EQUIPMENT CATALOGUE — TABLE OF CONTENTS


table of contents

table of contents
Contact Information

Transportable Pumps.......................................................................................................................................................................A1

Extinguishing Agents........................................................................................................................................................................B1

Firefighting Equipment Network . ..............................................................................................................................................C1

Nozzles .....................................................................................................................................................................................................D1

Monitors ..................................................................................................................................................................................................E1

Storage Tank Protection - Monitor / Nozzle Packages....................................................................................................F1

Water Supply / Hydrant Section.................................................................................................................................................G1

Transportable Extinguishing Systems....................................................................................................................................H1

Foam Stations........................................................................................................................................................................................ I1

Foam Proportioning, Loose Equipment....................................................................................................................................J1

Storage Tank Protection - Fixed Equipment.........................................................................................................................K1

Hose............................................................................................................................................................................................................L1

Hose Accessories..............................................................................................................................................................................M1

Components for Fire Apparatus..................................................................................................................................................N1

Fixed Foam Storage and Proportioning Systems..............................................................................................................O1

Intellectual Property.......................................................................................................................................................................IP1

WEBSITE
www.williamsfire.com

EMAIL
info@williamsfire.com

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347

contact information CORPORATE
w w w . w CONTACT
i l l i a m s f INFORMATION
ire.com

contact information
CORPORATE CONTACT INFORMATION

24-HR Emergency
409-727-2347
281-999-0276

Toll Free U.S.


800-231-4613

Business Phone
409-745-3232 TEL
409-745-3021 FAX

Physical Address
1675 Texla Rd
Vidor, TX 77662

Post Office Address


P.O. Box 1359
Mauriceville, TX 77626

Internet
www.williamsfire.com
info@williamsfire.com

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347

www.williamsfire.com

TRANSPORTABLE PUMPS
transportable pumps

transportable pumps
SECTION INDEX

Dependapower DPPAT 4025 CAT-R.............................................................................................................................................A2

Patterson/Caterpillar 4,000 GPM

Dependapower DPGOU 6040 CAT-R........................................................................................................................................... A3

Goulds/Caterpillar 6,000 GPM

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
A1
www.williamsfire.com

Transportable Water Pump Systems


transportable pumps

transportable pumps
Product:
Dependapower DPPAT 4025 CAT-R
Patterson/Caterpillar 4,000 GPM

Description:
The Dependapower DPPAT 4025 CAT-R is a trailer mounted, diesel
driven horizontal split case centrifugal fire water pumping system. Nominal
performance rating is 4,000 gpm @ 150 psi (10’ lift). The pump and driver
come mounted on a skid containing an integral 325 gallon fuel cell with level
indicator. The easily detachable skid is transported on a dual-axle trailer. The
12” suction and 10” discharge headers provide minimal pressure loss for maximum efficiency. The 24VDC electrical system
comes standard with two group-D batteries. Paint is basic red polyurethane finish on pump, skid and trailer. (*Not on Driver)
Total Package Weight with Fuel = 15,000 lbs.

Trailer:
Gooseneck style dual axle 14,000 lb. GAWR trailer, complete with: electric
brakes & coupler; DOT lighting package; 235/85 R16 LRF tires/wheels. Deck
areas covered with safety “Grip” surface.

Pump Detail:
Manufacturer Patterson
Series MAA
Model 12 x 8 x 20.3
Fittings Cast iron casting, Bronze trim,
SS packing sleeve
Performance @ Shutoff 200 psi
4,000 gpm - 150 psi / 2,500 gpm - 175 psi
Priming One 24 VDC Electric vane primer & reservoir

Driver Detail:
Manufacturer Caterpillar
Model 3406-DITA
Power 500 BHP @ 2100 rpm
Electrical System 24 VDC
Cooling System Radiator with pusher fan
*Paint Standard base unit Caterpillar yellow

Suction Manifold:
12” diameter flange-fitted header furnished with: four (4) 6” (M) NH inlet
connections, capped & one (1) 2.5” valved (F) NST swivel w/plug.

Discharge Manifold:
10” diameter flange-fitted header, furnished with: four (4) 5” storz discharge connections, capped, with gated discharge
valves: (1) 2.5” (M) valved discharge connections.

Control Panel:
Includes: start/stop switch, tachometer, oil pressure gauge, coolant temperature gauge, amp meter, vernier throttle, com-
pound suction gauge, discharge pressure gauge, fuel pressure gauge, primer valves & switches, hour meter.

Options:
Manual clutch between pump & driver (20’ each - 4 req’d) or (10’ each - 8 req’d)
Four suction hose racks (passenger side only) 6” NH “Light Weight” hard suction hoses
for use with 10’ hoses only (20’ each - 4 req’d) or
SS Suction/Discharge Manifolds (10’ each - 8 req’d)
Jet pump back-up primer 6” Non-floating basket strainers (4 req’d)
Automatic battery charger 6” Floating basket strainers (4 req’d)
Retractable awning over pump operator Full skid cover
6” NH hard suction hoses Add, 2.5” Discharge/Suction
4 Work Lights
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
A2
www.williamsfire.com

Transportable Water Pump Systems


transportable pumps

transportable pumps
Product:
Dependapower DPGOU 6040 CAT-R
Goulds/Caterpillar 6,000 GPM

Description:
The Dependapower DPGOU 6040 CAT-R is a trailer mounted, diesel
driven horizontal split case centrifugal fire water pumping system. Nominal
performance rating is 6,000 gpm @ 150 psi net (10’ lift). Designed to be
moved from one location to another without having to realign the pump cou-
pling. Entire assembly is built on a skid base which also serves as a fuel tank.
Also includes structural frame with lifting lugs and work lights. Electric start
with dual electric primers. Total Package Weight with Fuel = 20,000 lbs.

Trailer:
Triple axle 24,000 lb. GAWR steel decked trailer, complete with; electric brakes and coupler, DOT lighting package;
leveling jack with rear stabilizer jacks; 235/85 R16 tires/wheels.

Pump Detail:
Manufacturer Goulds
Series 3409
Model 10 x 14 x 20 L
Fittings Cast iron casting, Bronze trim
Performance @ Shutoff 200 psi
6,000 gpm - 150 psi
4,000 gpm - 175 psi
Priming Dual 24 VDC Electric

Driver Detail:
Manufacturer Caterpillar
Model 3412-DITA
Power 750 BHP @ 1800 rpm
Electrical System 24 VDC
Cooling System Radiator with pusher fan

Suction Manifold:
14” diameter header, furnished with: six (6) 6” (M) NH inlet con-
nections - capped and one (1) 2.5” valved (F) NST swivel w/plug.

Discharge Manifold:
10” diameter header, furnished with: six (6) 5” Storz discharge
connections, capped, six (6) worm gear operated butterfly valves - 5”,
two (2) 2.5” (M) auxiliary valved discharge connections - capped.

Control Panel:
Includes: start/stop switch, tachometer, oil pressure gauge, cool-
ant temperature gauge, amp meter, vernier throttle, compound suction gauge, discharge pressure gauge, fuel pressure gauge,
primer valves & switches, hour meter.

Options:
Jet pump back-up primer
6” NH hard suction hoses (20’ each - 6 req’d) or (10’ each - 12 req’d)
6” Non-floating basket strainers (6 req’d)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
A3
www.williamsfire.com

EXTINGUISHING AGENTS & ACCESSORIES


extinguishing agents & accessories

extinguishing agents & accessories


SECTION INDEX

ThunderStorm® ATC AR/AFFF — Intro.................................................................................................................................... B2

ThunderStorm® ATC AR/AFFF — 1% x 3% F-601A........................................................................................................B3-B4

ThunderStorm® ATC AR/AFFF — 3% x 3% F-603A . ...................................................................................................B5-B6

ThunderStorm® ATC AR/AFFF — 3% x 6% F-600 ....................................................................................................... B7-B8

ThunderStorm® ATC AR/AFFF — 1% x 6% F-606 Freeze Protected ............................................................... B9-B10

ThunderStorm® ATC AR/AFFF — 3% x 3% F-604 Freeze Protected . ............................................................ B11-B12

ThunderStorm® ATC AR/AFFF — 3% x 6% F-602A Freeze Protected . .........................................................B13-B14

T-STORM™ AR-AFFF 1% x 3% F-701A ............................................................................................................................... B15-B16

T-STORM™ AFFF 3% F-783A .................................................................................................................................................B17-B18

T-STORM™ AFFF 3% F-203A Freeze Protected ........................................................................................................B19-B20

T-STORM™ AR-AFFF 3% x6% F-787A Alcohol-Resistant AFFF ............................................................................B21-B22

“PKW™” Transportable Dry Chemical Skid Unit............................................................................................................ B23

Williams “PKW™” Dry Chemical..............................................................................................................................................B24

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B1
www.williamsfire.com

®
ThunderStorm ATC AR/AFFF
extinguishing agents & accessories

extinguishing agents & accessories


Product:
Overview

Description:
ThunderStorm® ATC 1 x 3 Alcohol Resistant AFFF Concentrate is for-
mulated using a new and proprietary technology. The foam concentrate has a
dramatically reduced viscosity as compared to many other listed polar solvent
type AFFF concentrates on the market. This reduced viscosity enhances per-
formance in all types of foam proportioning equipment including in-line educ-
tors, balanced pressure systems, and built-in systems aboard CFR vehicles.
Additionally, the fire fighting performance of ThunderStorm® ATC is superior to other AR/AFFF foam concentrates.
ThunderStorm® ATC 1 x 3 Concentrate offers many distinct advantages including ease of use and represents a continued
commitment to quality by improving the fire performance of this type of agent on gasoline products while still maintaining
high performance levels on other hydrocarbons as well as polar fuels.
ThunderStorm® ATC 1 x 3 Concentrate is formulated from special fluorochemical and hydrocarbon surfactants, high
molecular weight polymers and solvents. It is transported and stored as a concentrate to provide ease of use and considerable
savings in weight and volume. It contains no PFOS or PFOA and is biodegradable. It is intended for use as a 1% proportioned
solution on hydrocarbon fuels at .10 minimum application density, and as a 3% proportioned solution on polar fuels at .13
minimum application density in fresh, salt or hard water. It may also be stored and used as a premixed solution in fresh potable
water.
There are three fire extinguishing mechanisms in effect when using ThunderStorm® ATC 1 x 3 solution on either a con-
ventional Class B hydrocarbon fuel such as gasoline, diesel fuel, etc., or a Class B polar solvent (water miscible fuel) such as
methyl alcohol, acetone, etc. First, an aqueous film is formed in the case of a conventional hydrocarbon fuel, or a polymeric
membrane in the case of a polar solvent fuel. This film or membrane forms a barrier to help prevent the release of fuel vapor.
Second, regardless of the fuel type, a foam blanket is formed which excludes oxygen and from which drains the liquids that
form the film or the polymeric membrane. Third, the water content of the foam produces a cooling effect.

Proportioning
ThunderStorm® ATC 1 x 3 Alcohol Resistant Concentrate can be easily proportioned (at the correct dilution) using
most conventional proportioning equipment such as:
1. Hydro-Foam™ Nozzles
2. Balanced pressure and in-line balanced pressure pump proportioning equipment.
3. Balanced pressure bladder tank proportioners
4. Around-the-pump and Through-the-pump proportioners
5. Fixed or portable (in-line) venturi proportioners
6. Handline nozzles with fixed induction/pickup tubes

The minimum and maximum usable temperature for ThunderStorm® ATC Concentrate in this equipment is 35°F (2°C)
to 120°F (49°C) respectively.

Typical Physiochemical Propoerties at 77°F/25°C


Appearance Purple Gelled Liquid
Density 1.02 ± 0.01 g/ml
pH 7.5 – 8.5
Refractive Index 1.3600 ± 0.0015
Viscosity 2700 ± 500 CPS*
Spreading Coefficient 4.0 – 6.0
*BROOKFIELD VISCOMETER Spindle #4, Speed 30 RPM

Options:
1% x 3% concentrate
3% x 3% concentrate
3% x 6% concentrate

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B2
www.williamsfire.com
®
ThunderStorm ATC AR/AFFF Application
ThunderStorm® ATC 1X3 can be used on either conventional
extinguishing agents & accessories

extinguishing agents & accessories


Class B fuel or the polar solvent type Class B fuels. Its excellent
1% x 3% F-601A wetting characteristics make it useful in combating Class A fires as
well. Because of the low energy required to make foam, it can be
used with both aspirating and non-aspirating discharge devices. To
Technical Information provide even greater fire protection capability, it may be used with
“PKW™” dry chemical extinguishing agent without regard to the
Description order of application. Hydro-Chem™ Technology is a recommended
ThunderStorm® ATC 1X3 Alcohol Resistant AFFF Concentrate is application for dual agent use on three dimensional fire. Due to the
formulated using a new and proprietary technology. The foam con- velocity of the dry chemical discharge, care must be taken not to sub-
centrate has a dramatically reduced viscosity as compared to other merge the polymeric membrane below the fuel surface when using
1X3 listed polar-solvent type AFFF concentrates on the market. This twin agents on polar fuels.
reduced viscosity enhances performance in all types of foam pro-
portioning equipment including in-line eductors, balanced pressure Fire Performance
systems, and built-in systems aboard CFR vehicles. The fire performance of ThunderStorm® ATC 1X3 Alcohol
Resistant Concentrate is measured primarily against Underwriters
Additionally, the fire fighting performance of ThunderStorm® ATC Laboratories Standard 162 (Latest Revision) and Williams Fire and
is superior to other AR/AFFF foam concentrates. This includes the Hazard Control’s fire test. The UL testing focuses on fuels such as
blended gasoline additive Methyl Tertiary Butyl Ether (MTBE) heptane and isopropyl alcohol while the Williams Fire and Hazard
which is being used as an oxygenate to make gasoline cleaner burn- Control test focuses on premium unleaded gasoline. ThunderStorm®
ing. ThunderStorm® ATC 1X3 Concentrate offers many distinct ATC 1X3 was formulated to provide superior performance on all fire
advantages for ease of use and represents a continued commitment tests, especially important is performance on high octane gasoline.
to quality by improving the fire performance of this type of agent on
gasoline products while still maintaining high performance levels on
other hydrocarbons and polar fuels.
Foaming Properties
When used with fresh, salt or hard water at the correct dilution with
most conventional foam making equipment, the expansion will vary
ThunderStorm® ATC 1X3 Concentrate is formulated from special
depending on the performance characteristics of the equipment.
fluorochemical and hydrocarbon surfactants, high molecular weight
Aspirating discharge devices produce expansion ratios of 5:1 to
polymers and solvents. It is transported and stored as a concentrate
10:1 depending primarily on type of aspirating device and flow rate.
to provide ease of use and considerable savings in weight and vol-
Non-aspirating devices such as handline water fog/stream nozzles
ume. It contains no PFOS or PFOA. It is intended for use as a 1%
or standard sprinkler heads give expansion ratios of 2:1 to 4:1.
proportioned solution on hydrocarbon fuels and as a 3% proportioned
Medium expansion discharge devices produce typical expansion
solution on polar fuels in fresh, salt or hard water. It may also be
ratios between 20:1 to 60:1 depending primarily upon type of device
stored and used as a premixed solution in fresh potable water only.
and operating conditions.
ThunderStorm® ATC 1 x 3 Concentrate is biodegradable.

There are three fire extinguishing mechanisms in effect when using Proportioning
ThunderStorm® ATC 1x3 solution on either a conventional Class ThunderStorm® ATC 1X3 Alcohol Resistant Concentrate can be
B hydrocarbon fuel such as gasoline, diesel fuel, etc., or a Class B easily proportioned (at the correct dilution) using most conventional
polar solvent (water miscible fuel) such as methyl alcohol, acetone, proportioning equipment such as:
etc. First, an aqueous film is formed in the case of a conventional
hydrocarbon fuel, or a polymeric membrane in the case of a polar 1. Hydro-Foam™ Nozzles
solvent fuel. This film or membrane forms a barrier to help prevent 2. Balanced pressure and in-line balanced pressure pump
the release of fuel vapor. Second, regardless of the fuel type, a foam proportioning equipment
blanket is formed which excludes oxygen and from which drains 3. Balanced pressure bladder tank proportioner
the liquids that form the film or the polymeric membrane. Third, the 4. Around-the-pump and Through-the-pump proportioners
water content of the foam produces a cooling effect. 5. Fixed or portable (in-line) venturi proportioners
6. Handline nozzles with fixed induction/ pickup tubes
Typical Physiochemical Propoerties The minimum and maximum usable temperature for ThunderStorm®
at 77°F/25°C ATC Concentrate in this equipment is 35 °F (2 °C) to 120 °F (49 °C)
Appearance Purple Gelled Liquid respectively.
Density 1.02 ± 0.01 g/ml
pH 7.5 – 8.5
Refractive Index 1.3600 ± 0.0015
Storage/Shelf Life
When stored in the packaging supplied (polyethylene totes,
Viscosity 2700 ± 500 CPS*
drums or pails) or in equipment recommended by the manufac-
Spreading Coefficient 4.0 – 6.0
turer and within the temperature ThunderStorm® ATC Technical
Information AR/AFFF 1%x3% F-601A limits specified, the shelf
*BROOKFIELD VISCOMETER Spindle #4, Speed 30 RPM
life of ThunderStorm® ATC 1X3 Alcohol Resistant Concentrate is
about 20-25 years. The factors affecting shelf life and stability for
ThunderStorm® ATC 1x3 Alcohol Resistant Concentrate is a non-
AFFF agents are discussed in detail in Ansul Technical Bulletin
Newtonian fluid that is both pseudoplastic and thixotropic. Because of
No. 54. Freezing of the product should be avoided. If, however, the
these properties, dynamic viscosity will decrease as shear increases.
product is frozen during transport or storage, it must be thawed and
inspected for signs of separation. If separation has occurred, the
product must be mechanically mixed until homogeneous.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B3
www.williamsfire.com

When the concentrate is to be stored in an atmospheric storage tank, a Ordering Information


.125 to .25 in. (3 – 6 mm) layer of mineral oil should be added to seal ThunderStorm® ATC Concentrate is available in pails, drums, totes
the concentrate and minimize the effects of evaporation.
extinguishing agents & accessories

extinguishing agents & accessories


or bulk shipment.

Compatibility 5 gallon pail Part No. 429965


Since ThunderStorm® ATC 1X3 Alcohol Resistant Concentrate is 55 gallon drum Part No. 429964
a unique blend of surfactants, high molecular weight polymers, and 265 gallon tote Part No. 429963
solvents; it is recommended that it not be mixed with any other foam Bulk Part No. 429962
concentrates. Consult Williams Fire and Hazard Control or Ansul
Incorporated with any questions of compatibility. Shipping Weight:
5 gal. (19 L) pail 45 lbs. (20.4 kg)
Materials of Construction Compatibility 55 gal. (208.2 L) drum 495 lbs. (224.5 kg)
Tests have been performed with ThunderStorm® ATC 1X3 Alcohol 265 gal. (1000 L) tote 2463 lbs. (1117 kg)
Resistant Concentrate verifying its compatibility with standard Cube: 5 gal. (19 L) pail 1.25 cu. ft. (.0354 m3)
carbon steel “black” pipe and pipe manufactured from various 55 gal. (208.2 L) drum 11.83 cu. ft. (.3350 m3)
stainless steel or brass compounds. Alternative pipe, plastic fittings, 265 gal. (1000 L) tote 31.50 cu. ft. (.8920 m3)
and valves may be used in some cases if acceptable to the customer
and/or the authority having jurisdiction. Refer to Ansul Technical Important Notice to Purchaser: All statements, technical information
Bulletin No. 59, Form No. F-90109, addressing acceptable materials and recommendations contained herein are based on tests conducted
of construction for use with Ansul foam concentrates. with ThunderStorm® ATC approved equipment, and are believed to
be reliable. But the accuracy or completeness thereof is not guaran-
Galvanized pipe and fittings must not be used in areas where undi- teed, and the following is made in lieu of all warranties, expressed
luted concentrate will contact them since corrosion will result. or implied, including the implied warranties of merchantability and
fitness for purpose:
Please first consult Williams Fire and Hazard Control or Ansul
Incorporated for specific guidelines concerning materials of con- Sellers and manufacturer’s only obligation shall be to replace such
struction. quantity of the product proved to be defective. Before using, user
shall determine the suitability of the product for it’s intended use,
Inspection and user assumes all risk and liability whatsoever in connection there
As with any fire extinguishing agent, ThunderStorm® ATC 1X3 within. NEITHER SELLER NOR MANUFACTURER SHALL BE
Alcohol Resistant Concentrate, whether in the concentrate or pre- LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS
mixed form, should be inspected periodically. NFPA 11 ‘‘Standard OR DAMAGE, DIRECT, INCIDENTAL, OR COINCIDENTAL,
for Low Expansion Foam and Combined Agent Systems’’ requires ARISING OUT OF THE USE OF OR THE INABILITY TO USE
that foam concentrate samples be submitted to the manufacturer or THE PRODUCT. No statement or recommendation not contained
other qualified laboratory for quality condition testing at least annu- herein shall have any force or effect unless in an agreement signed
ally. by officers of seller and manufacturer.

Contact Williams Fire and Hazard Control or Ansul for further


information on annual inspection.

Approvals and Listings


Underwriters Laboratories successfully tested ThunderStorm® ATC
1X3 Concentrate to the requirements contained in U.L. Standard
162, ‘‘Standard for Air-Foam Equipment and Liquid Concentrates.’’
To receive a U.L. listing, the following tests had to be performed
successfully:
Williams Fire & Hazard Control, Inc.
1. Foam Quality Tests P.O. Box 1359 Mauriceville, Texas, USA 77626
2. Class B Hydrocarbon Fuel Fire Tests 24 Hour Emergency Number — 409 -727-2347
3. Class B Polar Solvent Fuel Fire Tests
4. Foam Identification Tests
UL
5. Tests of Shipping Containers

Both 1X3 and 3X3 are currently UL Listed.


The UL Listed Application rate for Hydrocarbons is 0.10 gpm/sq. ft.
The UL Listed Application rate for Alcohols is 0.13 gpm/sq. ft.

In addition to determining agent characteristics, Underwriters


Laboratories lists ThunderStorm® ATC 1X3 concentrate for use One Stanton Street, Marinette, WI 54143-2542
with specific hardware components that also carry the U.L. listing. 715-735-7411
ISO 9001 Registered

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B4
www.williamsfire.com
®
ThunderStorm ATC AR/AFFF Application
ThunderStorm® ATC 3x3 can be used on either conventional Class
extinguishing agents & accessories

extinguishing agents & accessories


B fuel or the polar solvent type Class B fuels. Its excellent wet-
3% x 3% F-603A ting characteristics make it useful in combating Class A fires as
well. Because of the low energy required to make foam, it can be
used with both aspirating and non-aspirating discharge devices. To
Technical Information provide even greater fire protection capability, it may be used with
“PKW™” dry chemical extinguishing agent without regard to the
Description order of application. Hydro-Chem™ Technology is a recommended
ThunderStorm® ATC 3X3 Alcohol Resistant AFFF Concentrate is application for dual agent use on three dimensional fire. Due to the
formulated using a new and proprietary technology. The foam con- velocity of the dry chemical discharge, care must be taken not to sub-
centrate has a dramatically reduced viscosity as compared to other merge the polymeric membrane below the fuel surface when using
3x3 listed polar-solvent type AFFF concentrates on the market. This twin agents on polar fuels.
reduced viscosity enhances performance in all types of foam pro-
portioning equipment including in-line eductors, balanced pressure Fire Performance
systems, and built-in systems aboard CFR vehicles. The fire performance of ThunderStorm® ATC 3x3 Alcohol
Resistant Concentrate is measured primarily against Underwriters
Additionally, the fire fighting performance of ThunderStorm® ATC Laboratories Standard 162 (Latest Revision) and Williams Fire and
is superior to other AR/AFFF foam concentrates. This includes the Hazard Control’s fire test. The UL testing focuses on fuels such as
blended gasoline additive Methyl Tertiary Butyl Ether (MTBE) heptane and isopropyl alcohol while the Williams Fire and Hazard
which is being used as an oxygenate to make gasoline cleaner burn- Control test focuses on premium unleaded gasoline. ThunderStorm®
ing. ThunderStorm® ATC 3x3 Concentrate offers many distinct ATC 3x3 was formulated to provide superior performance on all fire
advantages for ease of use and represents a continued commitment tests, especially important is performance on high octane gasoline.
to quality by improving the fire performance of this type of agent on
gasoline products while still maintaining high performance levels on Foaming Properties
other hydrocarbons and polar fuels. When used with fresh, salt or hard water at the correct dilution with
most conventional foam making equipment, the expansion will vary
ThunderStorm® ATC 3x3 Concentrate is formulated from special depending on the performance characteristics of the equipment.
fluorochemical and hydrocarbon surfactants, high molecular weight Aspirating discharge devices produce expansion ratios of 5:1 to 10:
polymers and solvents. It is transported and stored as a concentrate 1 depending primarily on type of aspirating device and flow rate.
to provide ease of use and considerable savings in weight and vol- Non-aspirating devices such as handline water fog/stream nozzles
ume. It contains no PFOS or PFOA. It is intended for use as a 3% or standard sprinkler heads give expansion ratios of 2:1 to 4:1.
proportioned solution on hydrocarbon fuels and a 3% proportioned Medium expansion discharge devices produce typical expansion
solution on polar fuels in fresh, salt or hard water. It may also be ratios between 20:1 to 60:1 depending primarily upon type of device
stored and used as a premixed solution in fresh potable water only. and operating conditions.
ThunderStorm® ATC 3 x 3 Concentrate is biodegradable.

There are three fire extinguishing mechanisms in effect when using


Proportioning
ThunderStorm® ATC 3x3 Alcohol Resistant Concentrate can be
ThunderStorm® ATC 3x3 solution on either a conventional Class easily proportioned (at the correct dilution) using most conventional
B hydrocarbon fuel such as gasoline, diesel fuel, etc., or a Class B proportioning equipment such as:
polar solvent (water miscible fuel) such as methyl alcohol, acetone,
etc. First, an aqueous film is formed in the case of a conventional 1. Hydro-Foam™ Nozzles
hydrocarbon fuel, or a polymeric membrane in the case of a polar 2. Balanced pressure and in-line balanced pressure pump
solvent fuel. This film or membrane forms a barrier to help prevent proportioning equipment
the release of fuel vapor. Second, regardless of the fuel type, a foam 3. Balanced pressure bladder tank proportioner
blanket is formed which excludes oxygen and from which drains 4. Around-the-pump and Through-the-pump proportioners
the liquids that form the film or the polymeric membrane. Third, the 5. Fixed or portable (in-line) venturi proportioners
water content of the foam produces a cooling effect. 6. Handline nozzles with fixed induction/ pickup tubes

Typical Physiochemical Propoerties The minimum and maximum usable temperature for ThunderStorm®
ATC Concentrate in this equipment is 35 °F (2 °C) to 120 °F (49 °C)
at 77°F/25°C respectively.
Appearance Green Gelled Liquid
Density 1.01 ± 0.01 g/ml
pH 7.5 – 8.5 Storage/Shelf Life
Refractive Index 1.3550 ± 0.0015 When stored in the packaging supplied (polyethylene totes, drums or
Viscosity 2600 ± 500 CPS* pails) or in equipment recommended by the manufacturer and within
Spreading Coefficient 4.5 – 6.5 the temperature limits specified, the shelf life of ThunderStorm®
ATC 3x3 Alcohol Resistant Concentrate is about 20-25 years. The
*BROOKFIELD VISCOMETER Spindle #4, Speed 30 RPM factors affecting shelf life and stability for AFFF agents are discussed
in detail in Ansul Technical Bulletin No. 54. Freezing of the product
ThunderStorm® ATC 3x3 Alcohol Resistant Concentrate is a should be avoided. If, however, the product is frozen during transport
non-Newtonian fluid that is both pseudoplastic and thixotropic. or storage, it must be thawed and inspected for signs of separation.
Because of these properties, dynamic viscosity will decrease as If separation has occurred, the product must be mechanically mixed
until homogeneous.
shear increases.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B5
www.williamsfire.com

When the concentrate is to be stored in an atmospheric storage tank, a Ordering Information


.125 to .25 in. (3 – 6 mm) layer of mineral oil should be added to seal ThunderStorm® ATC Concentrate is available in pails, drums, totes
the concentrate and minimize the effects of evaporation.
extinguishing agents & accessories

extinguishing agents & accessories


or bulk shipment.
5 gallon pail Part No. 430919
Compatibility 55 gallon drum Part No. 430921
Since ThunderStorm® ATC 3x3 Alcohol Resistant Concentrate is a 265 gallon tote Part No. 430922
unique blend of surfactants, high molecular weight polymers, and Bulk Part No. 430918
solvents; it is recommended that it not be mixed with any other foam
concentrates. Consult Williams Fire and Hazard Control or Ansul Shipping Weight:
Incorporated with any questions of compatibility. 5 gal. (19 L) pail 45 lbs. (20.4 kg)
55 gal. (208.2 L) drum 495 lbs. (224.5 kg)
Materials of Construction Compatibility 265 gal. (1000 L) tote 2463 lbs. (1117 kg)
Tests have been performed with ThunderStorm® ATC 3x3 Alcohol Cube: 5 gal. (19 L) pail 1.25 cu. ft. (.0354 m3)
Resistant Concentrate verifying its compatibility with standard 55 gal. (208.2 L) drum 11.83 cu. ft. (.3350 m3)
carbon steel ‘‘black’’ pipe and pipe manufactured from various 265 gal. (1000 L) tote 31.50 cu. ft. (.8920 m3)
stainless steel or brass compounds. Alternative pipe, plastic fittings,
and valves may be used in some cases if acceptable to the customer Important Notice to Purchaser:
and/or the authority having jurisdiction. Refer to Ansul Technical All statements, technical information and recommendations con-
Bulletin No. 59, Form No. F-90109, addressing acceptable materials tained herein are based on tests conducted with ThunderStorm®
of construction for use with Ansul foam concentrates. ATC approved equipment, and are believed to be reliable. But the
accuracy or completeness thereof is not guaranteed, and the follow-
Galvanized pipe and fittings must not be used in areas where undi- ing is made in lieu of all warranties, expressed or implied, including
luted concentrate will contact them since corrosion will result. the implied warranties of merchantability and fitness for purpose:

Please first consult Williams Fire and Hazard Control or Ansul Sellers and manufacturer’s only obligation shall be to replace such
Incorporated for specific guidelines concerning materials of quantity of the product proved to be defective. Before using, user
construction. shall determine the suitability of the product for it’s intended use,
and user assumes all risk and liability whatsoever in connection there
Inspection within. NEITHER SELLER NOR MANUFACTURER SHALL BE
As with any fire extinguishing agent, ThunderStorm® ATC 3x3 LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS
Alcohol Resistant Concentrate, whether in the concentrate or pre- OR DAMAGE, DIRECT, INCIDENTAL, OR COINCIDENTAL,
mixed form, should be inspected periodically. NFPA 11 ‘‘Standard ARISING OUT OF THE USE OF OR THE INABILITY TO USE
for Low Expansion Foam and Combined Agent Systems’’ requires THE PRODUCT. No statement or recommendation not contained
that foam concentrate samples be submitted to the manufacturer or herein shall have any force or effect unless in an agreement signed
other qualified laboratory for quality condition testing at least annu- by officers of seller and manufacturer.
ally.

Contact Williams Fire and Hazard Control or Ansul for further infor-
mation on annual inspection.

Approvals and Listings


Underwriters Laboratories successfully tested ThunderStorm® ATC
3x3 Concentrate to the requirements contained in U.L. Standard
162, ‘‘Standard for Air-Foam Equipment and Liquid Concentrates.’’
To receive a U.L. listing, the following tests had to be performed
successfully:
Williams Fire & Hazard Control, Inc.
1. Foam Quality Tests P.O. Box 1359 Mauriceville, Texas, USA 77626
2. Class B Hydrocarbon Fuel Fire Tests
3. Class B Polar Solvent Fuel Fire Tests UL
®
24 Hour Emergency Number — 409-727-2347
4. Foam Identification Tests
5. Tests of Shipping Containers

Both 1X3 and 3X3 are currently UL Listed.


The UL Listed Application rate for Hydrocarbons is 0.10 gpm/sq. ft.
The UL Listed Application rate for Alcohols is 0.13 gpm/sq. ft.
One Stanton Street, Marinette, WI
In addition to determining agent characteristics, Underwriters 54143-2542
Laboratories lists ThunderStorm® ATC 3x3 concentrate for use with 715-735-7411
specific hardware components that also carry the U.L. listing. ISO 9001 Registered

For US and Foreign Patent and Trademark information,


please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B6
www.williamsfire.com

®
ThunderStorm ATC AR/AFFF prevent the release of fuel vapor. Second, regardless of the
fuel type, a foam blanket is formed which excludes oxygen
3% or 6% F-600
extinguishing agents & accessories

extinguishing agents & accessories


and from which drains the liquids that form the film or the
polymeric membrane. Third, the water content of the foam
produces a cooling effect.
Technical Information
Typical Physiochemical Propoerties
Description
ThunderStorm® F-600 3% or 6% Alcohol Resistant at 77°F/25°C
Concentrate is formulated from special fluorochemical and Appearance Light Amber Gel-Like Liquid
hydrocarbon surfactants, a high molecular weight polymer, Density 0.985 ± 0.050 gm/ml
and solvents. It is transported and stored as a concentrate to pH 7.0 - .8.5
provide ease of use and considerable savings in weight and Refractive Index 1.3475 ± 0.025
volume. Viscosity 2500 ± 500 centipoise*
Spreading 5.7 ± 1.5
It is intended for use as a 3% or 6% proportioned solu- Coefficient
tion (depending on the type of fuel) in fresh, salt or hard *Brookfield Viscometer Spindle #4, Speed 30
water. (Water hardness should not exceed 500 ppm expressed
as calcium and magnesium.) It may also be used and stored as ThunderStorm® F-600 3% or 6% Alcohol Resistant
a premixed solution in fresh or potable water for use with the Concentrate is a non-Newtonian fluid that is both pseudo-
Ansul Model AR-33-D wheeled fire extinguisher. plastic and thixotropic. Because of these properties, dynamic
viscosity will decrease as shear increases.
There are three fire extinguishing mechanisms in effect
when using ThunderStorm® F-600 3% or 6% concentrate (1) TYPE II DISCHARGE OUTLET - A device that
on either a conventional Class B hydrocarbon fuel such as delivers foam onto the burning liquid and partially submerges
gasoline, diesel fuel, etc., or a Class B polar solvent (water the foam or produces restricted agitation of the surface as
miscible fuel) such as methyl alcohol, acetone, etc. First, an described in U.L. 162.
aqueous film is formed in the case of a conventional hydro- (2) U.L. builds in a 5/3 safety factor from its test rate to
carbon fuel, or a polymeric membrane in the case of a polar its recommended rate of application.
solvent fuel. This film or membrane forms a barrier to help (3) TYPE III DISCHARGE OUTLET - A device that
delivers the foam directly onto the burning liquid as described
in U.L. 162.
APPLICATION RATES
Application Rates using U.L. 162 Standard 50 ft.2 Fire Test on representative Application
hydrocarbon and polar solvent fuels are listed below. ThunderStorm® F-600 3% or 6% AFFF is
U.L. Type II Application(1) - Polar Solvents unique among the AFFF agents in that it can
U.L. Test U.L.(2) Recommended be used on either conventional Class B fuels or
Application Rate Application Rate the polar solvent type Class B fuels. Its excel-
Fuel Group Concentration gpm/ft2 (Lpm/m2) gpm/ft.2 lent wetting characteristics make it useful in
(Lpm/m2) combating Class A Fires as well. Because of
Alcohol the low energy to make foam, it can be used
Methanol (MeOH) 6% .06 (2.5) .10 (4.1) with both aspirating and non-aspirating dis-
Ethanol (EtOH) 6% .06 (2.5) .10 (4.1) charge devices.
Isopropanol (IPA) 6% .09 (3.7) .15 (6.1)
Ketone To provide even greater fire protection
Acetone 6% .09 (3.7) .15 (6.1) capability, it can be used with dry chemical
Methyl Ethyl Ketone 6% .09 (3.7) .15 (6.1) extinguishing agents without regard to the
(MEK) order of application to provide even greater
Carboxylic Acid fire protection capability. Due to the velocity
Acetic Acid 6% .10 (4.1) .17 (6.9) of the dry chemical discharge, care must be
Aldehyde taken not to submerge the polymeric mem-
Propionaldehyde 6% .10 (4.1) .17 (6.9) brane below the fuel surface.
Ester
Ethyl Acetate 6% .06 (2.4) .10 (4.1) Fire Performance
Butyl Acetate 6% .06 (2.4) .10 (4.1) Fire Performance - The fire performance
of ThunderStorm® F-600 3% or 6% AFFF
U.L. Type III Application(3) - Hydrocarbons is measured primarily against Underwriters
Heptane 3% .04 (1.6) .10 (4.1) Laboratories Standard 162, 5th Edition. There
Toluene 3% .04 (1.6) .10 (4.1) are no U.S. or foreign government specifica-
Gasoline 3% .04 (1.6) .10 (4.1) tions on this type of product.
10% Gasohol (EtOH) 3% .04 (1.6) .10 (4.1)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B7
www.williamsfire.com

Foaming Properties Galvanized pipe and fittings must not be used in areas
When used with fresh, salt or hard water, at the correct dilution where undiluted concentrate will contact them since corrosion
extinguishing agents & accessories

extinguishing agents & accessories


with most conventional foam making equipment, the expansion will will result.
vary depending on the performance characteristics of the equipment.
Aspirating discharge devices produce expansion ratios of from 5:1 to Please first consult Williams Fire and Hazard Control
10:1 depending primarily on type of aspirating device and flow rate. or Ansul Incorporated for specific guidelines concerning
Non-aspirating devices such as handline water fog/stream nozzles or materials of construction.
standard sprinkler heads give expansion ratios of 2:1 to 4:1.
Inspection
Proportioning As with any fire extinguishing agent, ThunderStorm®
ThunderStorm® F-600 3% or 6% Alcohol Resistant F-600 Concentrate, whether in the concentrate or pre-mixed
Concentrate (ARC) AFFF Concentrate can be easily pro- form, should be inspected periodically. Please refer to the
portioned (at the correct dilution) using most conventional Field Inspection Manual, (Part No. 31274-01), for the detailed
proportioning equipment such as: procedures to perform this inspection. An annual inspection
1. Balanced pressure and in-line balanced pressure is recommended unless unusual conditions of exposure occur
pumped proportioning equipment such as are described in Ansul Technical Bulletin No. 54. In
2. Balanced pressure bladder tank type proportioner such cases, Ansul’s recommendation should be sought.
3. Around-the-pump proportioners
4. Fixed or portable (in-line) venturi type proportioners Approvals and Listings
5. Handline nozzles with fixed induction/ pickup tubes Underwriters Laboratories successfully tested
ThunderStorm® F-600 3% or 6% AFFF to the requirements
The minimum and maximum usable temperature for contained in the U.L. Standard 162, ‘’Standard for Air-Foam
ThunderStorm® F-600 3% or 6% Concentrate in this equip- Equipment and Liquid Concentrates.’’ To receive the U.L.
ment is 35 °F (2 °C) to 120 °F (49 °C) respectively. listing, the following tests had to be performed successfully:
1. Foam Quality Tests
Storage/Shelf Life 2. Class B Hydrocarbon Fuel Fire Tests
When stored in the packaging supplied (polyethylene drums or 3. Class B Polar Solvent Fuel Fire Tests
pails) or in equipment recommended by the manufacturer and within 4. Foam Identification Tests
the temperature limits specified, the shelf life of ThunderStorm® 5. Tests of Shipping Containers
F-600 3% or 6% AFFF is about 20-25 years. The factors affecting 6. Class B Hydrocarbon and Polar Solvent Fuel Sprinkler
shelf life and stability for AFFF Agents are discussed in detail in Tests (Standard type both upright and pendent)
Ansul Technical Bulletin No. 54. Freezing of the product should 7. Subsurface Injection
be avoided. If, however, the product is frozen during transport or
storage, it must be thawed and inspected for signs of separation. If Besides determining agent characteristics, Underwriters
separation has occurred, the product must be mechanically mixed Laboratories lists ThunderStorm® F-600 3% or 6% foam
until homogeneous. concentrate for use with specific hardware components that
also carry the U.L. listing.
When the concentrate is to be stored in an atmospheric
storage tank, a .125 to .25 in. Ordering Information
ThunderStorm® F-600 3% or 6% Alcohol Resistant
(3 - 6 mm) layer of mineral oil should be added to seal AFFF Concentrate is available in pails, drums, totes, or bulk
the concentrate and minimize the effects of evaporation. shipment.
Part No. 431983 5 Gallon Pail
Compatibility Part No. 431984 55 Gallon Drum
Since ThunderStorm® F-600 3% or 6% Alcohol Part No. 431985 256 Gallon Tote
Resistant Concentrate (ARC) is a unique blend of surfactants, Part No. 431986 Bulk
high molecular weight polymers, and solvents; it is recom-
mended that Williams Fire and Hazard Control or Ansul Shipping Weight:
Incorporated be consulted before concentrate is mixed with 5 gal. (19 L) pail - 45 lbs. (20.4 kg)
any other concentrates. 55 gal. (208.1 L) drum - 495 lbs. (224.5 kg)
265 gal. (1000 L) tote - 2463 lbs. (1117 kg)
Materials of Construction Compatibility
Tests have been performed with ThunderStorm® F- Cube:
600 3% or 6% Concentrate verifying its compatibility with 5 gal. (19 L) pail - 1.25 cu. ft. (.0353 m3)
standard carbon steel ‘’black’’ pipe and pipe manufactured 55 gal. (208.1 L) drum - 11.83 cu. ft. (.3350 m3)
from various stainless steel or brass compounds. Alternative 265 gal. (1000 L) tote - 31.50 cu. ft. (.892 m3)
pipe, plastic fittings, and valves may be used in some cases if
acceptable to the customer and/or the authority having juris-
diction. Refer to Ansul Technical Bulletin No. 59, Form No.
F-90109, addressing acceptable materials of construction for
use with Ansul foam concentrates.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B8
www.williamsfire.com
®
ThunderStorm ATC AR/AFFF Fire Performance
The fire performance of ThunderStorm® ATC 1X6 Freeze
1% x 6% F-606
extinguishing agents & accessories

extinguishing agents & accessories


Protected Alcohol-Resistant Concentrate is measured primarily
against Underwriters Laboratories Standard 162 (Latest Revision)
Freeze Protected and Williams Fire & Hazard Control, Inc® fire tests. The UL test-
ing focuses on fuels such as heptane and isopropyl alcohol while
the Williams Fire & Hazard Control, Inc® test focuses on premium
Technical Information unleaded gasoline. ThunderStorm® ATC 1X6 Freeze Protected
Alcohol-Resistant Concentrate was formulated to provide superior
performance on all fire tests; especially on high octane gasoline.
Description
ThunderStorm® ATC 1X6 Freeze Protected Concentrate is
formulated from special fluorochemical and hydrocarbon surfac- Foaming Properties
tants, high molecular weight polymers and solvents. It is transported When used with fresh, salt or hard water at the correct dilution
and stored as a concentrate to provide ease of use and considerable with most conventional foam making equipment; the expansion will
savings in weight and volume. It contains no PFOS or PFOA. It is vary depending on the performance characteristics of the equip-
intended for use as a 1% proportioned solution on hydrocarbon fuels ment. Aspirating discharge devices produce expansion ratios of 5:
and as a 6% proportioned solution on polar solvent fuels in fresh, salt 1 to 10:1 depending primarily on the type of aspirating device and
or hard water. It may also be stored and used as a premixed solution flow rate. Non-aspirating devices such as hand-line water fog/stream
in fresh potable water only. nozzles or standard sprinkler heads give expansion ratios of 2:1 to 4:
1. Medium expansion discharge devices produce typical expansion
There are three fire extinguishing mechanisms in effect when ratios between 20:1 and 60:1 depending primarily on the type of
using ThunderStorm® ATC 1X6 Freeze Protected solution on either device and operating conditions.
a conventional Class B hydrocarbon fuel such as gasoline, diesel
fuel, etc., or a Class B polar solvent (water miscible fuel) such as
methyl alcohol, acetone, etc. First, an aqueous film is formed in the Proportioning
case of a conventional hydrocarbon fuel, or a polymeric membrane ThunderStorm® ATC 1X6 Freeze Protected Alcohol-Resistant
in the case of a polar solvent fuel. This film or membrane forms a Concentrate can be easily proportioned (at the correct dilution) using
barrier to help prevent the release of fuel vapor. Second, regardless most conventional proportioning equipment such as:
of the fuel type, a foam blanket is formed which excludes oxygen 1.HYDRO-FOAM™ Nozzles
and from which drains the liquids that form the film or the polymeric 2.Balanced pressure and in-line balanced pressure pump pro-
membrane. Third, the water content of the foam produces a cooling portioning equipment.
effect. 3.Balanced pressure bladder tank proportioners
4.Around-the-pump and through-the-pump proportioners
5.Fixed or portable (in-line) venturi proportioners
Typical Physiochemical Propoerties 6.Hand-line nozzles with fixed induction/pickup tubes
at 77°F/25°C
The minimum and maximum usable temperature for
Appearance Amber Gelled Liquid ThunderStorm® ATC Concentrate in this equipment is 0°F
Density 1.07 ± 0.01 g/ml (-18°C) to 120°F (49°C) respectively.
pH 7.5 - 8.5
Refractive Index 1.3894 ± 0.0015 Storage/Shelf Life
Viscosity 1000 ± 300 cps* When stored in the packaging supplied (polyethylene totes,
Spreading Coefficient 4.0 - 6.0 drums or pails) or in equipment recommended by the manufac-
*Brookfield Viscometer Spindle #4, Speed 30 rpm turer and within the temperature limits specified, the shelf life of
ThunderStorm® ATC 1X6 Freeze Protected Alcohol-Resistant
ThunderStorm® ATC 1X6 Freeze Protected Alcohol-Resistant Concentrate is about 20-25 years. The factors affecting shelf life and
Concentrate is a non-Newtonian fluid that is both pseudoplastic and stability for AFFF agents are discussed in detail in Ansul Technical
thixotropic. Because of these properties, dynamic viscosity will Bulletin No. 54. Freezing of the product should be avoided. If,
decrease as shear increases. however, the product is frozen during transport or storage, it must
be thawed and inspected for signs of separation. If separation has
Application occurred, the product must be mechanically mixed until homoge-
ThunderStorm® ATC 1X6 Freeze Protected Alcohol-Resistant neous.
Concentrate can be used on either conventional Class B fuel or the
polar solvent type Class B fuels. Its excellent wetting characteristics When the concentrate is to be stored in an atmospheric storage
make it useful in combating Class A fires as well. tank, a .125 to .25 in. (3-6 mm) layer of mineral oil should be added
to seal the concentrate and minimize the effects of evaporation.
Because of the low energy required to make foam, it can be
used with both aspirating and non-aspirating discharge devices. Compatibility
Since it is a unique blend of surfactants, high molecular weight
To provide even greater fire protection capability, it may be polymers, and solvents; it is recommended that ThunderStorm®
used with “PKW” dry chemical extinguishing agent without regard ATC 1X6 Freeze Protected Alcohol-Resistant Concentrate not be
to the order of application. HYDRO-CHEM™ Technology is a rec- mixed with any other foam concentrates. Consult Williams Fire &
ommended application for dual agent use on three-dimensional fires. Hazard Control, Inc® or Ansul Incorporated with any questions of
Due to the velocity of the dry chemical discharge, care must be taken compatibility.
not to submerge the polymeric membrane below the fuel surface
when using the twin agent method on polar solvent fuels.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B9
www.williamsfire.com

Materials of Construction Compatibility Important Notice to Purchaser:


Tests have been performed with ThunderStorm® ATC 1X6 All statements, technical information and recommendations
contained herein are based on tests conducted with ThunderStorm®
extinguishing agents & accessories

extinguishing agents & accessories


Freeze Protected Alcohol-Resistant Concentrate verifying its com-
patibility with standard carbon steel ‘’black’’ pipe and pipe manu- ATC approved equipment, and are believed to be reliable. But the
factured from various stainless steel or brass compounds. Alternative accuracy or completeness thereof is not guaranteed, and the follow-
pipe, plastic fittings, and valves may be used in some cases if accept- ing is made in lieu of all warranties, expressed or implied, including
able to the customer and/or the authority having jurisdiction. Refer the implied warranties of merchantability and fitness for purpose:
to Ansul Technical Bulletin No. 59, Form No. F-90109, addressing
acceptable materials of construction for use with Ansul foam con- Sellers and manufacturer’s only obligation shall be to replace
centrates. such quantity of the product proved to be defective. Before using,
user shall determine the suitability of the product for it’s intended use,
To help prevent corrosion, galvanized pipe and fittings must not and user assumes all risk and liability whatsoever in connection there
be used in areas where they will contact the undiluted concentrate. within. NEITHER SELLER NOR MANUFACTURER SHALL BE
LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS
Please first consult Williams Fire & Hazard Control, Inc® or OR DAMAGE, DIRECT, INCIDENTAL, OR COINCIDENTAL,
Ansul Incorporated for specific guidelines concerning materials of ARISING OUT OF THE USE OF OR THE INABILITY TO USE
construction. THE PRODUCT. No statement or recommendation not contained
herein shall have any force or effect unless in an agreement signed
by officers of seller and manufacturer.
Inspection
As with any fire extinguishing agent, ThunderStorm® ATC
1X6 Freeze Protected Alcohol-Resistant Concentrate, whether in
the concentrate or pre-mixed form, should be inspected periodically.
NFPA 11 “Standard for Low Expansion Foam and Combined Agent
Systems”­’ requires that foam concentrate samples be submitted to
the manufacturer or other qualified laboratory for quality condition
testing at least annually. Contact Williams Fire & Hazard Control,
Inc® or Ansul Incorporated for further information on annual
inspection.

Ordering Information
ThunderStorm® ATC Concentrate is available in pails, drums,
Williams Fire & Hazard Control, Inc.
totes or bulk shipment.
P.O. Box 1359 Mauriceville, Texas, USA 77626
Part No. 432043 5 gallon pail 24 Hour Emergency Number — 409-727-2347
Part No. 432046 55 gallon drum
Part No. 432048 265 gallon tote
Part No. 432049 Bulk

Shipping Weight:
5 gal. (19 L) pail 48 lb. (21.8 kg)
55 gal. (208.2 L) drum 504 lb.(228.6 kg) One Stanton Street, Marinette, WI 54143-2542
265 gal. (1000 L) tote 2750 lb. (1247 kg) 715-735-7411
ISO 9001 Registered
Cube:
5 gal. (19 L) pail 1.25 cu. ft. (.0354 m3)
55 gal. (208.2 L) drum 11.83 cu. ft. (.3350 m3)
265 gal. (1000 L) tote 31.50 cu. ft. (.8920 m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B10
www.williamsfire.com

ThunderStorm® ATC AR/AFFF used on either conventional Class B fuels or the polar solvent
type Class B fuels. Its excellent wetting characteristics make
3% x 3% F-604
extinguishing agents & accessories

extinguishing agents & accessories


it useful in combating Class A Fires as well. Because of the
low energy to make foam, it can be used with both aspirating
Freeze Protected and non-aspirating discharge devices.

To provide even greater fire protection capability, it


Technical Information can be used with dry chemical extinguishing agents without
regard to the order of application to provide even greater fire
Description protection capability. Due to the velocity of the dry chemical
Freeze Protected ThunderStorm® AR-AFFF 3% discharge, care must be taken not to submerge the polymeric
Concentrate is formulated from special fluorochemical and membrane below the fuel surface.
hydrocarbon surfactants, a high molecular weight polymer,
and solvents. It is transported and stored as a concentrate to Fire Performance
provide ease of use and to provide considerable savings in Fire Performance – The fire performance of Freeze
weight and volume. Protected ThunderStorm® AR-AFFF 3% Concentrate is mea-
sured primarily against Underwriters Laboratories Standard
It is intended for use as a 3% proportioned solution in 162, 5th Edition and the Williams Fire & Hazard Control
fresh, salt or hard water (water hardness should not exceed plunging fire test.
500 ppm expressed as calcium and magnesium). It may also
be used and stored as a premixed solution in fresh or potable Foaming Properties
water for use with the Ansul Model AR-33-D wheeled fire When used with fresh, salt or hard water, at the correct
extinguisher. The foam concentrate may be stored at tem- dilution with most conventional foam making equipment, the
peratures to 0˚F (-18˚C) without freezing. If stored below the expansion will vary depending on the performance character-
minimum use temperature freezing may occur. If frozen the istics of the equipment. Aspirating discharge devices produce
concentrate can be thawed and remixed before use. expansion ratios of from 5:1 to 10:1 depending primarily
on type of aspirating device and flow rate. Non-aspirating
There are three fire extinguishing mechanisms in effect devices such as handline water fog/stream nozzles or standard
when using Freeze Protected ThunderStorm® AR-AFFF 3% sprinkler heads give expansion ratios of 2:1 to 4:1.
Concentrate on either a conventional Class B hydrocarbon
fuel such as gasoline, diesel fuel, etc., or a Class B polar Proportioning
solvent (water miscible fuel) such as methyl alcohol, acetone, Freeze Protected ThunderStorm® AR-AFFF 3%
etc. First, an aqueous film is formed in the case of a conven- Concentrate can be proportioned (at the correct dilution)
tional hydrocarbon fuel, or a polymeric membrane in the case using most conventional proportioning equipment such as:
of a polar solvent fuel. This film or membrane forms a barrier 1.Balanced pressure and in-line balanced pressure
to help prevent the release of fuel vapor. Second, regardless pumped proportioning equipment
of the fuel type, a foam blanket is formed which excludes 2.Balanced pressure bladder tank type proportioner
oxygen and from which drains the liquids that form the film 3.Around-the-pump proportioners
or the polymeric membrane. Third, the water content of the 4.Fixed or portable (in-line) venturi type proportioners
foam produces a cooling effect. 5.Handline nozzles with fixed induction/pickup tubes
6.Hydro-foam™ Nozzles
Typical Physiochemical Propoerties
at 77°F/25°C The minimum and maximum usable temperature
Appearance Gel-Like Liquid for Freeze Protected ThunderStorm® AR-AFFF 3%
Density 1.078 ± 0.050 gm/ml Concentrate in this equipment is 0˚ F (-18˚C) to 120˚ F
pH 7.0 – .8.5 (49˚ C) respectively.
Refractive Index 1.3980 ± .0020
Viscosity 2000 ± 300 centipoise* Storage/Shelf Life
Spreading 5.3 ± 1.5 dynes/cm When stored in the packaging supplied (polyethyl-
Coefficient ene drums or pails) or in equipment recommended by the
*Brookfield Viscometer Spindle #4, Speed 30 manufacturer and within the temperature limits specified, the
shelf life of Freeze Protected ThunderStorm® AR-AFFF 3%
Freeze Protected ThunderStorm® AR-AFFF 3% Concentrate is 15-20 years. The factors affecting shelf life
Concentrate is a non-Newtonian fluid that is both pseudo- and stability for AFFF Agents are discussed in detail in Ansul
plastic and thixotropic. Because of these properties, dynamic Technical Bulletin No. 54. Freezing of the product should be
viscosity will decrease as shear increases. avoided. If, however, the product is frozen during transport or
storage, it must be thawed and inspected for signs of separa-
Application tion. If separation has occurred, the product must be mechani-
Freeze Protected ThunderStorm® AR-AFFF 3% cally mixed until homogeneous.
Concentrate is unique among 3% AR-AFFF agents in that the
minimum use temperature is the lowest of all conventional When the concentrate is to be stored in an atmospheric
3% AR-AFFF products on the market. This product can be storage tank, or in containers with large surface area to vol-
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B11
www.williamsfire.com

ume ratios, a .125 to .25 in. (3-6 mm) layer of mineral oil should
be added to seal the concentrate and minimize the effects of
extinguishing agents & accessories

extinguishing agents & accessories


evaporation.

Compatibility
Since Freeze Protected ThunderStorm® AR-AFFF
3% Concentrate is a unique blend of surfactants, high
molecular weight polymers, and solvents; it is recommended
that Williams Fire and Hazard Control, Inc® or Ansul
Incorporated be consulted before concentrate is mixed with Williams Fire & Hazard Control, Inc.
any other concentrates. P.O. Box 1359 Mauriceville, Texas, USA 77626
24 Hour Emergency Number — 409-727-2347
Materials of Construction Compatibility
Tests have been performed with Freeze Protected
ThunderStorm® AR-AFFF 3% Concentrate verifying its
compatibility with standard carbon steel ‘‘black’’ pipe and
pipe manufactured from various stainless steel or brass
compounds. Alternative pipe, plastic fittings, and valves may
be used in some cases if acceptable to the customer and/or One Stanton Street, Marinette, WI
the authority having jurisdiction. Refer to Ansul Technical 54143-2542
Bulletin No. 59, Form No. F-90109, addressing acceptable 715-735-7411
materials of construction for use with Ansul foam concen- ISO 9001 Registered
trates.

Galvanized pipe and fittings must not be used in areas


where undiluted concentrate will contact them since corrosion
will result.

Please first consult Williams Fire and Hazard Control,


Inc® or Ansul Incorporated for specific guidelines concern-
ing materials of construction.

Inspection
The National Fire Protection Association in NFPA 11,
Standard for Low, Medium, and High Expansion Foam, para-
graph 11.6.1 states that fire extinguishing agent, whether in
the concentrate or pre-mixed form, should be inspected annu-
ally. Please refer to the Field Inspection Manual, (Part No.
31274-01), for the detailed procedures to perform this inspec-
tion. An annual inspection is recommended unless unusual
conditions of exposure occur such as are described in Ansul
Technical Bulletin No. 54. In such cases, Ansul’s recommen-
dation should be sought.

Ordering Information
Freeze Protected ThunderStorm® AR-AFFF 3% Concentrate
is available in pails, drums, totes, or bulk shipment.

Part No. 432531 5 Gallon Pail


Part No. 432532 55 Gallon Drum
Part No. 432533 256 Gallon Tote
Part No. 432530 Bulk

Shipping Weight:
5 gal. (19 L) pail – 45 lbs. (20.4 kg)
55 gal. (208.1 L) drum – 495 lbs. (224.5 kg)
265 gal. (1000 L) tote – 2463 lbs. (1117 kg)

Cube:
5 gal. (19 L) pail – 1.25 cu. ft. (.0353 m3)
55 gal. (208.1 L) drum – 11.83 cu. ft. (.3350 m3)
265 gal. (1000 L) tote – 31.50 cu. ft. (.892 m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B12
www.williamsfire.com
®
ThunderStorm ATC AR/AFFF either conventional Class B fuels or the polar solvent type Class
B fuels. Its excellent wetting characteristics make it useful in
3% or 6% F-602A
extinguishing agents & accessories

extinguishing agents & accessories


combating Class A Fires as well. Because of the low energy to
make foam, it can be used with both aspirating and non-aspirat-
Freeze Protected ing discharge devices.
To provide even greater fire protection capability, it can be
used with dry chemical extinguishing agents without regard to
Technical Information the order of application to provide even greater fire protection
capability. Due to the velocity of the dry chemical discharge,
care must be taken not to submerge the polymeric membrane
Description below the fuel surface.
Freeze Protected ThunderStorm® AR-AFFF 3% or 6%
Concentrate is formulated from special fluorochemical and
hydrocarbon surfactants, a high molecular weight polymer, and Fire Performance
solvents. It is transported and stored as a concentrate to provide The fire performance of Freeze Protected ThunderStorm®
ease of use and to provide considerable savings in weight and AR-AFFF 3% or 6% Concentrate is measured primarily against
volume. Underwriters Laboratories Standard 162, 5th Edition and the
Williams Fire & Hazard Control plunging fire test. There are
It is intended for use as a 3% or 6% proportioned solu- no U.S. or foreign government specifications on this type of
tion (depending on the type of fuel) in fresh, salt or hard product.
water. (Water hardness should not exceed 500 ppm expressed
as calcium and magnesium.) It may also be used and stored as Foaming Properties
a premixed solution in fresh or potable water for use with the When used with fresh, salt or hard water, at the correct dilu-
Ansul Model AR-33-D wheeled fire extinguisher. The foam con- tion with most conventional foam making equipment, the expan-
centrate may be stored at temperatures to 0° F (-18° C) without sion will vary depending on the performance characteristics of
freezing. If stored below the minimum use temperature freezing the equipment. Aspirating discharge devices produce expansion
may occur. If frozen the concentrate can be thawed and remixed ratios of from 5:1 to 10:1 depending primarily on type of aspi-
before use. rating device and flow rate. Non-aspirating devices such as han-
dline water fog/stream nozzles or standard sprinkler heads give
There are three fire extinguishing mechanisms in effect expansion ratios of 2:1 to 4:1.
when using Freeze Protected ThunderStorm® AR-AFFF 3% or
6% Concentrate on either a conventional Class B hydrocarbon Proportioning
fuel such as gasoline, diesel fuel, etc., or a Class B polar solvent Freeze Protected ThunderStorm® AR-AFFF 3% or 6%
(water miscible fuel) such as methyl alcohol, acetone, etc. First, Concentrate can be proportioned (at the correct dilution) using
an aqueous film is formed in the case of a conventional hydro- most conventional proportioning equipment such as:
carbon fuel, or a polymeric membrane in the case of a polar sol- 1.Balanced pressure and in-line balanced pressure pumped
vent fuel. This film or membrane forms a barrier to help prevent proportioning equipment
the release of fuel vapor. Second, regardless of the fuel type, a 2.Balanced pressure bladder tank type proportioner
foam blanket is formed which excludes oxygen and from which 3.Around-the-pump proportioners
drains the liquids that form the film or the polymeric membrane. 4.Fixed or portable (in-line) venturi type proportioners
Third, the water content of the foam produces a cooling effect. 5.Handline nozzles with fixed induction/pickup tubes

Typical Physiochemical Propoerties The minimum and maximum usable temperature for Freeze
at 77°F/25°C Protected ThunderStorm® AR-AFFF 3% or 6% Concentrate in
Appearance Light Amber Gel-Like Liquid this equipment is -20°F (-29 °C) to 120 °F (49 °C) respectively.
Density 1.000 ± 0.050 gm/ml
pH 7.0 - .8.5 Storage/Shelf Life
Refractive Index 1.3920 ± .0020 When stored in the packaging supplied (polyethylene drums
Viscosity 1800 ± 300 centipoise* or pails) or in equipment recommended by the manufacturer and
Spreading 6.3 ± 1.5 dynes/cm within the temperature limits specified, the shelf life of Freeze
Coefficient Protected ThunderStorm® AR-AFFF 3% or 6% Concentrate is
*Brookfield Viscometer Spindle #4, Speed 30 about 15-20 years. The factors affecting shelf life and stability for
AFFF Agents are discussed in detail in Ansul Technical Bulletin
Freeze Protected ThunderStorm® AR-AFFF 3% or 6% No. 54. Freezing of the product should be avoided. If, however, the
Concentrate is a non-Newtonian fluid that is both pseudoplastic product is frozen during transport or storage, it must be thawed and
and thixotropic. Because of these properties, dynamic viscosity inspected for signs of separation. If separation has occurred, the
will decrease as shear increases. product must be mechanically mixed until homogeneous.

Application When the concentrate is to be stored in an atmospheric


Freeze Protected ThunderStorm® AR-AFFF 3% or 6% storage tank, or in containers with large surface area to volume
Concentrate is unique among 3% or 6% AR-AFFF agents in that ratios, a .125 to .25 in. (3-6 mm) layer of mineral oil should be
the minimum use temperature is the lowest of all conventional added to seal the concentrate and minimize the effects of evapo-
AR-AFFF products on the market. This product can be used on ration.
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B13
www.williamsfire.com

Compatibility Important Notice to Purchaser:


Since Freeze Protected ThunderStorm® AR-AFFF 3% or All statements, technical information and recommen-
extinguishing agents & accessories

extinguishing agents & accessories


6% Concentrate is a unique blend of surfactants, high molecular dations contained herein are based on tests conducted with
weight polymers, and solvents; it is recommended that Williams ThunderStorm® ATC approved equipment, and are believed
Fire and Hazard Control or Ansul Incorporated be consulted to be reliable. But the accuracy or completeness thereof is not
before concentrate is mixed with any other concentrates. guaranteed, and the following is made in lieu of all warran-
ties, expressed or implied, including the implied warranties of
Materials of Construction Compatibility merchantability and fitness for purpose:
Tests have been performed with Freeze Protected
ThunderStorm® AR-AFFF 3% or 6% Concentrate verifying its Sellers and manufacturer’s only obligation shall be to
compatibility with standard carbon steel ‘’black’’ pipe and pipe replace such quantity of the product proved to be defective.
manufactured from various stainless steel or brass compounds. Before using, user shall determine the suitability of the prod-
Alternative pipe, plastic fittings, and valves may be used in some uct for it’s intended use, and user assumes all risk and liability
cases if acceptable to the customer and/or the authority having whatsoever in connection there within. NEITHER SELLER
jurisdiction. Refer to Ansul Technical Bulletin No. 59, Form No. NOR MANUFACTURER SHALL BE LIABLE EITHER IN
F-90109, addressing acceptable materials of construction for use TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE,
with Ansul foam concentrates. DIRECT, INCIDENTAL, OR COINCIDENTAL, ARISING
OUT OF THE USE OF OR THE INABILITY TO USE THE
Galvanized pipe and fittings must not be used in areas PRODUCT. No statement or recommendation not contained
where undiluted concentrate will contact them since corrosion herein shall have any force or effect unless in an agreement
will result. signed by officers of seller and manufacturer.

Please first consult Williams Fire and Hazard Control or


Ansul Incorporated for specific guidelines concerning materials
of construction.

Inspection
The National Fire Protection Association in NFPA 11,
Standard for Low, Medium, and High Expansion Foam, para-
graph 11.6.1 states that fire extinguishing agent, whether in the
concentrate or pre-mixed form, should be inspected annually.
Williams Fire & Hazard Control, Inc.
Please refer to the Field Inspection Manual, (Part No. 31274-01),
P.O. Box 1359 Mauriceville, Texas, USA 77626
for the detailed procedures to perform this inspection. An annual
inspection is recommended unless unusual conditions of expo- 24 Hour Emergency Number — 409-727-2347
sure occur such as are described in Ansul Technical Bulletin No.
54. In such cases, Ansul’s recommendation should be sought.

Ordering Information
Freeze Protected ThunderStorm® AR-AFFF 3% or 6%
Concentrate is available in pails, drums, totes, or bulk ship-
One Stanton Street, Marinette, WI 54143-2542
ment.
715-735-7411
Part No. 432609 5 Gallon Pail
ISO 9001 Registered
Part No. 432610 55 Gallon Drum
Part No. 432611 256 Gallon Tote
Part No. 432612 Bulk

Shipping Weight:
5 gal. (19 L) pail 45 lbs. (20.4 kg)
55 gal. (208.1 L) drum 495 lbs. (224.5 kg)
265 gal. (1000 L) tote 2463 lbs. (1117 kg)

Cube:
5 gal. (19 L) pail 1.25 cu. ft. (.0353 m3)
55 gal. (208.1 L) drum 11.83 cu. ft. (.3350 m3)
265 gal. (1000 L) tote 31.50 cu. ft. (.892 m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B14
www.williamsfire.com

T-STORM™ AR-AFFF To provide even greater fire protection capability, it may be


used with “PKW” dry chemical extinguishing agent without regard
1% x 3% F-701A
extinguishing agents & accessories

extinguishing agents & accessories


to the order of application. HYDRO-CHEM™ Technology is a rec-
ommended application for dual agent use on three-dimensional fires.
ALCOHOL-RESISTANT AFFF Due to the velocity of the dry chemical discharge, care must be taken
not to submerge the polymeric membrane below the fuel surface
when using the twin agent method on polar solvent fuels.
Technical Information
Fire Performance
Description The fire performance of T-STORM™ 1X3 AR-AFFF, F-701A,
T-STORM™ 1X3 Alcohol-Resistant AFFF (AR-AFFF), F- is measured against Underwriters Laboratories Standard 162 (Latest
701A, is formulated to meet the performance requirements of Revision).
UNDERWRITERS LABORATORIES, Standard for Safety for
Foam Equipment and Liquid Concentrates, UL 162. The foam con- Foaming Properties
centrate has reduced viscosity for use in a wide range of proportion- When used with fresh, salt or hard water at the correct dilution
ing equipment. with most conventional foam making equipment; the expansion will
vary depending on the performance characteristics of the equipment.
T-STORM™ 1X3 AR-AFFF, F-701A, Concentrate is formulat- Aspirating discharge devices produce expansion ratios of 5:1 to 10:
ed from the same fluorochemical and hydrocarbon surfactants, high 1 depending primarily on the type of aspirating device and flow rate.
molecular weight polymers and solvents as THUNDERSTORM® Non-aspirating devices such as hand line water fog/stream nozzles
ATC AR-AFFF, F-601A, but is designed for compliance applica- give expansion ratios of 2:1 to 4:1.
tions. T-STORM™ is transported and stored as a concentrate to
provide ease of use and savings in weight and volume. It contains no Proportioning
PFOS or PFOA. It is intended for use as a 1% proportioned solution T-STORM™ 1X3 AR-AFFF, F-701A, can be easily propor-
on hydrocarbon fuels and as a 3% proportioned solution on polar tioned (at the correct dilution) using most conventional proportion-
solvent fuels in fresh, salt or hard water. It may also be stored and ing equipment such as:
used as a premixed solution in fresh potable water only. 1. HYDRO-FOAM™ Nozzles
2. Balanced pressure and in-line balanced pressure pump pro-
There are three fire extinguishing mechanisms in effect when portioning equipment.
using T-STORM™ 1X3 AR-AFFF, F-701A, solution on either a 3. Balanced pressure bladder tank proportioners
conventional Class B hydrocarbon fuel such as gasoline, diesel fuel, 4. Around-the-pump and through-the-pump proportioners
etc., or a Class B polar solvent (water miscible fuel) such as methyl 5. Fixed or portable (in-line) venturi proportioners
alcohol, acetone, etc. First, an aqueous film is formed in the case of a 6. Hand line nozzles with fixed induction/pickup tubes
conventional hydrocarbon fuel, or a polymeric membrane in the case
of a polar solvent fuel. This film or membrane forms a barrier to help The minimum and maximum usable temperature for T-
prevent the release of fuel vapor. Second, regardless of the fuel type, STORM™ 1X3 AR-AFFF, F-701A, in this equipment is 35 °F (2
a foam blanket is formed which excludes oxygen and from which °C) to 120 °F (49 °C) respectively.
drains the liquids that form the film or the polymeric membrane.
Third, the water content of the foam produces a cooling effect.
Storage/Shelf Life
When stored in the packaging supplied (polyethylene totes,
Typical Physiochemical Propoerties drums or pails) or in equipment recommended by the manufac-
at 77°F/25°C turer and within the temperature limits specified, the shelf life of
Appearance Yellow Gelled Liquid T-STORM™ 1X3 AR-AFFF, F-701A, is about 15-20 years. The fac-
Density 1.02 ± 0.01 g/ml tors affecting shelf life and stability for AFFF agents are discussed
pH 7.5-8.5 in detail in Ansul Technical Bulletin No. 54. Freezing of the product
Refractive Index 1.3540 ± 0.0015 should be avoided. If, however, the product is frozen during transport
Viscosity 2700 ± 500 cps* or storage, it must be thawed and inspected for signs of separation.
Spreading Coefficient 3.0 - 5.0 If separation has occurred, the product must be mechanically mixed
until homogeneous.
*Brookfield Viscometer Spindle #4, Speed 30 rpm
When the concentrate is to be stored in an atmospheric storage
T-STORM™ 1X3 AR-AFFF, F-701A, is a non-Newtonian fluid tank, a 1/8 to 1/4 in. (3-6 mm) layer of mineral oil should be added to
that is both pseudoplastic and thixotropic. Because of these proper- seal the concentrate and minimize the effects of evaporation.
ties, dynamic viscosity will decrease as shear increases.
Compatibility
Application It is recommended that T-STORM™ 1X3 AR-AFFF, F-701A,
T-STORM™ 1X3 AR-AFFF, F-701A, can be used on either not be mixed with any other foam concentrates. Consult Williams
conventional Class B fuel or the polar solvent type Class B fuels. Fire and Hazard Control or Ansul Incorporated with any questions
Because of the low energy required to make foam, it can be used of compatibility.
with both aspirating and non-aspirating discharge devices.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B15
www.williamsfire.com

Materials of Construction Compatibility


Tests have been performed with T-STORM™ 1X3 AR-AFFF,
extinguishing agents & accessories

extinguishing agents & accessories


F-701A, verifying its compatibility with standard carbon steel
“black” pipe and pipe manufactured from various stainless steel
or brass compounds. Alternative pipe, plastic fittings, and valves
may be used in some cases if acceptable to the customer and/or the
authority having jurisdiction. Refer to Ansul Technical Bulletin No.
59, Form No. F-90109, addressing acceptable materials of construc-
tion for use with Ansul foam concentrates. Williams Fire & Hazard Control, Inc.
P.O. Box 1359 Mauriceville, Texas, USA 77626
To help prevent corrosion, galvanized pipe and fittings must not 24 Hour Emergency Number — 409-727-2347
be used in areas where they will contact the undiluted concentrate.

Please first consult Williams Fire and Hazard Control or Ansul


Incorporated for specific guidelines concerning materials of con-
struction.

Inspection One Stanton Street, Marinette, WI 54143-2542


As with any fire extinguishing agent, T-STORM™ 1X3 AR- 715-735-7411
AFFF, F-701A, whether in the concentrate or pre-mixed form, ISO 9001 Registered
should be inspected periodically. NFPA 11 “Standard for Low
Expansion Foam and Combined Agent Systems” requires that foam
concentrate samples be submitted to the manufacturer or other quali-
fied laboratory for quality condition testing at least annually. Contact
Williams Fire and Hazard Control or Ansul Incorporated for further
information on annual inspection.

Approvals and Listings


Underwriters Laboratories successfully tested T-STORM™
1X3 AR-AFFF, F-701A, to the requirements contained in UL 162:
Standard for Air-Foam Equipment and Liquid Concentrates.

Ordering Information
T-STORM™ 1X3 AR-AFFF, F-701A, is available in pails,
drums, totes or bulk shipment.
Part No. 432926 5 gallon pail
Part No. 432929 30 gallon drum
Part No. 432927 55 gallon drum
Part No. 432928 265 gallon tote

Shipping Weight:
5 gal. (19L) pail 45 lb. (20.4 kg)
30 gal. (114L) drum 270 lbs. (122.5 kg)
55 gal. (208.2 L) drum 495 lb. (224.5 kg)
265 gal. (1000 L) tote 2463 lb. (1117kg)

Cube:
5 gal. (19L) pail 1.25cu. ft. (.0354 m3)
30 gal. (114 L) drum 6.45 cu. ft. (0.1827 m3)
55 gal. (208.2 L) drum 11.83 cu. ft. (.3350 m3)
265 gal. (1000 L) tote 31.50cu. ft. (.8920m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B16
www.williamsfire.com

T-STORM™ AFFF acteristics of the equipment. Aspirating discharge devices produce


expansion ratios of from 6:1 to 10:1 depending primarily on type of
3% F-783A
extinguishing agents & accessories

extinguishing agents & accessories


aspirating nozzle and flow rate. Non-aspirating devices such as hand
line water fog/stream nozzles give expansion ratios of 2:1 to 4:1.

Technical Information Proportioning


T-STORM™ 3% AFFF, F-783A, can be easily proportioned (at
Description the correct dilution) using most conventional proportioning equip-
T-STORM™ 3% AFFF, F-783A, is formulated from specialty ment such as:
fluorochemical and hydrocarbon type surfactants along with sol- 1. Balanced pressure and in-line balanced pressure pumped
vents. It is transported and stored as a concentrate to provide ease of proportioning equipment
use and considerable savings in weight and volume. 2. Balanced pressure bladder tank type proportioners
3. Around the pump type proportioners
It is intended for use as a 3% proportioned solution in fresh, 4. Fixed or portable (in-line) venturi type proportioners
salt or hard water. It may also be used and stored as a 3% premixed 5. Hand line nozzles with fixed induction/pickup tubes
solution in fresh or potable water only. The correct proportioning or
mixture ratio is 3 parts of concentrate to 97 parts of water. The minimum and maximum usable temperatures for T-
STORM™ 3% AFFF, F-783A, in this equipment is 35 °F (2 °C) to
Three fire extinguishment mechanisms are in effect when using 120 °F (49 °C) respectively.
T-STORM™ 3% AFFF, F-783A. First, an aqueous film is formed
which works to help prevent the release of fuel vapor. Second, the Storage/Shelf Life
foam blanket from which the film-forming liquid drains effectively When stored in the packaging supplied (polyethylene drums or
excludes oxygen from the fuel surface. Third, the water content of pails) or in equipment recommended by the manufacturer as part of
the foam provides a cooling effect. the foam system within the temperature limits specified, the shelf
life of T-STORM™ 3% AFFF, F-783A, is about 20-25 years. The
Typical Physiochemical Propoerties factors affecting shelf life and stability for T-STORM™ 3% AFFF,
F-783A, are discussed in detail in Ansul Technical Bulletin No. 54.
at 77°F/25°C If the product is frozen during storage or transportation, thawing
Appearance Clear Pale Yellow Liquid
will render the product completely usable. Mixing after freeze thaw
Density 1.011 g/ml
cycling is recommended.
pH 7.5
Refractive Index 1.3640
Spreading Coefficient 5.8 Compatibility
Certain specifications such as U.S. Military Specification
MIL-F-24385 (latest amendment) require that products placed on
Application the Qualified Products List (QPL) for that specification demonstrate
T-STORM™ 3% AFFF, F-783A, is intended for use on Class B
performance compatibility in all mixture proportions.
hydrocarbon fuel fires having low water solubility such as various
crude oils, gasolines, diesel fuels, aviation fuels, etc. It is not suitable
With regard to non-qualified (QPL) AFFF type concentrates,
for use on fuels having appreciable water solubility (polar solvents),
they should only be mixed in an emergency, or if the manufacturer
i.e., methyl and ethyl alcohol, acetone, and methyl ethyl ketone.
has supporting test data to substantiate that the mixture meets the
It can be used with both aspirating and non-aspirating discharge
same requirements as the individual component concentrates. Refer
devices because of the low energy required to make it foam.
to Ansul Technical Bulletin No. 48 for a more detailed discussion of
compatibility.
Its excellent wetting characteristics make it useful in combating
Class A fires as well. It can be used with dry chemical extinguish-
Different types of foam concentrates, i.e., AFFF, protein base,
ing agents without regard to the order of application to provide even
etc., should not be mixed under any circumstances.
greater fire protection capability.

Materials of Construction Compatibility


Fire Performance Tests have been performed with T-STORM™ 3% AFFF, F-
The fire performance of T-STORM™ 3% AFFF, F-783A, is
783A, verifying its compatibility with standard carbon steel “black”
measured against specifications and standards such as U.S. Military
pipe and pipe manufactured from various stainless steel or brass
Specification MIL-24385B but is not on the Qualified Product List
compounds. Alternative pipe, plastic fittings, and valves may be
(QPL). T-STORM™ 3% AFFF, F-783A has also been tested to
used in some cases if acceptable to the customer and/or the authority
Underwriters Laboratories Standard 162 (Latest Edition). Reports
having jurisdiction. Refer to Ansul Technical Bulletin No. 59, Form
covering this fire performance are available on request since stan-
No. F-90109, addressing acceptable materials of construction for use
dards and specifications such as those cited are continuously being
with Ansul foam concentrates.
upgraded and changed.
Galvanized pipe and fittings must not be used in areas where
Foaming Properties undiluted concentrate will contact them since corrosion will result.
When used with fresh or salt water or water of any hardness,
at the correct dilution with most conventional foam making equip- Please first consult Ansul Fire Protection for specific guidelines
ment, the expansion will vary depending on the performance char- concerning materials of construction.
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B17
www.williamsfire.com

Inspection
As with any fire extinguishing agent, T-STORM™ 3% AFFF,
extinguishing agents & accessories

extinguishing agents & accessories


F-783A, whether in the concentrate or pre-mixed form should be
inspected periodically. NFPA 11 “Standard for Low Expansion
Foam and Combined Agent Systems” requires that foam concentrate
samples be submitted to the manufacturer or other qualified labora-
tory for quality condition testing at least annually. Contact Ansul for
further information on annual inspection.
Williams Fire & Hazard Control, Inc.
Approvals and Listings P.O. Box 1359 Mauriceville, Texas, USA 77626
T-STORM™ 3% AFFF, F-783A, is approved, qualified under, 24 Hour Emergency Number — 409-727-2347
listed or meets the requirements of the following specifications and
standards:

Underwriters Laboratories Inc., U.L. Standard 162, Foam


Hardware and Liquid Concentrates (Latest Edition)
1. Foam Quality Tests
2. Class B Hydrocarbon Fuel Fire Tests One Stanton Street, Marinette, WI 54143-2542
3. Foam Identification Tests 715-735-7411
4. Tests of Shipping Containers ISO 9001 Registered
5. Class B Hydrocarbon Fuel Sprinkler Tests (Foam water and
standard type both upright and pendent approvals)

Factory Mutual Research Corporation - Approval Guide

It is impractical for Ansul to list its T-STORM™ 3% AFFF, F-


783A, with every piece of U.L. listed hardware.

Ordering Information
T-STORM™ 3% AFFF, F-783A, is available in pails, drums,
or totes.
5 gal. (19 L) pail Part No. 433164
30 gal. (114 L) drum Part No. 433187
55 gal. (208 L) drum Part No. 433165
25 gal. (1000 L) tote Part No. 433166

Shipping Weight:
5 gal. (19L) pail 45 lbs. (20.4 kg)
30 gal (114 L) drum 270 lbs. (122 kg)
55 gal. (208 L) drum 495 lbs. (225 kg)
265 gal. (1000 L) tote 2463 lbs. (1117kg)

Cube:
5 gal. (19L) pail 1.25 cu. ft. (0.0353m3)
30 gal (114 L) drum 6.45 cu. ft. (0.1827m3)
55 gal. (208 L) drum 11.83 cu. ft. (0.3350m3)
265 gal. (1000 L) tote 31.5 cu. ft. (0.8920m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B18
www.williamsfire.com

T-STORM™ AFFF Fire Performance


The fire performance of T-STORM™ AFFF 3% Freeze
3% F-203A
extinguishing agents & accessories

extinguishing agents & accessories


Protected Concentrate is measured against specifications and
standards such as U.S. Military Specification MIL-F-24385B
FREEZE PROTECTED (latest amendment) and Underwriters Laboratories Standard
UL 162 – 5th Edition. Reports covering this fire performance
Technical Information are available on request since standards and specifications
such as those cited are continuously being upgraded and
Description changed.
T-STORM™ AFFF 3% Freeze Protected Concentrate is
formulated from specialty fluorochemical and hydrocarbon
type surfactants along with solvents. It is transported and Foaming Properties
stored as a concentrate to provide ease of use and consider- When used with fresh salt water or hard water at the
able savings in weight and volume. The foam concentrate correct dilution with most conventional foam making equip-
may be stored at temperatures to -20° F (-29° C) without ment, the expansion will vary depending on the performance
freezing. If stored below the minimum use temperature characteristics of the equipment. Aspirating discharge devices
freezing may occur. If frozen the concentrate can be thawed produce expansion ratios of from 6:1 to 10:1 depending pri-
and remixed before use. marily on type of aspirating device and flow rate. In gen-
eral, the higher the flow rate the higher the expansion ratio.
It is intended for use as a 3% proportioned solution in Subsurface injection is a special case where generally expan-
fresh, salt or hard water. (Water hardness should not exceed sion ratios of 2:1 to 3:1 are preferred but up to 4:1 is allowed.
500 ppm expressed as calcium and magnesium.) It may also Non-aspirating devices such as handline water fog/stream
be used and stored as a 3% premixed solution in fresh or pota- nozzles or standard sprinkler heads give expansion ratios of
ble water only. However, the diluted solution will freeze at 2:1 to 4:1.
32 °F (0 °C). The correct proportioner mixture ratio is 3 parts
concentrate to 97 parts water. Proportioning
T-STORM™ AFFF 3% Freeze Protected Concentrate
Three fire extinguishment mechanisms are in effect when can be proportioned easily at the correct dilution using most
using T-STORM™ AFFF 3% Freeze Protected Concentrate. conventional proportioning equipment such as:
First, an aqueous film is formed which works to help prevent
the release of fuel vapor. Second, the foam blanket from 1. Balanced pressure and in-line balanced pressure
which the film-forming liquid drains effectively excludes pumped proportioning equipment
oxygen from the fuel surface. Third, the water content of the 2. Balanced pressure bladder tank type proportioner
foam provides a cooling effect. 3. Around-the-pump type proportioners
4. Fixed or portable (in-line) venturi type proportioners
Typical Physiochemical Properties 5. Handline nozzles with fixed induction/pickup tubes
at 77°F/25°C The minimum and maximum usable temperatures for
Appearance Purple Gelled Liquid
T-STORM™ AFFF 3% Freeze Protected Concentrate in
Density 1.02 ± 0.01 g/ml
pH 7.5 – 8.5 this equipment is –20 °F (–29 °C) to 120 °F (49 °C) respec-
Refractive Index 1.3600 ± 0.0015 tively.
Viscosity 2700 ± 500 CPS*
Spreading Coefficient 4.0 – 6.0 Storage/Shelf Life
When stored in the packaging supplied (polyethylene
*BROOKFIELD VISCOMETER Spindle #4, Speed 30 RPM drums or pails) or in equipment recommended by the manu-
facturer as part of the foam system and within the tempera-
ThunderStorm® ATC 1x3 Alcohol Resistant Concentrate is a non- ture limits specified, the shelf life of T-STORM™ AFFF 3%
Newtonian fluid that is both pseudoplastic and thixotropic. Because of Freeze Protected Concentrate is about 20-25 years. The fac-
these properties, dynamic viscosity will decrease as shear increases.
tors affecting shelf life and stability for T-STORM™ AFFF
Agents are discussed in detail in Ansul Technical Bulletin No.
Application 54. If the product is frozen during storage or transportation,
T-STORM™ AFFF 3% Freeze Protected concentrate is thawing will render the product completely usable. Mixing
intended for use on Class B hydrocarbon fuel fires having after thawing is desirable so as to assure a homogenous solu-
low water solubility such as various crude oils, gasolines, tion.
diesel fuels, aviation fuels, etc. It is not suitable for use on
fuels having appreciable water solubility (polar solvents), i.e.,
methyl and ethyl alcohol, acetone, and methyl ethyl ketone. It
Compatibility
Although T-STORM™ 3% Freeze Protected Concentrate
can be used with both aspirating and non-aspirating discharge
does not appear on the QPL for MIL-F-24385C, Ansul has
devices because of the low energy required to make it foam.
conducted testing with admixtures of different manufactur-
Its excellent wetting characteristics make it useful in
ers products in varying proportions and is satisfied that the
combating Class A fires as well. It can be used with dry
T-STORM™ 3% Freeze Protected AFFF Concentrate is com-
chemical extinguishing agents without regard to the order of
patible with these products. Refer to Ansul Technical Bulletin
application to provide even greater fire protection capability.
No. 48 for a more detailed discussion of compatibility.
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B19
www.williamsfire.com

Different types of foam concentrates, i.e., AFFF, protein base Important Notice to Purchaser:
extinguishing agents & accessories

extinguishing agents & accessories


etc., should not be mixed under any circumstances. All statements, technical information and recommen-
dations contained herein are based on tests conducted with
Inspection T-STORM™ ATC approved equipment, and are believed to
As with any fire extinguishing agent, T-STORM™ AFFF be reliable. But the accuracy or completeness thereof is not
3% Freeze Protected Concentrate, whether in the concentrate guaranteed, and the following is made in lieu of all warran-
or pre-mixed form, should be inspected periodically. Please ties, expressed or implied, including the implied warranties of
refer to the Field Inspection Manual, Ansul Part No. 31274, merchantability and fitness for purpose:
for the detailed procedures to perform this inspection. An
annual inspection is recommended unless unusual conditions Sellers and manufacturer’s only obligation shall be to
of exposure occur, such as are described in Ansul Technical replace such quantity of the product proved to be defective.
Bulletin No. 54. In such cases, Ansul’s recommendation Before using, user shall determine the suitability of the prod-
should be sought. uct for it’s intended use, and user assumes all risk and liability
whatsoever in connection there within. NEITHER SELLER
Approvals and Listings NOR MANUFACTURER SHALL BE LIABLE EITHER IN
T-STORM™ AFFF 3% Freeze Protected Concentrate is TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE,
approved, qualified under, listed or meets the requirements of DIRECT, INCIDENTAL, OR COINCIDENTAL, ARISING
the following specifications and standards: OUT OF THE USE OF OR THE INABILITY TO USE THE
PRODUCT. No statement or recommendation not contained
Underwriters Laboratories Inc. – U.L. Standard 162 – EX herein shall have any force or effect unless in an agreement
3125 (5th Ed.) signed by officers of seller and manufacturer.

1. Foam Quality Tests


2. Class B Hydrocarbon Fuel Fire Tests
3. Foam Identification Tests
4. Tests of Shipping Containers
5. Class B Hydrocarbon Fuel Sprinkler Tests (Standard
type both upright and pendent approvals only)

It is impractical for Ansul to list its T-STORM™ 3%


agent with every piece of U.L. listed hardware. Moreover,
there are numerous foam hardware components without U.L. Williams Fire & Hazard Control, Inc.
listings that cannot be listed for use with any AFFF agent. P.O. Box 1359 Mauriceville, Texas, USA 77626
24 Hour Emergency Number — 409 -727-2347
Many unlisted pieces of foam hardware should be similar
to those listed. However, on installations where T-STORM™
3% may be used with significantly different hardware compo-
nents than those tested, contact Ansul for recommendations.

Ordering Information One Stanton Street, Marinette, WI


T-STORM™ AFFF 3% Freeze Protected Concentrate is 54143-2542
available in: 715-735-7411
ISO 9001 Registered
Part No. T54783 5 gallon containers
Part No. T54892 55 gallon drums
Part No. T432161 Tote
Part No. T73757 Bulk

Shipping Weight:
5 gal. (19 L) pail 45 lbs. (20.4 kg)
55 gal. (208.1 L) drum 495 lbs. (224.5 kg)
265 gal. (1000 L) tote 2463 lbs. (1117 kg)

Cube:
5 gal. (19 L) pail 1.25 cu. ft. (.0353 m3)
55 gal. (208.1 L) drum 11.83 cu. ft. (.3350 m3)
265 gal. (1000 L) tote 31.50 cu. ft. (.892 m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B20
www.williamsfire.com

T-STORM™ AR-AFFF To provide even greater fire protection capability, it may be


used with “PKW” dry chemical extinguishing agent without regard
3% x6% F-787A
extinguishing agents & accessories

extinguishing agents & accessories


to the order of application. HYDRO-CHEM™ Technology is a rec-
ommended application for dual agent use on three-dimensional fires.
ALCOHOL-RESISTANT AFFF Due to the velocity of the dry chemical discharge, care must be taken
not to submerge the polymeric membrane below the fuel surface
when using the twin agent method on polar solvent fuels.
Technical Information
Fire Performance
Description The fire performance of T-STORM™ 3X6 AR-AFFF, F-787A,
T-STORM™ 3X6 Alcohol-Resistant AFFF (AR-AFFF), F- is measured against Underwriters Laboratories Standard 162 (Latest
787A, is formulated to meet the performance requirements of Revision).
UNDERWRITERS LABORATORIES, Standard for Safety for
Foam Equipment and Liquid Concentrates, UL 162. The foam con- Foaming Properties
centrate has reduced viscosity for use in a wide range of proportion- When used with fresh, salt or hard water at the correct dilution
ing equipment. with most conventional foam making equipment; the expansion will
vary depending on the performance characteristics of the equipment.
T-STORM™ 3X6 AR-AFFF, F-787A, Concentrate is formulat- Aspirating discharge devices produce expansion ratios of 5:1 to 10:
ed from the same fluorochemical and hydrocarbon surfactants, high 1 depending primarily on the type of aspirating device and flow rate.
molecular weight polymers and solvents as THUNDERSTORM® Non-aspirating devices such as hand line water fog/stream nozzles
ATC AR-AFFF, F-601A, but is designed for compliance applica- give expansion ratios of 2:1 to 4:1.
tions. T-STORM™ is transported and stored as a concentrate to
provide ease of use and savings in weight and volume. It contains no Proportioning
PFOS or PFOA. It is intended for use as a 3% proportioned solution T-STORM™ 3X6 AR-AFFF, F-787A, can be easily propor-
on hydrocarbon fuels and as a 6% proportioned solution on polar tioned (at the correct dilution) using most conventional proportion-
solvent fuels in fresh, salt or hard water. It may also be stored and ing equipment such as:
used as a premixed solution in fresh potable water only. 1. HYDRO-FOAM™ Nozzles
2. Balanced pressure and in-line balanced pressure pump pro-
There are three fire extinguishing mechanisms in effect when portioning equipment.
using T-STORM™ 3X6 AR-AFFF, F-787A, solution on either a 3. Balanced pressure bladder tank proportioners
conventional Class B hydrocarbon fuel such as gasoline, diesel fuel, 4. Around-the-pump and through-the-pump proportioners
etc., or a Class B polar solvent (water miscible fuel) such as methyl 5. Fixed or portable (in-line) venturi proportioners
alcohol, acetone, etc. First, an aqueous film is formed in the case of a 6. Hand line nozzles with fixed induction/pickup tubes
conventional hydrocarbon fuel, or a polymeric membrane in the case
of a polar solvent fuel. This film or membrane forms a barrier to help The minimum and maximum usable temperature for T-
prevent the release of fuel vapor. Second, regardless of the fuel type, STORM™ 3X6 AR-AFFF, F-787A, in this equipment is 35 °F (2
a foam blanket is formed which excludes oxygen and from which °C) to 120 °F (49 °C) respectively.
drains the liquids that form the film or the polymeric membrane.
Third, the water content of the foam produces a cooling effect.
Storage/Shelf Life
When stored in the packaging supplied (polyethylene totes,
Typical Physiochemical Propoerties drums or pails) or in equipment recommended by the manufac-
at 77°F/25°C turer and within the temperature limits specified, the shelf life of
Appearance Yellow Gelled Liquid T-STORM™ 3X6 AR-AFFF, F-787A, is about 15-20 years. The fac-
Density 1.01 ± 0.01 g/ml tors affecting shelf life and stability for AFFF agents are discussed
pH 7.5-8.5 in detail in Ansul Technical Bulletin No. 54. Freezing of the product
Refractive Index 1.3460 ± 0.0015 should be avoided. If, however, the product is frozen during transport
Viscosity 1500±500cps* or storage, it must be thawed and inspected for signs of separation.
Spreading Coefficient 4.0 - 6.0 If separation has occurred, the product must be mechanically mixed
until homogeneous.
*Brookfield Viscometer Spindle #4, Speed 30 rpm
When the concentrate is to be stored in an atmospheric storage
T-STORM™ 3X6 AR-AFFF, F-787A, is a non-Newtonian fluid tank, a 1/8 to 1/4 in. (3-6 mm) layer of mineral oil should be added to
that is both pseudoplastic and thixotropic. Because of these proper- seal the concentrate and minimize the effects of evaporation.
ties, dynamic viscosity will decrease as shear increases.
Compatibility
Application It is recommended that T-STORM™ 3X6 AR-AFFF, F-787A,
T-STORM™ 3X6 AR-AFFF, F-787A, can be used on either not be mixed with any other foam concentrates. Consult Williams
conventional Class B fuel or the polar solvent type Class B fuels. Fire and Hazard Control or Ansul Incorporated with any questions
Because of the low energy required to make foam, it can be used of compatibility.
with both aspirating and non-aspirating discharge devices.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B21
www.williamsfire.com

Materials of Construction Compatibility


Tests have been performed with T-STORM™ 3X6 AR-AFFF,
extinguishing agents & accessories

extinguishing agents & accessories


F-787A, verifying its compatibility with standard carbon steel
“black” pipe and pipe manufactured from various stainless steel
or brass compounds. Alternative pipe, plastic fittings, and valves
may be used in some cases if acceptable to the customer and/or the
authority having jurisdiction. Refer to Ansul Technical Bulletin No.
59, Form No. F-90109, addressing acceptable materials of construc-
tion for use with Ansul foam concentrates.
Williams Fire & Hazard Control, Inc.
To help prevent corrosion, galvanized pipe and fittings must not P.O. Box 1359 Mauriceville, Texas, USA 77626
be used in areas where they will contact the undiluted concentrate. 24 Hour Emergency Number — 409-727-2347

Please first consult Williams Fire and Hazard Control or Ansul


Incorporated for specific guidelines concerning materials of con-
struction.

Inspection
As with any fire extinguishing agent, T-STORM™ 3X6 AR- One Stanton Street, Marinette, WI 54143-2542
AFFF, F-787A, whether in the concentrate or pre-mixed form, 715-735-7411
should be inspected periodically. NFPA 11 “Standard for Low ISO 9001 Registered
Expansion Foam and Combined Agent Systems” requires that foam
concentrate samples be submitted to the manufacturer or other quali-
fied laboratory for quality condition testing at least annually. Contact
Williams Fire and Hazard Control or Ansul Incorporated for further
information on annual inspection.

Approvals and Listings


Underwriters Laboratories successfully tested T-STORM™
3X6 AR-AFFF, F-787A, to the requirements contained in UL 162:
Standard for Air-Foam Equipment and Liquid Concentrates.

Ordering Information
T-STORM™ 3X6 AR-AFFF, F-787A, is available in pails,
drums, totes or bulk shipment.
Part No. 431983 5 gallon pail
Part No. 431929 30 gallon drum
Part No. 431984 55 gallon drum
Part No. 431985 265 gallon tote

Shipping Weight:
5 gal. (19L) pail 45 lb. (20.4 kg)
30 gal. (114L) drum 270 lbs. (122 kg)
55 gal. (208 L) drum 495 lb. (224 kg)
265 gal. (1000 L) tote 2463 lb. (1117 kg)

Cube:
5 gal. (19L) pail 1.25cu. ft. (.0354m3)
30 gal. (114 L) drum 6.45 cu. ft. (0.1827 m3)
55 gal. (208 L) drum 11.83cu. ft. (.3350m3)
265 gal. (1000 L) tote 31.50 cu. ft. (.8920m3)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B22
www.williamsfire.com

Hydro-Chem™ Extinguishing System


extinguishing agents & accessories

extinguishing agents & accessories


Product:
“PKW™” Transportable Dry Chemical Skid Unit

Description:
The Williams’ “75 Lb. Dry Chemical Skid” represents a powerful tool
in a small, convenient package to combat pressurized fuelfires. The pack-
age is designed to be mounted in a compartment of a fire truck. Alternately,
a “receiver hitch” version allows it to be easily carried on the rear of most
pickup trucks.
The system is powered by conventional 4,500 PSI air-pack bottles that
can be easily replaced or recharged.
At the heart of this package is a Hydro-Chem™ nozzle. When com-
bined with a pressurized water/foamsource, this system can extinguish a fire
at ranges not possible with conventional equipment.
The unit can provide Dry Chem flows of 5 or 7 Lbs/Second, and water/
foam solution rates of 60, 95, or 125 GPM.
“PKW™” is a highly specialized siliconized Purple-K that is one of the most effective dry chemicals used to extinguish
flammable and/or combustible liquid fires. It is proven even more effective when used in conjunction with The Hydro-
Chem™ Handgun Technology to extinguish pressurized or threedimensional liquid fires. Williams’ “PKW™” is a potassium
bicarbonate-based dry chemical containing chemical additives. The agent is free-flowing, water repellant, non-abrasive, and,
when used as a fire extinguishing agent, will produce no toxic effects.
It’s distinctive, deep purple color provides the firefighter with the ability to stay ON TARGET when the dry chemical is
projected to the fire within the water/foam solution stream. The result, when combined with Hydro-Chem™ Technology, is
the ability to achieve a quicker “knockdown”, in addition to using less chemical to complete the job.

System Includes:
· (2) 50’ sections of 1” flatlay Dry Chemical hose. (For Dry-Chem Use Only)
· Williams’ Hydro-Chem™ Handgun (60, 95, or 125 GPM water/foam solution,
5 or 7 PPS Dry Chem Powder)
· 75 Lb. Dry Chemical Tank
· 75 Lbs of “PKW™” Dry Chemical Powder
· Standard 4500 PSI Refillable air-pack bottle. (Optional)

Weight:
Empty: 150 Lbs
Full: 225 Lbs

“PKW™” Transportable Dry Chemical Skid Unit


PART NO DCU75-60-5 DCU75-95-5 DCU75-125-5
DCU75-60-7 DCU75-95-7 DCU75-125-7
DRY CHEMICAL CAPACITY 75 LBS PKW 75 LBS PKW 75 LBS PKW
WATER/FOAM SOLUTION 60 GPM 95 GPM 125 GPM
FLOW RATE (AT 100 PSI)
DRY CHEMICAL FLOW RATE 5 OR 7 LBS/S 5 OR 7 LBS/S 5 OR 7 LBS/S

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B23
www.williamsfire.com

Dry Chemical - PKW™


extinguishing agents & accessories

extinguishing agents & accessories


Product:
Williams “PKW™” Dry Chemical

Description:
Williams’ “PKW™” is a highly specialized siliconized Purple-K that is one of the most effective dry chemicals used
to extinguish flammable and/or combustible pressurized liquid fires. When used in conjunction with Hydro-Chem™
Technology it effectively controls and extinguishes pressurized or three dimensional “Class B” liquid fires. Its distinctively
deep purple color provides the fire fighter with the ability to stay ON-TARGET when projected to the fire within the foam
and/or water stream. The result, when combined with Hydro-
Chem™ Technology is the ability to achieve a quicker and more
efficient “knockdown,” and extinguishment.
Williams” “PKW™” is a potassium bicarbonate based dry
chemical containing colorized additives. The agent is free-flowing,
water repellent and non abrasive and, when used as a fire extinguish-
ing agent, will produce no toxic effects. “PKW™” dry chemical is
available in 50 pound plastic pails.

NOTE: PKW™ contains 2.05% of Purple dye as compared to


Ansul’s Standard Purple-K containing 0.0143% of the same dye.

Williams’ “PKW™” Dry Chemical


Part No. 423650
Type Siliconized Purple K-Deep Purple Color
Container 50 lb. Plastic Pail
Specific Application For use with Hydro-Chem™ Technology
General Application Class “B” Liquid Fires

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
B24
www.williamsfire.com

FIREFIGHTING EQUIPMENT NETWORK

equipment network
equipment network

CODE Red . ..............................................................................................................................................................................................C2

Williams Fire & Hazard Control, Inc® Equipment Network.........................................................................................C3

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
C1
www.williamsfire.com

equipment network
equipment network

CODE Red
consists of two companies ... Williams Fire & Hazard Control,
Inc® and Ansul acting in unison to bring leading products and
services to the industrial firefighting industry in the form of
Extinguishing Agents including Foams and Powders, Nozzles
and Fittings, Monitors, Hose, Pumps, Trucks, and much more.

Williams Fire & Hazard Control has responded to Land and Sea Fire and related emergencies on
every continent for the last 24 years. Products from the CODE Red group of providers are also
available around the world and are relied upon by industry and governments alike for the inherent
superiority built into every design.

When considering a resource for industry emergency response and the most effective products
made ... Look to Williams Fire & Hazard Control and the CODE Red companies.

For more information visit us at ...

www.williamsfire.com
www.coderedresource.com
or call

800-231-4613
409-745-3232

Thank you,
Dwight Williams
President - Williams Fire & Hazard Control, Inc®

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
C2
www.williamsfire.com

Equipment Network

equipment network
equipment network

Williams Fire & Hazard Control, Inc® proudly represents the following product lines ...
Allied Rubber - Hose and Accessories
American Reel - Hose and Hose Reels
Angus - Fire Hose
Ansul - Foam, PKW, Extinguishers, Bladder Tanks
Arrow Tank - Bladder Tanks
Ashcroft - Gauges
AWG - Storz Adapters and Various Hose Fittings
Badger/Powhatan - Brass Nozzle Valves and Fittings
Barclay - Vacuum Breakers
Bette - Sprinkler Nozzles
C and S Supply - Nozzles
Choctaw - Empty Totes and Drums (New and Reconditioned)
Cla-Val - Automatic Control/Deluge, Pressure Control Valves
Edwards Manufacturing - U.L. Listed Foam Pumps
EIM - Actuators
Elkhart Brass Manufacturing - Nozzles, Monitors, Valves, Etc.
Firetrol - Pump Controllers
Flo-Tork - Actuators
Gitts Manufacturing - Pressure/Vacuum Vents
Guardian Fire Equipment - Brass Adapters, Valves, Nozzles, and Supplies
Hannay - Hose Reels
Harrington - Storz Hardware and Various LDH Hose Fittings and Appliances
Haws - Industrial Safety Showers & Eye Washes
Hilco - Vinyl Covers
KDR Supply - Valves and Flanges
Kedman Co. - Face Shield Brackets
Key - Fire Hose
Kidde - (Powhatan) Brass Adapters, Valves, Nozzles, and Supplies
Kochek - Aluminum Adapters, Storz Fittings and Pump Suction Hoses
Lion Apparel - Bunker Gear and Boots
Mueller - Valves and Strainers
Nibco - Valves
Niedner - Fire Hose and Couplings
Northline - Aluminum Hose Adapters and Storz Adapters
Poly-Corr - Poly Tanks
Potter Roemer - Brass Adapters and Supplies
Pratt - Post Indicator Valves
Raco Industrial - Norris Valves
Service Brass - Brass Adapters and Accesories
Simplex Grinnell - Sprinkler Nozzles
Snap Tite - Fire Hose and Storz Hardware
Stang Industrial Firefighting - Monitors, Nozzles, and Supplies
Task Force Tips - Nozzles and Monitors
Texcel - Pump Suction Hoses
Thunderstorm™ - Foam Concentrates, 1x3, 1x6, 3x3, and 3x6 AFFF/ATC’s
Tyco Valves - Butterfly Valves
W.S. Darley - Safety Equipment and Pump Primers
Wilson Supply - Valves, Flanges, and Supplies
Wirt and Knox - Hose Reels

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
C3
www.williamsfire.com

NOZZLE
nozzles

nozzles
SECTION INDEX

Hydro-Foam™ Technology Overview . .............................................................................................................................D2-D4

Williams’ Nozzle Ranges................................................................................................................................................................D5

Ranger3™ Monitor/Nozzle...........................................................................................................................................................D6

Ranger Lightning.................................................................................................................................................................................D7

HF Ranger™ Select -Automatic/Constant Metering Foam Nozzle ..........................................................................D8

Constant Flow Ranger™ 750, 1000, 1250 & 1500 GPM....................................................................................................D9

Hydro-Air Foam Monitor Nozzles, Medium & Big Body..................................................................................................D10

Ranger™ Automatic - Master Stream Nozzle.....................................................................................................................D11

Hydro-Chem™ Technology Overview . ................................................................................................................................. D12

HC Ranger™-Automatic Hydro-Chem™ Nozzle................................................................................................................D13

“Handgun” Hydro-Chem™ Nozzle............................................................................................................................................D14

Ranger™ Nozzle Part Numbering Chart...............................................................................................................................D15

Monitor Nozzle - “BTM” Series...................................................................................................................................................D16

Premium Monitor Nozzle - “Big Tee” ......................................................................................................................................D17

High Volume Monitor Nozzle - WBB “Big Boy” . ................................................................................................................D18

Hydro-Foam™ Monitor Nozzles Small Body LW Series.................................................................................................D19

Hydro-Foam™ Monitor Nozzles Medium Body HF Series - Elkhart........................................................................ D20

Hydro-Foam™ Monitor Nozzles Medium Body LW 700..................................................................................................D21

Hydro-Foam™ Monitor Nozzles Medium Body LWNS 350, 500 & 750...................................................................D22

Hydrojet Handline Nozzle / Viper Select Series................................................................................................... D23-D24

Air Aspirating Foam Nozzle Model AFN-1............................................................................................................................. D25

Air Aspirating Foam Nozzle Model AFN-2............................................................................................................................ D26

Air Aspirating Handline Nozzles.....................................................................................................................................D27-D28

Foam Wand......................................................................................................................................................................................... D29

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D1
www.williamsfire.com

Hydro-Foam™ Technology
nozzles

nozzles
This proprietary and patented* method of foam pro-
portioning and delivery is the cornerstone upon which our
company has built its reputation. Hydro-Foam™ tech-
nology has been instrumental in Williams Fire & Hazard
Control, Inc.’s® successful extinguishment of numerous
large flammable liquid fires over the past several years.
These incidents were handled successfully with mini-
mum manpower and equipment, primarily because of
the advantages of Hydro-Foam™ technology.

This all-hydraulic system dramatically simplifies the


logistics of moving the high quantities of foam concen-
trate required to extinguish large flammable liquid fires.
Utilizing a small amount of water, high efficiency ventu-
ri-type devices move the foam concentrate from a remote
storage location to a matched Hydro-Foam™ nozzle,
where it is proportioned and delivered to the fire.

Fundamental in design, equipment listed on the fol-


lowing pages utilizes Hydro-Foam™ technology which
provides a simple, efficient, and accurate method of pro-
portioning and delivering foam to the fire.

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D2
www.williamsfire.com

Hydro-Foam™ Technology
nozzles

nozzles
Hydro-Foam™ Technology Overview

Proven Technology
The key role of high-volume foam
delivery devices is to reliably produce
optimum-quality firefighting foam, and
deliver an effective amount to the fire for
the time period needed to achieve extin-
guishment. Hydro-Foam’s™ proven tech-
nology is based on efficient, all-hydraulic,
self educting, non-aspirating nozzle design
and has several distinct advantages.

Simplicity, Reliability, and


Efficiency of Operation
Delivery devices with an all-hydraulic design are simple and reliable because they do not have any moving parts. When
supplied with adequate water pressure and volume, they work.

An efficient self-proportioning design allows the full energy of the available water power to be used to produce a foam
stream with greater range. This design relies on the ease with which the synthetic multi-purpose ThunderStorm® ATC Foam
Concentrates (which are approved for the delivery devices) can be proportioned.

Because less energy is needed to proportion the


foam concentrate with water, the devices can operate
effectively at nozzle pressures of (100 psi) 6.9 bar
or less. An efficient foam-making process is one that
effectively throws foam nearly as far as water. This
means that the nozzle can be located farther from the
fire and still be effective.

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D3
www.williamsfire.com

Hydro-Foam™ Technology
nozzles

nozzles
Simplified Logistics
Hydro-Foam™ delivery devices simplify fire ground
logistics. Self-Educting nozzles operate in conjunction with
special venturi-type devices (Jet Ratio Controllers) that move
large quantities of foam concentrate from remote storage loca-
tions. With Hydro-Foam™ technology, the same firewater
system is used to supply both water and foam concentrate to
the nozzle. This eliminates the need for more elaborate foam
concentrate proportioning and delivery systems which are sus-
ceptible to failure.

High-Quality Foam Stream


With the non-aspirating design, less air is entrained into the
foam solution producing a “dense” bubble as it travels through
the air toward the fire. This produces high quality foam that
is expanded in the optimum range of 3:1 to 5:1. This expan-
sion results in a foam stream that is able to combat atmospheric
winds and penetrate the strong thermal updrafts present in
large-scale storage tank fires.

A high-quality stream is one in which at least 80 percent of


the stream flow from the nozzle lands on the flammable liquid
within a well defined, compact elliptical area (Footprint™).

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D4
nozzles
Williams Fire & Hazard Control, Inc® — Nozzle Ranges
Ambassador™ (6k) 478
Ambassador™ (5k) 458
Ambassador™ (4k) 425
Ambassador™ (3k) 392
Ambassador™ (2k) 317
Ambassador™ (1k) 241
Ranger3™ (3k) 325

409 - 745 - 3232


Ranger3™ (2k) 300

PRODUCT INFORMATION
Ranger3™ (1k) 225
Ranger1.5™ 275
Ranger1.0™ 250
LWNS 750 (Med Body) 160
LWNS 500 (Med Body) 150

D5
LW 700 (Med Body) 160
LW 225 (Small Body) 115
LW 150 (Small Body) 110
HF 500 135
HF350 115
www.williamsfire.com

WBB 1000 200


WBB 750 175
BT 700 165
BT 500 150
BT 350 135
BTM 700 200
BTM 500 190

24-HR EMERGENCY
409 - 727 - 2347
BTM 350 150
75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475
RANGE IN FEET — Nozzle Pressure at 100 PSI

01152005
nozzles
www.williamsfire.com

Ranger3™ Nozzle
nozzles

nozzles
Product:
Ranger3™ Monitor/Nozzle
The Ranger3™, featuring “Smart Nozzle” Technology, was designed for today’s
Industrial fire fighting and protection needs. Hazards involving flammable liquids in
storage and liquids under pressure have met their match with the New Millennium
Equipment from Williams Fire & Hazard Control, Inc®.

The Ranger3™ nozzle combination is capable of not only self-educting foam


concentrate, but can do so while maintaining a nearly constant pressure (+/-10%)
and a constant foam percentage (1% or 3% selectable) regardless of the flow rate.
Discharge flow rates from 1000-3000 USGPM (3800-11356 LPM) can be water only,
Hydro-Foam™ (using jet pumps or automatic constant/selectable metering) or Hydro-
Chem™ for extinguishing liquids and gases under pressure.

Advancing the Fire Fighter’s Ability with Equipment and


Knowledge.
This “Hybrid” nozzle has the unique capability to perform as an automatic pressure or fixed gallonage nozzle. During
automatic operation the nozzle will respond to varying flows to maintain a nearly constant tip pressure, thus maximizing effec-
tive range for a given discharge flow. Once the nozzle reaches the fixed gallonage set point (1000-3000 GPM), it performs
as a conventional fixed gallonage nozzle. This is desirable for foam proportioning operations on storage tank fires or other
hazards requiring specific application rates. This nozzle is capable of Hydro-Foam™ proportioning at rates up to 3000 GPM
@ 3%. It can automatically maintain a nearly constant foam percentage (1% or 3%) throughout the entire flow range while
self-educting. It can optionally be configured to proportion foam from remote locations using jet pump technology (thus for-
feiting the constant/selectable metering feature). The extensive Ranger3™ options list allows this nozzle to be Hydro-Chem™
capable (without Hydro-Foam™ capability) with PKW™ flow rates from 25 lbs/s to 50 lbs/s. Pattern control from straight
stream to full fog is accomplished via a full wrap-around handle attached to the outer sleeve.

*See Williams’ Nozzle Range Chart on page D5

Standard Features List: Options:


Dual Mode Automatic/Fixed Operation Hydro-Chem™ Tip conversion
Fixed Gallonage plugs: 1K, 2K, 3K Choke tubes (25 and 50 lbs/s)
Hydro-Foam™ Constant/Selectable Dry chemical manifolds (4 inlet or 7 inlet)
1% or 3% Nozzle 1.5JP30 Jet Pump w/stinger (one)
Wrap-around handle design for pattern control 2.0JP60 Jet Pump w/stinger (one)
2.5” x 10’’ Dry Chemical Hose
3-2.5” FNST x 3.0” MNPSH Siamese
(Jet to Monitor Supply)
1-2.5” FNST x 3-1.5” MNST Wye
(Jet Pump Supply)
Ranger3™ masterstream option available

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D6
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
Ranger Lightning

Description:
Ranger Lightning is the latest in a series of innovative lightweight Hydro-Foam™, self-contained foam systems as defined by
NFPA standard 1901, Section A-8-3.22.

This rugged design is the first in a series of master stream nozzles to feature Williams Fire & Hazard Control’s Armor-Lyte™
construction.

Armor-Lyte™ is a composite of lightweight, non-corrosive materials that provide years of trouble-free service.

Features
• Self-educts foam concentrate directly from an atmospheric source.
• Selectable gallonage with matched foam proportioning of 1% and 3% at 350, 500, or 750 gpm at 100 psi operating
pressure.
• Flush setting as recommended per NFPA 1964.
• Change flow rate, proportion rate, or flush without the need to
shutdown.
• Positive lock feature for rate selection!
• Self-contained internal stream straightner to maximize range!
• T-handle for pattern control for full fog to straight stream.
• Complete unit weighs only 6 lbs!
• 1.00” MNPT foam inlet port.
• 2.50” FNST Swivel inlet connection.

Options
• Available in Hydro-Chem and Master Stream (water only) versions.
• Actuated pattern control in 12vdc, 24vdc, pneumatic, or hydraulic.
• Nickel-plated brass swivel inlet.
• Nozzles available at: .5% & 1% proportioning selections

Special inlet threads available upon request.

Inlet view Selectable gallonage with matched foam


proportioning of 1% and 3%
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D7
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
HF Ranger™ “Select” - Automatic/Constant Metering
Foam Nozzle

Description:
Introducing the most advanced foam fire fighting nozzle ever made! The
Hydro-Foam™ Ranger™ “Select” Nozzle combines the effective range of
an automatic nozzle, while incorporating the exclusive combination of self
educting/selectable “constant metering” foam proportioning. It is capable of
accurate foam proportioning (Selectable 1% or 3%) over a broad range of
flows (250 - 1500 gpm), while maintaining automatic control of tip pressure
(100 psi +/- 10%) over the entire flow range. This constant nozzle pressure
capability maximizes the effective discharge reach for any given flow. The
discharge pattern is adjustable from full fog to straight stream. Constructed of
anodized aluminum with “wrap around” control handle and protective rubber
bumper. Water inlet is available in nickel plated brass as an option. Manually
operated nozzle is available with automatic controls: 12v; 24v; or hydraulic.

Options:
• 2.5” or 3.5” swivel
• Nickel plated brass swivel
• 12v, 24v or hydraulic pattern activation

Model Ranger™ HFR 1.0 M 2.5* Ranger™ HFR 1.5 M 3.5*


Ranger™ Hydro-Foam™

Water Inlet * 2.5” (F) NH Swivel 3.5” (F) NH Swivel

1.50 M/NPT 2.00 (M) NPT


w/1.5” x 8’ Flexible Pickup w/2” x 8’ Flexible Pickup
Foam Concentrate Inlet *
Hose & 1.5” Rigid PVC Hose & 1.5” Rigid PVC
Drum “Stinger” Drum “Stinger”
Foam/Water Flow
250-1000 gpm 250-1500 gpm
(@ 100 psi)
Proportioning
1% or 3% 1% or 3%
(Selectable)

Application Class “B” Liquid Fires

*Refer to page D14 for complete part# and ordering information


For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D8
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
Constant Flow Ranger™ 750, 1000, 1250 & 1500 GPM

Description:
Water powered nozzle system that proportions and delivers either water
or foam to the hazard area. Fully adjustable from straight stream to full fog.
Constructed of hard anodized aluminum alloy with stainless steel trim. Water inlet
is available in nickel plated brass as an option. Nozzle is supplied with flexible 8
ft. pick-up hose with 1.5” rigid pvc drum “stinger”. Built in select feature provides
proportioning at either 1% or 3%. Fixed foam proportioning may be proportioned
directly from atmospheric source. Manually operated nozzle is also available with
automatic controls: 12v; 24v; or hydraulic. Optional “Jet Pump” is available for
remote proportioning.

Fixed Ranger™ Fixed Ranger™ Fixed Ranger™ Fixed Ranger™


750 1000 1250 1500
Nominal Flow 750 gpm 1000 gpm 1250 gpm 1500 gpm
@100psi
K-Factor 75 100 125 150
Nominal Range 215 ft. 250 ft. 260 ft. 275 ft.
@ 100psi
(straight stream)
Water inlet standard 2.5”NH (F) 2.5”NH (F) 3.5”NH (F) 3.5”NH (F)
Concentrate Inlet 1.5” NPT(M) 1.5” NPT(M) 2” NPT(M) 2” NPT(M)
Proportioning 1% / 3% 1% / 3% 1% / 3% 1% / 3%
without jet

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D9
www.williamsfire.com

Monitor Foam Nozzles, Air Aspirating


nozzles

nozzles
Product:
Hydro-Air Foam Monitor Nozzles, Medium (Not shown)
& Big Body

Description:
Exclusive super-compact, air aspirating foam nozzle with adjustable stream
from full fog to straight stream! Has the appearance of a standard fog/straight
stream monitor nozzle, yet the “Hydro-Air” venturi provides foam expansion ratios
of up to 6:1 by actually inducting air into the center of the master stream. Medium
Body Nozzles are available in lightweight anodized aluminum. Standard flow
rates from 350 to 1500 gpm at 100 psi. As an option, nozzles can be factory modi-
fied to flow from 200 to 1500 gpm at specific inlet pressures.

Air Inlet
Big Body “Ranger™”
Hydro-Air Nozzle
750-1500 GPM

Foam Inlet
(F) NH Swivel

Medium Body Medium Body Medium Body Big Body Big Body Big Body
HA-350 HA-500 HA-700 HA-1000* HA-1250 HA-1500*
Flow @100 psi 350 500 700 1,000 1,250 1,500
Standard inlet 2.5”NH(F) 2.5”NH(F) 2.5”NH(F) 2.5” or 3.5” 2.5” or 3.5” 2.5” or 3.5”
Material Brass Brass Brass Aluminum Aluminum Aluminum

*Refer to page D14 for complete part# and ordering information


For US and Foreign Patent and Trademark information, please refer to page IP

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D10
www.williamsfire.com

Monitor Nozzles
nozzles

nozzles
Product:
Ranger™ Automatic - Master Stream Nozzle

Description:
The Ranger™ Automatic Master Stream Nozzle is made for use
on monitors, ladder pipes, deluge guns and aerial platforms. This noz-
zle’s uniquely-designed constant-pressure feature assures maximum
effective reach for either water or foam/water solution. The tip pres-
sure is automatically controlled to maintain a constant pressure (100 psi
+/- 10%) over the nozzle flow range, which is from 250 gpm to 1,500
gpm. (Other maximum flow stops available). The nozzle pattern is
adjustable from full fog to straight stream. Constructed of anodized
aluminum with exclusive “wrap-around” control handle and protec-
tive bumper. Water/foam solution inlet is available in nickel plated brass
as an option. Nozzle is used in conjunction with an independent foam
proportioning system when applicable. Manually operated nozzle is also avail-
able with automatic controls: 12v; 24v; or hydraulic.

Model Nozzle Pattern Solution Inlet* Solution Rate Material of


Control (GPM) Construction
MSR1.O M 2.5 Manual 2.5” 250-1,000 Anodized Alum.

MSR1.5 M 3.5 Manual 3.5” 250-1,500 Anodized Alum.

MSR1.O A 2.5 12 vdc electric 2.5” 250-1,000 Anodized Alum.

MSR1.5 A 3.5 12 vdc electric 3.5” 250-1,500 Anodized Alum.

MSR1.O B 2.5 24 vdc electric 2.5” 250-1,000 Anodized Alum.

MSR1.5 B 3.5 24 vdc electric 3.5” 250-1,500 Anodized Alum.

MSR1.O H 2.5 Hydraulic 2.5” 250-1,000 Anodized Alum.

MSR1.5 H 3.5 Hydraulic 3.5” 250-1,500 Anodized Alum.

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D11
www.williamsfire.com

Hydro-Chem™ Technology
nozzles

nozzles
The most effective method for extinguishing large pressure and flowing fuel fires.*
By using foam solution as the means to propel, Hydro-Chem™ Systems project dry chemical approximately three to four
times farther than that of conventional dry chemical equipment. Hydro-Chem™ technology gives the firefighter a safer and
more efficient integrated system of delivering dry chemical onto large pressure and flowing fuel fires.

In operation, ground fires are extinguished using foam only. The foam solution applied then “ties-up” or harnesses the
three dimensional fire, greatly reducing flame intensity. After this reduction in heat, dry chemical is then injected into the
foam stream, resulting in a more proficient extinguishment of the fire. Each system is used in conjunction with customer-
provided dry chemical storage equipment.

*Not normally intended for use on liquefied petroleum gas fires.

For US and Foreign Patent and Trademark information, please refIP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D12
www.williamsfire.com

Hydro-Chem™ Nozzle
nozzles

nozzles
Product:
HC Ranger™-Automatic Hydro-Chem™ Nozzle

Description:
The Hydro-Chem™ Ranger™ Nozzle combines the effective range
of an automatic nozzle, while incorporating the dry chemical/foam solu-
tion delivery capabilities of Hydro-Chem™ Technology. Designed to
extinguish three dimensional and oxygenated fuel fires. This unique
nozzle projects dry chemical (@ 20 lbs./sec.) through the center of the
foam/water stream, resulting in an effective range not possible with con-
ventional dry chemical equipment. The constant pressure feature assures
maximum effective reach of the foam/water solution. The tip pressure
is automatically controlled to maintain a constant pressure (100 psi
+/- 10%) over the nozzle flow range, which is from 250 gpm to 1,500
gpm. The discharge pattern is adjustable from full fog to straight stream.
Constructed of anodized aluminum, with “wrap-around” control handle and
protective rubber bumper. Foam solution/water inlet is available in nickel
plated brass as an option. Nozzle is used in conjunction with an indepen-
dent foam proportioning and dry chemical delivery system.

Basic Model# * Nozzle Pattern Water Solution Inlet* Solution Rate (GPM) Material of
Control Construction

HCR1.O M 2.5 Manual 2.5” 250-1,000 Anodized Alum.

HCR1.5 M 3.5 Manual 3.5” 250-1,500 Anodized Alum.

HCR1.O A 2.5 12 vdc electric 2.5” 250-1,000 Anodized Alum.

HCR1.5 A 3.5 12 vdc electric 3.5” 250-1,500 Anodized Alum.

HCR1.O B 2.5 24 vdc electric 2.5” 250-1,000 Anodized Alum.

HCR1.5 B 3.5 24 vdc electric 3.5” 250-1,500 Anodized Alum.

HCR1.O H 2.5 Hydraulic 2.5” 250-1,000 Anodized Alum.

HCR1.5 H 3.5 Hydraulic 3.5” 250-1,500 Anodized Alum.

*Refer to page D14 for complete part# and ordering information


For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D13
www.williamsfire.com

Hydro-Chem™ Nozzles
nozzles

nozzles
Product:
Handgun Hydro-Chem™ Variable Flow Nozzle

Description:
Dual-agent pistol grip handline nozzle incorporates a foam solu-
tion or water application with simultaneous Hydro-Chem™ Technology
which projects dry chemical through the center of the foam/water stream
to achieve ranges not possible with conventional equipment. Used in con-
junction with a separate foam proportioning system.
The foam/water stream is adjustable from full fog to straight stream.
Collar mounted ring adjustment allows quick selection of 60, 95 or 125
gpm flow rates — also features a flush setting. The nozzle features sepa-
rate flow valves for water/foam and dry chemical operations. Constructed
of hard anodized aluminum alloy. Total nozzle weight 7 lbs.

Options Include:
Three inlet valved dry chemical inlet manifold (not shown); flat lay
dry chemical inlet hose, 1.5” x 50’, coupled 1.5 (M) NH; “cross-over”
adapter (for Ansul 350 lb wheeled unit) 1.25” (F) NPSH X 1.5” (M) NH

Part # HCHG-S
NOTE: 1.0” NH (F) Swivel connections also available for
water/foam and dry chemical Water/Foam Flow 60, 95, 125 gpm
Dry Chemical Flow* 5, 7.5, 10 lbs / sec
* Varies depending on dry chemical delivery system and
length of hose lay Water/Foam Solution 1.5” Swivel NH (F)
Inlet NH (F)
For US and Foreign Patent and Trademark information,
please refer to page IP2
Dry Chemical Inlet 1.5” Swivel NH (F)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D14
www.williamsfire.com

Ranger™ AUTOMATIC NOZZLE


HF / HC / MS PART NUMBERING SYSTEM
nozzles

nozzles
R - - - -
VERSION:
HF - Hydro-Foam™
HC - Hydro-Chem™ (1.5” (F)NPT CHEMICAL INLET STD.)
MS - MASTER STREAM

FLOW RANGE:
1.0 250-1000 USGPM - Automatic
1.5 250-1500 USGPM - Automatic
X Special - Fixed Flow or Automatic
(Requires Engineering Approval - Specify As Option)

PROPORTIONING METHOD:
N None (Required for HC & MS Versions)
F Fixed Rate (HF Only)
S Selectable Rate (HF Only)
J Jet Pump (HF Only - Requires Engineering Approval -
Limited to 750 GPM for 3% Proportioning)

PROPORTIONING RATE:
0 None (Required for HC & MS Versions)
.5 .5% (Fixed Only) (1” MNPT Foam Inlet Std)
1 1% (Fixed), .5% (Selectable) (1.5” MNPT Foam Inlet Std)
3 3% (Fixed), 1-3% (Selectable) (2” MNPT Foam Inlet Std)
X Special (Requires Engineering Approval)

PATTERN CONTROL:
M Manual
A 12VDC Actuated
B 24VDC Actuated
H Hydraulic
X Special

INLET CONNECTIONS:
2.5 2.5” FNST (Standard on 1.0 Flow Range)
3.5 3.5” FNST (Standard on 1.5 Flow Range)
64 64MM (2.5”) FBSP
89 89MM (3.5”) FBSP
X Special (Requires Engineering Approval)

OPTIONS:
0 None
1 90˚ Swivel w/1.5” FNPT Foam/Chemical Inlet Port (Not recommended for HF1.5)
2 90˚ Swivel w/1.5” FNST Swivel Foam/Chemical Inlet Port (Not recommended for HF1.5)
3 Nickel Plated Brass Inlet Nut in Lieu of Standard Anodized Aluminum
4 Straight 1.5” FNST Swivel Foam/Chemical Inlet Port (Not recommended for HF1.5)
5 Straight 1.5” FNPT Rigid Foam/Chemical Inlet Port (Standard on HC - Not recommended for HF1.5)
6 Male Cam-Lock Foam/Chemical Inlet Port (Same as Standard Size for Nozzle Configuration)
7 Manual ON/OFF 1-3% Metering Valve
A Automatic w/Maximum Flow Stop (Requires Engineering Approval)
F Fixed Flow Maximum Stop Non-Automatic (Requires Engineering Approval)
X Special (Requires Engineering Approval)

NOTE:
All “X” Selections Require Engineering Approval Prior to Ordering —
A Detailed Description Must be Provided When Placing Order

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D15
www.williamsfire.com

Monitor Nozzles
nozzles

nozzles
Product:
Monitor Nozzle - “BTM” Series

Description:
Standard industrial grade master stream nozzle. Fully adjustable from
straight stream to full fog. Cast brass construction. Standard flow rates of 350,
500, and 700 gpm at 100 psi nozzle pressure. As an option, nozzle can be fac-
tory modified to any flow between 100 to 700 gpm at 100 psi (i.e. any K Factor
between 10 and 70). Abbreviated style cast control handles. Standard jam nut
locks foam or water stream at desired pattern. 2.5” NH (F) rigid inlet.

Range Straight
Model Flow @100 psi K-Factor Inlet Material
Stream
BTM-350 350 35 2.5” NH (F) 150 ft. Cast Brass
BTM-500 500 50 2.5” NH (F) 190 ft. Cast Brass
BTM-700 700 70 2.5” NH (F) 200 ft. Cast Brass

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D16
www.williamsfire.com

Monitor Nozzles
nozzles

nozzles
Product:
Premium Monitor Nozzle - “Big Tee”

Description:
Premium grade industrial master stream nozzle with exclusive
“flush” feature. In flush position, nozzle will purge particulates up
to .25” diameter. Fully adjustable from straight stream to full fog.
Large composite rubber covered brass handles for positive stream
control. All brass construction. Standard flow rates are 350 and
500 at 100 psi nozzle pressure.

Model Flow @100 psi K-Factor Inlet Range Straight Material


Stream
BT-350 350 gpm 35 2.5” NH (F) Swivel 135 ft. Cast Brass
BT-500 500 gpm 50 2.5” NH (F) Swivel 150 ft. Cast Brass

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D17
www.williamsfire.com

Monitor Nozzles
nozzles

nozzles
Product:
High Volume Monitor Nozzle - WBB “Big Boy”

Description:
High-volume, industrial-grade, master stream nozzle. Fully adjust-
able from straight stream to full fog. Cast brass construction. Standard
flow rates of 750, and 1000 gpm at 100 psi. Abbreviated style cast
control handles. Standard jam nut locks foam or water stream at desired
pattern. Available with either 2.5” or 3.5” NH (F) inlet.

Model Flow @100 psi K-Factor Inlet(s) Range Straight Material


Stream
WBB-750 750 gpm 75 2.5” / 3.5” NH (F) 175 ft. Cast Brass
WBB-1000 1000 gpm 100 2.5” / 3.5” NH (F) 200 ft. Cast Brass

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D18
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
Hydro-Foam™ Monitor Nozzles — 
Small Body LW Series

Description:
Patented water powered nozzle system that proportions and delivers
either water or foam to the hazard area. Fully adjustable from straight
stream to full fog with flows of 150 or 225 gpm. Brass construction with
stainless steel trim. Foam is proportioned directly from an atmospheric
source at 1%, 3% or 6%.

Model # Flow Range Range@100psi Water inlet Concentrate K-factor Proportioning


Hydro-Foam™ @100psi @100psi (narrow fog) inlet
Nozzle (straight
stream)
Small Body 150 gpm 110 ft. 60 ft. 1.5”NH 1”NPT(M) 15 1%, 3% or 6%
LW150 (F)swivel
Small Body 225 gpm 115 ft. 65 ft. 1.5”NH 1”NPT(M) 22.5 1%, 3% or 6%
LW225 (F)swivel
For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D19
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
Hydro-Foam™ Monitor Nozzles —
Medium Body HF Series - Elkhart

Description:
Patented water powered nozzle system that proportions and delivers either water
or foam to the hazard area. Fully adjustable from straight stream to full fog with
flows of 350 or 500 gpm. Brass construction with stainless steel trim. Nozzle comes
complete with 1” X 8 ft. flexible pick-up hose. Optional 1% or 3% selector provides
dual proportioning capability. Foam concentrate is proportioned directly from an
atmospheric source.

Model # Flow Range Range Water Concentrate K-factor Proportioning


Hydro-Foam™ @100psi @100psi @100psi inlet inlet
Nozzle (straight (narrow fog)
stream)
HF 350 350 gpm 145 ft. 65 ft. 2.5”NH 1”NPT(M) 35 1%, 3%
(F)swivel

HF 500 500 gpm 155 ft. 75 ft. 2.5”NH 1”NPT(M) 50 1%, 3%


(F)swivel

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D20
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
Hydro-Foam™ Monitor Nozzles —
Medium Body LW 700

Description:
Patented water powered nozzle system that proportions and delivers
either water or foam to the hazard area. Fully adjustable from straight
stream to full fog with a flow of 700 GPM @100 PSI. Brass construction
with stainless steel trim. 1% or 3% proportioning. Nozzle is supplied with
a 1” x 8 ft. flexible pick-up hose. Foam is proportioned directly from an
atmospheric storage tank.

Model # Flow Range @100psi Water Concentrate K-factor Proportioning


Hydro-Foam™ @100psi (straight stream) inlet inlet
Nozzle
Medium Body 700 gpm 160 ft. 2.5”NH 1”NPT(M) 70 1% or 3%
LW700 (F)swivel

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D21
www.williamsfire.com

Hydro-Foam™ Nozzles
nozzles

nozzles
Product:
Hydro-Foam™ Monitor Nozzles Medium Body LWNS 350, 500 & 750

Description:
Patented water powered nozzle system that proportions and delivers either
water or foam to the hazard area. Fully adjustable from straight stream to
full fog. Brass construction with stainless steel trim. Flows 350, 500 or 750
gpm @100 psi, with 1% or 3% (6% @ 350 and 500 gpm) proportioning. An
optional 1% / 3% (3% / 6% @ 350 and 500 gpm) selector valve provides dual
proportioning. Foam concentrate is proportioned directly from an atmospheric
storage tank or from a remote foam concentrate supply in conjunction with a
matched Jet Ratio Controller at 1% or 3% only. Nozzle is supplied with 1.5”
X 8 ft. flexible pick-up hose.

Model LWNS 350 LWNS 500 LWNS 750


Hydro-Foam™ Nozzle
Nominal Flow @100psi 350 gpm 500 gpm 750 gpm
Nominal Range @ 100psi 135 ft. 150 ft. 160 ft.
(straight stream)
Water Inlet 2.5”NH (F) Swivel 2.5”NH (F) Swivel 2.5”NH (F) Swivel
Foam Concentrate Inlet 1.5” NPT(M) 1.5” NPT(M) 1.5” NPT(M)
Proportioning 1% / 3% / 6% 1% / 3% / 6% 1% / 3%

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D22
www.williamsfire.com

Handline Nozzles
nozzles

nozzles
Product:
HYDROJET HANDLINE NOZZLES
Viper Select Series

Description:
Superior quality fire fighting handline nozzles. Created from performance data gained through extensive research, as well
as from actual field exposure on a multitude of large “fires in anger.”

• Multiple Gallonage/Constant Flow design.


• Compact and Lightweight Design in Extruded “E-Lite” Alloy.
• Molded Composite Rubber Pistol Grip for Precise Control.
• Durable Construction Provides Superior Impact Resistance.

Standard Features Include:


» Constant Flow feature Allows for use with Matched Foam Eductor.
» Factory Installed spinning teeth for Maximum Stream Break-up.
» Combination Full Fog to Straight Stream.
» Independent Pattern Selection with Indication.
» Heavy Duty Rubber Bumper.
» Fully Machined Waterway for Flow Efficiency.
» Excellent for use with ThunderStorm® ATC Foam Concentrates.
» Horseshoe Shutoff Provides Positive Flow Control.
» Change Flow without Changing Pattern.
» Full Flush Feature.

Model Nominal Flow Inlet Length Weight


HydroJet Nozzle

SG-3012 30,60,95,125 1.5” NH (F) 8.9” 4.25 lbs.


SG-7515 75,100,125,150 1.5” NH (F) 8.9” 4.25 lbs.
SG-9520 95,125,150,200 1.5” NH (F) 10.6” 6.5 lbs.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D23
www.williamsfire.com

Handline Nozzles
nozzles

nozzles
Product:
HYDROJET HANDLINE NOZZLES
Viper Select Series

Standard Viper Nozzle


SG-3012
SG-7515

Viper Midrange Nozzle


SG-9520

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D24
www.williamsfire.com

Air Aspirating Foam Nozzle


Model AFN-1
nozzles

nozzles
General Description Ordering Information
Constructed of hard anodized aluminum with stainless steel fasteners Part No. Description
and adjustment rod, this air aspirating foam nozzle offers minimum weight 400200 AFN-1 Nozzle
with durability. Stream pattern is adjustable in the field from an even fan type 400336 AFN-1M Nozzle with Lever Operator
to a full straight stream. 400380 AFN-1-SS Stainless Steel Nozzle
Flow rates are specifically tailored to individual protection by the inser- 400326 AFN-1M-SS Stainless Steel
tion of a pre-engineered stainless steel orifice plate.
Orifice plates can be sized for flows from 250 to 1000 gpm (946 to
3785 Lpm) within K-factors of 35 to 125 based on flowing nozzle inlet pres-
sure. (Monitor friction loss must be deducted from monitor inlet pressure to
use those K-factors.)
Connector is a female swivel, 2.5” – 7.5” TPI NHT.

AFN-1 Nozzle
48.125“
(122.2 cm)

2.5“ - 7.5 NHT 4.5” (11.4 cm) Adjustable Control


Swivel Coupling Diameter Rod Adjustable Jaws

AFN-1 Nozzle
48.125“
(122.2 cm)

Lever Operator
Control Rod

2.5“ - 7.5 NHT 4.5” (11.4 cm)


Swivel Coupling Diameter Adjustable Jaws

Nozzle Flow and Range


Range at Range at Range at Range at
Pressure Flow Rate 30° Elev. 22.5° Elev. 15° Elev. 0° Elev.
psi (kPa) gpm (Lpm) ft. (m) ft. (m) ft. (m) ft. (m)
_________ __________ ________ ________ ________ ________
  50   (345) 385 (1457) 135 (41) 135 (41) 115 (35)   50 (15)
100   (690) 534 (2021) 175 (53) 175 (53) 170 (52)   80 (24)
150 (1034) 656 (2483) 190 (58) 190 (58) 190 (58) 100 (30)

NOTE:  Above based on orifice sized for 500 gpm @ 100 psi (1893 Lpm @ 690 kPa).

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D25
www.williamsfire.com

Air Aspirating Foam Nozzle


Model AFN-2
nozzles

nozzles
General Description Ordering Information
Constructed of hard anodized aluminum with stainless Part No. Description
steel fasteners, adjustment rod and deflector; this air aspi- 77088 AFN-2 Nozzle
77115 AFN-2M Nozzle with Lever Operator
rating foam nozzle offers minimum weight with durability.
Stream pattern is adjustable in the field to a dispersed stream
or a full straight stream.
Flow rates are specifically tailored to individual
protection by the insertion of a pre-engineered stain-
less steel orifice plate. Orifice plates can be sized for
flows from 700 to 2000 gpm (2650 to 7571 Lpm) within
K-factors of 57 to 233 based on flowing nozzle inlet pressure.
(Monitor friction loss must be deducted from monitor inlet
pressure to use these K-factors.)

AFN-2 Nozzle
51.5“
(130.8 cm)

6.5” (16.5 cm)


Adjustable Stream Deflector
Flange Connection Diameter
Control Rod

AFN-2M Nozzle
51.5“
(130.8 cm)

Lever Operator Splash Guard

6.5” (16.5 cm) Stream Deflector


Flange Connection Diameter Control Rod

Nozzle Flow and Range


Range at Range at Range at
Pressure Flow Rate 22.5° Elevation 15° Elevation 7° Elevation
psi (kPa) gpm (Lpm) ft. (m) ft. (m) ft. (m)

  50   (345)   722 (2733) 100 (30)   80 (24)   60 (18)


100   (690) 1053 (3986) 160 (49) 140 (43) 120 (37)
150 (1034) 1265 (4789) 200 (61) 180 (55) 160 (49)
NOTE:  Above based on orifice sized for 1000 gpm @ 100 psi (3785 Lpm @ 690 kPa).

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D26
www.williamsfire.com

Air Aspirating Handline Nozzles


nozzles

nozzles
Features 23.1”

• Stainless Steel Construction for Use in (58.7 cm)


19”
Corrosive Environments (48.3 cm)

• Nominal Flow Rates of 60, 95, or 120 gpm


(227, 360, or 454 Lpm) 2.5”
3”
(6.4 cm)
• Compatible with Ansul PL-60, PL-95, and (7.6 cm)

PL-120 Line Proportioners 19”


(48.3 cm) Nozzle
• Optional Pistol-Grip Shutoff Available Optional
(Anodized Aluminum) Shutoff

• Lightweight, Portable Design for Maximum


Mobility

Application
Ansul (HL) foam handline nozzles can be used with all low expansion foam agents: protein foam, fluoroprotein foam,
and AFFF. These portable, air aspirating nozzles can be used in a variety of flammable liquid hazard areas. Typical applica-
tions include use by municipal fire departments and crash-fire-rescue vehicles; or for handline applications around tank farms,
loading racks, aircraft hangars, and chemical plants.

Description
Ansul handline nozzles are available in three sizes (HL-60, HL-95, and HL-120) with or without pistol-grip shutoff. The
nozzles are constructed of stainless steel; the pistol-grip shutoff is anodized aluminum. Lightweight and compact, they maxi-
mize fire fighting mobility and ease of use.

Typical Foam Quality/Range Data Hose Length/Size Data


Protein/ Maximum
Fluoro- Hose Hose
protein
______ AFFF
____ 3% ARC
_______ Handline Line Size Length*
Nozzle
_____ Proportioner
__________ in.
____ ft. (m)
________
Foam 8:1 10:1 7:1
Expansion HL-60 PL-60 1.5” 200 (61.0)
Ratio HL-95 PL-95 1.5” 100 (30.5)
Drain Time 7 min. 3 min. 8 min. HL-120 PL-120 1.5” 100 (30.5)
(25%) * Maximum hose length is based on nozzle being elevated a maximum of 8 ft. (2.4 m) above line proportioner.
Stream Range 50 ft. 50 ft. 50 ft.
@ 50 psi (15.2 m) (15.2 m) (15.2 m)
   (345 kPa)
Stream Range 65 ft. 65 ft. 65 ft.
@ 75 psi (19.8 m) (19.8 m) (19.8 m)
   (517 kPa)
Stream Range 75 ft. 75 ft. 75 ft.
@ 100 psi (22.9 m) (22.9 m) (22.9 m)
   (690 kPa)

Ordering Information
The models listed below are provided with 1.5” NHT female inlet threads. Other thread types are available upon request.
The flow rates listed are nominal; see Flow Rate Data for actual flow rates based on inlet pressure.

Approx Approx Approx


Shipping Shipping Shipping
Part Weight Part Weight Part Weight
No. Description lb. (kg) No. Description lb. (kg) No. Description lb. (kg)

77796* HL-60 Nozzle 5 (2.3) 77797* HL-95 Nozzle 5 (2.3) 77981 HL-120 Nozzle 5 (2.3)
without Shutoff, without Shutoff, without Shutoff,
60 gpm (227 Lpm) 95 gpm (360 Lpm) 120 gpm (454 Lpm)

77792* HL-60S Nozzle 7 (3.2) 77793* HL-95S Nozzle 7 (3.2) 78419 HL-120S Nozzle 7 (3.2)
with Shutoff, with Shutoff, with Shutoff,
60 gpm (227 Lpm) 95 gpm (360 Lpm)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D27
www.williamsfire.com

Air Aspirating Handline Nozzles


nozzles

nozzles
Flow Rate Data
____
(kPa) ___
psi
HL-60 HL-95 HL-120
(1034) 150

(827) 120

(690) 100
Inlet Pressure

(621) 90

(552) 80

(483) 70

(414) 60

(345) 50

(276) 40
40 50 60 70 80 90 100 120 150 gpm
(151) (189) (227) (265) (303) (341) (379) (454) (568) (Lpm)
FLOW RATE
001224

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D28
www.williamsfire.com

Foam Nozzles
nozzles

nozzles
Product:
Foam Wand

Description:
The Foam “Wand” is designed to expand and deliver foam into remote/
hazardous areas where either logistics or safety considerations dictate that
the foam nozzle be “unattended.” The “wand” delivers high quality foam
onto hard-to-access flammable liquid fires. Flow rate is 95 gpm @ 100
psi (K=9.5). Works in conjunction with a standard 95 gpm inline educ-
tor or other foam proportioning system. Nominal foam expansion is 4:
1. Assembly includes 1.5” NH (F) brass swivel
foam solution inlet; carbon steel distribution pip-
ing; foam nozzle; detachable horizontal “stand-
off”, canvas carrying case.

Typical Application
Foam Wand assembly

Model Nominal Flow K-factor Inlet Body


Foam Wand @ 100 PSI
95 gpm 95 gpm 9.5 1.5” NH(F) Swivel Schedule 40
Carbon Steel

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
D29
www.williamsfire.com

MONITOR
monitors

monitors
SECTION INDEX

Daspit Tool™.........................................................................................................................................................................................E2

Daspit Tool - Truck Mount™..........................................................................................................................................................E3

Daspit Tool™ - Throw Down Model............................................................................................................................................E4

Alpha MA-HV4 - 4” Aluminum Tiller Bar Monitor...............................................................................................................E5

Alpha-E Tiller Bar Montior - 3”................................................................................................................................................E6

“SharpShooter Four” Tiller Bar -4”..............................................................................................................................................E7

“SharpShooter Four” Dual Handwheel -4”.............................................................................................................................E8

Alpha-SHW Single HandWheel Monitor - 3”....................................................................................................................E9

Spectrum “Mini- Monitor” - 2”....................................................................................................................................................E10

Spectrum High Flow Model 4 Oscillating Monitor / Tiller Bar Control.................................................................E11

Spectrum Medium Flow Model 4 Oscillating Monitor...................................................................................................E12

Spectrum Marine Grade Model 4 Oscillating Monitor..................................................................................................E13

Spectrum Low Flow Model 4 Oscillating Monitor............................................................................................................E14

“Durham” Oscillating Monitor Conversion Kit .................................................................................................................E15

Spectrum Direct-Mounted Electric Actuated Monitor..........................................................................................E16-E17

Spectrum Electro/Hydraulic Actuated Monitors....................................................................................................E18-E19

Monitor & Friction Head Loss Chart.......................................................................................................................................E20

Hydrant Monitor Stand...................................................................................................................................................................E21

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E1
www.williamsfire.com

Monitors
monitors

monitors
Product:
Daspit Tool™

Features:
Patented “Daspit Tool” tank frame clamp with 5” vertical waterway
“Daspit Tool” Specialty Flange Monitor Adapter
“Daspit Tool” Rotator Elbow with Storz inlet and 4.5” (F) NH swivel adapter

Component Weights:
Daspit Tool™ Tank Clamp = 89 lbs

Accessory Component Weights:


90˚ Aluminum Rotator Elbow - 4.5” (F) NH Swivel x 5” Storz = 22 lbs 30˚ Aluminum Rotator Elbow - 4.5” (F) NH
Swivel Elbow x 5” Storz = 9 lbs
4” Aluminum Tiller Bar Monitor w/ 4.5” (F) NH Swivel inlet = 43 lbs
4” Aluminum Dual Hand Wheel Monitor - 4.5” (F) NH Swivel inlet = 50 lbs
Ranger™ 1.5 Nozzle = 22 lbs

Applications:
Sunken roof
Rim Seal fire
Vapor Suppression/Mitigation

Options:
3” Aluminum Waterway Monitor w/Tiller Bar Control
250-1,000 gpm Automatic Nozzle
4” Aluminum Waterway Monitor w/Dual Hand Wheel Control
500-2,000 gpm Automatic Nozzle
Rim Mounted Model
Truck Mounted Model
“Throw-Down” Model
Tank Mount Standard Unit

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E2
www.williamsfire.com

Monitors
monitors

monitors
Product:
Daspit Tool - Truck Mount™

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E3
www.williamsfire.com

Monitors
monitors

monitors
Product:
Daspit Tool™ - Throw Down Model

Component Weights:
Daspit™ Tool Throw Down Mount = 113 lbs
8 Stabilizing stakes = 64 lbs

47.875”

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E4
www.williamsfire.com

Monitors
monitors

monitors
Product:
Alpha MA-HV4 Monitor

Description:
Rugged lightweight aluminum construction 4” ID full flow monitor with “Quick Acting” Tiller-Bar control for vertical
and horizontal movement. Red powder coat anodized aluminum. The single 4” full-flow waterway with internal turning vanes
is designed to provide maximum efficiency. The “Easy-Lock” brake system insures that the nozzle position “stays put” with
the simple twist of an ergonomically designed locking bar. Monitor features a 3.50” (M) NH outlet and a 4.0” 150# ASA
flat-faced flange inlet. Horizontal articulation is 360˚ and vertical travel is 75˚ up and -25˚ down.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E5
www.williamsfire.com

Monitors
monitors

monitors
Product:
Alpha-E Tiller Bar Montior - 3”

Description:
Rugged, corrosion resistant brass construction; unique configuration flows up to 1250 gpm; compact - just 16” high; 3”
NPT female, 3” or 4” 150# ANSI flange; vertical movement 90 degrees above horizontal to 45 degrees below; full, continuous
360 degree rotation; rugged, stainless steel lock hardware; brass balls in all swivel joints; grease fittings for easy lubricaion;
durable acrylic urethane finish

Horizontal
Waterway Inlet Discharge Material Vertical Travel
Alpha-E Tiller Bar Rotation
Monitor
3” 3”-4” Flanged 2.5” NH(M) Cast Brass 90º 360º

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E6
www.williamsfire.com

Monitors
monitors

monitors
Product:
“SharpShooter Four” Tiller Bar -4”

Description:
Superior grade 4” I.D. waterway monitor with tiller bar
control for vertical and horizontal movement. Designed for
use in corrosive atmospheres that require the dependability
and durability of an all brass monitor. Single waterway
with turning vanes providing excellent projection for water
or foam streams. Flows up to 1,500 gpm.

Tiller bar control with brake band swivels, adjusts, then


locks at the vertical and horizontal position. Vertical setting
is from minus (-) 10º to plus (+)70º. Full 360 degree hori-
zontal travel. Painted red polyurethane finish. 3.5”NH (M)
discharge threads. Base -4” 150 # ASA flange.

Horizontal
Waterway Inlet Discharge Material Vertical Travel
Sharpshooter Rotation
Four
4” 4” Flange 3.5” NH(M) Cast Brass 80º 360º

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E7
www.williamsfire.com

Monitors
monitors

monitors
Product:
“SharpShooter Four” Dual Handwheel -4”

Description:
Superior grade 4” I.D. waterway monitor with dual handwheel/worm
gear operation for vertical and horizontal movement. The ultimate monitor
for portable applications or for fixed installations where precise and posi-
tive control are needed. Designed for use in corrosive atmospheres that
require the dependability and durability of an all brass monitor. Single
waterway with turning vanes providing excellent projection for water or
foam streams. Flows up to 1,500 gpm.

Vertical handwheel adjusts trajectory from minus (-) 10º to plus (+)90º.
Horizontal handwheel allows for full 360º rotation. Painted red polyure-
thane. 3.5”NH (M) discharge threads. Base -4” 150 # ASA flange.

Horizontal
Waterway Inlet Discharge Material Vertical Travel
Sharpshooter Rotation
Four 3.5” NH(M)
4” 4” Flange Cast Brass 100º 360º
Flange

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E8
www.williamsfire.com

Monitors
monitors

monitors
Product:
Alpha-SHW Single HandWheel Monitor - 3”

Description:
Rugged, cast brass construction • Full 3.0” unobstructed waterway • FLows up to 1250 GPM • Handwheel driven worm
gear fully enclosed and protected from the elements • Stainless steel worm • Vertical travel from 70˚ above to 70˚ below
horizontal • Gear holds vertical position wherever it is stopped • Four ball races with bronze balls and grease zerks for easy
lubrication • Full 360˚ rotation with positive twist lock • 2.5” male outlet • FM Approved • See chart for base options • Finish
red urethene enamel.

Horizontal
Model Waterway Inlet Discharge Material Vertical Travel
Rotation

Alpha-SHW 3” 3” or 4” Flange 2.5” NH(M) Cast Brass 90º 360º

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E9
www.williamsfire.com

Monitors
monitors

monitors
Product:
Spectrum “Mini- Monitor” -2”

Description:
Designed for use in corrosive atmospheres that require the
dependability of an all brass monitor. Suitable for most industrial
environments. Flows up to 300 gpm @ 100 psi. Full 2” I.D. water-
way, efficiently designed to minimize pressure drop. 2” NPT female
inlet base, 1.5” NH male discharge tip. Tiller bar control handle with
rubber grip. Vertical (110º) and horizontal (360º) adjustments with
positive quarter-turn locking handles. Natural brass finish.

Horizontal
Model Waterway Inlet Discharge Material Vertical Travel
Rotation

Mini Monitor 2” 2”NPT (F) 1.5” NH(M) Cast Brass 110º 360º

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E10
www.williamsfire.com

Oscillating Monitors
monitors

monitors
Product:
Spectrum High Flow Model 4 Oscillating Monitor Tiller Bar Control

Description:
For flows between 750 - 1500 gpm. Spectrum High Flow Model
4 water-powered oscillating monitor is constructed of predominantly
corrosion-resistant materials. Cast brass monitor body with stain-
less steel trim. 4” I.D. waterway with turning vanes. Controls pro-
vided for adjusting vertical trajectory as well as horizontal position.
Reciprocating motion is generated by a two-way high performance
hydraulic actuator. Oscillation is accomplished through the use of
plated sprockets and a heavy duty drive chain. Standard arc of oscil-
lation is from 0-90˚ and speed of oscillation is from 0-40˚ per second.
Vertical trajectory is from minus (-)10˚ to plus (+)70˚. Standard inlet
flange - 4” 150# ASA RF Flange. Monitor is to be used with either
a non air-aspirating or air-aspirating nozzle. Standard 3.5” NH (M)
discharge. Oscillating mechanism is Factory Mutual Approved - File (Nozzle shown for
No. J.I.1R6A3.AF. reference only)

Model Flow @ 100 PSI Inlet Discharge Water I.D.

High Flow Model 4 Between 750-1400 gpm 4” 150# ASA RF flange 3.5” NH (M) 4”
Tiller Bar Control

* Minimum operating pressure = 50 psi

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E11
www.williamsfire.com

Oscillating Monitors
monitors

monitors
Product:
Spectrum Medium Flow Model 4
Oscillating Monitor

Description:
For flows between 150-750 gpm. Spectrum Medium Flow
Model 4 low profile water-powered oscillating monitor features a
super-compact design, as well as predominantly corrosion resistant
materials of construction. Reciprocating motion is generated by a
two way high performance hydraulic actuator. Oscillation is accom-
plished through the use of plated sprockets and a heavy duty drive
chain. Arc of oscillation is from 0-185º and speed of oscillation is
from 0-40º per second. Nozzle elevation is from 10º below to 70º
above horizontal. Single brass 3” I.D. waterway with turning vanes (Nozzle shown for
provided with positive horizontal and vertical locks. Standard inlet reference only)

flange - 4” 150# ASA RF Flange. Monitor can be used with either a


non air-aspirating or air aspirating nozzle. Oscillating mechanism is
Factory Mutual Approved - File No. J.I.1R6A3.AF.

Model Flow @ 100 PSI Inlet Discharge Water I.D.

Medium Flow Model 4 Between 150-750 gpm 4” 150# ASA RF flange 2.5” NH (M) 3”

* Minimum operating pressure = 50 psi


01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E12
www.williamsfire.com

Oscillating Monitors
job list

job list
Product:
Spectrum Marine Grade Model 4
Oscillating Monitor

Description:
For flows between 150-750 gpm. Spectrum Marine Grade Model 4 low profile water-powered oscillating monitor fea-
tures a super-compact design, as well as construction of totally corrosion resistant materials to include inlet flange, enclosure
and drive mechanism, sprocket and chain — all manufactured in 316 Stainless Steel. Reciprocating motion is generated by a
two way high performance hydraulic actuator. Oscillation is accomplished through the use of plated sprockets and a heavy
duty drive chain. Arc of oscillation is from 0-185º and speed of oscillation is from 0-40º per second. Nozzle elevation is from
10º below to 70º above horizontal. Single brass 3” I.D. waterway with turning vanes provided with positive horizontal and
vertical locks. Standard inlet flange - 4” 150# ASA RF Flange. Monitor can be used with either a non air-aspirating or air
aspirating nozzle. Oscillating mechanism is Factory Mutual Approved - File No. J.I.1R6A3.AF.

Model Flow @ 100 PSI Inlet Discharge Water I.D.

Marine Grade Between 150-750 gpm 4” 150# ASA RF flange 2.5” NH (M) 3”
Model 4

* Minimum operating pressure = 50 psi


01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E13
www.williamsfire.com

Oscillating Monitors
monitors

monitors
Product:
Spectrum Low Flow Model 4 Oscillating Monitor

Description:
For flows between 100-350 gpm. Spectrum Low Flow Model 4 low
profile water-powered oscillating monitor features a super-compact design,
as well as corrosion resistant materials of construction. Reciprocating
motion is generated by a two-way high performance hydraulic actuator.
Oscillation is accomplished through the use of plated sprockets and a heavy
duty drive chain. Arc of oscillation is from 0-185º and speed of oscillation
is from 0-40º per second. Nozzle elevation is from 30º below to 80º above
horizontal. Single brass 2” I.D. waterway. Provided with positive horizontal
and vertical locks. Standard inlet flange -4” 150#. Monitor can be used with
either a non air-aspirating or air-aspirating nozzle. Oscillating mechanism is
Factory Mutual Approved - File No. J.I.1R6A3.AF.

(Nozzle shown for


reference only)

Model Flow @ 100 PSI Inlet Discharge Water I.D.

Low Flow Model 4 Between 100 - 350 gpm 4” 150# ASA RF flange 1.5” NH(M) 2”

* Minimum operating pressure = 50 psi

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E14
www.williamsfire.com

Oscillating Monitors
monitors

monitors
Product:
“Durham” Oscillating Monitor Conversion Kit

Description:
The Durham Conversion Kit transforms an existing manual sta-
tion monitor into an oscillator. Designed for use with most 2.5” or 3”
I.D. single waterway monitors, flowing up to 750 gpm. Upgrading
foam or water monitor coverage in any area is now as easy as unbolt-
ing the existing monitor and inserting the conversion kit between
the flanges. Oscillating mechanism is identical to the one used on
the Spectrum Model 4 Oscillating Monitor and is Factory Mutual
Approved - File No. J.I.1R6A3.AF. Standard inlet and discharge
flange is -4” ASA RF Flange 150#. Optional inlet and discharge
flanges available upon request.

Model Flow @ 100 PSI Inlet Discharge Water I.D.


Durham
up to 750 gpm 4” 150# ASA RF flange 4” 150# ASA RF flange 2.5” or 3”
Conversion Kit

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E15
www.williamsfire.com

Remote Control Monitors


monitors

monitors
Product:
Spectrum Direct-Mounted Electric Actuated Monitor

Description:
Flows water or foam from 500 to 6,000 gpm. The Spectrum Direct-Mounted
Electric Actuated High Volume/Remote Control Monitor has a programmable
oscillation capability, but may also be overridden with a matched Hydro-Foam™
nozzle operated remotely through the use of a joystick and switches on a consoli-
dated control panel. Manual operation can also be accomplished locally through
the use of handwheels. Foam concentrate can be proportioned at the nozzle
through the use of a jet ratio controller and atmospheric concentrate storage tank.
All electric actuators are reversible, NEMA 7 explosion proof, refinery grade,
F.M. Approved and C.S.A. certified. No external controls, starters, or starters in
motor control center are needed. Only power and control conductors are required.
Monitor can be programmed to “return to home” position (horizontal, vertical,
nozzle to wide angle fog) after use, automatically, whether P.L.C. controlled or
hard wired.

Two direct mounted electric actuators with speed reducing gear drives installed on the motor enable remote control of
horizontal position, as well as vertical trajectory. Field-adjustable limit switches on each actuator allow 340º horizontal rota-
tion and from minus (-)70º to plus (+)70º vertical travel. Monitor traversing speed is a least 10º per second. A third direct-
mounted electric actuator enables remote operation for the nozzle’s discharge pattern, from wide fog to straight stream.

Weather protective cowlings are provided over all gears and shafts. Monitor and controls are designed for minus
(-)20º F operation. Maximum working pressure is 200 psi.

Stainless Steel monitor (waterway) with red epoxy finish. Includes lifting lug for handling and mounting. Stainless steel
swivels with stainless steel ball bearings. Steel/bronze gears. Nickel plated brass shaft. Standard motor voltage is 480/3/60.
Standard Control voltages is 120 Vac. Other voltages are available when required.

Model Nominal flow range Inlet Pressure Drop


4” Waterway Monitor 500-1500 gpm 4” flange @ 1500 gpm-9 psi
6” Waterway Monitor 1500-3000 gpm 6” flange @ 3000 gpm-7 psi
8” Waterway Monitor 2500-6000 gpm 8” flange @ 6000 gpm-10 psi

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E16
www.williamsfire.com

Remote Control Monitors


monitors

monitors
Spectrum Direct-Mounted
Electric Actuated Monitor

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E17
www.williamsfire.com

Remote Control Monitors


monitors

monitors
Product:
Spectrum Electro/Hydraulic Actuated Monitors

Description:
Flows water or foam from 500 to 3,000 gpm. The Spectrum Electro/
Hydraulic High Volume/Remote Control Monitor is operated remotely through
the use of a joystick and switches on a consolidated control panel. Manual opera-
tion can also be accomplished locally through the use of handwheels.

Two hydraulic actuators installed on the monitor enable remote control of


horizontal position, as well as vertical trajectory. Maximum travel is limited to
340 degrees horizontal travel and from minus (-)70 degree to plus (+)70 degree
vertical travel. Monitor traversing speed is at least 8 degrees per second. A
direct-mounted linear hydraulic actuator enables remote operation for the
nozzle’s discharge pattern, from wide fog to straight stream. Weather protective
cowlings are provided over all gears and shafts.

Equipped with a standard non air aspirating fog-to-straight stream nozzle.


With a matched Hydro-Foam™ nozzle, foam concentrate can be proportioned at
the nozzle through the use of a jet ratio controller and atmospheric concentrate
storage tank.

Stainless steel monitor (waterway) with red epoxy finish. Includes lifting
lug for handling and mounting. Stainless steel swivels with stainless steel ball
bearings. Steel/bronze gears. Nickel plated brass shaft. Anodized aluminum
fog/straight stream nozzle.

Nominal flow range


Model Inlet Pressure Drop
@ 100 psi
4” Waterway Monitor 500-1500 gpm 4” flange @ 1500 gpm-9 psi
6” Waterway Monitor 1500-3000 gpm 6” flange @ 3000 gpm-7 psi

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E18
www.williamsfire.com

Remote Control Monitors


monitors

monitors
Spectrum Electro/Hydraulic
Actuated Monitor

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E19
www.williamsfire.com

Monitor and Friction Head Loss


monitors

monitors
Pressure Loss at Indicated Flow

24
23
22
21
20 4”
3”
19
18
17
16
15
14
P 13
S 12
I 11
G 10
9
6”
8
7 2”
6
8”
5
4
3
2
1
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
U.S. GPM

Note: Pressure losses indicated are nominal and vary slightly with each monitor.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E20
www.williamsfire.com

Monitor Accessories
monitors

monitors
Product:
Hydrant Monitor Stand

Description:
For mounting monitor station (Hydro-Foam™ or water only)
onto any fire hydrant. Standard configuration: water inlet is 2.5”
NH(F) brass swivel; 3” waterway with 90 degree elbow; bolted ver-
tical support stanchions; flanged discharge (specify either 3” or 4”
150# ASA). Red polyurethane finish.

Monitor Stand shown with Hydrant and Optional


Monitor and Nozzle.
Note: hydrant not included.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
E21
www.williamsfire.com

MONITOR / NOZZLE PACKAGES

monitor / nozzle packages


monitor / nozzle packages

SECTION INDEX

Foam Application Method........................................................................................................................................................F2-F4

FootPrint™ Methodology......................................................................................................................................................... F5-F6

Minimum Firewater Requirements for Foam Application - Full Surface Protection.......................................F7

Minimum Firewater Requirements for Foam Application - 1% Foam Concentrate.........................................F8

Minimum Firewater Requirements for Foam Application - 3% Foam Concentrate.......................................F9

“Big Foot” Trailer Mount 4,000 - 14,000 GPM.............................................................................................................F10-F12

Battler 2 x 10 Monitor / Nozzle....................................................................................................................................................F13

Ambassador 1 x 6 Monitor/Nozzle............................................................................................................................................F14

Ranger3™ ............................................................................................................................................................................................F15

Hired Gun Trailer - 2000 GPM.....................................................................................................................................................F16

Hired Gun Layout................................................................................................................................................................................F17

Patriot Ranger3™/ “Quick Action” Deck Gun, 1000-3000 GPM................................................................................F18

Gear Operated 6” Monitor............................................................................................................................................................F19

Patriot 1- “Worm Gear” Deck Gun, 1000 GPM..................................................................................................................... F20

1.5 HC Ranger™ 250-1500 Deck Gun......................................................................................................................................F21

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F1
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

Foam Application Method: High Volume Foam Application


(Design Reference NFPA 11)

General -
High Volume Foam Monitors (fixed or transportable) are effective tools for protecting storage tanks containing flam-
mable or combustible liquids. Foam monitors can be considered as the primary means of fire suppression for full service foam
application onto open floating roof storage tanks, or onto “fixed roof” tanks of up to 60 ft. in diameter. For fixed roof storage
tanks greater than 60 ft. diameter, foam monitors can be considered as a viable backup system, to be used in the event that the
primary foam fire protection system is rendered inoperable or unavailable.

Cone Roof Tank Covered Floating Open Floating


Roof Tank Roof Tank

Minimum Foam Application Rates -


Stated minimum foam application rates are based on the assumption that all foam reaches the interior of the tank, or “land-
ing zone”. Also, these minimum rates are for tanks 180 ft. in diameter or less. For tanks greater than 180 ft. diameter, consult
with your Williams Fire & Hazard Control, Inc® representative for current data regarding recommendations for minimum
ThunderStorm® foam application rates on specific fuels.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F2
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

High Volume Foam Monitors

Design Considerations

Minimum Application Densities

To use the chart, first look up the liquid’s flash


point and its water solubility. Determine their point
of intersection and zone on the chart. Then refer to
the data below to determine the minimum application
density. Examples of common flammable liquids are
listed in each category. Flash point and solubility
data on additional flammable liquids can be found
in the NFPA Hazardous Materials Handbook and in
other similar sources.

Type of Fuel Foam Minimum Application


Density, gpm/ft2
Hydrocarbons - Category A

Combustible Liquids F-601A ATC @ 1% 0.16


(flash point <100˚ F)
Flammable Liquids F-601A ATC @ 1% 0.16
(flash point >100˚ F)
Crude Petroleum F-601A ATC @ 1% 0.16

Gasohol F-601A ATC @ 1% 0.16

Water Miscibles - Category B,C,D


(Alcohols)
Category B F-601A ATC @ 3% .13
Category C F-601A ATC @ 3% *.13
Category D F-601A ATC @ 3% *.13

* Contact Williams Fire & Hazard Control, Inc® for recommendations regarding application densities for specific
fuels — Telephone 409-727-2347

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F3
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

High Volume Foam Monitors

Design Considerations

Determining Water/Foam Requirments


Calculating the area of a circle: πr2 = ft2

FT2 x *Application Rate = GPM Water/Foam Solution


GPM Water/Foam Sol. x % Concentrate = GPM Foam Concentrate.
GPM Foam Concentrate x Recommended Duration (NFPA 11) = Total Gallons of Concentrate required
on scene

*Application Rate per Square Foot


NFPA 11 recommends a minimum 0.16 gpm/ft2 application rate for Type III.
Although 0.16 is a minimum much of the industry uses it as a standard.
Williams Fire & Hazard Control recognizes as the tank diameter increases, increasing the application rate must be
considered.

Williams’ Recommended Type III Application Rates For Hydrocarbon Storage Tanks

0’ - 150’ 0.16 GPM/Ft2


151’ - 200’ 0.18 GPM/Ft2
201’ - 250’ 0.20 GPM/Ft2
251’ - 300’ 0.22 GPM/Ft2
300’ + 0.25 GPM/Ft2

Example calculation for a 150’ Storage tank:


75 x 75 x 3.14 = 17,662.5 ft2
17,662.5 x .16 = 2,826 gallons per minute required flow
(2,826 GPM would practically be rounded up to 3,000 GPM)
3,000 GPM x .01% concentrate = 30.0 gallons concentrate per minute
30.0 Gal/concentrate for 65 minutes = 1,950 total gallons concentrate required (minimum)
Add 100% for reserve inventory (if required)

Minimum Foam Application Durations

Combustible Liquids (flash point < 100˚ F) = 50 minutes


Flammable Liquids (flash point > 100˚ F) = 65 minutes
Crude Oils = 65 minutes
Alcohols = 65 minutes

Minimum Foam Concentrate Inventories

Calculation for minimum foam inventory is (where D = Tank Diameter):

Minimum Foam Inventory =


(D x D) x 0.785 x (Min Application Density) x (% Proportioning) x (Application Duration)

Example calculation for an 80’ Diameter Tank in Crude Oil Service:


(80 x 80) x 0.785 x 0.16 x .03 x 65 1568 gallons
Add for 100% Reserve Inventory (if required) + 1568 gallons
Total Minimum Foam Inventory 3136 gallons

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F4
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

FootPrint™ Methodology

For US and Foreign Patent and Trademark information, please refer to page PI2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F5
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

FootPrint™ Methodology

US Patents

For use of FootPrint™ methodology,


please contact Williams Fire & Hazard Control, Inc®

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F6
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

Minimum Firewater Requirements for Foam Application -


Full Surface Protection

Tank Minimum Firewater Flow Rates (gpm)* Minimum Firewater Capacities Required
Diam for 65 Minute Application (gallons)**
(Feet)
— Application Densities*** —  — Application Densities*** —

.16 .18 .20 .22 .25 .16 .18 .20 .22 .25
50 315 354 393 432 491 20475 23010 25545 28080 31915
60 453 509 566 622 707 29445 33085 36790 40430 45955
70 616 693 770 847 962 40040 45045 50050 55055 62530
80 804 905 1005 1106 1256 52260 58825 65325 71890 81640
90 1018 1145 1272 1399 1590 66170 74425 82680 90935 103350
100 1256 1413 1570 1727 1963 81640 91845 102050 112255 127595
110 1520 1710 1900 2090 2375 98800 111150 123500 135850 154375
120 1809 2035 2261 2487 2826 117585 132275 146965 161655 183690
130 2123 2389 2654 2919 3317 137995 155285 172510 189735 215605
140 2462 2770 3078 3385 3847 160030 180050 200070 220025 250055
150 3180 3533 3886 4416 206700 229645 252590 287040
160 3618 4020 4422 5024 235170 261300 287430 326560
170 4084 4538 4992 5672 265460 294970 324480 368680
180 4579 5089 5596 6359 297635 330785 363740 413335
190 5101 5668 6235 7085 331565 368420 405275 460525
200 5652 6280 6908 7850 367380 408200 449020 510250
210 6924 7617 8655 450060 495105 562575
220 7599 8359 9499 493935 543335 617435
230 8306 9136 10381 539890 593840 674765
240 9044 9948 11304 587860 646620 734760
250 9813 10794 12266 637845 701610 797290
260 10614 11675 13267 689910 758875 862355
270 11446 12590 14307 743990 818350 929955
280 12309 13540 15386 800085 880100 1000090
290 13204 14525 16505 858260 944125 1072825
300 14130 15543 17663 918450 1010295 1148095

*Does not include additional firewater which may be needed for supplemental/exposure protection or post extinguishment vapor suppression
**For purposes of design, total nominal capacity of firewater reservoir should be sized to support stated flows for a minimum of 5 hours
***Application Densities indicated as gpm/ft2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F7
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

Minimum Requirements for 1% Foam Concentrate -


Full Surface Protection Using High Volume Monitors*

Tank 50 Minutes 65 Minutes


Diam (Flash Point > 100˚ F) (Flash Point < 100˚ F)
(Feet)
— Application Densities ** —  — Application Densities ** —

.16 .18 .20 .22 .25 .16 .18 .20 .22 .25
50 160 180 200 220 250 205 235 260 285 320
60 230 255 285 315 355 295 335 370 405 460
70 310 350 385 425 485 405 455 505 555 630
80 405 455 505 555 630 525 590 655 720 820
90 510 575 640 700 795 665 745 830 910 1035
100 630 710 785 865 985 820 920 1025 1125 1280
110 760 855 950 1045 1190 990 1115 1235 1360 1545
120 905 1020 1135 1245 1415 1180 1325 1470 1620 1840
130 1065 1195 1330 1460 1660 1380 1555 1730 1900 2160
140 1235 1385 1540 1695 1925 1605 1805 2005 2205 2505
150 1590 1770 1945 2210 2070 2300 2530 2875
160 1810 2010 2215 2515 2355 2615 2875 3270
170 2045 2270 2500 2840 2655 2950 3245 3690
180 2290 2545 2800 3180 2980 3310 3610 4135
190 2555 2835 3120 3545 3320 3685 4055 4610
200 2830 3140 3455 3925 3675 4082 4495 5105
210 3465 3810 4330 4505 4955 5630
220 3800 4180 4750 4940 5435 6175
230 4155 4570 5195 5400 5940 6750
240 4525 4975 5655 5880 6470 7350
250 4910 5400 6135 6380 7020 7975
260 5310 5840 6635 6900 7590 8625
270 5725 6295 7155 7440 8185 9300
280 6155 6770 7695 8055 8805 10005
290 6605 7265 8255 8585 9445 10760
300 7065 7775 8835 9185 10105 11485

Formula: (Tank Diameter)2 x 0.785 x Application Density x 0.01 x Duration (in minutes)
Based on NFPA 11, Hydrocarbon Fuels
*Does not include post extinguishment suppression
**Application Densities indicated as gpm/ft2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F8
www.williamsfire.com

Storage Tank Protection

monitor / nozzle packages


monitor / nozzle packages

Minimum Requirements for 3% Foam Concentrate -


Full Surface Protection Using High Volume Monitors*

Tank 50 Minutes 65 Minutes


Diam (Flash Point > 100˚ F) (Flash Point < 100˚ F)
(Feet)
— Application Densities ** —  — Application Densities ** —

.16 .18 .20 .22 .25 .16 .18 .20 .22 .25
50 480 540 600 660 750 615 705 780 855 960
60 690 765 855 945 1065 885 1005 1110 1215 1380
70 930 1050 1155 1275 1455 1215 1365 1515 1665 1830
80 1215 1365 1515 1665 1890 1575 1770 1965 2160 2460
90 1530 1725 1920 2100 2385 1995 2235 2490 2730 3105
100 1890 2130 2355 2595 2955 2460 2760 3075 3375 3840
110 2280 2565 2850 3135 3570 2970 3345 3705 4080 4635
120 2715 3060 3405 3735 4245 3540 3975 4410 4860 5520
130 3195 3585 3990 4380 4980 4140 4665 5190 5700 6480
140 3705 4155 4620 5085 5775 4815 5415 6015 6615 7515
150 4770 5310 5835 6630 6210 6900 7590 8675
160 5430 6030 6645 7545 7065 7845 8625 9810
170 6135 6810 7500 8520 7965 8850 9735 11070
180 6870 7635 8400 9540 8940 9930 10830 12405
190 7665 8505 9360 10635 9960 11055 12165 13830
200 8490 9420 10365 11775 11025 12246 13485 15315
210 10395 11430 12990 13515 14865 16890
220 11400 12540 14250 14820 16305 18525
230 12465 13710 15585 16200 17820 20250
240 13575 14925 16965 17650 19410 22050
250 14730 16200 18405 19140 21048 23925
260 15930 17520 19905 20700 22770 25875
270 17175 18885 21465 22320 24555 27900
280 18465 20310 23085 24165 26415 30015
290 19815 21795 24765 25755 28322 32184
300 21195 23325 26505 27555 30315 34455

Formula: (Tank Diameter)2 x 0.785 x Application Density x 0.03 x Duration (in minutes)
Based on NFPA 11, Hydrocarbon Fuels
*Does not include post extinguishment suppression
**Application Densities indicated as gpm/ft2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F9
www.williamsfire.com

Monitor / Nozzle Packages

monitor / nozzle packages


monitor / nozzle packages

Product Detail:
“Big Foot” Trailer Mount 4,000 - 14,000 GPM
The Williams “Big Foot “ Multi-Flow High-Volume Monitor is
designed for the extinguishment of massive petrochemical fires. The
nozzle is constructed of all corrosion resistant materials, such as anod-
ized aluminum, stainless steel, and composite plastics, and is capable
of flows ranging from 4,000 - 14,000 GPM. The nozzle is available
with six separate stems in increments of 2,000 GPM each. The nozzle
is the self educting type, incorporating patented Hydro-Foam™ tech-
nology. Foam concentrate is supplied via remote jet ratio controllers,
or foam solution can be delivered from an independent proportioning
system directly to the water inlets. The nozzle is constant flow, with
straight stream to full fog capabilities.

The trailer meets all applicable DOT regulations and is constructed of deep channel carbon steel. Ballast tanks are an
integral part of the trailer, providing stability and traction to counteract nozzle reaction forces. The internal water inlet mani-
fold is constructed of 10” I.D. stainless steel. Eight (8) ea., 5” storz (6” optional) inlet connections with caps are provided
for water-foam solution supply. The full system capacity of 14,000 gpm requires a total of ten (10) 5” storz inlets. Each
connection is protected from back flow using a six inch (6”) full flow wafer check valve. Two (2) ea., 4” inlets are provided
(one each side) for foam concentrate supply. The tandem axle trailer has a gross vehicle weight rating (GVWR) of 14,000 lbs.
Mechanical/hydraulic surge brakes are activated via a heavy duty coupler terminating in a pintle hook connection. The tongue
is connected rigidly to the trailer using an A-frame arrangement for maximum stability. Non-skid designed upper decking.
Stabilizing jacks are provided at four points, providing maximum stability.

An operators panel is located aft of the nozzle. The elevated operating position provides a full view of fire ground opera-
tions. All controls are manual gear operated and utilize state-of-the-art hydraulic systems to control vertical travel (+15º to
+45º), horizontal traverse (from 15º right/left of center), and nozzle fog/straight stream pattern.

Standard Trim and Accessories:


• 2 ea.- Concentrate “Jumper” Hose 4” x 10 ft. coupled storz
• 4 ea.- Jet Ratio Controllers 2.0 JP60
• 4 ea.- Drum Kits for Jet Ratio Controllers
• 1 ea.- Jet pump selection chart
• 1 ea.- nozzle flow chart
• 1 ea.- 4000 GPM stem
• 1 ea.- 6000 GPM stem Big Foot- Trailer Mount
• 1 ea.- 8000 GPM stem
• 1 ea.- 10,000 GPM upgrade option Nominal Flow @ 100 PSI
• 1 ea.-12,000 GPM upgrade option 12,000 gpm
• 1 ea.-14,000 GPM upgrade option
Nominal Range @ 100 PSI (straight stream)
@ 4,000 GPM 330 ft.
@ 6,000 GPM 350 ft.

@ 8,000 GPM 360 ft.


@ 10,000 GPM 390 ft.

@ 12,000 GPM 400 ft.

@ 14,000 GPM 430 ft.

Water Inlets (standard) Eight (8) 5” storz

Foam Concentrate Inlet Two (2) 4” storz


K- Factor, Maximum Flow 1400

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F10
www.williamsfire.com

Hydro-Foam™ Technology

monitor / nozzle packages


monitor / nozzle packages

“Big Foot” Trailer Mount 4,000 - 14,000 GPM

5” Storz Inlet
(Optional)

*Two Optional inlets required for flows from 10,000 gpm to 14,000 gpm.

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F11
www.williamsfire.com

Hydro-Foam™ Technology

monitor / nozzle packages


monitor / nozzle packages

“Big Foot” Hose Lay - For up to 8,000 GPM

(4)
(8) 5” Water Supply
Coupled 5” Storz
Hoses

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F12
www.williamsfire.com

Monitor / Nozzle Packages

monitor / nozzle packages


monitor / nozzle packages

Product:
Battler 2 x 10 Monitor / Nozzle

Description:
The “Battler” Monitor/Nozzle Trailer Unit is capable of
large volume discharge to elevations never before attained by
conventional equipment to provide fire suppression, cooling,
personnel protection, toxic gas dispersion and more. Discharge
flow rates from 2000-10,000 USGPM (7571-37854 LPM) can
be water or Hydro-Foam™ for extinguishing liquids. All this
and the operator is still afforded the freedom of smooth, rapid
horizontal and vertical movement and unsurpassed articulation
of 360˚ that only the “Battler” can provide, raising this monitor/
nozzle “above” all others.

Advancing the Fire Fighter’s Ability with


Equipment and Knowledge.
This “Hybrid” nozzle has the unique capability to perform as an automatic pressure or fixed gallonage nozzle. During
automatic operation the nozzle will respond to varying flows to maintain a nearly constant tip pressure, thus maximizing effec-
tive range for a given discharge flow. Once the nozzle reaches the fixed gallonage set point (2000-10,000 GPM), it performs
as a conventional fixed gallonage nozzle. This is desirable for foam proportioning operations on storage tank fires or other
hazards requiring specific application rates. This nozzle is capable of Hydro-Foam™ proportioning at rates up to 10,000
GPM @ 1% (8000 GPM @ 3%) using remote jet pump technology. The single 10” stainless steel waterway construction
provides minimum friction loss, maximum efficiency, and years of trouble-free service. The “user-friendly” gear operated
controls provide full monitor articulation of 360˚ rotation and down to +15˚ and up to +75˚ vertical travel with a minimal
of input effort. Pattern control from straight stream to full fog is accomplished via a full wrap-around handle attached to the
outer sleeve.

Standard Features:
Dual Mode Automatic/Fixed Operation
Fixed Gallonage plugs: 2K, 4K, 6K, 8K, 10K
Hydro-Foam™ Capable Nozzle
Efficient Single 10” SS Monitor
Dual Handwheel Controls for Pan & Tilt
Wrap-around handle design for pattern control
Tandem axle trailer
Integral 12” stainless steel manifold
Five 5” clappered storz inlets w/caps
2.0” ball fixed height hydraulic surge coupler
Large operator’s deck surface (8’ x 11’)
Anti-skid grip surface
Four point trailer jacks plus tongue jack
Standard grade Red Finish

Options:
6” clappered storz inlets in lieu of standard (nine)
2.0JP60 Jet Pump w/Metering Valve & Stinger (four)
4-2.5” FNST x 4.0” MNPSH Siamese Jet Pump Manifold
15’ x 4” ID Non-collapsible Jet Pump Supply Hose
2.5’” FNST x 2-1.5” MNST Gated Wyes for Jet Pump Feed (two)
European adjustable tow bar
European lighting package
Radio remote controlled electric/hydraulic/monitor controls
Premium (show grade) paint & finish

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F13
www.williamsfire.com

Monitor / Nozzle Packages

monitor / nozzle packages


monitor / nozzle packages

Product:
Ambassador 1 x 6 Monitor/Nozzle

Advancing the Fire Fighter’s Ability with Equipment


and Knowledge.

Description:
This “Hybrid” nozzle has the unique capability to perform as
an automatic pressure or fixed gallonage nozzle. During automatic
operation the nozzle will respond to varying flows to maintain a
nearly constant tip pressure, thus maximizing effective range for a
given discharge flow. Once the nozzle reaches the fixed gallonage
set point (1000-6000 GPM), it performs as a conventional fixed gal-
lonage nozzle. This is desirable for foam proportioning operations
on storage tank fires or other hazards requiring specific application
rates. This nozzle is capable of Hydro-Foam™ proportioning at
rates up to 6000 GPM @ 3% (3000 GPM @ 6%) using remote jet pump technology. The extensive “Ambassador” options list
allows this nozzle to be Hydro-Chem™ capable with PKW flow rates from 25 lbs/s to 100 lbs/s. The single 8” full flow stain-
less steel waterway construction provides minimum friction loss, maximum efficiency, and years of trouble-free service. The
standard tiller-bar control provides full monitor articulation of 360˚ rotation and down to -15˚ and up to +75˚ vertical travel.
Pattern control from straight stream to full fog is accomplished via a full wrap-around handle attached to the outer sleeve.

Standard Features:
Dual Mode Automatic/Fixed Operation
Fixed Gallonage plugs:1K,2K,3K,4K,5K,6K
Hydro-Foam™ Capable Nozzle
Efficient Single 8” SS Monitor
Tiller-bar control
Wrap-around handle design for pattern control
Tandem axle trailer
Integral 8” carbon steel manifold
Five 5” non-clappered storz inlets w/caps
2.0” ball fixed height hydraulic surge coupler
Anti-skid grip surface
Four point trailer jacks plus tongue jack
Standard grade Red Finish

Options:
Hydro-Chem™ Tip conversion
Choke tubes (25, 50, 75 & 100 lbs./s)
Dry chemical manifolds (4,6,7, & 10 inlets)
*See Pages J10-J12
1.5JP30 Jet Pump w/stinger (one)
2.0JP60 Jet Pump w/stinger (three)
3-2.5” FNST x 3.0” MNPSH Siamese
1-2.5” FNST x 3-1.5” MNST Wye
10” SS integral manifold w/6-5” Storz inlets
Internal 5” clappers
European adjustable tow bar
European lighting package
Gear operated monitor controls (vertical & horizontal)
Radio remote controlled electric/hydraulic/gear monitor controls
1-5” x 2-5” Jumbo Siamese (recommended w/std 8” manifold)
Premium (show grade) paint & finish
3” x 15’ Dry Chemical Hose
3” Valved Siamese w/extra hoses for 100 lbs./s “PKW™”

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F14
www.williamsfire.com

Monitor / Nozzle Packages

monitor / nozzle packages


monitor / nozzle packages

Product:
Ranger3™

Description:
“The Ranger™”, featuring “Smart Nozzle” Technology, was
designed for today’s Industrial fire fighting and protection needs.
Hazards involving flammable liquids in storage and liquids under
pressure have met their match with the New Millennium Equipment
from Williams Fire & Hazard Control, Inc®.

The “Ranger™” monitor/nozzle combination is capable of not


only self-educting foam concentrate, but can do so while maintaining
a nearly constant pressure (+/- 10%) and a constant foam percentage
(1% or 3% selectable) regardless of the flow rate. Discharge flow
rates from 1000-3000 USGPM (3800-11356 LPM) can be water only,
Hydro-Foam™ (using jet pumps or automatic constant/selectable
metering) or Hydro-Chem™ for extinguishing liquids and gases under pressure. All this and the operator is still afforded the
freedom of smooth, rapid horizontal and vertical movement that only the “Ranger™” can provide, raising this monitor/nozzle
“above” all others.

This “Hybrid” nozzle has the unique capability to perform as an automatic pressure or fixed gallonage nozzle. During
automatic operation the nozzle will respond to varying flows to maintain a nearly constant tip pressure, thus maximiz-
ing effective range for a given discharge flow. Once the nozzle reaches the fixed gallonage set point (1000-3000 GPM),
it performs as a conventional fixed gallonage nozzle. This is desirable for foam proportioning operations on storage tank
fires or other hazards requiring specific application rates. This nozzle is capable of Hydro-Foam™ proportioning at rates
up to 3000 GPM @ 3%. It can automatically maintain a nearly constant foam percentage (1% or 3%) throughout the entire
flow range while self-educting. It can optionally be configured to proportion foam from remote locations using jet pump
technology (thus forfeiting the constant/selectable metering feature). The extensive “Ranger™” options list allows this
nozzle to be Hydro-Chem™ capable (without Hydro-Foam™ capability) with “PKW™” flow rates from 25 lbs/s to 50 lbs/
s. The single 6” full flow stainless steel waterway construction provides minimum friction loss, maximum efficiency, and
years of trouble-free service. The standard tiller-bar control provides full monitor articulation of 360˚ rotation and down to
-15˚ and up to +75˚ vertical travel. Pattern control from straight stream to full fog is accomplished via a full wrap-around
handle attached to the outer sleeve.

Standard Features List: Options:


Dual Mode Automatic/Fixed Operation Hydro-Chem™ Tip conversion
Fixed Gallonage plugs: 1K, 2K, 3K Choke tubes (25 or 50 lbs/s)
Hydro-Foam™ Constant/Selectable Dry chemical manifolds (4 inlet or 7 inlet)
1% or 3% Nozzle *See Pages J10-J12
Efficient Single 6” SS Monitor 1.5JP30 Jet Pump w/stinger (one)
Tiller-bar control 2.0JP60 Jet Pump w/stinger (one)
Wrap-around handle design for pattern control 3-2.5” FNST x 3.0” MNPSH Siamese
Tandem axle trailer (Jet to Monitor Supply)
Integral 8” carbon steel manifold 1-2.5’” FNST x 3-1.5” MNST Wye
Three 5” non-clappered storz inlets w/caps (Jet Pump Supply)
2.0” ball fixed height hydraulic surge coupler 8” SS integral manifold w/3-5” Storz inlets
Anti-skid grip surface 8” SS integral manifold w/2-6” Storz inlets
Four point trailer jacks plus tongue jack Internal 5” or 6”clappers
Standard grade Red Finish European adjustable tow bar
European lighting package
Gear operated monitor controls
(vertical & horizontal)
Radio remote controlled electric/hydraulic/gear
monitor controls
Premium (show grade) paint & finish
2.5” x 10’’ Dry Chemical Hose

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F15
www.williamsfire.com

Monitor / Nozzle Packages

monitor / nozzle packages


monitor / nozzle packages

Product:
“Hired Gun” Trailer - 2000 GPM

Description:
This Trailer Mounted System delivers 2000 gpm of water or foam
solution @ 100 psi. Hard anodized nozzle with fog/straight stream
adjustment. Foam solution is proportioned through one matched Jet Ratio
Controller. Monitor is constructed of 6” stainless steel epoxy coated, gear
operated, with pressure gauge. Dual handwheel control, horizontal and
vertical positions. Heavy duty trailer includes: diamond plate deck; tool
box; and trailer hitch. Water inlet trim includes; 5” storz clappered dual
inlet siamese; 5” x 10 ft. hose coupled storz. Trailer is equipped with
adjustable jacks for stability.

2” BALL COUPLER STANDARD


(ELECTRIC OR SURGE BRAKES OPTIONAL)

Hired Gun
Trailer Mount
Nominal Flow @ 100 PSI 2000 gpm

Nominal Range @ 100 PSI 235 ft.


(straight stream)

Water Inlet 5” storz

Foam Concentrate Inlet 2.5” NH (F) Swivel

Horizontal Rotation 360º

Vertical Travel 0º to 85º

Proportioning 1% or 3%

K-Factor 200

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F16
monitor / nozzle packages

CLAPPERED JUMBO SIAMESE


5” STORZ X (2) 5” STORZ
Typical Hired Gun Layout

409 - 745 - 3232


PRODUCT INFORMATION
Monitor / Nozzle Packages

For US and Foreign Patent and Trademark information, please refer to page IP2

F17
JET RATIO CONTROLLER
(2.0) JP60
1.5” INLET X 2.5”
DISCHARGE
www.williamsfire.com

NOTE:

1. USE ONE JET RATIO CONTROLLER (2.0 JP60) FOR 3% @ 2000 GPM.
2. USE TWO JET RATIO CONTROLLERS (2.0 JP60) FOR 6% @ 2000 GPM.

24-HR EMERGENCY
409 - 727 - 2347
01152005
monitor / nozzle packages
www.williamsfire.com

Hydro-Chem™ Monitor / Nozzle Package

monitor / nozzle packages


monitor / nozzle packages

Product:
Patriot Ranger3™
“Quick Action” Deck Gun, 1000-3000 GPM

Description:
Hydro-Chem™ Monitor system includes: fog/straight stream constant
pressure/variable flow nozzle delivering from 1000 to 3000 gpm of foam
solution @ 100 psi and 40 lb./sec of dry chemical (nominal flow). Foam
solution is proportioned through one matched Jet Ratio Controller. Monitor
is constructed of stainless steel with red epoxy finish. Nozzle is constructed
of hard anodized aluminum alloy with stainless steel trim. Equipped with
quick action handle for fast, positive control. System includes: valved dry
chemical six inlet manifold; dry chemical inlet hose.

Patriot Ranger3™
Deck Gun “Quick Action”
Nominal Flow @ 100 PSI 1000, 2000 or 3000 gpm
K-Factors @ 100 psi Variable 100, 200, 300
Nominal Range of dry chemical 100 ft.
Foam Concentrate Inlet 2.5” NPT (M)
Dry Chemical Inlet Nozzle 2” NPT (M) Valved
Water Inlet 6” 150# flange
Vertical Travel 0º to +80º
Horizontal Rotation 360º

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F18
www.williamsfire.com

Monitor / Nozzle Packages

monitor / nozzle packages


monitor / nozzle packages

Product:
Gear Operated 6” Monitor

Description:
This Fixed Mounted System delivers from 1000 to 3000 gpm of water
or foam solution @ 100 psi. Hard anodized constant pressure/variable flow
nozzle with fog/straight steam adjustment. For remote application, 1% or
3% foam solution is proportioned through one matched Jet Ratio Controller.
Worm gear operated 6” waterway monitor is constructed of stainless steel
with stainless steel swivels. Dual handwheels control horizontal and vertical
positions.

Patriot Ranger3™
Nominal Flow @100 psi 1000, 2000 or 3000 gpm

Water inlet 6” Flange

Foam Concentrate Inlet 2.5” NPT(M)

Horizontal Rotation 360º

Vertical Travel 0º to +90º

Proportioning without jet 1% or 3%

K-Factor (@ 100 psi) 100, 200 or 300

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F19
www.williamsfire.com

Hydro-Chem™ Monitor / Nozzle Package

monitor / nozzle packages


monitor / nozzle packages

Product:
Patriot 1- “Worm Gear” Deck Gun, 1000 GPM

Description:
Hydro-Chem™ Monitor system, includes fog/straight stream nozzle,
delivering 1000 gpm of foam solution @ 100 psi and 20 lb./sec of dry
chemical (nominal flow). Foam solution is proportioned through one
1.5 JP30 Jet Ratio Controller. Dual handwheel 4” monitor is fabricated
of stainless steel with red epoxy finish. “Dual Wafer” Nozzle is con-
structed of hard anodized aluminum alloy with stainless steel trim. System
includes: valved dry chemical four inlet manifold; dry chemical inlet hose,
1.5” x 15 ft.

Patriot 1 Deck Gun


“Worm Gear”
Nominal flow @ 100 PSI 1000 gpm

K-Factor 100

Nominal Range of dry chemical 100 ft.

Foam Concentrate Inlet 2” NPT (M)

Dry Chemical Inlet Nozzle 1.5” Valved

Water Inlet 4” 150# flange


Vertical Travel -10º to +90º

Horizontal Rotation 360º

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F20
www.williamsfire.com

Hydro-Chem™ Monitor / Nozzle Package

monitor / nozzle packages


monitor / nozzle packages

Product:
1.5 HC Ranger™ 250-1500 Deck Gun

Description:
Hydro-Chem™ Monitor System, includes fog/
straight stream constant pressure/variable flow nozzle,
delivering from 250 gpm to 1500 gpm of foam solution
@ 100 psi and 20 lb./sec of dry chemical (nominal flow).
Foam solution is proportioned through one matched Jet
Ratio Controller. Monitor is constructed of stainless steel
with red epoxy finish. “Big Body Nozzle” is constructed
of hard anodized aluminum alloy with stainless steel trim.
Equipped with “quick action” handle for fast, positive
control. System includes: valved dry chemical four inlet
manifold; dry chemical inlet hose, 1.5” X15 ft.
Patriot Ranger™ Deck Gun
Nominal Flows Variable (250-1500 GPM)

Nominal Flow @ 100 PSI 1500 gpm

K-Factor 150

Nominal Range of dry chemical 100 ft.

Dry Chemical Inlet Nozzle 1.5” Valved

Water Inlet 4” 150# flange

Vertical Travel -25º to +80º

Horizontal Rotation 360º

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
F21
www.williamsfire.com

WATER SUPPLY / HYDRANT


water supply / hydrant

water supply / hydrant


SECTION INDEX

Water Discharge Manifold - High Volume 12” “Type A”.................................................................................................G2


Hose Connections (only)

Water Discharge Manifold - High Volume 12” “Type B”.................................................................................................G3


Hose Connections with Monitor Mounting Flange (Blind)

10” Ring Main Manifold................................................................................................................................................................... G4

6” Wet Barrel Hydrant.....................................................................................................................................................................G5

8” Wet Barrel Hydrant.....................................................................................................................................................................G6

3” Wet Barrel Hydrant.......................................................................................................................................................................G7

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G1
www.williamsfire.com

Water Supply / Hydrant Section


water supply / hydrant

water supply / hydrant


Water Discharge Manifold - High Volume 12” “Type A”
Hose Connections (only)

Description:
High volume monitors require a water inlet supply system (piping and hose) with minimum restrictions. In nearly all
cases, Williams’ High volume (2,000 gpm to 14,000 gpm) nozzles should be supplied with either 5” or 6” diameter hose
from the discharge manifold to the gun. Also, in most cases, high volume hose connections are “Storz” quick-connect type.
Because most existing fire hydrants are not
provided with high volume outlets, Williams
designs and fabricates special High Volume
Water Discharge Manifolds for use with high
capacity monitors. The “Type A” general
configuration is shown below.

PLAN

ELEVATION

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G2
www.williamsfire.com

Water Supply / Hydrant Section


water supply / hydrant

water supply / hydrant


Water Discharge Manifold - High Volume 12” “Type B”
Hose Connections with Monitor Mounting Flange (Blind)

Description:
High volume monitors require a water inlet supply system (piping and hose) with minimum restrictions. In nearly all
cases, Williams’ High volume (2,000 gpm to 14,000 gpm) nozzles should be supplied with either 5” or 6” diameter hose
from the discharge manifold to the gun. Also, in most cases, high volume hose connections are “Storz” quick-connect type.
Because most existing fire hydrants are not provided with high volume outlets, Williams designs and fabricates special High
Volume Water Discharge Manifolds for use with high capacity monitors. The “Type B” general configuration is shown
below.

PLAN

ELEVATION

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G3
www.williamsfire.com

Water Supply / Hydrant Section


water supply / hydrant

water supply / hydrant


10” Ring Main Manifold

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G4
www.williamsfire.com

Water Supply / Hydrant Section


water supply / hydrant

water supply / hydrant


6” Wet Barrel Hydrant

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G5
www.williamsfire.com

Water Supply / Hydrant Section


water supply / hydrant

water supply / hydrant


8” Wet Barrel Hydrant

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G6
www.williamsfire.com

Water Supply / Hydrant Section


water supply / hydrant

water supply / hydrant


3” Wet Barrel Hydrant

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
G7
www.williamsfire.com

TRANSPORTABLE EXTINGUISHING SYSTEMS


transportable extinguishing systems

transportable extinguishing systems


SECTION INDEX

Ansul 350 lb. “PKW™” Dry Chemical Wheeled Fire Extinguisher...............................................................H2

Hydro-Chem™ “PKW™” Wheeled Handline Extinguishing System............................................................H3

Ansul High Flow “PKW™” Dry Chemical Wheeled Unit Storage & Delivery System.............................H4

Quick Attack Foam Cart................................................................................................................................................H5

Three Wheeled Portable Cart....................................................................................................................................H6

Four Wheeled Portable Cart....................................................................................................................................... H7

Hydro-Foam™ “Tote” Trailer.......................................................................................................................................H8

Hydro-Foam™ “Dual Tote” Trailer............................................................................................................................H9

Tri-Agent Trailer............................................................................................................................................................H10

Balanced Pressure Proportioning Trailers...............................................................................................H11-H12

Foam Nurse Trailer with Jets...................................................................................................................................H13

Hose Trailer....................................................................................................................................................................H14

Large Hose Trailer........................................................................................................................................................H15

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H1
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Ansul 350 lb. “PKW™” Dry Chemical Wheeled Fire
Extinguisher

Description:
This initial intervention wheeled extinguisher incorporates Ansul’s
renowned quality with Williams’ specialized highly-visible “PKW™” Dry
Chemical. Ansul’s “PKW™” wheeled fire extinguisher has a total dry
chemical capacity of 300 lbs. It is equipped with a quick opening valve and
regulator to maintain a constant pressure and flow throughout the total extin-
guisher discharge. Extinguisher also includes: hard rubber discharge hose,
50 ft; fill cap indicator; spoked metal wheels; and corrosion control coating.
Equipped with the standard Ansul dry chemical discharge nozzle, rated 7.5
lb./sec., with a nominal effective range (still air) of 30 ft. Discharge time of
a fully-charged extinguisher is approximately 40 seconds.

Williams’ “PKW™” is a potassium bicarbonate based dry chemical


containing colorized additives. It is a highly specialized siliconized Purple-
K (deep purple color) that is one of the most effective dry chemicals used to
extinguish flammable and/or combustible liquid fires. The agent is free-flow-
ing, water repellent and non abrasive and, when used as a fire extinguishing
agent, will produce no toxic effects.

Ansul “PKW™” 350# Wheeled Fire Extinguisher


PKW™-WU-350

Dry Chemical Capacity 350 lbs.

Dry Chemical Type Williams “PKW™”

Dry Chemical Flow(lbs/s) 7.5

Application Class “B” Flowing Liquid Fires

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H2
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Hydro-Chem™ “PKW™” Wheeled Handline
Extinguishing System

Description:
Hydro-Chem™ “PKW™” Wheeled Handline Extinguishing System
incorporates 300 lbs. of specialized “PKW™” dry chemical in transportable
storage; a dual flow (HCHG) Series Hydro-Chem™ Handline Nozzle; and “flat
lay” dry chemical delivery hose. This assembly, when combined with foam
solution, is complete and ready to use in combating three dimensional and/or
pressurized fuel fires. Unit provides dry chemical flows at 10 lbs/s and foam
solution rates at 60, 95 or 125 gpm.

“PKW™” is a highly specialized siliconized Purple-K that is one of the


most effective dry chemicals used to extinguish flammable and/or combustible
liquid fires. Its distinctively deep purple color provides the fire fighter with
the ability to stay ON-TARGET when it is projected to the fire within the
foam/water stream. This results in a quicker, more effective “knockdown,”
and extinguishment.

System includes:
Ansul wheeled fire extinguisher; flat lay discharge hose; 1.5” x 100 ft. coupled, 1.5” NH; Williams “PKW™” dry
chemical 300 lbs.; HCHG, Series “Handgun” Hydro-Chem™ Nozzle.

PKW™ Wheeled PKW™-WW-350 PKW™-WW-350 PKW™-WW-350


Extinguisher System HCHG-60 HCHG-95 HCHG-125
Dry Chemical Capacity 300 lbs. 300 lbs. 300 lbs.
Dry Chemical Type “PKW™” Purple K “PKW™” Purple K “PKW™” Purple K
Foam Solution 60 gpm 95 gpm 125 gpm
Flow Range Flow
(@ 100 psi)
Dry Chemical 10 10 10
Flow (lbs/s)
Application Class “B” Flowing Liquid Fires

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H3
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Ansul High Flow “PKW™” Dry Chemical
Wheeled Unit Storage & Delivery System

Description:
Ansul “PKW™” High Flow Wheeled Unit, is modified and designed to
be used exclusively in conjunction with Hydro-Chem™ discharge devices
(nozzle and/or delivery manifolds), which are ordered separately. This tech-
nology allows the fire to be extinguished at ranges not possible with conven-
tional dry chemical equipment. Refer to adjacent page for typical layouts.

“PKW™” storage capacity is 300 lbs. Includes: flat lay discharge hose,
100 ft. coupled 1.5” (M) NPSH; fill cap indicator; spoked metal wheels; cor-
rosion control coating.

“PKW™” is a highly specialized siliconized Purple-K that is one of the


most effective dry chemicals used to extinguish flammable and/or combus-
tible liquid fires. It is commonly used in conjunction with Hydro-Chem™
Technology to effectively extinguish pressurized or three dimensional “Class
B” liquid fires. Williams’ “PKW™” is a potassium bicarbonate based dry
chemical containing chemical additives. The agent is free-flowing, water
repellent and non abrasive and, when used as a fire extinguishing agent will
produce no toxic effects. Its distinctively
deep purple color provides the fire fighter
with the ability to stay ON-TARGET when
the dry chemical is projected to the fire with-
in the foam/water stream. The result, when
combined with Hydro-Chem™ Technology
is the ability to achieve a quicker and more
effective “knockdown,” in addition to using
less chemical to complete the job.

Ansul PKW™ Wheeled Unit


PKW™-WHC-350
Dry Chemical Capacity 300 lbs.

Dry Chemical Type Williams “PKW™”

Dry Chemical Flow(lbs./s) 10

Application For use with Hydro-Chem™


Delivery Systems

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H4
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Quick Attack Foam Cart

Description:
More than a portable monitor, the Quick Attack foam cart can easily be
operated by one person. Ideal for spill fires in chemical plants and flamma-
ble liquid storage areas. A single mobile unit can be used to protect several
different remote hazard areas. Unlike eductor style foam stations this unit
operates effectively and proportions foam even at low water inlet pressures.
Minimum recommended inlet pressure is 70 psi. Foam stream projects from
monitor approximately 50 ft. at 70 psi inlet pressure (straight stream in still
air). Equipped complete with: supply hose, 2” x 100 ft. coupled 1.5” NH;
brass Spectrum “Mini-Monitor”; pre-plumbed self-educting brass Hydro-
Foam™ Small Body Monitor Nozzle, rated 150 gpm or 225 gpm @ 100
psi inlet. Stainless steel 35 gallon capacity foam concentrate storage tank
is fitted with fill opening, pressure vacuum vent and drain valve. 15” semi-
pneumatic wheels. Specify 1% and/or 3% proportioning. Red vinyl Quick
Attack cover is available as an option.

Model Nozzle rating GPM Approximate foam Proportioning


Quick Attack Foam Cart @100 psi duration in minutes
QA-150-1 150 23.3 1%
QA-150-3 150 7.7 3%
QA-225-1 225 15.6 1%
QA-225-3 225 5.2 3%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H5
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Three Wheeled Portable Cart

Description:
Water or foam capacities of up to 1,000 gpm. Provided with
500 gpm “BTM” brass fog/straight stream nozzle and “Spectrum 3”
single worm gear operated cast brass monitor. Full 4” I.D. manifold
with two (2) clappered 2.5” NH (F) rear mounted swivel inlets, and
0-300# pressure gauge. Equipped with two pneumatic tires and
a single front demountable dolly-type wheel with folding handle.
Options include: dual hose racks with capacities of 50 ft., 3” hose;
additional front or rear mount 2.5” NH (F) swivel inlets. If ordering
with Hydro-Foam™ nozzle specify type as well as foam % for foam
proportioning and delivery.

OPTIONS
• Dual Hose Racks (capacity 50 feet)
of 3” Hose (shown)
• Additional Front or Rear Inlets
• 5” Storz Inlets
• Hydro-Foam™ Nozzle

Pulling Handle

Max Flow Standard Flow Monitor


K-Factor Inlets (two)
Three Wheeled @100 PSI @ 100 PSI Waterway
Portable Cart
up to 1,000 500 gpm 50 3” I.D. 2.5” NH(F) Clappered

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H6
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Four Wheeled Portable Cart

Description:
Water or foam capacities of up to 500 gpm. Provided with
500 gpm “BTM” brass fog/straight stream nozzle and standard
Spectrum tiller bar control cast brass monitor. Full 4” I.D. manifold
with two (2) clappered 2.5” NH (F) rear mounted swivel inlets, and
0-300# pressure gauge. Equipped with four (4) locking pneumatic
tires with “tee-bar” control handle. Options include: dual hose
racks with capacities of 50 ft. rolls, 3” hose; additional front or rear
mount 2.5” NH (F) swivel inlets. If ordering with Hydro-Foam™
nozzle specify flow rate (up to 500 gpm) as well as either 1% or
3% proportioning.

OPTIONS
• Dual Hose Racks (capacity 50 feet)
• Additional Front or Rear 2.5” Inlets
(shown)
• 5” Storz Inlets
• Hydro-Foam™ Nozzle

Max Flow Standard Flow


K-Factor Monitor Inlet (two)
Four Wheeled @100 PSI @ 100 PSI
Portable Cart 2.5” NH(F)
up to 500 500 gpm  50 3” I.D.
Clappered

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H7
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Hydro-Foam™ “Tote” Trailer

Description:
Hydro-Foam™ Tote Trailers provide high volume foam
storage, proportioning and delivery capability in a competi-
tively priced package. Each trailer is designed and manufac-
tured to meet specific project requirements. In general, this
transportable flammable liquid fire fighting system consists
of: dual axle, 7,000 lb. GVW, DOT trailer, with tongue-
mounted leveling jack, surge brakes, and skid-resistant deck
surface; 265 gallon capacity ThunderStorm® ATC 1% x 3%
Foam Tote is constructed of high density polyethylene with a
reinforced aluminum enclosure; clappered water inlet mani-
fold, with one (1) 5” Storz inlet connection; Spectrum manual
high-flow station monitor, 3” cast brass, with 4” worm gear
type butterfly inlet control valve; HF Ranger™ Select Hydro-Foam™ Nozzle, 1.0 rated 1,000 gpm @ 100 psi, complete with
foam concentrate siphon hose to tank bottom; two (2) fender-mounted welded-wire type steel storage compartments, each with
capacity to inventory up to 100 ft., 5” hose (or 300’ of 3”); red polyurethane finish.

Hydro-Foam™ Flow@ 100 psi Proportioning Inlet Concentrate Storage


Tote Trailer 1,000 gpm 1%/3% 5” Storz 265 gallons

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H8
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Hydro-Foam™ “Dual Tote” Trailer

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H9
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Tri-Agent Trailer

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H10
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Balanced Pressure Proportioning Trailers

Description:
With variable flow capability, balanced
pressure proportioning trailers are ideal for
supplemental foam solution injection into
semi-fixed foam systems, including: sprinkler
risers; topside foam chambers; foam makers;
or high back pressure foam makers for subsur-
face injection into hydrocarbon storage tanks.
Proportioning rates, tank sizes, inlet and dis-
charge manifolds are sized and configured to
client requirements.

Equipped with nursing capability these


systems are re-fillable during operation.
Standard proportioning package delivers
foam @ 1%, 2% and/or 3%. Nominal foam
solution flow is between 250 and 1250 gpm,
utilizing a 4” ratio flow controller and 1.5”
pressure control valve and 100 gpm @ 200 psi diesel driven concentrate pump. Optional flow rates up to 3,000 gpm can be
achieved through the use of a larger ratio flow controller, manifold, piping and concentrate pump.

Accessible pump, driver and piping provide ease of maintenance. Cross linked high density polyethylene 1000 gallon
foam storage tank with floating baffles, mounted on carbon steel support saddles. Butterfly valve, worm gear type, is installed
on water inlet. Optional Spectrum 3” brass monitor, valved, with a Ranger™ 250-750 gpm, 1% or 3% automatic Hydro-
Foam™ nozzle provides supplemental foam proportioning and delivery.

Auxiliary
Valved Concentrate
Balanced Flow @100 psi Proportioning Valved Inlet Concentrate
Discharge Discharge
Pressure Suction
Trailer 1 ea.,
250-1,250 gpm 1%/3% 1 ea., 5”storz 1 ea., 2.5” NH (M) 2.5” NH (M)
5”storz

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H11
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Balanced Pressure Proportioning Trailers

PLAN

Floating baffles

ELEVATION

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H12
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Foam Nurse Trailer with Jets

Description:
The Spectrum Foam Nurse Trailer with Jets provides an efficient and effective way to store and hydraulically deliver large
quantities of ThunderStorm® Foam Concentrate to either single or multiple self-educting Hydro-Foam™ end-of-line devices.
The trailer system consists of the following major components; dual axle, 24,000 lb GVW chassis; 2,000 gallon (total capac-
ity) compartmented, horizontally configured high density polyethylene foam storage tank(s) with trim; carbon steel cradle;
manifold of Jet Ratio Controllers and valving, sized and configured to address project (hazard) requirements; two (2) hose
storage bins, side mounted; heavy duty tongue constructed of C5 channel, with ball hitch and leveling jack; electric brakes.
Finished in red polyurethane.

Gross Vehicle Foam Capacity Brakes Height (nominal) Width (nominal) Length (nominal)
Weight (nominal)
24,000 lbs 2,000 gallons Electric 79.25” 96” 20 ft.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H13
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Hose Trailer

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H14
www.williamsfire.com

Transportable Extinguishing Systems


transportable extinguishing systems

transportable extinguishing systems


Product:
Large Hose Trailer

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
H15
www.williamsfire.com

FOAM STATIONS
foam stations

foam stations
SECTION INDEX

Hydro-Foam™ Monitor Stations Overview..............................................................................................................................I2

Standard Hydro-Foam™ Monitor Stations 3”, 350-750GPM..........................................................................................I3

High-Flow Constant Pressure Hydro-Foam™ Ranger™ Monitor Stations 4”, 250-1,500 GPM.....................I4

Drum Kit & Double Drum Kit...........................................................................................................................................................I5

Transportable Foam “Tote” - 265 Gallon (1000 Liter) Capacity................................................................................. I6

“Minuteman” Foam Hose Reel Station......................................................................................................................................I7

“Minuteman II” Foam Hose Reel Station with Low Flow Hydro-Foam™ Monitor................................................I8

“Minuteman III” Foam Hose Reel Station with Medium Flow Hydro-Foam™ Monitor............................. I9-I11

Continuous Flow Hose Reel Station.........................................................................................................................................I12

Hose Reel Foam Station-Bladder Tank Style - 40 Gallon............................................................................................. I13

Quick Attack Foam Cart..................................................................................................................................................................I14

Oscillating Monitor Foam Station.................................................................................................................................... I15-I16

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I1
www.williamsfire.com

Hydro-Foam™ Monitor Stations


foam stations

foam stations
*Available in 30 gallon, 55 gallon, 265
gallon containers
Product Application
Firewater monitors are normally installed, or otherwise made available
for exposure protection throughout industrial facilities that process and/or inventory flammable liquids. When employed for
water application, they can also serve a dual purpose and be used for applying foam for vapor suppression and/or spill fire pro-
tection. Firewater monitors are easily converted to this dual “foam/water” application through the use of a separate/dedicated
foam reservoir and a Hydro-Foam™ Nozzle installed on each monitor.

HYDRO-FOAM™ MONITOR STATIONS PROVIDE THE FOLLOWING ADVANTAGES over Handline Hose
Stations utilizing Inline Eductors.

Hydraulic Efficiency
Hydro-Foam™ Monitors operate effectively at lower inlet pressures, when compared to handline nozzles used in conjunc-
tion with inline eductors.

Inline eductors require a nominal 35% of the available water inlet pressure in order to proportion foam. This pressure
drop, when combined with the pressure loss through the delivery hose to the nozzle, translates into required inlet pressures of
approximately 50 psi greater than what is needed for Hydro-Foam™ monitors to operate.

FIRE FIGHTING CAPABILITY


Hydrocarbon spill fires require a minimum nominal foam application density of 0.1 gpm per sq. ft. Therefore, a 100 gpm
handline has the capability of controlling and suppressing approximately 1000 sq. ft. of flame surface area. Scaled up, a 500
(750, 1,000) gpm foam water monitor has the capability of controlling and suppressing 5 (7.5, 10) times the flame surface
area versus that of a 100 gpm handline nozzle.

OPERATOR SAFETY
Monitors flowing between 500 and 1,000 gpm have an effective range which is about 3 times farther than that of a 100
gpm handline. This greater projection of foam or water translates proportionally into more safety for the operator. In addition,
when the monitor nozzle is adjusted to the “FULL FOG” position the higher volume of foam or water provides proportionally
more cooling for the operator. Also, (as opposed to handlines) monitors can be set up and adjusted - then temporarily left
unattended, if necessary.

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I2
www.williamsfire.com

Hydro-Foam™ Monitor Stations


foam stations

foam stations
Product:
Standard Hydro-Foam™ Monitor Stations 3”, 350-750 GPM

General:
Hydro-Foam™ Monitor Stations are recognized as the standard for front-line
fire prevention/suppression foam application systems. They are used extensively
in hydrocarbon processing and petrochemical plants throughout the world. Hydro-
Foam™ Monitor Stations are typically installed in high-hazard/high value areas
such as process units, tank farms, truck loading racks, rail terminals and marine
facilities. Because of their inherent ease of operation, Hydro-Foam™ Monitor
Stations, when used by trained operators and fire fighters, have assisted in the sig-
nificant reduction of industrial fire losses.

Description:
Complete Standard Hydro-Foam™ Station with 3” waterway monitor. 1% or
3% proportioning up to 750 gpm. System consists of: Standard Spectrum Monitor,
3” cast brass with tiller bar manual controls; Hydro-Foam™ Medium Body Brass Nozzle and Drum Kit. Monitor with either
a 3” ASA 150# flanged base, or a 4” ASA 150#
flanged base.
Hydro-Foam™ STATION
COMPONENTS

Hydro-Foam™ Monitor Station Consists of:


1. Hydro-Foam™ Nozzle with Flex Hose
2. Spectrum Monitor
3. Drum Kit
4. ThunderStorm® ATC Drum

By simply opening two valves (for water


ThunderStorm®

AFFF/ATC
and foam control), ThunderStorm® ATC is
easily and safely proportioned and delivered to
either cover unignited fuel spills or to apply onto
flammable/combustible liquid fire.

Foam Duration
Flow rate
Standard HYDRO-FOAM™ Model
@100PSI
Foam Proportioning (minutes)
MONITOR STATIONS
with LW Nozzles HMS-350-1 350 gpm 1% 15
HMS-350-3 350 gpm 3% 5
HMS-500-1 500 gpm 1% 11
HMS-500-3 500 gpm 3% 3.5
HMS-700-1 700 gpm 1% 7.5
HMS-700-3 700 gpm 3% 2.5

Flow rate Foam Duration


Standard HYDRO-FOAM™ Model Foam Proportioning
@100PSI (minutes)
MONITOR STATIONS HMS-500NS-1 500 gpm 1% 11
with LWNS Nozzles HMS-500NS-3 500 gpm 3% 3.5
HMS-750NS-1 750 gpm 1% 7.3
HMS-750NS-3 750 gpm 3% 2.4

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I3
www.williamsfire.com

Hydro-Foam™ Monitor Stations


foam stations

foam stations
Product:
High-Flow Constant Pressure Hydro-Foam™ Ranger™
Monitor Stations 4” 250-1,500 GPM

General:
Hydro Foam™ Monitor Stations are recognized as the standard for front-
line fire prevention/suppression foam application systems. They are used
extensively in hydrocarbon processing and petrochemical plants throughout
the world. Hydro-Foam™ Monitor Stations are typically installed in high-
hazard/high value areas such as process units, tank farms, truck loading
racks, rail terminals and marine facilities. Because of their inherent ease of
operation, Hydro-Foam™ Monitor Stations, when used by trained
operators and fire fighters, have assisted in the significant reduction
of industrial fire losses.

Description:
Complete High-Flow Constant Pressure Hydro-Foam™ Station
with 4” waterway monitor. Constant metering 1% or 3% proportion-
ing through the entire nozzle. Flow range — 250-1500 gpm. System
consists of: Ranger™ HF Series Aluminum Nozzle and Drum Kit.
4” ASA flanged base.

By simply opening two valves (for water and foam control),


ThunderStorm® ATC is easily and safely proportioned and delivered to either cover unignited fuel spills or to apply onto
flammable/combustible liquid fire.

“High Flow” Hydro-Foam™ Monitor Station Hydro-Foam™ Station


Consists of:
Components
1. HF-Ranger™ Automatic Hydro-
Foam™ Nozzle with Flex Hose
2. Spectrum Monitor - 4”
3. Drum Kit
4. ThunderStorm® ATC
Foam Concentrate Drum

ThunderStorm®

AFFF/ATC

“High Flow” Hydro-Foam™ Monitor Stations

Model Flow Range Flow Rate @100PSI Metered Proportioning


HMSR 1.0-1 250-1000 gpm 1000 gpm 1%

HMSR 1.0-3 250-1000 gpm 1000 gpm 3%

HMSR 1.5-1 250-1500 gpm 1500 gpm 1%

HMSR 1.5-3 250-1500 gpm 1500 gpm 3%

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I4
www.williamsfire.com

Hydro-Foam™ Monitor Station Accessories


foam stations

foam stations
Product:
Drum Kit & Double Drum Kit

Description:
A “Drum Kit” is the link between any Hydro-Foam™ Nozzle and an
atmospheric foam tank. The standard drum kit consists of: flexible rein-
forced clear foam pick-up hose; foam concentrate valve, pvc, quarter-turn
ball type; rigid pvc concentrate pick-up tube (“stinger”); pressure/vacuum
vent. Custom configurations can also be provided for use with totes, or
larger atmospheric foam tanks. Specify model and flow rate of Hydro-
Foam™ Nozzle and length of hose (if other than 8’ ) that Drum Kit is to
be used with.

Double Drum Kit is used to connect two (2) drums or tanks to a Hydro-
Foam™ Nozzle, and consists of: pvc tee; two (2) flexible hoses; one (1)
90˚ pvc elbow; two (2) foam concentrate control valves, pvc, quarter-turn
ball type; two (2) pvc “stingers”; and two (2) pressure/vacuum vents.

Drum Kit

Double Drum Kit

Standard Drum Kits Double Drum Kits


DKSB Small Body LW Nozzle DDKSB Small Body LW Nozzle

DKHF Medium Body HF Elkhart Nozzle DDKHF Medium Body HF Elkhart Nozzle

DKMB-O Medium Body Original Style LW Nozzle DDKMB-O Medium Body Original Style LW Nozzle

DKMB-N Medium Body New Style LWNS Nozzle DDKMB-N Medium Body New Style LWNS Nozzle

DKBB-R Ranger™ HF Nozzle DDKBB-R Ranger™ HF Nozzle

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I5
www.williamsfire.com

Hydro-Foam™ Monitor Station Accessories


foam stations

foam stations
Product:
Transportable Foam “Tote”
265 Gallon (1000 Liter) Capacity

Description:
All Hydro-Foam™ Monitor Stations can now be supplied with
ThunderStorm® ATC transportable foam totes. 265 gallons of
ThunderStorm® ATC concentrate is included with each tote. The
larger foam concentrate capacity of the Tote matches up ideally with
High Flow “Ranger™” Hydro-Foam™ Monitor Stations. Molded
cross-linked, high density polyethylene tank is equipped with: rein-
forced metal enclosure; carbon steel base with fork lift channels;
threaded top inspection hatch; valved (2” cam-lock) pvc fill/drain
bottom fitting. Optional pressure/vacuum vent is provided when
used in conjunction with Hydro-Foam™ Monitor Station.

265 GAL
TOTE

*Available in 30 gallon, 55 gallon, 265 gallon containers

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I6
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
“Minuteman” Foam Hose Reel Station

Description:
Fixed, self contained hose reel foam station features a built-in foam concentrate stor-
age tank and a 95 GPM (or 60 gpm) 1% (or 3%) foam eductor with water bypass. Includes
a 60 gallon stainless steel foam concentrate storage tank, complete with: pressure/vacuum
vent; 6” fill opening, capped; .75” drain plug; lifting eyes; rigid concentrate pick-up line
to tank bottom. Continuous flow hose reel is equipped with 100 feet of 1.5” hard rubber
hose and a constant flow 95 gpm (or 60 gpm) fog/straight stream nozzle. Equipped with
brass water inlet manifold. Red polyurethane paint finish.

6”

Minuteman Hose Reel Stations

Model Model 601 Model 951 Model 603 Model 953


Flow @ 150 PSI 60 gpm 95 gpm 60 gpm 95 gpm
Proportioning 1% 1% 3% 3%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I7
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
“Minuteman II” Foam Hose Reel Station
with Low Flow Hydro-Foam™ Monitor

Description:
Similar to the standard “Minuteman Hose Reel Station“, but with the added
advantage of pre-plumbed self educting 150/225 gpm Hydro-Foam™ Monitor Nozzle.
Enables the fire-fighter to knock down the fire from a distance prior to committing
via the hoseline. Monitor and hoseline can be used separately or simultaneously with
foam or water. System is equipped with a 2” Spectrum “Mini-Monitor” with Small
Body Hydro-Foam™ Nozzle. System proportions at 1% and/or 3%. Features a
built-in foam concentrate storage tank and a 60 gpm (or 95 gpm) 1% (or 3%) foam
eductor with water bypass. Includes a 60 gallon stainless steel foam concentrate stor-
age tank, complete with: pressure/vacuum vent; 6” fill opening, capped .75” drain
plug; lifting eyes; rigid concentrate pick-up line to tank bottom. Continuous flow
hose reel is equipped with 100 feet of 1.5” hard rubber hose and a constant flow
60 gpm (or 95 gpm) fog/straight stream nozzle. Equipped with brass water inlet manifold.
Red polyurethane paint finish.

Model # 150/601 150/951 150/603 150/953 225/601 225/951 225/603 225/953


Handline Flow 60gpm 95gpm 60gpm 95gpm 60gpm 95gpm 60gpm 95gpm
@150PSI
Monitor Flow 150 150 150 150 225 225 225 225
@100PSI
Proportioning 1% 1% 3% 3% 1% 1% 3% 3%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I8
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
“Minuteman III” Foam Hose Reel Station
with 3” Hydro-Foam™ Monitor

Description:
Similar to the standard “Minuteman Hose Reel Station“, but with
the added advantage of a pre-plumbed self educting 350/500 gpm Hydro-
Foam™ Monitor Nozzle. Enables the fire-fighter to knock down the fire
from a distance prior to committing via the hoseline. Monitor and hoseline
can be used separately or simultaneously with foam or water. System is
equipped with a 3” monitor with Hydro-Foam™ Nozzle. System propor-
tions at 1% and/or 3%. Features a built-in foam concentrate storage tank
and a 60 gpm (or 95 gpm) foam eductor with water bypass. Includes a
60 gallon stainless steel foam concentrate storage tank, complete with:
pressure/vacuum vent; 6” fill opening, capped .75” drain plug; lifting eyes;
rigid concentrate pick-up line to tank bottom. Continuous flow hose reel is
equipped with 100 feet of 1.5” hard rubber hose and a constant flow 60 gpm
(or 95 gpm) fog/straight stream nozzle. Equipped with brass water inlet
manifold. Red polyurethane paint finish.

3” MONITOR

Monitor Shut Off Valve

56”
Water By-Pass Valve
19”

Model # 350/601 350/951 350/603 350/953 500/601 500/951 500/603 500/953


Handline Flow 60gpm 95gpm 60gpm 95gpm 60gpm 95gpm 60gpm 95gpm
@150PSI
Monitor Flow 350 350 350 350 500 500 500 500
@100PSI
Proportioning 1% 1% 3% 3% 1% 1% 3% 3%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I9
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
Foam Hose Reel Station with 55 Gallon ThunderStorm™ ATC 1 x 3 AR/AFFF Foam Drum

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I10
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
Foam Hose Reel Station
with Medium Flow Hydro-Foam™ Monitor/Nozzle &
55 Gallon ThunderStorm™ ATC 1 x 3 AR/AFFF Foam Drum

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I11
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
Continuous Flow Hose Reel Stations

Description:
Spectrum Continuous Flow Hose Reel Stations provide instant, single-per-
son operation of fire fighting hose streams. Only the amount of hose required
is unreeled, providing a quicker and potentially safer fire prevention/suppression
operation. Continuous Flow Hose Reels are designed for use by trained fire per-
sonnel and are typically installed in areas that require supplemental (foam/water)
fire protection for: covering small flammable liquid spills; initial intervention fire
fighting; or “mopping up” after flame knockdown. Station components include:
continuous flow reel; booster hose; handline AFFF (water) nozzle.

Continuous Flow Hose Reel


Carbon steel construction. Manual wind with ductile iron “straight-in” swivel inlet connection and quick release brake.
Finished with red polyurethane.

Booster Hose
High quality hose for either water or foam solution service. Rigid mandrel construction produces a reinforced, round,
non-collapsible hose, providing efficient flow, yet also the flexibility required for proper handling during emergencies.
Includes cast brass, rocker lug expansion ring couplings.

I.D. 1.5 Min Bend Radius 8.5”


Maximum W.P. 150 psi Tube Black EPDM Rubber
Pressure Safety Factor 4:1 Cover Red EPDM Rubber
Wrapped Impression
O.D. 1.98” Reinforcement High Tensile Textile Tire
Cord Piles
Approx. Weight 81 lb. per 100ft. Temp Range -40º to 180º F

AFFF (Water) Nozzle


Industrial grade fog/straight stream nozzle. Cast Brass construction. U.L. listed for both Class A & Class B fires. Rated
60 gpm @ 100 psi, narrow fog pattern. Includes twist shut-off (not to replace valve on hose reel inlet).

Model No Hose A B C D E F G H
Capacity
BHR 1.5-100 100’ 25 26.5 20 11 30 12 27 14
BHR 1.5-200 200’ 25 26.5 34 11 44 12 41 14

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I12
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
Hose Reel Foam Station-Bladder Tank Style - 40 Gallon

Description:
The Bladder Tank Handline Hose Reel Foam System provides versatile, initial
fire intervention and can easily be operated by one person. Foam System requires no
external power source, other than a pressurized water source. The system consists of
the following components:
PRESSURE VESSEL- Bladder Type ASME carbon steel, 200 psi w.p. pressure
vessel, 40 gallon nominal capacity. Mounted on carbon steel support saddles.
INTERNAL BLADDER- Buna-N nylon impregnated, mullen burst pressure of
800 psi. Body seams are vulcanized with 1” overlap. Bladder outlets are one piece
molded rubber (vulcanized to bladder body).
PROPORTIONER- 2,” (1% or 3%) threaded ratio controller, cast bras
construction.
CONTINUOUS FLOW HOSE REEL- Carbon steel construction with rim
rewind and hand brake. Booster hose 1.5” x 100 ft. coupled 1.5” M/F NH brass
AFFF non-air aspirating brass nozzle (K-Factor=6) with full fog to straight stream
adjustment.
PIPE, VALVES AND FITTINGS- in contact with foam concentrate are con-
structed of brass and bronze. Water inlet ball valve is constructed of cast bronze
body with stainless steel ball and teflon seat. Foam solution piping is schedule 40
carbon steel.
FINISH- one rust resistant prime coat. One finish coat of red polyurethane.

COMPONENTS:
1. 40 Gallon, 200 psi Bladder Tank
2. Proportioner
3. Rim rewind hose reel with 100’
of 1.5” hard rubber hose
4. Pressure relief valve
5. Concentrate shut-off valve
6. Concentrate fill plug
7. Water vent valve
8. Concentrate vent valve
9. Water drain valve

Approx. Foam
Model- Bladder Tank Nozzle Flow Duration Approximate
Proportioning
Foam Hose Reel Station @100 psi Weight
1% 3%
40 gallon tank 60 gpm 1% / 3% 66 minutes 22 minutes 300 lb.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I13
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
Quick Attack Foam Cart

Description:
More than a portable monitor, the Quick Attack foam cart can easily be
operated by one person. Ideal for spill fires in chemical plants and flammable
liquid storage areas. A single mobile unit can be used to protect several differ-
ent remote hazard areas. Unlike eductor style foam stations this unit operates
effectively and proportions foam even at low water inlet pressures, down to
75 psi. Foam stream projects from monitor approximately 50 ft. at 70 psi inlet
pressure (straight stream in still air). Equipped complete with: supply hose, 2”
x 100 ft. coupled 1.5” NH; brass Spectrum “Mini-Monitor;” pre-plumbed self-
educting brass Hydro-Foam™ Small Body Monitor Nozzle, rated 150 gpm or
225 gpm @ 100 psi inlet. Stainless steel 35 gallon capacity foam concentrate
storage tank is fitted with fill opening, pressure vacuum vent and drain valve.
15” semi-pneumatic wheels. Specify 1% and/or 3% proportioning. Red vinyl
Quick Attack cover is available as an option.

Model Nozzle rating GPM Approximate foam Proportioning


Quick Attack Foam Cart @100 psi duration in minutes
QA-150-1 150 7.7 1%
QA-150-3 150 3.85 3%
QA-225-1 225 5.2 1%
QA-225-3 225 7.6 3%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I14
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Product:
Oscillating Monitor Foam Station

Description:
A completely self contained foam storage, proportioning and delivery
system. Ideal for truck loading racks, process areas and marine terminals.
The Spectrum Model 4 Water Powered Oscillating Monitor is fitted with
a Hydro-Foam™ self-educting nozzle which draws foam concentrate
directly from the storage tank via a flexible pick-up tube with fire resis-
tant flexible sheathing. For higher flow applications the Spectrum Model
4 High Flow Oscillating Monitor is used in conjunction with a Ranger™
Series (Fixed K or constant pressure) Hydro-Foam™ Aluminum Nozzle.
1% or 3% fixed or selectable nozzle. 4” 150# ASA flange inlet. Tank trim
includes: 6” fill; pressure/vacuum vent; tank drain, capped; rigid PVC
concentrate pick-up tube to sloped tank bottom.

Model Foam Tank Nozzle Flow Approx Foam Model 4 Nozzle Size &
(gallons) GPM @ 100 psi Duration/ minutes Oscillating Material
1% 3% Monitor
OFS-110-350 110 350 30 10 Medium Flow Medium Body, Brass
OFS-165-350 165 350 45 15 Medium Flow Medium Body, Brass
OFS-220-350 220 350 63 21 Medium Flow Medium Body, Brass
OFS-330-350 330 350 93 31 Medium Flow Medium Body, Brass
OFS-110-500 110 500 21 7 Medium Flow Medium Body, Brass
OFS-165-500 165 500 33 11 Medium Flow Medium Body, Brass
OFS-220-500 220 500 44 14 Medium Flow Medium Body, Brass
OFS-330-500 330 500 66 22 Medium Flow Medium Body, Brass
OFS-165-700 165 700 22 7 Medium Flow Medium Body, Brass
OFS-220-700 220 700 31 10 Medium Flow Medium Body, Brass
OFS-330-700 330 700 47 15 Medium Flow Medium Body, Brass
OFS-220-1000 220 1000 22 7 High Flow Ranger™, Aluminum
OFS-330-1000 330 1000 33 11 High Flow Ranger™, Aluminum
OFS-220-1250 220 1250 17 6 High Flow Ranger™, Aluminum
OFS-330-1250 330 1250 26 9 High Flow Ranger™, Aluminum
OFS-220-1500 220 1500 15 5 High Flow Ranger™, Aluminum
OFS-330-1500 330 1500 22 7 High Flow Ranger™, Aluminum

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I15
www.williamsfire.com

Self Contained Foam Systems


foam stations

foam stations
Oscillating Monitor Foam Station

BILL OF MATERIALS
No. Req’d Description
1 1 6” FOAM FILL
2 1 FOAM PICK-UP TUBE
3 1 4FT. FIRE RESISTANT FOAM PICK-UP HOSE
4 1 4”-150# R.F. FLANGE-WATER INLET
5 1 SPECTRUM OSCILLATING MONITOR, MODEL 4
6 1 ATMOSPHERIC AFFF TANK (C.S. OR S.S.)
7 1 DRAIN, PLUGGED
8 1 STANDARD RED ENAMEL FINISH
9 1 HYDRO-FOAM™ SELF EDUCTING NOZZLE
10 1 .75” PRESSURE RELIEF VENT

TANK DATA Hydro-Foam™ NOZZLE DATA


GALLON A B C D E Medium Body Brass “Ranger™” Aluminum Fixed K
110 25 20 24 5.75” 48 350 GPM @ 100PSIG 1000 GPM @ 100PSIG*
165 37 20 24 5.75” 48
500 GPM @ 100PSIG 1250 GPM @ 100PSIG*
220 48 21 25 5.75” 48
700 GPM @ 100PSIG 1500 GPM @ 100PSIG*
330 48 34 36 16.75” 48

*Oscillation limited to 90˚ ARC

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
I16
www.williamsfire.com

FOAM PROPORTIONING & LOOSE EQUIPMENT

foam proportioning / loose equipment


foam proportioning / loose equipment

SECTION INDEX

Williams’ “High Head” Through-the-Pump 1500 Portable Foam System.............................................................. J2

Williams’ Pressure Reducing Valve (WPRV/3, 3P, 4 & 4P)............................................................................................. J3

Tank Farm Fire Fighting Foam System..................................................................................................................................... J4

Jet Ratio Controllers...................................................................................................................................................................J5-J6

95 gpm Liquid Eductor................................................................................................................................................ J7

Spectrum Inline Eductors..............................................................................................................................................................J8

Spectrum “Double Action” By-Pass Eductor.........................................................................................................................J9

PKW Dry Chemical Manifold Typoical Layouts.................................................................................................................J10

Manifolds for Hydro-Chem™ Systems...............................................................................................................................J11

Typical Hose Lay For Hydro-Chem™ Trailer mount Systems.................................................................... J12

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J1
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product
Williams’ “High Head” Through-the-Pump
1500 Portable Foam System

Description:
The Williams High Head Through-the-Pump 1500 Portable Foam
System was designed to turn any pumper into a foam producing device. This
unit will proportion 3% foam solution up to 1500 GPM. It can work against
hydrant pressure up to 50 PSI with only 150 PSI discharge pressure. This
economical system is easy to use and is completely water driven; there are no
pumps or parts to maintain. Can’t get the foam to the pump? Not a problem!
The WTTP was designed to proportion foam from remote locations.

FEATURES:
• Operates against 33% Pump Suction Pressure.
(Example: Master Pressure @150 PSI, Suction Pressure @ 50 PSI)
• Proportions Class “B” Foam up to 1500 GPM at 3%.
• Proportions Class “B” Foam up to 750 GPM at 6%.
• Positive Shut-Off on Metering Valve.
• Requires no maintenance.
• Portable.
• Water Powered.
• Remote Proportioning Capabilities.
• Check Valve Prevents Water from “Back Flowing“
into Concentrate Source.

System Includes:
• Base Unit with Jet Pump & Metering Valve.
• 2.0” Clear Concentrate Pick-Up Hose.
• 2.0” Valved Drum Stinger. ThunderStorm

AFFF/ATC

MATERIALS OF CONSTRUCTION:
• Brass with Stainless Steel Trim.
Notes:
1. The following table is based on 150 psig operating pressure at the jet pump inlet.
2. At 50 psi water pump inlet, maximum hose lay is 25 ft. of 3.0” hose.
3. For drafting operations or pressure below 10 psi, use the 10 psi numbers shown.

Maximum Hose Lay (ft) For Remote Proportioning Portable WATP 1500 System
PUMP INLET PRESSURE
Solution Rate 10 PSI 20 PSI 30 PSI 40 PSI
HOSE SIZE HOSE SIZE HOSE SIZE HOSE SIZE
1% 3% 6% 2.5” 3” 2.5” 3” 2.5” 3” 2.5” 3”

30 12 850 1700 625 1250 400 775 200 325

100 40 825 1675 600 1225 375 750 175 300

400 160 80 800 1625 575 1175 350 725 150 275

1000 400 200 750 1500 525 1050 325 650 125 250

2000 750 375 650 1325 475 950 300 600 100 225

4000 1500 750 525 1050 375 775 250 475 75 200

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J2
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product:
Williams’ Pressure Reducing Valve
(WPRV/3, 3P, 4 & 4P)

Description:
Maintains constant pre-set inlet pressure for use in conjunc-
tion with the Williams “High Head” Through/Around The Pump
(or comparable) foam systems. Allows any firewater pump to pro-
duce suction side foam at virtually ANY positive inlet pressure.
As such, the WPRV eliminates need for operator intervention to
adjust intake gate valves due to suction pressure fluctuations as a
result of changes in pump discharge flow. Thus, the added burden
of assuring a maximum pump intake pressure (based on pump
discharge pressure) associated with traditional suction side foam
systems simply goes away.

Additional Applications:
Got a CAFS or Balanced Pressure system? The WPRV can provide reduced pump inlet pressures to allow increased
engine/PTO speed to maintain higher compressor or foam pump output when operating with positive pump inlet pressures.
Installed within a discharge line, the WPRV maintains a preset pressure for hand lines or ground monitors independent of
higher pump discharge pressures.

Features:
3 Modes of Operation:
1. AUTOMATIC – Controls pre-set pressure from 15-115 PSI
2. OPEN – Full flow to rated capacity
WPRV/3 — 500 GPM w/ 7 PSI drop
WPRV/4 — 1500 GPM w/ 20 PSI drop
3. CLOSED — Bubble tight shut off
• NFPA 1901, 14-6 COMPLIANT — Exclusive WPRV pilot control also provides bubble tight shut off to comply with
NFPA 1901, 19-3.6, TIA 99-1 preventing foam solution back flow into a potable (hydrant system) water supply
• PRESSURE RATINGS — 230 PSI Max. — 20 PSI Min. (Prevents reducing hydrant system pressures below 20 PSI)
• INLET/OUTLET — WPRV/3: 2.5” NST; WPRV/4: 5” Storz

Options:
WPRV/3 & 3P (Portable)
• “In-Truck” installation with panel mount control valve, standard 2.5” (F)NST swivel inlet w/ strainer and bleeder port
• 3” (F) NST inlet w/strainer/outlet
• 4” Storz inlet w/strainer/outlet WPRV/4 & 4P (Portable)
• “In-Truck” installation with panel mount control valve, standard 5” Storz inlet w/strainer, adjustable intake relief,
bleeder port and mounting hardware
• Inlet intake relief valve & bleeder (4P)
• 4” Storz inlet w/strainer/outlet
• 6” (F)NST swivel outlet for direct mounting to pump intakes
• Inlet/outlet pressure gauges
• Carrying handle
• 5” LDH X 10’ Long with 5” Storz couplings (200 PSI operating pressure)

Materials of Construction:
• WPRV/3 & 3P – Epoxy coated cast iron w/brass and stainless steel trim
• WPRV/4 & 4P – Epoxy coated & anodized aluminum w/brass and stainless steel trim

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J3
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product
Tank Farm Fire Fighting Foam System

“Old Style” 2 x 6 Gun JRCP Hose Lay Comparison


Flow Solution Jet # of Jet 2.0” Hose 2.50” Hose 3.0” Hose
Rate % Size lays Lay (ft) Time (min) Lay (ft) Time (min) Lay (ft) Time (min)
6,000 1 2 1 N/A N/A 350 1.0 750 2.8
6,000 1 1.5 2 440 1.4 1,300 6.1 2,550 17.4
6,000 3 2 3 N/A N/A 75 0.3 150 0.6

Ambassador JRCP Hose Lay Comparison


Flow Solution Jet # of Jet 2.0” Hose 2.50” Hose 3.0” Hose
Rate % Size lays Lay (ft) Time (min) Lay (ft) Time (min) Lay (ft) Time (min)
6,000 1 2 1 N/A N/A 350 1.0 750 2.7
6,000 1 1.5 2 434 1.3 1,250 6.0 2,550 17.2
6,000 3 2 3 N/A N/A 150 0.5 300 1.2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J4
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product:
Jet Ratio Controllers (Jet Pumps)

Description:
Utilizing a small amount of water, this high efficiency ven-
turi-type device moves foam concentrate from a remote storage
location to a matched Hydro-Foam™ nozzle. This all-hydraulic
system dramatically simplifies and improves the logistics of
moving the high quantities of foam concentrate required to
extinguish a large flammable liquid fire. Foam concentrate is
delivered from the Jet Ratio Controller to a matched Hydro-
Foam™ nozzle via fire hose. Depending on nozzle and hose
size, as well as the percentage of foam mixed (1% or 3%), the
distance between the foam supply and Hydro-Foam™ nozzle
can be up to 2,500 feet.

Jet Ratio Controllers are supplied in conjunction with matched Hydro-Foam™ nozzles. Foam concentrate inlet on
matched nozzle can be provided with 8 ft. of reinforced clear plastic hose with PVC shut-off valve, and/or metering valve
“stinger”. This configuration allows foam concentrate to be drawn directly from a foam concentrate drum and then delivered
efficiently to the nozzle via fire hose.

Jet Ratio Controllers are provided with connections at three ports, designated as “inlet,” “discharge” and “suction.” Inlet
(female swivel) and discharge (rigid male) has National Hose thread (NST, NH) connections with NPT (M) connection for
the concentrate inlet port. Foam concentrate inlet is furnished with standard drum kit, which consists of flexible suction hose,
rigid PVC “Stinger” pipe and shutoff valve. Jet Ratio Controller body is all brass construction. “H” series jet ratio controllers
are available, on special order, for elevated nozzles, or other high back pressure applications.

Typical Schematic

ThunderStorm®
AFFF/ATC

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J5
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

1.5”
INLET

TYPICAL SCHEMATIC

ThunderStorm®

AFFF/ATC

MODEL 3% Flow Match 1% DISCHARGE “A” SUCTION “B” LENGTH “C”


1.5JP24 750 GPM 2000 gpm 1.5” 1.5” 12.375”
1.5JP30 1000 GPM 2500 gpm 1.5” 1.5” 12.375”
2.0JP60 2000 GPM 5000 gpm 2.5” 2” 15.5”

NOTE: 6% APPLICATIONS AVAILABLE UPON REQUEST

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J6
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product:
95 gpm Liquid Eductor

Description:
The Elkhart 242-95 Eductor is a device used for educt-
ing a liquid concentrate solution into the water stream of
1-1/2” coupled fire hose lines.
The Eductor is constructed of Armor-Lyte ™ composite
material with stainless steel components for resilience and
durability. Armor-Lyte ™ is impervious to the corrosion
caused by high concentrate detergents, salt water and most
chemicals.
Each eductor comes equipped with a 1-1/2” “F” NH
female swivel connector input, a 1-1/2” “M” NH male outlet
and a 3/4” male Garden Hose Thread inlet for the concen-
trate pick-up hose.
The 242-95 Eductor is factory calibrated for pump flow rates of 95gpm (356 lt/m). The Eductor comes complete with
three different checkvalves for three different concentrate eduction rates. When attached, the Black checkvalve will educt at
a 0.5% rate, the Purple checkvalve will educt at a 1% rate and the Green checkvalve is for educting at a 3% rate.
To switch checkvalves on the eductor unit, gently grasp the checkvalve body with pliers or vise grips and unscrew.
Carefully screw alternate checkvalve into eductor body, thread to “hand-tight”. There is no need to over tighten.
The 242-95 Eductor can be used as either an “End-of-the-Line” or as a “Pump Mounted” System. The eductor is designed
for a nominal operating pressure of between 75 and 150 psi. If proportioning 3%, the 242-95s are restricted to a maximum
hose length of 150 feet between the eductor and nozzle. However, at ½% and 1% solution rates, the maximum hose lay with
1.50”ID fire hose goes to 200 feet when used with a 95+gpm nozzle.

The Eductor comes complete with


three different checkvalves for three
different concentrate eduction rates.

*Armor-Lyte™ is a registered trademark of


Williams Fire and Hazard Control, Inc®
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J7
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product:
Spectrum Inline Eductors

Description:
Spectrum Inline Foam Eductors provide the simplest and
most economical method of introducing a controlled flow of
foam concentrate into a pressurized water stream. As opposed to
“Hydro-Foam™ Technology”, (which is used in conjunction with
master stream nozzles) these “Venturi-Type” foam proportioners
are designed to be used in conjunction with a matched constant
flow end-of-line device (nozzle), where adequate water pressure
is available. Inline foam eductors are capable of operating at inlet
pressures as low as 70 psi, but in most cases adequate residual fire
fighting pressure at the nozzle requires that the eductor inlet pres-
sure be at least 100 psi, or greater.

Spectrum Inline Eductors are rated to flow 60, 95, or 125 gpm @ 150 psi inlet. Nominal flow rates at other inlet pres-
sures are listed below. Eductor outlet pressure is approximately 65% of inlet pressure. Eductor components, including body,
venturi jet and metering orifice are constructed of corrosion-resistant brass.

Standard water inlet - NH (F) swivel. Foam solution discharge - NH (M). Complete with clear pvc concentrate pick-up
hose with slotted brass “stinger”; 1% or 3% fixed orifice; ball check valve.

RIGID

Model Nominal Flow Nominal Flow Nominal Proportioning


@100 PSI @125 PSI @150 PSI
1.5” -60 gpm 49 gpm 55 gpm 60 gpm 1% or 3%
1.5” -95 gpm 78 gpm 87 gpm 95 gpm 1% or 3%
1.5” -125 gpm 102 gpm 114 gpm 125 gpm 1% or 3%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J8
www.williamsfire.com

Foam Proportioning & Loose Equipment

foam proportioning / loose equipment


foam proportioning / loose equipment

Product:
Spectrum “Double Action” By-Pass Eductor

Description:
The Spectrum “Double Action” By-Pass Foam Eductor pro-
vides the versatility of a full-flow water by-pass foam proportioner
in conjunction with the simplicity and reduced weight of a stan-
dard, single waterway inline eductor. This specialty by-pass type
foam venturi transforms any 1.5” handline into a foam proportion-
ing system. Three flow rates are available: 60 gpm; 95 gpm; 125
gpm. Flows are based on 200 psi inlet pressure. The eductor will
proportion foam at lower inlet pressures, provided that discharge
pressure is not excessive. Positive shut-off metering allows foam
proportioning to be adjusted and set from 0.5% to 3%. Body is
constructed of durable 6061 - T6 (black) anodized aluminum.

In operation, foam is produced by simply installing the system in the hose line, emersing the concentrate pickup tube
into an adequate supply of ThunderStorm® AFFF foam concentrate and adjusting the eductor to the “foam” position. When
foam application is no longer needed, there is no need to remove the eductor for application of water only. This conversion
is easily accomplished by simply rotating the foam control sleeve to the “water” setting. The result is an enlarged waterway
which allows for water only application.

Other Features Include:


• Positive Shutoff Metering Valve.
• Integral Concentrate Ball Check Valve.
• Clear Plastic Concentrate Pick Up Hose with Rigid “Stinger”.
• Lightweight, Compact Design (4 lbs., nominal).

Double Action Nominal Flow K-Factor Inlet Discharge Proportioning


Eductor @200 PSi Range
60 gpm 60 gpm 4.25 1.5 NH (F) Swivel 1.5” NH (M) 0.5%-6%
95 gpm 95 gpm 6.72 1.5 NH (F) Swivel 1.5” NH (M) 0.5%-6%
125 gpm 125 gpm 8.84 1.5 NH (F) Swivel 1.5” NH (M) 0.5%-6%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J9
www.williamsfire.com

“PKW™” Dry Chemical Delivery Manifold —


Typical Layouts

foam proportioning / loose equipment


foam proportioning / loose equipment

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J10
www.williamsfire.com

Hydro-Chem™ Technology

foam proportioning / loose equipment


foam proportioning / loose equipment

Manifolds for Hydro-Chem™ Systems

Dry Chemical Manifiold - 4 Inlets

Dry Chemical Manifiold - 6 Inlets

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J11
www.williamsfire.com

Hydro-Chem™ Technology

foam proportioning / loose equipment


foam proportioning / loose equipment

Typical Hose Lay For Hydro-Chem™ Trailer mount Systems

1000 GPM Hose Layout

Patriot II Hose Layout

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
J12
www.williamsfire.com

PETROLEUM STORAGE TANK FIRE PROTECTION


storage tank fire protection

storage tank fire protection


SECTION INDEX

Foam Application Method: Fixed Surface Systems — (Design Reference NFPA 11)...................................... K2

Fixed, Full Surface Foam Application...............................................................................................................................K3-K4

Foam Chambers............................................................................................................................................................................K5-K7

Supplementary Foam Application in Diked Area - Foam/Water Monitors..........................................................K8

Foam Application Method: Seal Area Protection — (Design Reference NFPA 11)...................................K9-K11

Standard LW Foam Makers - Typical Installations........................................................................................................K12

Spectrum LW9/WSDB, Foam Maker with Wind Shield/Discharge Board . .......................................................K13

Standard LW Foam Makers......................................................................................................................................................... K14

Foam Application Method: Subsurface Foam Injection -  (Design Reference NFPA 11).................. K15-K22

Supplementary Foam Application in Diked Area - Foam/Water Monitors....................................................... K23

High Back Pressure Foam Makers / Medium Flow - Brass........................................................................................K24

High Back Pressure Foam Makers / High Flow - Aluminum..................................................................................... K25

High Back Pressure Foam Makers / Self Educting........................................................................................................ K26

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K1
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Application Method: Fixed Surface Systems
(Design Reference NFPA 11)

General:
Fixed Surface Application Systems provide a potentially effective method of foam fire protection for vertical, atmospheric
cone roof, internal floating roof, or open floating roof storage tanks containing hydrocarbon or alcohol (water miscible) liquids.
For this application, discharge outlets are commonly referred to as “NFPA 11, Type II foam Chambers”. Foam Chambers can
be sized and installed to provide either full surface fire protection, or seal protection only, when installed on floating roof tanks
with foam dams.

In general, ThunderStorm® solution is proportioned and delivered into the system inlet piping which supplies one or more
topside-mounted foam chambers. Upon entering the foam chamber, foam solution is then: introduced at the designed applica-
tion rate through a calculated orifice and frangible vapor seal; aerated and expanded a nominal 8:1 with air; directed into the tank
through a flanged penetration; deflected down the interior tank shell where it reaches the fuel surface; and (ultimately) delivered
across the burning liquid surface to extinguish the fire.

FUEL STORAGE TANKS- Basic Configurations

Cone Roof Tank Covered Floating Open Floating


Roof Tank Roof Tank

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K2
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Fixed, Full Surface Foam Application

Design Considerations

• Minimum Application Rates


To determine the minimum application rate, use the following calculations (where tank diameter = D).

Minimum Application Rate =

(D x D) x 0.785 X Min. Application Density


When Application Density is 0.1 Gpm per Sq. Ft:

(D x D) x 0.785 X 0.1

Example for an 80’ Diameter Crude Oil tank:

80 x 80 x 0.785 x 0.1 = 503 gpm minimum application rate.

When Application Density is 0.16 Gpm per Sq. Ft.:

(D x D) x 0.785 X 0.16

Example for an 80’ Diameter Ethanol tank:

80 x 80 x 0.785 x 0.16= 804 gpm minimum application rate.

• Minimum Foam Application Durations.


Combustible liquids (flash point > 100 degree F.)- 30 minutes
Flammable liquids (flash point < 100 degrees F.)- 55 minutes
Crude oils- 55 minutes
Alcohols- 55 minutes

NFPA 11 Recommendation for Supplementary Foam Application in Diked Area -


(Hose Streams)*.

Note:
NFPA 11 recommends the following minimum rates for “supplementary foam hose streams” to protect the diked area
from small spills or fires. Minimum flow rates are based on 50 gpm per handline.

Hose Stream Operating Times


Number of Hose Streams Simultaneous operation of required minimum
number of hose streams discharging
Diameter of Minimum No. of at a rate of 50 gpm.
Largest Tank Hose Streams
Diameter of Minimum Operating
up to 65’ 1 Largest tank Time
65’ to 120’ 2 up to 35’ 10 minutes
over 120’ 3 35’ to 95’ 20 minutes
over 95’ 30 minutes

* Refer to Page K9 for Williams’ recommendations regarding Dike Protection.


01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K3
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Fixed, Full Surface Foam Application

Design Considerations

• Minimum Foam Concentration Inventories


Calculation for minimum foam inventory:
πr2 x Application Rate x % of Proportioning x Application Duration +
Supplemental Dike Protection (As per NFPA 11)

Example for an 80’ Diameter Tank in Crude Oil Service:


(Foam Concentrate Inventory is ThunderStorm® ATC 1 x 3 AR/AFFF @ 1%)

40 x 40 x 3.14 x 0.1 x 0.01 x 55 + 60 = 889 gallons


Add for 100% Reserve Inventory (if required) + 889 gallons

Total Minimum Foam Inventory 1,778 gallons

Example for a 120’ diameter Tank in Ethanol Service:


(Foam Concentrate Inventory is ThunderStorm® ATC 1 x 3 AR/AFFF @ 3%)

60 x 60 x 3.14 x 0.16 x 0.03 x 55 + 135 = 6,104 gallons


Add for 100% Reserve Inventory (if required) + 6,104 gallons

Total Minimum Foam Inventory 12,208 gallons

• Discharge Outlets (Foam Chambers)

Minimum number of topside foam discharge outlets (chambers for full surface application is listed below). Where two
or more outlets are used the foam chambers should be spaced equally around the tank and each should be designed to deliver
foam at approximately the same discharge rate. Foam chambers should be installed at the top of the tank shell, located above
the product’s highest level. Each chamber should be secured to the tank shell in a way that minimizes the possibility of dam-
age, in the event that the tank’s roof is displaced by a vapor-air explosion. Each chamber should be equipped with a low
pressure frangible vapor seal, as well as a suitable means for inspection.

Tank Diameter Minimum No. of


Discharge Outlets
up to 80’ 1
> 80’-120’ 2
> 120’-140’ 3
> 140’-160’ 4
> 160’-180’ 5
> 180’-200’ 6

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K4
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Product:
Foam Chambers

Description:
Spectrum Foam Chambers are discharge outlets defined by NFPA 11 as “Type II”
top-side application devices. They are designed to meter foam flow, then gently expand
and deliver foam directly onto the surface of a flammable or combustible liquid. Foam
chambers are installed on the vertical wall of fuel storage tanks, above the product’s
highest liquid level. Flow rates are sized for full surface application, or for protection
of the annular seal area (only) of open floating roof tanks. Foam solution supply pip-
ing to the chamber can either be connected to a “fixed” foam storage and proportioning
system, or tied into a dry pipe, “semi-fixed” system which receives foam solution from
a mobile foam apparatus.

In operation, foam solution passes through an orifice plate which is sized to deliver
the required flow rate at a specific inlet pressure. The metered flow of foam solution is
then introduced into the foam maker, where it is aerated. The foam chamber inlet pip-
ing is fitted with a frangible vapor seal, which is designed to rupture at a predetermined
pressure. The aerated foam solution enters the foam expansion chamber body, where additional expansion occurs, and the
velocity of the foam is reduced. As the foam leaves the chamber body, it passes through the tank shell, and then impacts a
foam deflector, which directs the foam down the tank wall and ultimately onto the fuel surface.

The foam chamber is accessible for inspection and service through a removable inspection hatch which is located on top
of the chamber body. Foam deflectors are available in either solid, split, or shallow configurations. Solid style deflectors
allow for installation when the shell is accessible from both inside and outside the tank (new tank installations). Split-style
deflectors allow for installation when the shell is only accessible from outside the tank (existing tank installations). Standard
finish, primed, with red epoxy exterior coating.

Model Nominal Flow Inlet Flange Discharge Flange


@ 100 psi
LW-9 40-150 gpm 2.5” 4”
LW-17 100-280 gpm 3” 6”
LW-30 190-600 gpm 4” 8”
LW-55 400-1000 gpm 6” 10”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K5
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Chamber Exploded View

Materials of Construction
Body, Maker & Flanges Carbon Steel
Retainer Hatch Stainless Steel & Brass
Orifice Plate Stainless Steel
Retainer, Vapor Seal Brass
Gaskets Buna-N

A B C
LW-9 7.5 .75” 4.75”
LW-17 9.5” .875” 6.625”
LW-30 11.75” .875” 8.75”
LW-55 14.25” 1” 10.75”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K6
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Chamber Schematic and Data

Foam Chamber Dimensional Data

MODEL A B C D E F G H I J WEIGHT
LW-9 28.1875” 8.125” 9.8125” 7” 2.5” 2.75” 8” 8” 12” 8” 80 LBS.
LW-17 32.25” 9.125” 10.625” 9” 3” 4.125” 9.5” 12” 18” 10” 130 LBS.
LW-30 34.25” 10.875” 10.6875” 10” 4” 5.5” 11” 16” 24” 12” 200 LBS.
LW-55 42” 12” 13” 12” 6” 6.5” 12” 20” 30” 16” 350 LBS.

Required Ordering Information

Foam Chamber Model No. can be determined by providing the following:

1. Product in tank
2. Tank configuration
3. Tank diameter
4. Full surface or seal protection
5. Height of Foam Dam (Seal protection)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K7
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Supplementary Foam Application in Diked Area - Foam/Water Monitors

ThunderStorm®

AFFF/ATC

Foam/Water Monitors provide the following advantages over (as well as exceed) the recommen-
dations of NFPA 11 for (50 gpm) supplemental hoselines.

Versatility
Firewater monitors are usually installed, or otherwise made available for exposure protection, as well as tank cooling in
and around the tank farm. When employed for water application, they can also serve a dual purpose and be used for applying
foam for vapor suppression and/or spill fire protection. Firewater monitors are easily converted to this dual “foam/water”
application through the use of a separate/dedicated foam reservoir and a Hydro-Foam™ Nozzle installed on each monitor. As
opposed to a central foam system, which charges a common line with foam solution, this configuration provides the versatility
of allowing operators to selectively use each monitor for either foam or water.

Fire Fighting Capability


Hydrocarbon spill fires require a minimum nominal foam application density of 0.1 gpm per sq. ft. Therefore, a 50 gpm
handline has the capability of controlling and suppressing approximately 500 sq. ft. of flame surface area. Scaled up, a 500
(750, 1,000) gpm foam water monitor has the capability of controlling and suppressing 10 (15, 20) times the flame surface
area versus that of a 50 gpm handline nozzle.

Operator Safety
Monitors flowing between 500 gpm and 1,000 gpm have an effective range which is about 3-4 times farther than that of
a 50 gpm handline. This greater projection of foam or water translates proportionally into more safety for the operator. In
addition, when the monitor nozzle is adjusted to the “full fog” position the higher volume of foam or water provides propor-
tionally more cooling for the operator. Also, (as opposed to handlines) monitors can be set up and adjusted - then temporarily
left unattended, if necessary.

Foam/Water Management
Individual/dedicated foam reservoirs at each monitor eliminate the possibility of depleting a central foam storage tank, in
the event a single foam monitor is opened and then left unattended.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K8
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Application Method: Seal Area Protection
(Design Reference NFPA 11)

General:
Annular Seal Area Protection of Open Top Floating Roof Tanks. “Top of Seal” method with
foam dam, utilizing fixed discharge outlets (foam chambers).

• Design Criteria - Foam Dams:


Foam dams should be designed and constructed so that the expanded foam is retained between the dam and the tank shell,
in sufficient quantities to adequately cover the seal area. Minimum recommended height of the foam dam is 12” , and should
extend upward to a minimum of 2” above the secondary seal. Spacing between the foam dam and the tank shell should be a
minimum of 12” and a maximum of 24”. The foam dam bottom should be slotted to allow drainage of rain water. However,
the slots should also be designed and sized to prevent excessive loss of foam. Maximum recommended height of the slots is
.375”. Slots should be sized on the basis of 0.4 sq. inches of slot area per sq. ft. of dam area.

• Maximum Spacing of Foam Chambers


Foam Chambers (Makers) are to be equally spaced around the tank per the following criteria:

Tanks with Foam Dams < 24” High - Maximum spacing is every 40 linear ft.
Tanks with Foam Dams 24” high or Greater- Maximum spacing is every 80 linear ft.

• Minimum Number of Foam Chambers

Calculation for Minimum Number of Foam Chambers (Makers)


Tank Circumference (π x D) / Maximum Spacing Between Devices

Example Calculation for an 120’ Diameter Tank with 24” High Foam Dams:

Tank Circumference Calculation (3.1416 x 120)


Tank Circumference = 377
Minimum Spacing of Discharge Devices = Every 80 ft.
Minimum Number of Discharge Devices = 377/80 or 4.713
Therefore Actual Number of Discharge Devices = 5

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K9
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Application Method: Seal Area Protection
(Design Reference NFPA 11)

• Area of Zone - Calculation of Seal Area


Example Calculation for a 120’ Diameter Tank:

(60 x 60) x 3.14 = 11,304 sq. ft.


(58 x 58) x 3.14 = 10,563 sq. ft.

11,304 - 10,563 = 741 sq. ft. , Area of Zone

• Minimum Application Density of Foam Solution is 0.3 gpm per Sq. Ft.

• Minimum Application Rate (gpm) -


Calculation for Minimum Application Rate =

Area of Zone x Minimum Application Density

Example Calculation for a 120’ Diameter Tank:

Area of Zone = 741 Sq. Ft.


Minimum Application Density = 0.3 Gpm per Sq. Ft.
Minimum Application Rate Calculation = 741 x 0.3
Minimum Application Rate = 223 Gpm

• Minimum Application Rate per Foam Chamber (Maker)


Calculation for Minimum Application Rate per Chamber =

Minimum Application Rate / Minimum No. of Foam Chambers

Example Calculation for an 120’ Diameter Tank:

Minimum Application Rate = 223 gpm


Minimum No. of Foam Chambers (Makers) =5
Minimum Application Rate Per Foam Chamber = 223/5 = 44.6 Gpm

• Minimum Foam system Application Duration is 20 Minutes


Minimum Foam Application into the Seal area is 20 minutes.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K10
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Application Method: Seal Area Protection
(Design Reference NFPA 11)

• NFPA Minimum recommendations for Supplementary Foam Application in


Diked Area - (Hose Streams)*

NFPA 11 recommends the following minimums for supplementary foam hose streams to protect the diked area from small
spills or fires. Minimum flow rates are based on 50 gpm per handline.

Hose Stream Operating Times


Number of Hose Streams Diameter of Minimum Operating
Diameter of Minimum No. of Largest Tank Time up to
Largest Tank Hose Streams 35’ 10 minutes
up to 65’ 1 35’ to 95’ 20 minutes
65’ to 120’ 2 over 95’ 30 minutes
over 120’ 3 Simultaneous operation of the required minimum
number of hose streams discharging at a rate of 50 gpm.

* Refer to page K9 for Williams’ recommendations regarding Dike Protection.

• Minimum Foam Concentrate Inventories


Calculation for Minimum Foam Inventory is (where tank diameter = D):
Minimum Foam Inventories =

(Seal Area) x (Application Density) x (% Proportioning) x (Application


Duration) + (Supplemental Dike Protection)

Example Calculation for a 120’ Diameter Tank in Gasoline Service:


(Foam Concentrate is 3% AFFF)

Seal Area = 741 Sq. ft.


Application Density = 0.3 Gpm per Sq. Ft.
Proportioning = 3%
Application Duration = 20 minutes
Supplemental Protection = Two Handlines @ 50 gpm for 30 minutes

741 x 0.3 x 0.03 x 20 = 134 gallons - Seal Protection (Foam Chambers) +


(50 +50) x 0.3 x 0.03 x 30 = 90 gallons - Supplemental Protection
Minimum Foam Concentrate Inventory = 224 gallons
Add for 100% Reserve inventory (if required) + 224 gallons
Total Minimum Foam Inventory 448 gallons

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K11
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Standard LW Foam Makers - Typical Installations

Foam Maker Details


Typical Storage Tank Protection

Typical Tank Dike Protection

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K12
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Product:
Spectrum LW9/WSDB, Foam Maker
with Wind Shield/Discharge Board

Description:
The Spectrum LW9/WSDB Foam Makers are inte-
grated systems providing NFPA 11 “Type II” foam appli-
cation to the seal area of open floating roof tanks. It is
designed to allow for installation without taking the tank
out of service. They are designed to meter foam flow,
then gently expand and deliver foam directly onto the
seal area surface of flammable or combustible liquids. Foam solution
supply piping to the system can either be connected to a “fixed” foam
storage and proportioning system, or tied into a dry pipe, “semi-fixed”
piping network, which receives and delivers foam solution from a
mobile fire apparatus.

In operation, foam solution passes through an orifice plate which


is sized to deliver the required flow rate at a specific inlet pressure.
The metered flow of foam solution enters the interior of the discharge
board, where additional aeration occurs as it impacts the deflector
plates and passes through a wired mesh discharge opening.

The entire unit can be installed to the top of the storage tank shell
without the need for welding, or any “hot work” by utilizing heavy duty galvanized mounting clamps secured with stainless
steel machine bolts and jam nuts. Constructed of galvanized carbon steel, with 304 stainless steel mesh screen and trim.

LW9/WSDB
Operating Inlet Pressures 75 - 125 psi
Min/Max Flows 25 - 100 gpm
K-Factor 2.5 - 10.0
Material of Construction Piping & Body - Galvanized Carbon Steel
Wire Mesh Screen & Deflector Trim - Stainless Steel

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K13
www.williamsfire.com

Foam Makers
storage tank fire protection

storage tank fire protection


Product:
Standard LW Foam Makers

Description:
Foam Makers are used to aerate foam solution “in-line” prior to
application into the hazard area. They are ideal for dike or rim seal
fire protection where low velocity foam streams are desired. In general,
standard foam makers should be installed within 10 ft. of foam applica-
tion points. Nominal foam expansion is from 5:1 to 8, depending on
the type of foam as well as the size and configuration of the discharge
piping and nozzle. Foam Makers are available in two basic configura-
tions - threaded and flanged. Flanged Foam Makers are available with
optional vapor seals.

Threaded Foam Maker

Flanged Foam Maker

Model Nominal flow A-Length Inlet Discharge Recommended Size,


@ 100 psi Foam Delivery Pipe
THREADED
LW 15D 10 to 40 gpm 16” 1.5” NPT (F) 1.25” NPT(M) 3”
LW 25D 40 to 140 gpm 20” 2.5” NPT (F) 2.5” NPT(M) 4”
FLANGED
LW-9D 30-150 gpm 24” 2.5” Flanged 2.5” Flanged 4”
LW-17D 100-280 gpm 30” 3” Flanged 3” Flanged 6”
LW-30D 175-600 gpm 36” 4” Flanged 4” Flanged 8”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K14
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Foam Application Method: Subsurface Foam Injection
(Design Reference NFPA 11)

General -
Subsurface injection is a potentially effective method of providing fixed (or semi-fixed) foam fire protection for vertical,
atmospheric cone roof storage tanks containing hydrocarbon liquids. In general, ThunderStorm® ATC™ solution is expanded
a nominal 4:1 with air and injected into the tank at its base through a High Back Pressure Foam Maker. The expanded foam is
delivered to the tank’s base by directing its flow either through an existing product line or through dedicated foam distribution
piping. In either case, the injection point(s) must be located above any potential water layer at the bottom of the tank.

Advantages of Subsurface Injection


Efficiency:
Expanded foam solution is delivered to the burning fuel surface with minimum exposure to heat and flame.

Survivability:
Piping and equipment is located at the tank’s base, in an area not as subject to damage from convected/conducted
heat, vapor-air explosion and/or detonation.

Product Surface Cooling:


Percolating foam bubbles rise to the hydrocarbon surface from the injection point(s) at the tank’s base. This pro-
cess tends to cycle cooler product to the surface which can assist in reducing heat and flame intensity.

Installation Versatility:
Certain subsurface systems can be installed using procedures that do not require taking the tank out of service.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K15
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection

Design Considerations

• Limitations:
Subsurface injection should not be used on:

• Floating Roof Tanks (as the primary system).


• Tanks containing water miscible (alcohol) type flammable/combustible fuels.
• Tanks containing Class 1A hydrocarbon flammable liquids
(i.e. those with a flash point < 73˚ F., and a boiling point < 80˚ F.)

• Minimum Application Density/Rate:


The minimum foam solution application density for subsurface injection is 0.1 gpm per sq. ft. To determine the minimum
application rate, use the following calculation (where tank diameter = D).

Minimum Application Rate =


(D x D) x 0.785 X 0.1

• Minimum Application Durations:

Combustible Liquids (flash point > 100˚ F.) - 30 minutes


Flammable Liquids (flash point < 100˚ F.) - 55 minutes
Crude Oils - 55 minutes

• NFPA 11 Recommendation for Supplementary Foam application in Diked Area - (Hose Streams) *.

NFPA11 recommends the following minimum rates for “supplementary foam hose streams” to protect the diked area from
small spills or fires. Minimum flow rates are based on 50 gpm per handline.

Hose Stream Operating Times


Number of Hose Streams
Simultaneous operation of the required minimum
Diameter of Minimum No. of number of hose streams discharging at a rate of 50 gpm.
Largest Tank Hose Streams
Diameter of Largest Tank Minimum Operating Time
up to 65’ 1
65’ to 120’ 2 up to 35’ 10 minutes
over 120’ 3 35’ to 95’ 20 minutes
over 95’ 30 minutes

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K16
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection

Design Considerations

• Minimum Foam Concentration Inventories


Calculation for minimum 3% foam inventory is (where D = tank diameter):

(D x D) x .785 X 0.1 x 0.3 x (Application Duration) + Supplemental Dike Protection

Example for an 80’ Diameter Tank in Crude Oil Service:


(Foam Inventory is 3% ThunderStorm® ATC™ )

80 x 80 x 0.785 x 0.1 x 0.03 x 55 + 60 = 889 gallons


Add for 100% Reserve Inventory (if required) + 889 gallons

Total Minimum Foam Inventory 1,778 gallons

• Expanded Foam Rates & Velocities

Maximum (expanded foam inlet velocities should not exceed 10


ft. per second (fps) for flammable liquids and 20 fps for combustible
liquids. To determine the expanded foam rate, use the minimum appli-
cation rate (established previously) and multiply by four (4), which is
the maximum anticipated foam expansion (4:1) through the high back
pressure foam maker. Refer to the adjacent chart to determine minimum
(schedule 40) pipe sizes.

Maximum Allowable Back Pressure

a) Maximum Allowable Back Pressure = 40% of Inlet Pressure.


When using Spectrum High Back Pressure Foam Makers, the total allowable system back pressure should not exceed
40% of foam solution inlet pressure or:

Maximum Allowable Back Pressure = Inlet Pressure x 0.4

Spectrum High Back Pressure Foam Makers are rated 150 psi (standard inlet pressure).

Therefore:

Maximum Allowable Back Pressure = 150 x 0.4


Maximum Allowable Back Pressure = 60 psi

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K17
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection

Design Considerations

• Maximum Allowable Back Pressure (cont’d.)

The maximum allowable back pressure increases (decreases) proportionally with the inlet pressure into the foam maker.
K Factors are provided in this catalog for each Spectrum High Back Pressure Foam Maker, or refer to the following formula
for determining the adjusted flow through the Foam Maker for pressures other than 150 PSI:

Example, HPB Foam Maker # HBFM - 250B @ 150 psi:



Standard Flow Rate = 250 gpm @ 150 psi.
K factor* = 20.4 *K Factor Calculation
Adjusted Inlet Pressure = 160 psi.
Flow = K x *P K= Flow/ P*
Flow = 20.4 x * 160 K = 250 / 150*
Flow = 20.4 x 12.65 K = 250/12.25 =
Flow = 258 gpm K = 20.4

b) Maximum Allowable Back Pressure < 40 % of -


(Maximum Friction Loss + Static Head Pressure of Stored Material)

To determine static head by using the adjacent chart, first locate the highest possible level of the product in the storage
tank, then locate the line representing the specific gravity of the stored product.

Specific Gravity

A = 1.00 (Water)
B = 0.90 (Oils)
C = 0.84 (Fuel Oil)
D = 0.72 (Gasoline)
E = 0.68 (Heptane)

• Back Pressure Calculation


Maximum Allowable Back Pressure < 40% of Inlet Pressure
Back Pressure (PSIG) < X + Static Head / 2.3

Maximum Allowable Back Pressure < 40% of Inlet Pressure

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K18
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection

Design Considerations

• Determining Expanded Foam Friction Loss in Pipe

Subtract the static head pressure (derived from chart in section B) from maximum allowable back pressure for the higher
back pressure foam maker. The remaining figure is the maximum allowable friction loss in pipe. Calculate the length of
total delivery pipe needed and establish a pipe size so that pressure drop in the system does not exceed the maximum allow-
able friction loss. Assume a 4:1 foam expansion rate for calculation purposes (flow rate x 4).

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K19
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection

Design Considerations

• Number of Discharge Outlets


Minimum number of subsurface foam dis- Tank Diameter Flash Point <100º Flash Point >100º
charge outlets are listed in the adjacent table up to 80’ 1 1
80’ - 120’ 2 1
120’ - 140’ 3 2
140’ - 160’ 4 2
160’ - 180’ 5 2
180’ - 200’ 6 3
over 200’ One outlet for each One outlet for each
additional 500’ sq.ft. additional 7500’ sq. ft.

• Configuration of Discharge Outlets


Where two or more outlets are required, they should be located so that the horizontal foam travel on the fuel surface
does not exceed approximately 80 ft. Each outlet should be sized to deliver foam at approximately the same flow rate. Foam
outlet(s) can either be connected directly to the tank shell, or can be supplied through a pipe manifold within the tank from a
single shell connection.

Typical Configurations


Pipe Manifold Configuration Tank Shell Configuration

2 Outlets

3 Outlets

4 Outlets

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K20
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection - Schematics

Typical Flow Diagrams

Dedicated Line - Foam Injection

Product Line Foam Injection


Single Inlet - Dual Outlet Manifold

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K21
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Subsurface Foam Injection -
Recommended Foam Piping Inlet Configurations

STRAIGHT IN

HORIZONTAL ELL

HORIZONTAL TEE

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K22
www.williamsfire.com

Storage Tank Protection


storage tank fire protection

storage tank fire protection


Supplementary Foam Application in Diked Area - Foam/Water Monitors

ThunderStorm®
AFFF/ATC

Foam/Water Monitors provide the following advantages over (as well as exceed) the recommen-
dations of NFPA 11 for (50 gpm) supplemental hoselines.

Versatility

Firewater monitors are usually installed, or otherwise made available for exposure protection, as well as tank cooling in
and around the tank farm. When employed for water application, they can also serve a dual purpose and be used for applying
foam for vapor suppression and/or spill fire protection. Firewater monitors are easily converted to this dual “foam/water”
application through the use of a separate/dedicated foam reservoir and a Hydro-Foam™ Nozzle installed on each monitor. As
opposed to a central foam system, which charges a common line with foam solution, this configuration provides the versatility
of allowing operators to selectively use each monitor for either foam or water.

Fire Fighting Capability

Hydrocarbon spill fires require a minimum nominal foam application density of 0.1 gpm per sq. ft. Therefore, a 50 gpm
handline has the capability of controlling and suppressing approximately 500 sq. ft. of flame surface area. Scaled up, a 500
(750, 1,000) gpm foam water monitor has the capability of controlling and suppressing 10 (15, 20) times the flame surface
area versus that of a 50 gpm handline nozzle.

Operator Safety
Monitors flowing between 500 gpm and 1,000 gpm have an effective range which is about 3-4 times farther than that of
a 50 gpm handline. This greater projection of foam or water translates proportionally into more safety for the operator. In
addition, when the monitor nozzle is adjusted to the “full fog” position the higher volume of foam or water provides propor-
tionally more cooling for the operator. Also, (as opposed to handlines) monitors can be set up and adjusted - then temporarily
left unattended, if necessary.

Foam/Water Management
Individual/dedicated foam reservoirs at each monitor eliminate the possibility of depleting a central foam storage tank, in
the event a single foam monitor is opened and then left unattended.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K23
www.williamsfire.com

Foam Makers
storage tank fire protection

storage tank fire protection


Product:
High Back Pressure Foam Makers
Medium Flow - Brass

Description:
High Back Pressure Foam Makers are used for “in-line” foam
expansion and delivery into foam fire protection distribution systems that
are subjected to discharge head pressure. They are typically designed
for subsurface foam injection into flammable (combustible) hydrocar-
bon fuels, stored in vertical cone roof atmospheric tanks. In subsurface
applications, expanded foam is injected directly into the fuel, then gently
rises to form a foam blanket at the fuel surface. Maximum allowable
back pressure for the HBFM series High Back Pressure Foam Makers is
40% of foam solution inlet pressure. Flow rates are available from 100
gpm to 300 gpm @ 150 psi inlet pressure. Nominal foam expansion is
4:1. SAE 40, cast brass construction, with stainless steel trim.

For fixed subsurface injection foam system installations, design considerations should address the following (per NFPA
11): application density rate; quantity and configuration of foam injection points; maximum back-pressure allowance; foam
injection velocity.

Model Flow Rate K-Factor Standard Optional Standard Material


@150 psi Inlet Inlet Discharge
HBFM-100B 100 gpm 8.2 2.5” NPT(M) 2.5”NH(F) 2.5”NPT(M) Brass
HBFM-150B 150 gpm 12.2 2.5” NPT(M) 2.5”NH(F) 2.5”NPT(M) Brass
HBFM-200B 200 gpm 16.3 2.5” NPT(M) 2.5”NH(F) 2.5”NPT(M) Brass
HBFM-250B 250 gpm 20.4 2.5” NPT(M) 2.5”NH(F) 2.5”NPT(M) Brass
HBFM-300B 300 gpm 24.5 2.5” NPT(M) 2.5”NH(F) 2.5”NPT(M) Brass

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K24
www.williamsfire.com

Foam Makers
storage tank fire protection

storage tank fire protection


Product:
High Back Pressure Foam Makers
High Flow - Aluminum

Description:
High Back Pressure Foam makers are used for “in-line”
foam expansion and delivery into foam fire protection distribu-
tion systems that are subjected to discharge head pressure. They
are typically designed for subsurface foam injection into flam-
mable (combustible) hydrocarbon fuels stored in vertical cone
roof atmospheric tanks. In subsurface applications, expanded
foam is injected directly into the fuel, then gently rises to form
a foam blanket at the fuel surface. Maximum allowable back
pressure for the HBFM series High Back Pressure Foam Makers
is 40% of inlet pressure. Flow rates are from 300 gpm to 550
gpm @ 150 psi inlet pressure. Nominal foam expansion is 4:
1. T-6 tempered and hardcoat anodized aluminum with stainless
steel trim.

For fixed subsurface injection foam system installations, design considerations should address the following (per NFPA
11): application density rate4; quantity and configuration of foam injection points; maximum back-pressure allowance; foam
injection velocity.

Model Flow Rate K-Factor Standard Optional Discharge Optional Material


@150 PSI Inlet Inlet Discharge
HBFM-300A 300 gpm 23.7 4” Flange 2.5”, 3.5” NH (F) 6” Flange 6”NPT (N) Aluminum
HBFM-350A 350 gpm 27.7 4” Flange 2.5”, 3.5” NH (F) 6” Flange 6”NPT (N) Aluminum
HBFM-400A 400 gpm 31.6 4” Flange 2.5”, 3.5” NH (F) 6” Flange 6”NPT (N) Aluminum
HBFM-450A 450 gpm 35.6 4” Flange 2.5”, 3.5” NH (F) 6” Flange 6”NPT (N) Aluminum
HBFM-500A 500 gpm 39.6 4” Flange 2.5”, 3.5” NH (F) 6” Flange 6”NPT (N) Aluminum
HBFM-550A 550 gpm 43.5 4” Flange 2.5”, 3.5” NH (F) 6” Flange 6”NPT (N) Aluminum

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K25
www.williamsfire.com

Foam Makers
storage tank fire protection

storage tank fire protection


Product:
High Back Pressure Foam Makers
Self Educting

Description:
Proportions foam concentrate at 1% or 3%, then aspirates the
foam solution. Capable of discharging expanded foam against
considerable back pressure, not exceeding 25% of foam solu-
tion inlet pressure. For use in either atmospheric systems or for
subsurface injection. Designed to operate at inlet pressures from
100 to 250 psi. Flow rates are based on 150 psi inlet pressure.
Standard material or construction is SAE 356 cast anodized alu-
minum, heat treated to T6 temper and hard coat anodized to Mil.
A-8625, Type III. Also available (special order) in SAE 40 cast
brass red.

Model Flow Rate K-Factor Standard Standard Optional


@150 psi Inlet Discharge Discharge
SEFM-LB300 300 gpm 24.5 4” 150# Flg. 6” 150# Flg. 6”NPT(M)
SEFM-LB400 400 gpm 32.7 4” 150# Flg. 6” 150# Flg. 6”NPT(M)
SEFM-LB500 500 gpm 40.8 4” 150# Flg. 6” 150# Flg. 6”NPT(M)
SEFM-LB565 565 gpm 46.1 4” 150# Flg. 6” 150# Flg. 6”NPT(M)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
K26
www.williamsfire.com

HOSE
hose

hose
SECTION INDEX

Niedner Municipal Hose..................................................................................................................................................................L2

Niedner Supplyline Hose................................................................................................................................................................L3

DOUBLE-5 BRAND™ HOSE..................................................................................................................................................................L4

Friction Loss Chart.............................................................................................................................................................................L5

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
L1
www.williamsfire.com

NIEDNER
Light on Weight — Heavy on Technology
hose

hose
Municipal Hose

XL-800
General specifications covering lightweight T.P.U. lined, Municipal fire
hose manufactured by NIEDNER in sizes 1.5” (38 mm), 1.75” (45mm), 2”
(50 mm), 2.5” (65 mm) and 3” (76 mm).

XL-800
Test pressure: 800 PSIG (5600kPa)
Specification: The hose shall be of double jacket construction with 100%
spun polyester yarn in both jackets. There shall also be a minimum of 10
filler yarns per inch in both jackets.
The thickness of the lining shall be .020” minimum and it shall be con-
structed of T.P.U. elastomer.
The outside jacket shall be treated with ENCAP™ elastomer which
shall completely encapsulate the jacket fibers and not merely surface coat
the jacket.
The hose shall remain flexible to -60˚ F (-51˚ C).

For more information please call Williams Fire & Hazard Control, Inc®

SPECIFICATIONS
Size: Weight/50’ uncpld Coil diameter:
1.5” (38mm) 11.5 lbs. 15.0” (38 cm)
1.75” (45mm) 13.0 lbs. 15.0” (38 cm)
2” (50mm) 15.5 lbs. 15.5” (39 cm)
2.5” (65mm) 20.0 lbs. 16.0” (41 cm)
3” (76mm) 26.0 lbs. 16.0” (41 cm)

HYDROSTATIC SPECIFICATIONS
Service Test Pressure 400 PSIG
Proof Pressure: 800 PSIG
Elongation: 10%
Warp: 20”
Rise: 0”
Kink burst: 600 PSIG (450-3”)
Burst: 1200 PSIG
PHYSICAL PROPERTIES
Spec Number Size Wt/50 ft. Coil Dia. Coupling
Uncpld per 50 ft. Bowl Size
4015 1.5” 11.5 lbs. 15.0” 1.9375”
4017 1.75” 13.0 lbs. 15.0” 2.0625”
4020 2” 15.5 lbs. 15.5” 2.3125”
4025 2.5” 20.0 lbs. 16.0” 3”
4030 3” 26.0 lbs. 16.0” 3.5625”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
L2
www.williamsfire.com

NIEDNER
When the going gets tough, SUPPLYLINE.....gets going.
hose

hose
SupplyLine
General specifications covering lightweight T.P.U. lined, large diameter
fire hose manufactured by Niedner in sizes 4”, 5” and 6”.

SupplyLine
Provided with Storz and optional ENCAP™ treatment. Yellow color.
Specification: The hose shall be of double jacket construction with 100%
polyester yarn in both jackets. There shall be a minimum of 13 filler yarns
per inch in the inner jacket and a minimum of 10.5 filler yarns per/inch in
the outer jacket of the 4”. There shall be a minimum of 14 filler yarns per
inch in the inner jacket and a minimum of 10 filler yarns per inch in the
outer jacket of the 5” (125 mm). The thickness of the lining shall be .020”
(.504 mm) for the 4” (100 mm) and .020” (.504 mm) for the 5” (125 mm).
It shall be extruded from clear T.P.U. elastomer. The maximum weight of
a 50 foot (15m) length of hose, uncoupled, shall be 34 lbs. (15.4 kg) for 4”
and 42 lbs. (19.0 kg) for 5”. The hose shall remain flexible to -60˚ F (-51˚
C). Options: The outside jacket shall be treated with ENCAP™ elastomer
which shall completely encapsulate the jacket fibers and not merely surface
coat the jacket.

SupplyLine
Higher burst pressure Less elongation when pressurized
Higher test pressure Less weight
Higher kink burst Less drag resistance
Greater abrasion resistance Less bulk
Flexibility to -60˚ F (-51˚ C) Less storage space required
Easier to load and unload Low maintenance

For more information please call Williams Fire & Hazard Control, Inc®

SIZE 4” 5” 6”
Proof Pressure: 600 PSIG 600 PSIG 600 PSIG
Service test pressure: 300 PSIG 300 PSIG 300 PSIG
Coil Diameter (100’ lengths) 24” (61 cm) 25” (64 cm) 26” (67 cm)
Weight cpd (100’ lengths) 82 lbs 102 lbs 150 lbs

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
L3
www.williamsfire.com

DOUBLE-5 BRAND
hose

hose
Product:
DOUBLE-5 BRAND™ Hose

Description:
Double Jacket all polyester hose intended to transfer large
volumes of water with minimal friction loss of less than 3 psi per
100 feet. Lightweight and compact, occupies less space than con-
ventional single jacket hose. Flexible to -60˚F (-51˚ C).

Construction:
Circular woven double jacket 100% virgin polyester.

Tube:
Extruded elastomer - Ozone and age resistant.

Length:
Up to 250’

Standard Features:
ENCAP™ encapsulation

Custom 7.25-6” Storz Couplings

Hose Spec Weight Proof Service Burst


Size Number 100’ Pressure Test Pressure
Pressure
7.250” 7000 160 lbs 600 PSIG 300 PSIG 750 PSIG
184 mm 48.5 kg 4200 kPa 2100 kPa 5171 kPa

For US and Foreign Patent and Trademark information, please refer to page IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
L4
www.williamsfire.com

Friction Loss in Rubber or Vinyl Lined Fire Hose


hose

hose
Flow in U.S. Pressure Loss in PSI per 100’ Hose
Gallons Hose Diameters
Per Minute
1.5” 1.75” 2.0” 2.5” 3” 3.5” 4” 5” 6” 7.25”
10
20
30
40 4.5 3 1
60 10 5 2.5
95 22 11 5
100 25 12 6 3 1
125 37 21 10 4 1
150 54 26 13.5 6 2
175 34 18 8 3
200 45 24 10 4 2
225 57 30 12 4.5 2
250 70 37.5 15 6 2.5
275 82 45 17.5 7 3
300 95 54 21 8 3.5 2
325 65 24.5 9.5 4 2.5
350 78 28 11 5 2.5
400 96 36 14 6 3 1
450 45 17.5 8 4 1.5
500 55 21 9.5 5 2
550 25.5 11.5 6 2
600 30 13.5 7 2.5
650 35 15.5 8.5 3
700 40.5 18 9.5 3.5 1
750 46 20 11.5 4 1
800 53 23 12.5 4.5 1.5
850 25.5 14.5 5 1.5
900 28 16 5.5 2
950 31 17.5 6 2
1000 34 19 6.5 2.5
1100 41 23 8 3 1
1200 49 27.5 9.5 4 1.2
1300 57 32.5 11 4.5 1.4
1400 66.5 38 13 5 1.5
1500 76.5 43 15 6 2
1750 59 20 8 2.5
2000 77 26.5 10.5 3
2500 41.5 16.5 4.8

NOTE: These friction loss figures will vary accordingly with age and manufacturer of hose
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
L5
www.williamsfire.com

HOSE ACCESSORIES
hose accessories

hose accessories
SECTION INDEX

PAGES M2 THRU M6

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
M1
www.williamsfire.com

Swivel Joint 3-Way Ball Valve


For use on valve inlets, the new Swivel Joint (HSJ) will Feed multiple small lines with one large line. Relief
hose accessories

hose accessories
swivel UNDER PRESSURE! The primary application is on valve standard. 12” L x 14” W x 10” H, Wt. 22 lb.
appliances that are placed on the ground, such as a manifold or
ball valve. If the connecting large diameter hosed is twisted,
there may be a tendency to flip the appliance over when water
reaches it. The Swivel Joint will reduce or eliminate this pos-
sibility.
The HSJ can also be used on any valve or pump con-
nection where the Swivel Under Pressure capability might be
advantageous. It will swivel at any pressure up to the burst
pressure of the hose.
Inlet Storz Small Outlets Part No.
4” (3) 2.5” male H300-40-25NH
4” (3) 3” storz H300-40-30ST
5” (3) 2.5” male H300-50-25NH
5” (3) 3” storz H300-50-30ST

2-Way Ball Valve


L. 10”, W.9”, Ht. 8”, Wt. 11.5 lb.

Manifold
This light-weight, compact unit is a simple, economical
way to feed multiple small lines with one large line, and con-
tinue with a large line. All outlets are valved. Relief valve Inlet Storz Small Outlets Part No.
and pressure gauge are standard. 16” L x 22” W x 11” H, Wt.
51.5 lb. 4” (2) 2.5” male H200-40-25NH
4” (2) 3” storz H200-40-30ST
5” (2) 2.5” male H200-50-25NH
5” (2) 3” storz H200-50-30ST

SuperFlow 2-Way Ball Valve


Feed multiple large diameter lines with a large diam-
eter line. Optional controlled motion feature (shown)
reduces the possibility of water hammer due to rapid
shut-down. 16” L x 18” W x 11” H, Wt. 52.5 lb.

Inlet Outlet Small Outlets Part No.


Storz Storz
Inlet Storz Small Outlets Part No.
4” 4” (4) 2.5” male H400-40-40-25NH
4” (2) 4” storz H600-40-40
5” 4” (4) 2.5” male H400-40-40-25NH
5” (2) 4” storz H600-50-40
5” 5” (4) 2.5” male H400-40-40-25NH
5” (2) 4” storz H600-50-50

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
M2
www.williamsfire.com

Large Diameter Hose Accessories


hose accessories

hose accessories
LDH Hydrant Valve Siamese 2-Way, 3-Way, 4-Way & Jumbo
Designed and manufactured by AWG, this unique The reliable clappered siamese for feeding one large line
valve permits the first-in pumper to lay the large diameter with multiple lines.
line directly from hydrant to fire and start pumping water.
Later, if more pressure is required to boost the pressure
at the hydrant to take full advantage of available water,
another pumper can connect to the hydrant valve and start
pumping with no interruption in flow. A third position
provides emergency shut-down capability. 12.5” L x 17”
W x 13” H, Wt. 37 lb.

Storz Hydrant Part No


4” 4” NH H700-40-40NH
4” 4.5” NH H700-40-45NH
Outlet Storz Hydrant Part No
5” 4” NH H700-50-40NH
4” (2) 2.5” NH Swivel H220-40-25NH
5” 4.5” NH H700-50-45NH
4” (2) 3” Storz H220-40-30ST
5” (2) 2.5” NH Swivel H220-50-25NH
5” (2) 3” Storz H220-50-30ST
Gate Valve Siamese 2-Way 9.5” L x 10” W x 5” H, Wt. 9 lb
Another AWG design, this is a high quality basic gate
valve for hydrant or pumper use. Lightweight and com-
pact, it incorporates an air bleed-off into the non-rising Outlet Storz Hydrant Part No
stem design. 8.5” L x 8” W x 15” H, Wt. 22 lb 4” (3) 2.5” NH Swivel H330-40-25NH
4” (3) 3” Storz H330-40-30ST
5” (3) 2.5” NH Swivel H330-50-25NH
5” (3) 3” Storz H330-50-30ST
Siamese 3-Way 14” L x 15” W x 9” H, Wt. 18 lb

Outlet Storz Hydrant Part No


Storz Hydrant Part No 4” (4) 2.5” NH Swivel H440-40-25NH
4” 4” NH H800-40-40NH 4” (4) 3” Storz H440-40-30ST
4” 4.5” NH H800-40-45NH 5” (4) 2.5” NH Swivel H440-50-25NH
4” 5” NH H800-40-50NH 5” (4) 3” Storz H440-50-30ST
4” 6” NH H800-40-60NH Siamese 4-Way 17” L x 22” W x 9” H, Wt. 23 lb
4” 4” Storz H800-40-40ST
5” 4” NH H800-50-40NH Outlet Storz Hydrant Part No
5” 4.5” NH H800-50-45NH 4” (2) 4” Storz HJ20-40-25ST
5” 5” NH H800-50-50NH 4” (2) 4” Storz HJ20-50-40ST
5” 6” NH H800-50-60NH 5” (2) 5” Storz HJ20-50-50ST
5” 5” Storz H800-50-50ST Siamese Jumbo 16.5” L x 13.75” W x 8” H, Wt. 29.5 lb
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
M3
www.williamsfire.com

Large Diameter Hose Accessories


hose accessories

hose accessories
30º Elbow With Relief Valve, 30º Elbow With Long Handle Swivels
Air Bleed-Off

Storz Hydrant Part No


4” 4” NH H30ERV-40-40NH
Storz Part No
4” 4.5” NH H30ERV-40-45NH
4’ x 4” NH Long Handle H30E-40-40NHLH
4” 5” NH H30ERV-40-50NH
4’ x 4.5” NH Long Handle H30E-40-45NHLH
4” 6” NH H30ERV-40-60NH
4’ x 5” NH Long Handle H30E-40-50NHLH
4” 4” Storz H30ERV-40-40ST
4’ x 6” NH Long Handle H30E-40-60NHLH
5” 4” NH H30ERV-50-40NH
5’ x 4” NH Long Handle H30E-50-40NHLH
5” 4.5” NH H30ERV-50-45NH
5’ x 4.5” NH Long Handle H30E-50-45NHLH
5” 5” NH H30ERV-50-50NH
5’ x 5” NH Long Handle H30E-50-50NHLH
5” 6” NH H30ERV-50-60NH
5’ x 6” NH Long Handle H30E-50-60NHLH
5” 5” Storz H30ERV-50-50ST

30º Elbow With Rocker Lug Swivels Storz To Female Thread - Rigid

Storz Hydrant Part No Storz Part No


4” 2.5” NH Swivel H30E-40-25HRL 2” 1.5” NH HSFR20-15NH
4” 3.5” NH Swivel H30E-40-30HRL 3” 2.5” NH HSFR30-25NH
4” 2.5” NH Swivel H30E-40-35HRL 4” 2.5” NH HSFR40-25NH
4” 3.5” NH Swivel H30E-40-40HRL 4” 3 “ NH HSFR40-30NH
4” 2.5” NH Swivel H30E-40-45HRL 4” 3.5” NH HSFR40-35NH
4” 3.5” NH Swivel H30E-40-50HRL 4” 4” NH HSFR40-40NH
4” 2.5” NH Swivel H30E-40-60HRL 4” 4.5” NH HSFR40-45NH
4” 5” Storz H30E-40-40ST 4” 5” NH HSFR40-50NH
5” 2.5” NH Swivel H30E-50-25HRL 4” 6” NH HSFR40-60NH
5” 3” NH Swivel H30E-50-30HRL 5” 2.5” NH HSFR50-25NH
5” 3.5” NH Swivel H30E-50-35HRL 5” 3” NH HSFR50-30NH
5” 4” NH Swivel H30E-50-40HRL 5” 3.5” NH HSFR50-35NH
5” 4.5” NH Swivel H30E-50-45HRL 5” 4” NH HSFR50-40NH
5” 5” NH Swivel H30E-50-50HRL 5” 4.5” NH HSFR50-45NH
5” 6” NH Swivel H30E-50-60HRL 5” 5” NH HSFR50-50NH
5” 5” Storz H30E-50-50ST 5” 6” NH HSFR50-60NH

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
M4
www.williamsfire.com

Large Diameter Hose Accessories


hose accessories

hose accessories
Storz To Female Thread- Storz to Male Thread-
Swivel Rocker Lug

Storz Part No Storz Part No


3” 2.5” NH HSFS30-25NHRL 2” 1.5”NH HSMR20-15NH
4” 2.5” NH HSFS40-25NHRL 3” 2.5”NH HSMR30-25NH
4” 3” NH HSFS40-30NHRL 4” 2.5”NH HSMR40-25NH
4” 3.5 “ NH HSFS40-35NHRL 4” 3”NH HSMR40-30NH
4” 4” NH HSFS40-40NHRL 4” 3.5”NH HSMR40-35NH
4” 4.5” NH HSFS40-45NHRL 4” 4”NH HSMR40-40NH
4” 5” NH HSFS40-50NHRL 4” 4.5”NH HSMR40-45NH
4” 6” NH HSFS40-60NHRL 4” 5”NH HSMR40-50NH
5” 2.5” NH HSFS50-25NHRL 4” 6”NH HSMR40-60NH
5” 3” NH HSFS50-30NHRL 5” 2.5”NH HSMR50-25NH
5” 3.5” NH HSFS50-35NHRL 5” 3”NH HSMR50-30NH
5” 4” NH HSFS50-40NHRL 5” 3.5”NH HSMR50-35NH
5” 4.5” NH HSFS50-45NHRL 5” 4”NH HSMR50-40NH
5” 5” NH HSFS50-50NHRL 5” 4.5”NH HSMR50-45NH
5” 6” NH HSFS50-60NHRL 5” 5”NH HSMR50-50NH
5” 6”NH HSMR50-60NH

Straight Female Swivel-


Long Handle
Storz Blind Caps

Storz Part No
4’ x 4” NH Long Handle HSFS40-40NHLH
4’ x 4.5” NH Long Handle HSFS40-45NHLH Storz Part No
4’ x 5” NH Long Handle HSFS40-50NHLH 2” HBC-20
4’ x 6” NH Long Handle HSFS40-60NHLH 3” HBC-30
5’ x 4” NH Long Handle HSFS50-40NHLH 4” HBC-40
5’ x 4.4” NH Long Handle HSFS50-45NHLH 5” HBC-50
5’ x 5” NH Long Handle HSFS50-50NHLH 6” HBC-60
5’ x 6” NH Long Handle HSFS50-60NHLH

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
M5
www.williamsfire.com

KOCHEK
hose accessories

hose accessories
Product:
Ball Intake Valve

Hi quality valve with low friction loss

Description:
The AWG ball intake valve is designed for the highest waterflow capability with the lowest friction loss possible. Years
of experience manufacturing ball intake valves and state of the art design lead to a new type of ball intake valve which is
superior to all similar products.

• Line item 55K


• Less than 2.5 lbs friction loss @ 2,200 gpm
• Meets 900 psi hydrostatic strength test
• Drafting through Valve Capable
• Meets NFPA requirements
• 30˚ Intake Elbow
• Handwheel can be removed
• Indicator of ball position
• Adjustable relief valve from 50 to 250 psi
• StainlessSteel 3/4” drain valve
• Corrosion resistant, Dry Body design
• Optional Full Time Swivel
• FUll flow ball — 3,000 gpm

Female Swivel Thread


STORZ
4.5” NH 5” NH 6” NH
4” 55K45104 55K50104 55K60104
5” 55K45105 55K50105 55K60105
4” FTS* 55K45104T 55K50104T 55K60104T
5” FTS* 55K45105T 55K50105T 55K60105T
6” FTS* 55K45106T 55K50106T 55K60106T

* FTS (Full Time Swivel) - optional lock available

For more information please call Williams Fire & Hazard Control, Inc®

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
M6
www.williamsfire.com

COMPONENTS FOR FIRE APPARATUS


components for fire apparatus

components for fire apparatus


SECTION INDEX

Williams’ Advent 10 Foam System.....................................................................................................................................N2-N3

Williams’ “High Head” Through-the-Pump 1500 Portable Foam System............................................................ N4

Williams’ Pressure Reducing Valve (WPRV/3, 3P, 4 & 4P)............................................................................................N5

Williams’ “HIGH HEAD” ATP 500 A/B Foam System............................................................................................................N6

Ratio Controller Detail.....................................................................................................................................................................N7

Spectrum Ratio Controllers, 2” & 2.5” -Threaded Type.................................................................................................N8

Spectrum Ratio Controllers, 5” Grooved...............................................................................................................................N9

Spectrum Ratio Controllers, 3”,4”,6”,8”- Wafer Style...................................................................................................N10

Williams’ “High-Head” Around the Pump WATP-1500B Truck Foam System............................................N11-N12

Williams’ “High-Head” Around the Pump WATP-1500V Truck Foam System......................................N13-N14

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N1
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Product:
Williams’ Advent 10 Foam System

When simplicity counts, count on the Williams’


Advent 10 Foam System!
The Advent 10 system was designed with the Firefighter
in mind. An emergency is not the time to perform complicated
procedures in order to operate the foam system.
The Advent 10 system requires the operator to turn ONE
SWITCH. It’s that easy! The Williams’ Advent 10 Foam
System offers the proven performance and reliability of bal-
anced pressure technology in a user-friendly package.
This system was developed to handle the modern Class
“B” (Thixotropic) AR type concentrates and Class “A” AFFF’s being used today. A small amount of concentrate is always
being circulated through the foam manifold and returned to the suction side of the foam pump. This keeps the concentrates
from becoming gelatinous, and ensures that foam is immediately available should a discharge be opened.
The system can be driven electrically, using the on-board generator (Advent 10 Only), or from the chassis transmission
via a Power Take Off (PTO). Driving the system independently also allows the concentrate pump to operate separately from
the water pump. The electric powered unit permits the system to function over a broader operating range.

Advantages:
•Cost effective when compared to systems with equivalent capabilities.
•Multiple foam injection points.
•Simultaneous variable proportioning rates.
•Broad range of flows.
•Capable of handling “A” or “B” foams.
•All mechanical construction, no electronics.
•No additional load on the chassis electrical system.
•Automatic pressure control.
•Manual by-pass capability.
•Installer friendly. Does not require common manifolding.
•Solution Flow Rate up to 333 GPM@ 3% or 1000 GPM @ 1%. (Advent 10)
•Advent systems are available for concentrate flow rates from 10 GPM to 120 GPM and solution flow rates from 40 GPM
to 5,000 GPM.

SOLD SEPARATELY

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N2
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Product:
Williams’ Advent 10 Foam System

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N3
www.williamsfire.com

Foam Proportioning & Loose Equipment


components for fire apparatus

components for fire apparatus


Product:
Williams’ “High Head” Through-the-Pump
1500 Portable Foam System

Description:
The Williams High Head Through-the-Pump 1500 Portable Foam
System was designed to turn any pumper into a foam producing device. This
unit will proportion 3% foam solution up to 1500 GPM. It can work against
hydrant pressure up to 50 PSI with only 150 PSI discharge pressure. This
economical system is easy to use and is completely water driven; there are no
pumps or parts to maintain. Can’t get the foam to the pump? Not a problem!
The WTTP was designed to proportion foam from remote locations.

Features:
• Operates against 33% Pump Suction Pressure.
(Example: Master Pressure @150 PSI, Suction Pressure @ 50 PSI)
• Proportions Class “B” Foam up to 1500 GPM at 3%.
• Proportions Class “B” Foam up to 750 GPM at 6%.
• Positive Shut-Off on Metering Valve.
• Requires no maintenance.
• Portable.
• Water Powered.
• Remote Proportioning Capabilities.
• Check Valve Prevents Water from “Back Flowing” into
Concentrate Source.

System Includes:
• Base Unit with Jet Pump & Metering Valve.
• 2.0” Clear Concentrate Pick-Up Hose.
• 2.0” Valved Drum Stinger.

Materials of Construction:
• Brass with Stainless Steel Trim.
Notes:
1. At 50 psi water pump inlet, maximum hose lay is 25 ft. of 3.0” hose.
2. For drafting operations or pressures below 10 psi, use the 10 psi numbers shown above.

Maximum Hose Lay (ft) For Remote Proportioning Portable WATP 1500 System
PUMP INLET PRESSURE
Solution 10 PSI 20 PSI 30 PSI 40 PSI
Rate HOSE SIZE HOSE SIZE HOSE SIZE HOSE SIZE
3% 6% 2.5” 3” 2.5” 3” 2.5” 3” 2.5” 3”
120 60 950 1700 700 1300 500 850 250 400
250 125 850 1600 650 1200 450 800 225 375
500 250 750 1400 600 1050 400 700 200 350
750 375 650 1250 500 950 350 600 175 300
1000 500 600 1100 450 800 300 550 150 250
1500 750 500 900 350 700 250 450 100 200

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N4
www.williamsfire.com

Foam Proportioning & Loose Equipment


components for fire apparatus

components for fire apparatus


Product:
Williams’ Pressure Reducing Valve
(WPRV/3, 3P, 4 & 4P)

Description:
Maintains constant pre-set inlet pressure for use in conjunc-
tion with the Williams “High Head” Through/Around The Pump
(or comparable) foam systems. Allows any firewater pump to pro-
duce suction side foam at virtually ANY positive inlet pressure.
As such, the WPRV eliminates need for operator intervention to
adjust intake gate valves due to suction pressure fluctuations as a
result of changes in pump discharge flow. Thus, the added burden
of assuring a maximum pump intake pressure (based on pump
discharge pressure) associated with traditional suction side foam
systems simply goes away.

Additional Applications:
Got a CAFS or Balanced Pressure system? The WPRV can provide reduced pump inlet pressures to allow increased
engine/PTO speed to maintain higher compressor or foam pump output when operating with positive pump inlet pressures.
Installed within a discharge line, the WPRV maintains a preset pressure for hand lines or ground monitors independent of
higher pump discharge pressures.

Features:
3 Modes of Operation:
1. AUTOMATIC – Controls pre-set pressure from 15-115 PSI
2. OPEN – Full flow to rated capacity
WPRV/3 – 500 GPM w/ 7 PSI drop
WPRV/4 - 1500 GPM w/ 20 PSI drop
3. CLOSED – Bubble tight shut off
• NFPA 1901, 14-6 COMPLIANT – Exclusive WPRV pilot control also provides bubble tight shut off to comply with
NFPA 1901, 19-3.6, TIA 99-1 preventing foam solution back flow into a potable (hydrant system) water supply
• PRESSURE RATINGS – 230 PSI Max. — 20 PSI Min. (Prevents reducing hydrant system pressures below 20 PSI)
• INLET/OUTLET – WPRV/3: 2.5” NST; WPRV/4: 5” Storz

Options:
WPRV/3 & 3P (Portable)
• “In-Truck” installation with panel mount control valve, standard 2.5” (F)NST swivel inlet w/ strainer and bleeder port
• 3” NST inlet w/strainer/outlet
• 4” Storz inlet w/strainer/outlet WPRV/4 & 4P (Portable)
• “In-Truck” installation with panel mount control valve, standard 5” Storz inlet w/strainer, adjustable intake relief,
bleeder port and mounting hardware
• Inlet intake relief valve & bleeder (4P)
• 4” Storz inlet w/strainer/outlet
• 6” (F)NST swivel outlet for direct mounting to pump intakes
• Inlet/outlet pressure gauges
• Carrying handle
• 5” LDH X 10’ Long with 5” Storz couplings (200 PSI operating pressure)

Materials of Construction:
• WPRV/3 & 3P – Epoxy coated cast iron w/brass and stainless steel trim
• WPRV/4 & 4P – Epoxy coated & anodized aluminum w/ brass and stainless steel trim

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N5
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Product:
Williams’’ “High Head” ATP 500 A/B Foam System

Description:
Now you can have the proven reliability of a Williams Around The Pump
Foam System, combined with the flexibility of a Class “A” and Class ”B”
Proportioner in one convenient, easy to use package. No need to fumble with
confusing change over valves, because one valve allows you to select the foam
source and set the foam concentrate percentage. This system features the ability to
infinitely adjust, or “tweak” the foam concentration for Class “A” (1%) or Class
“B” (3%) solutions to a maximum of 500 GPM.

Features:
• Operates against 33% Pump Inlet Pressure.
(Example: 150 PSI Discharge Pressure w/50 PSI on Water Pump Inlet)
• Proportions Class “A” Foam up to 500 GPM at 1%.
• Proportions Class “A” Foam up to 1000 GPM at .5%.
• Proportions Class “B” Foam up to 500 GPM at 3%.
• Positive Shutoff on Metering Valve.
• Balanced Ball Design is easy to operate.
• Requires no maintenance.
• Ergonomic grip handle is easy to use.
• Flush port is built into Metering Valve.
• Simplicity of operation.

Materials of Construction:
• Body SAE 40 “Red” Brass
• Ball SAE 360 Brass
• Seats 15% Glass-filled Teflon
• Shaft 316 Stainless Steel

METERING SELECTION CHART FOR WATP-500 “A”


(FLOWS IN GPM)
FOAM METERING VALVE POSITION
% I II III IV V VI
.25 240 380 500 1000 1500 2000
.5 120 190 250 500 750 1000
.75 80 127 167 333 500 667
1.0 60 95 125 250 375 500
METERING SELECTION CHART FOR WATP-500 “B”
(FLOWS IN GPM)
FOAM METERING VALVE POSITION
% I II III IV V VI
1 180 285 375 750 1125 1500
2 90 142.5 187.5 375 562.5 750
3 60 95 125 250 375 500
4 45 71.25 93.75 187.5 281.25 375
5 36 57 75 150 225 300
6 30 47.5 62.5 125 187.5 250

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N6
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Ratio Controller Detail

Threaded - 2” and 2.5”

Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet


Controller Size ATC Flow AFFF Flow AFFF Flow
2” Threaded 80-200 gpm 40-200 gpm 1% / 3% / 6% 1” NPT (M)
2.5” Threaded 160-500 gpm 80-500 gpm 1% / 3% / 6% 1” NPT (M)

Grooved - 5”

Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet


Controller Size ATC Flow AFFF Flow AFFF Flow
5” Victaulic™ or 400-1800 gpm 200-1800 gpm 1% / 3% / 6% 2” NPT (F)
Gruv-Lok™

Wafer Style - 3”, 4”, 6”, 8”

Ratio Controller Configuration Nominal Nominal Proportioning D


Size ATC Flow AFFF Flow
3” Wafer, Between Flange 200-700 gpm 100-700 gpm 1% / 3% / 6% 1.25”
4” Wafer, Between Flange 300-1250 gpm 175-1250 gpm 1% / 3% / 6% 1.5”
6” Wafer, Between Flange 500-2500 gpm 350-2500 gpm 1% / 3% / 6% 2”
8” Wafer, Between Flange 950-4500 gpm 700-4500 gpm 1% / 3% / 6% 2.5”
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N7
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Product:
Spectrum Ratio Controllers, 2” & 2.5” -Threaded Type

Description:
Ratio Controllers are modified venturi foam proportioners that accurately meter pressurized foam concentrate into the
firewater stream. These foam proportioners are used in conjunction with balanced pressure systems, such as bladder tanks and
pumped proportioning skids. In operation, firewater flows through the modified venturi, creating an area of lower pressure,
which is referred to as the “metering pressure drop”. This metering pressure drop is directly effected by the firewater velocity
as it flows through the venturi. The (1%, 3% or 6%) concentrate-to-water ratio is maintained over the entire flow range of each
size ratio controller. However, each size ratio controller has a minimum flow rate/velocity requirement, and these minimums
must be maintained for proper ratio controller operation.

Each Spectrum Ratio Controller consists of the following components: body; metering orifice; inlet nozzle. These com-
ponents are constructed of ASTM 85-5-5-5 bronze. The inlet nozzle is tapered and machined to a smooth finish to maximize
water stream efficiency through the venturi. The foam concentrate metering orifice is sized to the exact type and percentage
of foam concentrate to be used. Both the inlet nozzle and metering orifice are secured by a stainless steel retaining ring.

2” 2.5”
A 2.375” 2.875”
B 7” 7”
C 2.0625” 2.0625”
D 3.75” 4.125”
E* 10” 13”

*Minimum straight pipe lengths


required upstream/downstream
of controller.

Ratio Configuration Nominal Nominal Proportioning Concentrate


Controller Size ATC Flow AFFF Flow (Fixed) Inlet
2” Threaded 80-200 gpm 40-200 gpm 1%/3%/6% 1”NPT (M)
2.5” Threaded 160-500 gpm 80-500 gpm 1%/3%/6% 1”NPT (M)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N8
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Product:
Spectrum Ratio Controllers, 5” Grooved

Description:
The Spectrum 5” Grooved Ratio Controller is a modified
venturi foam proportioner that accurately meters pressurized
foam concentrate into the firewater stream. This foam propor-
tioner is used in conjunction with balanced pressure systems,
such as bladder tanks and pumped proportioning skids. In
operation, water flows through the modified venturi, creating
an area of lower pressure, which is referred to as the “metering
pressure drop”. This metering pressure drop is directly effected
by the firewater velocity as it flows through the venturi. The
(1%, 3% or 6%) concentrate-to-water ratio is maintained over
the entire flow range of the ratio controller. However, each
size ratio controller has a minimum flow rate/velocity require-
ment, and these minimums must be maintained for proper ratio
controller operation.

The Spectrum Ratio Controller consists of the following


components: body; metering orifice; inlet nozzle. These com-
ponents are constructed of ASTM 85-5-5-5 bronze. The inlet nozzle is tapered and machined to a smooth finish to maximize
water stream efficiency through the venturi. The foam concentrate metering orifice is sized to the exact type and percentage
of foam concentrate to be used. Both the inlet nozzle and metering orifice are secured by a stainless steel retaining ring.

Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet


Controller Size ATC Flow AFFF Flow (Fixed)
5” Victaulic™ or 400-1800 gpm 200-1800 gpm 1%/3%/6% 2”NPT (F)
Gruv-Lok™

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N9
www.williamsfire.com

Fire Apparatus Components


components for fire apparatus

components for fire apparatus


Product:
Spectrum Ratio Controllers, 3”,4”,6”,8”- Wafer Style

Description:
Spectrum Ratio Controllers are modified venturi foam proportion-
ers that accurately meter pressurized foam concentrate into the firewater
stream. These foam proportioners are used in conjunction with balanced
pressure systems, such as bladder tanks and pumped proportioning skids.
In operation, firewater flows through the modified venturi, creating an area
of lower pressure, which is referred to as the “metering pressure drop”.
This metering pressure drop is directly effected by the firewater velocity
as it flows through the venturi. The (1%, 3% or 6%) concentrate-to-water
ratio is maintained over the entire flow range of each size ratio control-
ler. However, each size ratio controller has a minimum flow rate/velocity
requirement, and these minimums must be maintained for proper ratio con-
troller operation.

Designed to be installed between two 150# F.F. flanges, each Spectrum Ratio Controller consists of the following com-
ponents: body; metering orifice; inlet nozzle. These components are constructed of ASTM 85-5-5-5 bronze. The inlet nozzle
is tapered and machined to a smooth finish to maximize water stream efficiency through the venturi. The foam concentrate
metering orifice is sized to the exact type and percentage of foam concentrate to be used. Both the inlet nozzle and metering
orifice are secured by a stainless steel retaining ring. F.M. approved, File No. J.I.1R6A3.AF.

3” 4” 6” 8”
A 2.375” 2.5” 3.25” 3.5”
B 6.0625” 8” 12” 12”
C 2.625” 3.125” 4.125” 5.25”
D 1.25” 1.5” 2” 2.5”
E* 15” 20” 30” 40”
Weight 10 lbs. 16 lbs. 32 lbs. 3 lbs.

*Minimum straight pipe length required upstream/


downstream of controller.

Ratio Configuration Nominal Nominal Proportioning


Controller Size ATC Flow AFFF Flow (Fixed)
3” Wafer, Between Flange 200-700 gpm 100-700 gpm 1%/3%/6%
4” Wafer, Between Flange 300-1250 gpm 175-1250 gpm 1%/3%/6%
6” Wafer, Between Flange 500-2500 gpm 350-2500 gpm 1%/3%/6%
8” Wafer, Between Flange 950-4500 gpm 700-4500 gpm 1%/3%/6%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N10
www.williamsfire.com

Foam Systems
components for fire apparatus

components for fire apparatus


Product:
Williams’ “High-Head” Around the Pump
WATP-1500B Truck Foam System

Description:
The Williams ‘High Head’ Around-the Pump 1500
Foam System is designed to be installed within the appara-
tus piping to provide foam proportion at 1%/3%/6% foam
solutions up to 4500/1500/750 GPM respectively.
The system will operate against hydrant pressures up
to 33% of pump main discharge pressure. This economical
system is easy to use and completely water driven - there
is no pump to maintain. The WATP can proportion foam
from an on-board foam cell or remote source via an exter-
nal auxiliary foam inlet (apparatus manufacture supplied).
Optional clear PVC foam concentrate pickup hose(s) and single/double ‘stinger’ tubes are available for use with external
foam concentrate sources.
Designed as a single agent system for use with Class ‘B’ foam concentrates, the WATP-1500 system can be used with
Class ’A’ foam concentrates as well and can be configured as a dual agent system as an option. Optional metering valve set-
tings can be provided as needed as well at an additional cost.

Features:
• Operates against 33% Pump Suction Pressure.
(Example: Master Pressure @150 PSI, Suction Pressure @ 50 PSI)
• Proportions Class “B” Foam up to 4500 GPM at 1%.
• Proportions Class “B” Foam up to 1500 GPM at 3%.
• Proportions Class “B” Foam up to 750 GPM at 6%.
• Positive Shut-Off on Metering Valve.
• Requires no maintenance.
• Water Powered.
• External Foam Source Capabilities.
• NFPA 1901 Compliant When Equipped With Williams 4” WPRV/4T Intake Pressure Reducing Valve.

Basic System Includes:


• Jet Pump, Metering Valve, Check Valve, In-Line Strainer, Motive Water Control Valve, Control Panel and Block
Valves.

Materials of Construction:
•Brass, Stainless Steel and Stainless Steel Trim.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N11
www.williamsfire.com
components for fire apparatus

components for fire apparatus

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N12
www.williamsfire.com

Foam Systems
components for fire apparatus

components for fire apparatus


Product:
Williams’ “High-Head” Around the Pump
WATP-1500V Truck Foam System

The Williams ‘High Head’ Around-the Pump 1500V


Foam System is designed to be installed within the appa-
ratus piping to provide foam proportion at. 25% / .5% / 1%
/ 3% / 6% foam solutions up to 4800 / 4500 / 4000 / 1500
/ 750 GPM respectively. The system will operate against
hydrant pressures up to 33% of pump main discharge pres-
sure. This economical system is easy to use and completely
water driven - there is no foam pump to maintain. The
WATP can proportion foam from on-board foam cell(s) or
remote source via an external auxiliary foam inlet (apparatus manufacture supplied).
Optional clear PVC foam concentrate pick-up hose(s) and single/double ‘stinger’ tubes are available for use with external
foam concentrate sources.
Designed as a dual agent system for use with Class ‘A’ and Class ‘B’ foam concentrates, the system features a variable
metering valve that allows infinite adjustment to accommodate accurate foam solution flows between any two specific meter-
ing valve positions.

Features:
• Operates against 33% Pump Suction Pressure.
(Example: Master Pressure @150 PSI, Suction Pressure @ 50 PSI)
• Proportions Class “B” Foam up to 4000 GPM at 1%.
• Proportions Class “B” Foam up to 1500 GPM at 3%.
• Proportions Class “B” Foam up to 750 GPM at 6%.
• Positive Shut-Off on Metering Valve.
• Requires no maintenance.
• Water Powered.
• External Foam Source Capabilities.
• NFPA 1901 Compliant When Equipped With Williams 4” WPRV/4T Intake Pressure Reducing Valve.

Basic System Includes:


• Jet Pump, Metering Valve, Check Valve, In-Line Strainer, Motive Water Control Valve, Control Panel and Block
Valves.

Materials of Construction:
• Brass, Stainless Steel and Stainless Steel Trim.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N13
www.williamsfire.com
components for fire apparatus

components for fire apparatus

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
N14
www.williamsfire.com

FIXED FOAM STORAGE AND PROPORTIONING SYSTEMS


SECTION INDEX
fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Spectrum Bladder Tanks-Vertical Configuration.........................................................................................................................O2-O4
Spectrum Bladder Tanks-Horizontal Configuration.................................................................................................................... O5-O7
Foam Systems- Typical Bladder Tank Piping Schematic.................................................................................................................O8
Single Tank Deluge System with Single Riser
Foam Systems- Typical Bladder Tank Piping Schematic.................................................................................................................O9
Dual Tanks (Main & Reserve) Deluge System with Single Riser
Foam Systems- Typical Bladder Tank Piping Schematic...............................................................................................................O10
Single Tank Deluge System with Three Risers
Typical Bladder Tank Piping Schematic..................................................................................................................................................O11
Single Tank Deluge, Wet Pipe, or Pre-Action System with Single Riser
Typical Bladder Tank Piping Schematic.................................................................................................................................................O12
Single Tank Deluge, Wet Pipe, or Pre-Action System with Three Risers
Vertical Polyethylene Storage Tanks..............................................................................................................................................O13-O14
Horizontal Polyethylene Storage Tanks.........................................................................................................................................O15-O17
Spectrum ATP Eductors, 2” & 3” - Grooved Type..................................................................................................................................O18
Spectrum Multi-Port Metering Valve - Air Actuated.........................................................................................................................O19
Spectrum Ratio Controllers, 2” & 2.5” -Threaded Type..................................................................................................................O20
Spectrum Ratio Controllers, 5” Grooved.................................................................................................................................................O21
Spectrum Ratio Controllers, 3”,4”,6”,8”- Wafer Style.......................................................................................................................O22
Ratio Controller Detail........................................................................................................................................................................... O23-O24
Hydraulically Actuated Foam Concentrate Control Valve- “Standard Port” Waterway............................................... O25
Hydraulically Actuated Foam Concentrate Control Valve- “Full Port” Waterway............................................................ O26
Electrically Actuated Foam Concentrate Control Valve- “Standard Port” Waterway.....................................................O27
Electrically Actuated Foam Concentrate Control Valve- “Full Port” Waterway................................................................ O28
Low Pressure Drop / Wide-Range Proportioner.............................................................................................................O29-O30
Pump Injection Type, with Ratio Controller on Skid...............................................................................................................O31-O32
Pump Injection Type, with Dual Ratio Controllers on Skid-Typical Configuration . ...................................................... O33
Inline Balanced Pressure Proportioning Modules.......................................................................................................................... O34
Inline Balanced Pressure Pump Skid - Typical Schematic.........................................................................................................O35
Inline Balanced Pressure Pump Skid-Single Pump Configuration.........................................................................................O36
Inline Balanced Pressure Pump Skid-.....................................................................................................................................................O37
Dual Pump (with Jockey Pump)/Dual Tank Configuration
Inline Balanced Pressure Pump Skid-Dual Pump.............................................................................................................................O38
Single Tank Configuration
Spectrum Back Pressure Control Valve.................................................................................................................................................O39
Spectrum Inline Balanced Pressure Proportioning Module...................................................................................................... O40
“Trimmed Configuration, Threaded Ratio Controller”
Spectrum Inline Balanced Pressure Proportioning Module.......................................................................................................O41
“Trimmed Configuration, Flanged Ratio Controller”
Inline Balanced Pressure Proportioner with Manual Override- General Arrangement Drawing............................O42
Spectrum Line Proportioners.............................................................................................................................................................O43-O44
Compatibility with AFFF Concentrates/Solutions...................................................................................................................O45-O46
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O1
www.williamsfire.com

Fixed Foam Systems & Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Bladder Tanks-Vertical Configuration

Description:
Spectrum Vertical Bladder tanks provide dependable and cost effective foam fire protection for a wide variety of
flammable/combustible liquid hazards. Used in conjunction with either one, or multiple ratio flow controllers (installed
adjacent to the tank), the all-hydraulic balanced pressure proportioning system stores, delivers and proportions foam without
dependence on external foam concentrate pumping. Only water under pressure is required for system operation.

The Spectrum Vertical Bladder Tank is a cylindrical carbon steel ASME pressure vessel containing a flexible polymeric
elastomer inner bladder which encapsulates the foam concentrate. This bladder physically separates stored foam concentrate
from the water supply. When the system is activated, water is directed into the tank shell, which then pressurizes the space
between the flexible bladder and the interior tank wall. This water pressure causes the bladder to collapse, which then dis-
penses foam concentrate out through distribution piping and (ultimately) into the ratio controller(s). The ratio controller’s
modified venturi creates a “metering pressure drop” in the fire water line, allowing foam concentrate to pass through a fixed
orifice plate and enter the fire water piping at the designated proportioning rate. In installations where the bladder normally
is under pressure (wet pipe, reaction, or when the deluge valve is downstream from the ratio controller), a normally-closed
actuated concentrate valve (electric or hydraulic) isolates the foam concentrate until energized. Interior/exterior finished in
red enamel.

Standard Spectrum Bladder tank trim includes:

1. ASME Code Pressure Vessel


2. Flexible Concentrate Bladder
3. Shell Side (water) Vent Valve
4. Bladder (concentrate) Vent Valves
5. Shell Side (water) Fill/Drain Valve
6. Bladder (concentrate) Fill/Drain Valve
7. Water Balancing Nozzle (screened)
8. Vessel Skirt with Anchors
9. Concentrate Discharge Pipe, Perforated
10. Lifting Lugs
11. Concentrate Discharge Nozzle

Spectrum Bladder Options:

12. Sight Gauge Assembly


13. Epoxy Interior/Exterior finish (For use in marine or
corrosive environments)
14. Pressure Relief Valve (Not Shown)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O2
www.williamsfire.com

Fixed Foam Systems & Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Vertical Bladder Tank Dimensions: 50-1500 Gallons

Dimensions Approx.
Nominal
Diameter Shipping
Capacity A B C D E F Weight
Gal. (L) in. (cm.) in. (cm.) in. (cm.) in. (cm.) in. (cm.) in. (cm.) in. (cm.) lb.
50 (190) 24 (61) 64 (163) 57 (145) 24 (61) 7.5 (19) 20 (51) 19 (48) 470
100 (379) 24 (61) 90 (229) 82 (208) 52 (132) 8.5 (22) 19 (48) 19 (48) 700
150 (568) 30 (76) 90 (229) 82 (208) 49 (125) 10.5 (27) 21 (53) 21 (53) 980
200 (767) 30 (76) 108 (274) 100 (254) 68 (173) 10.5 (27) 22 (56) 21 (53) 1290
300 (1136) 36 (91) 112 (284) 104 (264) 70 (178) 10.5 (27) 25 (64) 24 (61) 1550
400* (1514) 42 (107) 108 (274) 100 (254) 66 (168) 10.5 (27) 28 (71) 27 (69) 1800
400 (1514) 48 (122) 92.5 (235) 84.5 (215) 55 (140) 10.5 (27) 32 (81) 30 (76) 2250
500* (1893) 42 (107) 126 (320) 118 (300) 83 (211) 10.5 (27) 28 (71) 27 (69) 2150
500 (1893) 48 (122) 105.5 (268) 97.5 (248) 64 (163) 10.5 (27) 32 (81) 30 (76) 2500
600 (2271) 48 (122) 118 (300) 110 (279) 74 (188) 10.5 (27) 32 (81) 30 (76) 2570
700 (2650) 48 (122) 132 (335) 124 (315) 88 (224) 10.5 (27) 32 (81) 30 (76) 2840
800 (3028) 48 (122) 146.5 (372) 138.5 (352) 95 (241) 10.5 (27) 32 (81) 30 (76) 3200
800* (3028) 54 (137) 124 (315) 116 (295) 79 (201) 10.5 (27) 34 (86) 34 (86) 3100
900 (3407) 48 (122) 160.5 (408) 152.5 (387) 106 (269) 10.5 (27) 32 (81) 30 (76) 3400
900* (3407) 54 (137) 136 (345) 130 (330) 90 (229) 10.5 (27) 34 (86) 34 (86) 3400
1000 (3785) 48 (122) 174.5 (443) 166.5 (423) 116 (295) 10.5 (27) 32 (81) 30 (76) 3600
1000* (3785) 54 (137) 146 (371) 140 (356) 101 (257) 10.5 (27) 34 (86) 34 (86) 3600
1100 (4164) 60 (153) 144 (366) 136 (346) 90 (229) 18.5 (47) 37 (94) 36 (91) 3750
1200 (4542) 60 (153) 153 (389) 145 (368) 96 (244) 18.5 (47) 37 (94) 36 (91) 3950
1300 (4921) 60 (153) 162 (412) 154 (391) 104 (264) 18.5 (47) 37 (94) 36 (91) 4140
1400 (5300) 60 (153) 171 (435) 163 (414) 110 (279) 18.5 (47) 37 (94) 36 (91) 4350
1500 (5678) 60 (153) 180 (458) 171 (435) 117 (297) 18.5 (47) 37 (94) 36 (91) 4530

Tank Capacity Dim. “A” Dim. “B” Dim. “C” Dim. “D”
Gal. L. (Tank Dia.) in. cm. in. cm. hole Dia.
50-100 (190-379) 24 (61) 1.7 (4.5) 19.5 (49.5) 1 (2.5)
150-200 (568-757) 30 (76) 1.7 (4.5) 23.7 (60.2) 1 (2.5)
300 (1136) 36 (91) 1.7 (4.5) 28.0 (71.1) 1 (2.5)
400-500 (1514-1893) 42 (107) 2.2 (5.7) 33.0 (83.3) 1 (2.5)
400-1000 (1514-3785) 48 (122) 2.2 (5.7) 37.0 (94.0) 1 (2.5)
800-1000 (3028-3785) 54 (137) 2.2 (5.7) 41.5 (105.4) 1 (2.5)
1100-1500 (4164-5678) 50 (152) 2.2 (5.7) 47.0 (119.4) 1 (2.5)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O3
www.williamsfire.com
fixed foam systems and proportioning systems

fixed foam systems and proportioning systems

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O4
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Bladder Tanks-Horizontal Configuration

Description:
Spectrum Horizontal Bladder tanks provide dependable and cost
effective foam fire protection for a wide variety of flammable/combustible
liquid hazards. Used in conjunction with either one, or multiple ratio flow
controllers (installed adjacent to the tank), the all-hydraulic balanced pres-
sure proportioning system stores, delivers and proportions foam without
dependence on external foam concentrate pumping. Only water under
pressure is required for system operation.

The Spectrum Horizontal Bladder Tank is a cylindrical carbon steel


ASME pressure vessel containing a flexible polymeric elastomer inner bladder which encapsulates the foam concentrate. This
bladder physically separates stored foam concentrate from the water supply. When the system is activated, water is directed
into the tank shell, which then pressurizes the space between the flexible bladder and the interior tank wall. This water pres-
sure causes the bladder to collapse, which then dispenses foam concentrate out through distribution piping and (ultimately)
into the ratio controller(s). The ratio controller’s modified venturi creates a “metering pressure drop” in the fire water line,
allowing foam concentrate to pass through a fixed orifice plate and enter the fire water piping at the designated proportioning
rate. In installations where the bladder normally is under pressure (wet pipe, reaction, or when the deluge valve is downstream
from the ratio controller), a normally-closed actuated concentrate valve (electric or hydraulic) isolates the foam concentrate
until energized. Interior/exterior finished in red enamel.

Standard Spectrum Bladder tank trim includes:

1. ASME Code Pressure Vessel


2. Flexible Concentrate Bladder
3. Shell Side (water) Vent Valve
4. Bladder (concentrate) Vent Valves
5. Shell Side (water) Fill/Drain Valve
6. Bladder (concentrate) Fill/Drain Valve
7. Water Balancing Nozzle (screened)
8. Vessel Skirt with Anchors
9. Concentrate Discharge Pipe, Perforated
10. Concentrate Discharge Nozzle
11. Lifting Lugs included (not shown)

Spectrum Bladder Options:

12. Sight Gauge Assembly


13. Epoxy Interior/Exterior Finish (For use in
marine or corrosive environments)
14. Pressure Relief Valve (Not Shown)­

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O5
www.williamsfire.com

Horizontal Bladder Tank


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Tank Size A B C D E F G H Saddle
Width
Gal. (L) in. (cm) in. (cm) in. (cm) in. (cm) in. (cm) in. (cm) in. (cm) in. (cm) in. (cm)
100 (379) 16.0 (41) 32 (81) 35.5 (90) 0.75 (1.9) 5 (13) 10 (25) 18 (46) 0.63 (1.6) 3 (7.6)
150 (568) 18.0 (46) 36 (91) 35.0 (89) 0.75 (1.9) 8 (20) 16 (41) 24 (61) 0.63 (1.6) 3 (7.6)
200 (757) 20.0 (51) 40 (101) 44.0 (112) 0.75 (1.9) 8 (20) 16 (41) 24 (61) 0.63 (1.6) 3 (7.6)
300 (1136) 21.0 (53) 42 (107) 46.0 (117) 0.75 (1.9) 11 (28) 22 (56) 30 (76) 0.63 (1.6) 3 (7.6)
400* (1514) 21.0 (53) 40 (107) 44.5 (113) 0.75 (1.9) 14 (36) 28 (71) 36 (91) 0.75 (1.9) 4 (10.2)
400 (1514) 17.12 (43) 34.25 (87) 36.5 (93) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 0.88 (2.2) 4 (10.2)
500* (1893) 24.0 (61) 48 (122) 53.0 (135) 0.75 (1.9) 14 (36) 28 (71) 36 (91) 0.75 (1.9) 4 (10.2)
500 (1893) 20.62 (52) 41.25 (105) 43.0 (109) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 0.88 (2.2) 4 (10.2)
600 (2271) 22.5 (57) 45 (114) 49.5 (126) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 0.88 (2.2) 4 (10.2)
700 (2650) 26.0 (66) 52 (132) 56.5 (144) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 0.88 (2.2) 4 (10.2)
800 (3028) 30.62 (78) 61.25 (156) 63.5 (161) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 0.88 (2.2) 4 (10.2)
800* (3028) 24.0 (61) 48 (122) 52.2 (133) 0.88 (2.2) 20 (51) 40 (102) 48 (122) 1.0 (2.5) 4 (10.2)
900 (3407) 34.12 (87) 68.25 (173) 70.5 (179) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 0.88 (2.2) 4 (10.2)
900* (3407) 26.0 (66) 52 (132) 57.7 (147) 0.88 (2.2) 20 (51) 40 (102) 48 (122) 1.0 (2.5) 4 (10.2)
1000 (3785) 37.62 (96) 75.25 (191) 77.5 (197) 0.88 (2.2) 17 (43) 34 (86) 42 (107) 1.0 (2.5) 4 (10.2)
1000* (3785) 28.0 (71) 56 (142) 63.2 (160) 0.88 (2.2) 20 (51) 40 (102) 48 (122) 1.0 (2.5) 4 (10.2)
1100 (4164) 28.0 (71) 56 (142) 60.0 (152) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1200 (4542) 30.5 (78) 61 (155) 64.5 (164) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1300 (4921) 32.5 (83) 65 (165) 69.0 (175) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1400 (5299) 35.0 (89) 70 (178) 73.5 (187) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1500 (5678) 37.0 (94) 74 (188) 78.0 (198) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1600 (6057) 39.5 (100) 79 (201) 88.0 (234) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1700 (6435) 42.0 (107) 84 (213) 87.5 (222) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1800 (6814) 44.0 (112) 88 (224) 92.0 (233) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
1900 (7182) 46.5 (118) 93 (236) 96.5 (245) 0.88 (2.2) 23 (58) 46 (117) 54 (137) 1.0 (2.5) 4 (10.2)
2000 (7571) 36.0 (91) 72 (183) 72.2 (183) 0.88 (2.2) 29 (74) 58 (147) 66 (168) 1.0 (2.5) 4 (10.2)
2200 (8328) 39.0 (99) 78 (198) 81.7 (208) 0.88 (2.2) 29 (74) 58 (147) 66 (168) 1.0 (2.5) 4 (10.2)
2400 (9085) 42.5 (108) 85 (216) 88.2 (224) 0.88 (2.2) 29 (74) 58 (147) 66 (168) 1.0 (2.5) 4 (10.2)
2600 (9842) 45.5 (116) 91 (231) 94.7 (241) 0.88 (2.2) 29 (74) 58 (147) 66 (168) 1.0 (2.5) 4 (10.2)
2800 (10599) 48.5 (123) 97 (246) 100.7 (256) 0.88 (2.2) 29 (74) 58 (147) 66 (168) 1.0 (2.5) 4 (10.2)
3000 (11356) 52.0 (132) 104 (264) 107.2 (272) 0.88 (2.2) 29 (74) 58 (147) 66 (168) 1.0 (2.5) 4 (10.2)

*To be phased out after June 1996.

A E
D
B F
C G

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O6
www.williamsfire.com

Nominal Bladder Tank Dimensions Approx Shipping


Capacity Part No. Diameter A B C Weight
fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Epoxy/Enamel
Gal. (L) in. (cm) in. (cm) in. (cm) in. (cm) lb. (kg)
100 (379) 69090/69091 24 (61) 52 (132) 44 (112) 74 (188) 720 (330)
150 (568) 70521/70522 30 (76) 58 (147) 50 (127) 74 (188) 1050 (477)
200 (757) 69092/69093 30 (76) 58 (147) 50 (127) 91 (231) 1320 (600)
300 (1136) 69094/69095 36 (91) 64 (162) 56 (142) 96 (244) 1600 (725)
400* (1514) 69096/69099 42 (107) 70 (178) 62 (157) 93 (236) 2000 (908)
400 (1514) 419178/419179 48 (122) 76 (193) 68 (173) 77 (196) 2300 (1043)
500* (1893) 69098/69099 42 (107) 70 (178) 62 (157) 110 (279) 2350 (1066)
500 (1893) 419180/419181 48 (122) 76 (193) 68 (173) 90 (229) 2550 (1157)
600 (2271) 69100/69101 48 (122) 76 (193) 68 (173) 103 (262) 2800 (1270)
700 (2650) 69102/69103 48 (122) 76 (193) 68 (173) 117 (297) 3050 (1385)
800 (3028) 419182/419183 48 (122) 76 (193) 68 (173) 131 (333) 3250 (1474)
800* (3028) 69104/69105 54 (137) 82 (208) 74 (188) 109 (277) 3400 (1543)
900 (3407) 419184/419185 48 (122) 76 (193) 68 (173) 145 (368) 3420 (1551)
900* (3407) 69106/69107 54 (137) 82 (208) 74 (188) 120 (305) 3720 (1688)
1000 (3785) 419186/419187 48 (122) 76 (193) 68 (173) 159 (404) 3600 (1633)
1000* (3785) 69108/69109 54 (137) 82 (208) 74 (188) 131 (333) 3900 (1770)
1100 (4164) 71100/71101 60 (153) 88 (224) 80 (173) 123 (313) 4150 (1882)
1200 (4542) 71102/71103 60 (153) 88 (224) 80 (173) 132 (336) 4370 (1982)
1300 (4921) 71104/71105 60 (153) 88 (224) 80 (173) 141 (358) 4550 (2064)
1400 (5300) 71106/71107 60 (153) 88 (224) 80 (173) 150 (381) 4760 (2159)
1500 (5678) 71108/71109 60 (153) 88 (224) 80 (173) 159 (404) 4940 (2441)
1600 (6057) 71110/71111 60 (153) 88 (224) 80 (173) 169 (430) 5130 (2327)
1700 (6435) 71112/71113 60 (153) 88 (224) 80 (173) 178 (452) 5330 (2418)
1800 (6814) 71114/71115 60 (153) 88 (224) 80 (173) 187 (475) 5510 (2499)
1900 (7192) 71116/71117 60 (153) 88 (224) 80 (173) 196 (498) 5690 (2581)
2000 (7571) 71150/71151 72 (183) 100 (254) 93 (236) 154 (391) 6030 (2735)
2200 (8328) 71152/71153 72 (183) 100 (254) 93 (236) 166 (422) 6390 (2898)
2400 (9085) 71154/71155 72 (183) 100 (254) 93 (236) 180 (457) 6770 (3071)
2600 (9842) 71156/71157 72 (183) 100 (254) 93 (236) 193 (490) 7190 (3261)
2800 (10599) 71158/781159 72 (183) 100 (254) 93 (236) 205 (521) 7480 (3393)
3000 (11356) 71160/71161 72 (183) 100 (254) 93 (236) 218 (554) 7870 (3570)
Bladder Vent/Fill Valve
*To be phased out after June 1996.
C
Water Inlet
2.5 or 3 in. NPT*
Concentrate Outlet
Tank Shell
2.5 or 3 in. NPT*
Vent Valve

Bladder Lifting Lug

B Diameter

Water
Channel

Tank Shell
Drain Valve

Nameplate
Bladder
3 IN. (7.6 cm) Drain/Fill Valve 7 IN. (18 cm)

001161

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O7
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Foam Systems- Typical Bladder Tank Piping Schematic
Single Tank Deluge System with Single Riser

Note: Tank is not under pressure until system is activated

*Optional Valve- Actuated Ball Valve is required in this configuration only if Ratio Controller is installed at an eleva-
tion below the top flange of the Bladder Tank.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O8
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Foam Systems- Typical Bladder Tank Piping Schematic
Dual Tanks (Main & Reserve) Deluge System with Single Riser

Note: Tank is not under pressure until system is activated

*Optional Valve- Actuated Ball Valve is required in this configuration only if Ratio Controller is installed at an eleva-
tion below the top flange of the Bladder Tank.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O9
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Foam Systems- Typical Bladder Tank Piping Schematic
Single Tank Deluge System with Three Risers

Note: Tank is not under pressure until system is activated

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O10
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Typical Bladder Tank Piping Schematic
Single Tank Deluge, Wet Pipe, or Pre-Action System with Single Riser

Note: Tank is under constant system pressure.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O11
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Typical Bladder Tank Piping Schematic
Single Tank Deluge, Wet Pipe, or Pre-Action System with Three Risers

Note: Tank is under constant system pressure.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O12
www.williamsfire.com

Foam Concentrate Tanks


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Vertical Polyethylene Storage Tanks

Description:
Atmospheric High Density, Cross-Linked Polyethylene Storage Tanks are
an industry standard for storing foam concentrate. They are typically used in
conjunction with pumped balanced pressure systems or self-educting Hydro-
Foam™ monitor stations. Polyethylene is an exceptionally stable and durable
material when used to store foam concentrates. These rotationally molded,
corrosion/impact resistant upright tanks are available in nominal storage
capacities ranging from 55 to 12,000 gallons.

Bill of Materials
1 Pressure Vacuum Vent.
2 PVC Bulkhead Fitting.
3 10” Threaded Inspect Hatch (tank sizes
up to 400 gallons).
4 19” Bolted Manway (tank sizes >400 gal-
lons).
5 Top Mounted Fill Connection with PVC
Drop Tube (option).
6 Liquid Level Indication-Molded.
7 Tank Drain/Fill Fitting, Stainless Steel
Valved.
8 Pump Supply Fittings, Stainless Steel
with Siphon Pickup.
9 Return Fitting, Stainless Steel with
Siphon Discharge.
10 Fittings (only) for tank liquid level con-
tacts.

Pigments, Fittings, Liquid Level


Material Fittings
Vapor Space Liquid Space Indication
Vertical
Poly Tank High Density Molded into side
PVC or Stainless
Cross Linked <0.5% by weight Stainless Steel of (translucent)
Steel
Polyethylene tank

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O13
www.williamsfire.com

Foam Concentrate Tanks


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Vertical Polyethylene Storage Tanks- Dimensional Data

Nominal Vessel Capacities Capacities Diameter Height Wall Thickness Weight Top
Size in Gallons Str. Wall Total (bottom third) (less fittings) Opening
55 55 55 1’11” 3’5” .250 35# 10”
100 100 100 1’1” 5’4” .250 55# 10”
150 150 150 2’7” 4’6” .250 67# 10”
200 200 200 2’7” 5’10” .250 70# 10”
300 300 300 3’10” 4’4” .250 90# 10”
305 305 305 2’10” 6’10” .250 90# 10”
400 400 400 3’10” 6’ .250 120# 10”
525 497 557 5’4” 3’10” .250 185# 19”
550 550 574 4’ 6’7” .250 187# 19”
800 798 822 4’ 9’6” .250 200# 19”
805 805 865 5’4” 5’10” .250 200# 19”
1000 929 988 5’4” 6’8” .313 205# 19”
1100 1025 1178 7’1” 4’6” .250 190# 19”
1200 1156 1215 5’4” 8’ .313 260# 19”
1450 1325 1475 7’1” 6’ .313 280# 19”
1500 1458 1518 5’4” 9’10” .344 300# 19”
2000 1722 1945 8’ 5’11” .313 300# 19”
2500 2286 2508 8’ 7’4” .375 390# 19”
3000 2755 2977 8’ 8’9” .359 470# 19”
4000 3955 4159 7’10” 12’5” .500 720# 24”
4250 4120 4407 8’6” 11’3” .500 795# 19”
4300 4274 4905 11’11” 6’9” .375 1025# 24”
5000 5038 5241 7’10” 15’7” .656 1170# 24”
5500 5154 5509 9’2” 13’ .594 950# 24”
5500 5153 5508 9’2” 12’7” .594 950# 24”
6400 6056 6424 10” 12’ .500 960# 24”
6800 6835 7466 11’11” 10’ .625 1610# 19”
7000 7089 7665 10’ 14’3” .734 1310# 19”
8000 8317 8947 11’11” 11’8” .703 1650# 24”
10000 10120 10750 11’11” 14’ .906 2445# 24”
12000 12324 1294 11’11” 16’8” 1.047 3150# 24”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O14
www.williamsfire.com

Foam Concentrate Tanks


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Horizontal Polyethylene Storage Tanks

Description:
Atmospheric High Density, Cross-Linked Polyethylene
Storage Tanks are an industry standard for storing foam con-
centrate. They are typically used in conjunction with trans-
portable foam trailers, pumped balanced pressure systems or
self-educting Hydro-Foam™ monitor stations. Polyethylene
is an exceptionally stable and durable material when used
to store foam concentrates. These rotationally molded,
corrosion/impact resistant horizontal/cylindrical tanks are
available in sizes ranging from 110 gallons to 2,500 gal-
lons. Tanks are mounted on carbon steel support saddles and
secured with support bands.

Bill of Materials
1 Pressure Vacuum Vent.
2 PVC Bulkhead Fitting.
3 10” Threaded Inspect Hatch (tank sizes <
1000 gallons).
4 19” Bolted Manway (tank sizes >1000 gal-
lons).
5 Top Mounted Fill Connection with PVC Drop
Tube (option).
6 Liquid Level Indication-Molded.
7 Tank Drain/Fill Fitting, Stainless Steel Valved.
8 Pump Supply Fittings, Stainless Steel with
Siphon Pickup.
9 Tank Return Fitting, Stainless Steel with
Siphon Discharge.
10 Tank Return Fitting, Stainless Steel with
Siphon Discharge.
11 Fittings (only) for tank liquid level contacts.

Fittings, Fittings, Liquid Level


Material Pigments
Vapor Space Liquid Space Indication
Horizontal Poly
Tank High Density
PVC or Stainless Molded into side of
Cross Linked <0.5% by weight Stainless Steel
Steel (translucent) tank
Polyethylene

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O15
www.williamsfire.com

Foam Concentrate Tanks


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Horizontal Polyethylene Storage Tanks- Dimensional Data

Tank Configuration “A” (150-1000 Gallon Capacity)

Nominal Diameter Length Total Fill


Capacity Weight Opening
(US Gallons)
150 2’8” 4’10” 190 10”
200 x 32” 2’8” 5’8” 245 10”
200 x 38” 3’2’ 4’4” 245 10”
300 3’2’ 6’3” 305 10”
400 4’ 5’3” 330 10”
500 4’ 6’4” 350 10”
750 4’6” 7’1.5” 585 10”
1000 5’4” 7’2” 770 10” or 19”

Support Saddle “A1” - (150-500 Gallon Capacity)

Tank Size Width Length


150 31.5” 48”
200 x 32” 31.5” 60”
200 x 38” 37.5” 38.5”
300 37.5” 60”
400 48” 48”
500 48” 50”

Support Saddle “A2” - (750-1000 Gallon Capacity)

Tank Size Width Length


750 48.5” 65”
1000 57” 60”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O16
www.williamsfire.com

Foam Concentrate Tanks


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Horizontal Polyethylene Storage Tanks- Dimensional Data

Tank Configuration “B” (1025-2500 Gallon Capacity)

Nominal Capacity Diameter Length Total Weight Fill Opening


(US Gallons)
1025 4’ 12’4” 1065 19”
1625 5’4” 11’3” 1433 19”
2000 5’4” 13’1” 1550 19”
2500 5’4” 15’11” 1942 19”

Support Saddle “B”

Tank Size Width Length


1025 3’8.75” 9’10
1625 4’10” 9’3”
2000 4’10” 10’
2500 4’10” 14’6”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O17
www.williamsfire.com

Foam Systems - Around The Pump Eductors


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum ATP Eductors, 2” & 3” - Grooved Type

Description:
The Spectrum Around The Pump Eductor is a fundamental, eco-
nomical, yet proven way to produce foam on a fire truck. In operation a
portion of the fire water discharge is diverted to the eductor. The educ-
tor picks up foam concentrate from the on-board atmospheric foam tank
and delivers it to the suction side of the water pump. A metering valve
such as the Spectrum Multiport Metering Valve controls the amount of
concentrate entering the system. This, along with the rate of discharge,
determines the solution flow rate; typically from 1% to 6%. All dis-
charges in this type of system will produce foam solution. Eductors are
constructed of brass to provide years of trouble free service.

2” 3”
A 7.5” 10”

B 3.875” 5.0625”
C 2.8125” 2.6875”
D 2.625” 3.3125”
E 1.5” 2”
F 2” 3”
G 10” 15”

*Minimum straight pipe lengths


required upstream of controller

Minimum Operating Pressure = 75 psi


Maximum Operating Pressure = 225 psi

Maximum
Ratio Nominal Proportioning Drive Water
Part # Configuration Rates (gpm)
Controller Size Concentrate Flow Flow @ 200 psi
3% 6%
2.0EDCT-75 2” Grooved 75 gpm 2500 1250 85 gpm
3.0EDCT-150 3” Grooved 150 gpm 5000 2500 150 gpm

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O18
www.williamsfire.com

Foam Systems - Multi Port Metering Valve


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Multi-Port Metering Valve -
Air Actuated

Description:
The Spectrum Multi-Port Metering Valve offers the simplicity
and reliability of fixed orifice metering coupled with the flexibility
of eight (8) air actuated ports. The valve can be custom configured
to have from 1 to 8 ports. Each port can be selected to meter solu-
tion flows from 30 gpm @ 3% up to 750 gpm @ 6%. Each orifice
can easily be removed, replaced, added or changed in the field.
Each active port features a single acting spring loaded air actuator.
This air actuator features a manual over-ride that will allow the
system to manually function in the event of air system loss. The
construction is Red Brass with Stainless Steel trim and positive
rubber valve seats.

This valve is used in conjunction with the proper Spectrum


Eductor in an Around The Pump (ATP) Foam System. Primarily
used in Airport Crash Trucks, this system offers economic reli-
ability. As each discharge is opened an air signal is sent to the associated metering valve port. As each valve opens, more
predetermined amounts of concentrate enter the system to maintain either a 1, 3 or 6% proportioning rate.

Maximum Positive Pressure Rating is 25 psig

Part # Description Material


MVM01 Valve Body & Orifice Plate Bronze
MVM02 Air Actuated Valve Bronze
*MVM03-(Port#)-(Diameter) Orifice Insert Brass

*Contact Factory for Orifice Sizing

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O19
www.williamsfire.com

Foam Systems- Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Ratio Controllers, 2” & 2.5” -Threaded Type

Description:
Ratio Controllers are modified venturi foam proportioners that
accurately meter pressurized foam concentrate into the firewater stream.
These foam proportioners are used in conjunction with balanced pres-
sure systems, such as bladder tanks and pumped proportioning skids. In
operation, firewater flows through the modified venturi, creating an area
of lower pressure, which is referred to as the “metering pressure drop”.
This metering pressure drop is directly effected by the firewater velocity
as it flows through the venturi. The (1%, 3% or 6%) concentrate-to-water
ratio is maintained over the entire flow range of each size ratio control-
ler. However, each size ratio controller has a minimum flow rate/velocity
requirement, and these minimums must be maintained for proper ratio
controller operation.

Each Spectrum Ratio Controller consists of the following compo-


nents: body; metering orifice; inlet nozzle. These components are constructed of ASTM 85-5-5-5 bronze. The inlet nozzle
is tapered and machined to a smooth finish to maximize water stream efficiency through the venturi. The foam concentrate
metering orifice is sized to the exact type and percentage of foam concentrate to be used. Both the inlet nozzle and metering
orifice are secured by a stainless steel retaining ring.

2” 2.5”
A 2.375” 2.875”
B 7” 7”
C 2.0625” 2.0625”
D 3.75” 4.125”
E 10” 13”

*Minimum straight pipe lengths


required upstream/downstream of
controller.

Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet


Controller Size ATC Flow AFFF Flow (Fixed)
2” Threaded 80-200 gpm 40-200 gpm 1%/3%/6% 1”NPT (M)
2.5” Threaded 160-500 gpm 80-500 gpm 1%/3%/6% 1”NPT (M)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O20
www.williamsfire.com

Foam Systems- Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Ratio Controllers, 5” Grooved

Description:
The Spectrum 5” Grooved Ratio Controller is a modified
venturi foam proportioner that accurately meters pressurized foam
concentrate into the firewater stream. This foam proportioner is
used in conjunction with balanced pressure systems, such as blad-
der tanks and pumped proportioning skids. In operation, water
flows through the modified venturi, creating an area of lower pres-
sure, which is referred to as the “metering pressure drop”. This
metering pressure drop is directly effected by the firewater velocity
as it flows through the venturi. The (1%, 3% or 6%) concentrate-
to-water ratio is maintained over the entire flow range of the ratio
controller. However, each size ratio controller has a minimum flow
rate/velocity requirement, and these minimums must be maintained
for proper ratio controller operation.

The Spectrum Ratio Controller consists of the following components: body; metering orifice; inlet nozzle. These com-
ponents are constructed of ASTM 85-5-5-5 bronze. The inlet nozzle is tapered and machined to a smooth finish to maximize
water stream efficiency through the venturi. The foam concentrate metering orifice is sized to the exact type and percentage
of foam concentrate to be used. Both the inlet nozzle and metering orifice are secured by a stainless steel retaining ring.

Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet


Controller Size ATC Flow AFFF Flow (Fixed)
5” Victaulic™ or 400-1800 gpm 200-1800 gpm 1%/3%/6% 2”NPT (F)
Gruv-Lok™

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O21
www.williamsfire.com

Foam Systems- Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Ratio Controllers, 3”,4”,6”,8”- Wafer Style

Description:
Spectrum Ratio Controllers are modified venturi foam proportioners
that accurately meter pressurized foam concentrate into the firewater stream.
These foam proportioners are used in conjunction with balanced pressure
systems, such as bladder tanks and pumped proportioning skids. In opera-
tion, firewater flows through the modified venturi, creating an area of lower
pressure, which is referred to as the “metering pressure drop”. This metering
pressure drop is directly effected by the firewater velocity as it flows through
the venturi. The (1%, 3% or 6%) concentrate-to-water ratio is maintained
over the entire flow range of each size ratio controller. However, each size
ratio controller has a minimum flow rate/velocity requirement, and these
minimums must be maintained for proper ratio controller operation.

Designed to be installed between two 150# F.F. flanges, each Spectrum


Ratio Controller consists of the following components: body; metering ori-
fice; inlet nozzle. These components are constructed of ASTM 85-5-5-5
bronze. The inlet nozzle is tapered and machined to a smooth finish to maximize water stream efficiency through the venturi.
The foam concentrate metering orifice is sized to the exact type and percentage of foam concentrate to be used. Both the inlet
nozzle and metering orifice are secured by a stainless steel retaining ring. F.M. approved, File No. J.I.1R6A3.AF.

3” 4” 6” 8”
A 2.375” 2.5” 3.25” 3.5”
B 6.0625” 8” 12” 12”
C 2.625” 3.125” 4.125” 5.25”
D 1.25” 1.5” 2” 2.5”
E* 15” 20” 30” 40”
WEIGHT 10 lbs. 16 lbs. 32 lbs. 3 lbs.

*Minimum straight pipe length required upstream/


downstream of controller.

Ratio Configuration Nominal Nominal Proportioning


Controller Size ATC Flow AFFF Flow (Fixed)
3” Wafer, Between Flange 200-700 gpm 100-700 gpm 1%/3%/6%
4” Wafer, Between Flange 300-1250 gpm 175-1250 gpm 1%/3%/6%
6” Wafer, Between Flange 500-2500 gpm 350-2500 gpm 1%/3%/6%
8” Wafer, Between Flange 950-4500 gpm 700-4500 gpm 1%/3%/6%

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O22
www.williamsfire.com

Foam Systems- Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Ratio Controller Detail

Threaded - 2’ and 2.5”

Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet


Controller Size ATC Flow AFFF Flow AFFF Flow

2” Threaded
80-200 gpm 40-200 gpm 1% / 3% / 6% 1” NPT (M)
2.5” Threaded 160-500 gpm 80-500 gpm 1% / 3% / 6% 1” NPT (M)

Grooved - 5”


Ratio Configuration Nominal Nominal Proportioning Concentrate Inlet
Controller Size ATC Flow AFFF Flow AFFF Flow
5” Victaulic™ or 400-1800 gpm 200-1800 gpm 1% / 3% / 6% 2” NPT (F)
Gruv-Lok™

Wafer Style - 3”, 4”, 6”, 8”

Ratio Configuration Nominal Nominal Proportioning D


Controller Size ATC Flow AFFF Flow
3” Wafer, Between Flange 200-700 gpm 100-700 gpm 1% / 3% / 6% 1.25”
4” Wafer, Between Flange 300-1250 gpm 175-1250 gpm 1% / 3% / 6% 1.5”
5” Wafer, Between Flange 500-2500 gpm 350-2500 gpm 1% / 3% / 6% 2”
6” Wafer, Between Flange 950-4500 gpm 700-4500 gpm 1% / 3% / 6% 2.5”
01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O23
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Spectrum Ratio Controllers

Permanent Pressure Loss Data


Flow Rate (GPM)

MINIMUM INLET PRESSURE VERSUS WATER FLOW


psi
200
8 IN
4 IN

150
6 IN
3 IN

100

50
40

30
20

400 700 1000 2000 3000 5000 gpm


(1514) (2650) (3785) (7571) (11356) (18927) (Lpm)

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O24
www.williamsfire.com

Foam Systems Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Hydraulically Actuated Foam Concentrate Control Valve-
“Standard Port” Waterway

Description:
The Spectrum “Standard Port” Hydraulically Actuated Foam Concentrate Control
Valve is typically installed in the concentrate piping between the foam concentrate
storage tank and ratio controller (proportioner). When used in a balanced pressure
proportioning system, as well as most other foam concentrate applications, the valve
position is “normally closed,” preventing foam concentrate from entering into the
ratio controller. Upon system actuation, the valve will automatically open, supplying
foam concentrate to the specific (flowing) ratio controller.

Actuator Features
• Operating Medium- Water
• Connections-.25” (F) NPT
• Seal Material- O-Rings, Buna-N
• Rotational Arc, Max- 94 degrees
• Max Operating Pressure- 175 psi
• Position Indicator with Manual Override

Installation/Operation
The actuator is opened by introduction of system water pressure, and (therefore) requires no electrical power for opera-
tion. In most installations system water pressure is supplied to the actuator via .25” I.D. copper tubing, which is typically
connected to the trim of an automatic system valve (deluge, dry pipe, preaction).

Valve Features
• Ball valve, quarter-turn type with mounting pad.
• 600 psi WOG, cold, non-shock
• Threaded NPT (F) both ends.
• Reinforced TFE seats and stuffing box.
• Bronze body (standard) with stainless steel ball.

Std. Port Valve Waterway Minimum A B C D E F G


Model No. Size (port) Pressure
Diameter (actuator)
HBVS-1.0 1” .875” 25 psi 3.625” 2.5” 4.625” 3.25” 10.125” 7” 8”
HBVS-1.25 1.25” 1” 40 psi 3.625” 2.5” 4.875” 4” 10.375” 7” 8”
HBVS-1.5 1.5” 1.25” 50 psi 3.625” 2.5” 5” 4.375” 10.625” 7” 8”
HBVS-2.0 2” 1.5” 60 psi 3.625” 2.5” 5.125” 4.6875” 10.875” 7” 8”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O25
www.williamsfire.com

Foam Systems Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Hydraulically Actuated Foam Concentrate Control Valve-
“Full Port” Waterway

Description:
The Spectrum “Full Port” Hydraulically Actuated Foam Concentrate Control
Valve is typically installed in the foam concentrate piping between the foam concen-
trate storage tank and ratio controller (proportioner). When used in a balanced pres-
sure proportioning system, as well as most other foam concentrate applications, the
valve position is “normally closed,” preventing foam concentrate from entering into
the ratio controller. Upon system actuation, the valve will automatically open, supply-
ing foam concentrate to the specific (flowing) ratio controller.

Actuator Features
• Operating Medium- Water
• Connections-.25” (F) NPT
• Seal Material- O-Rings, Buna-N
• Rotational Arc, Max- 94 degrees
• Max Operating Pressure- 175 psi
• Position Indicator with Manual Override

Valve Features
• Ball valve, quarter-turn type with mounting pad.
• 600 psi WOG, cold, non-shock
• Threaded NPT (F) both ends.
• Reinforced TFE seats and stuffing box.
• Bronze body (standard) with stainless steel ball.

Installation/Operation
The actuator is opened by introduction of system
water pressure, and (therefore) requires no electrical
power for operation. In most installations system water
pressure is supplied to the actuator via .25” I.D. copper
tubing, which is typically connected to the trim of an
automatic system valve (deluge, dry pipe, preaction).

Std. Port Valve Waterway Minimum A B C D E F G


Model No. Size (port) Pressure
Diameter (actuator)
HBVF-1.0 1” 1” 50 psi 3.625” 2.5” 5” 3.625” 10.375” 7” 8”
HBVF-1.25 1.25” 1.25” 60 psi 3.625” 2.5” 5.125” 4.25” 10.625” 7” 8”
HBVF-1.5 1.5” 1.5” 75 psi 3.625” 2.5” 5.375” 4.75” 10.9375” 7” 8”
HBVF-2.0 2” 2” 130 psi 3.625” 2.5” 5.625” 5.375” 11.375” 7” 8”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O26
www.williamsfire.com

Foam Systems Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Electrically Actuated Foam Concentrate Control Valve-
“Standard Port” Waterway

Description:
The Spectrum “Standard Port” Electrically Actuated Foam Concentrate
Control Valve is typically installed in the foam concentrate piping between the
foam concentrate storage tank and ratio controller (proportioner). When used
in a balanced pressure proportioning system, as well as most other foam con-
centrate applications, the valve position is “normally closed, “ preventing foam
concentrate from entering into the ratio controller. Upon system actuation, the
valve will automatically open, supplying foam concentrate to the specific (flow-
ing) ratio controller.

Actuator Features
• Unidirectional through shafted design.
• Manual override, with valve position indicator.
• Permanently lubricated fully closed gear train.
• Water tight NEMA 4 enclosure.
• Prewired terminal strip.
• Maximum current requirements for open position
control - 11 amp @ 115V- 15 amp @ 24VDC.
• AC Voltages- (50 or 60 Hz), 24, 115, 220V.
• DC Voltages - 12, 24V.

Valve Features
• Ball valve, quarter-turn type with mounting pad.
• 600 psi WOG, cold, non-shock
• Threaded NPT (F) both ends.
• Reinforced TFE seats and stuffing box.
• Bronze body (standard) with stainless steel ball.

Standard Port Valve Size Waterway Standard A B C D


Model No. (port) Voltage
Diameter
EBVS-1.0 1” .875” 24 VDC 7” 3.375” 8.75” 5”
EBVS-1.25 1.25” 1” 24 VDC 7” 4.25” 9.125” 5”
EBVS-1.5 1.5” 1.25” 24 VDC 7” 4.75” 9.375” 5”
EBVS-2.0 2” 1.5” 24 VDC 7” 5.375” 9.75” 5”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O27
www.williamsfire.com

Foam Systems Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Electrically Actuated Foam Concentrate Control Valve-
“Full Port” Waterway

Description:
The Spectrum “Full Port” Electrically Actuated Foam Concentrate Control
Valve is typically installed in the foam concentrate piping between the foam
concentrate storage tank and ratio controller (proportioner). When used in a
balanced pressure proportioning system, as well as most other foam concentrate
applications, the valve position is “normally closed, “ preventing foam concen-
trate from entering into the ratio controller. Upon system actuation, the valve
will automatically open, supplying foam concentrate to the specific (flowing)
ratio controller.

Actuator Features
• Unidirectional through shafted design.
• Manual override, with valve position indicator.
• Permanently lubricated fully closed gear train.
• Water tight NEMA 4 enclosure.
• Prewired terminal strip.
• Maximum current requirements for open position
control - 11 amp @ 115V- 15 amp @ 24VDC.
• AC Voltages- (50 or 60 Hz), 24, 115, 220V.
• DC Voltages - 12, 24V.

Valve Features
• Ball valve, quarter-turn type with mounting pad.
• 600 psi WOG, cold, non-shock
• Threaded NPT (F) both ends.
• Reinforced TFE seats and stuffing box.
• Bronze body (standard) with stainless steel ball.

Standard Port Valve Size Waterway Standard A B C D


Model No. (port) Voltage
Diameter
EBVF-1.0 1” 1” 24 VDC 7” 3.375” 8.75” 8”
EBVF-1.25 1.25” 1.25” 24 VDC 7” 4.25” 9.125” 5”
EBVF-1.5 1.5” 1.5” 24 VDC 7” 4.75” 9.375” 5”
EBVF-2.0 2” 2” 24 VDC 7” 5.375” 9.75” 5”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O28
www.williamsfire.com

Williams’ ‘Flow Solution’


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Low Pressure Drop / Wide-Range Proportioner

The Williams’ ‘Flow Solution’ Proportioner Redefines Accurate/ Wide Range Balanced Pressure Foam
Proportioning and Control!

The Williams ‘Flow Solution’ has been developed to


address the Special Hazards Fire Protection Industry’s need
for an accurate wide-flow balanced pressure foam propor-
tioner which incorporates both low and constant pressure loss
with minimum water inlet pressure throughout its entire flow
range. In addition, these features are integrated into an assem-
bly, which also includes precise water and foam concentrate
control. The ’Flow Solution’ proportioner is configured as
an assembly which consolidates the following system com-
ponents: ratio controller; water control valve and (optional)
foam concentrate control valve with integral concentrate
check valve. Specifically suited for all closed head and
deluge foam sprinkler systems including auxiliary handline
discharges, the ‘Flow Solution’ proportioners’ revolutionary
design provides the following features:

Low, 8 PSI (nominal) Constant Pressure Loss


Throughout Entire Flow Range.

Wide Flow Range of 25gpm to 2500+gpm for Single Sprinkler Head to Total System Activation.

Low Minimum Inlet Pressure Requirement of 25 PSI Across Entire Flow Range

Configurable as Alarm Check or Water Control Valve

Fixed Proportioning of 1% or 3% with External Adjustment to Accommodate a Wide Range


of Foam Concentrate Viscosities.

‘Convertible’ 150# ANSI Flange / Grooved Water, Foam & Solution Connections

Nickel Plated Ductile Iron Body with Brass & Stainless Steel Trim

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O29
www.williamsfire.com
fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Ratio Controller Permanent Pressure Loss Comparison

Ratio Controller Inlet Pressure Comparison

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O30
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Pump Injection Type, with Ratio Controller on Skid

Description:
The Spectrum Pump Injection Type Balanced Pressure
Proportioning Skid is a completely self-contained system which
automatically proportions foam concentrate over a wide range of
flows and pressures, without manual adjustment. The skid is installed
adjacent to an atmospheric foam concentrate storage tank, and con-
sists of the following major components: positive displacement foam
concentrate pump; electric (or diesel) driver; pump starter/controller;
pressure balancing valve; ratio controller(s); duplex gauge; intercon-
necting pipe, valves, and fittings. In operation, foam liquid is drawn
from the atmospheric concentrate storage tank and pumped to the
skid-mounted ratio controller. The back-pressure type balancing
valve, installed on the tank return line regulates the amount of foam
concentrate which is returned to the storage tank, and balances the
foam concentrate pressure to match the water pressure at the ratio
controller. Water and foam pressures are monitored by a duplex
pressure gauge. Manual override of the system is accomplished through the use of a manual globe valve, installed in piping
which bypasses the diaphragm control valve. Field connections on the skid are limited to: water inlet to ratio controller; foam
solution discharge from ratio controller; electrical service to the pump motor starter/controller; foam concentrate suction and
return connections to the foam storage tank. All piping connections on the skid are 150# flanges.

Foam Storage Tank Pump Type Skid Concentrate Ratio Controller Standard
Piping Size(s) Proportioning
High Density Positive 1.5”-4” 3”-8” 1% / 3%
Polyethylene Displacement

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O31
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Pump Injection Type, with Ratio Controller on Skid

Piping Standard - Schedule 40 Carbon Steel Valve Standard - Bronze


Piping Options - Brass, Stainless Steel Valve Options - Stainless Steel
Pump Standard - Ductile Iron, Bronze Fitted Standard Proportioning - 1% or 3%
Pump Options - Bronze, Stainless Steel Standard Pump Controller - Limited Service, NEMA II
Standard Pump/Motor - Open Drip Proof 230 VAC/60/3 Enclosure

Nominal Nominal Pump Capacity gpm Horsepower


Ratio
Solution Solution (@200 PSI) (pump motor) Pipe
Model Controller Size
Flow ATC flow AFFF Size
AFFF (gpm) 1% 3% 1% 3%
(gpm) (gpm)
BPS-3L 200-600 100-600 3” 10 20 5 5 1.5”
BPS-3H 200-800 100-800 3” 12 30 5 7.5 1.5”
BPS-4 300-1250 175-1250 4” 15 40 5 10 1.5”
BPS-5 400-1800 200-1800 5” 20 60 5 15 2’
BPS-6L 500-2200 350-2200 6” 25 70 7.5 20 2’
BPS-6H 600-2500 350-2500 6” 30 80 7.5 25 2’
BPS-8L 950-2900 700-2900 8” 35 90 1.0 25 2.5”
BPS-8M 950-3800 700-3800 8” 45 120 10 30 2.5”
BPS-8H 950-4500 700-4500 8” 55 140 15 30 2.5”

Required Ordering Information: 5. Available Power Supply (voltage/cycle/phase)


1. Tank Capacity/Configuration 6. Piping Specification
2. Tank Material 7. Valve Specification
3. Type/Percentage of Foam Concentrate 8. Paint Specification
4. System Water Pressures (static/residual) 9. Foam System Flow Rate(s) - Minimum/Maximum
@Ratio Controller(s) Demand

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O32
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Pump Injection Type, with Dual Ratio Controllers on Skid-Typical Configuration

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O33
www.williamsfire.com

Balanced Pressure Proportioning Systems


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Inline Balanced Pressure Proportioning Modules

Description:
Spectrum Inline Balanced Pressure Proportioners (ILBP’s) com-
prise a complete foam storage, delivery and proportioning system,
when used in conjunction with properly sized atmospheric foam
tanks, foam pumps, back-pressure control valves and concentrate
distribution piping. When supplied with foam concentrate under
adequate pressure, they are designed to accurately introduce the
foam concentrate into the water stream over a wide range of flows
and pressures by automatically responding to variations in system
demand. ILBP’s provide accurate foam concentrate introduction
at either single/local, or multiple/remote system proportioning
location(s). Each ILBP system “riser” is calculated for system
demand and then equipped with the properly sized proportioner.

InLine Balanced Pressure System Schematic

Operation:
The Inline Balanced Pressure Proportioning System utilizes a foam pump, which pressurizes the distribution piping and
ultimately supplies foam concentrate to each ILBP. Foam concentrate is stored in an atmospheric foam tank. Pumped foam
concentrate that is not delivered to the system is returned to the storage tank via a back-pressure control valve. Concentrate
discharge pressure is regulated into the system by this control valve, which can be adjusted to assure that foam concentrate is
supplied at pressures that exceed system static water pressure. Concentrate supply piping should be designed and sized so that
residual concentrate pressure exceeds (15 psi minimum) the residual water pressure at the respective inlet of each ILBP.

A pressure throttling valve is located on the concentrate inlet trim of each ILBP. The pressure throttling valve senses
foam concentrate residual pressure and automatically modulates, resulting in the balancing of the concentrate pressure with
the water pressure. A duplex gauge provides the comparative readings of concentrate and water pressure at the ILBP inlets.
Foam concentrate is then introduced to the ratio controller (proportioner) at a pressure that is equal to (balanced with) the inlet
water pressure. A modified venturi in the ratio controller body creates a temporary pressure drop in the water stream, which
then meters the proper amount of foam concentrate into the system.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O34
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Inline Balanced Pressure Pump Skid - Typical Schematic

Piping Standard - Schedule 40 Carbon Steel Valve Standard - Bronze


Piping Options - Brass, Stainless Steel Valve Options - Stainless Steel
Pump Standard - Ductile Iron, Bronze Fitted Standard Proportioning - 1% / 3%
Pump Options - Bronze, Stainless Steel Standard Pump Controller - Per Schedule, NEMAII
Standard Pump/Motor - Open Drip Proof Enclosure
230 VAC/60/3

Maximum-3%
Pump Capacity Solution Flow (gpm) Horse power Piping Size Type of Pump
Model
(GPM)@ 200 PSI (pump motor) (concentrate) Controller
1% 3%
IBPS-40 40 4000 1320 10 1.5” Limited Service
IBPS-60 60 6000 1980 15 2” Limited Service
IBPS-80 80 8000 2640 25 2” Limited Service
IBPS-100 100 10000 3300 25 2” Limited Service
IBPS-120 120 12000 3960 30 2.5” Limited Service
IBPS-140 140 14000 4620 30 2.5” Limited Service
IBPS-150 150 15000 4950 30 3” Limited Service
IBPS-200 200 20000 6600 50 3” Full Service
IBPS-225 225 22000 7425 50 3” Full Service
IBPS-250 250 25000 8250 60 3” Full Service
IBPS-275 275 27500 9075 60 3” Full Service
IBPS-300 300 30000 9900 75 3” Full Service

Required Ordering Information:


1. Tank Capacity/Configuration 5. Available Power Supply (voltage/cycle/phase)
2. Tank Material 6. Piping Specification
3. Type/Percentage of Foam Concentrate 7. Valve Specification
4. System Water Pressures (static/residual) 8. Paint Specification
@Ratio Controller(s) 9. Foam System Flow Rate(s) - Minimum/Maximum demand

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O35
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Inline Balanced Pressure Pump Skid-Single Pump Configuration

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O36
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Inline Balanced Pressure Pump Skid-
Dual Pump (with Jockey Pump)/Dual Tank Configuration

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O37
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Inline Balanced Pressure Pump Skid-Dual Pump/Single Tank Configuration

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O38
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Back Pressure Control Valve

Description:
The Spectrum #108-2WF Back Pressure Control Valve is typically
installed on the foam concentrate pump-to-tank return line of a pumped bal-
anced pressure proportioning system. The pilot operated, diaphragm actuated
150# globe valve is designed to control foam concentrate pressure at the inlet
and is set to maintain a regulated pressure in the concentrate distribution pip-
ing which supplies one or more (remote or local) Inline Balanced Pressure
Proportioning Modules (ILBP’s). The valve’s diaphragm is nylon fabricated
(bonded with synthetic rubber), and forms a sealed chamber in the upper por-
tion of the valve, separating operating pressure from line pressure. The valve
automatically opens to relieve any pressure above its (adjustable) set point
and foam concentrate that is not delivered to the ILBP(s) is returned to the
concentrate storage tank. Standard inlet/discharge - 150# FF flange.

1 Basic Control Valve


2 Pressure Relief Pilot
3 Ejector, Fixed Restriction
4 Flow Control Valve
5 Sense Line Drain Orifice
6 Ball Valve- Sense Line Flush

Size Ductile Iron/ Bronze Stainless Steel A B C


Epoxy Coated
1.5” 108-2WF-1.5 DI 108-2WF-1.5 B 108-2WF-1.5 SS 8.5” 2.5” 12.375”
2” 108-2WF-2.0 DI 108-2WF-2.0 B 108-2WF-2.0 SS 9.375” 3” 12.375”
2.5” 108-2WF-2.5 DI 108-2WF-2.5 B 108-2WF-2.5 SS 10.5” 3.5” 14.375”
3” 108-2WF-3.0 DI 108-2WF-3.0 B 108-2WF-3.0 SS 10.5” 3.75” 14.625”
4” 108-2WF-4.0 DI 108-2WF-4.0 B 108-2WF-4.0 SS 13.5” 4.5” 16.375”

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O39
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Inline Balanced Pressure Proportioning Module
“Trimmed Configuration, Threaded Ratio Controller”

Description:
The Spectrum “Trimmed, Threaded” Inline Balanced Pressure
Proportioners (ILBP) is a completely self-contained factory
assembled and tested module. Used in conjunction with a foam
concentrate storage and pump system (refer to pages 38-41), each
Spectrum ILBP is designed to accurately introduce foam concentrate
into a dedicated water stream, over a range of flows and pressures.
Balancing is accomplished through the use of water and foam con-
centrate sensing lines, which are connected to the module’s pressure
throttling valve. Ultimately, foam concentrate is metered (propor-
tioned) into the water stream through a calculated orifice plate in the
ratio controller.

The “Trimmed” Spectrum ILBP System components include: threaded ratio controller, with integral concentrate orifice
plate (specify foam type and percentage); Spectrum Pressure Throttling Valve; duplex gauge (0-300 psi); concentrate inlet
pressure gauge; check valve; manual ball valve; sensing lines for water and foam concentrate and interconnecting brass foam
concentrate piping. Actuated concentrate valve (if required) is provided separately. Factory Mutual File No. J.I.1R6A3.AF.

Ratio
Foam Nominal ATC Nominal AFFF
Controller, Proportioning
Model Concentrate Flow Range Flow Range A B C*
Wafer Style (Fixed)
inlet trim (in GPM) (in GPM)
(Threaded)
ILBP-TT-2 2” 1” 80-200 40-200 1%/3%/6% 9” 7” 10”
ILBP-TT-2.5 2.5” 1” 160-500 80-500 1%/3%/6% 9” 7” 13”

* Minimum straight pipe lengths required upstream/downstream of controller.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O40
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Inline Balanced Pressure Proportioning Module
“Trimmed Configuration, Flanged Ratio Controller”

Description:
The Spectrum “Trimmed, Flanged” Inline Balanced Pressure
Proportioners (ILBP) is a completely self-contained factory assembled
and tested module. Used in conjunction with a foam concentrate storage
and pump system, each Spectrum ILBP is designed to accurately intro-
duce foam concentrate into a dedicated water stream, over a range of
flows and pressures. Balancing is accomplished through the use of water
and foam concentrate sensing lines, which are connected to the module’s
pressure throttling valve. Ultimately, foam concentrate is metered (pro-
portioned) into the water stream through a calculated orifice plate in the
ratio controller.

The “Trimmed” Spectrum ILBP System components include: wafer style ratio controller (flanged), with integral con-
centrate orifice plate (specify foam type and percentage); Spectrum Pressure Throttling Valve; duplex gauge (0-300 psi);
concentrate inlet pressure gauge; check valve; manual ball valve; sensing lines for water and foam concentrate and intercon-
necting brass foam concentrate piping. Actuated concentrate valve (if required) is provided separately. Factory Mutual File
No. J.I.IR6A3.AF.

Ratio
Foam Nominal ATC Nominal AFFF
Controller, Proportioning
Model Concentrate Flow Range Flow Range A B C
Wafer Style (Fixed)
inlet trim (in GPM) (in GPM)
(Flanged)
ILBP-TF-3 3” 1.25” 200-700 100-700 1%/3%/6% 9” 2.375” 15”
ILBP-TF-4 4” 1.5” 300-1250 175-1250 1%/3%/6% 10” 2.5” 20”
ILBP-TF-6 6” 2” 500-2500 350-2500 1%/3%/6% 10.25” 3.25” 30”
ILBP-TF-8A 8” 2” 950-4500 700-4500 1%/3%/6% 11.9375” 3.5” 40”
ILBP-TF-8 8” 2.5” 950-4500 700-4600 1%/3%/6% 11.9375” 3.5” 50”

* Minimum straight pipe lengths required upstream/downstream of controller.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O41
www.williamsfire.com

Foam Systems-Balanced Pressure Components


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Inline Balanced Pressure Proportioner with Manual Override-
General Arrangement Drawing

*Ordered Separately

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O42
www.williamsfire.com

Foam Systems- Line Proportioners (Eductors)


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Line Proportioners

Description:
Spectrum Line Proportioners provide both fundamental and
economical flammable fire protection, when properly designed and
installed into a fixed foam storage and distribution system. Line
Proportioners are constant flow, in-line devices that draw a fixed
amount of foam concentrate through a metering orifice into a pres-
surized water stream. They are available in a wide range of flow
rates. Foam solution outlet recovery is a nominal 65% of water inlet
pressure. Because they are back-pressure sensitive, each propor-
tioner must be precisely matched to the foam making “end-of-line”
devices.

System flow rate, as well as adequate residual pressure at each


nozzle are the primary design considerations when determining the
Line Proportioner water inlet pressure. Even through they are capable of operating at water inlet pressures as low as 70 psi,
most foam systems will require a minimum water inlet pressure of 100 psi, or greater. Line Proportioners are constructed of
cast brass and are equipped with either a 1% or 3% metering orifice (specify).

Line Proportioners are used in conjunction with an atmospheric foam storage tank. The storage tank trim should be
equipped with a top-mounted pressure vacuum vent, as well as properly-sized rigid foam concentrate suction piping with
slotted end, extending to near the tank bottom.

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O43
www.williamsfire.com

Foam Systems- Line Proportioners (Eductors)


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Product:
Spectrum Line Proportioners Performance & Dimensions


*Note: Mounts are not provided for Models #420 through #730

K Factor K Factor A B C D E F G H
1% 3% NPT (F) NPT (M)
LP-210 16.5 16.8 2.5” 1” 2.5” 2.69 16 4.25 8.5 4
LP-240 18.4 18.9 2.5” 1” 2.5” 2.69 16 4.25 8.5 4
LP-280 20.7 22.1 2.5” 1” 2.5” 2.69 16 4.25 8.5 4
LP-350 27.5 28 2.5” 1” 2.5” 2.69 16 4.25 8.5 4
LP-420 33.1 33.7 2.5” 1” 3” 2.97 18.38 4.75 n/a n/a
LP-480 38.1 38.7 2.5” 1” 3” 2.97 18.38 4.75 n/a n/a
LP-550 43.5 44.3 2.5” 1” 3” 2.97 18.38 4.75 n/a n/a
LP-600 47.5 48.5 3” 1.25” 4” 3.21 20.19 5.06 n/a n/a
LP-660 52.8 53.9 3” 1.25” 4” 3.21 20.19 5.06 n/a n/a
LP-730 57.8 58.8 3” 1.25” 4” 3.21 20.19 5.06 n/a n/a

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O44
www.williamsfire.com

Foam Systems- Materials of Construction


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Compatibility with AFFF Concentrates/Solutions

A. Superior material for equipment construction.


B. Suitable material for long-term exposure, a yearly spot check of material is advisable.
C. Not suitable for construction.

Material Type Material Type or Specific Identification Suitability with Suitability


Concentrate with
Water Solution Fresh or Sea
Water
Structural Plastics “Delrin” ® (acetal)* B B
Epoxy, fiberglass-reinforced B*** B***
Polycarbonate B A
Plexiglas (acrylic) B* A
Polyester, fiberglass-reinforced B** B**
Polyethylene, high density, cross-linked A A
Polyethyl ene, low density C A
Polystyrene C A
Polyvinyl Chloride (PVC) A* A
Polypropylene B A
Fluorocarbon Plastics A A
Baked or “Cold Set” Plastic Polyester: Flakeline ® 252 5 (50º-110º F Cure) A A
Coatings on Mild Steel Phenolic: “Heresite”® P-4033 A A
Phenolic: “Plasite”® #3055 or #3066, 9062,9570 A A
Epoxy-Phenolic (cold-set) “Plasite”*#7122, B A
Elastomers Ethylene-Propylene Terpolymer (EPT) A A
Rubber Seals EPDM A A
O-Rings Natural Rubber B A
Neoprene B B
Nitrile Rubber B A
Nylon Reinforced Nitrile A A
Lubricants Aluminum Complex Grease A A
“Lubriplast”® 630-2 A A
Packing Materials Asbestos 58106 A A
Metallic 100-M6 A A
Exterior Coatings “Plastite”®#71224 A A
‘Aquapon” UC422077 B A
“Imron’® Polyurethane Enamel1 B A
Pipe Sealants *Fel-Pro® C5A2 A A
(Dopes) 3M Sealer #4178 A A

® - Registered Trademarks
1. Dupont Company * Clear Plastic samples became opaque after exposure.
2. Fel-Pro Inc. ** Isophthalic based polyester gel coats required over fiberglass
3. Heresite and Chemical Company reinforced base.
4. Wisconsin Protective Coating Corp. *** Room temperature cured epoxy systems are not recom-
5. The Ceilcote Co. mended. Some heat cured systems, especially dicyandiamide
6. Crane Packing Co. catalyzed ones, have proven satisfactory.
7. PPG Industries

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O45
www.williamsfire.com

Foam Systems- Materials of Construction


fixed foam systems and proportioning systems

fixed foam systems and proportioning systems


Compatibility with AFFF Concentrates/Solutions

A. Superior material for equipment construction.


B. Suitable material for long-term exposure, a yearly spot check of material is advisable.
C. Not suitable for construction.

Metals Type Suitability with Suitability with Suitability with


Concentrate Fresh Water Sea Water
Aluminum- Anodized A A A
Uncoated B B C
Brass, CA-260(C2600) A A B
Bronze Cast A A A
80/10/10 (C93700)
85/5/5/5 (C83600)
Copper, Electrolytic, A A B
CA-110(C11000)
Copper, Nickel, 90/10 A A B
(C70600)
Iron, Cast SAE G-3500 B B B
Monel 400 A A B
Steel, Mild, 1010 B B B
Steel, Stainless 304 & 430 A A C
Titanium 6AL-4V A A A

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
O46
www.williamsfire.com

INTELLECTUAL PROPERTY
intellectual property

intellectual property
Patents Granted , Pending and Trademarks......................................................................................................................IP2

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
IP1
www.williamsfire.com

Intellectual Properties
intellectual property

intellectual property
The following are issued and pending patents which Williams Fire & Hazard Control, Inc® owns
and/or controls:

Issued
US4,640,461; US4,497,442; US4,705, 405; US4,781,467; US5,167,285; US5,275,243; US5,575,341; US5,312,041;
US4,828,038; US5,575,340; US5,566,766; US5,829,533; US5,913,366; US5,960,887; US5,779,159; US5,979,564;
US5,992,529; US6,065,545; US6,138,767; AUS555,644; EPO099,626; AUS616909; AUS621,264; EPO505,100;
AUS645,942; MEX181,130; AUS745869; SING72430; AUS745992; CA2,062,864; SING61278.

Pending
US09/284,561; US09/569,178; US09/593,360; US09/648,351; US10/081,419; US10/145,341; US10/147,647; US00/
26568; SAU92/20434; VZ2356/98; SAU99200049; AUS14142-97; CA2,277,828; EPO96944301.9; MX9900895; JAPH10-
506893; CA2,309,046; EPO98955034.8; MEX0003907; CA2,327,476; EPO98948538.8; MEX9763; PRC98814104.3;
EPO1,163,931; EPO1,186,320; JAP4-92469.

The following are registered trademarks of Williams Fire & Hazard Control, Inc®:

HIRED GUN; HANDGUN; PATRIOT I; PATRIOT II; HYDRO-CHEM; HYDRO-FOAM; HOT SHOT; FOOTPRINT; WILIAMS
FIRE & HAZARD CONTROL. INC®; PKW; WILLIAMS; THUNDERSTORM®, T-STORM®, ARMOR-LYTE™ .

For permission of use on the equipment and methodology, please contact Williams Fire & Hazard Control, Inc®

01152005

PRODUCT INFORMATION 24-HR EMERGENCY


409 - 745 - 3232 409 - 727 - 2347
IP2

Potrebbero piacerti anche