Sei sulla pagina 1di 3

DEMO PLAN LEGEND DEMOLITION PLAN LEGEND

EXISTING REINFORCED CONCRETE COL.


03 REMOVE ALL EXISTING FLOORING AND BASE FINISHES, 01 COMPLETELY GUT OUT THIS AREA. DEMOLITION SHALL OR CONCRETE WALL TO REMAIN
06 REMOVE ALL EXISTING PLUMBING FIXTURE, 04 COMPLETELY REMOVE EXISTING PARTITIONS
INCLUDING BUT NOT LIMITED TO THE FOLLOWING: CONSIST OF LEAVING ENTIRE AREA FREE AND CLEAR
COORDINATE WITH PLUMBING DEMOLITION DRAWINGS EXISTING WALL OR PARTITION
- VINYL COMPOSITION TILE, VINYL RUBBER BASES. OF ANY PARTITION, HANDRAILS,CORNER
05 REMOVE ALL EXISTING ACOUSTICAL CEILING TILE, TO REMAIN
07 REMOVE SINGLE FACE OF GYPSUM WALLBOARD, - CERAMIC, CERAMIC MOSAIC TILE, PORCELAIN, MARBLE GUARDS,FINISHES,CEILINGS, PLUMBING AND LIGHT
GYPSUM BOARD AND/OR PLASTER CEILINGS,
REMOVE FURRING AND INSULATION AND REPLACE AS AND BASES. FIXTURES,DOORS, FLOOR FINISHES ETC. UNLESS
INCLUDING SOFFITS, SUSPENSION SYSTEM, CUBICLE
PER WALL TYPE.(TYPICAL EXT. WALL) - CARPET WITH RUBBER/WOOD BASES. OTHERWISE NOTED THE SPACE SHALL BE LEFT READY WALL OR PARTITION WITH
CURTAINS / TRACKS, ETC. AS GENERALLY INDICATED
- INCLUDED WITH ALL OF THE ABOVE, REMOVE TO CONSTRUCT A NEW INTERIOR SPACE AS SHOWN IN EXISTING DOOR TO REMAIN
BY DOTTED LINES INCLUDING PLASTER AND/OR
08 REMOVE EXISTING CONCRETE PADS. ADHESIVE, SETTING BEDS AND/OR GROUT, AS THE NEW FLOOR PLAN DRAWINGS.
GYPSUM WALLBOARD AND METAL FURRING STRIPS
AROUND COLUMNS. COORDINATE ALL REMOVAL WITH REQUIRED TO RECEIVE NEW SCHEDULED FINISHES.
02 REMOVE EXISTING DOOR / FRAME
MECHANICAL, ELECTRICAL AND PLUMBING ITEMS EXISTING WALL OR PARTITION
(INCLUDING LIGHTING FIXTURES, REGISTERS, GRILLES, LEAVE SLAB READY TO ACCEPT NEW SCHEDULED
TO BE REMOVED
ETC.) REFER TO M.E.P. - FP DOCUMENTS. FINISH. GRIND CONCRETE SLAB AS REQUIRED TO LEAVE 3081 Salzedo Street, Third Floor
A LEVEL SURFACE. Coral Gables, FL 33134
WALL OR PARTITION WITH T 305 444 0413
EXISTING DOOR TO BE REMOVED www.mgearchitects.com
AA-F000121

DENOTES AREA OF DEMOLITION.


COORDINATE WITH SYMBOLS
AND DEMOLITION NOTES CONSULTANTS:

MEP
1i DEMOLITION SYMBOL
TLC Engineering for Architecture
(SEE DEMOLITION LEGEND)
255 South Orange Avenue
F H J K L M N AP Orlando, FL 32801 T 407.841.9050
1.1 FL Registration Number: EB0000015

STRUCTURAL ENGINEERS

A Bliss & Nyitray, Inc.


800 Douglas Road, Suite 300
Coral Gables, FL 33134 T 305.442.7086
12P REMOVE RAILING
FL Registration Number: EB00000674

FOR NEW STAIR -


SEE PLAN

REMOVE CURB

1.8.1
B UP DN
2.1 14P
1 1
PROJECT NAME:

REMOVE ALL
FIXTURES AND
FINISHES

2.8.1 15P Baptist Health South


Florida
3.1

PORTION OF FLOOR
Orthopedic Center
TO BE REMOVED - Interior Renovations
SEE STRUCT
Design Development
2 2
UP
REMOVE EXIST CONC. JOB NO: 2015.038
WALL - COORD. W/ STRUCT. DATE: 04-14-2016
DN AGENCY NUMBER: Checker

16P REVISIONS/SUBMISSIONS :

4.1 EXISTING ELEVATOR


EXISTING SHAFT & DOORS TO BE
UP REMOVED
SPACE TO REMAIN,
SHAFT WALLS TO
RECEIVE NEW FINISH REMOVE EXIST CONC.
WALL - COORD. W/ STRUCT.
A UP

3
3
EXISTING STAIR
TO BE REMOVED

REMOVE BOLLARDS

17P

SEAL :
B

4 4
18P

JOSE L. ESTEVEZ, AIA AR-0008463


ROLANDO CONESA, AIA AR-0011748
ROBERTO A. SMITH, AIA AR-0010466

D E F G H J K L M N AP DRAWING TITLE:

DEMOLITION PLAN -
4/4/2016 10:00:08 AM

LEVEL 2
1 LEVEL 2 DEMO
A2.20 1/8" = 1'-0"

DRAWING NO: A2.20


EQUIPMENT PLAN LEGEND FLOOR PLAN LEGEND
WALL OR PARTITION WITH MEDICAL GAS C.R.T. 18" A.F.F. W/ PLASTIC LINED GROMMET WITHIN CABINET EQUIPMENT IDENTIFICATION SYMBOL W/SCHEDULED EQUIPMENT
WALL OR PARTITION WITH CORNER GUARD (TYP. OUTLETS ABBREVIATIONS ARE AS FOLLOWS: NU-23 ONE HOUR RATED WALL
1. MECHANICAL, PLUMBING AND ELECTRICAL ITEMS ARE SHOWN FOR ROOM LOCATION ONLY. REFER TO ENGINEERING DRAWINGS FOR CONSTRUCTION U.O.N.) (SEE AHCA DETAILS)
V O A N NO H O KNEE SPACE NUMBER (SEE EQUIPMENT SCHEDULE)
OR PARTITION
2 2
SPECIFICATIONS. V = VACUUM N = NITROGEN
O= OXYGEN 2NO = NITRO OXYDE DICTATION EQUIPMENT OUTLET 18" A.F.F. W/ PLASTIC LINED ACCESSORY IDENTIFICATION SYMBOL W/SCHEDULED (SEE PARTITION TYPES)
2. ROOM ACCESSORIES ARE SHOWN FOR THE PURPOSE OF CONTRACTOR ORDERING. REFER TO ACCESSORIES LEGEND, INTERIOR AND / OR A= AIR
D GROMMET WITHIN CABINET KNEE SPACE
A-23
ACCESSORY NUMBER (SEE ACCESSORY LEGEND)
WALL OR PARTITION WITH CORNER GUARD (TYP. 2 H O= WATER
CASEWORK ELEVATIONS FOR EXACT LOCATION. TWO HOUR RATED WALL
U.O.N.) (SEE AHCA DETAILS) 1
3. FURNITURE SHOWN DOTTED AND NOT LABELED WITH THE EQUIPMENT SYMBOL ARE NOT PART OF THE CONTRACT (EXCLUDING MILLWORK) AND IS KP KEY PAD (POWER OPERATED DOOR)
FAX OUTLET 18" A.F.F. W/ PLASTIC LINED GROMMET WITHIN
OR PARTITION
CABINET KNEE SPACE
SHOWN ONLY FOR THE COORDINATION OF ITEMS TO BE INSTALLED. FURNITURE LAYOUT IS GENERAL AND NOT NECESSARILY PERMANENT. CASEWORK / INTERIOR ELEVATION SYMBOL W/ ELEVATION (SEE PARTITION TYPES)
FURNITURE VENDOR IS TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO TO FABRICATION AND INSTALLATION OF FURNITURE. WALL OR PARTITION WITH BUMPER GUARD (TYP. 4 A7.01 2 NUMBER AND SHEET NUMBER (SEE ELEVATION DRAWINGS)
U.O.N.) (SEE AHCA DETAILS) PUSH PLATE (POWER OPERATED DOOR) TELEVISION CONTROL (SEE ELECTRICAL AND TELEVISION
4. AUTOMATIC DOORS AS INDICATED IN PLANS ARE SHOWN TO IDENTIFY THE LOCATION OF PUSH PLATES, OPERATORS AND OTHER ACCESSORIES. PP
VENDOR DRAWINGS)
REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. 3 LEAD LINED WALL
5. DIMENSIONS SHOWN ON EQUIPMENT PLANS ARE FOR THE PURPOSE OF EQUIPMENT LOCATION. COORDINATE EQUIPMENT PLAN DIMENSIONS WITH SINGLE PATIENT STATION (SEE ELECT. AND
DIMENSIONED FLOOR PLANS AND NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND PRIOR TO THE COMMENCEMENT OF WORK. SP COMMUNICATIONS SYSTEM VENDOR DRWGS.) PUBLIC TELEPHONE OUTLET (HC.) DENOTES HANDICAPPED TELEPHONE OUTLET
6. ALL MECHANICAL DUCTWORK/ELECTRICAL CONDUITS/PLUMBING PENETRATIONS THROUGH SMOKE/FIRE PARTITIONS SHALL BE SEALED WITH NEW WALL
LAVORATORY STATION, PULL CORD (SEE ELECTRICAL AND I TELEPHONE OUTLET
SEALANT AND/OR BLOW PATCHES AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE PARTITION AS PER PARTITION TYPE DETAILS. EP COMMUNICATIONS SYSTEM VENDOR DRAWINGS) C INTERCOM (SEE ELECTRICAL DRAWINGS) W
(WALL MOUNTED) (SEE FLOOR PLANS AND 3081 Salzedo Street, Third Floor
7. SEE EQUIPMENT SCHEDULE SHEET FOR SPECIFIC EQUIPMENT NOTES NOT ADDRESSED IN THIS DRAWING. PARTITION TYPE DETAILS) Coral Gables, FL 33134
8. ALL EQUIPMENT SHALL BE COORDINATED WITH MANUFACTURERS SPECIFICATIONS PRIOR TO INSTALLATION. NOTIFY THE ARCHITECT IF ANY EMERGENCY STATION PUSH BUTTON (SEE ELECTRICAL AND MASTER STATION (SEE ELECTRICAL AND COMMUNICATIONS W TELEPHONE OUTLET T 305 444 0413
E NM
DISCREPANCIES ARE FOUND. COMMUNICATIONS SYSTEM VENDOR DRAWINGS) SYSTEM VENDOR DRAWINGS) (WALL MOUNTED) NEW CONCRETE BLOCK www.mgearchitects.com
9. ELECTRICAL/COMMUNICATION OUTLETS SHOWN ARE MINIMUM AS REQUESTED BY OWNER AND ARE FOR ROOM PLANNING PURPOSES ONLY. REFER WALL AA-F000121
STAFF/DUTY STATION (SEE ELECTRICAL AND N
S D NURSE CALL (SEE ELECTRICAL DRAWINGS) CRT OUTLET (SEE FLOOR PLANS)
TO ELECTRICAL DRAWINGS FOR ALL REQUESTED AND REQUIRED OUTLET CONSTRUCTION SPECIFICATIONS. COMMUNICATIONS SYSTEM VENDOR DRAWINGS) S
10. ALL WALL SUPPORT SYSTEM SHALL BE INSTALLED AS PER MANUFACTURER DATA SHEET.
DENOTES BUZZER ACCESS BUTTON (COORDINATE CODE BLUE STATION (SEE ELECTRICAL AND TELEPHONE OUTLET 18" A.F.F. W/ PLASTIC LINED GROMMET WALL OR PARTITION WITH NEW DOOR
B WITH DOOR HARDWARE AND ELECTRICAL DRAWINGS) CB
COMMUNICATION SYSTEMS VENDOR DRWGS.) WITHIN CABINET KNEE SPACE
AND DOOR NUMBER
(COORDINATE WITH DOOR SCHEDULE)
CONSULTANTS:
NOTE: BROKEN LINE DOOR INDICATES

101
DOUBLE ACTING DOOR MEP
TLC Engineering for Architecture
255 South Orange Avenue
GLASS TYPE TAG Orlando, FL 32801 T 407.841.9050
1t
STOREFRONT/WINDOW OR BORROWED FL Registration Number: EB0000015
LIGHT SYMBOL (SEE ELEVATIONS)
STRUCTURAL ENGINEERS
PARTITION TAG
Bliss & Nyitray, Inc.
FA PARTITION CONFIGURATION
A
800 Douglas Road, Suite 300
14 FRAMING /CMU Coral Gables, FL 33134 T 305.442.7086
DESIGNATION
M
FL Registration Number: EB00000674
E F G H J K L N AP
1.1 SEE SHEET A8.01
PARTITION DESIGNATION

UP ELEVATION MARK ELEVATION MARKS (HATCHING DENOTES


NEW, UNHATCHED DENOTES EXISTING)
LABEL ELEVATION IDENTIFICATION
0' - 0" FINISH ELEVATION

12P LABEL
0' - 0"
EXTERIOR ELEVATION
DIRECTION VIEWED
1 DRAWING IDENTIFICATION
A3.01 SHEET IDENTIFICATION

SECTION REFERENCE
PROJECT NAME:
DIRECTION VIEWED
1.8.1 B 5 14P UP DN 1 DRAWING IDENTIFICATION
A4.03 A3.05 SHEET IDENTIFICATION
2.1 74' - 11 7/8"

1 ELECTRICAL
DETAIL REFERENCE

1 DRAWING IDENTIFICATION
ROOM
TOILET TOUCHDOWN 209 A4.01 SHEET IDENTIFICATION
ASST 240 SPACE
Baptist Health South
OFFICE 201 OFFICE PUBLIC
243 227 Florida
CLINICAL 228 OFFICE TOILET
WORKROOM 226 248 REVISION SYMBOL (REFER TO COVER
1

228

226

240

227
208 SHEET FOR REVISION INFORMATION)
20
8 210a
ROOM TAG
15P NAME ROOM NAME IDENTIFICATION
2.8.1

233

207
PUBLIC
PROCEDURE 217 218
TOILET
249
101 ROOM NUMBER IDENTIFICATION Orthopedic Center
ROOM
231 EXAM EXAM EL +10'-6" Interior Renovations
3.1 WORK
RADIOLOGY
233
ROOM
217
ROOM
218
EL +10'-0"
SLAB ELEVATION DIFFERENCE
Design Development
STATIONS CHECK-IN
23 CHECK-OUT
1 247
CAST 207 1 GRID/COLUMN LINE
ROOM
205
EXAM 216 215 EXAM JOB NO: 2015.038
ROOM ROOM DATE: 04-14-2016
23 PUBLIC 216 215 1 AGENCY NUMBER: Checker
20 7 HKPG
5 TOILET A5.03
/4"

224

245a
SUPPLIES SUPPLIES 232
41

2 236 237 2 REVISIONS/SUBMISSIONS :


'-
88

224

232

252 UP
UP 23 23 IT ROOM
6 8 ENTRY
252
AREA
DN BIO WASTE
210
238 WAITING
HALL 1
ROOM DN
223 245d 245 A4.12 DN 16P
TOILET 210c
241

245b
245c

2 EXAM EXAM EXAM CHECK-IN


A0.02 ROOM 220 ROOM EXAM ROOM
213 CHECK-OUT
221 220 ROOM 212 206
213
3 225 212 4
3
22 A5.02
LARGE 5 RADIOLOGY
CONFERENCE 234
ROOM
225 EXAM EXAM 200a SEAL :
WORK ROOM ROOM EXAM

210b
222 219 EXAM ROOM
STATIONS
ROOM 211
246 222 219 214 214 211
17P
234

1
A4.02 210b 5

B
5

A5.02
229

239
23

230

STAFF
OFFICE OFFICE
22 LOUNGE
'- 229 230
91 235 TOUCHDOWN TOUCHDOWN
/8" ASST SPACE ASST TOILET
SPACE
202 244 203 239
242 4
4
JOSE L. ESTEVEZ, AIA AR-0008463
ROLANDO CONESA, AIA AR-0011748
ROBERTO A. SMITH, AIA AR-0010466
113' - 10 1/2" 18P
4.1 5
A4.05
DRAWING TITLE:

PROPOSED PLAN -
4/4/2016 10:00:12 AM

LEVEL 2
1 LEVEL 2 PROPOSED
D E F G H J K M N AP
A2.21 1/8" = 1'-0"

DRAWING NO: A2.21


EQUIPMENT PLAN LEGEND FLOOR PLAN LEGEND
WALL OR PARTITION WITH MEDICAL GAS C.R.T. 18" A.F.F. W/ PLASTIC LINED GROMMET WITHIN CABINET EQUIPMENT IDENTIFICATION SYMBOL W/SCHEDULED EQUIPMENT
WALL OR PARTITION WITH CORNER GUARD (TYP. OUTLETS ABBREVIATIONS ARE AS FOLLOWS: NU-23 ONE HOUR RATED WALL
1. MECHANICAL, PLUMBING AND ELECTRICAL ITEMS ARE SHOWN FOR ROOM LOCATION ONLY. REFER TO ENGINEERING DRAWINGS FOR CONSTRUCTION U.O.N.) (SEE AHCA DETAILS)
V O A N NO H O KNEE SPACE NUMBER (SEE EQUIPMENT SCHEDULE)
OR PARTITION
2 2
SPECIFICATIONS. V = VACUUM N = NITROGEN
O= OXYGEN 2NO = NITRO OXYDE DICTATION EQUIPMENT OUTLET 18" A.F.F. W/ PLASTIC LINED ACCESSORY IDENTIFICATION SYMBOL W/SCHEDULED (SEE PARTITION TYPES)
2. ROOM ACCESSORIES ARE SHOWN FOR THE PURPOSE OF CONTRACTOR ORDERING. REFER TO ACCESSORIES LEGEND, INTERIOR AND / OR A= AIR
D GROMMET WITHIN CABINET KNEE SPACE
A-23
ACCESSORY NUMBER (SEE ACCESSORY LEGEND)
WALL OR PARTITION WITH CORNER GUARD (TYP. 2 H O= WATER
CASEWORK ELEVATIONS FOR EXACT LOCATION. TWO HOUR RATED WALL
U.O.N.) (SEE AHCA DETAILS) 1
3. FURNITURE SHOWN DOTTED AND NOT LABELED WITH THE EQUIPMENT SYMBOL ARE NOT PART OF THE CONTRACT (EXCLUDING MILLWORK) AND IS KP KEY PAD (POWER OPERATED DOOR)
FAX OUTLET 18" A.F.F. W/ PLASTIC LINED GROMMET WITHIN
OR PARTITION
CABINET KNEE SPACE
SHOWN ONLY FOR THE COORDINATION OF ITEMS TO BE INSTALLED. FURNITURE LAYOUT IS GENERAL AND NOT NECESSARILY PERMANENT. CASEWORK / INTERIOR ELEVATION SYMBOL W/ ELEVATION (SEE PARTITION TYPES)
FURNITURE VENDOR IS TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO TO FABRICATION AND INSTALLATION OF FURNITURE. WALL OR PARTITION WITH BUMPER GUARD (TYP. 4 A7.01 2 NUMBER AND SHEET NUMBER (SEE ELEVATION DRAWINGS)
U.O.N.) (SEE AHCA DETAILS) PUSH PLATE (POWER OPERATED DOOR) TELEVISION CONTROL (SEE ELECTRICAL AND TELEVISION
4. AUTOMATIC DOORS AS INDICATED IN PLANS ARE SHOWN TO IDENTIFY THE LOCATION OF PUSH PLATES, OPERATORS AND OTHER ACCESSORIES. PP
VENDOR DRAWINGS)
REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. 3 LEAD LINED WALL
5. DIMENSIONS SHOWN ON EQUIPMENT PLANS ARE FOR THE PURPOSE OF EQUIPMENT LOCATION. COORDINATE EQUIPMENT PLAN DIMENSIONS WITH SINGLE PATIENT STATION (SEE ELECT. AND
DIMENSIONED FLOOR PLANS AND NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND PRIOR TO THE COMMENCEMENT OF WORK. SP COMMUNICATIONS SYSTEM VENDOR DRWGS.) PUBLIC TELEPHONE OUTLET (HC.) DENOTES HANDICAPPED TELEPHONE OUTLET
6. ALL MECHANICAL DUCTWORK/ELECTRICAL CONDUITS/PLUMBING PENETRATIONS THROUGH SMOKE/FIRE PARTITIONS SHALL BE SEALED WITH NEW WALL
LAVORATORY STATION, PULL CORD (SEE ELECTRICAL AND I TELEPHONE OUTLET
SEALANT AND/OR BLOW PATCHES AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE PARTITION AS PER PARTITION TYPE DETAILS. EP COMMUNICATIONS SYSTEM VENDOR DRAWINGS) C INTERCOM (SEE ELECTRICAL DRAWINGS) W
(WALL MOUNTED)
(SEE FLOOR PLANS AND 3081 Salzedo Street, Third Floor
7. SEE EQUIPMENT SCHEDULE SHEET FOR SPECIFIC EQUIPMENT NOTES NOT ADDRESSED IN THIS DRAWING. PARTITION TYPE DETAILS) Coral Gables, FL 33134
8. ALL EQUIPMENT SHALL BE COORDINATED WITH MANUFACTURERS SPECIFICATIONS PRIOR TO INSTALLATION. NOTIFY THE ARCHITECT IF ANY EMERGENCY STATION PUSH BUTTON (SEE ELECTRICAL AND MASTER STATION (SEE ELECTRICAL AND COMMUNICATIONS W TELEPHONE OUTLET T 305 444 0413
E NM
DISCREPANCIES ARE FOUND. COMMUNICATIONS SYSTEM VENDOR DRAWINGS) SYSTEM VENDOR DRAWINGS) (WALL MOUNTED) NEW CONCRETE BLOCK www.mgearchitects.com
9. ELECTRICAL/COMMUNICATION OUTLETS SHOWN ARE MINIMUM AS REQUESTED BY OWNER AND ARE FOR ROOM PLANNING PURPOSES ONLY. REFER WALL AA-F000121
STAFF/DUTY STATION (SEE ELECTRICAL AND N
S D NURSE CALL (SEE ELECTRICAL DRAWINGS) CRT OUTLET (SEE FLOOR PLANS)
TO ELECTRICAL DRAWINGS FOR ALL REQUESTED AND REQUIRED OUTLET CONSTRUCTION SPECIFICATIONS. COMMUNICATIONS SYSTEM VENDOR DRAWINGS) S
10. ALL WALL SUPPORT SYSTEM SHALL BE INSTALLED AS PER MANUFACTURER DATA SHEET.
DENOTES BUZZER ACCESS BUTTON (COORDINATE CODE BLUE STATION (SEE ELECTRICAL AND TELEPHONE OUTLET 18" A.F.F. W/ PLASTIC LINED GROMMET WALL OR PARTITION WITH NEW DOOR
B WITH DOOR HARDWARE AND ELECTRICAL DRAWINGS) CB
COMMUNICATION SYSTEMS VENDOR DRWGS.) WITHIN CABINET KNEE SPACE
AND DOOR NUMBER
(COORDINATE WITH DOOR SCHEDULE)
CONSULTANTS:
NOTE: BROKEN LINE DOOR INDICATES

101
AP N DOUBLE ACTING DOOR MEP

5 4 TLC Engineering for Architecture


A5.02 A5.02 17P GLASS TYPE TAG
255 South Orange Avenue
Orlando, FL 32801 T 407.841.9050
1t
STOREFRONT/WINDOW OR BORROWED FL Registration Number: EB0000015
LIGHT SYMBOL (SEE ELEVATIONS)
ROOF SLAB @ M.P. ROOF SLAB @ M.P. STRUCTURAL ENGINEERS
60' - 8 1/2" 60' - 8 1/2" PARTITION TAG
Bliss & Nyitray, Inc.
FA PARTITION CONFIGURATION 800 Douglas Road, Suite 300
14 FRAMING /CMU Coral Gables, FL 33134 T 305.442.7086
DESIGNATION FL Registration Number: EB00000674
PARTITION DESIGNATION
SEE SHEET A8.01
ELEVATION MARK ELEVATION MARKS (HATCHING DENOTES
NEW, UNHATCHED DENOTES EXISTING)
LABEL ELEVATION IDENTIFICATION
14' - 0"

14' - 0"
0' - 0" FINISH ELEVATION
LABEL
0' - 0"
EXTERIOR ELEVATION
DIRECTION VIEWED
1 DRAWING IDENTIFICATION
ROOF LEVEL A3.01 SHEET IDENTIFICATION
48' - 4"
PG LEVEL 6 PG LEVEL 6
6"

6"
SECTION REFERENCE
46' - 8 1/2" 46' - 8 1/2" PROJECT NAME:
DIRECTION VIEWED
1 DRAWING IDENTIFICATION
A3.05 SHEET IDENTIFICATION

DETAIL REFERENCE
9' - 8"

9' - 8"
1 DRAWING IDENTIFICATION
A4.01 SHEET IDENTIFICATION
Baptist Health South
Florida
REVISION SYMBOL (REFER TO COVER
1 SHEET FOR REVISION INFORMATION)
PG LEVEL 5 PG LEVEL 5
6"

6"
37' - 0 1/2" 37' - 0 1/2" ROOM TAG
25' - 0"

LEVEL 4
35' - 10" NAME ROOM NAME IDENTIFICATION
101 ROOM NUMBER IDENTIFICATION Orthopedic Center
EL +10'-6" SLAB ELEVATION DIFFERENCE
Interior Renovations
EL +10'-0"
Design Development
9' - 8"

9' - 8"
1 GRID/COLUMN LINE

JOB NO: 2015.038


DATE: 04-14-2016
PG LEVEL 4 PG LEVEL 4 AGENCY NUMBER: Checker
6"

27' - 4 1/2" 6" 27' - 4 1/2"


REVISIONS/SUBMISSIONS :

LEVEL 3
23' - 4"
9' - 8"

9' - 8" 6 ELEVATOR & STAIR RENDERING


A5.02

5 5
5
PG LEVEL 3 PG LEVEL 3
11' - 8"
6"

6"

A5.02 A5.02
17' - 8 1/2" 17' - 8 1/2" A5.02
8' - 0"

8"

8"
9' - 8"

9' - 8"

LEVEL 2
11' - 8" SEAL :
8' - 2"

8' - 2"
4' - 4"
PG LEVEL 2 PG LEVEL 2 4 4 4
6"

6"

8' - 0 1/2" 8' - 0 1/2" A5.02 A5.02 A5.02


17' - 8"

17' - 8"
8"

8"
11' - 8"
9' - 8"

9' - 8"

8' - 2"

8' - 2"
JOSE L. ESTEVEZ, AIA AR-0008463
ROLANDO CONESA, AIA AR-0011748
LEVEL 1 ROBERTO A. SMITH, AIA AR-0010466
0"
PG LEVEL 1 PG LEVEL 1 DRAWING TITLE:
6"

-1' - 7 1/2" -1' - 7 1/2"


ELEVATOR PLANS &
4/4/2016 10:00:14 AM

SECTIONS

1 PG LEVEL 1 ELEVATOR 2 PG LEVEL 2-5 ELEVATOR 3 PG LEVEL 6 ELEVATOR


4 NEW ELEVATOR SECTION 1 5 NEW ELEVATOR SECTION 2 A5.02 1/4" = 1'-0" A5.02 1/4" = 1'-0" A5.02 1/4" = 1'-0"
A5.02 1/4" = 1'-0" A5.02 1/4" = 1'-0"

DRAWING NO: A5.02