MODULENS G
FLOOR-STANDING GAS CONDENSING BOILERS
FROM 3.4 TO 35.9KW
AGC…/B 160 SL: for heating and DHW production
by 160 litre enamelled calorifier with coil placed
AGC 15-25-35: for heating only to the left or to the right of the boiler
AGC…/V 100 HL: for heating and DHW production AGC…/V 220 SHL: for heating and DHW
by 100 litre stratification calorifier placed under production by 220 litre enamelled solar calorifier
the boiler placed under the boiler
AGC…/V 160 SL: for heating and DHW production AGC…/B 220 SHL: for heating and DHW
by 160 litre enamelled calorifier with coil placed production by 220 litre enamelled solar calorifier
under the boiler placed to the left or to the right of the boiler
AGC 15-25-35 AGC…/V 100 HL AGC…/V 160 SL AGC…/B 160 SL AGC…/V 220 SHL AGC…/B 220 SHL
The MODULENS boiler range includes models for heating only and models
comprising boilers combined with 100, 160 or 200 litre calorifiers for DHW
AGC 15-25-35: production. MODULENS boilers are fully equipped as standard with:
For heating only - a modulating heating pump of class A (high performance energy) (except
on model AGC 35),
- a 18 litre expansion vessel, an automatic air vent, a draining valve, the
heating safety valve, a heating/DHW reversal valve,
AGC…/V…, and B/…:
For heating and domestic hot - an DIEMATIC iSystem control panel with new ergonomics allows connected
water with options, the command and control of up to 3 circuits (an traditional or
solar DHW circuit) according to the outside temperature. It also allows the
optimum management of systems combining various heating generators
(boiler + heat pump or + solar system…) or the control of cascade with 2
to 10 boilers.
Condensing
Various air/flue gas connection configurations are possible: we offer solutions
for connection by horizontal or vertical forced flue, to a chimney, in bi-flow or
to a collective flue system.
CONDITIONS OF USE
All natural gases Boilers:
Propane Max. operating temperature: 90°C
Max. operating pressure: 3bar
Power supply: 230V/50Hz
Protection index: IP 21
Calorifiers:
AGC…/V 220 SHL Max. operating pressure: 10bar
and /B 200 SHL
Max. operatng temperature: 95°C
Solar max. operating pressure: 6bar (220 SHL)
HOMOLOGATION
EC identification No: B23p, B33, C13x, C33x, C93x, C53, C43x, C83x
0085CM0178
GAZ CATEGORY
Fitted and preset to operate on natural gases. Propane operating with
conversion kit (option).
ADVANCE
112978 Modulens G GB.indd 1 13/10/11 14:51
PRESENTATION
The AGC boilers in the MODULENS range are factory-tested 160 SL (Standard Load) calorifier and a connecting kit under the
and delivered fully assembled. They are prefitted to run on type boiler to form a uniform «column» (…/V 160 SL) or placed to
H natural gas but can also be converted to run on propane the left or to the right of the boiler (…/B 160 SL). The calorifier
(using the conversion kit available as an option). is equipped with a TAS (Titan Active System®) anode, which does
not consume matter, guaranteeing protection of the tank, a
The AGC 15-25-35 boilers are fitted as standard with a draining valve, a coupling for a circulation loop, boiler/calorifier
modulating heating pump of class A (except on AGC 35, this connecting pipes, a DHW sensor, adjustable feet.
boiler is fitted with standard modulating pump), an expansion The 160 SL calorifier is an enamelled coil calorifier. It is insulated
vessel 18 litre (except on AGC 35), an automatic air vent, a with high density injected CFC-free polyurethane foam.
draining valve, a heating safety valve, a hydroblock, a heating/
DHW reversal valve. The AGC…/V 220 SHL and AGC…/B 220 SHL models
comprise the boilers AGC 15-25-35 combined with the 220 litre
The AGC…/V 100 HL models comprise the boilers AGC 220 SHL (Solar High Load) calorifier and a connecting kit under
15-25-35 combined with the 100 litre 100 HL (High Load) the boiler to form a uniform «column» (…/V 220 SHL) or placed
calorifier and a connecting kit under the boiler to form a uniform to the left or to the right of the boiler (…/B 220 SHL). The solar
«column». The calorifier is equipped with a TAS (Titan Active calorifier is equipped with a TAS (Titan Active System®) anode,
System®) anode, which does not consume matter, guaranteeing which does not consume matter, guaranteeing protection of the
protection of the tank, a draining valve, a coupling for a tank, a draining valve, a coupling for a circulation loop, 1 DHW
circulation loop, boiler/calorifier connecting pipes, 1 DHW sensor, adjustable feet.
sensor, adjustable feet. It is also equipped with a complete solar unit: pump, expansion
The 100 HL calorifier is a high performance, enamelled vessel (delivered separately – Package ER 229), safety unit, air
stratification calorifier, equipped with a plate exchanger vent, glycol tank, solar control system.
combined with a load pump. It is insulated with high density The 220 SHL solar calorifier is an enamelled stratification
injected CFC-free polyurethane foam. calorifier equipped with a plate exchanger combined with a load
pump and a coil for connection to a solar system. It is insulated
The AGC…/V 160 SL and AGC…/B 160 SL models with high density injected CFC-free polyurethane foam.
comprise the boilers AGC 15-25-35 combined with the 160 litre
STRONG POINTS
- Compact boilers of modular design with the same aesthetic - Electronic ignition and ionisation flame check,
as the DHW calorifiers with which they can be combined, - DIEMATIC iSystem control panel that can be used in all
- New compact and ultra-responsive exchanger in cast installation configurations, including the most complex; it
aluminium/silicium alloy, is designed to command and control a direct circuit as
- Perfect adaptation of boiler output to actual needs thanks standard. With the addition of a sensor, it can be used
to the stainless steel gas burner with complete premixing, to regulate a primary circuit with mixing valve; with the
modulating from 22 to 100% output, fitted with a silencer on addition of a PCB + sensor, it can control a secondary circuit
the air intake, with mixing valve. Installation of a DHW sensor enables
- Internal lighting that comes on automatically when the regulation with priority to a DHW circuit. It is specifically
appliance is powered up to facilitate maintenance work, designed to enable the optimisation of management of
- Fan fitted with a nonreturn valve on the air intake to run with combined systems (solar systems). The position of the control
pressurised evacuation systems (3 CEp), module is adjustable for ease of use regardless of height.
- JA 3 - - - -
AGC_Q0001
- - JA 4 - - -
- - JA 4 + +
- - JA 4 + +
solar coil - - JA 4 + + +
BOILER WITH DHW TANK PLACED TO THE LEFT OR TO THE RIGHT OF THE BOILER
Boiler type Tank-boiler Solar
Models Tank connecting-
AGC 15 AGC 25 AGC 35 expansion vessel
set
AGC…/B 160 SL ER 223 ER 228
JA 2 - - + +
With an 160 litre DHW
calorifier with enamelled coil - JA 3 - + + -
« Standard Load »
AGC_Q0004
- - JA 4 + +
solar coil - - JA 4 + + +
70 55 57 55 918
844
1 6 128,5
5 2
3
AGC_F0001B
55
251 4 254
150 7 112
(1)
8
520 61 436 105,5 121,5
74
1482
1 2
128,5
70 167
3
55
121,5
1408 4 105,5 7
8
AGC_Q0024
11
818
10 12
816 680
715 598
245 70 40
AGC_F0002B
74
1762
1 2
128,5
70 167
3
55
121,5
1688 4 105,5 7
8
11 1098
10 12
956
1096
994 880
245 70 40
AGC_Q0025
AGC_F0003B
300
87
13 DHW coil calorifier equipped with:
(1)
- a draining valve
520 61 436 - a imposed current anode TAS (Titan Active Système®) to
723
protect the enamelled tank
- a DHW sensor
Legend
Heating flow/return direct circuit G 3/4
Domestic cold water inlet G 3/4 Evacuation of combustion products and air inlet
Gas inlet Ø G 1/2 Domestic hot water outlet G 3/4 pipe Ø 60/100mm
Condensate drain, siphon provided, PVC pipe DHW circulation loop return G 3/4
Ø 24 x 19mm (with package ER 218: Recirculation kit for 100 HL (1) Feet adjustable from 0 to 20mm
Primary return/inlet from independent calorifier calorifiers or with package ER 219: Recirculation kit G: Cylindrical external thread (water tightness by flat
(with package JA 10 – option) G 3/4 for 160 SL and 220 SHL calorifier – options) gasket)
Heating flow/return circuit with mixing valve
Drain tap connection for pipe Ø ext. 14mm
G 3/4 (with package JA 6: Internal pipe kit with Primary inlet from solar coil Cu 18mm
motorised 3-way valve and pump, or with package Primary outlet from solar coil Cu 18mm
4 JA 7: Pipes only kit – options)
880
70 167 917,5
844 920
1 128,5
2
3
AGC_F0004B
300 55
251 254
13 4 150
87 7 112
(1) (1)
8
520 520 61 436 105,5 121,5
723
74
2042
1 2
128,5
70 167
3
55
121,5
1968 4 105,5 7
8
15 11
14 10 12
115
157
AGC_F0001B
245 70 40
1375 1378
1274 1236
1160
1135
1116
AGC_F0005B
300
AGC_Q0026A
13
(1)
88
520 61 436
723
Solar stratification calorifier equipped:
- a DHW load pump,
- a plate exchanger,
- a draining valve,
- a imposed current anode TAS (Titan Active Système®) to
protect the enamelled tank,
- a DHW sensor,
- a solar unit (pump, expansion vessel, safety unit, air vent,
glycol tank, solar control system).
* For AGC…/B 220 SHL must the expansion vessel be wall
mounted
18,5
16
240
74
1160
1116
70 167 918
844 1201 1
2 128,5
3
AGC_F0006B
300 55
4 251 254
13
88 150 7 112
(1) (1)
8
520 520 61 436 105,5 121,5
AGC_Q0010
Sealed chamber
(see below) Exchanger/burner
Siphon
3bar heating safety valve
Heating/DHW
reversal valve
Motorized 3 way valve
(option)
Modulating heating
MCA_Q0014
circulator (class A)
AGC_Q0027
Sealed chamber
Fan
➪ Boiler specifications
15 25 35
Boiler type AGC… 15/V… 25/V… 35/V…
15/B… 25/B… 35/B…
Useful output at 50/30°C Pn in heating mode (min.-max.) kW 3.4-15.8 5.6-25.5 7.0-35.9
Efficiency 100% Pn, at average temp. 70°C % 96.5 96.3 96.9
at… % output 100% Pn, at return temp. 30°C % 105.3 102.0 102.2
and… °C water temp. 30% Pn, at return temp. 30°C % 108.5 108.0 108.2
Nominal water flow at Pn, Δt = 20K m3/h 0.62 1.04 1.46
Stand-by losses at Δt = 30K W 78 78 85
Auxiliary electrical power at Pmin./Pn (without circul. pump) W 18/31 18/46 18/53
Power heating pump at Pmin./Pn W 5/70 5/70 45/120
Useful output at 80/60°C (min.-max.) kW 3.0-14.5 5.0-24.1 6.3-34.0
Manometric height available heating circuit mbar 545 295 180
Gas flow at Pn gas H m3/h 1.59/1.85 3.10/3.61 3.71/4.32
(15°C-1 013mbar) propane m3/h 0.61 1.20 1.44
Flue gas temperature (min.-max.) °C 30-65 30-80 30-75
Mass flue gas output (min.-max.) kg/h 5.3-25.2 8.9-42.1 11.1-57.3
CO2 content on natural gas H (min.-max.) % 8.4-8.8 8.4-8.8 8.6-9.0
Pressure available at the boiler outlet Pa 80 130 140
Water capacity l 1.9 1.9 2.5
Net weight AGC 15, 25 and 35 kg 60 60 54
AGC_Q0008
Holidays, Manual
Forced load key for DHW
production
panel.
CALENTA_Q0005
These are used to override all instructions from the In the case of the CDR D.iSystem, the data are
AD 252
DIEMATIC iSystem control panel from the room in transmitted by radio waves from the place where
which they are installed. In addition, they enable the the CDR D.iSystem is installed to the transmitter/
self-adaptability of the heating regime for the circuit receiver box (package AD 252) placed close to the
concerned (one CDI D.iSystem or CDR D.iSystem per boiler.
8666Q172A
circuit).
JA 12
AGC_Q0019
JA 13
AGC_Q0020
Connecting pipes between the “3-way valve” kit (JA 6) or the adapter kit (JA 7) and a hydraulic
connection kit - Package JA 35
This kit comprises two ribbed pipes and two « external 3 way valve » (JA 7) to the connection kit
AGC_Q0022
hydraulic valves. Allowed to connect the « internal used (JA 34 or JA 11, 12 or 13).
3 way valve » kit (JA 6) or the adapter kit for
➩ For AGC… (heating only) and AGC…/B 160 SL and AGC…/B 220 SHL
Solo connecting kit - Package JA 34
This board is delivered with the water and gas boiler and is used to carry the gas inlet, the heating
valves prefitted. It is arrached to the back of the return and the heating flow to the top.
AGC_Q0021A
HYDRAULIC MODULES
Using the various elements presented below, it is possible to put
together complete hydraulic connection kits depending on the
installation to be constructed.
List of packages required by the type of installation to achieve:
1 radiator circuit or 1 direct underfloor 1 circuit with mixing valve + 1 radiator 3 circuits, 2 with mixing valve
heating circuit direct circuit (or underfloor circuit)
EA67 EA67
Type of installation ou ou
EA136 EA136
to achieve JA 6 $& $& $& $&
or or
AGC_F0022A
EA59
JA 6 JA 7
AGC… JA 7 + EA 59
AGC…/V… — JA 6 + 2 x EA 67 or EA 136 (1)
AGC…/B…
PCB AD 249
Options needed — — Sensor AD 199
(1) The boiler/collector connections should be made by the installer
10
AGC_F0023
2
Stage 1
AGC_Q0013A
1 3
1 Stage 2
0
2 Stage 3
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Flow rate(m3/h)
250
30 3 30 3
20 2 20 2
10 1 10 1
8875F118B
Flow Flow
0 0
Min rate 0 0 rate
0.0 0.5 1.0 1.5 2.0 2.5 3,0 3,5 m3/h
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 m3/h
125
With an installation with 2 or 3 circuits.
500
This kit includes 2 G 1-R 1 fittings and 1 G 3/4-R from flat gasket fittings to conical fittings (water
3/4 fitting with gaskets and can be used to switch tightness in the threading).
11
DU 13
Condensates neutralisation system with pump - Package DU 13
Condensates neutralisation system without pump - Package BP 52
C210_Q0014
BP 52
8538F050
1,5 to 2%
HC 33
Condensate neutralisation tank - Package HC 33
Wall bracket for neutralisation tank - Package HC 34
8531Q027
12
MCA_Q0004
the direct connection of a vertical forced flue
Kit DHW expansion vessel for AGC…/V 100 HL and /V 160 SL - Package ER 233
Can be integrated in the boiler, prevents water loss
DTG130_Q0031
Recirculation kit for calorifiers 160 SL and 220 SHL - Package ER 219
AGC_F0030
independent calorifier.
13
BOILER OPTIONS
FLAT COLLECTORS RECOMMENDED WITH BOILER AGC…/V 220 SHL AND AGC…/B 220 SHL
Number of people living in the home from to
For installation on roof or terrace (1) For installation into the roof (1)
Flat solar collectors or solar collector field
Package 2 x PRO 2,3 ST (4.2 m2) 2 x PRO 2,3 IT (4.2 m2)
(«roof» packs) recommended:
EC 583 or EC 518 (2) (3) EC 589 or EC 528 (2) (3)
(1) For other options, refer to current catalogue or “DIETRISOL” technical manual.
(2) Type of anchorage fittings to select depending of the roof type (refer to current catalogue or “DIETRISOL” technical manual).
(3) According to delivery: horizontally or vertically.
LOCATION
The AGC condensing boilers must be installed in premises Compliance with a minimum distance between the flue gas
protected from frost, wich can also be ventilate. evacuation system or the boiler and combustible materials
(furniture, for example) is not necessary.
In order to avoid damage to boilers, it is necessary to prevent the contamination of combustion air by chloride and/or
fluoride compounds, which are particularly corrosive.
These compounds are present, for example, in aerosol spray cans, paints, solvents, cleaning products, washing powders/
liquids, detergents, glues, snow clearing salts, etc.
It is therefore necessary:
- To avoid sucking in air discharged from premises using such products: hairdressers, dry cleaners, industrial premises (solvents), premises
containing refrigeration systems (risk of leaking refrigeration fluid), etc.
- To avoid the storage of such products close to boilers.
Please note that, if the boiler and/or its peripherals become corroded by chloride and/or fluoride compounds, our
contractual warranty cannot be invoked. Please note that, if the boiler and/or its peripherals become corroded by chloride
and/or fluoride compounds, our contractual warranty cannot be invoked.
Ventilation
(chimney connection only B23p ) Note:
The cross-section of the boiler room ventilation (through) wich - For boilers connected to a concentric forced flue (type C13x or
combustive air is taken in must comply with the prevailing C33x connections) ventilation of the installation premises is not
standard. necessary, unless the gas supply includes one or more mechanical
connections (cf. prevailing standard).
- See also recommendations in the «Flue Systems» booklet.
14
Certificate of conformity
The installer is required to draw up a certificate of conformity appro-
ved by the ministers responsible for construction and gas safety.
ELECTRICAL CONNECTION
This must comply with the prevailing national or even local Note:
instructions and regulations. - The sensor cables must be separated from the 230V circuits
The boiler must be powered by an electrical circuit comprising by at least 10cm
an omnipolar switch with an opening gap > 3mm. Protect the - In order to protect the pump antifreeze and cleaning
connection to the mains with a 6A fuse. functions, we recommend not switching off the boiler at the
mains switch.
HYDRAULIC CONNECTION
Important: The principle of a condensing boiler is to recycle necessary to size the heating surfaces in such a way as to
the energy contained in the water vapour in the combustion obtain low return temperatures, below the dew point (e.g.
gases (latent vaporisation heat). Consequently, to achieve underfloor heating, low temperature radiators, etc.) during the
an annual operating efficiency in the order of 109%, it is entire heating period.
800 800
700 700
600 15 kW
6T 20K 20 kW 600
25 kW
6T 20K 6T 20K
500 500
400 400 35 kW
6T 20K
300 300
200
AGC_F0035
AGC_F0034
200
100 100
Condensates discharge
The siphon provided must be connected to the waste water be in corrosion-resistant material. An optional condensates
discharge system. The connection must be removable and the neutralisation system is available (package HC 33 see page 9).
flow of condensates visible. The connections and pipes must
15
AGC…with 1 radiator circuit (direct) + 1 DHW circuit with independent calorifier, outside sensor, remote control
21 )0
9
67 32
27
64
9
27
-$
GAS
9 9
7
7
24
16 9
230V 3
50Hz 56
17 33
11/26
30
46 29 9
-$ 27 25
68 28
9
AGC_F0025
$*& %/
AGC…/V 100 HL with 1 underfloor heating circuit (direct), outside sensor, interactive remote control (wire)
21
&'5'L6\VWHP
13:42
$872
02'(
$'
7
230V
50Hz 3 9
32
17
27
GAS 9
27
28
29 9
-$
(5
68
17
AGC_F0026A
13:42
$872
02'(
21
$'
51 9
BUS
32
$'
27 7
9 16 3
64 27
-$ 17
GAS
27
11/26
-
-$
46
28
9 29
-$
(5
230V 68
50Hz 17
AGC_F0027A
$*&96/
AGC…/V 220 SHL with 1 radiator circuit (direct) + 2 circuits with mixing valve, 2 flat collectors PRO 2,3 , outside sensor,
2 interactive wireless remote control
$' (&
$'
21
BUS
&'5'L6\VWHP &'5'L6\VWHP
13:42 13:42
$872 $872
02'( 02'(
$' $'
65 65
9
X
AU L
67 44 7 L
44
64 32 16 [$'
23 3
$' 27
4 4 -$ (*
27 27 9 17
-$ GAS 11/26 (*
'C 'C 'C 'C
9 9 9 9 27
46
11b 11b
($ 10 ($ 10 87 4
($ -$
75
%+ 89
130
(5 61
84
230V
28 68 88
9 29 85 50Hz
AGC_F0029C
17 114
$*&96+/
Legend: see page 18 17
$'
BUS
$'
21
&'5'L6\VWHP &'5'L6\VWHP
13:42 13:42
$872
02'( $'
65 65
9 7
44 44
32 7 +& 3
23 8
$' 27 -$ X
AU L
(*
4 4 L
27 27 9 GAZ 17 (*
11/26 [$'
'C 'C 'C 'C
9 9 9 9 27
46
11b 11b
($ 10 ($ 10 87 4
-$
($ 75
9 29
%+ 28 130 89
(5 61
18 50 9 84
16 13 230V
68 88 50Hz
85
AGC_F0032B
17 114
$*&96+/
Note: in this example, the limited manometric height of the pump fitted to the AGC 35 requires the use of a disconnecting cylinder (option HC 28).
Legend
3 Safety valve 3 bar 25 Primary outlet on the DHW tank 46 3 way-directional 84 Stop valve with releas non return
4 Pressure gauge exchanger valve with motor valve
7 Automatic air vent 26 Domestic water load pump reversing 85 Solar circuit pump (to connect to
8 Manual air vent 27 Non-return valve 50 Disconnector the solar control)
9 Isolation valve 28 Domestic cold water inlet 51 Thermostatic valve 87 Safety valve sealed and calibrated
11 Electronic heating pump 29 Pressure reducer 56 DHW circulation loop return to 6 bar
11a Electronic heating pump for direct 30 Sealed safety device calibrated to 61 Thermometer 88 Solar expansion tank 18 l
circuit 7 bars 64 Radiator circuit (gentle heat 89 Recepient for heat transfer fluid
11b Electronic heating pump 32 (Optional) DHW loop pump radiators, for example) 109 Thermostatic mixing valve
for circuit with 33 DHW temperature sensor 65 Low temperature circuit (underfloor 114 Solar circuit drainage valve
mixing valve 35 Decoupling cylinder (available as heating, for example) (note: propyleneglycol)
13 Flush valve an option - see page 12) 67 Manual valve 130 Degasser with manual purge
16 Expansion tank 39 Injection pump 68 Condensates neutralisation system (Airstop)
21 Outside sensor 44 65°C limiter thermostat with 72 Hydraulic bypass
23 Outlet temperature sensor after manual reset for underfloor 75 Domestic water pump
mixing valve heating 79 Primary outlet of the solar
24 Primary inlet on the DHW tank exchanger
exchanger
18
Classification
Lmax =
C33x
Configuration B23p: Connection to a chimney (combustive
L1+L2 C53 B23P C43x C93x C93x
air taken from the boiler room)
AGC_F0033
5 6 12 3 4 2
Configuration C43x : Connection to a collective flue system
conduit
TABLE OF MAXIMUM AIR/FLUE GAS PIPE LENGHTS ADMISSIBLE ACCORDING TO BOILER TYPE
Lmax of the connecting pipes in m
Type of air/flue gas connection MODULENS AGC
15 25 35
Concentric pipes connected to a horizontal termina (PPS) Ø 60/100mm 12 3.5 3.5
C13x
Ø 80/125mm 12.3 20 17.6
Concentric pipes connected to a vertical terminal (PPS) Ø 60/100mm 13 4.9 -
C33x
Ø 80/125mm 10.7 20 19
Pipes Ø 60/100mm 15 8.1 9
- concentric in the boiler room, Ø 60mm
- single in the chimney (combustive air with
counter current) (PPS) C93x Ø 60/100mm
9.9 20 18
C33x Ø 80mm
Ø 80/120mm - - 20
Ø 80mm
Pipes
- concentric in the boiler room, C93x Ø 80/125mm
- “flex” in the chimney (combustive air with counter current) 11 .1 20 20
C33x Ø 80mm
(PPS)
In the chimney rigid or flex, (combustive air taken from the Ø 80mm (rigid) 40 40 40
premises) (PPS) B23p
Ø 80mm (flex) 40(1) 40 (1) 28 (1)
Collective flue system conduit for sealed boiler C43x To size such a system, contact the supplier of the collective flue system
(1) : Max. height in the flue pipe (C93x and B23p configurations) from the support elbow to the outlet musn’t exceed 25m for flex PPS. In
case of higher lengths, holding collars must be added by slices of 25m.
19
10/2011 – 300027734 – 347.555.559 Strasbourg Companies Register – Document not contractually binding - Printed in France - OTT Imprimeurs 67310 Wasselonne - 112978
Power supply: 230V/50Hz Weight empty: ______kg
Useful output in heating mode at 50/30°C (max.)
DESCRIPTON
Complies with the requirements of European Directives. - Sensor for storage tank
New compact and ultra-responsive exchanger in cast Aluminium/ - CDI D. iSystem interactive remote control
Silicium alloy. - CDR D. iSystem interactive “radio” remote control
Stainless steel gas burner with complete premixing, modulating - Radio boiler module DIEMATIC iSystem
from 22 to 100% output, fitted with a silencer on the air intake. - Simplified remote control with room sensor
The DIEMATIC iSystem control panel is a control panel with - BUS connection cable
new control ergonomics and incorporates a programmable - Radio outside temperature sensor
electronic control system as standard. Suitable for managing - Boiler radio module
a direct circuit + 1 valve circuit (optional flow sensor). Capable of - Control unit VM iSystem
managing 1 DHW circuit (sensor optional) and 1 additional valve
circuit (PCB + sensor optional)and a DHW circuit. Boiler options
New ergonomics and optimisation of management of combined - Central connection kit
heating systems. - Left connection kit
Boiler delivered and prefitted with, a modulating heating pump - Right connection kit
of class A (except AGC 35), 3-bar safety valve, 18-litre expansion - Solo connection kit
vessel (except AGC 35), heating/DHW reversal valve, automatic - 3-way internal valve kit
air vent. - External circuit kit
- AGC …/V 100 HL: with enamelled, insulated 100 litre DHW - Hydraulic module with electronic pump
“High Load” calorifier placed under the boiler. Boiler/tank - Hydraulic module with a high performance energy pump class A
connecting pipes, tank protection with Titan Active System®, a - Collector for 2 hydraulic modules
drain valve and DHW sensor included. - Set of 2 walls consoles for hydraulic modules
- AGC …/V 160 SL and …/B 160 SL: with insulated 160 litre - Set connection G in R
DHW “Standard load” calorifier placed under the boiler (…/V - HWPlus 70 decoupling cylinder
160 SL) or placed to the left or to the right of the boiler(…/B - Cleaning tool boiler body
160 SL). Boiler/tank connectiong pipes, tank protection with Titan - Condensates neutralisation system with pump
Active System®, a drain valve and DHW sensor included. - Condensates neutralisation system without pump
- AGC …/V 220 SHL and …/B 220 SHL: with enamelled, - Neutralisation granules (10kg)
insulated 200 litre solar DHW calorifier placed under the - Condensate neutralisation tank
boiler (…/V 220 SHL) or placed to the left or to the right of - Wall bracket for neutralisation tank
the boiler(…/B 220 SHL). Boiler/tank connecting pipes, tank - Granule refill for neutralisation tank (2kg)
protection with Titan Active System®, a drain valve and DHW - Flue gas thermostat
sensor included. Pre-fitted with all the components required to - Propane conversion kit
connect and control a solar installation: solar station with pump, - Adapter Ø 80/125mm
expansion vessel, safety unit, solar regulation, degasser, glycol - Adapter bi-flow Ø 60/100mm to 2 x Ø 80mm
recovery tank. - Reducing elbow
Air/flue gas connection Ø 60/100 mm with measuring point. - Connecting kit Ø 80/125mm on collective flue system duct
- Magnesium anode for tank protection
Control panel options - Kit DHW expansion vessel for AGC .../V 100 HL and /V 160 SL
- Domestic hot water sensor - Recirculation kit for calorifier 100 HL
- Sensor for 1 mixing valve - Recirculation kit for calorifiers 160 SL and 220 SHL
- PCB + sensor for 1 mixing valve