Sei sulla pagina 1di 2

Slab Design (2nd floor slabs)

𝐿
ℎ= = 208.33 ~ 220 𝑚𝑚
24
169.41
𝑀𝑛 = = 188.23𝑘𝑁𝑚
0.9
0.85𝑓𝑐 ′ 2𝑅𝑛 188.23(10002 )
𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = (1 − √1 − ) ; 𝑅𝑛 = = 5.3541
𝑓𝑦 0.85𝑓𝑐 ′ 25 2
(1000) (220 − 20 − )
2
𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 0.01464
𝜌𝑚𝑖𝑛 = 0.00333
0.85𝑓𝑐 ′ 600
𝜌𝑚𝑎𝑥 = 0.75 [( ) (𝛽1 ) ( )]
𝑓𝑦 600 + 𝑓𝑦
𝜌𝑚𝑎𝑥 = 0.02125
USE 𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑
25
𝐴𝑠𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 𝑏𝑑 = (0.01464)(1000) (220 − 20 − )
2
𝐴𝑠𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 2744.7460𝑚𝑚2
𝑭𝒐𝒓 𝑴𝒂𝒊𝒏 𝑹𝒆𝒊𝒏𝒇𝒐𝒓𝒄𝒆𝒎𝒆𝒏𝒕
2744.7460
𝑛𝑏𝑎𝑟𝑠 = 𝜋 = 5.6187
(25)2
4
𝑛𝑏𝑎𝑟𝑠 ~ 𝟔 𝒃𝒂𝒓𝒔
1000 − 6(25)
𝑠=
5
𝑠 = 𝟏𝟕𝟎𝒎𝒎
𝑭𝒐𝒓 𝑻𝒆𝒎𝒑 𝑩𝒂𝒓𝒔
𝑓𝑦 = 420𝑀𝑃𝑎 ; 𝜌 = 0.0018
10
𝐷𝑡 = 220 − 20 − 25 −
2
𝐷𝑡 = 170𝑚𝑚
𝐴𝑠𝑡𝑒𝑚𝑝 = 𝜌𝑏𝐷𝑡 = (0.0018)(1000)(170)
𝐴𝑠𝑡𝑒𝑚𝑝 = 306𝑚𝑚2
306
𝑛𝑏𝑎𝑟𝑠 = 𝜋 = 3.896
(10)2
4
𝑛𝑏𝑎𝑟𝑠 ~ 𝟒 𝒃𝒂𝒓𝒔
1000 − 4(10)
𝑠=
3
𝑠 = 𝟑𝟐𝟎𝒎𝒎
Slab Design (Roof Deck)

𝐿
ℎ= = 208.33 ~ 220 𝑚𝑚
24
75.41
𝑀𝑛 = = 83.7889𝑘𝑁𝑚
0.9
0.85𝑓𝑐 ′ 2𝑅𝑛 83.7889(10002 )
𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = (1 − √1 − ) ; 𝑅𝑛 = = 2.2729
𝑓𝑦 0.85𝑓𝑐 ′ 16 2
(1000) (220 − 20 − )
2
𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 0.005698
𝜌𝑚𝑖𝑛 = 0.00333
0.85𝑓𝑐 ′ 600
𝜌𝑚𝑎𝑥 = 0.75 [( ) (𝛽1 ) ( )]
𝑓𝑦 600 + 𝑓𝑦
𝜌𝑚𝑎𝑥 = 0.02125
USE 𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑
16
𝐴𝑠𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 𝜌𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 𝑏𝑑 = (0.005698)(1000) (220 − 20 − )
2
𝐴𝑠𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 1094.0562𝑚𝑚2
𝑭𝒐𝒓 𝑴𝒂𝒊𝒏 𝑹𝒆𝒊𝒏𝒇𝒐𝒓𝒄𝒆𝒎𝒆𝒏𝒕
1094.0562
𝑛𝑏𝑎𝑟𝑠 = 𝜋 = 5.44
(16)2
4
𝑛𝑏𝑎𝑟𝑠 ~ 𝟔 𝒃𝒂𝒓𝒔
1000 − 6(16)
𝑠= = 180.8𝑚𝑚
5
𝑠 ~ 𝟏𝟖𝟎𝒎𝒎
𝑭𝒐𝒓 𝑻𝒆𝒎𝒑 𝑩𝒂𝒓𝒔
𝑓𝑦 = 420𝑀𝑃𝑎 ; 𝜌 = 0.0018
10
𝐷𝑡 = 220 − 20 − 16 −
2
𝐷𝑡 = 179𝑚𝑚
𝐴𝑠𝑡𝑒𝑚𝑝 = 𝜌𝑏𝐷𝑡 = (0.0018)(1000)(179)
𝐴𝑠𝑡𝑒𝑚𝑝 = 322.2𝑚𝑚2
322.2
𝑛𝑏𝑎𝑟𝑠 = 𝜋 = 4.10
(10)2
4
𝑛𝑏𝑎𝑟𝑠 ~ 𝟓 𝒃𝒂𝒓𝒔
1000 − 5(10)
𝑠= = 237.5𝑚𝑚
4
𝑠 ~ 𝟐𝟑𝟎𝒎𝒎