PUNCHING DESIGN SUMMARY - TOP REBAR CHECK- 250 x 250 COLUMNS

1.60

1.55
1.52
1.50

1.45

1.40

1.35

1.30

1.25

1.20

1.15

1.10

1.05
1.01
1.00

0.95
PUNCHING STRESS (MPa)

0.90

0.85
CONCRETE
0.80
CAPACITY BASED ON H25 -200 + H32 - 200
(ADDITIONAL)
CONCRETE0.75
CAPACITY BASED ON H25 -200 + H25 - 200 (ADDITIONAL)

CONCRETE0.70
CAPACITY BASED ON H25 -200 + H20 - 200 (ADDITIONAL)
0.65

0.60
CONCRETE CAPACITY BASED ON H25 -200
0.55

0.50

0.45

0.40

0.35

0.30 0.29

0.25

0.20

0.15
0.12
0.10

0.05

0.00
0 100 200 300 400 500 600 700 800

PUNCHING FORCE (kN)


PUNCHING DESIGN SUMMARY - TOP REBAR CHECK- 250 x 500 COLUMNS

0.90

0.85 0.83

0.80

0.75 0.75
0.74

0.70
CONCRETE CAPACITY BASED ON H25 -200 + H32 - 200 0.68
(ADDITIONAL)
0.65 0.64
0.63
CONCRETE CAPACITY BASED ON H25 -200 + H25 - 200 (ADDITIONAL)
0.61
0.60
CONCRETE CAPACITY BASED ON H25 -200 + H20 - 200 (ADDITIONAL)
0.55

0.50
PUNCHING STRESS (MPa)

0.50
0.49
CONCRETE CAPACITY BASED ON H25 -200
0.47
0.45

0.40

0.37
0.35

0.30

0.25

0.20
0.18

0.15

0.10

0.05

0.00
0 500 1000 1500 2000 2500

PUNCHING FORCE (kN)


PUNCHING DESIGN SUMMARY - TOP REBAR CHECK - 300 X 500 COLUMNS

1.35

1.30
1.27
1.25

1.20

1.15

1.10

1.05 1.03

1.00

0.95

0.90

0.85

0.80
PUNCHING STRESS (MPa)

0.75
0.72

0.70 0.70
CONCRETE CAPACITY BASED ON H25 -200 + H32 - 200 (ADDITIONAL)
0.65
CONCRETE CAPACITY BASED ON H25 -200 + H25 - 200 (ADDITIONAL)
0.60
CONCRETE CAPACITY BASED ON H25 -200 + H20 - 200
0.55
(ADDITIONAL)

0.50
CONCRETE CAPACITY BASED ON H25 -200
0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.00
0 500 1000 1500 2000 2500 3000 3500 4000 4500

PUNCHING FORCE (kN)


PUNCHING DESIGN SUMMARY - BOTTOM REBAR CHECK

1.25

1.20 1.20
1.17
1.15

1.10

1.05

1.00

0.95

0.90
0.86
0.85

0.80

0.75
PUNCHING STRESS (MPa)

0.70

0.65
CONCRETE CAPACITY BASED ON H25 -200 + H32 - 200
(ADDITIONAL)
0.60
0.59
CONCRETE CAPACITY BASED ON H25 -200 + H25 - 200 (ADDITIONAL) 0.59
0.55
CONCRETE CAPACITY BASED ON H25 -200 + H20 - 200 (ADDITIONAL) 0.54
0.50 0.50

0.45
CONCRETE CAPACITY BASED ON H25 -200
0.43
0.39
0.40

0.35
0.34

0.30

0.25 0.26

0.20

0.15

0.10

0.05

0.00
0 500 1000 1500 2000 2500

PUNCHING FORCE (kN)