Sei sulla pagina 1di 1

CL

4700mm (CARRIAGEWAY) 4700mm (CARRIAGEWAY)


SHOULDER
10000 1.5
9400
1.831 1.0

250
60mm Thk. WEARING COURSE 1.693

154
(STREAM BED LEVEL) RFL 2.538

60
2.409 (STREAM BED LEVEL)

53
-0.37% -2.5 % 2.359
RUBBLE PAVING IN 1: 3 CEMENT SAND
MORTAR,PAVING TO BE DONE WITH SELECTED

250
CAMBER FORMED WITH RUBBLE OR GRADE 15(19) CONCRETE HAVING A
FLAT TOP SURFACE

150

150
GR.30(19) CONCRETE
EX.C-2.279
150
IL 0.549 150 GR.30(19) CONCRETE
IL 0.599 SURFACE TO BE RAMMED

15
Slope 1:200 (RHS)
(LHS) AND LEVELLED BEFORE

0
250

COMMENCING PAVING

1560
GR.30(19) CONCRETE
500

500
200 1200 200
150 150
75 Thk.15(37.5) CONC.

150
SCREED

150
SECTION A-A

450
(SCALE 1:100) 75 THK.15(37.5)
CONC. DETAIL OF RUBBLE
SCREED
PAVING AT WING WALL

200
450 ( SCALE 1:50 )
SECTION C-C
(SCALE :- 1:50)

1452
200

750 CL 750
1500

1500
TURFING / RUBBLE
PITCHING/GR.15(19) CONCRETE
(TO BE DECIDED)
200
200 TO KODIKAMAM 200

1810
2000

2000
1850

1850

GUARD STONE
DRG. NO. JF/01/CUL/SCB/02 2000 2000
200

1850 1850 150

CARRIAGEWAY LEVEL
200 200

150
CH.3+750

200
1200

75 THK.15(37.5)

1810
3000

CONC.

75
750 SCREED
1500
200

TYPICAL WING WALL SECTION (B-B)


1850

1850
2000

2000

200
( SCALE 1:50 )

700
75 Thk.15(37.5) CONC.
SCREED
3000
END ELEVATION
FROM PULOLY
1500

1500

( SCALE 1:100 )
750 750
NOTES:

PLAN 1. ALL DIMENSIONS ARE IN MILLIMETRES & ALL LEVELS ARE IN METERS ABOVE MEAN SEA LEVEL (MSL).

( SCALE 1:100 ) 2. ALL WORKS SHALL BE CARRIED IN CONFORMITY WITH RELEVANT SPECIFICATIONS.

3. ALL REDUCED LEVELS SHALL BE IN METERS.

4. FOUNDATION LEVELS BELOW INVERT LEVELS GIVEN ARE INDICATIVE ONLY. THE ACTUAL LEVELS
SHALL BE DECIDED AFTER EXCAVATION FOR THE FOUNDATION ARE CARRIED OUT.

5. FOR R/F DETAILS GRADE OF CONCRETE AND CLEAR COVER TO R/F ARE AS PER GIVEN DETAILS.

6. MINOR CHANGES MAY BE CARRIED OUT AT SITE AS DIRECTED BY THE ENGINEER.

7. IF WEAK SOIL STRATA IS ENCOUNTERED AT BASE SLAB LEVEL PREPARATION OF SAND BED SHALL BE
INTRODUCED AS INSTRUCTED BY ENGINEER.

8. a,b,c,d,e,f & g REFER TO COORDINATES.

DRAWING TITLE : CONTRACTOR ENGINEER


PROJECT:
EMPLOYER: ENGINEER: CONTRACTOR: DETAILS OF SINGLE CELL BOX CULVERT NAME DESIGNATION SIG. NAME DESIGNATION SIG.
REHABILITATION AND IMPROVEMENT ON [RECONSTRUCTION] CHECKED &
SURVEYED BY H.A.S.ABEWIKRAMA Surveyor
MINISTRY OF MEGAPOLIS & WESTERN RESOURCES DEVELOPMENT PULOLY-KODIKAMAM KACHCHAI ROAD CHAINAGE:- 3+750 REVIEWED BY
DEVELOPMENT CONSULTANTS PVT LTD. (AB31) PROJECT REV. DATE SIGN. DESCRIPTION DRAWN BY D.HARSHANA Draughtsman CERTIFIED BY
STRATEGIC CITIES DEVELOPMENT PROJECT 55 - 2/1, MAGA ENGINEERING PVT LTD.
4th. FLOOR , SETHSIRIPAYA-STAGE I , GALLE ROAD , CONSTRUCTION ENGINEERS CH 00+000 - CH 14+300 CHECKED BY K.L.S.N.FERNANDO C.M. APPROVED BY
BATTARAMULLA , COLOMBO 3, 200,NAWALA ROAD,
NARAHENPITA, SUBMITTED BY S.A.A.JAYASIRI P.M. DATE
SRI LANKA . SRI LANKA.
Tele. - 0112887320 - 2 , FAX. 0112868188 COLMBO 05. CONTRACT NO : SCDP/WB/WK/JF/01
DATE 2019.02.01 SCALE: AS SHOWN DWG. NO: JF/01/SCB/01