VR VR
The four timer sections in the 558 are edge-triggered; therefore,
TRIGGER A 3 TRIGGER D
when connected in tandem for sequential timing applications, no COMP COMP 14
coupling capacitors are required. Output current capability of 100mA
is provided in both devices. CONTROL
4 VR 13 RESET
VOLTAGE
VCC R1 R2
5 12 GROUND
FEATURES
• 100mA output current per section COMP COMP
TRIGGER B 6 11 TRIGGER C
• Edge-triggered (no coupling capacitor) VR VR
APPLICATIONS
• Sequential timing
• Time delay generation
• Precision timing
• Industrial controls
• Quad one-shot
ORDERING INFORMATION
DESCRIPTION TEMPERATURE RANGE ORDER CODE DWG #
16-Pin Plastic Small Outline Large (SOL) Package 0 to +70°C NE558D 0171B
16-Pin Plastic Dual In-Line Package (DIP) 0 to +70°C NE558N 0406C
RESET
TIMING
+ 3V
VCONTROL
TRIGGER
OUT
GND
VCC
TRIGGER
R1 RL R1 RL R1 RL R1 RL
OUTPUT 1
T T T T
C1 C1 C1 C2
OUTPUT 2
TRIGGER TR 0 TR 0 TR 0 TR 0 OUTPUT 3
OUTPUT 4
TDELA TOUTPUT
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 Y
TDELAY 3(R1C)
NOT USED
TOUT R2C2)
VCC
R1 RL R1 RL R1 RL R1 RL
2 C1 7 C1 10 C1 15 C1
5 TIME TIME TIME TIME
3 1 6 8 11 9 14 16
START TRIG 0 TRIG 0 TRIG 0 TRIG 0
1 2 3 4
13 13 13 13 12
RESET
10K
a. Ring Counter
VCC
START
RESET
01 T = RC
02
03
04
b. Expected Waveforms
Figure 2.