AIR INDIA ENGINEERING SERVICES LTD.

ELECTRICAL O/H SHOP, DELHI


Annexure to work sheet for overhaul, check & test of A320 components

SMM APPROVAL NO. DATED:


CMM Reference: 33-47-15,Rev. 002 DATED: 01/04/2018
ANNEXURE SHEET NO. : DED/SMM/AV/EL/291, Initial issue, Rev.0

Nomenclature: LED LOGO LIGHT LH/RH Current CMM Rev: Date:


Sr. No. : Part No. : 2LA456342-01, 2LA456342-02, 2LA456342-03,
2LA456342-04
W.O. No. : IR/MIR NO.

SN. WORK DETAILS LIMITS AS PER ACTUAL SVC. AME/DT.


CMM/OHM ENGR.
4 A. VISUAL TEST

(1) Visually check the LED Logo


Light (1-1) or (1-1A) or (1-1B) or (1-
1C) for external damage. Refer
IPL(Page No. 10009) of CMM 33-
47-15

(2) There must be no external


damage to the LED Logo Light (1-1)
or (1-1A) or (1-1B) or (1-1C). Refer
IPL(Page No. 10009) of CMM 33-
47-15

B. DIELECTRIC STRENGTH TEST : (DO THIS TEST ONLY, IF WIRING IS SUSPECTED OF


DAMAGE )

(1) Apply the testing voltage 1500


V/50Hz for one minute between the
electrical contacts "A" and "B"
tied together and the Contact C and
to the Bonding Point of the
equipment.
Not more than 2.5 mA

(2) The current must not be more


No Breakdown or Flashover
than 2.5 mA.

(3) There must be no breakdown or


flashover.

Page 1 of 2
C. INSULATION RESISTANCE TEST : (DO THIS TEST ONLY, IF WIRING IS SUSPECTED OF
DAMAGE )

(1) Apply the testing voltage 500 V 500 V DC


DC between the electrical contacts
"A" and "B" tied together to the
contact “C” and the Bonding Point of
the equipment.

(2) The resistance must not be less Must not be less than
than 100 MΩ. 100 MΩ

D. BONDING MEASUREMENT :

(1) Measure the bonding resistance


measured between connector housing Must not be more than
to the farthest bonding 10 mΩ
point.

(2) Measure the bonding resistance Must not be more than


measured between Pin C (case 10 mΩ
ground) to the farthest bonding
surface point.

E. OPERATIONAL TEST :

(1) Connect the 115 V power supply 115 V


to the LED Logo Light.

(2) Set the power supply to on.

(3) Measure the EUT input


current at operating voltages of
115V/400 Hz.

(4) Malfunction is not allowed to


occur during the functional test.

(5) Remove the power supply


from the LED Logo Light.

Page 2 of 2