Sei sulla pagina 1di 8

Fire Pump Systems in NFPA 20 Standard

ETN YN Series
Experience Green Engineering
With our R&D, production, and installation By blending advanced pump features with
experience of more than 35 years in the pump innovative technologies, we offer high-quality, high-
technologies field, we protect you and your performance, energy-efficient, environmentally-
investments without compromising from quality friendly, and low-cost products to the end users.
with our expert sales and after-sales services.
ETNA, which set off with the vision of offering
We offer complete solutions for building sustainable products, is preferred in prestigious
infrastructures with our wide product range projects in both Turkey and the world and is used
including in-line dry rotor circulating pumps, end- reliably.
suction norm pumps, horizontal-vertical multi-stage
centrifuge pumps, waste water drainage pumps,
booster systems for residential and commercial
buildings, fire pumps, and booster systems in line
with TSE EN 12845 and NFPA 20 norms under the
brand of ETNA.

2
ETNA Fire Pump Systems

ETNA Fire Pumps Systems in Exact Answer to Your Needs


NFPA 20 Standard Our expert engineering team assists you in
ETNA Fire Pump Systems in NFPA 20 Standard identifying the right pump set for your project.
are designed and manufactured in line with the
Our products are delivered as full sets including an
norm no. 20 of NFPA (National Fire Protection
Association) of USA. electrical/diesel engine, a pilot pump, an electrical/
diesel control panel, an individual modular chassis
The main specification of the fire pumps in NFPA
20 standards are as follows: for each pump or connectors on a common chassis,
• 
Produced modularly with electrical or diesel and all the required accessories.
engines.

• 
End-suction EA series pumps are used.

• Hydraulic efficiency does not fall below 65% of


the nominal pressure in 150% capacity.

• Pump's closed valve value (zero flow) does


not exceed 140% of the nominal pressure.

• Suction and delivery collector speed do not


exceed 3m/s.

• Pump body is GG25 (cast pig), and pump fan


(impeller) is bronze, and tightness is ensured
with 5 rows of soft seal.

3 www.etna.com.tr
Details of Fire Pump Systems in NFPA 20 Standard

Back-up Pump
Manometer Electrical Panel Main Pump
Electrical Panel
Relief Valve
Delivery Collector

Expansion Tank Output

Butterfly Valve

Disco Check Valve

Rising
Stem Valve

Electrical Engine

Reduction
Suction Collector
Pilot Pump
Vacuum Meter

4
Electrically Driven
Vertical Shaft Multistage Fire Pump

Number of Main Pumps :1-3


Number of Pilot Pumps :1
Maximum Capacity - Flow Rate : 3 x 140 m3/h
Maximum Pressure : 200 mSS
Max. Electric Pump Power : 90 kW
External Control Voltage : 24 V
Panel Control Class : IP 54

Pilot
Electrically Driven
Pump Panel
Fire Pump

Number of Main Pumps :1-3


Number of Pilot Pumps :1
Maximum Capacity - Flow Rate : 3 x 500 m3/h
Maximum Pressure : 120 mSS
Max. Electric Pump Power : 200 kW
External Control Voltage : 24 V
Panel Control Class : IP 54

Electrical / Diesel
Intermediate Fire Pump
Reduction
Number of Main Electrical Pumps : 1
Number of Main Diesel Engine Pumps : 1
Number of Pilot Pumps :1
Maximum Capacity - Flow Rate : 2 x 500 m3/h
Maximum Pressure : 120 mSS
Max. Electric Pump Power : 200 kW
Max. Diesel Pump Power : 225 kW
External Control Voltage : 12 - 24 V
Panel Control Class : IP 54

5 www.etna.com.tr
Electrically Driven Pump
Protection-Control Panel

• Except for the engine, all outlet connection


are low voltage (12/24 Vdc)
• 3 Voltmeters
• 3 Ammeters (max.1000 A)
• Grid phase meter 50/60 Hz
• Phase sequence
• Wattmeter (Active power)
• Varmeter (Reactive power)
• V/A meter (Current power)
• Cosine meter (Power factor)
• Total operating time
• Partial operating time
• Automatic - Manual switch, manual start and stop
in manual mode

Diesel Driven Pump


Protection-Control Panel

• Except for the engine, all outlet connections are


low voltage (12/24 Vdc)
• 2 Batteries
• 2 Voltmeters
• 2 Battery ammeters
• Tachometer
• Temperature gauge
• Oil temperature gauge
• Oil pressure gauge
• Fuel level gauge
• 2 Battery charging rectifiers
• Battery efficiency control
• Operation error report
• Manual operation buttons
• Warning lamp test button
• Test commissioning
• Monitoring individual charging of batteries
• 3+3 = 6-cycle automatic start-up
attempt from batteries
• Automatic - Manual switch, manual start and stop
in manual mode

6
NFPA 20 Water Booster Versions

Series Description

ETNDI Diesel engine pump

Diesel engine pump and pilot


ETN01D
pump booster set +

Booster set with diesel engine pump


ETN10D
and electrical engine

Booster set with diesel engine,


ETN11D
electrical engine, and pilot pump

Series Description Horizontal pump series Vertical shaft series

Booster set with electrical engine


ETN10
pump

Booster set with electrical engine


ETN11
pump and pilot pump

Booster set with two main electrical


ETN20
pumps

Booster set with two main electrical


ETN21
engine pumps and pilot pump

Modular System

A B C
2 2

3 4 3 4
3 4

1 1 2
1

Diesel pump module A Diesel main pump module Horizontal pump module Vertical pump module
B Pilot pump module
C Electrical main pump module
6

1. Eccentric suction kit 5. Flow meter kit


2. Pressure collector 6. Back to tank
3. Pump pressure switch 7. To main unit
4. Supply tank connection
7 7
2 5

7 www.etna.com.tr
After-Sales Services
We are here for you with our more than 35 years of sector experience, 95
service points all around Turkey, and customer-oriented after-sales service
approach (commissioning, maintenance and repair, spare part supply).

Dudullu Organized Industrial Zone Street 2 No. 14


34775 Ümraniye - Istanbul / Turkey
Tel. +90 216 561 47 74 (Pbx) • Fax. +90 (216) 561 47 50
www.etna.com.tr • info@etna.com.tr customer service