Sei sulla pagina 1di 3
WinCC/industriaiDataBridge Installation Notes 1.3 Hardware and Software Prerequisites 1.3 Hardware and Software Prerequisites Hardware Requirements In order to work with IDB V7.4, you need a personal computer (PC) with at least the following features: '* 2.0 GHz Core 2 Duo processor '* 2B RAM (for 32-bit OS); 4 GB RAM (for 64-bit OS) © 5 GBon system drive "C:" ‘The hardware pre-requisites depend on the used volume of data and the number of projects/ links created, Note ‘Archiving space Itis suggested to set aside certain amount of additional space on the hard drive for storing the archived files, Note WinCC hardware requrements. WinCC V7.4 is required for working with the IndustrialDataBridge Getting Started project. For WinCC V7.4 installation requirements, please refer WinCC Installation manual Sottware Requirements IndustrialDataBridge V7.4 provides support for 32-bit operating systems as well as 64-bit operating systems ‘The following 32-bit operating systems are supported: © Windows Server 2008 Standard © Windows Server 2012 Standard © Windows Server 2008 R2 Standard © Windows Server 2012 R2 Standard © Windows 7 Professional Sp1 © Windows 7 Ultimate Spt © Windows 7 Enterprise Spt © Windows 8.1 Enterpnse Wwinccindustnaibatabciage System Manual, 8/2015, Printout ofthe Online Help 9 WinCCiindustrialDataBridge Installation Notes 1.3 Hardware and Software Prerequisites ‘The following 64-bit operating systems are supported: © Windows Server 2008 Standard © Windows Server 2012 Standard © Windows Server 2008 R2 Standard © Windows Server 2012 R2 Standard © Windows 7 Professional Sp © Windows 7 Ultimate Sp1 © Windows 7 Enterprise Sp1 © Windows 8.1 Pro WinCC is required for integration in the WinCC Explorer. The following software must already have been installed '* Microsoft intemet Explorer 6.0 (or higher) Error Messages If you use any other operating systems from the list mentioned above, the IDB installation will be aboried and an error message will be displayed. For details about the error messages, please see the table below Error Message Explanation To execute installation properly, restart the computer The software installed on your computer requres a restart Before WinCC can be installed, the computer should be re- started once. Required operating system Windows 7 Uparade the operating system to Windows 7 Required operating system Windows 2008 Uporade the operating system to Windows 2008, You do not have administrator rights. Log on as an adminis- | Administrator rights are required for installation. Please log trator, Into Windows as a user with administrator rights. 10 ‘Additional Software Additional software is required in the following instances: In IDB V7.4, to use WinCC OLEDB as Provider, one of the following product(s) need to be operational on the computer wherever IDB is installed © Wince v7.4 © ConnectivityPack Client IF this is not the case, the ConnectivityPack Client must be installed from the WinCC DVD, WinccindusiraibataBriage ‘System Manual, 8/2015, Printout of the Online Help WinCC/industriaiDataBridge Installation Notes 1.3 Hardware and Software Prerequisites In IDB V7.4, to use OPC XML as Provider or Consumer, the following prerequisites needs to be installed while using WinC OPC XML Server: ‘© WinCc OPC XML Server (using WinCC Setup) ‘* Wincc Connectivity Pack (License is required) ‘© Intemet Information Server iIIS) ‘© Microsoft NET Framework ‘© Microsoft ASP.NET ‘While using any other OPC XML Server, the prerequisites to be installed are listed below: ‘© Internet information Server iIIS) ‘© Microsoft NET Framework ‘© Microsoft ASP.NET ‘While using Send/Receive as Provider or Consumer, to be able to send or received data toor from PLC, STEP7 Professional software is required. However, this software is required only if you wish to transfer data to or from the PLC. For more information about STEP7 hardware prerequisites, refer "System Requirements STEP7 Professional" MySOl Database IFIDBis to be used with a MySQL database (V5.6 or V5.7), the following driver must be installed © MySQL Connector for ODBC V3.51 ‘The software driver is not delivered on the CD. It can be downloaded from the Intemet. ‘SQL Server For using SQL Server database (2012 / 2014) with IDB, the following driver must be installed. © MS OLE DB Provider for SQL SQL Server software (2014) is available as part of WinCC Classic V7.4 setup, Note Read and Wite Authorization ‘You need read and write access to the installation folder of the industrialDataBridge to run the configuration and runtime interface. If you create the configuration or trace files in a different folder, read and write access to the specific folder is required. Wwinccindustnaibatabciage System Manual, 8/2015, Printout ofthe Online Help "

Potrebbero piacerti anche