Sei sulla pagina 1di 2

MasterTop® 1210CP

High-build solvent free epoxy coating system for traffic deck protection

DESCRIPTION PACKAGING
MasterTop 1210CP is a multi component solvent
free epoxy coating system designed for application MasterTop P 651 25.4kg
at a total thicknesses between 1.0mm-2.0mm on MasterTop P 650 15kg
basement and ground floor car parks, or on MasterTop 1210CP (Neutral) 25.4kg
intermediate traffic decks exhibiting little or no MasterTop Color Pack 0.6kg
structural movement. MasterTop SR 3 25kg
MasterTop 1210CP may be applied to produce a MasterTop TC 444 18 litres
durable medium or heavy duty profiled finish. Optional UV top coats
MasterSeal TC 257 22.5kg
MasterSeal TC 258 24kg
PRIMARY USES
MasterTop 1210CP has good wear and abrasion
CONSUMPTIONS & DFT’S
resistance and is suitable for use on many traffic
deck applications.
Volume & kgs of Approx.
mixed resin (approx.) System DFT
MasterTop 1210CP provides a seamless coating
Medium Duty 0.75kg 0.5 litres 1.0mm
for concrete to protect against vehicle related Heavy Duty 1.1kg 0.70 litres 2.0mm
spillages such as common oils, greases, lubricants,
aviation fuels or A.C fluid. In addition it offers good
general chemical resistance, but as in all corrosive PHYSICAL PROPERTIES*
situations, a full analysis of operating and exposure
conditions is required, followed by reference to Pot life @25°C 40 mins
chemical resistance data to ensure product @40°C 22 mins
suitability. Curing time @25°C 15 hours
@40°C 10 hours
MasterTop 1210CP may used in the following Maximum service temp 60°C
applications: ** Flexural Strength ASTM C580 >40N/mm²
** Tensile Strength ASTM C307 >18N/mm²
 Car production and storage facilities.
 Aircraft hangars and maintenance areas. Dry 114,
Slip resistance BS 7976 Part 2
Wet 64
 Car workshops
 Traffic decking Bond strength ASTM D4541 >2.0N/mm²
 Pedestrian walkways **tested at 25°C

NB This gives examples only and does not EQUIPMENT CARE


constitute a full and comprehensive list. For further Remove uncured MasterTop 1210CP from tools
information on application possibilities contact and equipment using MasterTop THN 2.
BASF Construction Chemicals UAE LLC.
STORAGE
ADVANTAGES Store out of direct sunlight, clear of the ground on
 Good wear and abrasion resistance. pallets protected from rainfall. Avoid excessive
 Easily applied. compaction and protect from extremes of
 Profiled finish for slip resistance temperatures. In tropical climates the product must
 Good general chemical resistance. be stored in an air conditioned environment.
 Limited maintenance.
MasterTop® 1210CP
Estimating Guide Mixed pack weights (kgs) Application rate (kg/m²) (ltr/m²)
Medium duty Heavy duty
Primer / Sealer Coat
MasterTop P 651
(for more dense, less porous substrates, use 25.4kg N/A 0.3-0.35kg/m²
MasterTop P 650 primer)
MasterTop P 650 15kg N/A 0.15-0.30kg/m²
1st Coat Application
MasterTop 1210CP with 0.25kg/m² 0.55kg/m²
26kg
MasterTop Color Pack (0.6 kg) (0.16 ltrs/m²) (0.35 ltrs/m²)
MasterTop SR 3 Aggregate for broadcast 25kg 0.6kg/m² 2.0kg/m²
2nd Coat Application
MasterTop 1210CP with 0.50kg/m² 0.55kg/m²
26kg
MasterTop Color Pack (0.6 kg) (0.32 ltrs/m²) (0.35 ltrs/m²)
Optional UV resistant top coat
Optional 1 - MasterSeal TC 257 22.5kg 0.25kg/m² 0.25kg/m²
Optional 2 - MasterSeal TC 258 24kg 0.25kg/m² 0.25kg/m²
Note: Refer to the Method Statement for Thin Section Epoxy Repairs if required for a scratch coat to be applied using
MasterTop P 650.

LINEMARKING (100mm Wide) NOTE


MasterTop TC 444 Field service, where provided, does not constitute
Standard supervisory responsibility. For additional
Line Marking Coating (Smooth) information contact your local BASF
1st coat - 0.025 litre / lm representative.
(100mm Wide) - Approx. 100 microns
Allow approx. 2 hours between coats. (Touch Dry) BASF reserves the right to have the true cause of
2nd coat - 0.025 litre / lm any difficulty determined by accepted test
(100mm Wide) - Approx. 100 microns methods.
Light Reflectivity (Optional)
Line Marking Coating + Reflective Glass Beads QUALITY AND CARE
Refer to the BASF Technical Service Department All products originating from BASF’s Dubai, UAE
for a Project Specific Method Statement. facility are manufactured under a management
system independently certified to conform to the
SAFETY PRECAUTIONS requirements of the quality, environmental and
As with all chemical products, care should be occupational health & safety standards ISO 9001,
taken during use and storage to avoid contact with ISO 14001 and OHSAS 18001.
eyes, mouth, skin and foodstuffs (which can also
be tainted with vapour until products is fully cured * Properties listed are based on laboratory controlled tests.
or dried). Treat splashes to eyes and skin
® = Registered trademark of the BASF-Group in many countries.
immediately. If accidentally ingested, seek
medical attention. Reseal containers after use.
BASF_CC-UAE/Top_1210CP_07_04/v5/06_17
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


Disclaimer: the LRQA mark relates
P.O. Box 37127, Dubai, UAE to certified management system and
Tel: +971 4 8090800, Fax: +971 4 8851002 not to the product mentioned on this
www.master-builders-solutions.basf.ae datasheet

Potrebbero piacerti anche