Sei sulla pagina 1di 8

Steel Materials Page 1 of 8

A Beginner's Guide to the Steel Construction Manual

Chapter 2 - Materials
© 2006, 2008 T. Bartlett Quimby

Steel Materials
Section 2.1
Welding
Materials Steel Materials
Bolts Last Revised: 11/19/2008

References It is assumed that you have an understanding of basic steel stress-strain behavior and the nature and purpose of
American Standards for Testing Materials (ASTM) standards from the pre-requisite courses.

There are a variety of structural steels available. As we saw during the overview in section 1.3, there are also a variety
Report Errors of available shapes. As it turns out, not all shapes are readily available in all types of steel. In section 1.3 you were
or Make introduced to SCM Table 2-3. You should turn to that table now.
Suggestions
Table 2-3 relates the available ASTM steel designations to the available shapes. The black shaded boxes indicate the
Purchase Hard preferred specification/shape combination. The grey shaded boxes indicate that you can probably get the indicated
Copy specification/shape combination. If the box is white, then the shape is not available in that material.
Make
Donation The selection of ASTM specification may be driven by special project requirements. For example, the preferred
alternatives are probably the best choice for steel that is to be protected inside a building envelope. In a case where
steel will be exposed to the elements or in some other more corrosive environment, you may chose to use another
steel such ASTM A588. You might also chose to use a different type of steel where high strength will reduce the steel
demand on the project.

It should also be noted that the list of available steel changes from time to time. For example, in the early to mid
1900s the only steel specification was ASTM A6 steel (which is no longer on the list!). Later other steels were
developed including ASTM A36 and ASTM A572 which were dominate in the building structure arena. Around the year

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 2 of 8

2000, ASTM A992 steel was introduced which economically meets the requirements of both ASTM A36 and ASTM
A572. ASTM A992 is now the dominate steel specification for several shapes. Knowing something of the history will
allow you to evaluate buildings that were constructed before the current specifications were made available.

A Note about Symbols

Before getting into the actual material properties it is useful to note at the SCM has traditionally used the symbol "F" or
"f" to denote stresses. Most mechanics courses use the symbol sigma, σ, to denote stress.

Capital "F" is used for stress related material properties derived from a stress-strain curve. The typical values are the
specified minimum yield stress (Fy) or the specified minimum tensile strength (Fu). Whenever you see the capital "F"
you know that you are looking at a material constant.

In the case of the ASTM requirements, the word "specified" is used to denote the required stress level. Note that the
actual yield stress and tensile strength for a given piece of steel may exceed the minimum requirements. For example
it was common for A36 steel (with Fy = 36 ksi) to have actual yield stresses of 40 ksi or more. For design purposes,
however, minimum specified values are always used since the actual values for the particular piece of steel to be used
for a particular member is rarely known.

For denoting computed stresses, the lower case "f" is used. For example, fb is the computed bending stress (M/S), fa
is computed axial stress (P/A), and fv is the computed shear stress (VQ/Ib).

Primary Steel Properties

For the purposes of the Specification for Structural Steel Buildings, four quantities are particularly important for a given
steel type: the minimum yield stress (Fy), the specified minimum tensile strength (Fu), the Modulus of Elasticity (E)
and the Shear Modulus (G). Some of these values are shown below on a typical stress-strain curve from a tension test
in Figure 2.1.1. These quantities appear in the limit state equations found in the specification. Other properties such
as the Poisson's ratio, coefficient of thermal expansion and ductility are also important considerations in analysis and
design.

Figure 2.1.1

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 3 of 8

Typical Stress-Strain Curve

Modulus of Elasticity, E

The Modulus of Elasticity (E) is a measure of a material's axial stiffness. Stiffness and strength are not the same
thing. As it turns out, the value for the modulus of elasticity (E) is the same for all steel types. There is no difference
in stiffness with type of steel. The value used by the SCM is 29,000 ksi. (See SCM pg 16.1-xxx, the symbols section.)

Shear Modulus, G

The shear modulus, G, is a measure of the shear stiffness of the material. It is a constant for all steels and has the
value of 11,200 ksi (see SCM pg 16.1-xxxii).

The fact that all steels have the same E and G means that for members whose design is controlled by a stiffness limit
states (i.e. deflection or vibration), the type of steel used is unimportant. In these cases, there is no advantage to

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 4 of 8

using a higher strength steel over one with lower strength. You will particularly notice this in long span beams where
deflection becomes the controlling limit state.

Minimum Specified Yield Stress, Fy

The minimum specified yield stress, Fy, is just that: the MINIMUM specified yield stress. It can be, and often is,
higher than specified as previously stated. The ASTM specifications only require that the yield stress be at least the
specified value. Even though it is likely to be higher than specified, unless you have tests verifying the actual yield
stress for your steel, you can only use the minimum ASTM specified value in the calculations.

The values for Fy (and for Fu) are listed in SCM Table 2-3. You will note that some times there is a range of values
listed. In this case, you should use the lower value of the range in your computations unless you have a good reason
to do otherwise and can be assured that the steel used in the project meets the higher value.

Minimum Specified Tensile Strength, Fu

The minimum specified tensile strength, Fu, is often referred to as the ultimate strength of the material. It is the
largest value of stress that the material will support. This value is commonly used to determine the maximum or
nominal strength of a member.

As noted above, Fu can also be found in SCM Table 2-3.

Note that all steels have the same stiffness, E, but not the same strength, Fy and/or Fu. Using high strength steel is
only an advantage if the limiting criteria are strength related instead of stiffness related.

General Steel Properties

In addition to the four basic properties of steel there a number of other properties that you will need to know about.

Poisson's Ratio, ν

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 5 of 8

Poisson's ratio is often use in structural analysis but does not find it's way into the strength and serviceability equations
of the SCM. The value of n typically used for steel is 0.03.

Coefficient of Thermal Expansion, ε

The coefficient of thermal expansion, ε, is necessary in computing deformations and forces in structures as a result of
changes in temperature. It does not show up in the strength and serviceability limit state equations found in the
SCM. While most building frameworks are kept at nearly constant temperature inside a building envelope, there are
still many cases where steel structures are subject to widely ranging temperature values and, as a result, see
significant deformation which, in turn, can result in large forces within the members.

Table 17-11 (see SCM page 17-23) lists the coefficients of thermal expansion for a number of materials, including
steel. For mild steel the value of ε is .0000065 in/in/deg F.

Other Things to Know When Using Steel

Part 2 of the SCM covers a number of topics that you need to be knowledgeable about when you use steel as a
structural material. We will point out a few here. You need to read the relevant sections of Part 2 to gain a basic
understanding. Follow up with many of the references given in Part 2 will give you detailed information about each
item.

Tolerances

Tolerance is the allowed departure from a specified dimension. How much deviation can be "tolerated". It is
important to realize that as-built dimensions may vary a little from those dimensions placed on the design drawings.
Exact dimensions are hard to come by in the milling, fabrication, and erection processes. This is recognized by the
profession. Standards for allowable deviations are stated in a number of ASTM specifications and in the AISC
specification. In most cases, tolerances are not a major issue in the building design process, but can be in special
situations.

One special case is the interface of the supporting structure with architectural features such as curtain walls. Building
facades are frequently very susceptible to tolerance issues. Take the time to ready the SCM section (pg 2-17) on this
topic. Building deflections and thermal expansion may cause distress to supported features. Details that allow for

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 6 of 8

differential movement must be devised when this is the case. In this introductory text such details will not be
considered, however it is an excellent topic for a more advanced course in structural steel design.

Camber, Sweep and Straightening

The SCM section on this topic is also very good. It is very common to intentionally bend steel members to compensate
for dead load deflections or to fit curved architectural features. Knowing what you can and cannot do with pre-
bending or straightening steel members is important when laying out framing systems for buildings and other
structures.

Fire Protection and Engineering

One of the major weaknesses of steel as a structural material is its susceptibility to fire induced loss of strength as well
as a change in material properties after heating and cooling. The SCM refers you to the AISC Design Guide 19, Fire
Resistance of Structural Steel Framing. Fire behavior is an extensive topic that needs to be considered when designing
steel buildings. In this first steel design course however, we will not be spending any time on the topic as we will have
our hands full learning the strength and serviceability requirements of the AISC specification. Just be aware that a
steel structure essentially loses all its strength in a normal building fire situation. Fire safety techniques focus on
slowing down the heating process so that occupants can safely exit the building during a fire event. A dramatic
example of the effect of fire on steel was the collapse of the twin towers in New York after the terrorist attacks on that
city. The collapse was largely the result of the core supporting structure losing its strength during the fire that
followed the plane crashes.

Cold Weather Effects

The SCM is fairly quiet on the subject of cold weather effects on steel. There is a paragraph on pg 2-34 that
introduces the subject. In most building frames cold weather is not an issue since the frames are encased in a heated
building envelope. However, an understanding of the effect of cold on steel is important anywhere the steel will be
exposed to cold temperatures. This may occur in a refrigerated facility or in exterior structures in cold regions.

The general effect of cold on steel is to cause a reduction in ductility. A slight increase in the strength parameters
occurs and stiffness is unaffected. These changes start to occur as the steel temperature drops below 40 degrees F
are very pronounced when temperatures approach 10 degrees F.

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 7 of 8

The ductility issue is extremely important. In buildings and other civil engineering structures, local stress
concentrations are not normally considered since ductility will allow local yielding to redistribute the stresses. For
situations where local stress concentrations are common, the AISC specification tends to use a low reduction factor, φ,
in LRFD and a larger factor of safety, Ω, for ASD. These are not sufficient when ductility is substantially reduced.

Failure of cold steel tends to be brittle, which means that it generally happens suddenly and without notice. Fractures
tend to originate at locations of high stress concentration and propagate rapidly through the member. This behavior is
very undesirable.

Approaches for dealing with this problem involve using steel with a formulation that is less susceptible to cold
embrittlement or by severely reducing the computed capacity of the members. The AISC specification does not
account for cold weather behavior. Large organizations that regularly have exposed steel structures in cold
environments often develop their own criteria for determining member capacity when exposed to cold.

For example one company with a large inventory of exposed structures in the arctic has developed an allowable stress
design specification that essentially reduces all allowable stress to 25% of what they would be in warm conditions.
This is on the assumption that the stress concentration factors for structures designed to their specification (which
includes detailing requirements) will rarely exceed 4.0. The result of the specification is that steel is treated as a non-
ductile material. The resulting structures tend to be much heavier than would be found in more temperate climates.

Corrosion Protection

Another problem with steel as a structural material is it susceptibility to corrosion. The SCM discussion on this topic is
a good introduction to the topic. You should read this section.

Fatigue and Fracture Control

As a crystalline material, steel is very susceptible to brittle fracture due to fatigue. There are other mechanisms that
lead to brittle fracture as well. The SCM discussion on pg 2-33 is a must read section for engineers designing in steel.

Wind and Seismic Design

Both wind and seismic events have very high strain rates which can lead to brittle behavior. In addition, current

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010
Steel Materials Page 8 of 8

practices in seismic design typically do not design structures to resist forces elastically. There is an inherent
dependence on material ductility in the design philosophies for wind and seismic conditions. Special detailing is
required to ensure ductile behavior of steel structures in these events. There have been significant advancements in
this area in recent years. These detailing requirements, again, are topics for a more advanced course, however, you
should take the time to read the SCM discussion on pg 2-35.

<<< BGSCM Table of Contents<<< >>> Next Section >>>

http://www.bgstructuralengineering.com/BGSCM/BGSCM002/index.htm 12/2/2010