Sei sulla pagina 1di 1

2/27/2019 How to Remove Pathogens from Water Systems : Pharmaceutical Guidelines

How to Remove Pathogens from Water Systems


The process to remove pathogens from the purified water system and water for injection system by sanitization.
Pathogens are the microorganisms which are capable the cause disease. All of these microorganisms are harmful to human. Those can survive into
the purified water as well as the water for injection. The pathogenic bacteria found in water system are E.coli, Salmonella and Pseudomanas.

Generally, these are attached in the filtration membranes of water system such as Reverse Osmosis membranes and Ultra-filtration membranes or
sometimes a biofilm can be formed in pipelines of the water system.

Sometimes when we analyze the purified water or water for injection (WFI) for the microbial limit test pathogens are found in the sample. In that
case, we should re-analyze the sample first to sure the occurrence the presence of pathogenic bacteria in the water system.

Related: Types of Water in Pharmaceuticals

When such a condition occurs the whole water system should be cleaned. First of all whole system should be sanitized with hot water (80⁰C) for a
period of 4-5 hours. All the user and sampling points should also be flushed by the continuous draining of hot water for 15-20 min to remove
pathogens properly.

Drain the water and flush the system at least two times with ¼ of the water storage tank. Fill the tank with fresh water. RO system and ultra-filtration
membranes should not be sanitized with hot water. This process is applicable only on water re-circulating loop connected with water storage tank.

Related: Cleaning and Disinfection of a New Purified Water System

After the sanitization, the sample should be taken from every user point and should be analyzed for all pathogens as per the standard operating
procedure for purified water/WFI testing.

If pathogens are found again in the water samples then the system should be sanitized first with the nitric acid solution (5%) followed by
formaldehyde, chlorine or hydrogen peroxide (5%) to remove pathogens. For the better results, these can be used with hot water.

Ultraviolet light in return loop plays a vital role to keep pathogenic bacteria away from the water system. The system should be cleaned properly and
should be analyzed for traces of the used chemically before using water in the manufacturing process.

Water system should be validated remove pathogens properly for a period of a minimum of seven days before using again in pharmaceutical
production.

Also see: Validation of Purified Water System

Ankur Choudhary is India's first professional pharmaceutical blogger, author and founder of Pharmaceutical Guidelines, a widely-read
pharmaceutical blog since 2008. Sign-up for the free email updates for your daily dose of pharmaceutical tips.
Need Help: Ask Question

Copyright © 2008-2019 Pharmaceutical Guidelines


Setup ❘ Terms of Use ❘ FAQ

https://www.pharmaguideline.com/2013/07/pathogenic-bacteria-removal-wfi-purified-water-system.html 1/1

Potrebbero piacerti anche