Sei sulla pagina 1di 3

BEER LINE RESTRICTION REFERENCE GUIDE

RESISTANCE FACTORS TO CONSIDER:


• BEER LINE / TRUNKLINE • LIFT (OR) DROP
GEN-X™ Barrier Tubing Add or subtract (0.5 per ft)

• DRAFT EQUIPMENT HARDWARE • MINIMUM CHOKER AT DISPENSE HEAD


Jumper Line / Coupler / Draft Tower, etc. Kool-Rite™ Tower (7.5 – 10 lbs)

TYPE RESTRICTION LIQUID CONTENT LENGTH RESTRICTION


(SIZE) (lbs / ft) (oz / ft) (ft) (lbs)
VINYL
(I.D.)
3
⁄16" 3.00 1
⁄6 1 3.0
1
⁄4" 0.85 1
⁄3 3' 6" 2.9
5
⁄16" 0.40 1
⁄2 8 3.2
3
⁄8" 0.20 3
⁄4 15 3.0
1
⁄2" 0.025 1 ⁄3 1
120 3.0

STAINLESS STEEL
(I.D.) (O.D.)
3
⁄16" 1
⁄4" 1.20 1
⁄6 3 3.6
1
⁄4" 5
⁄16" 0.30 1
⁄3 10 3.0
5
⁄16" 3
⁄8" 0.12 1
⁄2 25 3.0

POLYETHYLENE
(I.D.)
⁄16"
3
2.20 1
⁄6 1' 3" 2.9
1
⁄4" 0.50 1
⁄3 6 3.0
⁄16"
5
0.20 1
⁄2 15 3.0
3
⁄8" 0.07 3
⁄4 45 3.0

GEN-X™ BARRIER TUBE


(I.D.)
1
⁄4" 0.30 1
⁄3 10 3.0
⁄16"
5
0.10 1
⁄2 30 3.0
3
⁄8" 0.06 3
⁄4 50 3.0

DRAFT EQUIPMENT HARDWARE ADD


5' JUMPER LINE
1.00 lbs
& "D" STYLE COUPLERS

SYST EM B A LA N C E / 6 1
SYSTEM WORKSHEET
BALANCE

CALCULATION VARIABLES

TOTAL SYSTEM
BEER LINE RESTRICTION LENGTH OF LINE (lbs) LIFT / DROP SYSTEM TARGET SUBTRACT RESTRICTION REQUIRED IN 3/16"
RESTRICTION
(SIZE I.D.) (lbs / ft) RUN (ft) RESTRICTION (.5 Lbs / ft ) HARDWARE PRESSURE TSR (3 lbs PER ft) CHOKER
(TSR)
1
⁄4" = 0.30 x = ± = + = - = ÷ 3 lbs =

⁄16" =
5
0.10 x = ± = + = - = ÷ 3 lbs =
3
⁄8" = 0.06 x = ± = + = - = ÷ 3 lbs =

NOTE: If Total System Restriction is higher than Target Pressure, use next size Beer Line I.D.

TOTAL SYSTEM
BEER LINE RESTRICTION LENGTH OF LINE (lbs) LIFT / DROP SYSTEM TARGET SUBTRACT RESTRICTION REQUIRED IN 3/16"
RESTRICTION
(SIZE I.D.) (lbs / ft) RUN (ft) RESTRICTION (.5 Lbs / ft ) HARDWARE PRESSURE TSR (3 lbs PER ft) CHOKER
(TSR)
1
⁄4" = 0.30 x = ± = + = - = ÷ 3 lbs =

⁄16" =
5
0.10 x = ± = + = - = ÷ 3 lbs =
3
⁄8" = 0.06 x = ± = + = - = ÷ 3 lbs =

NOTE: If Total System Restriction is higher than Target Pressure, use next size Beer Line I.D.

TOTAL SYSTEM
BEER LINE RESTRICTION LENGTH OF LINE (lbs) LIFT / DROP SYSTEM TARGET SUBTRACT RESTRICTION REQUIRED IN 3/16"
RESTRICTION
(SIZE I.D.) (lbs / ft) RUN (ft) RESTRICTION (.5 Lbs / ft ) HARDWARE PRESSURE TSR (3 lbs PER ft) CHOKER
(TSR)
1
⁄4" = 0.30 x = ± = + = - = ÷ 3 lbs =

⁄16" =
5
0.10 x = ± = + = - = ÷ 3 lbs =
3
⁄8" = 0.06 x = ± = + = - = ÷ 3 lbs =

NOTE: If Total System Restriction is higher than Target Pressure, use next size Beer Line I.D.

62 / SY S T E M B A L A N C E
CALCULATION VARIABLES

TOTAL SYSTEM
BEER LINE RESTRICTION LENGTH OF LINE (lbs) LIFT / DROP SYSTEM TARGET SUBTRACT RESTRICTION REQUIRED IN 3/16"
RESTRICTION
(SIZE I.D.) (lbs / ft) RUN (ft) RESTRICTION (.5 Lbs / ft ) HARDWARE PRESSURE TSR (3 lbs PER ft) CHOKER
(TSR)
1
⁄4" = 0.30 x = ± = + = - = ÷ 3 lbs =
5
⁄16" = 0.10 x = ± = + = - = ÷ 3 lbs =
3
⁄8" = 0.06 x = ± = + = - = ÷ 3 lbs =

NOTE: If Total System Restriction is higher than Target Pressure, use next size Beer Line I.D.

TOTAL SYSTEM
BEER LINE RESTRICTION LENGTH OF LINE (lbs) LIFT / DROP SYSTEM TARGET SUBTRACT RESTRICTION REQUIRED IN 3/16"
RESTRICTION
(SIZE I.D.) (lbs / ft) RUN (ft) RESTRICTION (.5 Lbs / ft ) HARDWARE PRESSURE TSR (3 lbs PER ft) CHOKER
(TSR)
1
⁄4" = 0.30 x = ± = + = - = ÷ 3 lbs =
5
⁄16" = 0.10 x = ± = + = - = ÷ 3 lbs =
3
⁄8" = 0.06 x = ± = + = - = ÷ 3 lbs =

NOTE: If Total System Restriction is higher than Target Pressure, use next size Beer Line I.D.

TOTAL SYSTEM
BEER LINE RESTRICTION LENGTH OF LINE (lbs) LIFT / DROP SYSTEM TARGET SUBTRACT RESTRICTION REQUIRED IN 3/16"
RESTRICTION
(SIZE I.D.) (lbs / ft) RUN (ft) RESTRICTION (.5 Lbs / ft ) HARDWARE PRESSURE TSR (3 lbs PER ft) CHOKER
(TSR)
1
⁄4" = 0.30 x = ± = + = - = ÷ 3 lbs =
5
⁄16" = 0.10 x = ± = + = - = ÷ 3 lbs =
3
⁄8" = 0.06 x = ± = + = - = ÷ 3 lbs =

NOTE: If Total System Restriction is higher than Target Pressure, use next size Beer Line I.D.

SYST EM B A LA N C E / 6 3

Potrebbero piacerti anche