Metal-Enclosed Switchgear
Internal Arc-Proof
HMS Switchgear
up to 36 kV,
Medium Voltage
Air-Insulated
Metal-Enclosed Switchgear
LSC 2B, Internal Arc-Proof
CONTENTS
Description
08 Characteristics
10 Application
11 Loss of Service Continuity
12 Arc Classification
13 Test & Standard
Automation
14 Power Management System (SCADA)
15 Construction
Technical Data
18 7.2/12 kV Switchgear
24 17.5 kV Switchgear
26 24 kV Switchgear
28 36 kV Switchgear
Component
29 Switching Device
30 Instrument Transformer
31 Room Planning
HMS series, HYUNDAI Medium Voltage
Air-Insulated Metal-Enclosed Switchgear, provides various
benefits with its safe, reliable features, and compact design.
HMS series, HYUNDAI Medium Voltage
Air-Insulated Metal-Enclosed Switchgear, manufactured and tested
based on experience acquired throughout the world since 1979
Description
Characteristics
HMS series, HYUNDAI Medium Voltage Air-Insulated Metal-Enclosed Switchgear, provides the highest level
of performance and various advantages with their reliable features and compact design to meet all electrical
requirements of the medium voltage distribution system up to 36 kV.
• Relays
HMS-N12C
8 / HYUNDAI ELECTRIC
Safe and Reliable Features
• Loss of service continuity category LSC 2B
• Partition class PM
and partitions
• Internal arc classification IAC AFLR
of the switchgear
• Interlock and padlocks prevent operator
errors
• Type-tested for each switchgear type
HYUNDAI ELECTRIC /9
Description
Application
• Switching stations
≤ 17.5 kV: Up to 4,000 A
Normal current • Power generation stations
> 24 kV: Up to 3,150 A
• Main and auxiliary switchgear
≤ 12 kV: Up to 50 kA (3 sec)
= 17.5 kV: Up to 50 kA (3 sec)
Short-circuit withstand current Industry
= 24 kV: Up to 25 kA (3 sec)
• Chemical industry
> 36 kV: Up to 31.5 kA (3 sec)
• Petroleum industry
Loss of service continuity category and partition class
• Iron and steel works
Loss of service continuity category LSC2B (metal-clad) • Automobile industry
Partition class PM (metallic partition) • Oil and gas pipelines
IP41,2
For optional enclosure Available on request
IP51,2
10 / HYUNDAI ELECTRIC
Loss of Service Continuity
earthing point of the functional unit are used to cover fixed The rated normal current of the switchgears depends on the
contacts when the switching device is withdrawn to the test/ ambient air temperature outside the enclosure (please contact
disconnected position or removed position. us for details).
• Site Altitude
accessible to busbar compartment need tools to be opened. Must be agreed depending on the conditions (please
contact us for possible adaptation).
HYUNDAI ELECTRIC / 11
Description
Arc Classification
Protection Degree
Protection against entry hazardous parts and water of the HMS switchgear according to the IEC 62271-200 and IEC 60529
following degree of protection.
• Metal pressure relief positioned above the enclosure, which When installing the switchgear, some fundamental points
in the case of internal fault, limits overpressure in the must be taken into consideration:
compartments.
• Nonflammable materials used for the cubicle. • Escape routes for the hot and toxic gases given off.
• The switchgear complies with all criteria specified in the • Dimensions of the room, with special attention to the height.
• Accessibility: A, B or C
12 / HYUNDAI ELECTRIC
Test & Standard
Certified Quality System: ISO 9001 & ISO 14001 Routine Test
The quality system for the design and manufacture of HMS The HMS was designed for unsurpassed structural strength,
switchgear is certified to be in conformity with the to be arc proof, and to offer trouble-free installation and
requirements of ISO 9001 quality assurance standard from operation providing complete customer satisfaction.
DNV certification B.V., The Netherlands. To ensure the quality and conformity of each functional unit,
The environmental management system is assessed and systematic routine testing is performed after manufacturing
recognized as conforming to the requirements of the ISO as follows:
14001 standard.
• Visual inspections and checks
Type Test
The HMS switchgear are fully type tested according to
international (IEC) standards and also tested in accordance
with rules required by the major shipping registers (LR,
DNV GL, RINA and BV) for use of the switchgear in marine
installations. As described in the IEC, the tests were made
on representative functional units considered most sensitive
to the effect of the tests.
Standard
IEC 62271-1
Switchgear HMS
IEC 62271-200
Circuit-breaker IEC 62271-100
Vacuum contactors IEC 62271-106
Disconnector and
Device IEC 62271-102
earthing switch
Switch IEC 62271-103
HV HRC fuse IEC 60282
Degree of protection IEC 60529
Insulation IEC 60071
Insulation Current transformer IEC 60044-1
transformer Voltage transformer IEC 60044-2
HYUNDAI ELECTRIC / 13
Automation
HiPAS, HYUNDAI Intelligent Power Automation System is a power management system which consists of independent
function modules in a network. It can be divided into 3 system levels; “Master”, “PCM”, and “Device”.
system’s mode, either ESM or OSM. There are 4 kinds of • Remote setting of the communicating IEDs (HiMAP)
It is a kind of FEP. PCM executes the various algorithm on • Monitoring of system network status
the basis of real time value gathered from “Field”. HYUNDAI • Report management
product name at PCM level is “HICM-860S”. • Security access within the login/logoff procedure
Other System
GPS INTERNET
ETHERNET
HICM860S (P) HICM860S (S) S/W HUB S/W HUB HICM860S (P) HICM860S (S) HICM860S (P) HICM860S (S) HICM860S (P) HICM860S (S)
Notebook PC
14 / HYUNDAI ELECTRIC
Construction
The HMS switchgear was designed for unsurpassed structural strength, to be arc proof, and to offer trouble-
free installation and operation providing complete customer satisfaction. Influence due to internal arc faults is
minimized by pressure relief ( E ) which is located on each functional compartment.
Internal arc fault test was performed with the classification IAC AFLR, arc duration of 1 s for up to 50 kA according
to individual type of switchgear.
Vacuum circuit breakers and vacuum contactors which are used for main switching device have been proven to be
desirable by their improved reliability, longer maintenance free life cycle, eco-friendly design and compact size.
The operations of main switching device is possible with high-voltage door closed. Cable connection compartment
can be accessible from front in case front accessible type (Fig.4) or from rear side in case rear accessible type (Fig.5).
Assembly Finish
Each panel consists of three power compartments: The switchgear enclosure is cleaned and rust-proofed which
main switching device compartment ( A ), busbar is made of zinc galvanized steel sheet. The doors and end
compartment ( B ) and cable connection compartment ( C ). cover plates are painted through HYUNDAI standard
Each panel is fitted with a low voltage compartment ( D ), electrostatic powder coating procedure.
where all the instruments and cabling are housed. RAL7035 is normally used for the finishing color if customer
The compartments are segregated from each other by does not specify other colours.
metallic partitions.
Arc-proof switchgear is normally provided with a pressure
relief ( E ) and/or arc duct ( F ) for the reliving of pressure and
evacuation of the gases which may be induced by arc.
E B
E F
D
D
A C
Fig.4 Section view for front accessible type (HMS-N12C) Fig.5 Section view for rear accessible type (HMS-N12)
HYUNDAI ELECTRIC / 15
Construction
Main Switching Device Compartment Fig.6 Main switching device & LV compartment
• HYUNDAI HVF type vacuum circuit breakers which are used
cycle, and compact size. of internal arcs in the panel, and the high-voltage door can
• The fixed contacts of the primary part are encapsulated by withstand the pressure safely.
the primary bushing. • Position of circuit breaker, earthing switch and low-
• The metal shutters which are earthed, automatically cover voltage plug connector for connection of control cables are
the fixed contacts of both line and load side when the interlocked according to the requirements of IEC 62271-200
switching device is moving to the test/disconnected position. and customer’s specification.
Fig.7 Main switching device compartment with circuit breaker Fig.8 Main switching device compartment without circuit breaker
16 / HYUNDAI ELECTRIC
Busbar Compartment Interlocks
• The main busbars are • The withdrawal or engagement of switching device is
• The main busbars are prevented unless earthing switch is in the open position.
vertically connected to the • Earthing switch can only be operated with switching device
• Top or bottom entry for both bus ducts and power cables
Fig.10 Removal voltage transformer in cable compartment Fig.11 HES type earthing switch
HYUNDAI ELECTRIC / 17
Technical Data
7.2/12 kV Switchgear
HMS-112
IF BT BR OF
112H MV SWGR
ES
VCB VCB VCS
VCB
ES ES
VT
CT
CT
VT
H
1)
W D
18 / HYUNDAI ELECTRIC
HMS-N7.2
IF BT BR OF
VCB
ES
CT
ES
ES
CT
CT
VT VT VT VT
H
IF (VT) IF (VCB) OF
HYUNDAI ELECTRIC / 19
Technical Data
7.2/12 kV Switchgear
HMS-N12C
IF BT BR OF
VCB
VT(REMOVABLE)
CT
CT
GL RL
CS
CT
ES
ES
H1
ES
H
VT VT VT VT
1)
W D
※ 1) Connection compartment can be accessed from the front, but rear side accessible panel available on request.
2) Current values and short circuit breaking current of contactor panel dependent on HV HRC fuses.
3) The size of actual panel can be different according to the rating, quantity, and arrangement of components.
4) Extend panel is available for installing a ZCT in the switchgear, more than one CT per phase or some more equipment than our standard on request.
5) Extend LV compartment is available according to the kind and quantity of components in the LV compartments.
20 / HYUNDAI ELECTRIC
HMS-N12
IF BT BR OF
VCB
ES
CT
ES
ES
CT
CT
VT VT VT VT
H
IF (VT) IF (VCB) OF
HYUNDAI ELECTRIC / 21
Technical Data
7.2/12 kV Switchgear
HMS-N7.2D
OF VT VT OF
1)
H
OF OF IF BT BR IF OF OF
1)
W D
22 / HYUNDAI ELECTRIC
HMS-N12D
OF VT VT OF
H
1) OF OF IF BT BR IF OF OF
1)
W D
HYUNDAI ELECTRIC / 23
Technical Data
17.5 kV Switchgear
HMS-N17.5C
IF BT BR OF
VCB VCB
VT(WITHDRAWABLE)
VCB
VT(REMOVABLE)
CT
CT
CT
ES
ES
H1
ES
H
VT VT VT VT
1)
W D
※ 1) Connection compartment can be accessed from the front, but rear side accessible panel available on request.
2) The size of actual panel can be different according to the rating, quantity and arrangement of components.
3) Extend panel is available for installing a ZCT in the switchgear, more than one CT per phase or some more equipment on request.
4) Extend LV compartment is available according to the kind and quantity of components in the LV compartments.
24 / HYUNDAI ELECTRIC
HMS-N17.5
IF BT BR OF
VCB VCB
VCB
ES
CT
ES
ES
CT
CT
VT VT VT
H
1), 2)
INCOMING FEEDER BUS TIE BUS RISER OUTGOING FEEDEDR
IF (VT) IF (VCB) OF
VCB VCB
VT
W D ES
CT
ES
CT
HYUNDAI ELECTRIC / 25
Technical Data
24 kV Switchgear
HMS-N24
IF BT BR OF
VCB VCB
VCB
ES ES
CT CT
CT
H
VT VT
LBS VT MOF
1)
LA
PF
LBS
VT
MOF
W D ES
※ 1) Connection compartment can be accessed from the rear, but front side accessible panel available on request.
2) The size of actual panel can be different according to the rating, type, quantity, and arrangement of components.
3) Extend panel can be used when installing a ZCT in the switchgear or more equipment than our standard is required.
26 / HYUNDAI ELECTRIC
HMS-N108
IF BT BR OF
VCB VCB
VCB
ES ES
CT CT
CT
H
VT VT
ES
HYUNDAI ELECTRIC / 27
Technical Data
36 kV Switchgear
HMS-N36
IF BT BR OF
CT CT
VCB VCB
VCB
H
CT CT
ES ES
VT VT
1)
W D
28 / HYUNDAI ELECTRIC
Component
Switching Device
Ratings
Rated voltage 7.2 kV…36 kV
≤17.5 kV: Up to 4,000 A
Normal current
24/36 kV: Up to 3,150 A
Frequency 50/60 Hz
Short circuit breaking current ≤17.5 kV: Up to 50 kA
Short time withstand current, 3 s ≤17.5 kV: Up to 50 kA
Classification
Frequency of mechanical operation M2
Restrike performance during capacitive current switching E2
Electrical endurance without auto-recloser C2
Operating and control voltage
O-0.3S-CO-3M-CO,
Operating sequence
CO-15S-CO
Vacuum Contactor
HYUNDAI HCA and UVC vacuum contactors are designed and manufactured for frequent switchings, especially taking into
account safety and quality assurance. The contactor conforms with IEC 60470, and is suitable for switching and controlling
squirrel cage and slipring motors, medium voltage loads and resistance furnances, and capacitors and transformers.
Ratings
Rated operational voltage 6.6/11 kV
Normal current Up to 400 A
Frequency 50/60 Hz
Short time withstand current, 1 s 6.3 kA
Breaking capacity 4 kA (O-3m-CO-3m-CO)
Utilization category 6.6 kV: AC3/11 kV: AC4
Continuously energized/
Operating method
Latched
HYUNDAI ELECTRIC / 29
Component
Instrument Transformer
VT truck with fuse Single pole VT with fuse- HDPE type VT without fuse- HDPE type
30 / HYUNDAI ELECTRIC
Room Planning
Plan View for Front Accessible Panel Plan View for Rear Accessible Panel
B A
B A
D
D
30 30
30 30
C
C
Panel type A B C D
Front HMS-N12C
1,700 200 150 150
accessible panel HMS-N17.5C
HMS-N12
HMS-N17.5
HMS-N12D
HYUNDAI ELECTRIC / 31
HE-SE-B39-05, 2018.9 Designed by designwat
KOREA
Headquarter Hyundai Bldg, 75, Yulgok-ro, Jongno-gu, Seoul, Korea
(Financial) Tel: +82-2-746-7646 / Fax: +82-2-746-7441
Sales & Marketing 5th Floor 55, Bundang-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea
(Seongnam) Tel: +82-31-8006-6635 / Fax: +82-31-8006-6629
Main Factory 700, Bangeojinsunhwan-doro, Dong-gu, Ulsan, Korea
(Ulsan) Tel: +82-52-202-8114 / Fax: +82-52-202-8010
Seonam Factory 223, Sapyong-ro, Nam-gu, Ulsan, Korea
(Ulsan) Tel: +82-52-202-8114
R&D Center 17-10, 240-gil, Mabuk-ro, Giheung-gu, Yongin-si, Korea
(Yongin) Tel: +82-31-289-5114 / Fax: +82-31-289-5040
OVERSEAS
Branch Offices
Subsidiaries
R&D Centers
Hungary Hyundai Technologies Center Hungary ltd., 1146, Budapest, Hermina ut 22, Hungary
(Budapest) Tel: +36-1-273-3733 / Fax: +36-1-220-6708
China Room 10102, Building 10, No.498, Guoshoujing Road, Pudong, Shanghai, China
(Shanghai) Tel: +86-21-5013-3393 #108 / Fax: +86-21-5013-3393 #105
Switzerland Hardturmstrasse 135, CH-8005, Zurich, Switzerland
(Zurich) Tel: +41-44-527-0-56
www.hyundai-electric.com