Sei sulla pagina 1di 1

INFORME N°

REPORT N°:
13574
ASEGURAMIENTO DE CALIDAD
FECHA
LABORATORIO DE ENSAYOS DESTRUCTIVOS DATE:
12/11/2009
QUALITY ASSURANCE - DESTRUCTIVE LAB HOJA
1 de/of 1
SHEET:

 PROCEDURE VERIFICATION
COUPON 010 QUALIFICATION  WELDING PERFORMANCE
 FILLER METAL

Welders: Orozco Omar DNI 13.842.243

Procedure EPS 003 Process SMAW


Position 1G Heat Treatment No
Filler Metal E 7018 – 2,5 mm
Filler Metal E 7018 Diameter E 7018 - 3.25 mm
Base Material IRAM 500-503 F24 Base Metal
16 mm
Thickness
OT IMPSA 1352-00 Customer ICSA

Elongation (%)ELONGACIÓN
TENSILE TEST (QW – 150)

STRENGHT (N/mm2)TENSILE

Reduction Area (%)ESTRICCIÓN


(N/mm2)STRENGHT YIELD

(N)TENSILE LOAD

FRACTURE ZONE
THICKNESS (mm)

DIAMETER (mm)

(N)YIELD LOAD
WIDTH (mm)
DIRECTION

AREA (mm2)
SAMPLE Nº

TEMP. (°C)

BASE
1 Transversal 19.20 14.00 -- Ambient 268.80 -- -- 122000 454 -- --
METAL
BASE
2 Transversal 19.50 13.90 -- Ambient 271.05 -- -- 122700 453 -- --
METAL
Base Metal Specification IRAM-IAS U500-503 – F24 -- 400-560 --

GUDED-BEND TEST (QW – 160)


Specimen # Type and figure # Result
3 QW 462.2 Side Bend Approved
4 QW 462.2 Side Bend Approved
5 QW 462.2 Side Bend Approved
6 QW 462.2 Side Bend Approved

Remarks: -
Information and samples were supplied by the customer.

We certify that the statements in this report are correct and the tests described above were tested in accordance with the requirements of
ASME Code Section IX-2007, Addenda 2008a.

REALIZÓ REVISÓ CLIENTE CUMPLE CON LA CALIDAD REQUERIDA


PERFORMED BY: CHECKED BY: CUSTOMER: SATISFIES THE REQUIRED QUALITY
NO CUMPLE CON LA CALIDAD REQUERIDA
SERGIO BONDI GABRIEL MARTIN
RESULTADO DOES NOT SATISFY THE REQUIRED QUALITY
RESULT RECHAZADO
REJECTED
PARA INFORMACIÓN
FOR INFORMATION
Rodriguez Peña 2451 - Godoy Cruz - Mendoza - CP M5503 AHY / Tel: (54-0261) 4131372 - FAX (54-0261) 4131369