STRUCTURAL DESIGN NOTE

OF

GOA HAAT (POD)

AT

MERCES, GOA
CONTENT
1. LOAD DATA
2. STAAD INPUT
3. STAAD OUTPUT
4. FOUNDATION DESIGN
5. ANCHOR BOLT & BASE PLATE DESIGN
6. DRAWINGS
ROARK Part of Structure : GOA HAAT
CONSULTING ENGINEERS
Ref Calculations Sheet.
Building Type = OS
Length( l ) (c/c) = 20.00 m
Width( w ) (c/c) = 15.00 m
Bay spacing = 1.25 m
Clear Height = 26.00 m
Max. eave hight( h ) = 26.00 m
Roof slope ( ) = 0.00

DEAD LOAD (DL)


S/W of G.I Sheet = 15 Kg/m2
S/W of Purlin = 10 Kg/m2
S/W of Purlin Connection( = 5 Kg/m2
Bolts+Sag Rod +Flange Plate )
Misc. Load = 20 Kg/m2

Total Dead Load = 50 Kg/m2

LIVE LOAD (LL)

Live load = 75.00 Kg/m2 (As per table 2.1, IS:875 Part 2)

WIND LOAD (WL)


VZ = K1 x K2 XK3 X K4 x Vb (As per Cl.6.3, IS:875 Part 3)
Vb = 39 m/sec (As per Cl.6.3, IS:875 Part 3)
K1 = 1 (As per T able-1, IS:875 Part 3) (AVERAGE LIFE 50 Yrs)
K2 = 1.12 (As per T able-2, IS:875 Part 3) (TERRAIN CATEGORY III)
K3 = 1 (As per Cl.6.3.3.1, IS:875 Part 3)
K4 = 1 (As per Cl.6.3.4, IS:875 Part 3)
VZ = 43.68 m/sec

PZ = .6 x VZ x VZ n/m2 (As per Cl.7.2, IS:875 Part 3)


PZ = 1.144765 KN/M2

Pd = Kd x Ka xKc x Pz Kn/m2 (As per Cl.7.2, IS:875 Part 3)


kd = 0.9 (As per Cl.7.2.1, IS:875 Part 3)
ka = 0.9 (As per T able-4, IS:875 Part 3)
kc = 0.9 (As per Cl.7.3.3.13, IS:875 Part 3)
Pd = 0.834534 KN/M2
STAAD INPUT
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Sep-18 Chd

Client File GOA POD- R16.std (FINALDate/Time


)-R1.std 11-Dec-2018 16:47

3D Rendered View

Print Time/Date: 11/12/2018 17:11 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 5
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date11-Sep-18 Chd

Client File GOA POD- R16.std (FINALDate/Time


)-R1.std 11-Dec-2018 16:47

783
779
775476 408 466
435
774
773
434 407 439
772 406
771 218 405 438
770 433 404 437
777 430 403 341
776 429402 14
737 416 13
756736 735
418
196 12
725 417
415 15
286
285 16
726 414
321284
686 413
197 17
757 766 727 412 18
728 198 20
411 19
687 685 729
134 625
785
345
199 21
784
200 22
322340
730 492
626
627
201
628
629
489
409
487
23
731
133 670 202 630
631
632 24
25
26
27
28
30
702 762 684 758 748135 32
35
701826 825683 824 829 828 747 830
827 831 732
669823
591
733
203
116
204
761 613
595 115
205
612
734 348
206
703 746597596 297 296 614
700 760 682 759 749593592
151 323
132 668295 349
594150327131 114
336
769 704 699 688 681 814651 750 326 819 298
710818 817 816 815680 152 820 745
813 324
821
130576
667 113 350
822 589
575 588
723 711 718 698 689 679 650 751 149325 74456859 299 335
294
722
81 712 649 572571 570129 666 112 353
719 678 400573 148 743 137 12858300 293
709
721 717 574 647153
161 505
663 805690 804677 646 292
662 720 713
708 807697
806716 803162 801 752 810 742127 811
57
809812 832
615 504
802 808 176
175 163 64417014713812655 548
564
547 562
291
660 707 676
172 741
537 30136 354
664 661 659 714 715 696 171 643 169 753
541 540125 54 290
706 691 675
158 642
174 544 542146 139 74052 503 355
107
538 546 543164
157 167 754 289
302
665 658 705 695 692 106 173 786 755 124 51
617
237 618 619
789
620
790 621622
792
791 793623795 798 797 674
624
794 104796156 800145799123 739
535
50
536303333
288
843
788
787 694109 105 103 639
657 166 140520 519 304
165 155 764515 496 738287 357
655 673 141122329
693 102 517516
154
110 654509 510 511512
672
6 7
513911 144763 47178
514
638 358
507 5083 4 5 143 120
66 328
506
1 2 637 46
780 653 64 142 359
63663 119 45331
656671 44 360
63562118
652 634 65 43 370 361
444 6142501
633 842
781 40
60 841 362

500
499
445 837 363839
782 367
835 836
497
446 833 834
365
848
450
463
849
Y 847
X Z
447 Load 101
845

NODE NUMBER

Print Time/Date: 11/12/2018 17:11 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 2 of 5
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date11-Sep-18 Chd

Client File GOA POD- R16.std (FINALDate/Time


)-R1.std 11-Dec-2018 16:47

1069
1062
1061 1052
1051 864 489
1060
1050 411 457
1049
10481059 461 410
1063
1047 1058 460 409 456
408 455
459
1057 881 407 458 454
1056 880 406 465 453
1055 1036 882425438
1005 437 9
10461004 1334 883 424 8
884 421 422
334 10
1045 1003 993
423
885 420 11
272
405
1024 1035 1054 271
886 12
994 270 419 13
1044950 887
181 41841314
995404 888 417
996 313333 889
182
1072 41616 15
1025 1034 1016
119997 1073 1071
183
890415
1070
184 17
514
516
1043951 949 403 9981053 891
892
893414
894 513
512
18
999 185
895
896 19
20
21
22
412
23
897
25
966 1078 1077 1076
1156131911551075 1159 10741000
935
332 283 27
186
1079
1328 1158
1316
1150
1030 13171157
1149
948 1318
1148 1147 1320 1154
1146 1321
1161
11601322
314 1151
1145
1001
1243187
343
188
868
102
1042 13331026 1017 402 1015
118 934 720
759 726
189
1315
1002
760
537
1314 190
965 120 722 721747
1313
750 758
1196
538101191
1029 947 723 751
1311 1312
539 282 344
1238
725
135 724
755
1309 753
1310
541 540 330
1041
967 964 1028 946 1027401 1247542
1018 319 117315284
1014 933 345
1192 1097 1098 1099
1174
1303 1304 1100
11751305 1101
1176 1306134 1102
1177 1307 116
1103
1178 1142 100
281
3291237
1096 1172
1301
1326 1173
1302
1135 1136 1137
945 1138 1139 1140
318 1308
1179
1141 11431242
975 1134
1193 985 963 952 944 916 1019 1013316 1241
285
700701
932
717
716
829
1300
828
1299
602603
991 400
915 136 133697 115
698 699
826 827280
1298
601 99 346
317 1297
990 976 984
992
987 943
913 695 696
823
1294 824
1295
598
825
1012
1296
599 600
11451 286
622
1236
986 977 983 962 953 9421246
1040
989 694
853 822
1293
596 5971020
11350 1195
1211011 279
870 858
973
988 1091 1090 1095
11841288 867
1094
1185 912
145 155
1089 132
929
1087 1093
1180
1283 1092
1285
1181
1284
1126 1125 1286
1182 1183
1124 1287
1123 11281289 1186
1127
1199 1290
112211871088
1291
1121 1130
1188
1292
11321131
1189
1133
287
1239 328
1240
278
10391330
928 1120
974 978
972 982 961 954 941 161 146
162 1021 112 101048 685
661 686
848
1281
847
684
849
1282
869 1230619
1194
683
567
926 979 971 160 909154131122
157
940 111
667 662
1279
575
1009
1280
47
846 568 277
618 349
398159
156147 908 663 668
844
1277 8451200
1278
576 288
981 960 153
664 8431022
571 276 1235
930 927 925 980 970
1038 955 659
95 939
840
1273
1245 565
142
158
666
1274665
841
574 1275
573
907
1276
842 572 110 44 326
1008 350
924 878968
969
8791080 1081
1268
11671113 1083
11681269143 148
141
1086
1169 152
1085130
1023123 109 289
275
931
1037
873874
1323 875
1162
1262
1105
876
1163
1263
1106
877
923
1164
1264
1107 1266
1165
1265
1108
1111 1166
1109 1267
1110
922 1112
959 39794 1115 1270 1170
1117
1197 1271 1171
1116 1082
1272
1114
1033108
431250
1118
745
637656
290743 1249
1153 1234
1248
351
1104 956 92 149
938 140 42
639 1261
812
1260557
1007274
958
921 151129 124640
1259
564563
811322 325
396 91 150904 139 636 638
809 810
1258
561
1032 1198
1064 1324 918 96 93 937632 633635
807
7 808
138
1256
1375441257
545 1006
273 1233 352
395
97
628 629
803 630
957
917
3804
1252 1253 631
90
4634 5 1255
89806
1254
805 6 58128125106
903 39321
627 1251
1244
1 2 1191 902 127
57 105 324 1232 353
920 54 1031 38
901 126 37320 354
467 936 53 852 3231227
919
1065 900 56 36 355
103
55 356121226356
119089933
3631223
850 1225
898
32
1224 357
468 608 1217
1066 1213
362 610
1215
361 1214
1209
358
1206
469 1207
604 606
1205
1067 1202
1203
360 359
1201
1340
1339
1341
1336 470
Y
X Z
Load 101
1335

MEMBER NUMBER

Print Time/Date: 11/12/2018 17:11 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 3 of 5
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date11-Sep-18 Chd

Client File GOA POD- R16.std (FINALDate/Time


)-R1.std 11-Dec-2018 16:47

Y
X Z
Load 101 : Bending Z

BMD

Print Time/Date: 11/12/2018 17:11 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 4 of 5
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date11-Sep-18 Chd

Client File GOA POD- R16.std (FINALDate/Time


)-R1.std 11-Dec-2018 16:47

Y
X Z
Load 101 : Shear Y

SFD

Print Time/Date: 11/12/2018 17:11 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 5 of 5
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Sep-18 Chd

Client File GOA POD- R16.std (FINALDate/Time


)-R1.std 11-Dec-2018 18:04

0.000577
0.0748
0.106
0.0306
0.106
0.0242
0.137
0.159
0.112 0.175
0.197 0.05150.0684
0.222 0.0351 0.0385
0.106
0.24
0.258 0.1730.0383
0.0647
0.0286
0.106
0.137
0.029 0.000577
0.269
0.262 0.159
0.0247
0.0901
0.259
0.206 0.175
0.0222
0.0337 0.075
0.291 0.099 0.0202
0.197
0.0296 0.0302
0.0977
0.3220.163 0.264 0.01860.0244
0.0515
0.0428
0.204 0.125 0.222
0.0287 0.0194
0.112
0.0562
0.02480.0351
0.0383
0.288 0.24
0.145 0.0727 0.0227
0.0647
0.116 0.258 0.0563
0.173
0.0237
0.0719 0.0901
0.264 0.12 0.135 0.0894
0.0716 0.0337
0.0274
0.1320.171
0.273 0.134 0.269
0.263
0.162
0.0602
0.0787
0.317
0.0702
0.0296
0.0378
0.0428
0.0558
0.0775
0.111 0.194 0.291 0.324 0.206
0.2590.225
0.099 0.131
0.17 0.0562
0.264
0.0927
0.12
0.0624
0.128
0.173 0.112
0.137
0.0538 0.0349
0.155
0.0827 0.223
0.110.121 0.0866
0.232 0.209
0.0977
0.246
0.0937 0.2420.0727
0.0563
0.309
0.0719
0.0894
0.2740.187
0.0348 0.0718 0.0651
0.232 0.0837
0.127 0.131
0.128
0.08960.268
0.0940.0631 0.125
0.468
0.1630.3990.388
0.0716
0.0602
0.388
0.0787
0.0702
0.309
0.242
0.17
0.131
0.0775
0.112 0.0425 0.112 0.291
0.322 0.0821
0.145
0.144
0.419 0.128
0.317
0.0745
0.116
0.581
0.135
0.162
0.641
0.225
0.0821
0.641
0.468
0.246
0.581
0.219
0.16 0.0931 0.0515 0.1010.2170.104 0.0813 0.0631 0.399
0.268
0.134 0.0989
0.209
0.0996
0.176 0.28 0.394 0.204 0.0895 0.128
0.0671
0.0936
0.131
0.0854
0.145 0.132
0.143
0.0693 0.138
0.123 0.117
0.124
0.0294
0.1390.161 0.386
0.163
0.267 0.125 0.22
0.288
0.157 0.104 0.059
0.12
0.2320.145
0.0867 0.0749
0.2170.22
0.0815 0.135
0.318
0.08170.0907
0.123 0.119
0.063 0.122
0.132 0.119 0.128
0.134 0.309
0.184
0.179 0.169
0.264
0.075 0.121
0.194
0.223
0.121 0.118
0.0444 0.285 0.11
0.0836
0.111
0.0826 0.094
0.106 0.0446
0.0589
0.08830.06540.0928 0.141 0.171
0.0654 0.324
0.155 0.133
0.286
0.0678 0.0508
0.208
0.0848
0.172 0.087 0.0614 0.286 0.1
0.033 0.127 0.106
0.111
0.121
0.194
0.117
0.0746
0.241 0.1 0.108 0.1420.265 0.18
0.132
0.273
0.0722
0.0544 0.291
0.135 0.0813
0.169
0.0678
0.0561
0.109
0.058 0.227 0.232 0.163
0.165 0.247
0.159
0.218 0.124 0.359
0.174
0.131 0.0344
0.330.130.194
0.1120.232
0.14 0.184
0.1790.104 0.0905
0.141
0.235 0.148 0.149
0.165
0.0986
0.161
0.24 0.144
0.121 0.0689
0.21 0.219 0.165
0.21 0.187
0.301
0.233 0.173
0.312
0.187
0.12 0.484
0.228 0.129
0.309
0.104
0.22
0.075 0.0498
0.238 0.5
0.223 0.182
0.03240.242 0.0967
0.241 0.06 0.111
0.129
0.0625
0.177 0.484 0.253
0.157
0.241
0.128
0.204
0.112 0.194 0.129
0.264
0.116
0.1090.0542
0.0248 0.0444
0.166 0.302
0.1670.274 0.134
0.125
0.217
0.269
0.386 0.0596
0.136
0.18 0.1120.0608
0.0712 0.112
0.299 0.0424 0.163
0.119 0.265
0.0999
0.1340.192
0.136
0.192
0.264
0.269
0.116
0.0248 0.179 0.0596 0.156 0.32 0.122 0.179 0.162
0.157
0.101
0.394 0.194 0.0606
0.244
0.2970.0856 0.0231 0.0787
0.214
0.439
0.298
0.0644
0.369 0.386
0.139
0.124
0.0515
0.267 0.14
0.253
0.241
0.204 0.1110.0802
0.0261
0.217 0.216
0.216 0.352
0.209 0.203
0.18
0.13
0.3160.29 0.316
0.0822 0.220.319 0.356
0.233 0.119
0.138
0.0931
0.1230.2120.117
0.28 0.484
0.18
0.284
0.226 0.134
0.484 0.06
0.0418
0.259
0.3 0.125
0.17 0.22
0.178
0.294 0.311
0.31 0.357 0.347
0.337 0.132
0.292 0.21
0.3340.382
0.219
0.16
0.123 0.387
0.209
0.495
0.143
0.249 0.176
0.752 0.132 0.228
0.129
0.713 0.1450.3020.0975
0.127
0.745 0.183
0.941
0.451 0.253 0.171
0.309 0.0444 0.0693
0.135 0.388
0.3290.853
0.063
0.132 0.22 0.312
0.286 0.157
0.322
0.572
0.0741
0.416
0.667 0.318 0.09070.233 0.906
0.141 0.33
0.1870.177
0.265
0.26
0.161
0.226
0.439 0.22 0.0854
0.145
0.4 0.609
0.0817 0.21
0.13
0.142
0.35
0.301
0.359
0.174
0.323
0.572
0.907
0.285 0.247 0.0815
0.217 0.156
0.0614
0.124 0.179
0.161
0.179
0.853
0.713
0.302 0.105
0.442 0.219
0.676
0.09280.087 0.247
0.159 0.165
0.3290.197
0.1970.324
0.388
0.212
0.0883
0.208 0.0655 0.21
0.404 0.218
0.165
0.1630.167 0.299
0.752
0.22 0.4590.119
0.0848
0.509
0.241 0.144
0.108 0.248 0.387
0.32
0.209
0.172
0.117
0.07460.1 0.121
0.149 0.677
0.232 0.0601
0.0689 0.382 0.384
0.156
0.495
0.242
0.241 0.165
0.24
0.109 0.227 0.156
0.356
0.233
0.21 0.237 0.126
0.105 0.0542
0.5 0.058
0.1820.148
0.0986
0.161 0.0967
0.382
0.45 0.6450.319 0.609
0.223
0.141
0.235
0.0324 0.3470.0644
0.0596 0.386
0.22 0.3340.237
0.5170.6010.126
0.182 0.238
0.109 0.166
0.04440.357 0.316
0.509
0.37
0.203
0.0711 0.676
0.0248 0.337
0.179
0.18
0.439 0.4
0.132 0.677
0.02480.292
0.13
0.0231
0.3110.3160.214
0.0787
0.2980.0822
0.83 0.646
0.645 0.414 0.157
0.31 0.2090.3520.29
1.04
0.171 0.404
0.509
0.244
0.297
0.0856
0.253
0.1780.216 0.309
0.22
0.0261
0.2940.216 0.247
0.439 0.274
0.756 0.22
0.83
0.451
0.17
0.183 0.217 0.442
0.382
0.509
0.45 0.264
0.416
0.667 0.941
0.745 0.125 1.04 0.421
0.0418
0.259
0.07410.3
0.127 0.264
0.418 1.10.378
0.221
0.853
0.333
0.169
0.285 0.681
0.681
0.142
0.592
0.516
0.3480.0742
0.463
0.822 0.299
0.572
0.182 0.323
0.796
0.255

0.418

0.822
Y
X Z
Load 101 : Displacement

UR

Print Time/Date: 11/12/2018 18:14 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
STAAD OUTPUT
****************************************************
* *
* STAAD.Pro CONNECT Edition *
* Version 21.00.02.43 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= DEC 11, 2018 *
* Time= 13:28: 9 *
* *
* Licensed to: Roark Consulting EngineersNoid *
****************************************************

1. STAAD SPACE DXF IMPORT OF CENTERLINES GOA HAAT POD.DXF_FINAL.DXF


INPUT FILE: D:\E Drive Data\MOFA\GOA BAZAR\GOA POD\FINAL GOA POD\STAAD\GOA
POD- R16.std (FINAL ).STD
2. START JOB INFORMATION
3. ENGINEER DATE 11-SEP-18
4. END JOB INFORMATION
5. PAGE LENGTH 10000
6. SET ECHO OFF

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 496 NUMBER OF MEMBERS 798


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 4

Using 64-bit analysis engine.

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 466/ 41/ 252 DOF


TOTAL PRIMARY LOAD CASES = 8, TOTAL DEGREES OF FREEDOM =
2952
TOTAL LOAD COMBINATION CASES = 26 SO FAR.
SIZE OF STIFFNESS MATRIX = 744 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 21.6/ 148431.3 MB
*********************************************************
* UNITS - KN METE *
* TIME PERIOD FOR X 1893 LOADING = 0.55900 SEC *
* SA/G PER 1893= 2.433, LOAD FACTOR= 1.000 *
* VB PER 1893= 0.0487 X 885.17= 43.07 KN *
* *
*********************************************************

*********************************************************
* UNITS - KN METE *
* TIME PERIOD FOR Z 1893 LOADING = 0.61400 SEC *
* SA/G PER 1893= 2.215, LOAD FACTOR= 1.000 *
* VB PER 1893= 0.0443 X 885.17= 39.21 KN *
* *
*********************************************************

STEEL DESIGN

|------------------------------------------------------------------------
----------|
| Member Number: 1
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.120 Critical Load Case: 303 Location:
0.42 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 2
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.291 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 3
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.105 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 4
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.188 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 5
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.187 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 6
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.317 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 7
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.268 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 8
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.037 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 9
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.032 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 10
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 11
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.085 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 12
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.032 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 13
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.029 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 14
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.041 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 15
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.054 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 16
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.069 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 17
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.054 Critical Load Case: 303 Location:
0.10 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 18
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 19
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.068 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 20
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.076 Critical Load Case: 303 Location:
0.11 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 21
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.127 Critical Load Case: 303 Location:
0.15 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 22
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.165 Critical Load Case: 303 Location:
0.11 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 23
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 303 Location:
0.21 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 25
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.298 Critical Load Case: 303 Location:
0.20 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 27
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.386 Critical Load Case: 304 Location:
0.24 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 33
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.770 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 35
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.475 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 36
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.602 Critical Load Case: 303 Location:
0.84 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 37
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.633 Critical Load Case: 303 Location:
0.63 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 38
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.632 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 39
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.571 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 42
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.296 Critical Load Case: 303 Location:
0.75 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 43
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.285 Critical Load Case: 303 Location:
0.48 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 44
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.287 Critical Load Case: 303 Location:
0.68 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 47
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.251 Critical Load Case: 303 Location:
0.36 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 48
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.269 Critical Load Case: 303 Location:
0.62 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 50
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.268 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 51
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.250 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 53
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.429 Critical Load Case: 303 Location:
1.23 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 54
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.426 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 55
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.437 Critical Load Case: 303 Location:
1.49 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 56
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.493 Critical Load Case: 303 Location:
1.13 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 57
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.302 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 58
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.282 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 89
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.187 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 90
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.022 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 91
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.025 Critical Load Case: 303 Location:
0.91 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 92
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.025 Critical Load Case: 303 Location:
0.04 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 93
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.085 Critical Load Case: 303 Location:
1.61 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 94
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.108 Critical Load Case: 303 Location:
0.80 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 95
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 303 Location:
0.40 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 96
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.286 Critical Load Case: 303 Location:
1.62 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 97
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.040 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 99
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.063 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 100
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.054 Critical Load Case: 312 Location:
1.17 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 101
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 303 Location:
1.28 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 102
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.199 Critical Load Case: 304 Location:
0.33 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 103
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.359 Critical Load Case: 303 Location:
1.14 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 105
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.377 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 106
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.317 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 108
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.150 Critical Load Case: 303 Location:
0.94 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 109
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 303 Location:
0.69 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 110
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.157 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 111
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 303 Location:
0.70 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 112
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 113
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.124 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 114
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.109 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 115
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.097 Critical Load Case: 303 Location:
0.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 116
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.105 Critical Load Case: 303 Location:
1.02 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 117
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.105 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 118
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 303 Location:
1.70 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 119
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 303 Location:
1.04 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 120
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 121
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 122
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.061 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 123
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.058 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 124
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.061 Critical Load Case: 303 Location:
0.77 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 125
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.125 Critical Load Case: 303 Location:
1.51 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 126
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.233 Critical Load Case: 302 Location:
1.29 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 127
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 128
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.079 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 129
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.059 Critical Load Case: 304 Location:
1.32 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 130
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.071 Critical Load Case: 304 Location:
1.09 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 131
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.087 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 132
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.089 Critical Load Case: 304 Location:
1.13 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 133
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.091 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 134
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.112 Critical Load Case: 312 Location:
1.35 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 135
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 312 Location:
0.36 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 136
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 137
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.072 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 138
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.206 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 139
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.173 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 140
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 304 Location:
1.04 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 141
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.156 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 142
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 143
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.026 Critical Load Case: 302 Location:
0.62 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 145
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.079 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 146
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.064 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 147
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.100 Critical Load Case: 304 Location:
1.06 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 148
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.096 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 149
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.038 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 150
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.019 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 151
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.066 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 152
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.096 Critical Load Case: 304 Location:
1.14 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 153
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.109 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 154
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.093 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 155
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 304 Location:
0.90 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 156
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.108 Critical Load Case: 303 Location:
0.36 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 157
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.163 Critical Load Case: 303 Location:
0.52 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 158
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.058 Critical Load Case: 303 Location:
0.58 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 159
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.074 Critical Load Case: 303 Location:
0.29 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 160
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 303 Location:
0.59 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 161
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.086 Critical Load Case: 303 Location:
0.15 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 162
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.208 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 181
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.090 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 182
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.120 Critical Load Case: 304 Location:
0.75 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 183
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.140 Critical Load Case: 304 Location:
0.41 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 184
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 304 Location:
0.61 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 185
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 312 Location:
0.86 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 186
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.161 Critical Load Case: 303 Location:
0.46 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 187
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 303 Location:
0.34 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 188
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.243 Critical Load Case: 303 Location:
0.48 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 189
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.388 Critical Load Case: 303 Location:
0.61 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 190
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.556 Critical Load Case: 303 Location:
0.58 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 191
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.614 Critical Load Case: 303 Location:
0.28 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 270
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.092 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 271
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.182 Critical Load Case: 302 Location:
0.61 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 272
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 302 Location:
0.24 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 273
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 274
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.153 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 275
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 276
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.153 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 277
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.132 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 278
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.140 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 279
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.100 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 280
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.073 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 281
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 282
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.085 Critical Load Case: 302 Location:
0.89 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 283
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 302 Location:
1.87 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 284
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.120 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 285
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 304 Location:
1.23 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 286
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.130 Critical Load Case: 303 Location:
1.18 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 287
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.175 Critical Load Case: 303 Location:
1.25 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 288
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.175 Critical Load Case: 303 Location:
1.16 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 289
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.177 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 290
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.209 Critical Load Case: 304 Location:
0.49 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 313
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.301 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 314
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.242 Critical Load Case: 303 Location:
2.02 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 315
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.216 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 316
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.206 Critical Load Case: 303 Location:
1.18 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 317
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.052 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 318
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.041 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 319
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.055 Critical Load Case: 304 Location:
0.56 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 320
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 321
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.154 Critical Load Case: 304 Location:
0.89 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 322
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.216 Critical Load Case: 304 Location:
0.96 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 323
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.439 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 324
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.315 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 325
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.142 Critical Load Case: 304 Location:
1.77 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 326
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.121 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 328
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.041 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 329
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.040 Critical Load Case: 303 Location:
1.33 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 330
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.060 Critical Load Case: 304 Location:
0.95 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 332
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 303 Location:
2.05 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 333
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.151 Critical Load Case: 303 Location:
1.35 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 334
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.168 Critical Load Case: 303 Location:
3.45 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 343
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.128 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 344
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.099 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 345
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.076 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 346
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.042 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 349
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.042 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 350
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.058 Critical Load Case: 304 Location:
0.84 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 351
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.080 Critical Load Case: 304 Location:
1.15 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 352
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.103 Critical Load Case: 303 Location:
0.82 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 353
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 303 Location:
1.17 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 354
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.125 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 355
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.125 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 356
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.126 Critical Load Case: 302 Location:
1.31 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 357
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.199 Critical Load Case: 302 Location:
0.50 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 358
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.084 Critical Load Case: 302 Location:
1.45 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

AS PER SECTION 4.4.2 of IS800-2007. ALSO, ENSURE THAT THE TYPE OF


COMBINATION USED IS
REPEAT LOAD OR REFERENCE LOAD INSTEAD OF THE LOAD COMBINATION SYNTAX
EXCEPT FOR
RESPONSE SPECTRUM LOAD CASES.
|------------------------------------------------------------------------
----------|
| Member Number: 359
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.600 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 360
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.482 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 361
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.553 Critical Load Case: 304 Location:
0.87 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 362
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.723 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 363
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.679 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 395
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.265 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 396
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.250 Critical Load Case: 312 Location:
1.71 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 397
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 304 Location:
1.71 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 398
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.243 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 400
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 401
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.273 Critical Load Case: 304 Location:
1.74 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 402
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.275 Critical Load Case: 304 Location:
1.73 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 403
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.292 Critical Load Case: 312 Location:
1.76 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 404
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.295 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 405
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.257 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 406
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.221 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 407
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.195 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 408
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.174 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 409
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.158 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 410
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.136 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 411
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.106 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 412
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.293 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 413
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.247 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 414
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.088 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 415
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.053 Critical Load Case: 304 Location:
2.87 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 416
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.036 Critical Load Case: 304 Location:
3.39 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 417
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.026 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 418
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.023 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 419
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.022 Critical Load Case: 304 Location:
4.50 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 420
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.025 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 421
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.018 Critical Load Case: 304 Location:
5.08 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 422
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.018 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 423
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.267 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 424
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.257 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 425
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 437
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.020 Critical Load Case: 306 Location:
5.59 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 438
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.022 Critical Load Case: 307 Location:
5.81 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 453
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.046 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 454
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.023 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 455
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.029 Critical Load Case: 303 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 456
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.074 Critical Load Case: 301 Location:
0.73 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 457
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.105 Critical Load Case: 304 Location:
2.40 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 458
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.024 Critical Load Case: 307 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 459
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.028 Critical Load Case: 307 Location:
6.20 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 460
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.028 Critical Load Case: 307 Location:
6.37 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 461
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.037 Critical Load Case: 307 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 465
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.112 Critical Load Case: 303 Location:
4.19 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 467
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.297 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 468
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.184 Critical Load Case: 312 Location:
4.02 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 469
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.419 Critical Load Case: 304 Location:
3.51 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 470
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.828 Critical Load Case: 304 Location:
4.91 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 489
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.001 Critical Load Case: 307 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 512
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 513
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.066 Critical Load Case: 303 Location:
0.22 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 514
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.070 Critical Load Case: 303 Location:
0.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 516
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.086 Critical Load Case: 303 Location:
0.12 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 537
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.072 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 538
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.203 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 539
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.322 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 540
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.285 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 541
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.186 Critical Load Case: 304 Location:
1.26 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 542
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.121 Critical Load Case: 304 Location:
1.23 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 544
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.414 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 545
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.340 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 557
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.690 Critical Load Case: 302 Location:
1.76 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 561
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.355 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 563
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.361 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 564
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.332 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 565
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.229 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 567
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.459 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 568
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.331 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 571
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.151 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 572
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 573
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.221 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 574
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.148 Critical Load Case: 311 Location:
1.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 575
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.345 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 576
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 596
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.145 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 597
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 598
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 304 Location:
1.26 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 599
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.257 Critical Load Case: 304 Location:
1.30 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 600
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.377 Critical Load Case: 304 Location:
1.36 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 601
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.382 Critical Load Case: 304 Location:
1.43 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 602
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.204 Critical Load Case: 302 Location:
1.53 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 603
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.093 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 604
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.347 Critical Load Case: 304 Location:
0.86 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 606
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.263 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 608
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.975 Critical Load Case: 304 Location:
1.75 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 610
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.156 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 612
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.556 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 618
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.090 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 619
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.043 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 622
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.040 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 627
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.657 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 628
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.408 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 629
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.464 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 630
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.269 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 631
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.324 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 632
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.297 Critical Load Case: 304 Location:
0.94 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 633
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.340 Critical Load Case: 302 Location:
0.26 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 634
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.323 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 635
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.360 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 636
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.355 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 637
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.733 Critical Load Case: 302 Location:
0.88 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 638
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.212 Critical Load Case: 302 Location:
1.41 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 639
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.297 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 640
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.250 Critical Load Case: 302 Location:
1.51 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 656
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.560 Critical Load Case: 311 Location:
0.70 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 659
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.053 Critical Load Case: 304 Location:
1.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 661
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 662
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.130 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 663
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.216 Critical Load Case: 302 Location:
1.29 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 664
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.206 Critical Load Case: 302 Location:
0.84 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 665
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.237 Critical Load Case: 304 Location:
1.23 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 666
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.237 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 667
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 302 Location:
1.42 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 668
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.204 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 683
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 302 Location:
0.96 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 684
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.259 Critical Load Case: 302 Location:
0.98 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 685
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.251 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 686
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.125 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 694
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.045 Critical Load Case: 304 Location:
1.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 695
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.123 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 696
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 304 Location:
0.31 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 697
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 302 Location:
0.43 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 698
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.116 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 699
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.122 Critical Load Case: 302 Location:
1.43 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 700
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.172 Critical Load Case: 302 Location:
1.53 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 701
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 716
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.178 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 717
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.099 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 720
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.071 Critical Load Case: 303 Location:
0.81 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 721
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.101 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 722
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.094 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 723
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.071 Critical Load Case: 304 Location:
0.97 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 724
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.077 Critical Load Case: 304 Location:
0.75 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 725
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.034 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 726
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.448 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 743
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.287 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 745
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.324 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 747
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 750
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.117 Critical Load Case: 301 Location:
1.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 751
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.151 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 753
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.137 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 755
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.119 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 758
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.092 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 759
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.055 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 760
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 303 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 803
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.941 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 804
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.170 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 805
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.176 Critical Load Case: 303 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 806
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.202 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 807
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.132 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 808
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.207 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 809
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.218 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 810
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 811
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 812
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.368 Critical Load Case: 302 Location:
1.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 822
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 823
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.143 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 824
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.136 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 825
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.139 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 826
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.158 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 827
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 828
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.185 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 829
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.116 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 840
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.179 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 841
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.164 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 842
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.123 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 843
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.164 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 844
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 845
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.172 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 846
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.181 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 847
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.215 Critical Load Case: 302 Location:
1.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 848
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.239 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 849
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.113 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 850
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.932 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 852
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.381 Critical Load Case: 303 Location:
1.40 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 853
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.083 Critical Load Case: 303 Location:
0.36 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 858
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.035 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 864
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.068 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 867
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 304 Location:
1.70 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 868
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.067 Critical Load Case: 303 Location:
1.01 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 869
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.196 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 870
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.123 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 873
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.120 Critical Load Case: 304 Location:
0.42 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 874
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.291 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 875
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.105 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 876
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.188 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 877
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.187 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 878
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.317 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 879
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.268 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 880
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.037 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 881
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.032 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 882
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 883
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.085 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 884
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.032 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 885
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.029 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 886
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.041 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 887
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.054 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 888
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.069 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 889
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.054 Critical Load Case: 304 Location:
0.10 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 890
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 891
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.068 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 892
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.076 Critical Load Case: 304 Location:
0.11 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 893
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.127 Critical Load Case: 304 Location:
0.15 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 894
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.165 Critical Load Case: 304 Location:
0.11 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 895
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 304 Location:
0.21 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 896
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.299 Critical Load Case: 304 Location:
0.20 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 897
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.386 Critical Load Case: 303 Location:
0.24 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 899
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.770 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 900
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.475 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 901
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.601 Critical Load Case: 304 Location:
0.84 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 902
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.633 Critical Load Case: 304 Location:
0.63 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 903
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.632 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 904
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.571 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 907
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.296 Critical Load Case: 304 Location:
0.75 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 908
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.285 Critical Load Case: 304 Location:
0.48 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 909
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.287 Critical Load Case: 304 Location:
0.68 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 912
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.251 Critical Load Case: 304 Location:
0.36 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 913
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.269 Critical Load Case: 304 Location:
0.62 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 915
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.268 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 916
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.250 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 917
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.429 Critical Load Case: 304 Location:
1.23 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 918
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.426 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 919
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.437 Critical Load Case: 304 Location:
1.49 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 920
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.494 Critical Load Case: 304 Location:
1.13 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 921
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.302 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 922
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.282 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 923
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.187 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 924
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.022 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 925
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.025 Critical Load Case: 304 Location:
0.91 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 926
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.025 Critical Load Case: 304 Location:
0.04 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 927
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.085 Critical Load Case: 304 Location:
1.61 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 928
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.108 Critical Load Case: 304 Location:
0.80 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 929
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 304 Location:
0.40 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 930
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.286 Critical Load Case: 304 Location:
1.62 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 931
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.040 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 932
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.063 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 933
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.054 Critical Load Case: 311 Location:
1.17 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 934
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 304 Location:
1.28 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 935
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.199 Critical Load Case: 303 Location:
0.33 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 936
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.360 Critical Load Case: 304 Location:
1.14 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 937
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.377 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 938
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.317 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 939
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.150 Critical Load Case: 304 Location:
0.94 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 940
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 304 Location:
0.69 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 941
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.157 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 942
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 304 Location:
0.70 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 943
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 944
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.124 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 945
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.109 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 946
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.097 Critical Load Case: 304 Location:
0.14 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 947
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 304 Location:
1.02 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 948
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 949
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 304 Location:
1.70 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 950
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 304 Location:
1.04 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 951
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 952
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 953
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.061 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 954
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.058 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 955
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.061 Critical Load Case: 304 Location:
0.77 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 956
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.125 Critical Load Case: 304 Location:
1.51 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 957
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.232 Critical Load Case: 302 Location:
1.29 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 958
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 959
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.079 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 960
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.059 Critical Load Case: 303 Location:
1.32 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 961
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.071 Critical Load Case: 303 Location:
1.09 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 962
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.087 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 963
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.089 Critical Load Case: 303 Location:
1.13 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 964
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.091 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 965
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.112 Critical Load Case: 311 Location:
1.35 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 966
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 311 Location:
0.36 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 967
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 968
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.072 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 969
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.206 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 970
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.173 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 971
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 303 Location:
1.04 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 972
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.156 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 973
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 974
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.026 Critical Load Case: 302 Location:
0.62 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 975
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.079 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 976
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.064 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 977
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.100 Critical Load Case: 303 Location:
1.06 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 978
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.096 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 979
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.038 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 980
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.019 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 981
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.066 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 982
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.096 Critical Load Case: 303 Location:
1.14 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 983
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.109 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 984
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.093 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 985
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 303 Location:
0.90 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 986
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.108 Critical Load Case: 304 Location:
0.36 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 987
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.163 Critical Load Case: 304 Location:
0.52 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 988
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.058 Critical Load Case: 304 Location:
0.58 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 989
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.074 Critical Load Case: 304 Location:
0.29 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 990
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 304 Location:
0.59 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 991
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.086 Critical Load Case: 304 Location:
0.15 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 992
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.208 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 993
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.090 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 994
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.120 Critical Load Case: 303 Location:
0.75 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 995
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.140 Critical Load Case: 303 Location:
0.41 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 996
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 303 Location:
0.61 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 997
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 311 Location:
0.86 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 998
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.161 Critical Load Case: 304 Location:
0.46 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 999
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 304 Location:
0.34 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1000
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.243 Critical Load Case: 304 Location:
0.48 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1001
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.388 Critical Load Case: 304 Location:
0.61 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1002
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.556 Critical Load Case: 304 Location:
0.58 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1003
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.092 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.4
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1004
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.182 Critical Load Case: 302 Location:
0.61 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1005
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 302 Location:
0.24 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1006
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1007
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.153 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1008
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1009
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.153 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1010
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.132 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1011
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.140 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1012
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.100 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1013
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.073 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1014
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.082 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1015
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.085 Critical Load Case: 302 Location:
0.89 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1016
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 302 Location:
1.87 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1017
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.120 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1018
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 303 Location:
1.23 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1019
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.130 Critical Load Case: 304 Location:
1.18 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1020
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.175 Critical Load Case: 304 Location:
1.25 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1021
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.175 Critical Load Case: 304 Location:
1.16 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1022
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.177 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1023
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.208 Critical Load Case: 303 Location:
0.49 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1024
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.301 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1025
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.242 Critical Load Case: 304 Location:
2.02 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1026
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.216 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1027
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.206 Critical Load Case: 304 Location:
1.18 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1028
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.052 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1029
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.041 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1030
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.055 Critical Load Case: 303 Location:
0.56 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1031
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1032
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.154 Critical Load Case: 303 Location:
0.89 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1033
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.215 Critical Load Case: 303 Location:
0.96 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1034
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 304 Location:
2.05 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1035
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.151 Critical Load Case: 304 Location:
1.35 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1036
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.168 Critical Load Case: 304 Location:
3.45 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1037
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.265 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1038
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.250 Critical Load Case: 311 Location:
1.71 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1039
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 303 Location:
1.71 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1040
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.243 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1041
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1042
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.273 Critical Load Case: 303 Location:
1.74 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1043
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.275 Critical Load Case: 303 Location:
1.73 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1044
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.292 Critical Load Case: 311 Location:
1.76 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1045
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.295 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1046
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.257 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1047
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.221 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1048
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.195 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1049
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.174 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1050
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.158 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1051
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.136 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1052
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.106 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1053
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.293 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1054
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.247 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1055
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.267 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1056
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.257 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1057
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1058
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.046 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1059
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.023 Critical Load Case: 304 Location:
0.44 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1060
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.030 Critical Load Case: 304 Location:
0.45 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1061
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.074 Critical Load Case: 301 Location:
0.72 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1062
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.105 Critical Load Case: 303 Location:
2.40 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1063
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.112 Critical Load Case: 304 Location:
4.19 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1064
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.297 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1065
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.184 Critical Load Case: 311 Location:
4.02 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1066
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.419 Critical Load Case: 303 Location:
3.51 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1067
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.828 Critical Load Case: 303 Location:
4.91 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1069
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.001 Critical Load Case: 306 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1070
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1071
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.066 Critical Load Case: 304 Location:
0.22 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1072
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.070 Critical Load Case: 304 Location:
0.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1073
|
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.086 Critical Load Case: 304 Location:
0.12 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1074
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.072 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1075
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.203 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1076
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.322 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1077
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.285 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1078
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.186 Critical Load Case: 303 Location:
1.26 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1079
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.121 Critical Load Case: 303 Location:
1.23 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1080
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.414 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1081
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.340 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1082
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.690 Critical Load Case: 302 Location:
1.76 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1083
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.355 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1085
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.361 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1086
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.332 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1087
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.229 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1088
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.459 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1089
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.331 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1090
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.151 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1091
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1092
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.221 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1093
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.148 Critical Load Case: 312 Location:
1.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1094
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.345 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1095
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1096
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.145 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1097
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.135 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1098
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 303 Location:
1.26 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1099
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.257 Critical Load Case: 303 Location:
1.30 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1100
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.377 Critical Load Case: 303 Location:
1.36 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1101
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.382 Critical Load Case: 303 Location:
1.43 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1102
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.204 Critical Load Case: 302 Location:
1.53 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1103
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.093 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1104
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.657 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1105
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.408 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1106
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.464 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1107
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.269 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1108
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.324 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1109
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.297 Critical Load Case: 303 Location:
0.94 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1110
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.340 Critical Load Case: 302 Location:
0.26 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1111
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.323 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1112
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.360 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1113
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.355 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1114
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.732 Critical Load Case: 302 Location:
0.88 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1115
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.212 Critical Load Case: 302 Location:
1.41 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1116
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.297 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1117
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.250 Critical Load Case: 302 Location:
1.51 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1118
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.560 Critical Load Case: 312 Location:
0.70 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1120
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.053 Critical Load Case: 303 Location:
1.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1121
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1122
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.130 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1123
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.216 Critical Load Case: 302 Location:
1.29 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1124
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.206 Critical Load Case: 302 Location:
0.84 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1125
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.237 Critical Load Case: 303 Location:
1.23 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1126
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.237 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1127
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.226 Critical Load Case: 302 Location:
1.42 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1128
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.204 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1130
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 302 Location:
0.96 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1131
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.259 Critical Load Case: 302 Location:
0.98 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1132
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.251 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1133
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.125 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1134
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.045 Critical Load Case: 303 Location:
1.21 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1135
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.123 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1136
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 303 Location:
0.31 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1137
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 302 Location:
0.43 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1138
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.116 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1139
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.122 Critical Load Case: 302 Location:
1.43 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1140
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.172 Critical Load Case: 302 Location:
1.53 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1141
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1142
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.178 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1143
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.099 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1145
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.071 Critical Load Case: 304 Location:
0.81 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1146
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.101 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1147
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.094 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1148
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.070 Critical Load Case: 303 Location:
0.88 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1149
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.076 Critical Load Case: 303 Location:
0.74 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1150
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.034 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1151
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.448 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1153
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.287 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1154
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1155
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.117 Critical Load Case: 301 Location:
1.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1156
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.151 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1157
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.138 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1158
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1159
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.092 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1160
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.055 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1161
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 304 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1162
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.941 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1163
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.170 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1164
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.176 Critical Load Case: 304 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1165
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.202 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1166
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.132 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1167
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.207 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1168
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.218 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1169
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1170
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1171
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.368 Critical Load Case: 302 Location:
1.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1172
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.133 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1173
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.143 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1174
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.136 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1175
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.138 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1176
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.158 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1177
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.159 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1178
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.185 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1179
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.116 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1180
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.179 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1181
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.164 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1182
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.123 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1183
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.164 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1184
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1185
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.172 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1186
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.181 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1187
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.215 Critical Load Case: 302 Location:
1.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1188
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.239 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 8.2.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1189
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.113 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1190
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.932 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.1.1
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1191
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.381 Critical Load Case: 304 Location:
1.40 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1192
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.083 Critical Load Case: 304 Location:
0.36 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1193
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.219 Critical Load Case: 303 Location:
1.70 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1194
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.196 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1195
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.123 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1196
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.614 Critical Load Case: 304 Location:
0.28 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1197
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.462 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1198
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.462 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1199
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.286 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1200
|
| Member Section: ST 300X150X8.0RHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.286 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1201
|
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.941 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.1.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1202
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.332 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1203
|
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.717 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1205
|
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.519 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.1.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1206
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.464 Critical Load Case: 304 Location:
0.99 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1207
|
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.602 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1209
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.787 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1213
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.554 Critical Load Case: 302 Location:
0.16 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1214
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.104 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1215
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.500 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1217
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.199 Critical Load Case: 302 Location:
1.00 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1223
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.074 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1224
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.193 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1225
|
| Member Section: ST TUB E (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.169 Critical Load Case: 302 Location:
0.81 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1226
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.259 Critical Load Case: 302 Location:
0.15 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1227
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.374 Critical Load Case: 302 Location:
0.30 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1230
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.080 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1232
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.306 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1233
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.222 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1234
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.205 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1235
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.052 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1236
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.062 Critical Load Case: 302 Location:
0.23 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1237
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.086 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1238
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.072 Critical Load Case: 302 Location:
0.08 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1239
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.251 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1240
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.182 Critical Load Case: 304 Location:
0.38 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1241
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.272 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1242
|
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.131 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1243
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.370 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1244
|
| Member Section: ST 250X250X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.069 Critical Load Case: 312 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1245
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.221 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1246
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.218 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1247
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.190 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1250
|
| Member Section: ST 180X180X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.238 Critical Load Case: 302 Location:
1.66 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1251
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.786 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1252
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.191 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1253
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.299 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1254
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.211 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1255
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.300 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1256
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.188 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1257
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.317 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1258
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.332 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1259
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.372 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1260
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.696 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1261
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.804 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1262
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.786 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1263
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.191 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1264
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.299 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1265
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.211 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1266
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.300 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1267
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.188 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1268
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.317 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1269
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.332 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1270
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.372 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1271
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.696 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1272
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.804 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1273
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.492 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1274
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1275
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.150 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1276
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.143 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1277
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.215 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1278
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.124 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1279
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.134 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1280
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.287 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1281
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.457 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1282
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.189 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1283
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.492 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1284
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.234 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1285
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.150 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1286
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.143 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1287
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.215 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1288
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.124 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1289
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.134 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1290
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.287 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1291
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.457 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1292
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.189 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1293
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.319 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1294
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.068 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1295
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1296
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.119 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1297
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.157 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1298
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.116 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1299
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.296 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1300
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1301
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.319 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1302
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.068 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1303
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.118 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1304
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.119 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1305
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.157 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1306
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.116 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1307
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.296 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1308
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.162 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1309
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.187 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1310
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.061 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1311
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.045 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1312
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.073 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1313
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.117 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1314
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1315
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.232 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1316
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.187 Critical Load Case: 303 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1317
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.060 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1318
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.047 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1319
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.073 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1320
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.117 Critical Load Case: 302 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1321
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.114 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 6.3
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1322
|
| Member Section: ST 60X60X4.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.232 Critical Load Case: 304 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1323
|
| Member Section: ST 250X250X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.069 Critical Load Case: 311 Location:
0.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1324
|
| Member Section: ST 250X250X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.103 Critical Load Case: 302 Location:
6.08 |
| Critical Condition: Sec. 8.2.1.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1326
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.218 Critical Load Case: 303 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1328
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.190 Critical Load Case: 303 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1330
|
| Member Section: ST ISMB150 (INDIAN SECTIONS)
|
| Status: PASS Ratio: 0.221 Critical Load Case: 303 Location:
1.00 |
| Critical Condition: Sec. 9.3.2.2
|
|------------------------------------------------------------------------
----------|

|------------------------------------------------------------------------
----------|
| Member Number: 1333
|
| Member Section: ST 250X250X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.028 Critical Load Case: 312 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|
|------------------------------------------------------------------------
----------|
| Member Number: 1334
|
| Member Section: ST 250X250X8.0SHS (TATA STRUCTURA SECTIONS)
|
| Status: PASS Ratio: 0.023 Critical Load Case: 301 Location:
0.00 |
| Critical Condition: Sec. 7.1.2
|
|------------------------------------------------------------------------
----------|
DXF IMPORT OF CENTERLINES GOA HAAT POD.DXF_FINAL.DXF -- PAGE NO.

************ END OF DATA FROM INTERNAL STORAGE ************

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= DEC 11,2018 TIME= 13:28:19 ****

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://www.bentley.com/en/support/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2017 Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************
FOUNDATION DESIGN
z

p5 p6

p3
p4 x

p1 p2
z

p7 p8

p5 p6

x
p3 p4

p1 p2
ANCHOR BOLT & BASE PLATE
DESIGN
CALCULATION SHEET
PROJECT NAME GOA HAAT SHEET NO: 1

CALCULATION BY:- ROARK CONSULTING ENGINEERS LLP CHECKED BY:

DRAWING NO. Member Marked:

BASE PLATE DESIGN

DESIGN FORCES
Axial Force (F x) = 4677 KN
Shear Force (F y) = 369 KN
Shear Force (F Z) = 0 KN

COLUMN DETAILS
Section SHS 450X450X25
Grade of Steel = E250
Width (B) = 450 mm
Depth (D) = 650 mm
Thickness (t) = 25 mm
Ultimte tensile stress (fu) = 410 N/mm 2
2
Yield stress (fy) = 250 N/mm

ANCHOR BOLT DETAILS


Grade of Bolt = 8.8
Dia of Bolt = 39 mm
Dia of Hole = 42 mm
2
Asb = 1194 mm
2
Anb = 976 mm
2
Ultimte tensile stress (fub) = 830 N/mm
2
Yield stress (fy) = 660 N/mm
2
Proof Stress of Bole (fo) = 581 N/mm
Partial Saftey Factor (Y mb) = 1.25
Partial Saftey Factor (Y mo) = 1.1

WELD DETAILS
Weld Designation = Type E44
Weld Type = Shop weld
Weld thickness (tw) = 8 mm
2
Ultimte tensile stress (fuw) = 410 N/mm
Partial Saftey Factor (Y mb) = 1.5
Allowable Stress for weld = (fuw/ 3xYmw)
= 157.81 N/mm 2

CONCRETE PROPERTIES
Strength of Concrete = M25
Bearing Strength of Concrete = 0.6xfck
= 15 N/mm 2

BASE PLATE DETAILS


Grade of Steel = E250
Width of Plate = 750 mm
Depth of Plate = 940 mm
Thickness of Plate = 60 mm
Ultimte tensile stress (fup) = 410 N/mm 2
2
Yield stress (fy) = 250 N/mm
Partial Safety Factor (y mo) = 1.1
Allowable Shear stress = (0.58xfy/ymo)
= 131.82 N/mm 2
Allowable Tensile stress = (fy/ymo)
= 227.27 N/mm 2

SAFETY CHECKS FOR CONNECTIONS


SHEAR CAPACITY OF ANCHOR BOLT
Nominal Shear Capacity of Bolt (V nsb) = (fu/ 3)x(nnxAnb+ns xAsb)
No of Shear plane with threads (n n) = 1
No of Shear plane without threads (n s ) = 0
Vnsb = 467.7 KN
Design Shear Capacity of Bolt (V dsb) = Vnsb/Ymb
= 374.16 KN
BEARING CAPACITY OF ANCHOR BOLT
Nominal Bearing Capacity of Bolts (V npb) = 2.5xfuxkbxdxt
Where Kb = Min [(e/3d h),((p/3dh)-0.25),(fub/fu),1]
edge distance (e) = 75 mm
pitch (p) = 150 mm
Dia of Bolt Hole (d h) = 42 mm
e/3dh = 0.596
(p/3dh)-0.25 = 0.941
fub/fu = 2.025
Kb = 0.6
Vnpb = 1439.1 KN

TENSION CAPACITY OF ANCHOR BOLT


Nominal tension capacity of bolt (T nb) = (0.9xfubxAn)<(Asbxfybxymb/ymo)
= 729.08 KN < 895.5 KN Hence Safe
Tnb = 729.08 KN
Design Tension capacity of Bolt (T db) = Tnb/ymb
Tdb = 583.264 KN

CHECK FOR TENSION IN ANCHOR BOLT


Tension Force = 4677 KN
No of Bolts in Tension = 10
Tension Force per Bolt (T b) = 467.7 KN < 583.26 KN Hence Safe

CHECK FOR SHEAR IN THE BOLTS


Total No of Bolt = 10
Shear Force (F y) = (Fx2+Fy2) KN
= 369 KN
Shear Force per Bolt (V sb) = 36.90 KN < 374.16 KN Hence Safe

CHECK FOR COMBINED SHEAR & TENSION


[(Vsb/Vdsb)2+(Tb/Tdb)2]<1 = 0.653 < 1 Hence Safe

LENGTH OF ANCHOR BOLT


Na = k (fck)L1.5
k = 15.5 (for post installation k=13.5 & for cast insitu k=15.5)
Required Length of Anchor Bolt (L) = 331.47 mm

SIZE OF BASE PLATE


Pressure on Concrete Base (q) = Fx/(BxD) < 0.6 (Fck)
= 6.634 N/mm 2 < 15 N/mm 2 Hence Safe

BASEPLATE THICKNESS
Tension Force Per Bolt = 467.7 KN
edge disctance = 75 mm
Distance of Bolt from side Stiffner (b 1) = 75 mm
Distance of Bolt from bottom Stiffner (b 2) = 75 mm
Moment (M p) = 35.08 KNm
Dia of Bolt (d) = 39 mm
effective width for top flange (b e1) = (0.577xb1x2+d)
= 125.55 mm
effective width for stiffner side (b e2) = (0.577xb2x2+d)
= 125.55 mm
Total Effective Width for Plate (b e) = be1+be2
be = 251.1 mm
Thickness of End Plate (t) = [(4.4xMp)/(fyxbe)]
= 49.59 mm < 60 mm Hence Safe

CHECK FOR WELDING


Tension Force = 4677 KN
Shear Force = 369 KN
Length of Weld Available = 2200 mm
Weld Strength per mm = ttxFuw/ 3xymw
= 0.884 KN/mm
Weld Capacity = 1944.22 KN Stiffner Required
Provide 150 mm Stiffners in all four sides of column.
Length of Stiffner = 150
No of Stiffners = 16
Total Length Available for Welding = 7000 mm
Capacity of Weld = 6186 KN > 4677 KN Hence Safe
DRAWINGS
G O A H A A T ,M E R CES ,
THIS DRAWING IS THE PROPERTY OF G OA G EN E R A L A R R A N GE ME N T
KNOWLEDGE
''ROARK CONSULTING ENGINEERS'' ANY
QUALITY O F PO D
DUPLICATION IN PART OR WHOLE WILL
INNOVATION
CONSTITUTE AS ''A COPYRIGHT VOILATION''

- G H -S -0 1 R0

G1 . DO NOT SCALE THE DRAWING, FOL LOW ONL Y FIGURED


DIME NSIONS.
G2 . AL L DIMENSIO NS G IV EN IN THIS DRAWING ARE IN
MILLIMETERS.
G3 . AL L STRUCTURAL DRAWINGS SHO UL D BE RE AD IN
CONJUNCTION WITH RELE VANT A RCHITECTURAL
DRAWINGS. ANY DIS CRE PANCY OR AMBIGUITY IN EITHER
SHO UL D B E BROUGHT TO THE NOTICE OF THE CONS UL TANT
OR THE ARCHITECT.
G4 . UNO STANDS FOR UNL ESS NO TE D O THE RWISE .