Sei sulla pagina 1di 2

Pressure Loss

Diameter Pipa Pressure Loss


3 inch 0.019507 psia/m
5 inch 0.003917 psia/m
7 inch 0.004518 psia/m

Temperature Loss

Diameter Pipa Temperature Loss


3 inch 0.0047 ºC/m
5 inch 0.0065 ºC/m
7 inch 0.0085 ºC/m

Pressure loss dan temperature loss didapat dari gradien grafik


𝑦 𝑃𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑇𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒 𝐿𝑜𝑠𝑠
K=𝑥= 𝐽𝑎𝑟𝑎𝑘

Perhitungan Pressure Loss pada Sumur Galih


Jarak menuju Manifold 1 Pressure Loss Pressure Akhir
Ratna 07 571 meter 11.13863265 363.8613673 psia
Ratna 08 259 meter 5.05237453 369.9476255 psia

Pressure loss didapat dari :

 571 meter x 0.019507 psia/meter = 11.138 psia


 259 meter x 0.019507 psia/meter = 5.052 psia

Jarak menuju Manifold 2 Pressure Loss Pressure Akhir


Manifold 1 1795 meter 7,030619629 352,9693804 psia
Ratna 09 941 meter 18,35631055 356,6436894 psia
Ratna 10 3818 meter 74,47863303 300,521367 psia
Ratna 11 2851 meter 55,61513431 319,3848657 psia
Ratna 12 3477 meter 67,82666502 307,173335 psia

Jarak Menuju GS Pressure Loss Pressure Akhir


Manifold 2 5476 meter 24,74230665 270,2576934 psia
Perhitungan Temperature Loss pada Sumur Galih
Jarak menuju Temperature Temperature
Manifold 1 Temperature Loss Akhir Rata2
Ratna 07 571 meter 2,6837 46,2053 C
46,9385
Ratna 08 259 meter 1,2173 47,6717 C
Temperature Rata2 F

116,4893

Jarak menuju Temperature Temperature


Manifold 2 Temperature Loss Akhir Rata2
Manifold 1 1795 meter 11,6675 35,271 C
Ratna 09 941 meter 4,4227 44,4663 C
Ratna 10 3818 meter 17,9446 30,9444 C 35,74362
Ratna 11 2851 meter 13,3997 35,4893 C
Ratna 12 3477 meter 16,3419 32,5471 C
Temperature Rata2 F

96,338516

Temperature
Jarak Menuju GS Temperature Loss Akhir
Manifold 2 5476 meter 46,546 25,4465 C

Pada jarak 1176 meter dipasang Heater WATTCO dengan settingan suhu 50ºC

Pada jarak 4705 meter dipasang Heater WATTCO dengan settingan suhu 32 ºC