System®, a - Collector for 2 hydraulic modules
drain valve and DHW sensor included. - Set of 2 walls consoles for hydraulic modules
- AGC …/V 160 SL and …/B 160 SL: with insulated 160 litre - Set connection G in R
DHW “Standard load” calorifier placed under the boiler (…/V - HWPlus 70 decoupling cylinder
160 SL) or placed to the left or to the right of the boiler(…/B - Cleaning tool boiler body
160 SL). Boiler/tank connectiong pipes, tank protection with Titan - Condensates neutralisation system with pump
Active System®, a drain valve and DHW sensor included. - Condensates neutralisation system without pump
- AGC …/V 220 SHL and …/B 220 SHL: with enamelled, - Neutralisation granules (10kg)
insulated 200 litre solar DHW calorifier placed under the - Condensate neutralisation tank
boiler (…/V 220 SHL) or placed to the left or to the right of - Wall bracket for neutralisation tank
the boiler(…/B 220 SHL). Boiler/tank connecting pipes, tank - Granule refill for neutralisation tank (2kg)
protection with Titan Active System®, a drain valve and DHW - Flue gas thermostat
sensor included. Pre-fitted with all the components required to - Propane conversion kit
connect and control a solar installation: solar station with pump, - Adapter Ø 80/125mm
expansion vessel, safety unit, solar regulation, degasser, glycol - Adapter bi-flow Ø 60/100mm to 2 x Ø 80mm
recovery tank. - Reducing elbow
Air/flue gas connection Ø 60/100 mm with measuring point. - Connecting kit Ø 80/125mm on collective flue system duct
- Magnesium anode for tank protection
Control panel options - Kit DHW expansion vessel for AGC .../V 100 HL and /V 160 SL
- Domestic hot water sensor - Recirculation kit for calorifier 100 HL
- Sensor for 1 mixing valve - Recirculation kit for calorifiers 160 SL and 220 SHL
- PCB + sensor for 1 mixing valve
DE DIETRICH THERMIQUE
S.A.S. with corporate capital of 22 487 610 €
57, rue de la Gare - 67580 Mertzwiller
Tél. +33 3 88 80 27 00 - Fax +33 3 88 80 27 99
www.dedietrich-heating.com

112978 Modulens G GB.indd 20 13/10/11 14:53