Sei sulla pagina 1di 80

Model 6 Motor Control Center

Pricing Guide

Class 8998
PRICING
December 2008

CONTENTS
Description Page
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Structures and Bussing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Incoming Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Branch Feeder Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Combination Starters with Circuit Breaker Disconnects . . . . . . . . . . . . . . . . . . . . . 21
Combination Starters with Fusible Switch Disconnects. . . . . . . . . . . . . . . . . . . . . . 29
AC Drives. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Solid-State Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Unit Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Miscellaneous Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
iMCCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table of Contents

General Information AC Drives


Pricing Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Altivar® 61/71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Quote-To-Cash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Altivar 61 Variable Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Shipping Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Altivar 71 Constant Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
NEMA/EEMAC Wiring Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Solid-State Starters
Extended Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Altistart® 48 Soft Start Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Circuit Breaker Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Documentation/Witness Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Fusible Switch Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Fungus Proofing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
NEMA Type 3R Enclosure Applications for AC Drives/Soft Starts . . 45
Structures and Bussing
Structure Pricing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Options
Relays And Relay Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
NEMA/EEMAC Enclosure Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Bussing Options and Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Motor Winding Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Nameplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Insulated Horizontal Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Control Circuit Variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Structure Options And Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Back-to-Back Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Pilot Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Pilot Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Corner Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Auxiliary Electrical Interlocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Bus Duct Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Transition Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
TeSys® T Motor Management Controller . . . . . . . . . . . . . . . . . . . . . . 51
Incoming Devices Motor Logic® Solid State Overload Relays (SSOLR) . . . . . . . . . . . . . 52
Main Lug Compartments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 AC Drive Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Main Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Unit Extenders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Masterpact® Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Fusible Switch Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Tie Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Factory Installed Power Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Main Fusible Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Circuit Breaker Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Standard Wire Lug Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Micrologic® Electronic Trip Unit Options . . . . . . . . . . . . . . . . . . . . . . . 59
3-Phase 4-Wire Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Ground Fault Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Service Entrance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wiring Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
PowerLogic® Circuit Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 NEMA/EEMAC Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
PowerLogic Power Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Transient Voltage Surge Suppressors . . . . . . . . . . . . . . . . . . . . . . . . 17
Miscellaneous Units
AccuSine® Power Correction System . . . . . . . . . . . . . . . . . . . . . . . . . 61
Branch Feeder Units Distribution Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Circuit Breaker Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Distribution Panelboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Fusible Switch Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Factory Installed Panelboard Branch Circuit Breakers . . . . . . . . . . . . 63
Empty Mounting Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Combination Starters With Circuit Breaker Disconnects Full Section Empty Mounting Units (Relay Section) . . . . . . . . . . . . . . 64
Full Voltage Non-Reversing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Unwired Master Terminal Compartments . . . . . . . . . . . . . . . . . . . . . . 64
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Blank Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Application-Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Power Factor Correction Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Full Voltage Reversing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
PowerLogic Ethernet Gateways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Transparent Ready® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Application-Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Gateway Ethernet Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Reduced Voltage Autotransformer . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
High Resistance Ground Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Full Voltage Two-Step Part-Winding . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Multi-Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 iMCCs
Wye-Delta Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Closed Transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Instructions for Quote-to-Cash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Open Transition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Automation Component Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
iMCC-Network Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Combination Starters With Fusible Switch Disconnects Gateways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Full Voltage Non-Reversing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Application-Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Full Voltage Reversing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Application-Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Reduced Voltage Autotransformer . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Full Voltage Two-Step Part-Winding . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Multi-Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Wye-Delta Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

PE4 Discount Prices subject to change without notice.


0 Schedule 12/08
General Information

Pricing Instructions Instructions For Inputting Special Units And Options


Schneider Electric personnel are to use the Quote-To-Cash Into The Quote-To-Cash Quotation System
computer-based pricing system to determine motor control center
Motor Control Center Unit Special Features
(MCC) pricing and layouts.
MCC Unit Special Features are used when adding a non-supported
It is intended that this pricing guide be used for budgetary and estimation option or feature to a unit selected through the standard Quote-To-Cash
purposes. This guide provides itemized pricing for devices and options product screens, typically when adding special relays or components to
typically provided in Square D® brand MCCs from Schneider Electric. combination starters. Quote-To-Cash adds the text and pricing that you
For pricing and delivery assistance on equipment and options not listed enter, and increases the base unit’s space requirements if you indicate
in Quote-To-Cash or this guide, contact the MCC Technical Applications that added space is required.
Group (TAG) located in the Seneca, SC plant.
1. Select the desired unit using the normal MOTOR CONTROL
CENTER product screens.
Unit Only Pricing 2. Place indication in the SPECIAL PRICING field.
To price individual units to be installed in existing Model 6 MCCs, select 3. Quote-To-Cash will present a special screen for entering additional
the unit from pages 19–34, add any required options, and total the price. information. Enter the following information for pricing and delivery:
If an individual unit is to be installed in an existing NEMA/EEMAC Type 1 QUANTITY: Enter the quantity required for each unit.
Gasketed or Type 12 enclosure, add $50. for each unit to provide for the Quote-To-Cash adds the price for this quantity to each unit specified.
appropriate gasketing and doors.
DESCRIPTION: Enter a text description of the special feature. The
As with complete motor control centers, individual units should be priced quote generated by Quote-To-Cash will include this descriptive text,
using the Quote-To-Cash system. Select “Unit Only” under choices for and you will not have to manually add “notes” to describe those
Unit Type. features.
The description should include the following information:
• Manufacturer and part number and special tag quote number
Instructions For Use With The Quote-To-Cash • Function
Quotation System • Class, type, and form number, if applicable
Inputting Special Items Listed In This Guide That Are Not EXTRA MOUNTING HEIGHT: Enter the additional space required
Supported By Quote-To-Cash for one of the special features. Quote-To-Cash will multiply this
• Automatic Transfer Switches space by the specified quantity for each unit, and add this to the
“User Defined Devices” – special unit normal unit space requirements.
• Busway Connection LIST PRICE EACH: Enter the price each for the special feature.
“Incoming” – special features Quote-To-Cash multiplies the price by the quantity specified for each
unit.
• WYE-DELTA Starter Units
“User Defined Devices” – special unit LEAD TIME CODE: Enter the lead time (delivery) code for the
special feature. Quote-To-Cash will include these entries when
analyzing the schedule requirements of your MCC.
Adding Supplemental Data To The Quote-To-Cash 4. Use additional lines if necessary. If you need additional lines for the
Quotation System description, add another instance, but enter a space of 0 in. and a
It is recommended that all motor control center quotations be processed price of $0.
through the Quote-To-Cash system. Quote-To-Cash greatly reduces 5. Select “O.K.” when finished, and proceed with the rest of the quote.
errors and provides professional output which enhances the quality of If the special feature requires 20 in. deep construction, select “20 in” as
your quote. Since some of the items in this guide are not directly the LINEUP DEPTH on the GENERAL REQUIREMENTS screen. If
available from the Quote-To-Cash screens, they must be entered into there are any layout restrictions (such as TOP ONLY or ONE PER
your Quote-To-Cash quote as a SPECIAL UNIT (see Instructions For SECTION) use the DEVICE PLACEMENT option to properly lay out the
Inputting Special Units And Options Into The Quote-To-Cash motor control center.
Quotation System). There are several ways to enter these special
items; this guide indicates which method is most appropriate for each The SPECIAL PRICING fields on Quote-To-Cash give you the ability to
add virtually anything to a motor control center quote; however, Quote-
feature. In all cases, multiple lines can be added for special features.
To-Cash cannot check the accuracy of any special feature information
The text you enter into Quote-To-Cash is transferred directly to all you enter. It is up to you to be sure that all technical requirements are
Quote-To-Cash output documents; therefore, enter precise, met (such as layout restrictions or short circuit ratings). If you have any
understandable descriptions for all special features. This helps you in questions, contact the MCC TAG in Seneca.
three ways: 1) your quote will contain clear customer feature
descriptions; 2) if you need to edit the quote at a future date, the data will
make sense; and, 3) should your quote become an order, the plant will Motor Control Center System/Structure Special Features
better understand the job requirements. Use the GENERAL REQUIREMENTS screen when adding an option or
These guidelines can be used for entering special prices not listed in this feature for the motor control center structure or bus. The GENERAL
REQUIREMENTS screen can also be used to include charges such as
guide. If you are quoting a motor control center that requires a unit or
special documentation or special handling. Pricing can be entered either
feature not available on the Quote-To-Cash screens and not listed in this
guide, contact the MCC TAG with your requirements. Square D® brand per motor control center or per section. If a price per section is entered,
Quote-To-Cash multiplies that price by the total number of sections in
motor control centers are extremely versatile and can therefore be built
your final layout. Features entered with this method do not occupy unit
to nearly any customer’s requirements.
mounting space.
1. Access the GENERAL REQUIREMENTS screen. This is the first
MCC screen where information such as enclosure type and bus
amperes/material is entered.
2. Place indication in the SPECIAL PRICING field.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 1
General Information

3. Quote-To-Cash will present a special screen for entering additional 3. Quote-To-Cash will present a special screen for entering additional
information. Enter the following information for pricing and delivery: information. Enter the following information for pricing and delivery:
QUANTITY: Normally enter “1.” Quote-To-Cash multiplies the price QUANTITY: Enter “1.” If multiple units are required, specify so in the
by this quantity, and then by the number of sections, when necessary. previous screen. If additional special feature lines are used to add
Do not enter the number of sections in the motor control center. options to the special unit, enter the quantity needed for each unit,
MULTIPLY QUANTITY PER: Select LINEUP, SHIPPING SPLIT or not the total required.
SECTION as appropriate. If SECTION is selected, Quote-To-Cash DESCRIPTION: Enter a text description of the special unit. The
will multiply the price by the total number of sections in the final layout quote generated by Quote-To-Cash will include this descriptive text,
and by the quantity entered in the first question. If LINEUP is and you will not have to manually add notes to describe those units
selected, the price is multiplied by the specified quantity, but not by or features.
the number of sections. The description should include the following information:
DESCRIPTION: Enter a text description of the special feature. The • Manufacturer and part number (or special quote number)
quote generated by Quote-To-Cash will include this descriptive text, • Function
and you will not have to manually add notes to describe those • Class, type, and form number, if applicable
features. LIST PRICE EACH: Enter the price each for the special unit, and the
The description should include the following information: price each for additional features listed. Quote-To-Cash multiplies
• Manufacturer and part number (or special quote number) the price by the quantity specified for each unit.
• Function LEAD TIME CODE: Enter the lead time (delivery) code for the
• Class, type, and form number, if applicable special unit. Quote-To-Cash will include these entries when
LIST PRICE EACH: Enter the price each for the special feature. analyzing the schedule requirements of your MCC.
Quote-To-Cash multiplies the price by the specified quantities.
4. Use additional lines if necessary. If you need additional room for the
LEAD TIME CODE: Enter the lead time (delivery) code for the
description, add another instance, but enter a price of $0.
special feature. Quote-To-Cash will include these entries when
analyzing the schedule requirements of your MCC. 5. Select “O.K.” when finished, and proceed with the rest of the quote.
4. Use additional lines if necessary. If you need additional room for the If the special unit requires 20 in. deep construction, select “20 in” as the
description, add another instance, but enter a price of $0. LINEUP DEPTH on the GENERAL REQUIREMENTS screen. If there
are any layout restrictions (such as TOP ONLY or ONE PER SECTION)
5. Select “O.K.” when finished, and proceed with the rest of the quote.
use the DEVICE PLACEMENT option to properly lay out the motor
If the special feature requires 20 in. deep construction, select “20 in” as control center.
the LINEUP DEPTH on the GENERAL REQUIREMENTS screen. If
If the special unit requires multiple sections, add a special unit entry for
there are any layout restrictions (such as TOP ONLY or ONE PER
each section. The second (or third) entry does not have to include added
SECTION) use the DEVICE PLACEMENT option to properly lay out the
pricing, but should be identified as part of a multi-section unit. In either
motor control center.
the DESCRIPTION field or SPECIAL PRICING field, enter the
The special features fields on Quote-To-Cash give you the ability to add appropriate section number (“Section 1,” “Section 2,” etc.) to identify the
virtually anything to a motor control center quote; however, unit sections. Use the DEVICE PLACEMENT option to properly lay out
Quote-To-Cash cannot check the accuracy of any special feature the MCC. The sections of a multi-section unit MUST be placed next to
information you enter. It is up to you to be sure that all technical each other.
requirements are met (such as layout restrictions or short circuit ratings).
The special features fields on Quote-To-Cash give you the ability to add
If you have any questions, contact the MCC TAG in Seneca.
virtually anything to a motor control center quote; however,
Quote-To-Cash cannot check the accuracy of any special feature
Motor Control Center Special Units information you enter. It is up to you to be sure that all technical
USER DEFINED DEVICES are used when adding a unit that is requirements are met (such as layout restrictions or short circuit ratings).
completely different from any unit already included in the If you have any questions, contact the MCC TAG in Seneca.
Quote-To-Cash screens. Quote-To-Cash adds this unit to your layout
just like a standard unit, and your input provides the dimensions
required.
1. Select USER DEFINED DEVICES from the DEVICE MENU.
2. Enter the user defined device requirements:
DESIGNATION: Unit nameplate data or unit designation.
QUANTITY: The quantity of required identical special units.
DEVICE TYPE:
• Select SPECIAL UNIT for Automatic Transfer Switches and all
other special units.
DEVICE HEIGHT: Select the mounting height required for the
special unit.
SECTION WIDTH: Select the section width required. Any width
section, up to a full 35 in. wide, may be specified.
SPECIAL PRICING: Place indication in the input field.

PE4 Discount Prices subject to change without notice.


2 Schedule 12/08
General Information

Shipping Schedule NOTE: Pricing for special terms of sale, extended warranty, factory
inspections, special packaging, and documentation listed on this page
Each of the pricing tables contains a shipping column. The published
should be loaded into Quote-To-Cash as a separate line item.
shipping time for Model 6 MCCs is determined by the highest/longest
shipping code for any unit, structure, device, or option contained in that Terms of PaymentPricing
MCC. The Quote-To-Cash quotation documents will indicate the exact Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . Net 30 days from shipment
lead time in working days based on current shipping codes for the
equipment selected. Shipment Plan
FOB Factory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prepaid and allowed
The factory continually tries to meet market needs by improving the
FOB Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2% of net invoice
shipping codes for MCC components. The Quote-To-Cash system is
immediately updated when a change in shipping code is made. Warranty
Therefore, the Field should always refer to Quote-To-Cash for current 18 months from date of invoice from Schneider Electric or
shipping codes. its authorized sales channel
Approval time is the approval drawing time in factory working days after Extended to two (2) years . . . . . . . . . . . . . . . . . . . . . . .1% of net invoice
the order is received at the plant. Mail time is not included. Extended to three (3) years. . . . . . . . . . . . . . . . . . . . . .3% of net invoice
Shipping time is in factory working days after the order is released for Inspections and Reports
construction. Approval drawing time (where used) is not included. On-board Drawing Approvals . . . . . . . . . . . . . . . . . . . . . . . . .No Charge
Shipments are based on orders entered at published price levels. Physical Inspection
Check the Quote-To-Cash product lead times screen (under (No witness Testing) . . . . . . . . . . . . . . . . $1200. List per MCC per Visit
PROFILES) for current shipping schedules. Witnessed QC Inspection:
a) Class 1 Wiring . . . . . . . . . . . . . . . . . . . . .$480. List per Section
b) Class 2 Wiring . . . . . . . . . . . . . . . . . . . . .$720. List per Section
NEMA/EEMAC Wiring Classes And Types
Certified Test Reports . . . . . . . . . . . . . . . . . . . . . . . .$900. List per MCC
Class 1—Independent Units: Class 1 motor control centers (MCCs)
consist of mechanical groupings of combination motor control units, Packaging
feeder taps, other units, and electrical devices arranged in a convenient Moisture- and Fungus-Proofing
assembly. The manufacturer completes wiring between components . . . . . . . . . . . . . . . . . . . . $1200. List set-up, plus $800. List per Section
within each unit. Connections between units are not provided. Export Packaging . . . . . . . . . . . . . . . . . Contact International Marketing
Class 2—interconnected Units: Class 2 MCCs are the same as Class Documentation
1 MCCs with the addition of manufacturer-furnished electrical Approval Drawings
interlocking and wiring between units as specifically described in the 6-12 prints or 1 print and 1 reproducible . . . . . . . . . . . .No Charge
overall control system diagrams supplied by the purchaser. Additional Sets . . . . . . . . . . . . . . . . . . . . . . . . . . $600. List per Set
Type A: User field wiring connects directly to internal control device As-built Drawings
terminals in the unit and is provided only on Class 1 MCCs. 6-12 prints or 1 print and 1 reproducible . . . . . . . . . . . .No Charge
Type B: User field control wiring connects directly to the control unit Additional Sets . . . . . . . . . . . . . . . . . . . . . . . . . . $600. List per Set
terminal block(s) in or adjacent to each unit, and user field load wiring Reproducible Mylar Drawings . . . . . . . . . . . . . . .$300. List per Section
connects directly to the device adjacent to the vertical wireway. User Custom Drawing Requirements (NEMA ICS 18 Class I-S and II-S)
field load wiring for Size 3 or smaller combination starter units connects Interconnect Wiring (as specified) . . . . . . . . . . . .$300. List per Section
as follows: CAD Drawing Exchange Format (DXF) . . . . . . . . . . . . . . . . .No Charge
Type B-D: User field load wiring connects directly to the device Model 6 Instruction Bulletin
terminals. Shipped with MCC . . . . . . . . . . . . . . . N/C (Maximum of 3 Books)
Additional Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . $40. List per Set
Type B-T: User field load wiring connects to factory wired power
terminal blocks located in or adjacent to each unit. Custom Manuals
Instruction manuals plus record drawings, component data sheets,
Quote-To-Cash offers Class 2 Type B. This equals B-D.
and wiring schedules . . . . . . . . . . . . . . . . . . . . $600. List each Set
If B-T is required, select power terminal blocks in unit options.
User field load wiring for Size 4 or larger combination starter units
connects directly to the device terminals. See page 60 for pricing
information.
Type C: User field control wiring on all units and load wiring on Size 3 or
smaller units connect directly to master terminal blocks mounted at the
top or bottom of those vertical sections containing control units. Control
wiring on all units and load wiring on Size 3 or smaller units are factory-
wired to their master terminal blocks. User field load wiring for Size 4 or
larger units connects directly to the device terminals. See page 60 for
pricing information.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 3
Structures and Bussing

Structure Pricing Price Per Section Shipping


Main Bus Amps And Material q Code
Each section provides 72 in. of mounting space for MCC units. Special Standard Industrial
sections are required for some units such as autotransformer starters
600 A Tin-Plated Aluminum — N/A
and some main breakers. However, all sections are priced in the same
manner. 600 A Tin-Plated Copper $ 186. —

Structures are priced per section, then multiplied by an estimated 600 A Silver-Plated Copper 438. $ 252.
number of sections required for the order. Refer to the pricing 800 A Tin-Plated Aluminum 100. N/A
instructions at the front of this guide to determine the number of sections 800 A Tin-Plated Copper 286. 100.
required. B
800 A Silver-Plated Copper 608. 422.
Structures include vertical ground bus, 42,000 A bus withstand rating.
1200 A Tin-Plated Aluminum 438. N/A
Price Per Section Shipping 1200 A Tin-Plated Copper 662. 476.
NEMA/EEMAC Enclosure Type Depth
Standard Industrial Code 1200 A Silver Plated Copper 1152. 966.
General Purpose Type 1 $3880. $4440. 1600 A Tin-Plated Copper (20 in. deep only) 826. 640.
General Purpose Type 1 Gasketed 15 in.— 1600 A Silver-Plated Copper (20 in. deep only) 1594. 1408.
4150. 4710. B C
(often referred to as Type 1A) Standard
20 in.— 2000 A Tin-Plated Copper (20 in. deep only) 1070. 884.
Industrial Duty Type 12 4570. 5130.
$334. 2000 A Silver-Plated Copper (20 in. deep only) 2192. 2006.
Outdoor Duty Type 3R Non-Walk-In 9596. 9800. C (per
section) 2500 A Tin-Plated Copper c 1470. 1284.
Outdoor Duty Type 3R Walk-In D
(Contact Project Support and Engineering Center in Nashville) 2500 A Silver-Plated Copper c 2592. 2406.
For 3Ø4W systems, see page 13.

q Ratings shown based on 65 °C max. Temperature rise per UL 845. Consult the
MCC TAG for current density ratings.
c Not available in NEMA 12 or 3R enclosure type. Includes charge for 2 in. wide
horizontal bus.

Bussing Options And Modifications


All modification prices are per section, except where noted.
Price Per
Section Shipping
Description
Code
Standard Industrial
Bus Bar Surge Protection (Price per Motor Control Center)
$1428. $1428. D
(Requires 6 in. mounting space near the incoming feeder.) Not UL Listed. Not for use on ungrounded systems.
300 A Vertical Bus—Tin Plated Copper N/C N/C B
Substitute 600 A Vertical Bus – Tin Plated Copper 800. 800.
C
Substitute 600 A Vertical Bus – Silver Plated Copper 1275. 1275.
4 Bolt Splice (captive) on Main/Horizontal Bus N/C N/C
42,000 A rms N/C N/C B
Bus Withstand Rating 65,000 A rms 508. 508.
(Modifications to increase the bus system withstand rating to meet available fault
current requirements.) Does not increase individual unit ratings. 85,000 A rms 702. 702.
D
100,000 A rms a 1070.p 1070.p
Tin-Plated Copper Vertical Ground Bus 56. N/C C
Tin-Plated Copper Horizontal Ground Bus—1/4 in. x 1 in. (Rated 300A) N/C N/C
B
Tin-Plated Copper Horizontal Ground Bus—1/4 in. x 2 in.f 120. 120.
Silver-Plated Copper Horizontal Ground—1/4 in. x 1 in. (Rated 300A) 240. 240.
F
Silver-Plated Copper Horizontal Ground—1/4 in. x 2 in. (Rated 600A) 400. 400.
Optional 2 in. Main/Horizontal Bus – Tin-Plated Copper f 586. 400. D
Optional 2 in. Main/Horizontal Bus – Silver-Plated Copper f 586. 400. D
Standard Section (600–1600 A) 1500. 1500.
Main Lug Section (600–1200 A) 1500. 1500.
Main Lug Section (1600 A) 2500. 2500.

Insulated Horizontal Bus Main Circuit Breaker/Fusible H


Switch Section (600–800 A) 1500. 1500.
[unit mounted type]
Main Circuit Breaker/Fusible
Switch Section (600–1600 A) 2500. 2500.
[full section type]
a 480 V maximum.
f Standard on 2500 A Horizontal Bus.
p $1350. for 2500 A Horizontal Bus.

PE4 Discount Prices subject to change without notice.


4 Schedule 12/08
Structures and Bussing

Structure Options And Modifications All modification prices are per section, except where noted.

Price Per
Section Shipping
Description Code
Standard Industrial
12 in. High Pull Box $ 746. $ 746.
18 in. High Pull Box 1114. 1114.
B
Two-Piece Top Plate 242. 242.
Bottom Plate 72. 72.
Drip Hood (Not available with 2500 A horizontal bus) 290. 290. F
Strip Heater
(Not available in sections with Size 6 RVAT, bottom feed main lugs, bottom feed mains and branches 716. 716. B
over 600 A, or distribution transformers)
Thermostat for Control of Strip Heater (6 heaters maximum; price per thermostat) 640. 640. F
Seismic Certification 196. 196. C
12 in. = 78 in. H G
Reduced Height Section (Not Available in NEMA 3R) 18 in. = 72 in. H 1562. 1562. C
24 in. = 66 in. H G
Add 72 in. to space Add 72 in. to space
Back-to-Back Splice Transition Section (Available with Neutral Bus) 2500 A max. calculation calculation C

Through-the-Back Splice (Not Available with Neutral Bus) q 1200 A max. 2058. 2058. F

Corner Section (Not available in NEMA/EEMAC Type 3R Construction or Reduced Height 4150. 4150.
2500 A max. and Add 72 in. to and Add 72 in. to C
Sections) space calculation space calculation

9 in. Wide Vertical Wireway (Sections 25 in. wide. This option applies only to sections with plug-in units) 702. 702.
Wire Tie Retainers in Vertical Wireway 54. 54. B
Vertical Bus Barrier Closing Shutters (Manual Shutters) N/C N/C
Auto-shutter All plug-on units 312. 312. C
NEMA/EEMAC Type 1,
968. 968.
Non-Standard Exterior Color (Includes one coat of Schneider Electric-selected 1 Gasketed, or Type 12
paint.) Consult factory for specifications detailing primers, paint, H
NEMA/EEMAC Type 3R 1938. 1938.
thickness, and application process.
Unit Only 150. 150.
Fishtape barrier
320. N/C C
(Prevents rising of bottom-entering fishtapes into wireway.)
Rodent Barriers N/C N/C B
GFI Receptacle (NEMA/EEMAC Type 3R Non-Walk-In) 1200. 1200.
G
Fluorescent Light (NEMA/EEMAC Type 3R Non-Walk-In) 1700. 1700.
q Tin plated copper standard. Other bus material has shipping code H.

20.00
508
12.00 20.00 or
305 508 25.00
635
20.00
508
31.00 or
787 25.00
or 635
41.00
1041 15.00 15.00
1.00 381
1.00 381
Front
25 25
Between or Between or
Sections 20.00 Sections 20.00
Back-To-Back Transition Section 508 Through-The-Back Splice 508
Top View Top View
Corner Section
Top View

Prices subject to change without notice. PE4 Discount


12/08 Schedule 5
Structures and Bussing

Bus Duct Connection I-Line® feeder busway compartments should always be located at the
top of the section. A 12 in. high pull box is required (price included).
W
I-Line busway should be positioned edgewise A, B, C, left-to-right as
W/2
shown in the figure. To facilitate easy installation, both front and side
accessibility is recommended. No additional mounting space is
required.
Pricing for 3 Phase-3 Wire top located I-Line busway only. Consult the
Typical MCC TAG for other applications.
A B C
D MCC NOTE: Busway flanged end is not included in price. Must be “I-Line II
CL Section
Feeder End” Style; Qwik Flange is Not Available. NEMA Type 3R not
available. Bus duct connections are not UL Listed in MCC’s.
D/2
CL

Front
Top View

No Main Disconnect q C/B Disconnect c Fusible Main Disconnect c


MCC Bus MCC Mains MCC Mains
Width Depth Connq Price Width Depth Conn q Price Width Depth Conn q Price
Ampacity Ampacity Ampacity
600 A 15 $2688.
800 A 20 or Bus 2812. 110 A–600 A 20 15 or 20 Cable $1808. 200 A–600 A 20 15 or 20 Cable $1938.
1200 A 20 3312.
1600 A 3562.
2000 A f 20 Bus 800 A–1200 A 20 20 Bus 3312. 800 A–1200 A 20 20 Bus 3312.
3938.
— — — — — 1600 A–2500 A 25 20 Bus 3938. 1600 A–2000 A 25 20 Bus 3938.
q With no Main Disconnect, connection from busway to horizontal bus is done with bus. Main Lug compartment is not required.
c With a Main Disconnect, connection from busway to disconnect is done with either cable or bus depending on ampacity.
f For 3P3W, a 25 in. wide section is standard; it contains 9 in. wireway and will accept plug-on units. 72 in. unit mounting space is available. For 3P4W (left to right orientation),
a 30 in. wide section is required. For 3P4W (front to rear orientation), a 25 in. wide section is required.
NOTE: Shipping Code G Transition Bussing Modifications
Shipping
Model 4 Bus Model 6 Bus Price
Model 4 To Model 6 Transition Section Code
(Not Available In NEMA/EEMAC Type 3R Construction) 600 A Aluminum or Copper 600 A Copper N/C
800 A Aluminum 800 A Copper N/C
Provides transition from existing Model 4 to a new Model 6 MCC. The
1000 A Aluminum (2) 2 in. 1200 A Copper $ 688.
transition requires a 12 in. extension on the first section of the Model 6
lineup. A transition section does not affect the space calculation when 1200 A Aluminum (2) 3 in. 1200 A Copper 688.
estimating the number of sections during pricing. The transition 1000 A Aluminum (1) 4 in. 1200 A Copper 688.
section must be ordered with at least one Model 6 section and 1200 A Copper (2) 2 in. 1200 A Copper 906.
C
cannot ship separately. The Model 6 ampacity must be equal to or 1000 A Copper (1) 3 in. 1200 A Copper 906.
less than the ampacity of the Model 4 bus. Neutral bus is not 1200 A Copper (1) 4 in. 1200 A Copper 906.
supported. 1400 A Aluminum (2) 4 in. 1600 A Copper 1090.
Transition pricing procedure: 1600 A Copper (2) 3 in. 1600 A Copper 1090.
1. Price the new Model 6 section(s). 1800 A Copper (2) 4 in. 2000 A Copper 1370.
2000 A Copper (2) 4 in. 2000 A Copper 1370.
2. Select a transition section orientation from Basic Transition Table
below.
3. Add any modifications for bus type or ampacity from Transition
Model 5 To Model 6 Transition
Bussing Modification Table below. 800 A copper bus is standard. Model 6 MCCs will splice directly to a Model 5 MCC, provided the
NOTE: Splice bars are included with transition section. Model 5 structure was built after May 1992.
If the Model 5 MCC was built prior to May of 1992, contact the MCC
The transition section will match the depth of the Model 6 MCC, and can
TAG in Seneca. Custom splice plates will be required and supplied with
be used to splice a front-of-board Model 6 to an existing back-to-back
Model 4 MCC (20 in. deep). The transition section will be rear aligned the first section in the Model 6 lineup depending on which side of the
existing Model 5 line-up the Model 6 is installed.
with both the Model 4 and the Model 6 sections. On 3-Phase 4-Wire
systems, the 3-phase bus bars will splice together, but the Model 4
neutral bus bar will not be carried through in the Model 6. Switchboard To Model 6 Transition
When ordering Model 4 to Model 6 transition section, the original Square D® brand switchboards can be provided with bussed transitions
Model 4 factory order number must be provided. to Model 6 Motor Control Center lineups. Refer to the QED Switchboard
Pricing Guide for pricing and delivery schedule.
Shipping
Basic Transition a Price
Code
Model 4 on left and Model 6 on right
$2058. C
Model 6 on left and Model 4 on right
aIncludes 12 in. wide structure with 800 A bus as standard.

PE4 Discount Prices subject to change without notice.


6 Schedule 12/08
Incoming Devices

Main Lug Compartments


• Main lug compartments must be specified in the absence of other incoming line provisions.
• Price for 3Ø4W main lugs includes neutral assembly for cable connection to other units with solid neutrals.
• Main lug units short circuit ratings to 100,000 A are available.
• Shipping codes listed are for standard lug wire ranges, see page 12. Other wire range lugs are available—shipping code F.
NOTE: Main lugs ampacity must equal horizontal bus ampacity to meet published deliveries.

Top Located Main Lug Compartments Bottom Located Main Lug Compartments
Space Shipping Space Shipping
System Lug Ampacity Price System Lug Ampacity Price
(Inches) Code (Inches) Code
600k $ 700. 600 $1042. 18
6 B
800 950. B 1200q 2360. 36
3-Phase
3-Phase 1200 1860. 12 3-Wire 1600f 3134.
3-Wire C
1600f 3134. 2000f 3686. 72
C
2000f 3686. 72 2500f 4486. D
2500f 4486. D 600 1662. 18
600k 980. 1200q 3322. 36
9 3-Phase C
800 1350. B 4-Wire
1600f 4436.

3-Phase 1200q 2600. 12 2000f 4988. 72


4-Wire 1600f 4436. 2500f 5788. D
C
2000f 4988. 72
2500f 5788. D
k Not available @ 100,000 A.
q 25 in. wide section with 9 in. wireway
f 30 in. wide by 20 in. deep section

Prices subject to change without notice. PE4 Discount


12/08 Schedule 7
Incoming Devices

Main Circuit Breakers


• Main circuit breaker units are located in 20 in. wide by 15 in. or 20 in. • 100% rated units can be selected below as an option.
deep sections, except where noted. Mains must be mounted at the • Main units rated 800A and above are bus connected to the horizontal
top or bottom of the MCC section. bus. 300-600A main units are cabled to the horizontal bus.
• Select Trip Rating and desired Unit Interrupting rating. • Shipping codes listed are for standard wire lug ranges. See “Main and
• All units are for 3Ø3W systems. For 3Ø4W applications, see Branch Circuit Breaker Lug Ranges” on page 12. Other wire range
“3 Phase/4 Wire Systems” on page 13. lugs are available—shipping code F.
• 80% rated thermal-magnetic molded case circuit breakers are • Units are available with gray or white interiors without affecting the
standard. 800A and above are basic electronic trip (ET trip system) delivery listed below. Deduct $180. from list price below for gray units.
with LI functions only and do not have field interchangeable sensors
or trip units. Optional Electronic Trip Circuit Breakers are available for
L-, P-, and R-frame breakers; see “Circuit Breaker Micrologic®
Electronic Trip Unit Options” on page 59.

Thermal-Magnetic, Molded Case Circuit Breakers


Breaker Trip Breaker Frame Unit Interrupting Rating (kA) Shipping
Breaker Type Price Space (Inches)
Ratings (Amps) (Amps) 208/240 V 480 V 600 V Code
Standard (80%) Rated
65 35 18 $1380.
15-60 100 65 25 1680.
100 100 50 2150.
65 35 18 1450.
70-100 150 HG/HJ/HL 100 65 25 1780. 12 (Plug On)
100 100 50 2500.
65 35 18 2520.
110-150 100 65 25 3320.
100 100 50 4320.
65 35 18 2760. B
175-225 100 65 25 3650.
100 100 50 4750.
250 JG/JJ/JL 18 (Plug On)
65 35 18 3160.
250 100 65 25 4190.
100 100 50 5460.
400 LH 65 35 25 6070. 21 (Top Entry)
300-400
600 LI 100 100 100 7770. 27 (Bottom Entry)

8280. 24 (Top Entry)


450-600 600 LI 100 100 100 36 (Bottom Entry)
800 MJ 65 65 25 10570. 18 (Top Entry)
800
1200 PL/PK 100 100 50 14000. 36c (Bottom Entry)
21 (Top Entry)
1200 1200 PL/PK 100 100 50 15250. 36c (Bottom Entry)
25560. 72 c
1600q 3000 RL/RK 100 100 65 C
(20 W X 20 D)
27140. 72 c
2000q 3000 RL/RK 100 100 65
(20 W x 20 D)
72 c
2500q 3000 RL/RK 100 100 65 31500. (25 W x 20 D)
NEMA 1/1A only
Optional 100% Rated
NOTE: All 100% rated circuit breakers are molded case with Micrologic® electronic trip. LE electronic trip circuit breakers include Full Function Trip Unit with LSI tripping
functions. P and R-frame electronic trip circuit breakers include Basic 3.0 Trip Unit with LI tripping functions.
24 (Top Entry)
100-400 400 LE 100 65 35 12404.
36 (Bottom Entry)
F
600 1200 PL/PK 100 100 50 14000. 18 (Top Entry)
36c (Bottom Entry)
21 (Top Entry)
800 1200 PL/PK 100 100 50 15250.
36 c (Bottom Entry)
72 c
1200q 1200 PL/PK 100 100 50 21250. (20 W x 20 D)
NEMA 1/1A only
C
72 c
1600q 3000 RL/RK 100 100 65 29560.
(20 W x 20 D)
72 c
2000q 3000 RL/RK 100 100 65 35500. (25 W x 20 D)
NEMA 1/1A only
q Specify top or bottom entry.
c Requires single shipping split.

PE4 Discount Prices subject to change without notice.


8 Schedule 12/08
Incoming Devices

Optional Masterpact® Power Circuit Breaker Main Units— Stored Energy/Drawout Style/Insulated Case
Enter into Quote-To-Cash as a USER DEFINED DEVICE (see page 2). All Masterpact circuit breakers are equipped with the Micrologic
Masterpact NT and NW Power Circuit Breakers are available in Electronic Trip System. Two trip unit models are available: 5.0 Basic and
Model 6 Motor Control Centers as an incoming main device. These 6.0 Power. The MCC Masterpact NT/NW main circuit breaker comes
circuit breakers contain a two-step stored energy mechanism which with Basic 5.0 trip units as standard, with LSI tripping functions:
provides 5-cycle maximum closing in both manually and electrically long-time trip, long-time trip delay adjustments, short-time trip,
operated types. short-time trip delay adjustment, and instantaneous trip. The optional
6.0P Micrologic trip unit offers LSIG tripping functions: long-time trip,
MCC Drawout Main Circuit Breaker features include: long-time trip delay adjustments, short-time trip, short-time trip delay
• UL 845/CSA listed with UL 489 version, 80% rated circuit breakers adjustments, instantaneous trip, ground fault trip, and ground fault trip
(100% not available UL/CSA listed in MCC) delay adjustment.
• Stored energy breaker mechanism The MCC Masterpact drawout breaker package is offered in two
• Internal barriers for separating line, load, and control areas accessory groups—Limited and Enhanced—to help in selecting and
• Micrologic® trip units (Standard 5.0 included, 6.0P with Ground Fault pricing the most popular options. See the Accessory Group descriptions
optional). on page 10 for the Masterpact options included in each accessory
• Modbus® communications for Web-enabled power and control group. Refer to the Masterpact NT/NW Universal Power Circuit Breaker
compatibility is optional Catalog # 0613CT0001R10/03 for a full description of the trip units and
• Fully bussed power circuit the accessories.
• Control compartment including trip unit power supply and additional
panel space Main Circuit Breaker Unit Interrupting Ratings per UL 845/
• Optional Low Flash versions are tested to show the arc flash hazard CSA
risk category referenced by NFPA 70E
Circuit Breaker Type 240 V 480 V 600 V
(Interrupting Rating Code) Delta Delta or Wye Delta or Wye
800-1200A NT (H) 65 50 50
800-1200A NT (L1) 100 65c —
800-2500A NW (N) 65 65 50
800-2500A NW (H) 100 100 65
800-2500A NW (L) 100 100 65
c 100 kA interrupting rating is available by ordering optional Arc Flash (LF) version.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 9
Incoming Devices

Masterpact Main Circuit Breakers


MCC Unit Short Circuit Rating List Price
(kA) Circuit
Breaker Shipping
Unit Type and Amps c Breaker Space (Inches)
Frame Limited Enhanced Code
240 V 480 V 600 V Model No.
Accessories Accessoriesq

Top Entry
M6MDT800H 65 50 50 NT08H 43644. 71605.
M6MDT800L1 f 100 65 — NT08L1 72 44644. 72605.
NT
M6MDT1200H 65 50 50 NT12H (25 W x 20 D) 51444. 79405.
M6MDT1200L1 f 100 65 — NT12L1 f 52444 80405.
M6MDT1200NWN a 65 65 50 NW12N 71444. 99405.
3W
M6MDT1200NWL fa 100 100 65 NW12L Two full sections required 77444. 105405. H
1 @ (30 W x 20 D)
M6MDT1600N a 65 65 50 NW16N 1 @ (20 W x 20 D) 73844. 101805.
NW M6MDT1600L fa 100 100 65 NW16L 79844. 107805.
4W
M6MDT2000N a 65 65 50 NW20N Two full sections required 82244. 110205.
1 @ (30 W x 20 D)
M6MDT2000L fa 100 100 65 NW20L 1 @ (25 W x 20 D) 88244. 116205.
(Not available in NEMA 3R
M6MDT2500H ad 100 100 65 NW25H 99244. 127205.

Bottom Entry
M6MDB800H 65 50 50 NT08H 43644. 71605.
M6MDB800L1 f 100 65 — NT08L1 72 44644. 72605.
NT
M6MDB1200H 65 50 50 NT12H (25 W x 20 D) 51444. 79405.
M6MDB1200L1 f 100 65 — NT12L1 f 52444. 80405.
M6MDB1200NWN 65 65 50 NW12N 53844. 81805.
M6MDB1200NWL f 100 100 65 NW12L 59844. 87805. H
M6MDB1600N 65 65 50 NW16N 56244. 84205.
3W or 4 W
NW M6MDB1600L f 100 100 65 NW16L 72 H x 30 W 62244. 90205.
(20 D)
M6MDB2000N 65 65 50 NW20N 64644. 92605.
M6MDB2000L f 100 100 65 NW20L 70644. 98605.
M6MDB2500H d 100 100 65 NW25H 81644. 109605.
c Enter into Quote-To-Cash MCC Product Selector as a User Defined Device using the Unit Type as the description. Add the sections described in the Space column and
Price column. Remember to include price adders and suffixes for arc flash or enhanced accessories if needed.
q Add suffix “E” to Unit Type for Enhanced Accessory Group to be included on main unit.
f Add $8000. for Low Flash version and change the “L1” (NT) or “L” (NW) suffix to “LF”. Tested to show the arc flash hazard risk category as referenced in NFPA70E.
NOTE: Short circuit rating of LF is 100 kA @ 480 V.
a Top entry mains must be at the end of the MCC lineup. Top entry mains ship as two shipping splits: one 30 in. wide section for the breaker and one 20 in. wide section
(25 in. wide for 4W) as an incoming cable section. No through bus is included in the incoming cable section.
NOTE: Bottom entry can be at the end or middle of the MCC lineup.
d Available as NEMA 1/1A only.

MCC Masterpact Main Accessory Groups Enhanced Accessory Group includes:


Limited Accessory Group includes: • 6.0P trip unit (LSIG)
• 5.0 trip unit (LSI) • Sensor Plug = Unit Amp Rating
• Sensor Plug = Unit Amp Rating • Rating plug “A”
• Rating plug “A” • Modbus® breaker communications module and 24 Vdc
• No communications communications power supply, unwired to MCC network
• 4 Form C auxiliary switches • 4 Form C auxiliary switches
• 1 Form C overcurrent trip switch • 1 Form C overcurrent trip switch
• Padlockable push button cover • Padlockable push button cover
• Transparent cover over front of circuit breaker (NEMA 12 only) • Transparent cover over front of circuit breaker (NEMA 12 only)
• Automatic cradle shutters with padlocking provisions • Schneider key interlock for circuit breaker
• Spring charging motor (120Vac)
• Shunt trip without communications (120Vac)
• Shunt close without communications (120Vac)
• Electric reset (120Vac)
• Ground fault
• Neutral CT (4-wire model only)
• Automatic cradle shutters with padlocking provisions

PE4 Discount Prices subject to change without notice.


10 Schedule 12/08
Incoming Devices

Tie Breakers NOTE: Neutral bus is not available in the tie breaker, therefore the
neutral is not continuous nor switched through the tie. Contact
Enter into Quote-To-Cash as a USER DEFINED DEVICE (see page 2).
MCC TAG for applications requiring continuous or switched neutral.
Tie Breakers are used to connect two MCCs together to allow either MCC
The prices below are for a manual throwover of the tie breaker.
Main to feed both MCCs as required. The tie breaker consists of a
Automatic throwover systems controlled by a programmable logic
PowerPact® or Masterpact® circuit breaker and hard bus transition to
controller can be provided for PowerPact P-frame or Masterpact NW
complete the connection between the power buses from each MCC. Trip
circuit breakers in the MCC. Contact MCC TAG for pricing and space of
Rating, Frame Amps, and Breaker Frame of the tie breaker should match
automatic throwover systems.
the main.

Trip
Description Rating Frame Breaker Frame Price Tie Breaker Total Space Shipping
(Amps) Adder c (Inches) c Code
(Amps)

Standard 80% Rated


800 MJ
800 $ 6250. 72 (20 W x 20 D)
1200 PL/PK
1200 PL/PK 8750. 72 (20 W x 20 D)
72
1200 Two full sections required
3000 Masterpact Drawout NW 21250.
1 @ (30 W x 20 D)
1 @ (20 W x 20 D)
72
Two full sections required
RL/RK 24250. 2 @ (20 W x 20 D)
MCC 1 MCC 2 2000 3000
(Not available in NEMA 3R)
72 G
Two full sections required
Masterpact Drawout NW 26250.
1 @ (30 W x 20 D)
1 @ (20 W x 20 D)
72
Two full sections required
Tie RL/RK 28000.
1 @ (25 W x 20 D)
1 @ (20 W x 20 D)
NEMA 1/1A only
2500 3000 (Not available in NEMA 3R
72
Two full sections required
Masterpact Drawout NW 30000. 1 @ (30 W x 20 D)
1 @ (20 W x 20 D)
NEMA 1/1A only
Tie Breaker Arrangement
Optional 100% Rated
800 1200 PL/PK 8750. 72 (20 W x 20 D)
72
1200 1200 PL/PK 11250. (20 W x 20 D)
NEMA 1/1A only
G
72
Two full sections required
2000 3000 RL/RK 28000. 1 @ (25 W x 20 D)
1 @ (20 W x 20 D)
NEMA 1/1A only
cTo price the tie breaker, price a Main Breaker of equivalent rating with a Key Interlock option and then add the Price Adder above. Tie breaker total space will be as shown,
and includes a bus transition between two MCCs and the tie breaker. Each MCC Main must also include the key interlock option.

Example: 1200 A, PL/PK


Main Breaker Price $15,250.
Tie Price Adder 8,750.
Key Interlock Adder 968.
Total Tie Breaker Price $24,968.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 11
Incoming Devices

Main Fusible Switches


• Main fusible switch units are located in 20 in. wide by 15 in. or 20 in. Main and Branch Circuit Breaker Lug Ranges
deep sections, except where noted. Mains must be mounted at the Circuit Breaker
Amps Standard Lug Wire Range
Lugs Per
top or the bottom of the MCC section. Frame Phase
• All main switches use automatic molded case switches in series with H 150 14–3/0 1
Class R fuse clips (up to 600 A) or L fuse clips (above 600 A). J 175 4–4/0 1
J 250 3/0–350 kcmil d 1
• Motor Control Center unit short circuit ratings up to 100,000 A are
(2) 1–250 kcmil
available with the use of Class R, J, or L fuse clips. LA/LH 125–400 or 1
• Fuses are not included. To order factory installed fuses, see “Factory (1) 1–600 kcmil
Installed Fuses” on page 57. LI/LX/LE/LXI 300–600 (2) 4/0–500 kcmil 1
3/0–500 kcmil (standard) 3
• All units are for 3Ø3W systems. For 3Ø4W applications see “3 Phase/ M/P 700–800 3/0–600 kcmil Cu or Al; 750 kcmil
4 Wire Systems” on page 13. 2
compacted aluminum only (optional)
• Shipping codes listed are for standard lug wire ranges, see “Main and 3/0–500 kcmil (standard) 4
Branch Fusible Switch Lug Ranges” on page 12. Other wire range 350–600 kcmil Cu or Al (optional) 3
P 1000–1200
lugs are available—shipping code F. 3/0–600 kcmil Cu or Al; 750 kcmil
3
compacted aluminum only (optional)
• Units are available with gray or white interiors without affecting the
delivery listed below. Deduct $180. from list price below for gray units. R 1600–2500 1/0–750 kcmil 6
NT Drawout 800–1200 3/0–500 kcmil 4
NW Drawout 800–2500 3/0-750 kcmil (top entry) 8
Main Fusible Switches 3/0-500 kcmil (bottom entry)

Maximum Fuse Size (A) Shipping d Wire size is limited to 250 kcmil on Compac™ 6 units.
Price Space (Inches)
600 V Max. Code
200 $ 1910. 24 (plug-on) Main and Branch Fusible Switch Lug Ranges
400 4172. 45 (Top Entry)
54 (Bottom Entry) Main Switch Amps Standard Lug Wire Range Lugs Per Phase
600 6950. 60 30 #12–4 1
800 13990. 60 (Top Entry) B
60q (Bottom Entry) 60 #8–1 1

1000c 17660. 72 q (20 W X 20 D, Top Entry) 100 #14–2 1


60q (Bottom Entry)
200 #1 AWG–300 kcmil (branches) 1
1200c 20780. 72 q (20 W X 20 D, Top Entry) #4–4/0 (mains)s
60q (Bottom Entry)
1600c 22730. 72q (30 W X 20 D) (2) #1–250 kcmil
C 400 or 1
2000c 24670. 72 q (30 W X 20 D)
(1) #1–600 kcmil
q Requires a single shipping split.
c Specify top or bottom entry. 3/0–500kcmil 3
600 3/0–600 kcmil Cu or Al;
Special Note For All Main Devices 800 750 kcmil compacted aluminum 2
450 A or larger branches cannot be installed in the same vertical section only (optional)
as a 300 A or larger main device.
3/0–500 kcmil (standard) 4

Standard Wire Lug Ranges (Mechanical)f 1000


350–600 kcmil (standard) 3
1200 3/0–600 kcmil Cu or Al;
f Compression lugs are available; see page 60 for pricing and details.
750 kcmil compacted aluminum 3
only (optional)
Main Lugs 1600
1/0–750 kcmil 6
2000
Main Lug Amps Lug Wire Range Lugs Per Phase /Neutral
s Lugs for up to 250 kcmil wire are available. Contact factory for AL250JD lug kit
600 3/0–500 kcmil 2 if larger lugs are needed.
800 3
1200 3/0–600 kcmil 4a Neutral Lug Ranges
1600 6
3/0–750 kcmil Application Lug Wire Range
2000, 2500 6
100 A Main or Branch (2) #14–1/0
a Up to 750 kcmil wire size can be used if a 12 in. pull box is ordered.
h Mechanical lugs are standard. Compression lugs are available; see page 60. 200–250 A Main or Branch (2) #4–300 kcmil
400–600 A Main or Branch (2) 3/0–500 kcmil
800 A Main or Branch (3) 3/0–500 kcmil
1000 A Main or Branch
1200 A Main or Branch
(4) 3/0–750 kcmil
1600–2500 A Main or Branch
800–1200 A NT Drawout (4) 3/0–500 kcmil
(8) 3/0–750 kcmil (Top Entry)
1200–2500 A NW Drawout
(8) 3/0–500 kcmil (Bottom Entry)
600–2500 A Main Lugs See Main Lugs Table at left
(4) 3/0–750 kcmil
Neutral Rating 1250 A Max.
(14) #6–300 kcmil
600–800 A (1) 1.5 in. x 1/4 in. Cu
1200–2000 A (2) 1.5 in. x 1/4 in. Cu Holes drilled for customer variations
Max. 100% Rating is 1250 A

PE4 Discount Prices subject to change without notice.


12 Schedule 12/08
Incoming Devices

3 Phase/4 Wire Systems


If the motor control center contains only motor loads, and no future 4-wire bus, but holes are pre-drilled to accommodate user-mounted lugs. As an
loads are anticipated, it is not necessary to bring the neutral option, neutral conductors for loads can be connected to the MCC
conductor into the MCC. As an option, a neutral lug assembly (see Fig. 1 neutral bus via a Neutral Bus Drop (see Fig. 2 below) located in each
below) can be provided in the incoming main section to terminate a neutral vertical wireway for easy access.
conductor. Additional lugs can be added for connections to the neutral. Also, a special 12 in. neutral distribution unit (see Fig. 3 below) can be
When 4-wire loads are present in the MCC, solid neutral bussing (see provided to terminate branch device neutral connections in 15 in. deep
Fig. 2 below) can be provided in individual sections and connected to sections. Such branches should be located close to the main for easier
provide a continuous neutral bar. A Neutral Lug Termination option must interconnections. A Neutral Lug Termination option must be selected
be selected for the incoming main section when selecting Solid Neutral when selecting a Neutral Distribution Unit.
Bus in the MCC. Lugs are not provided when selecting solid neutral Shipping codes listed are for standard lug wire ranges (see page 12).

Description Application Price Space (Inches) Shipping Code


110–150 A Main or Branch c $ 96. 0
175–250 A Main or Branch c 152. 0
300–400 A Main or Branch t 394. 0
450–600 A Top Located Main Breaker 18
Neutral Lug Termination a 766.
450–600 A Branch Breaker or Bottom Located Main Breaker 6 C
(Provides termination for fourth wire on 3-phase/
4-wire systems) 600–800 A Main Switch or Top Located Branch Switch 5 in. added to width
600–800 A Bottom Located Branch Switch 0
1302.
1000–2000 A Main or Branch Switch
5 in. added to width
800–2500 A Main or Branch Breaker
600–2500 A Main Lugs See Main Lug Compartments, 3Ø4W System, page 7.
Neutral Distribution Unitaf Neutral Rating 1250 A Max. 1446. 12 G
Solid Neutral Bus q (Price per section – 20 in. 600–800 A (1)1.5 in. x 0.25 in. cu 178.
0 D
deep sections required) 1200–2500 A (2) 1.5 in. x 0.25 in. cu; Max. 100% Rating is 1200 A per section
Neutral Bus Drop ak
(Provides vertical extension of solid neutral bus Provides vertical extension of solid neutral bus into vertical 612.
0
wireway to facilitate neutral connections from units. D
into vertical wireway to facilitate neutral per section
connections from units)
c Except for Compac™ 6 units.
t When >35 kA SCCR or electronic trip, additional 6 in. space required on top located mains and 3 in. space for bottom located mains and branches.
a Neutrals in units are factory-connected when the Neutral Distribution option or Neutral Bus Drop option are chosen.
f Neutral Distribution Units must go in next adjacent section on bottom feed full section mains. 12 in. additional space not required on top feed full section (72 in.) mains.
q Not available with Through-the-Back splice.
k 25 in. wide section required when used with a cabled main or branch breaker devices (450–600 A branches and 400–600 A mains). Neutral bus drop is not available in
sections with 800 A or larger top main or any branch breakers , or 600 A or larger top main or any branch switches. However, the 4-wire Neutral Lug Termination will be
factory-connected to the MCC neutral and additional holes are drilled for unit load neutrals on the main/branch neutral termination.

Four-Wire Examples
A
A Solid N Neutral Lug A
B Neutral B Termination B
C Bus C Assembly C
Neutral Drops
Disconnect Disconnect Disconnect

Neutral Lug Neutral Lug Cable


Termination Termination
Assembly Assembly Neutral
Distribution
Unit
Cable

Figure 1 Figure 2 Figure 3


Service Entrance Label (not available on Main Lug Systems)
Description Application Price Space (Inches) Shipping Code
3Ø3W System with a Main Breaker/Switch 15–2500 Aa N/C 0
110–150 A without GFI
3
110–150 A with GFI
175–250 A without GFI
175–250 A with GFI 0
300–400 A without GFI c
300–400 A with GFI t 12
3Ø4W System with a Main Breaker/Switch
NOTE: A Neutral Lug Termination option and/or 450–600 A circuit breaker without GFI 6
C
450–600 A circuit breaker with GFI $300. 12h
Solid Neutral Bus option is required on
4-wire systems. 800–2500 A circuit breaker with GFI a
0
600–2000A switch with GFI a
800 A circuit breaker without GFI
15
1200 A circuit breaker (80% rated) without GFI
600–800 A switch without GFI
12
1000–1200 A bottom incoming switch without GFI
Any other main without GFI (except as shown above) 0
a Ground Fault Protection is added to all 1000 A and larger mains when Service Entrance is specified and the system voltage is 480 V. The appropriate space, price, and
shipping code will be applied from the Ground Fault Option table on page 59.
c When SCCR is >35 kA on 300–400 A applications, additional space is required (top feed—15 in. and bottom feed—9 in.).
t 15 in. of additional space required for top feed applications.
h Requires 6 in. of additional space when metering option is selected.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 13
Incoming Devices

PowerLogic® Circuit Monitors


PowerLogic Circuit Monitors, CM4000 or CM3000, are a multifunction Ethernet communications. A 4-line x 20-character LCD type display with
digital metering and monitoring device capable of replacing a variety of customizable displays is provided as standard. An optional Vacuum
meters, relays, transducers, and other components. Data available for Fluorescent Display with backlighting is also available. The circuit
local viewing includes metered values plus extensive min/max, alarm, monitors offer waveform capture, event/alarm logging and custom
and analog/digital input data. Circuit Monitor data is available for viewing alarms. Prices listed include the CM, CT's, CT shorting terminal block,
and recording via standard RS-485, RS-232 (CM4000 only), or optional Current/Voltage module, voltage connections, and power supply.

Price Space Shipping


Description Application
(Type B-D Wiring) (Inches) Code

Monitors
CM3250 with LCD Display Circuit Monitor, data logging, waveform capture, 8 MB memory, LCD display $20000.
CM3350 with LCD Display Circuit Monitor, same features as CM3250 with disturbance monitoring 22000.

CM4250 with LCD Display Instrumentation, data logging, waveform and disturbance capture, programmable logic, 2 optional 25000.
card slots
See Table
CM4000T with LCD Display CM4000 features plus high-speed voltage transient detection and capture 35000. C
Below
Standard
CMDLC 4-line x 20 character liquid crystal display with backlighting
N/C
4-line x 20 character vacuum fluorescent display with I/R port and proximity sensor substituted for
CMDVF 2800.
standard LCD display

I/O Modules
2660. (Qty. 1)
IOC44 qf Field-installable I/O card with 4 status inputs, 3 relay (10 A) outputs, and 1 pulse output (KYZ)
5320. (Qty. 2)
IOX0404 c I/O extender module with 4 status inputs and 4 analog inputs (4–20 mA) 6300.
I/O extender module with 4 inputs (32 Vdc), 2 outputs (60 Vdc), 1 analog input (0–5 Vdc), 0 C
IOX2411 c 4900.
1 analog output (4–20 mA)
IOXO8 c I/O extender module with 8 status inputs (120 Vac) 2600.

IOX c I/O extender module only, no installed I/O, accepts up to 8 I/O modules with maximum of 2000.
4 analog I/O

Accessories
Ethernet communications card, 100 Mbps fiber and 10/100 Mbps modules with UTP Ethernet port
ECC21qf 6700. 0 C
and 1 RS-485 master port
q Only 1 slot is available for I/O Modules or the Ethernet ECC21 card on CM3000.
f 2 slots are available for (2) IOC44 I/O Modules or (1) IOC44 I/O Module and (1) Ethernet ECC21 card on CM4250/4000T.
c Available on CM4250/4000T only. Choose only 1 module per circuit monitor.

Circuit Monitor Space Requirements


Additional Space Requirements (Inches)
Device Type
Main Unit Monitor Unit c Total

Main Lugs
600–1200 A 12
0 12
1600–2500 A 12a

Main Circuit Breaker


110–250 A 6 18
300–400 A 9 21
450–600 A 6 18
12
800 A
15 27
1200 A 80% rated
1200 A 100% rated; 1600–2500 A 0 12a

Main Fusible Switch


200 A 6 18
Top Located, 400 A 3 15
Bottom Located, 400 A 6 18
600–800 A 12 12 24
Top Located, 1000–1200 A 0 12
Bottom Located, 1000–1200 A 12 24
1600–2000 A 0 12a
c The Circuit Monitor unit must be placed adjacent to (below, above, or next to) the Main unit .
a If no space is available for the circuit monitor, an option requiring no additional space for the circuit monitor module is available by integrating the metering equipment on
the door of a full section main.
NOTE: On bottom located mains, this option protrudes 6.2 in. out from the door and reduces the customer aisleway by the same dimension.

PE4 Discount Prices subject to change without notice.


14 Schedule 12/08
Incoming Devices

PowerLogic® Power Meter


The PowerLogic Series 800 Power Meter is a high-performance power monitoring component able to provide advanced power measurement
capabilities in a compact MCC plug-in starter. It is designed for use in basic power metering applications and can replace conventional metering devices
such as ammeters, voltmeters, and watt-hour meters while providing powerful capabilities not offered by analog metering. This option can offer an
economical advantage in MCCs requiring multiple analog meters for voltage, current, and watt-hours. Its easy-to-use, intuitive interface and self guiding
menus along with a large antiglare and back-lit display makes this meter the easiest to navigate and use.
• Monitor current, voltage, power, and energy simultaneously
• Individual harmonic measurements on current and voltage
• THD measurement
• Modbus® RS-485 Communications and compatible with Transparent Ready® Equipment
The Power Meter offering below is for MCC Incoming Main Devices only. The MCC Power Meter option includes the Power Meter Module, front
mounted display for easy viewing, main and control voltage fusing, and necessary current transformers with shorting terminal blocks in the main device.
Optional modules can be added to the Power Meter to increase type and number of inputs and outputs. For other Power Meter applications, contact
the MCC Technical Assistance Group.

Price Power Meter Space Requirements


(Type Space Shipping
Description Application System Additional Space
B-D (Inches) Code
Wiring) Requirements (Inches)
Device Type
Meters Main Meter
Unit Unit c Total
Power Meter door mounted 3Ø3W $ 8124.
display + Module with
Instrumentation Functions, Main Lugs
PM820 THD measurement, 3Ø4W 8424. 600–1200 A 0
alarming, and 80kb 6 6
logging. 1600–2500 A 0
C
Power Meter door mounted 3Ø3W 14122.
display + Module with Main Circuit Breaker
Instrumentation Functions,
PM850 See 110–250 A 6 12
THD measurement, 3Ø4W 14522. Table
alarming, 800kb logging, Below
and waveform capture. 300–400 A 9 15
Power Meter door mounted 3Ø3W 19122. 450–600 A 6 12
display + Module with 6
Instrumentation Functions, 800 A 15 21
PM870 THD measurement, F
alarming, 800kb logging, 1200 A 80% rated 15 21
3Ø4W 19522.
configurable waveform
capture, and sag/swell 1200 A 100% rated; 1600–2500 A 0 6
detection.
Main Fusible Switch
I/O Modules
Up to 2 modules of the same or different types can be mounted on the meter to 200 A 6 12
expand the I/O.
Top Located, 400 A 3 9
I/O Module with 2 digital
PM8M26 outputs (relays), 6 digital 2280. Bottom Located, 400 A 6 12
inputs
0 C 600–800 A 12 6 18
I/O Module with 2 digital
PM8M2222 outputs, 2 digital inputs, 2 2968. Top Located, 1000–1200 A 0 6
analog outputs and 2
analog inputs Bottom Located, 1000–1200 A 12 18
Accessories 1600–2000 A 0 6
Ethernet Communications c The Power Meter unit must be placed adjacent to (below, above, or next to) the
Card includes: Main unit.
instantaneous readings,
advance security, TRE
Level 1, Web browser
based Diagnostics and
Register Reader,
10/100BaseTx Ethernet,
PM8ECC RS-485, and support for 5200. 0 F
2-wire and 4-wire daisy
chains. Supported
protocols: Modbus TCP/IP,
FTP, SNMP MIB2, ARP,
UDP, and HTTP.

Available on all Power


Meter 800 Series meters.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 15
Incoming Devices

PowerLogic Power Meter and Circuit Monitor Comparison


Model Model Model Model Model Model Model
Feature
PM820 PM850 PM870 CM3250 CM3350 CM4250 CM4000T
Amps, Volts, Power, Energy, PF X X X X X X X
Communications: RS485 Modbus® X X X X X X X
Communications: Optional Ethernet X X X X X X X
Demand Readings, THD X X X X X X X
Trending and Forecasting X X X X
ITIC/SEMI F47/NEMA MG-1-1998 Optional Optional Optional Optional
Extended Memory X X
Alarm Event Log X X X X X X X
High Speed (100ms) Alarms X X X X X X
Disturbance (10ms) Alarms X X X
Transient (1 microsecond) Alarms X
Interval Min./Max./Avg. Log X X X X
Billing Log X X X
Waveform Capture X X X X X X
Disturbance Waveform Capture X X X X
100ms Event Recordings X X X
Infrared Port Optional Optional Optional Optional
Analog Inputs/Outputs (Maximum) (4) (4) (4) (0) (0) (4) (4)
Digital Inputs/Outputs (Maximum) (17) (17) (17) (8) (8) (24) (24)
Programmable Math and Logic Functions X X
Downloadable Firmware X X X X X X X

Metering Options–Total space of unit and meter options shall not exceed 72 in.
Metering Shipping
Description Application Price Space (Inches)
Sequence Code
110–250 A Main Circuit Breakers Hot 15
When used with Voltmeter 0
15–250 A Branch Circuit Breaker Cold 15
When used with Voltmeter 0
300–600 A Main/Branch Circuit Breakers Cold 9
When used with Voltmeter 0
$2222. D
800–2500 A Main/Branch Circuit Breakers Not available a
AC Ammeter with Transfer Switch and two Current 30–200 A Main/Branch Fusible Switches Cold 15
Transformers and Shorting Terminal Blocks
(Three CTs provided on 4-wire systems) When used with Voltmeter 0
400 A and above Main/Branch Fusible Switches Cold 9
When used with Voltmeter 0
600–2000 A Main/Branch Fusible Switches Not available a
600–1200 A Top Located Main Lugs Hot 9
When used with Voltmeter 2876.
F
600–1200 A Bottom Main Lugs Hot 0
1600–2000 A Main Lugs Hot 1980.
AC Voltmeter with VM Transfer Switch and two Main and Branch Feeders a Cold 3124. 9 D
Potential Transformers (Three PTs provided on
4-wire systems) Main Lugs Hot 3318. F
0
Elapsed Time Meters Starter Unit 480. C
AC Ammeter with Current Transformer Starter Unit 940. 3
1% Meters (Switchboard Type) Price as standard meters and add per meter 944. 6
Main Breaker/Switch only 2146. 12
Ground Detection Lights
Main Lugs 2338.
0 F
Fuse for Metering Circuit For special applications only 92.
Current Transformer (CT) For special applications only 300. 3
Potential Transformer (PT) For special applications only 750. 6
Shorting Terminal Blocks for Metering CTs Option for Starters, Branch Feeders (standard on PowerLogic devices) 166. 0
s Not available on Compac™ 6 starters.
a Analog metering is not available on PowerPact® M-, P-, and R-frame units. Use an optional Micrologic® ammeter, power, or harmonic trip unit on the circuit breaker, or a
PowerLogic circuit monitor/power meter for switch applications.

PE4 Discount Prices subject to change without notice.


16 Schedule 12/08
Incoming Devices

Transient Voltage Surge Suppressor Units for MCC Incoming Mains

General Information All Motor Control Center TVSS Units for MCC Incoming Mains include
as standard:
NOTE: TVSS units must be installed on grounded power distribution
systems. Installation on an ungrounded power distribution system must • Flange Mounted Disconnect
not be recommended or specified. See the figure below for proper • Door-mounted Diagnostic Lights for each phase
transformer feed to the MCC where TVSS units can be applied. • Audible Alarm with Test/Disable/Enable switch
• Must be located as close as possible to the incoming main provision. • TVSS with EMI/RFI Filter
• TVSS units for 4-wire systems must include a Solid Neutral Bus • UL 1449 Standard, Second Edition Tested and Recognized
and/or Neutral Lug Termination Assembly in the MCC. Component
• TVSS components for installation in MCC-mounted panelboards • UL 1283 Recognized Component
or on distribution transformer secondaries should use a • cUL certified component
panel-mounted TVSS component and should be priced by contacting • Motor Control Center certifications per UL 845, CSA (Canada), and
the MCC TAG in Seneca. NOM (Mexico)
• Individually fused suppression modules utilizing surge-rated fuses
• Each suppression MOV is thermally protected for low current faults
Transformer Secondary
• High energy parallel MOV design for Category A, B, C3 exposure
High Leg Delta levels per IEEE C62.41 criteria
Grounded Wye
B • Can be applied to MCCs with 100 kAIC Short Circuit Withstand rating
• Designed as standard MCC unit construction to enable new or retrofit
applications
or
• One Form C alarm contact
A C
N
Selection
1. Select the TVSS Model based on:
a. System voltage (e.g., 480 Vac, 240 Vac, 208 Vac, or 600 Vac)
b. Desired Surge Current Capacity (e.g.,120 kA, 160 kA, or
240 kA). If a Surge Current Capacity higher than 240 kA is
required, more than one TVSS unit can be priced and entered to
the MCC to add up to the desired Surge Current Capacity. When
entering more than one TVSS unit to an MCC, all units should be
mounted in the same section, if possible, and as close as
possible to the MCC incoming main unit.
c. Type of loads to be protected (e.g., branch loads, service
entrance applications, or large individual loads)
d. If backup redundancy is a requirement, two TVSS units should
be priced and entered in the same MCC section and in adjacent
mounting spaces.
2.Select the TVSS Model based on the main power transformer
connection as shown in the figure at left, desired Surge Current
Capacity, and type of loads to be protected.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 17
Incoming Devices

Model IMA TVSS (120 kA Surge Rating)


• For protection of small MCC lineups and non-critical loads
• 120,000 amperes per phase surge current capacity

Space Shipping
Customer Incoming Power Connection to MCC System Voltage Price
(inches) Code
208 Vac, 3 Phase E
3 Phases with or without neutral connected to MCC (3 or 4-wire MCC).
480 Vac, 3 Phase C
Wye Secondary Transformer with grounded neutral.
600 Vac, 3 Phase $12000. 6 E
Transformer with Hi-Leg Delta Secondary. 3 Phases with or without neutral connected to MCC (3 or 4-wire MCC).
240 Vac, 3 Phase F
NOTE: B-Phase is configured as the high leg.

Model IMA TVSS (160 kA Surge Rating)


• For protection of branch loads/electronics, large individual loads and drives/soft starts
• 160,000 amperes per phase surge current capacity

Space Shipping
Customer Incoming Power Connection to MCC System Voltage Price
(inches) Code
208 Vac, 3 Phase E
3 phases with or without neutral connected to MCC (3 or 4-wire MCC).
480 Vac, 3 Phase C
Wye secondary transformer with grounded neutral.
600 Vac, 3 Phase $16000. 6 E
Transformer with Hi-Leg Delta Secondary. 3 Phases with or without neutral connected to MCC (3 or 4-wire MCC).
NOTE: B-Phase is configured as the high leg. 240 Vac, 3 Phase F

Model IMA TVSS (240 kA Surge Rating)


• For application on High Exposure Systems for service entrance protection with large power electronic loads (drives/soft starts)
• 240,000 amperes per phase surge current capacity

Space Shipping
Customer Incoming Power Connection to MCC System Voltage Price
(inches) Code
208 Vac, 3 Phase E
3 Phases with or without neutral connected to MCC (3 or 4-wire MCC).
480 Vac, 3 Phase C
Wye Secondary Transformer with grounded neutral.
600 Vac, 3 Phase $23000. 6 E
Transformer with Hi-Leg Delta Secondary. 3 Phases with or without neutral connected to MCC (3 or 4-wire MCC).
240 Vac, 3 Phase F
NOTE: B-Phase is configured as the high leg.

Additional Options
Space Shipping
Description Price
(Inches) Code
Surge Counter—Door mounted display which counts the number of transients entering the facility through the suppressor $1250. 0 C

PE4 Discount Prices subject to change without notice.


18 Schedule 12/08
Branch Feeder Units

Circuit Breaker Branch Feeder Units


• Branch feeder units may be located in 20 in.wide by 15 in. or 20 in. deep sections, except where noted.
• Select Trip Rating and desired Unit Interrupting rating.
• All units are for 3Ø3W systems. For 3Ø4W applications see “3 Phase/4 Wire Systems” on page 13. Not available on Compac™ 6 units.
• 80% rated thermal-magnetic molded case circuit breakers are standard.
• 100% rated units can be selected below as an option.
• Shipping codes listed are for standard wire lug ranges, see “Main and Branch Circuit Breaker Lug Ranges” on page 12. Other wire range lugs are
available–shipping code F.
• Units are available with gray or white interiors without affecting the delivery listed below. Deduct $180. from list price below for gray units.

Thermal-Magnetic Molded Case Circuit Breakers


Breaker Unit Interrupting Rating (kA)
Breaker
Trip
Frame Breaker Type Price Space (Inches) Shipping Code
Rating 208/240 V 480 V 600 V
(Amps)
(Amps)
Standard (80%) Rated
65 35 18 $ 1480.
15–60 100 65 25 1780.
100 100 50 2250.
65 35 18 1550.
70–100 150 HG/HJ/HL 100 65 25 1880.
100 100 50 2600.
65 35 18 2670.
6
110–150 100 65 25 3470.
(Compac 6, Plug-on)
100 100 50 4800.
65 35 18 2910.
175–225 100 65 25 3800.
100 100 50 4900.
250 JG/JJ/JL
65 35 18 3500.
250 100 65 25 5800.
100 100 50 6350.
65 35 18 1380.
15–60 100 65 25 1680. B
100 100 50 2150.
65 35 18 1450.
12
70–100 150 100 65 25 1780.
HG/HJ/HL (Plug On)
100 100 50 2500.
65 35 18 2520.
110–150 100 65 25 3320.
100 100 50 4320.
65 35 18 2760.
175–225 100 65 25 3650.
100 100 50 4750. 18
250 JG/JJ/JL
65 35 18 3160. (Plug On)
250 100 65 25 4190.
100 100 50 5460.
400 LA 42 30 22 5300.
300–400 400 LH 65 35 25 6070. 27
(Plug On)
600 LI 100 100 100 7770.
450–600 600 LI 100 100 100 8280. 36k
800 MJ 65 65 25 10570. 18 (Top Entry)
800
1200 PL/PK 100 100 50 14000. 18q (25 W, Bottom Entry) C
21 (Top Entry)
1200 1200 PL/PK 100 100 50 15250.
21q (25 W, Bottom Entry)
Optional 100% Rated
NOTE: All 100% rated circuit breakers are molded case with Micrologic® electronic trip. LE electronic trip circuit breakers include Full Function Trip Unit with LSI tripping
functions. P and R-frame electronic trip circuit breakers include Basic 3.0 Trip Unit with LI tripping functions.
100–400 400 LE 100 65 35 12404. 36k
18 (Top Entry) F
600 1200 PL/PK 100 100 50 14000.
18q (25 W, Bottom Entry)
21 (Top Entry)
800 1200 PL/PK 100 100 50 15250.
21q (25 W, Bottom Entry)
C
72c (20 W x 20 D)
1200 1200 PL/PK 100 100 50 21250.
NEMA 1/1A only
k Specify top or bottom entry.
q Top located in section with 9 in. vertical wireway for bottom cable entry.
c Requires single shipping split.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 19
Branch Feeder Units

Fusible Switches Branch Feeder Units


• Branch feeder units may be located in 20 in. wide by 15 in. or 20 in. deep sections, except where noted.
• Branch feeder units up to 100 A use a bladed switch disconnect. Above 100 A, the disconnect is an automatic molded case switch.
• Class H (0–600 A) and Class L (800–1200 A) fuse clips are provided as standard, except Compac™ 6 (six-inch) units, which use Class J fuse clips.
Class R fuse clips can be provided at no additional charge for 30–600 A switches. See “Fusible Switch Options” on page 57.
• All fusible switch units have a unit short circuit rating of 100,000 A.
• Fuses are not included. To order factory installed fuses, see “Factory Installed Fuses” on page 57.
• All units are for 3Ø3W systems. For 3Ø4W applications, see “3 Phase/4 Wire Systems” on page 13. Not available on Compac™ 6 units.
• Shipping codes listed are for standard wire lug ranges, see ““Main and Branch Fusible Switch Lug Ranges” on page 12. Other wire range lugs are
available—shipping code F.
• Units are available with gray or white interiors without affecting the delivery listed below. Deduct $180. from list price below for gray units.

Branch Fusible Switches


Maximum Fuse Size
(Amps) Shipping
Price Space (Inches) Code
600 V Max.
30
$ 1222.
60 6t (Plug-on)
100 1696.
30
1110.
60 12 (Plug -on)
100 1542.
200 1910. 24 (Plug -on) B
400 4172. 51
60 (top exit)
600c 6428.
60 p (25 W, bottom exit)
60 (top exit)
800c 13670. 60 p (25 W, bottom exit)
1000c 16500.
72 k (20 W x 20 D)
1200c 20460.
t Compac 6 units.
c Specify top or bottom exit.
p Top located in section with 9 in. vertical wireway for bottom cable entry.
k Requires single shipping split.

SPECIAL NOTE
Only one 400 A or larger main disconnect, top located main lug, or
starter unit can be installed per section. Only one 450 A or larger cabled/
bussed branch can be installed per section.

PE4 Discount Prices subject to change without notice.


20 Schedule 12/08
Combination Starter Units with Circuit Breaker Disconnects

Full Voltage Non-Reversing (FVNR) Starters with Circuit Breakers


FVNR combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted.
All Compac™ 6 NEMA rated six-inch starters use GJL frame Mag-Gard® motor circuit protectors. All standard height starters with MCP frames through
250 A use PowerPact® electronic motor circuit protectors. All starters with MCP frames above 250 A use L- and P-frame Mag-Gard motor circuit
protectors. Thermal-magnetic circuit breakers may be substituted for motor circuit protectors on starter units. Deduct $160. from list price below for
thermal-magnetic circuit breakers. All units are UL listed.
Unit prices below include white interiors (except Compac™ 6 starters). Deduct $180. from list price below for units with gray interiors.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower MCP Frame Price Shipping


NEMA Size Space (Inches)
208V 240 V 480 V 600 V (Amps) Type A Type B-D Code
5 30
5 10 — 1 — $ 2150. 6t
7.5 50
5 10 10 30
7.5 1 $ 1862. 1978. 12
7.5 — — 50
— 15 30
10 10 25 25 2 50 2190. 2312. 12
15 — 100
— — 30 50
20 25 50 50 3 100 3412. 3668. 18 B
25 30 — 150
— — 60 100
40 40 75 100 4 150 5082. 5692. 21
50 100 — 250
50 60 125 150 250 42k
5 10762. 11212.
75 100 200 200 400 48
100 — 250 300 400 72
6 22690. 23018.
150 200 400 400 600 (20 W x 20 D)

t Compac 6 units.
k Space requirement is 48 in. when thermal-magnetic breaker option is chosen.

FVNR Vacuum Starters with Circuit Breakers


Vacuum contactor combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All vacuum starter units
with circuit breaker disconnects use PowerPact® electronic motor circuit protectors (MCPs), or use L-frame or PowerPact M- or P-frame thermal
magnetic (TM) circuit breakers. All units are UL listed. Unit prices below include white interiors. Deduct $180. from list price below for units with gray
interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower MCP Frame or Price


NEMA Size Space (Inches) Shipping Code
208 V 240 V 480 V 600 V TM Trip/Frame (Amps) Type A Type B-D
— — — 60 100 MCP
40 40 75 100 4 150 MCP N/A $10152. 21
— 50 100 — 250 MCP
50 — — 150 200/400 TM
— 60 125 — 225/400 TM
60 75 150 200 5 250/400 TM N/A 15852. 48
75 — — — 300/400 TM Gc
— 100 200 — 350/400 TM
— — — 250 600/800 TM
100 125 250 300 600/800 TM
125 150 300 400 72
6 600/800 TM N/A 27998.
(20 W x 20 D)
150 — 350 — 600/800 TM
— 200 400 — 800/800 TM
c For F delivery code, select Motor Logic® Overload Relay option. Adjust price to include corresponding SSOL relay price adder.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 21
Combination Starter Units with Circuit Breaker Disconnects

Application-Rated Compac™ 6 Starters —Non-Reversing with Circuit Breakers


All Compac 6 application-rated, six-inch starters use D-line contactors and GJ frame Mag-Gard® adjustable instantaneous trip breakers (UL Listed for
100K at 480 V.) Compac 6 application-rated, six-inch starters will mount in 20 in. wide by 15 in. or 20 in. deep sections. Select application-rated units
based on system voltage and motor full load amps.

Application-Rated Full Voltage Non-reversing Combination Starters—With Mag-Gard Circuit Breaker (480 V Max.)
Starter Ampacity Overload Relay C/B Price
Ampacity Range a Amps Type B-D Space (Inches) Shipping Code
208 V 240 V 480 V
1 1 1 0.63 to 1.0 3
1.6 1.6 1.6 1.0 to 1.6 3
2.1 2.1 2.1 1.6 to 2.1 3
2.5 2.5 2.5 2.1 to 2.5 7
4 4 4 2.5 to 4.0 7
4.8 4.8 4.8 4.0 to 4.8 7
$2106.
5.5 5.5 5.5 4.8 to 5.5 15
7 7 7 5.5 to 7.0 15
9 9 — 7.0 to 9.0
15
— — 7.6 7.0 to 7.6
— 9.6 — 9.0 to 9.6
15
11 — — 9.0 to 11
— — 9 7.6 to 9.0 15
— — 11 9.0 to 11.0 6 B
15
— 11 — 9.6 to 11.0
12 12 12 11 to 12.0 30 2150.
— — 14 12.0 to 14.0
30
17 17 — 12.0 to 17.5
22 22 — 17.5 to 22.0 30
— — 17 14 to 17 30
— — 21 17 to 21 30
23 23 — 22 to 23
50
— — 23 21 to 23
2518.
30 30 30 23 to 30 50
34 34 34 30 to 34 50
37 37 — 34 to 37 75
42 42 — 37 to 42 75
a Maximum overload relay ampacity when used on Compac 6 units.

PE4 Discount Prices subject to change without notice.


22 Schedule 12/08
Combination Starter Units with Circuit Breaker Disconnects

Full Voltage Reversing (FVR) Starters with Circuit Breakers


FVR combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All starters with MCP frames through
250 A use PowerPact® electronic motor circuit protectors. All starters with MCP frames above 250 A use L-frame Mag-Gard® motor circuit protectors.
All units are UL listed.
Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower MCP Frame Price


NEMA Size Space (Inches) Shipping Code
208 V 240 V 480 V 600 V (Amps) Type A Type B-D
5 5 10 10 30
1 $ 2500. $ 2622. 18
— 7.5 — — 50
— — — 15 30
10 10 25 25 2 50 3382. 3498. 18
B
— 15 — — 100
— — — 30 50
20 25 50 50 3 100 4602. 4864. 27
25 30 — — 150
— — — 60 100
40 40 75 100 4 150 8182. 8622. 33 D
— 50 100 — 250
75 100 200 200 5 400 15846. 16282. 72 (25 W) F

FVR Vacuum Starters with Circuit Breakers


Vacuum contactor combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All vacuum starter units
with circuit breaker disconnects use PowerPact® electronic motor circuit protectors (MCP) or L-frame thermal magnetic (TM) circuit breakers as
indicated and are UL listed. Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor Control Center
unit short circuit ratings to 100,000 A are available.

Starter Horsepower MCP Frame or Price


NEMA Size TM Trip/Frame Space (Inches) Shipping Code
208 V 240 V 480 V 600 V (Amps) Type A Type B-D
— — 100 MCP
40 40 75 100 4 150 MCP N/A $17022. 21
50 100 250A MCP
50 — — 150 200/400 TM
G
— 60 125 — 225/400 TM
60 75 150 200 5 250/400 TM N/A 25322. 48
75 — — — 300/400 TM
— 100 200 — 350/400 TM

Application-Rated Compac™ 6 Starters—Reversing with Circuit Breakers


All Compac 6 application-rated, six-inch starters use D-line contactors and GJ frame Mag-Gard adjustable instantaneous trip breakers (UL Listed for
100K at 480 V.) Compac 6 application-rated, six-inch starters will mount in 20 in. wide by 15 in. or 20 in. deep sections. Select application-rated units
based on system voltage and motor full load amps.

Application-Rated Full Voltage Reversing Combination Starters – With Mag-Gard® Circuit Breaker (480 V Max.)
Starter Ampacity Overload Relay Price
C/B Amps Space (Inches) Shipping Code
208 V 240 V 480 V Ampacity Range a Type B-D
1 1 1 0.63 to 1.0
1.6 1.6 1.6 1.0 to 1.6 3
2.1 2.1 2.1 1.6 to 2.1
2.5 2.5 2.5 2.5 to 4.0
4 4 4 2.5 to 4.0 7
4.8 4.8 4.8 4.0 to 4.8 $2814.
5.5 5.5 5.5 4.8 to 5.5
7 7 7 5.5 to 7.0
— — 7.6 7.0 to 7.6
9 9 — 7.0 to 9.0 6 B
— 9.6 — 9.0 to 9.6 15
11 — — 9.0 to 11
— — 9 7.6 to 9.0
— — 11 9.0 to 11.0
— 11 — 9.6 to 11
2858.
12 12 12 11.0 to 12.0
— — 14 12.0 to 14.0
30
17 17 — 12.0 to 17.5
22 22 — 17.5 to 22.0
a Maximum overload relay ampacity when used on Compac 6 starters.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 23
Combination Starter Units with Circuit Breaker Disconnects

Reduced Voltage Autotransformer (RVAT) Starters with Circuit Breakers


RVAT combination starters mount in standard 20 in. wide by 20 in. deep sections. Sections with RVAT starters require single shipping splits. All RVAT
starter units with circuit breaker disconnects use thermal-magnetic (TM) circuit breakers. All units are UL listed.
For thermal cutout autotransformer starters, add $606. to the list prices below and extend shipping code to F.
Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower TM Trip/Frame Price


NEMA Size Space (Inches) Shipping Code
208 V 240 V 480 V 600 V (Amps) Type A Type B-D
— — — 30 80/150
— — 30 — 100/150
48
— — — 40 3 110/150 $ 9345. $ 9773.
(20 deep)
15 — — — 125/150
20 25 50 50 150/150
— — — 60 175/250
25 30 60 75 4 200/250 15359. 15980. 60
(20 deep)
40 50 100 100 250/250
50 — — 150 200/400 B (480 V)
60 125 — 225/400
D
72 (other voltages)
60 75 150 200 5 250/400 29132. 29753.
(25 W x 20 D)
75 — — — 300/400
— 100 200 — 350/400
— — — 250 600/800
100 125 250 300 600/800
— — — 350 600/800 72
6 — 69858.
125 150 300 400 600/800 (30 W x 20 D)

150 — 350 — 600/800


— 200 400 — 800/800

PE4 Discount Prices subject to change without notice.


24 Schedule 12/08
Combination Starter Units with Circuit Breaker Disconnects

RVAT Vacuum Starters with Circuit Breakers


RVAT combination starters mount in standard 20 in. wide by 20 in. deep sections. Sections with RVAT starters require single shipping splits. All RVAT
starter units with circuit breaker disconnects use thermal magnetic (TM) circuit breakers. All units are UL listed. For thermal cutout autotransformer
starters, add $606. to the list prices below. Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor
Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower TM Trip/Frame Price


NEMA Size Space (Inches) Shipping Code
208 V 240 V 480 V 600 V (Amps) Type A Type B-D
— — — 60 175/250
25 30 60 75 60
4 200/250 — $ 31712.
(20 D)
30–40 40–50 75–100 100 250/250
50 — — 125–150 200/400
— 60 125 — 225/400
72
60 75 150 200 5 250/400 — 46312.
(25 W x 20 D)
75 — — — 300/400
G
— 100 200 — 350/400
— — — 250 600/800
100 125 250 300 600/800
— — — 350 600/800 72
6 — 84762.
125 150 300 400 600/800 (30 W x 20 D)

150 — 350 — 600/800


— 200 400 — 800/800

Full Voltage Two-step Part-winding (FVPW) Starters with Circuit Breakers


Part-winding combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. Part-winding starters use a
separate motor circuit protector (MCP) for each of the two motor windings. All starters with MCP frames through 250 A use PowerPact® electronic motor
circuit protectors. All starters with MCP frames above 250 A use L-frame Mag-Gard® motor circuit protectors. All units are UL listed.
Each MCP has an external operating mechanism. Part-winding starters require six thermal units. Unit prices below include white interiors. Deduct $180.
from list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower MCP Frame Price Shipping


NEMA Size (Amps) Space (Inches) Code
208 V 240 V 480 V 600 V Type A Type B-D
5 5 10 15 30
1 $ 4233. $ 4473. 30
10 10 15 — 50
— — 25 25 50
2 5923. 6132. 30 F
20 25 40 40 100
— — 50 60 100
3 8592. 8822. 36
40 50 75 75 150
— — — 100 150
4 15492. 15760. 54
75 75 150 150 250 G
150 150 350 350 5 400 31495. 31879. 72 (25 W X 20 D)

Prices subject to change without notice. PE4 Discount


12/08 Schedule 25
Combination Starter Units with Circuit Breaker Disconnects

Full Voltage Two-speed 1-winding Starters (Consequent Pole) with Circuit Breakers
Two-speed combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All starters with MCP frames
through 250 A use PowerPact® electronic motor circuit protectors. All starters with MCP frames above 250 A use L-frame Mag-Gard® motor circuit
protectors. All units are UL listed. Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors.
Prices shown apply only when motor windings are Wye connected. Consult factory when windings are connected in Open Delta.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


MCP
NEMA Space Shipping
Constant Horsepower Constant Or Variable Torque Frame
Size Type A Type B-D (Inches) Code
(Amps)
208 V 240 V 480 V 600 V 208 V 240 V 480 V 600 V
5 5 7.5 7.5 5 7.5 10 10 1 30 $ 3570. $ 3692. 21
— — 10 15 — — — 15 30
7.5 10 20 20 10 10 25 25 2 50 5382. 5498. 24
— — — — — 15 — — 100 B
10 — 25 30 — — — 30 50
20 25 40 40 20 25 50 50 3 100 6766. 7038. 51q
— — — — 25 30 — — 150
— — 50 60 — — — 60 100
30 40 75 75 40 40 75 100 4 150 13194. 13634. 60
F
— — — — — 50 100 — 250
60 75 150 150 75 100 200 200 5 400 26840. 27588. 72 (25 W)
q When ambient compensated bimetal overload used, 60 in. of mounting space is required.

Full Voltage Two-speed 2-winding Starters (Separate Winding) with Circuit Breakers
Two-speed combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All starters with MCP frames
through 250 A use PowerPact electronic motor circuit protectors. All starters with MCP frames above 250 A use L-frame Mag-Gard motor circuit
protectors. All units are UL listed. Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor Control
Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA MCP Space Shipping
Constant Horsepower Constant Or Variable Torque Frame
Size (Amps) Type A Type B-D (Inches) Code
208 V 240 V 480 V 600 V 208 V 240 V 480 V 600 V
5 5 7.5 7.5 5 7.5 10 10 1 30 $ 2970. $ 3092. 21
— — 10 5 — — — 15 30
7.5 10 20 20 10 10 25 25 2 50 4172. 4292. 24
— — — — — 15 — — 100 B
10 — 25 30 — — — 30 50
20 25 40 40 20 25 50 50 3 100 5948. 6214. 30
— — — — 25 30 — — 150
— — 50 60 — — — 60 100
30 40 75 75 40 40 75 100 4 150 10850. 11290. 33
F
— — — — — 50 100 — 250
60 75 150 150 75 100 200 200 5 400 21876. 22746. 72 (25 W)

Full Voltage 2-speed Reversing Starters with Circuit Breakers


This chart lists the option to provide reversing contactors and control to a standard 2-speed starter. To price a 2-speed reversing starter, enter the
appropriate 2-speed starter (circuit breaker or fusible switch; one or two winding; constant horsepower or constant or variable torque) into the Quote To
Cash Product Selector. Enter the Application Type and the Price adder for the 2-speed reversing starter as shown below into the Special Pricing feature
of the 2-speed starter. The reversing contactors will be the same NEMA size as the 2-speed starter contactor. The control Circuit/Control Circuit
Transformer should be sized for the additional contactor load.

Add Reversing To 2-speed Starter


2-Speed Price Space Shipping
Application Type
Starter Size Adder (Inches) Code
1 $ 2302. 12
Reversing in Both Speeds 2 3782. 12
Reversing in Low Speed Only G
Reversing in High Speed Only 3 5358. 18
4 11112. 24

PE4 Discount Prices subject to change without notice.


26 Schedule 12/08
Combination Starter Units with Circuit Breaker Disconnects

Wye-Delta Closed Transition Starters with Circuit Breakers (Non-UL Listed)


Enter into Quote-To-Cash as a USER DEFINED DEVICE (see page 2).
Wye-Delta Closed Transition combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All Wye-Delta
starter units with circuit breaker disconnects use thermal magnetic (TM) circuit breakers. Unit prices below include white interiors. Deduct $180. from
list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower c TM Trip/Frame Price Shipping


NEMA Size Space (Inches) q
208 V 240 V 480 V 600 V (Amps) Type B-D Code

1.5 2 5 5 15/150
2 3 7.5 7.5 20/150
3 5 10 10 30/150
5 — 15 15 1 40/150 $ 9557. 60
— 7.5 — — 50/150
7.5 10 — — 60/150
10 — — — 70/150
— — — 20 40/150
— — 20 30 60/150
— — 25 — 2 70/150 12845. 66
15 15 30 40 90/150
20 25 40 — 100/150
— — 50 50 100/150
25 — — — 110/150
30 75 75 125/150
3 19826. 72 (30 W)
30 40 — — 150/150
40 — — — 175/250
H
— 50 — — 200/250
— — — 100 150/150
— — 100 — 175/250
50 — — 150 4 225/250 33041. Two full sections required
2 @ (20 W x 20 D)
— 75 150 — 250/250
60 — — — 300/400
— — — 250 300/400
75 100 250 300 350/400
Two full sections required
— 125 — — 5 400/400 48715. 1 @ (20 W x 20 D)
1 @ (30 W x 20 D)
125 150 300 — 500/800
150 — — — 600/800
— — — 350 500/800 Three full sections required
2 @ (20 W x 20 D)
— — 350 400 600/800 1 @ (30 W x 20 D)
— 200 400 500 700/800
6 93233. Three full sections required
200 250 500 600 800/800 1 @ (20 W x 20 D)
250 300 — 700 900/1200 1 @ (25 W x 20 D)
1 @ (30 W x 20 D)
300 350 600 — 1000/1200
c Wye-Delta starter motor information sheet required with each Wye-Delta starter.
q Space requirements listed are for resistor banks that meet standard Wye-Delta starting characteristics. Additional space may be required for other Wye-Delta applications.
Contact the MCC TAG for layout and pricing information.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 27
Combination Starter Units with Circuit Breaker Disconnects

Wye-Delta Open Transition Starters with Circuit Breakers (Non-UL Listed)


Enter into Quote-To-Cash as a USER DEFINED DEVICE (see page 2).
Wye-Delta Open Transition combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All Wye-Delta
starter units with circuit breaker disconnects use thermal magnetic (TM) circuit breakers. Unit prices below include white interiors. Deduct $180. from
list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower c TM Trip/Frame Price Shipping


NEMA Size Space (Inches) q
208 V 240 V 480 V 600 V (Amps) Type B-D Code

1.5 2 5 5 15/150
2 3 7.5 7.5 20/150
3 5 10 10 30/150
5 — 15 15 1 40/150 $ 8143. 24
— 7.5 — — 50/150
7.5 10 — — 60/150
10 — — — 70/150
— — — 20 40/150
— — 20 30 60/150
— — 25 — 2 70/150 9017. 30
15 15 30 40 90/150
20 25 40 — 100/150
— — 50 50 100/150
25 — — — 110/150
— 30 75 75 125/150
3 12818. 42
30 40 — — 150/150
40 — — — 175/250
H
— 50 — — 200/250
— — — 100 150/150
— — 100 — 175/250
50 — — 150 4 225/250 21041. 72 (20 W)
— 75 150 — 250/250
60 — — — 300/400
— — — 250 300/400
75 100 250 300 350/400
— 125 — — 5 400/400 38941. 72 (30 W)
125 150 300 — 500/800
150 — — — 600/800
— — — 350 500/800 Two full sections required
1 @ (20 W x 20 D)
— — 350 400 600/800 1 @ (30 W x 20 D)
200 400 500 700/800
6 73181.
200 250 500 600 800/800 Two full sections required
1 @ (25 W x 20 D)
250 300 — 700 900/1200 1 @ (30 W x 20 D)
300 350 600 — 1000/1200
c Wye-Delta starter motor information sheet required with each Wye-Delta starter.
q Space requirements listed are for resistor banks that meet standard Wye-Delta starting characteristics. Additional space may be required for other Wye-Delta applications.
Contact the MCC TAG for layout and pricing information.

PE4 Discount Prices subject to change without notice.


28 Schedule 12/08
Combination Starter Units with Fusible Switch Disconnects

Full Voltage Non-reversing (FVNR) Starters with Fusible Switch Disconnects


FVNR combination starters will mount in 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All FVNR starter units with fusible switch
disconnects are provided with Class H fuse clips. Class R fuse clips can be provided at no additional charge. Fusible disconnect combination starters
Sizes 5 and 6 use molded case automatic circuit interrupters in series with fuse clips.
All Compac™ 6 NEMA rated six-inch starters use Class J fuses (rated for 100,000 AIR at 600 volts). Compac 6 starters will mount in 20 in. wide by
15 in. or 20 in. deep sections.
Unit prices below include white interiors (except Compac 6 starters). Deduct $180. from list price below for units with gray interiors.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA Size F/S (Amps) Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Type A Type B-D
5 5 10 10 30
1 — $ 1782. 6t
7.5k 7.5 — — 60
5 5 10 10 30
1 $ 1498. 1620. 12
7.5k 7.5 — — 60
B
10 15 25 25 2 60 1920. 2040. 12 (480 V and 600 V)
20 25 50 50 100 18 C
3 2868. 3130. (208 V and 240 V)
25 30 — — 200 30
40 50 100 100 4 200 4950. 5392. 30
75 100 200 200 5 400 9168. 9614. 72
150 200 400 400 6 600 22530. 22858. 72 (30 W X 20 D)
k 5 hp maximum with solid state overload relays.
t Compac 6 starters.

FVNR Vacuum Starters with Fusible Switch Disconnects


Vacuum combination starters will mount in 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All FVNR Vacuum starter units with fusible
disconnects are provided with Class J fuse clips. Fusible disconnect combination starters Sizes 5 and 6 use molded case automatic circuit interrupters
in series with fuse clips. Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor Control Center
unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA Size F/S (Amps) Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Type A Type B-D
40 50 100 100 4 200 N/A $ 9852. 30
75 100 200 200 5 400 N/A 15314. 72 Gc
150 200 400 400 6 600 N/A 27998. 72 (30 W x 20 D)
c For F delivery code, select Motor Logic® Overload Relay option. Adjust price to include corresponding SSOL relay price adder.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 29
Combination Starter Units with Fusible Switch Disconnects

Application-Rated Compac™ 6 Starters—Non-Reversing with Fusible Switch Disconnects


All Compac 6 application-rated, six-inch starters use D-line contactors and Class J fuses (rated for 100,000 AIR at 600 V.) Compac 6 application-rated
six-inch starters will mount in 20 in. wide by 15 in. or 20 in. deep sections. Select application-rated starters based on system voltage and motor full load
amps.

Application-rated Full Voltage Non-reversing Combination Starters – With Fusible Disconnect (600 V Max. – Class J Only)
Starter Ampacity Overload Relay
F/S Amps Price Type B-D Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Ampacity Range a
1 1 1 1 0.63 to 1.0
1.6 1.6 1.6 1.6 1.0 to 1.6
2.5 2.5 2.5 2.5 1.6 to 2.5
4 4 4 4 2.5 to 4.0
5.5 5.5 5.5 5.5 4.0 to 5.5
30 $1738.
7 7 7 6.1 5.5 to 7.0
— — 7.6 — 7.0 to 7.6
9 9 .. — 7.0 to 9.0
— 9.6 — — 9.0 to 9.6
11 — — — 9.0 to 11
— — — 7 6.1 to 7.0
— — — 9 7.0 to 9.0
— — 9 — 7.6 to 9.0
— — — 11 9.0 to 11
— — 12 — 9.0 to 12 30
1782. 6 B
— 12 — — 9.6 to 12
12 — — — 11 to 12
— — 14 — 12 to 14
17 17 — — 12 to 17.5
22 22 — — 17.5 to 22 60
— — — 12 11 to 12
— — — 17 12 to 17
— — 17 — 14 to 17
— — 23 23 17 to 23
23 23 — — 22 to 23
60 2244.
— — — 27 23 to 27
30 30 30 23 to 30
— — 34 — 30 to 34
37 37 — — 30 to 37
42 42 — — 37 to 42
a Maximum overload relay ampacity range when used in Compac 6 starters.

Full Voltage Reversing (FVR) Starters with Fusible Switch Disconnects


FVR combination starters will mount in 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All FVR starter units with fusible switch
disconnects are provided with Class H fuse clips. Class R fuse clips can be provided at no additional charge. Fusible disconnect combination starter
Sizes 5 and 6 use molded case automatic circuit interrupters in series with fuse clips. All units are UL listed.
Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA Size F/S (Amps) Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Type A Type B-D
5 5 10 10 30
1 $ 2238. $ 2360.
7.5 7.5 — — 60 18
B
10 15 25 25 2 60 3392. 3498.
20 25 50 50 3 100 4980. 5246. 27
40 50 100 100 4 200 8714. 9154. 39 D
75 100 200 200 5 400 13628. 14070. 72 (25 W) F
k 5 hp maximum with solid state overload relays.

PE4 Discount Prices subject to change without notice.


30 Schedule 12/08
Combination Starter Units with Fusible Switch Disconnects

FVR Vacuum Starters with Fusible Switch Disconnects


Vacuum combination starters will mount in 20 in. wide by 15 in. or 20 in. deep sections. All vacuum starter units with fusible disconnects are provided
with Class J fuse clips. These starters use molded case automatic circuit interrupters in series with fuse clips. Unit prices below include white interiors.
Deduct $180. from list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA Size F/S (Amps) Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Type A Type B-D
40 50 100 100 4 200 N/A $17554. 39
G
75 100 200 200 5 400 N/A 23270. 72 (25W)

Application-Rated Compac™ 6 Starters—Full Voltage Reversing with Fusible Switch Disconnects


All Compac 6 application-rated, six-inch starters with fusible switch disconnects use D-line contactors and Class J fuses (rated for 100,000 AIR at
600 V.) Compac 6 application-rated, six-inch starters will mount in 20 in. wide by 15 in. or 20 in. deep sections. Select application-rated units based on
system voltage and motor full load amps.

Application-rated Full Voltage Reversing Combination Starters – With Fusible Disconnect (600 V Max. – Class J Only)
Starter Ampacity Overload Relay
F/S Amps Price Type B-D Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Ampacity Range a

1 1 1 1 0.63 to 1.0
1.6 1.6 1.6 1.6 1.0 to 1.6
2.5 2.5 2.5 2.5 1.6 to 2.5
4 4 4 4 2.5 to 4.0
5.5 5.5 5.5 5.5 4.0 to 5.5
— — — 6.1 5.5 to 6.1 30 $2552.
7 7 7 — 5.5 to 7.0
— — 7.6 — 7.0 to 7.6
9 9 — — 7.0 to 9.0
— 9.6 — — 9.0 to 9.6
11 — — — 9.0 to 11 6 B
— — — 7 6.1 to 7.0
— — — 9 7.0 to 9.0
— — 9 — 7.6 to 9.0
— — — 11 9.0 to 11
— — 12 — 9.0 to 12 30
2596.
— 12 — — 9.6 to 12
12 — — — 11 to 12
— — 14 — 12 to 14
17 17 — — 12 to 17.5
22 22 — — 17.5 to 22 60
a Maximum overload relay ampacity range when used in Compac 6 starters.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 31
Combination Starter Units with Fusible Switch Disconnects

Reduced Voltage Autotransformer (RVAT) Starters with Fusible Switch Disconnects


RVAT combination starters will mount in 20 in. wide by 15 in. or 20 in. deep sections, except where noted. Sections with RVAT starters require single
shipping splits. All RVAT starter units with fusible disconnects are provided with Class H fuse clips. Class R fuse clips can be provided at no additional
charge. Fusible disconnect combination starters Sizes 5 and 6 use molded case automatic circuit interrupters in series with fuse clips. For thermal cutout
autotransformer starters, add $606. to the list prices below and extend shipping code to F.
Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors.
Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA Size F/S (Amps) Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Type A Type B-D
20 25 50 50 3 100 $ 9972. $ 10342. 54 (20D)
40 50 100 100 4 200 17466. 18039. 72 (20D) B (480V)
75 100 200 200 5 400 26833. 27442. 72 (25W X 20D) D (Other Voltages)
150 200 400 400 6 600 — 69684. 72 (50W x 20D)

RVAT Vacuum Starters with Fusible Switch Disconnects


Sections with RVAT starters require single shipping splits. Provided with Class J fuse clips. Fusible disconnect combination starters Sizes 5 and 6 use
molded case automatic circuit interrupters in series with fuse clips.
All units are UL listed. For thermal cutout autotransformer starters, add $606. to the list prices below. Unit prices below include white interiors. Deduct
$180. from list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price Shipping


NEMA Size F/S (Amps) Space (Inches)
208 V 240 V 480 V 600 V Type A Type B-D Code

40 50 100 100 4 200 N/A $ 33736. 72 (20D)


75 100 200 200 5 400 N/A 44692. 72 (25W X 20D) G
150 200 400 400 6 600 N/A 84588. 72 (50W x 20D)

Full Voltage Two-step Part-winding (FVPW) Starters with Fusible Switch Disconnects
Part-winding starters use a fusible disconnect with separate fuse clips for each of the two motor windings. All units are UL listed. Each switch has an
external operating mechanism. Part-winding starters require 6 thermal units. Unit prices below include white interiors. Deduct $180. from list price below
for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA Size F/S (Amps) Space (Inches) Shipping Code
208 V 240 V 480 V 600 V Type A Type B-D
5 5 10 15 1 30 $ 4320. $ 4483. 30
— — 25 25 2 60 5748. 5940. 30 F
— — 50 60 3 100 7898. 8189. 42
— — — 100 4 200 14347. 14779. 66
G
150 150 350 350 5 400 29530. 30101. 72 (25W)

PE4 Discount Prices subject to change without notice.


32 Schedule 12/08
Combination Starter Units with Fusible Switch Disconnects

Full Voltage Two-speed 1-winding Starters (Consequent Pole) with Fusible Switch Disconnects
Two-speed combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. All units are UL listed. Unit
prices below include white interiors. Deduct $180. from list price below for units with gray interiors.
Prices shown apply only when motor windings are Wye connected. Consult factory when windings are connected in Open Delta. Motor Control Center
unit short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA F/S Space Shipping
Constant Horsepower Constant Or Variable Torque
Size (Amps) Type A Type B-D (Inches) Code
208 V 240 V 480 V 600 V 208 V 240 V 480 V 600 V
5 5 7.5 7.5 5 5 10 10 30
1 $ 3232. $ 3338. 21
— — — — 7.5 7.5 — — 60 B
7.5 10 20 20 10 15 25 25 2 60 4912. 5018. 24
20 25 40 40 25 30 50 50 3 100 6482. 6748. 51q
30 40 75 75 40 50 100 100 4 200 12162. 12602. 66 F
60 75 150 150 75 100 200 200 5 400 24872. 25628. 72 (25W)
q When ambient compensated bimetal overload used, 60 in. of mounting space is required.

Full Voltage Two-speed 2-winding Starters (Separate Winding) with Fusible Switch Disconnects
Two-speed combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted.
All units are UL listed. Unit prices below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor Control Center unit
short circuit ratings to 100,000 A are available.

Starter Horsepower Price


NEMA F/S Space Shipping
Constant Horsepower Constant Or Variable Torque Size (Amps) Type A Type B-D (Inches) Code
208 V 240 V 480 V 600 V 208 V 240 V 480 V 600 V
15 15 7.5 7.5 5 5 10 10 30
1 $ 2698. $ 2820. 21
— — — — 7.5 7.5 — — 60
B
7.5 10 20 20 10 15 25 25 2 60 3682. 3788. 24
20 25 40 40 25 30 50 50 3 100 5658. 5924. 30
30 40 75 75 40 50 100 100 4 200 10534. 10976. 39
F
60 75 150 150 75 100 200 200 5 400 21394. 22268. 72 (25W)

Full Voltage 2-speed Reversing Starters with Fusible Switch Disconnects


This chart lists the option to provide reversing contactors and control to a standard 2-Speed starter. To price a 2-Speed reversing starter, enter the
appropriate 2-Speed Starter (Circuit breaker or fusible switch; one or two winding; constant horsepower or constant or variable torque) into the Quote
To Cash Product Selector. Enter the Application Type and the Price adder for the 2-Speed Reversing Starter as shown below into the Special Pricing
feature of the 2-Speed Starter. The reversing contactors will be the same NEMA Size as the 2-Speed Starter Contactor. The control Circuit/Control
Circuit Transformer should be sized for the additional contactor load.

Add Reversing To 2-speed Starter


2-Speed
Price Space Shipping
Application Type Starter
Adder (Inches) Code
Size
1 $ 2302. 12
Reversing in Both Speeds 2 3782. 12
Reversing in Low Speed Only G
Reversing in High Speed Only 3 5358. 18
4 11112. 24

Prices subject to change without notice. PE4 Discount


12/08 Schedule 33
Combination Starter Units with Fusible Switch Disconnects

Wye-Delta Closed Transition Starters with Fusible Switch Disconnects (Non-UL Listed)
Enter into Quote-To-Cash as a USER DEFINED DEVICE (see page 2).
Wye-Delta Closed Transition combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. Unit prices
below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A
are available.

Starter Horsepower c
NEMA Size F/S (Amps) Price Type B-D Space (Inches) q Shipping Code
208 V 240 V 480 V 600 V
10 10 15 15 1 60 $ 9557. 60
20 25 40 40 2 100 12845. 66
40 50 75 75 3 200 17282. 72 (30 W)
Two full sections required
60 75 150 150 4 400 32366. 1 @ (25 W x 20 D)
1 @ (30 W x 20 D) H
Three full sections required
150 150 300 300 5 600 51374. 2 @ (25 W x 20 D)
1 @ (30 W x 20 D)
Three full sections required
300 350 600 700 6 800 96730. 2 @ (25 W x 20 D)
1 @ (35 W x 20 D)
c Wye-Delta starter motor information sheet required with each Wye-Delta starter.
q Space requirements listed are for resistor banks that meet standard Wye-Delta starting characteristics. Additional space may be required for other Wye-Delta applications.
Contact the MCC TAG for layout and pricing information.

Wye-Delta Open Transition Starters with Fusible Switch Disconnects (Non-UL Listed)
Enter into Quote-To-Cash as a USER DEFINED DEVICE (see page 2).
Wye-Delta Open Transition combination starters will mount in standard 20 in. wide by 15 in. or 20 in. deep sections, except where noted. Unit prices
below include white interiors. Deduct $180. from list price below for units with gray interiors. Motor Control Center unit short circuit ratings to 100,000 A
are available.

Starter Horsepower c Shipping


NEMA Size F/S (Amps) Price Type B-D Space (Inches) q
208 V 240 V 480 V 600 V Code

10 10 15 15 1 60 $ 8146. 30
20 25 40 40 2 100 9017. 42
40 50 75 75 3 200 12818.
72 (20 W)
60 75 150 150 4 400 21041. H
150 150 300 300 5 600 38941. 72 (30 W)
Two full sections required
300 350 600 700 6 800 73181. 1 @ (25 W x 20 D)
1 @ (30 W x 20 D)
c Wye-Delta starter motor information sheet required with each Wye-Delta starter.
q Space requirements listed are for resistor banks that meet standard Wye-Delta starting characteristics. Additional space may be required for other Wye-Delta applications.
Contact the MCC TAG for layout and pricing information.

PE4 Discount Prices subject to change without notice.


34 Schedule 12/08
AC Drives

Altivar® 61 and 71 AC Drives


General Information MCC Package Features
The Altivar 61 and 71 AC Drives in Motor Control Centers offers an As standard, basic MCC Altivar 61 and 71 AC Drive units include:
economical, general purpose drive in a high density, space saving • Altivar 61 or 71 AC Drive
package. Units are available in NEMA Type 1, Type 1 with Gaskets, • Operator keypad display mounted on the front of the unit
Type 12, and Type 3R Outdoor rated MCC enclosures in the following • Disconnect circuit breaker or fusible switch
ranges: • 3% line reactors above 50 hp VT or 40 hp CT @ 480V and above
25 hp VT or 20 hp CT @ 240V and above 20 hp VT/CT @ 208V
NEMA 1 and 1 Gasketed Enclosures • Cooling fans
Motor Ratings
Altivar 61 Variable Altivar 71 Constant • UL 845 listed for 100,000 AIC short circuit withstand at 480Vac.
Torque Rated Torque Rated
• Control station plate with space for five (5) 22mm operators or (3)
460 Vac, 3 Phase, 60Hz 1–500 hp 1–450 hp 30mm (9001Type K) operators.
230 Vac, 3 Phase, 60Hz 1–50 hp 1–40 hp MCC Altivar AC Drive units are plug-on style saddles (up to 50 hp
Variable Torque) or full sections which can be factory/field-installed in
200 Vac, 3 Phase, 60Hz 1–40 hp 1–40 hp
Model 6 MCCs or field-installed in Model 5 MCCs. There are no
NEMA 12 Enclosures preferred or restricted locations for mounting any Altivar AC Drive in
Altivar 61 Variable Altivar 71 Constant Square D® brand MCC sections.
Motor Ratings
Torque Rated Torque Rated
Circuit breakers used on the MCC Altivar AC Drive basic units are
460 Vac, 3 Phase, 60Hz 1–100 hp 1–75 hp thermal-magnetic type. As an option, PowerPact® electronic motor
230 Vac, 3 Phase, 60Hz 1–50 hp 1–40 hp circuit protectors can be substituted for the thermal-magnetic circuit
breakers up to 250 amps. Fusible switches used on the MCC Altivar AC
200 Vac, 3 Phase, 60Hz 1–40 hp 1–40 hp
Drive units are bladed switches (molded case switches above 100 A)
NEMA 3R Enclosures with Class J fuse clips installed between the drive and the switch.

Motor Ratings
Altivar 61 Variable Altivar 71 Constant NOTE: Fusible disconnect drives do not include the power fuses
Torque Rated Torque Rated installed at the factory.
460 Vac, 3 Phase, 60Hz 1–40 hp
Factory Options
230 Vac, 3 Phase, 60Hz Use Constant Torque 1–20 hp • bypass contactors available as either integrated in the drive or
200 Vac, 3 Phase, 60Hz 1–20 hp barriered from the drive unit (<250 hp)
• line or load contactor (<125 hp VT/100 hp CT)
• line reactors (3 or 5%)
NOTE: Determine the type of application the drive will be applied to:
NOTE: 3% line reactors are standard above 50 hp VT or 40 hp CT
variable torque or constant torque. Variable torque ratings are to be @ 480V and above 25 hp VT or 20 hp CT @ 240V and above 20 hp
used on centrifugal pumps and fan loads which are considered light duty CT/VT @ 208V
with maximum 110% current overload. The Altivar 61 AC Drive is used • motor protecting filters or output reactors
for variable torque applications and has many specific features • pilot devices 22mm or 30mm
dedicated for pump and fan applications. Constant torque ratings are to
• unit extensions to provide additional panel space
be used on all other types of loads to provide normal duty and maximum
• wired and unwired control relays
overload capacity of 170%. The Altivar 71 AC Drive is used for constant
torque application and has increased rating and performance for
demanding loads.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 35
AC Drives

Altivar® AC Drive Features Options


• commissioning software for personal computers
Performance
• torque: sensorless flux vector control (ATV71 can include sensor for • I/O extension cards
tighter control) • 120 Vac interface card
• frequency range: 0.1 to 500Hz • Controller Inside option card
• speed range: 1 to 100 open loop • Modbus Plus™ communication card
• overtorque = 170% of nominal torque for 60 seconds (220% for 2 • Uni-Telway™/Modbus® communication card
seconds) for ATV71 Constant Torque rated drives and 110% of • Ethernet communication card
nominal torque for 60 seconds for ATV61 Variable Torque rated • DeviceNet™ communication card
drives • PROFIBUS communication card
• auto-tuning
• dynamic speed regulation
“Basic” Drive Power Circuit
Protective Features • Consist of disconnect switch and drive pre-programmed
• motor and inverter thermal protection for selected options if applicable.
• Unit is UL 845 Listed for 100,000 A Short Circuit
• short-circuit between phases and between phase and ground Current.
• main supply and motor phase loss • Includes operator LCD keypad/display mounted on
front of the unit.
• mains undervoltage and overvoltage • Pilot Devices are optional and are available as 22mm
XB4 or XB5 type pilot devices or 30mm 9001 Type K
• degraded operation on voltage dip pilot devices.
• Auto restart • Control power transformer (480 V/120 V), if necessary,
for enclosure ventilation fans is included.
• Catch on the fly with speed search

Monitoring and Indication


Door-mounted, LCD Type operator keypad: Displays setup parameters
and the last fault occurrence with plain text display. Factory preset for
the most common adjustments and the control schemes ordered with
the unit. Security to prevent accidental adjustments is provided by a
password. Programs are saved in the keypad allowing storage and
retrieval of four different programs between multiple drive units.
Real time display of:
• drive state (running, ready, accelerating, decelerating, etc.)
• reference frequency (in Hz)
• output frequency (in Hz)
• motor speed (in RPM)
• motor current (in Amps)
• mains voltage (in Volts)
• motor voltage (in volts)
• output power (in watts)
• motor thermal state (in %)
• drive thermal state (in %)
• energy consumed (Wh)
• last fault
• run time (hrs)
One normally open contact indication of drive running (closes on run).
One normally closed contact indication of drive fault (opens on fault).
Standard Analog output for motor current, motor frequency, ramp
output, motor power, and motor torque.

PE4 Discount Prices subject to change without notice.


36 Schedule 12/08
AC Drives
Combination Altivar 61 AC Drives (Variable Torque Rated)

Variable Torque Rated 480 Vac Drives With Circuit Breaker Disconnects
NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated
Max. Cont. Price Price
Horsepower @ Space Space Shipping
Output Amps Class 1, Ship Code Class 1,
460V (Inches) (Inches) Code
Type A Wiring Type A Wiring
1 2.1 $ 9400. $10000.
2 3.4 9600. 12 10200. 24
3 4.8 9800. 11100.
5 7.6 11200. 12600.
15 30
7.5 11 13000. 14400.
10 14 15000. 16400.
24
15 21 16000. 18000.
36
20 27 18400. C 20400. C
27
25 34 21400. 23400.
30 40 28400. 31400.
40 52 32000. 45 35000. 45
50 65 39000. 42000.
60 77 44000. 48000.
75 96 50000. 72 (20 W) 54000. 72 (20 W)
100 124 60000. 64000.
125 156 94000. 72 (25 W x 20 D)
150 180 104000.
200 240 114000. 72 (30 W x 20 D)
250 302 128000.
D Not available in NEMA Type 12
300 361 162000.
350 414 176000.
400 477 192000. 72 (35 W x 20 D)
450 515 212000.
500 590 230000.

Variable Torque Rated 480 Vac Drives With Fusible Switch Disconnects
Motor Rated NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Horsepower @ Max.
Cont. Out-
put Amps Price Class 1, Space Ship Price Class 1, Space
460 V Shipping Code
Type A Wiring (Inches) Code Type A Wiring (Inches)
1 2.1 $ 9000. $ 9600.
2 3.4 9200. 12 9800. 24
3 4.8 9400. 10600.
5 7.6 10800. 12200.
15 30
7.5 11 12600. 14000.
10 14 14600. 17000.
24
15 21 16200. 17600.
36
20 27 18000. C 20000. C
27
25 34 21000. 23000.
30 40 27400. 30400.
40 52 31000. 45 34000. 48
50 65 38000. 41000.
60 77 43000. 47000.
75 96 49000. 72 (20 W) 53000. 72 (2 0W)
100 124 58000. 62000.

Variable Torque Rated 240V AC Drives With Circuit Breaker Disconnects


NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated Max. Cont. Out- Price Price
Horsepower put Amps Space Ship Space Shipping
Class 1, Class 1,
(Inches) Code (Inches) Code
Type A Wiring Type A Wiring
1 4.2 $ 9800. $10400.
2 6.8 11200. 12 11800. 24
3 11 13000. 13800.
5 15.2 15000. 15 16400. 30
7.5 22 16600. 18000.
24 36
10 28 18400. 19800.
C C
15 42 28400. 30400.
20 54 32000. 45 35000. 45
25 68 39000. 42000.
30 80 50000. 54000.
40 104 60000. 72 (20 W) 64000. 72 (20 W)
50 130 94000. 98000.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 37
AC Drives
Combination Altivar 61 AC Drives (Variable Torque Rated)

Variable Torque Rated 240V AC Drives With Fusible Switch Disconnects


NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated
Max. Cont. Price Price
Horsepower @ Space Ship Space Shipping
Output Amps Class 1, Class 1,
230 V (Inches) Code (Inches) Code
Type A Wiring Type A WIring
1 4.2 $ 9400. $10000.
2 6.8 10800. 12 10400. 24
3 11 12600. 13400.
5 15.2 14400. 15 15800. 30
7.5 22 16200. 17600.
24 36
10 28 18000. 19400.
C C
15 42 28000. 30000.
20 54 31000. 45 34000. 48
25 68 38000. 41000.
30 80 49000. 53000.
40 104 58000. 72 (20 W) 62000. 72 (20 W)
50 130 92000. 96000.

Variable Torque Rated 208 Vac Drives With Circuit Breaker Disconnects
NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated
Max. Cont. Price Price
Horsepower @ Space Ship Space Shipping
200V Output Amps Class 1, Class 1,
Type A Wiring (Inches) Code Type A Wiring (Inches) Code

1 4.6 $ 9400. 12 $10400. 24


2 7.5 11200. 11800.
3 11 13000. 15 13800. 30
5 16.7 15000. 16400.
7.5 24 16600. 18000.
10 31 18400. 24 36
C 19800. C
15 46 28400. 45 30400. 45
20 59 32000. 35000.
25 75 39000. 42000.
30 88 50000. 72 (20 W) 54000. 72 (20 W)
40 114 60000. 64000.

Variable Torque Rated 208V AC Drives With Fusible Switch Disconnects


NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated
Horsepower @ Max.
Cont. Out- Price Price
put Amps Space Ship Space Shipping
200V Class 1, Class 1,
(Inches) Code (Inches) Code
Type A Wiring Type A Wiring
1 4.6 $ 9400. 12 $10000. 24
2 7.5 10800. 11400.
3 11 12600. 15 13400. 30
5 16.7 14400. 15800.
7.5 24 16200. 17600.
24 36
10 31 18000. C 19400. C
15 46 28000. 45 30000. 48
20 59 31000. 34000.
25 75 38000. 41000.
30 88 49000. 72 (20 W) 53000. 72 (20 W)
40 114 58000. 62000.

PE4 Discount Prices subject to change without notice.


38 Schedule 12/08
AC Drives
Combination Altivar 71 AC Drives (Constant Torque Rated)

Constant Torque Rated 480V AC Drives With Circuit Breaker Disconnects


NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated
Max. Cont. Price Price
Horsepower Space Ship Space Shipping
Output Amps Class 1, Class 1,
@460 V (Inches) Code (Inches) Code
Type A Wiring Type A Wiring
1 2.1 $ 9600. $10200.
2 3.4 9800. 12 11000. 24
3 4.8 11200. 12600.
5 7.6 13000. 14400.
15 30
7.5 11 15000. 16400.
10 14 16600. 18000.
24
15 21 18400. 20400. 36
C C
20 27 21400. 27 23400.
25 34 28400. 31400.
30 40 32000. 45 35000. 45
40 52 39000. 42000.
50 65 44000. 47000.
60 77 50000. 72 (20 W) 54000. 72 (20 W)
75 96 60000. 64000.
100 124 94000. 72 (25 W x 20 D)
125 156 104000.
150 180 114000. 72 (30 W x 20 D)
200 240 128000.
D Not available in NEMA Type 12
250 302 162000.
300 361 176000.
350 414 192000. 72 (35 W x 20 D)
400 477 212000.
450 515 230000.

Constant Torque Rated 480V AC Drives With Fusible Switch Disconnects


NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Motor Rated
Max. Cont. Price Price
Horsepower Space Ship Space Shipping
@ 460 V Output Amps Class 1, Class 1,
(Inches) Code (Inches) Code
Type A Wiring Type A Wiring
1 2.1 $ 9000. $ 9600.
2 3.4 9200. 12 9800. 24
3 4.8 9400. 10600.
5 7.6 10800. 12200.
7.5 11 12600. 15 14000. 30

10 14 14600. 16000.
15 21 16200. 24 17600. 36
C C
20 27 18000. 27 20000.
25 34 27400. 30400.
30 40 31000. 45 34000. 48
40 52 38000. 41000.
50 65 43000. 47000.
60 77 49000. 72 (20 W) 53000. 72 (20 W)
75 96 58000. 62000.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 39
AC Drives
Combination Altivar 71 AC Drives (Constant Torque Rated)

Constant Torque Rated 208/240V AC Drives With Circuit Breaker Disconnects


Motor Rated Horsepower NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Max. Cont. Price Price
@ 200 V @230 V Output Amps Class 1, Space Ship Class 1, Space Shipping
Type A Wiring (Inches) Code Type A Wiring (Inches) Code

— 1 4.6/4.2 $11200. $11800.


12 24
— 2 7.5/6.8 13000. 13800.
3 3 11/9.6 15000. 15 16400. 30
5 5 16.7/15.2 16600. 18000.
7.5 7.5 24/22 18400. 19800.
24 36
10 10 31/28 28400. C 30400. C
15 15 46/42 32000. 35000.
20 20 59/54 39000. 45 42000. 45

25 25 75/68 50000. 54000.


30 30 88/80 60000. 72 (20 W) 64000. 72 (20 W)
40 40 114/104 94000. 98000.

Constant Torque Rated 208/240V AC Drives With Fusible Switch Disconnects


Motor Rated Horsepower NEMA Type 1 and 1A (Gasketed) NEMA Type 12
Max. Cont. Price Price
Output Amps Ship Shipping
@ 200 V @ 230 V Class 1, Space Class 1, Space
Code Code
Type A Wiring Type A Wiring
— 1 4.6/4.2 $10800. $11400.
12 24
— 2 7.5/6.8 12600. 13400.
3 3 11/9.6 14400. 15800.
15 30
5 5 16.7/15.2 16200. 17600.
7.5 7.5 24/22 18000. 19400.
24 36
10 10 31/28 28000. C 30000. C
15 15 46/42 31000. 34000.
45 48
20 20 59/54 38000. 41000.
25 25 75/68 49000. 53000.
30 30 88/80 58000. 72 (20 W) 62000. 72 (20 W)
40 40 114/104 92000. 96000.

PE4 Discount Prices subject to change without notice.


40 Schedule 12/08
Solid-State Starters
Combination Altistart 48 Soft Starts
General Information
Altistart® 48 Motor Control Center Soft Start units are available from Contact the MCC TAG for additional application information and pricing
11–604 A in NEMA 1, 1A (Gasketed), 12, and 3R MCC enclosures. for those applications requiring:
Units are available for three (3) phase, 60 Hz, 208 V, 240 V, 480 V, or • 2 speed or delta-wye motors
600 V, 3 wire or 4 wire power systems. The Altistart 48 Soft Start in The ATS48 can operate with a 2-speed motor. A motor
MCCs can provide soft starting (reduced voltage) and deceleration demagnetizing period must elapse before changing from low speed
along with machine and motor protection of standard NEMA B-Design to high speed in order to avoid antiphase between the line supply and
three-phase squirrel cage asynchronous motors in the following power the motor, which would generate very high currents.
ranges:
• motors other than NEMA Design B
• 3–200 hp, 208 V • high efficiency motors
• 5–250 hp, 230 V • low slip motors
• 10–500 hp, 460 V • power factor correction capacitors
• 15–600 hp, 575 V Do not connect power factor correction capacitors to the terminals of
The MCC Soft Start units integrate the latest technology Altistart 48 Soft a motor controlled by an ATS48 soft start. The power factor
Start from Schneider Electric into a combination starter package for capacitors must be controlled and connected to a line side contactor
MCCs. MCC Soft Start units include a shorting contactor, shunt trip input sequenced by the ATS48 at end of starting.
power disconnect, door-mounted keypad and 120VAC control circuitry. • controller oversizing of more than 50%
Telemecanique D and F line contactors are standard (NEMA type • multi-motor applications
contactors are optional). All packages and options are UL 845 listed for Motors may be connected in parallel provided that the power limit of
a minimum 65,000 Amp short circuit rating up to 600V (ratings of the starter is not exceeded (the sum of the motor currents must not
100,000 Amps @ 600V are available with fuses). exceed the nominal current of the starter selected depending on the
All soft starter units with circuit breaker disconnects through 250 A and type of application). Individual thermal protection and local disconnect
800–1200 A frames use PowerPact® thermal magnetic (TM) circuit is required for each motor.
breakers. All soft starter units with 400–600 A frame disconnects use • non-standard trip characteristics
L-frame thermal-magnetic (TM) circuit breakers. The fusible switch • modifications not listed in this pricing guide
disconnects used on MCC Soft Start units are automatic molded case • horsepower greater than those listed in this pricing guide
switches. Provisions for Class J or L fuses are provided. Fuses are not • long motor cable lengths
installed at the factory. All units are UL listed. Very long motor cables cause voltage drops due to the resistance of
the cable. If the voltage drop is significant, it could affect the current
Selection consumption and the torque available. This criteria must be taken into
account when selecting the motor and the starter.
The ATS48 controller must be selected on the basis of 3 main criteria:
• Miscellaneous application precautions
• Main voltage supply: NOTE: Do not use the ATS48 controller upstream of loads other than
— Three-phase AC voltage: 208, 240, 480 ,or 600 V motors (for example transformers and resistance type loads)
• The power and the nominal current (motor FLA) indicated on the
motor nameplate
• The type of application and the operating cycle:
To simplify selection, the applications are categorized as two types:
— Standard duty applications
— Severe duty applications
Standard or severe duty applications define the limiting values of the
current and the duty cycle ratings.

Standard duty application


In standard duty applications, the ATS48 controller is designed to
provide:
• Starting at 400% nominal motor current (In) for 23 seconds or at
300% nominal motor current (In) for 46 seconds from a cold state
• Starting at 300% nominal motor current (In) for 23 seconds or at
400% nominal motor current (In) for 12 seconds with a load factor of
50% and 10 starts per hour or an equivalent thermal cycling
The motor thermal protection conforms to Class 10 overload protection

Severe duty application


In severe duty applications, the ATS48 controller is designed to provide:
• Starting at 400% nominal motor current (In) for 48 seconds or at
300% nominal motor current (In) for 90 seconds from a cold state
• Starting at 400% nominal motor current (In) for 25 seconds with a
load factor of 50% and 5 starts per hour or an equivalent thermal
cycling
The motor thermal protection conforms to Class 20 overload protection.
See the Altistart 48 catalog (8636CT0201) and technical publication
8600PD9201 for additional information.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 41
Solid-State Starters
Combination Altistart 48 Soft Starts
Features Monitoring and Indication
Shorting Contactor: A shorting contactor is supplied on all units. This Door mounted keypad:
allows the motor current to bypass the Soft Start's thyristors once the • Displays setup parameters and fault codes.
Soft Start has ramped up to full voltage/full speed. The use of a shorting
• Factory preset for most common adjustments.
contactor reduces temperature rise within the enclosure during steady
• Security to avoid accidental controller modifications is provided by dip
state operation and requires less current carrying duty on the thyristors.
switches on the back of the keypad which must be adjusted to provide
(TCS™) Torque Control System access to 3 programming levels.
The Altistart 48 uses TCS ramping to accelerate the motor to full voltage. Real time indication via the digital keypad of:
Basing the acceleration ramp on the motor torque rather than current or • Motor current
voltage, as used in traditional soft starts, provides a linear speed ramp
• Load Torque
independent of the motor loading without tachometer feedback. The
• Motor thermal state
TCS ramp is also used for improved control of deceleration and
• Power factor
eliminates the need for a special controller to handle water hammer
problems. • Fault status
Two logic outputs:
Starting and Stopping
• Motor thermal overload or indication of motor current present
Four types of starting are available:
• Current threshold alarm
• TCS soft start—adjustable from 1 to 60 seconds • Motor underload alarm
• TCS with “boost”—adjustable 50 to 100% of mains voltage
One analog output for 4 to 20 or 0 to 20 mA indication of motor current,
• Current limit—adjustable from 150 to 500% of controller rating torque, thermal state, active power or power factor.
• voltage ramping
Two logic inputs, which are configurable for force to freewheel, thermal
Three types of stopping are available
overload reset or indication of external fault.
• Freewheel or coast to stop Options:
• TCS soft stop—adjustable from 1 to 60 seconds • Input Isolation Contactor
• InTele™ Braking—adjustable from 50 to 100% • Full Voltage Bypass
Protective Features • NEMA hp-rated contactors substituted for Telemecanique D or F line
• Solid State motor thermal overload protection—programmable from contactors
Class 10 through 30 • Reversing
• Soft Start thermal protection • 120 Vac Control Power Transformer
• Motor Phase loss protection • 120 Vac customer VA capacity added to control power transformer
• Line supply failure • Push To Test Pilot Lights
• Overcurrent fault • LED Pilot Lights
• Locked rotor fault • Auxiliary interlocks
• Line frequency outside limits +/-5% or +/-20% • Network Communications: Modbus®, DeviceNet™, PROFIBUS, and
• Selectable protection, including: Ethernet
— Phase reversal
— Stall and jam
— Thermal overload pre-alarm
— Current threshold alarm
— Underload fault
• Transient Suppression Modules on all contactors

PE4 Discount Prices subject to change without notice.


42 Schedule 12/08
Solid-State Starters
Combination Altistart 48 Soft Starts

Standard Duty Altistart 48 Soft Starts With Circuit Breaker Disconnects


(Pumps, Fans, Lightly Loaded, or Unloaded Starting Applications)
Motor Rated Horsepower shown for convenience only. Size per actual motor full load amperes. For Severe Duty Applications, choose the next larger horsepower size.
Price Space a
Starter Type and Horsepower TM Trip/
Soft Start Max. U nit Type B-D (Inches) Ship
Frame Amps Frame Code
(Amps) IEC NEMA IEC NEMA
200 V 230 V 460 V
Contactors Contactors Contactors Contactors
3 — — 10 20/150
— — 10 D17 14 25/150 $10400. $10800.
— 5 — 15 30/150
5 — — 16 30/150
— — 15 D22 21 40/150 11200. 12000.
— 7.5 — 24 45/150
7.5 — — 24 45/150 30 42
— — 20 D32 27 50/150 11800. 12600.
— 10 — 28 50/150
10 — — 30
D38 60/150 12400. 13200.
— — 25 34
— — 30 D47 40 80/150 14600. 15800.
— 15 — 42
15 — — 46
— — 40 D62 52 110/150 16000. 17200.
— 20 — 54 C
20 — — 59
— — 50 D75 65 110/150 18400. 20000.
— 25 — 68
30 42
25 — — 74
— — 60 D88 77 110/150 21600. 23000.
— 30 — 80
30 — — 88 125/150
— — 75 C11 96 125/150 23000. 24400.
— 40 — 104 150/150
40 — — 114 175/250
— — 100 C14 124 200/250 25800. 27200.
— 50 — 130 200/250
42 60
50 — — 143 200/250
— 60 — C17 154 225/250 30800. 34800.
— — 125 156 225/250
60 — — 169
— — 150 C21 180 250/600 34200. 38200.
— 75 — 192
75 — — 211
72 72
— — 200 C25 240 450/600 37000. 41000. (20 W X 20 D) (30 W X 20 D)
— 100 — 248
100 — — 273
— — 250 C32 302 450/600 44800. 53800.
— 125 — 312
125 — — 343 D
— 150 — C41 360 600/800 52600. 61600.
— — 300 361
72 72
150 — — C48 396 600/800 56800. 65800.
— — 350 414 (35 W X 20 D) (35 W X 20 D)

— — 400 477
C59 800/800 69400. 78400.
— 200 — 480
200 — — 528 800/800 Not 72 Not
— — 500 C66 590 1000/1200 71400.
Available (35 W X 20 D) Available
— 250 — 604 1000/1200
a Space shown is applicable to NEMA 1, 1A, 12, and 3R enclosures. Options may require additional space.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 43
Solid-State Starters
Combination Altistart 48 Soft Starts

Standard Duty Altistart 48 Soft Starts With Fusible Switch Disconnects


(Pumps, Fans, Lightly Loaded, or Unloaded Starting Applications)
Motor Rated Horsepower shown for convenience only. Size per actual motor full load amperes. For Severe Duty Applications, choose the next larger horsepower size.
Power Fuses are not included.
Price Space a
Starter Type and Horsepower Soft Max. F/S Type B-D (Inches) Ship
Start Unit Amps Code
Frame Amps (Fuse Class) IEC NEMA IEC NEMA
200 V 230 V 460 V 575 V
Contactors Contactors Contactors Contactors
3 — — — 10
— — 10 — 14
D17 30 (J) $10000. $10400.
— 5 — — 15
— — — 15 17
5 — — — 16 30 (J)
— — 15 — 21 30 (J)
D22 10800. 11600.
— — — 20 22 60 (J)
— 7.5 — — 24 60 (J)
7.5 — — — 24 30 42
— — 20 25 D32 27 60 (J) 11200. 12000.
— 10 — — 28
10 — — — 30
— — — 30 D38 32 60 (J) 11800. 12600.
— — 25 — 34
— — 30 — 40
— — — 40 D47 41 100 (J) 14000. 15200. C
— 15 — — 42
15 — — — 46
— — 40 50 D62 52 100 (J) 15400. 16600.
— 20 — — 54
20 — — — 59
— — — 60 62
D75 200 (J) 18200. 19400.
— — 50 — 65
— 25 — — 68
30 42
25 — — — 74
— — 60 75 D88 77 200 (J) 20000. 21400.
— 30 — — 80
30 — — — 88
— — 75 — 96
C11 200 (J) 22200. 23600.
— — — 100 99
— 40 — — 104
40 — — — 114 200 (J)
— — 100 — C14 124 400 (J) 24600. 26000.
— — — 125 125 400 (J)
— 50 — — 130 400 (J)
42 60
50 — — — 143
— — — 150 144
C17 400 (J) 19400. 33400.
— 60 — — 154
— — 125 — 156
60 — — — 169
— — 150 — C21 180 400 (J) 32800. 36800.
— 75 — 200 192
75 — — — 211 400 (J)
— — 200 — 240 600 (J)
C25 35600. 39600. 72 72
— — — 250 242 600 (J)
(30 W X 20 D) (30 W X 20 D)
— 100 — — 248 600 (J)
100 — — — 273
— — — 300 289 D
C32 600 (J) 43000. 52000.
— — 250 — 302
— 125 — — 312
— — — 350 343 600 (J)
125 — — — 343 600 (J)
C41 49600. 58600.
— 150 — — 360 800 (L)
— — 300 — 361 800 (L)
— — — 400 382 72 72
150 — — — C48 396 800 (L) 53800. 62800. (30 W X 20D ) (30 W X 20 D)
— — 350 — 414
— — — 500 472
— — 400 — C59 477 1000 (L) 66400. 75400.
— 200 — — 480
200 — — — 528 1000 (L)
— — — 600 580 1000 (L) Not 72 Not
C66 68400.
— — 500 — 590 1200 (L) Available (35 W X 20 D) Available
— 250 — — 604 1200 (L)
aSpace shown is applicable to NEMA 1, 1A, 12, and 3R enclosures. Options may require additional space.

PE4 Discount Prices subject to change without notice.


44 Schedule 12/08
AC Drives and Solid-State Starters
NEMA Type 3R Enclosure Applications for Altivar 61/71 AC Drives and Altistart 48 Soft Starts
NEMA 3R MCCs manufactured by Schneider Electric are non-walk-in enclosures with a design based on the standard NEMA 1 MCC. Additional
housing and gasketing provide protection from rain, sleet, and ice.The NEMA 3R MCC for ac drives and soft starts features louvered and filtered
openings on the front doors, along with humidity controls inside the enclosure (see the figure below). The MCC enclosure is further modified to include
fan-forced ventilation while continuing to meet NEMA 3R enclosure requirements and the UL 845 MCC standard.

Ventilated NEMA 3R
D D D

Environmental
Controls

Filtered
Ventilation
Transformer
Power Supply
for Fans
Environmental
Controls
Space
Heaters

Front View of NEMA Type 3R MCC Side View of NEMA Type 3R MCC
(dashed lines represent units)

Environmental Control
The ventilated NEMA 3R MCC manages the internal MCC environment Ratings
to maintain the required temperature and humidity levels for the drive • Altivar® 71: 1-40 hp, 480V, or 1-15 hp, 208/230Va
and soft start controls in outside environments from -10 to 40 °C (14 to • Altistart® 48 Soft Start: 10-500HP, 480V
104 °F). The following features are included: 15-600HP, 600V
• Dual Door Fans – Dual door fans force fresh air into the enclosure and 5-250HP, 240V
move air out of the enclosure. The centrifugal impeller fans use highly 3-200HP, 208V
reliable ball bearing rotors. A factory-preset thermostat controls the a A maximum of four ATV71 drives are allowed in a single section. Mount drive
fans, based on the MCCs internal temperature. Door interlock units starting at the top of the section.
switches turn the fans off when the outer NEMA 3R door is opened.
• Positive Pressure Ventilation – The intake fans, mounted at the lower NOTE: In hotter climates, Schneider Electric suggests installing a shed
vents, blow air into the cabinet. This air increases the cabinet's for shading the MCC as a best practice, since high temperatures are not
internal air pressure relative to the air pressure outside the cabinet. always consistent.
The “positive” air pressure created inside the cabinet helps force out • Altivar 71: Use constant torque ratings for variable torque applications.
dirt and contaminants. This positive pressure ventilation method is • -10 to 40 °C (14 to 104 °F)
common practice for industrial atmospheres: it provides a cleaner • up to 2000 A horizontal bus
environment for drive and soft start electronics than one that would be • Outdoor, Rainproof, Sleet Resistant Enclosure (NEMA 3R)
created by exhaust fans mounted at the upper vents.
• UL 845 Listed
• Space Heaters – Space heaters add heat to prevent condensation • 0–480 Vac, 3Ø3W or 3Ø4W
during cooler periods, overnight and in winter weather.
• Non-Walk-In
NOTE: Space heaters do not allow application of the MCC in
temperatures below -10 °C (14 °F). Product Selection
• Humidity Controls – It is crucial to maintain a level of dryness in or The product is only available for pricing in Quote To Cash Product
around the electronic controls for drives and soft starts. Condensation Selectors. There are special instructions to follow for proper entry of
must be avoided. The space heaters will supply the MCC with heat NEMA 3R Drives and Soft Starts. If these instructions are not followed,
when necessary to reduce condensate formation. A factory-preset you will receive a validation warning. The instructions are located below
thermostat and humidistat monitor humidity levels and turn on the and in the Quote To Cash Help Screens.
space heaters to dry the internal MCC ambient air. 1. Enter into Quote To Cash using the MCC Product Selector.
• Self-Contained Power Supply – The fused control transformer(s)
2. Select Type 3R as the Enclosure Type.
supplied in each MCC line-up provide power for space heaters and
fans. There is no need for external power once the main 3-phase 3. Enter Drives and Soft Starts as normal, while following the maximum
power is connected. The power supply is pre-wired at the factory to NEMA 3R horsepower ratings in the Ratings section above.
fans, space heaters, and environmental controls through protected 4. One 15 in. power supply unit must be included in the quote per every
wiring provisions. Each transformer is able to supply power to three three MCC sections for the MCC environmental controls. To do this
sections and should be mounted at the bottom of the MCC section. go to the Distribution Transformer MCC device and select a single
• Filtered Louvers – Each NEMA 3R MCC door contains top and bottom phase, 120 secondary, 1.5kVA unit. It is important to include one
louvers for ventilation. Behind each louver is a coarse rubber filter power supply unit in every three sections to get a correct MCC
that helps protect against debris entering the MCC. layout. Each power supply is able to supply power to three sections
NOTE: All drives and soft starts include internal thermal protection and should be mounted at the bottom of the MCC section. The
switches to shut down the drive or soft start unit before damage occurs. Seneca plant may have to return corrected approval drawings if the
layout is incorrect; resulting in possible shipping delays.
NOTE: After any errors/warnings are cleared, use the User Placement
tool to place the largest drives/soft starts in the top position of the MCC
sections and to place the power supply transformers as noted in step
seven above. Also note a maximum of four Altivar 71 Drives are allowed
in a single section. Locate drive units starting at the top of the section.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 45
Unit Options

Options And Modifications


Various options can be provided on Model 6 units to meet specific allow additional unit space for customer requirements (see page 57).
customer requirements. Many options require additional mounting Some units (primarily full section 72 in. units) contain room for limited
space as indicated in the following tables. It is not necessary to add a options without the need for the additional space listed. Contact the
unit extender modification to accommodate the additional space listed MCC TAG for additional information or layout assistance.
below. The space requirements listed are for typical unit arrangements. NOTE: Unit options listed are based on factory-selected components.
Unusual combinations or variations may require additional space. Other devices are available with minimal shipping code G. Contact the
The total space added to any one unit should total 3, 6, 9, 12, or 24 in. MCC TAG for pricing and shipping code.
to avoid multiple unit extenders. Unit extenders may be specified to

Control And Timing Relays


Space Shipping
Description Application Price
(Inches) Code
5-pole Control Relay D-line (unwired), (3 NO + 2 NC) Starter or MT unit $ 302.
5-pole Control Relay D-line (wired), (3 NO + 2 NC) Starter or MT unit 542.
4-pole Control Relay Type X (unwired), (2 NO + 2 NC) Starter or MT unit 704.
4-pole Control Relay Type X (wired), (2 NO + 2 NC) Starter or MT unit 944.
9-pole Control Relay D-line (unwired), (5 NO + 4 NC) Starter or MT unit 356.
9-pole Control Relay D-line (wired), (5 NO + 4 NC) Starter or MT unit 788.
8-pole Control Relay Type X (unwired), (4 NO + 4 NC) Starter or MT unit 1056.
8-pole Control Relay Type X (wired), (4 NO + 4 NC) Starter or MT unit 1488.
5-pole Latching Relay D-line (unwired), (3 NO + 2 NC) 4-pole relay with mechanical latch 514. 3 D
5-pole Latching Relay D-line (wired), (3 NO + 2 NC) 4-pole relay with mechanical latch 754.
4-pole Latching Relay Type X (unwired), (2 NO + 2 NC) 4-pole relay with mechanical latch 1174.
4-pole Latching Relay Type X (wired), (2 NO + 2 NC) 4-pole relay with mechanical latch 1414.
Pneumatic Timer D-line (unwired), (3 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed Contacts On Delay 524.
Pneumatic Timer D-line (wired), (3 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed Contacts On Delay 860.
Pneumatic Timer D-line (unwired), (3 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed Contacts Off Delay 524.
Pneumatic Timer D-line (wired), (3 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed Contacts Off Delay 860.
Pneumatic Timer Type X (unwired), (2 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed
On Delay 1544.
Contacts
Pneumatic Timer Type X (wired), (2 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed Contacts On Delay 1880.
Pneumatic Timer Type X (unwired), (2 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed
Off Delay 1544. 3 D
Contacts
Pneumatic Timer Type X (wired), (2 NO + 2 NC) Instantaneous and (1 NO + 1 NC) Timed Contacts Off Delay 1880.
(1) Timed Circuit 1056.
Motor Operated Timing Relay, (Single Timing Step) (2) Timed Circuit 1360. 6 G
Each Instantaneous Contact 126.
Multifunction Timing Relay Type RE7 (unwired) ck 2PDT (form C) Multifunction 754.
3 D
Multifunction Timing Relay Type RE7 (wired) ck 2PDT (form C) Multifunction 898.
2-pole Control Relay SK-line (unwired), (1 NO + 1 NC) Starter or MT unit 122.
2-pole Control Relay SK-line (wired) , (1 NO + 1 NC) Starter or MT unit 266.
3-Pole Control Relay Type K (unwired) c, 3PDT (form C) General Purpose 146.
3-Pole Control Relay Type K (wired) c, 3PDT (form C) General Purpose 338.
0 D
4-Pole Control Relay Type R (unwired) c 4PDT (form C) General Purpose 136.
4-Pole Control Relay Type R (wired) c, 4PDT (form C) General Purpose 376.
Phase Failure Relay Type MP (unwired) c, SPDT (form C) Phase Failure 860.
Phase Failure Relay Type MP (wired) c, SPDT (form C) Phase Failure 1050.
c Fusible FVNR units Size 1 and 2 require 3 in. of space, max. (1), not available in Compac™ starters with CPT.
k Instantaneous contacts not available.

Special Function Relays


Description Application Price Space (Inches) Shipping Code
Duplex Alternator Used with two Combination Starters $ 658.
Compelling Relay 2-Speed Starters 790.
0a
Accelerating Relay 2-Speed Starters 1002. F
Decelerating Relay 2-Speed Starters 1002.
Over/Undervoltage Relay Starter Units (Single Phase – 120 V) 1782. 3
a Compelling, Accelerating, and Decelerating Relays when used with Size 3 and 4 ,2-speed, 2-winding starters require 6 in. of mounting space.

Motor Winding Heaters


Description Application Price Space (Inches) Shipping Code
3–100 hp @ 480 V $3170.
Motor Winding Heater 0 G
101–300 hp @ 480 V 3876.

PE4 Discount Prices subject to change without notice.


46 Schedule 12/08
Unit Options

Unit Nameplates
List nameplate data in the Quote-To-Cash nameplate information screen. White letters on gray background standard.
Price
Description Application Space (Inches) Shipping Code
Standard Industrial
White Letters on Gray
B
Unit Nameplate Engraved Black Letters on White
$ 20. N/C 0
(1.5 in. x 6.5 in.) White Letters on Black
D
White Letters on Red
Unit Nameplate other than standard size 450. $450. 0 G
All
Stainless Steel Nameplate mounting hardware 20. 20. — F
White Letters on Gray
B
Master Nameplate Engraved Black Letters on White
194. 194. 0
(8 in. x 10 in.) White Letters on Black
D
White Letters on Red

Control Circuit Variations


Space Shipping
Description Application Description Price
(Inches) Code
Unfused Separate 120 V Standard on all starters unless SPDT N/C
Control Circuit with control power transformer is chosen. (All Size 6 starters
Control Power Disconnect have control power transformer as standard) DPDT $ 194. 0 B
Fused Separate 120 V SPDT 92.
Control Circuit with Includes one fuse and control circuit interlock.
Control Power Disconnect DPDT 290.
Control power taken between phases N/C 0 E
Fused Line Voltage Control
Circuit (two primary fuses) Control power taken from phase and neutral 180.
SPDT 126.
Operating Mechanism Interlock j
DPDT 194.
50VA (23) 360. 0
100VA (73) 408.
Size 1 FVNR
150VA (123) 528.
300VA (273) 650. 6
100VA (62) 408.
Size 1 FVR and 2-Speed;
150VA (112) 528.
All Size 2
300VA (262) f 650. 0
150VA (104) 582. B
All Size 3, except (208, 240, and
2-Speed 1-Winding 300VA (253) 650. 480 V primary
Fused Control Power Transformer
(two primary fuses and one secondary to 120 V
500VA (453) 1038. 9
fuse as standard) secondary)
300VA (211) 650.
VA rating shown in parentheses ( ) is the excess 0 G
All Size 4 and Size 3 (Others)
capacity for other control devices after subtracting the 2-Speed 1-Winding 500VA (411) 1038.
contactor requirements.
750VA (661) 1328. 9
50VA (25) 650.
100VA (75) 718.
All Size 5 and All RVAT
(Use Line Voltage Coil 150VA (125) 820.
with Interposing Relay)
300VA (275) k 940.
0
500VA (475) p 1328.
150VA (15) STD N/C
All Size 6 300VA (165) 874.
450VA (315) 1134.
Size 1-5 Starters
Transient Suppression Module 102. 0 C
(Maximum coil voltage = 120 V)
f 6 in. required on Size 1 2-Speed and all Size 2 starters.
k 6 in. required on Size 1-3 RVAT and RVPW.
p 9 in. required on Size 1-3 RVAT and RVPW.
j Not suitable for use as loss source indication. (See page 58).

Prices subject to change without notice. PE4 Discount


12/08 Schedule 47
Unit Options

Pilot Devices
Model 6 Motor Control Centers use Class 9001 Type XB5 22 mm pilot devices as standard. Starters are provided with a removable hinged station plate
that has five knockouts for XB5 (maximum of 3 Type K 30 mm devices). Compac™ 6 starters are provided with a control station plate that has knockouts
for four Class 9001 Type XB5 22 mm pilot devices. Type K devices can not be substituted on Compac 6 starters.
NOTE: When more pilot devices are specified than will fit in the station plate, the additional devices will be mounted directly in the unit door, with revised
shipping code of D. Not applicable to Compac 6.

Space Shipping
Description Application Price (Inches) Code
FVNR, RVAT $ 146. B
Start-Stop Push Button
Any Other Starter q E
Start-Stop Push Button with Manual Speed Potentiometer AC Drives 718. C
Forward-Reverse-Stop Push Button FVR
B
High-Low-Stop Push Button 2-Speed
280.
Fast-Off-Slow Push Button 2-Speed
High-Low Push Button 2-Speed
Fast-Slow Push Button 2-Speed
On-Off Push Button Any Starter c 146. D
Single Function Push Button Any Starter c 96.
Illuminated Push Button Any Starter c 97.
Maintain Contact Push Button Any Starter c 140.
FVNR, RVAT 146. B
H-O-A Selector Switch
Any Other Starter c 146. D
Hand-Off-Auto Selector Switch with Manual Speed Potentiometer AC Drives 718. C
Start-Stop Selector Switch FVNR, RVAT, FVPW
D
On-Auto Selector Switch Any Starter c
FVNR C
On-Off Selector Switch
Any other starter c
146. 0
High-Off-Low Selector Switch 2-Speed
Hand-Auto Selector Switch Any Starter c
Test-Auto Selector Switch Any Starter c
Forward-Off-Reverse Selector Switch FVR
Forward-Off-Reverse Selector Switch with Manual Speed Potentiometer AC Drives 718.
D
High-Low Selector Switch 2-Speed
Slow-Off-Fast Selector Switch 2-Speed
Slow-Fast Selector Switch 2-Speed 146.
Forward-Reverse Selector Switch FVR
High-Low-Off Selector Switch 2-Speed
4-Position Selector Switch Any Starter—Type K Operators c 194.
2-Circuits or Less 1094.
Switchboard Type Rotary Cam Selector Switch G
Each Additional Circuit 97.
Substitute Type K Pilot Devices (XB5 STD.) (N/A on Compac™ 6) Any Starter (Max. 3 Type K Devices) 24. —
Substitute Type XB4 Pilot Devices (XB5 STD.) Any Starter (per operator) —
38.
Addition of Dust Boots to above Pilot Devices Price Adder for Each Operator E
(per operator)
Omit Control Station Plate Units without Pilot Devices C
(Solid Steel Unit Door) N/C
Units with Pilot Devices (Door Mounted) F
q For shipping code E, provide customer drawing. If drawing is not provided, use shipping code F.
c Any starter application requires a diagram with order entry.

PE4 Discount Prices subject to change without notice.


48 Schedule 12/08
Unit Options

Pilot Lights
Model 6 Motor Control Centers use Class 9001 Type XB5 22 mm pilot devices as standard. Starters are provided with a removable hinged station plate
that has five knockouts for XB5 (maximum of 3 Type K 30 mm devices). Compac™ 6 starters are provided with a control station plate that has knockouts
for four class 9001 Type XB5 22 mm pilot devices. Type K and push-to-test devices can not be substituted on Compac™ 6 starters.
NOTE: When more pilot devices are specified than will fit in the station plate, the additional devices will be mounted directly in the unit door, with revised
shipping code of D. Not applicable to Compac 6.

Description Application Incandescent LED Shipping Code


FVNR, RVAT, FVPW, AC Drive c $ 164. $ 188.
B
“ON” (Red, Green) FVR, 2-Speed (2 lights) 330. 376.
Wye-Delta 164. 188. D
FVNR, FVR, 2-Speed, RVAT, FVPW B
“OFF” (Red, Green) 232. 256.
Wye-Delta D
Pilot Lights
Red
Green 188.
“ON” indicating. For light with “OFF”
Special Configuration f Yellow 164. D
indication, add $68. to list price.
Blue
NA
White
FVNR, RVAT, FVPW 232. 256.
B
“ON” (Red, Green) FVR, 2-Speed (2 lights) 464. 512.
Wye-Delta 232. 256. D
FVNR, FVR, 2-Speed, RVAT, FVPW B
“OFF” (Red, Green) 300. 324.
Wye-Delta D
Push-To-Test Pilot Lights
Red
Green 256.
“ON” indicating. For light with “OFF”
Special Configuration f Yellow indication, add $68. to list price. 232. D
Blue
NA
White
Red
“RUN”
Green
Red 256.
Push-To-Test Pilot Lights “STOPPED” AC Drives c — C
Green
“FAULT”
Yellow
“HAND” and “AUTO” 512.
Substitute Type K 24. 24.
Any Starter —
Substitute Type XB4 (per operator) (per operator)

c LED-type direct supply.


f Any starter application requires a diagram with order entry.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 49
Unit Options

Auxiliary Electrical Interlocks q Overload Relays

Shipping
(Inches)
Space

Code
Shipping
Contacts Price Description Application Price

Code
Max. Aux. Interlocks
Description
Per Contactor
Type Type
NO NC Melting Alloy Overload Relay All Starters N/C
A B-D
Ambient Compensated Size 1–4 All $ 92. 0q B
Type Size Qty. 0 1 $ 68. $126. Bi-Metallic Overload Relay Size 5–6 All 242.
1-2 4 0 2 140. 252. TeSys® T Motor Management Any Starter
FVNR Controller
3-6 4 0 3 216. 378. Motor Logic® Solid State Overload Size 1-4 FVNR and See following
1-2 4 Relay (SSOLR) FVR Starters pages.
FVR c 0 4 280. 504. Motor Logic Plus™/Motor Logic Plus
3-5 2 Any Starter
II SSOLR
1 0 68. 126. Isolated Alarm Contact – N.O. Melting Alloy Only 106. 0 D
CHP:
1-4 2 Overload Alarm Light (Amber) f Melting Alloy, Bimetal 270. k
Low 1 1 140. 252.
When the starter has Overload Alarm Light – LED 0 B
(Amber)f Melting Alloy, Bimetal 296. k
CHP: 1-2 4 more than one 1 2 214. 378.
contactor (FVR, B Converts Combination
1-Winding
2-Speed

High 3-4 2 RVAT, 2-Speed), 1 3 280. 504. Omit Overload Relay Starter to Combination N/C 0 C
indicate which Contactor.
CVT: 1-2 4 contactor receives the
Omit External Overload
interlock. 2 0 140. 252. ---- N/C 0 E
Low 3-4 2 Reset Button
Size 1 Starters 440. 6
CVT: 1-4 2 1 214. 378. Additional Overload Relay
2 Size 2 Starters 610. 6
High (See NEC 430-53 for proper G
2 2 280. 504. application) Size 3 Starters 688. 9
1-2 4 3 0 214. 378. Size 4 Starters 800. 12
2-Speed All standard melting
2-Winding 3 3 3 1 280. 504. alloy and bimetal 196.
Factory -Installed thermal units (set of 3)
4 2 4 0 280. 504. Thermal Units v r
Type FB Quick Trip 0 D
(Will be sized per NEC 430-150, 214.
RVAT 3-6 5 (set of 3)
unless FLC provided with order)
Type SB Slow Trip
q Elapsed Time Meters, Transient Suppression Module, and Off Pilot Light use (set of 3) 262.
one auxiliary interlock each. Size 1 starters with three auxiliary interlocks
require a minimum 100VA control power transformer. f Not available on Size 3 and 4 starters with bimetal overload.
c Maximum of 2 interlocks per contactor for Compac™ 6 starters. k Price includes overload alarm contact.
v Order must include thermal unit selection or motor full load current ratings.
r 2-Speed and part-winding starters require six (6) thermal units.
q Size 3 2-Speed 1-Winding requires a 9 in. space adder.

PE4 Discount Prices subject to change without notice.


50 Schedule 12/08
Unit Options

TeSys® T Motor Management Controller


The TeSys T controller connects directly to the communication The Tesys T Motor Management Controller includes:
network offering data monitoring and control. Communication users • Native open communication protocol
gain access to motor data variables and system process control through
• Six discrete inputs and three relay outputs
“onboard” I/O. The TeSys T controller includes thermal overload,
• RJ-45 port for connection to expansion module, HMI display, or PC
over/under current, long start/jam, ground fault, and phase failure/
• 24 Vdc or 120 Vac, 50/60 Hz control power
unbalance protection. In addition, when combined with a PLC, the
Tesys T controller provides an independent data monitoring and control • Status indicating LEDs
system. — HMI communication—Communication between controller and
HMI device
The TeSys T controller is available in five different native, open
— Power—controller state
communication protocols: CANopen, DeviceNet™, Ethernet, Modbus®,
and PROFIBUS. — Alarm—Warning or fault condition
— Fallback—Communication loss on active control source
Voltage and load monitoring is available by selecting the optional
— PLC communication—Network status
Expansion Module. The additional motor monitoring includes over/under
voltage, phase reversal, over/under power factor, and load shedding. In • Fault relay—1 N.O. and 1 N.C.
addition, the optional HMI may be supplied on each unit to provide local • Ground Fault CT input
monitoring, configuration, and control functions. • Thermistor/PTC input

TeSys T and Motor Logic Plus™ Family SSOLR Space TeSys T Application Notes:
Addition Requirements–Circuit Breaker Type Disconnects The TeSys T Motor Management Controller is not available with vacuum
Size FVNR FVR 2S2W 2S1W RVAT PW starters, Altivar® drives, or Compac® 6 starters.
1 0 in. 3 in. 3 in. 3 in. N/A 0 in.
2 0 in. 3 in. 3 in. 3 in. N/A 0 in. TeSys T Pricing
3 0 in. 0 in. 0 in. 0 in. 3 in. 0 in. Communication
Size 1-3 Price Size 4-6 Price Shipping Code
Protocol
4 3 in. 15 in. 27 in. 27 in. 6 in. N/A
FVNR, FVR, RVAT
5 0 in. 25 in. 0 in. 0 in. 0 in. N/A Modbus $2200. $3200.
C
6 0 in. N/A N/A N/A 0 in. N/A DeviceNet 2400. 3400.
PROFIBUS 2800. 3800.
D
TeSys T and Motor Logic Plus Family SSOLR Space Addition CANopen 2400. 3400.
Requirements–Fusible Switch Type Disconnects Ethernet 3400. 4400. C
Size FVNR FVR 2S2W 2S1W RVAT PW Two-speed, part-winding
Modbus 4400. 6400.
1 0 in. 3 in. 3 in. 3 in. N/A 0 in.
DeviceNet 4800. 6800.
2 0 in. 3 in. 3 in. 3 in. N/A 0 in.
PROFIBUS 5600. 7600. D
3(100 A) 3 in. 0 in. 0 in. 0 in. 3 in. 0 in.
CANopen 4800. 6800.
3(200 A) 0 in. N/A N/A N/A N/A N/A Ethernet 6800. 8800.
4 9 in. 15 in. 27 in. 0 in. 0 in. N/A
5 0 in. 0 in. 0 in. 0 in. 0 in. N/A TeSys T Options
6 0 in. N/A N/A N/A 0 in. N/A Shipping
Option Description Price
Code
Voltage and Load monitoring. Four
Expansion
additional logic inputs. Powered $1120.
Module
through the controller. RJ-45 port.
Programming port. Mounted in 22mm
RJ-45 Port control station plate. Door mounted if 232.
more than five 22mm pilot devices.
Door mounted operator interface. LCD
HMI display. RJ-45 port.
1120.
Hand held HMI, enables configuring
Programmer
and commissioning of the controller.
Measures ground faults at levels
Ground Fault significantly lower than the ground 1200. B
CT fault detection based on the internal
summation of the 3 phase currents.
Reset Push Mounted in 22mm control station
96.
Button plate. Local Operator reset.
Enables configuring and
PowerSuite™ commissioning of the controller.
1600.
Software Default logic can be modified or new
logic can be created with this software.
Warning Pilot CSP Mounted, provides visibility of
Light TeSys T Warning.
164.
Fault Pilot Light CSP Mounted, provides visibility of
TeSys T Fault.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 51
Unit Options

Motor Logic® Solid State Overload Relays (SSOLR) Motor Logic Plus™ SSOLR
The Motor Logic solid-state overload relay family of products offers a The Motor Logic Plus family of solid state overload relays are
degree of flexibility for selecting the amount of motor protection or programmable electronic overloads with motor protective features and
control you require. Coupled with the Square D® brand Type S contactor, communications capabilities.
the Motor Logic overload relays form the benchmark for NEMA style The Motor Logic Plus provides voltage and current monitoring with an
motor starters. Available fully integrated in the Model 6 Motor Control integral LED display. The communication port allows for connectivity to
Center, forming a complete power and control system. an upstream network.
Being able to select the degree of protection or control desired is only The Motor Logic Plus II provides protective and control functions. The
one of the many reasons the Motor Logic solid-state overload relay Motor Logic Plus II integrates I/O with four digital inputs and two relay
family of products is superior. Beginning with the Motor Logic base unit outputs for network control functions.
the choice is yours.
Motor Logic Plus Family SSOLR Pricing
Motor Logic SSOLR Pricing
NEMA Part-winding, Shipping
FVNR, FVR, RVAT Price
Space Shipping Size Two-speed Price Code
Application Price
(Inches) Code
Motor Logic Plus
Motor Logic Base Unit
1–3 $2288. $4576.
Size 1–2 FVNR and FVR $ 196. B C
4–6 3296. 6592.
Size 1-2 2SPD qc 392. F
Motor Logic Plus II
Size 3–4 FVNR, FVR and RVAT 276. B
0 1–3 1900. 3800.
Size 3–4 2SPD and PW qc 552. F C
4–6 2908. 5816.
Size 5 2SPD and PW qc 1544. F
Size 5–6 FVNR, FVR and RVAT 772. F Motor Logic Plus Family SSOLR Communications Adaptors
Motor Logic Feature Base Unit Part-
FVNR,
Overload
Size 1–2 FVNR and FVR 242. C Description FVR, RVAT winding, Space
Relay Type
Pricing Two-speed
(Inches)
Pricing
Size 1–2 2SPD qc 470. F
Modbus® 2-wire
Size 3–4 FVNR, FVR and RVAT 330. C Communications Adapter Part N/C N/C
0 #9999MB22
Size 3–4 2SPD and PW qc 662. F
Size 5 2SPD and PW qc 1852. F Modbus 4-wire
Motor Logic Communications Adapter Part N/C N/C
Size 5–6 FVNR, FVR and RVAT 926. F Plus #9999MB11

q Specify Full Load Current for both speeds. DeviceNet™ Communications $ 200. $ 400.
c Not all configurations are available. Adapter Part #9999DN 0
PROFIBUS Communications
1075. 2150.
Motor Logic Options Adapter Part #CIO-MLP-PR-IO

Space Shipping DeviceNet Communications 200. 400.


Description Application Price Motor Logic Adapter Part #9999DN2
(Inches) Code
Plus II PROFIBUS Communications
Isolated Auxiliary Contact All Starters with 875. 1750.
$ 106. B Adapter Part #CIO-MLPII-PR
(required for fault pilot light) Motor Logic
Auto Reset and Isolated All Starters with Motor Logic Plus Family SSOLR Application Notes:
1152.
Auxiliary contact Motor Logic
• Not available with vacuum starters, Altivar® drives, or with
Remote Reset and Isolated All Starters with
270. 0 Compac™ 6 starters.
Auxiliary Contact Motor Logic D • 120 Vac control power available with individual control power
Overload Light
Requires
270.
transformers or separate source.
Isolated Contact • The Motor Logic Plus SSOLR is provided with a communications
MCC Looping Terminal Kit Size 1 Starters 136. module as standard. Part #9999MB22.

PE4 Discount Prices subject to change without notice.


52 Schedule 12/08
Unit Options
AC Drives

Power Contactor Options (only one allowed)

CB

Drive
Power Circuit Diagram

Integrated Bypass a
(Available with Circuit Breaker Barriered Bypass Barriered Application-Rated
Description Disconnect only. Utilizes (Utilizes NEMA Compac™ 6 Bypass
contactors) (14 A max.)
Telemecanique contactors.)
Shipping Code D (480 V) F (240/208 V) D (480 V) F (240/208 V) D (480 V) F (240/208 V)
208 V 240 V 480 V Space Adder Price Adder Space Adder Price Adder Space Adder Price Adder
1–5 hp 1–5 hp 1–10 hp 12 in. $ 3200. 18 in. $ 4600. 6 in. $ 4600.
7.5–10 hp 7.5–10 hp 15–2 0hp 12 in. 4200. 18 in. 5600.
— — 25 hp VT 12 in. 4200. 18 in. 5600.
15 hp 25 hp CT 9 in. 4200. 18 in. 5600.
15–20 hp 20 hp 30–40 hp 9 in. 5000. 27 in. 8000.
25 hp VT 50 hp VT 9 in. 5000. 27 in. 8000.
25 hp CT 5 in. added 27 inches in
25 hp 50 hp CT 6400. 8000.
30 hp All to width adjacent section
30–40 hp VT 40–50 hp VT 60–100 hp VT 33 inches in
adjacent section
5 in. added for CB
to width 7000. 39 inches in 14000. N/A N/A
30-40 hp CT 40 hp CT 60-75 hp CT
adjacent section
for FS
33 inches in
adjacent section
20 in. added for CB
— — 100 hp CT 15400. 14000.
to width 39 inches in
adjacent section
for FS
125–150 hp 20 in. added 25 in. added
— — 15400. 28000.
All to width to width
20 in. added 25 in. added
— — 200 hp All to width 17000. to width 28000.

• Basic Drive features with isolation • Basic Drive features with isolation and bypass contactors for
and bypass contactors for emergency full speed operation.
emergency full speed operation in • Barriered application-rated Compac™ 6 Bypass uses Telemecanique
same compartment. contactors. NEMA contactors are used on barriered NEMA bypass.
• Telemecanique D or F line • Separate disconnect for drive and bypass can be
contactors are used. operated independently.
• Only available as Circuit Breaker • Drive and bypass starter are enclosed in separate barriered
disconnect common to drive and compartments.
bypass. • Drive and bypass are UL 845 Listed for 100,000 A Short Circuit Current
• Drive and bypass are UL 845 and coordinated for Type 1 protection.
Listed for 100,000 A Short Circuit • Includes AFC-Off-Bypass selector switch, Red
Current and coordinated for Type Push-To-Test “AFC” Pilot Light and Yellow
1 protection. Push-To-Test “Bypass” Pilot Light on bypass control island.
• Includes AFC-Off-Bypass (Non-Push-To-Test used on Compac™ 6)
selector switch, Red Push-To-
Test “AFC” Pilot Light and Yellow
Push-To-Test “Bypass” Pilot Light
on bypass control island.
a Bypass is not isolated from the drive compartment. Both drive and bypass must be removed at the same time.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 53
Unit Options
AC Drives

Power Contactor Options (continued)

CB or Disc CB or Disc

Power
Power Fuse
Fuse
Power Circuit Diagram
Drive

Drive

M M

Description Load Contactor Line Contactor


Shipping Code D (480 V) F (240/208 V) D (480 V) F (240/208V)
208V 240V 480V Space Adder Price Adder Space Adder Price Adder
1–3 hp ALL 1–3 hp ALL 1–10 hp ALL 12 in. $1700. 12 in. $1900.
5 hp ALL 5 hp ALL 15 hp ALL 12 in. 1900. 12 in. 2200.
7.5–10 hp ALL 7.5–10 hp ALL 20 hp ALL
12 in. 2200. 12 in. 2200.
— — 25 hp VT
15–20 hp VT 15–25 hp VT 30–50 hp VT
9 in. 2600. 9 in. 2600.
15–20 hp CT 15–20 hp CT 25–40 hp CT
25–50 hp VT 30–50 hp VT 60–100 hp VT
5 in. added to width 3600. 5 in. added to width 3600.
25–40 hp CT 25–40 hp CT 50–75 hp CT
• Basic Drive features with load contactor • Basic Drive features with line contactor for
for motor isolation. Contactor is open isolating drive from input line.
when drive is not running. • Telemecanique D or F line contactors are
• Telemecanique D or F line used.
contactors are used. • Drive and line contactor are UL 845
• Drive and load are UL 845 Listed for 100,000 Amps Short Circuit
Listed for 100,000 Amps Short Circuit Current.
Current.

Miscellaneous Options
Shipping
Option Space Adder Price Adder
Code

Line Reactors (3% or 5%)


Each line reactor is mounted in the MCC cabinet as a separate unit above the drive 3% 5%
unit and is factory wired to the line side of the drive
1–5 hp, 208/240V or 1–10 hp, 480 V (3 or 5% Impedance) a 6 in. $ 800. $ 960.
7.5–20 hp, 208/240V or 15–40 hp, 480 V (3 or 5% Impedance) a 9 in. 1300. 1600. (3%) C
25 hp VT, 240V or 50 hp VT, 480 V (3 or 5% Impedance) a 12 in. 1800. 2500. (5%) F
25–40 hp CT, 208/240V or 25–40 hp VT, 208V or 30–50 hp VT, 240V or 1200.
50–100 hp CT, 480V or 60–125 hp VT, 480V
Standard
125–200 hp CT or 150–250 hp VT, 480 V 0 in. 2000.
N/C
250–450 hp CT or 300–500 hp VT, 480 V 3000.

Motor Protecting Filters or 5% Output Reactors


Each load filter/reactor is mounted in the MCC cabinet as a separate unit adjacent to
the drive unit and is factory wired to the load side of the drive. Not available on NEMA
Type 12 MCCs.
1–10 hp, 480 V 6 in. 2500. C
(Filters)
15–40 hp, 480 V 9 in. 3600.
E
50–75 hp, 480 V 12 in. 7600. (Reactors)
100–125 hp, 480 V 21 in. (Bottom Mounted only in adjacent section) 9400.
150–200 hp, 480 V 21 in. (Bottom Mounted only in adjacent section) 10600.
F
250–300 hp, 480 V 24 in. (Bottom Mounted only in adjacent section) 11600.
350–400 hp, 480 V 24 in. (Bottom Mounted only in adjacent section) 13200.

100VA Customer Capacity on Drive's 120V Control Transformer


1–3 hp, 208/240 V or 1–3 hp, 480 V with Basic Power Option 3 in. 528.
C
5–100 hp, 480 V or 5–50 hp, 208/240 V 0 in. 528.

300VA Customer Capacity on Drive's 120V Control Transformer


125-500 hp VT or 100-450 hp CT, 480V with Basic Power Option 0 in. 1328. C
a Price and space is applicable to NEMA Type 1, 1A or 3R, Contact the MCC TAG for line reactors in NEMA Type 12 MCCs for these sizes.

PE4 Discount Prices subject to change without notice.


54 Schedule 12/08
Unit Options
AC Drives

Miscellaneous Options (continued)


Price Shipping
Option Space Adder
Adder Code

Extended I/O Cards


(Maximum of 2 can be chosen or 1 if communications card is chosen)
Each option board is pre-installed onto drive inside unit with all customer terminations left unwired
(Type 1A wiring).
Basic I/O Card (VW3A3201) $ 800.
Extended I/O Card (VW3A3202) 1000.
0 in. C
Controller Inside Card (VW3A3501) — mounting only, no programming. Contact the MCC TAG for applications
1100.
requiring programming
3 in. on Basic Power Option for
115 Vac Logic Input Adapter (VW3A3101) Adapts 7 logic inputs for use with user 1–15 hp 480 V
500. F
supplied 115 Vac signals or 1–10 hp, 208/240 V
0 in. for all others

Communications Cards (choose only one)


Each option board is pre-installed and does not include network wiring. Network interwiring within MCC must be
priced separately.
Modbus®/Uni-Telway™ (VW3A3303) 1100.
Modbus Plus™ (VW3A3302) 1500.
PROFIBUS DP (VW3A3307) 1800. C
DeviceNet™ (VW3A3309) 1500.
Ethernet (VW3A3310D) 1700.
Ethernet IP (VW3A3316) 1900. F
0 in.
FIPIO® (VW3A3311) 1500.
C
INTERBUS® (VW3A3304) 1500.
®
LonWorks (VW3A3312) 2000.
Metasys N2 (VW3A3313) 1500.
F
BACnet® (VW3A3315) 1100.
®
Apogee FLNPI (VW3A3314) 1600.

Dynamic Braking Resistors


The use of braking resistors dissipates excess energy generated by the motor whenever the motor functions in
the generator mode as on high inertia loads or machines with a driving load. Resistors are mounted in the MCC
cabinet as a separate unit above the drive unit and is factory wired to the DC bus of the drive. Not available in
NEMA Type 12 MCCs.
1–2 hp, 208/240 V or 1–10 hp, 480 V 6 in. 1200.
3–10 hp, 208/240 V or 15–20 hp, 480 V 9 in. 1900. F
15–20 hp, 208/240 V or 25–40 hp, 480 V 9 in. 2600.

Drive Unit Extenders


1–25 hp VT or 1–20 hp CT, 480 V or 1–10 hp, 208/240 V 3 in. 130.
Provides space added below drive unit for added devices with single door to cover the drive and added space. 6 in. 150.
Available for Basic and Barriered Bypass Power Options only. 12 in. 242.
D
30–50 hp VT or 25–40 hp CT, 480 V or 15–25 hp VT or 15–20 hp CT, 208/240 V 3 in. 130.
Provides space added below drive unit for added devices with single door to cover the drive and added space. 6 in. 150.
Available for Basic and Barriered Bypass Power Options only. 9 in. 242.

Control and Timing Relays


Auto Start Relay without Delay
Provides interposing relay for starting drive in auto mode via customer supplied 120 Vac. For Basic and Barriered 478.
Requires Hand-Off-Auto Selector Switch Bypass units add
3 in. for 1–25 hp VT @ 480 V
Auto Start Relay with Delay C
or 1–20 hp CT @ 480 V,
Provides interposing relay for starting drive in auto mode via customer supplied 120VAC or dry contact. 3 in. for 1–10 hp @ 208/240 V, 1094.
Adjustable time delay for delaying drive start from 1.5-30 seconds is included. Requires Hand-Off-Auto 0 in. for all others
Selector Switch

Prices subject to change without notice. PE4 Discount


12/08 Schedule 55
Unit Options
Altistart Solid-State Starters

Altistart® Unit Power Options


Price Space
Type B-D Adder Ship
Description Soft Start Frame Code
IEC NEMA IEC NEMA
Contactors Contactors Contactors Contactors
D17–D47 $ 600. $ 1000. 15 15
Input Isolation Contactor
(Replaces the standard shunt trip disconnect. Standard D62–C11 1000. 1800. 18 15
feature if Reversing or Full Voltage Bypass is chosen.)
As an option, MCC Soft Start units can include an input C14–C17 1800. 3000. 18
12 (5 in. added
contactor to isolate the Soft Start in case of a fault condition to width)
instead of a shunt trip disconnect. The input contactor also C
opens when the motor is not in use. This provides 10 in. added to width for 20 in. added
C21–C32 2700. 6700. CB version only to width
protection from voltage transients when the electronics are
most susceptible to damage. Control power is maintained
after the input contactor is opened so fault diagnostics are C41–C66 (IEC)
20 in. added
available. or 4000. 13000. 0
to width
C41–C59 (NEMA)
D17–D47 1000. 1400. 15 27
Integrated Full Voltage Bypass Starter
(Requires Input Isolation Contactor) D62–C11 1600. 2400. 18 27
As an option, MCC Soft Start units can include a full voltage
bypass to allow emergency full voltage starting of the motor C14–C17 2600. 3800. 18
12 (5 in. added
in case the Soft Starter is unable to be used. This feature to width)
includes necessary control and power circuitry to start the C
motor with full voltage using a bypass enable/disable 10 in. added to width for 20 in. added
C21–C32 3600. 7600.
selector switch. A Class 20 overload relay is provided to CB version only to width
protect the motor in the bypass mode. The bypass
contactor also acts as a shorting contactor in the soft start C41–C66 (IEC) 20 in. added
mode. Not available with Reversing Capability. Or 5400. 14400. 0
to width
C41–C59 (NEMA)
D17–D47 1200. 15
D62–C11 2000. 18
Reversing Capability
(includes Input Isolation Contactor) C14–C17 3600. Consult 18 Consult C
Not available with NEMA Contactors or Full Voltage Factory Factory
Bypass. C21–C32 5400. 10 in. added to width for
CB version only
C41–C66 8000. 20 in. added to width

Altistart Unit Control Options


Price Space
Description Ship Code
Type B-D (Inches)
1.5-30 sec. start delay $1094. E
Emergency Off push button, maintained contact. Requires Shunt Trip on disconnect 280. C
0
Current Meter–Analog, 2.5 in. panel type, 0-200% of nominal motor current 1384. E
Elapsed Time Meter 480. C

Auxiliary Electrical Interlocks


Run contacts, 1 NO, 5A @ 120 Vac (8501 Type R relay)
Bypass Run contacts, 1 NO, 5A @ 120 Vac (8501 Type R relay). Requires Integrated Full Voltage Bypass.
528. 0 C
Auto Mode contacts, 1 NO, 5A @ 120 Vac (8501 Type R relay). Requires Hand-Off-Auto Switch
Fault contacts, 1 NO, 5A @ 120 Vac (8501 Type R relay)

PE4 Discount Prices subject to change without notice.


56 Schedule 12/08
Unit Options

Unit Extenders
Unit extenders are used to provide additional component mounting space within a unit. Only one unit extension is recommended per unit. Total unit
size cannot be increased beyond 72 in. Space requirements and prices shown for the modifications in this guide already include the unit extension.

Description Application Price Space (Inches) Shipping Code


3 in. Unit Extender All Plug-In Units $132. 3
6 in. Unit Extender All Plug-In Units 148. 6
9 in. Unit Extender All Plug-In Units 194. 9
12 in. Unit Extender All Plug-In Units 242. 12
15 in. Unit Extender All Plug-In Units 302. 15
B
18 in. Unit Extender All Plug-In Units 364. 18
21 in. Unit Extender All Plug-In Units 424. 21
24 in. Unit Extender All Plug-In Units 482. 24
30 in. Unit Extender All Plug-In Units 594. 30
36 in. Unit Extender All Plug-In Units 704. 36

Fusible Switch Options


Description Application Price Space (Inches) Shipping Code
30–600 A Fusible Switches
Class R Fuse Clips a N/C 0
Size 1-6 Fusible Starters B
Class J Fuse Spacing 30–400 A Fusible Switches N/C 0
(Standard with Compac™ 6 Fusible starters) 600 A Fusible Switches N/C 0 F
Size 1, 5, 6 Fusible Starters N/C 0
Next Larger Size Class J Fuse Clips a Size 2, 3 Fusible Starters $150. 6 G
Size 4 Starters 242. 12
Next Smaller Size Fuse Clips a Size 1–6 Fusible Starters N/C 0 D
Key Interlock (Single Cylinder) a Per Lock/ Per Switch 968. 0 G

a Not available on Compac™ 6 starters.

Factory Installed Fuses


Prices listed are for a set of three (3). Specify exact fuse size when ordering.

Type Class FRN/RK5 KTN/RK1 LPN/RK5 FRS/RK5 KTS/RK1 LPJ/J LPS/RK5 KRP/L
Shipping Code
Max. Fuse Size 250 Volts 600 Volts

30 $ 116. $ 204. $ 192. $ 204. $ 264. $ 292. $ 268. —


60 164. 476. 444. 344. 568. 504. 568. —
100 372. 1020. 1040. 712. 1216. 996. 1280. —
200 820. 1014. 2156. 1424. 2292. 1420. 2156. —
400 1476. 4052. 4296. 2848. 4564. 2848. 4296. — F
600 2260. 5268. 5296. 4096. 6216. 4076. 6536. —
1200 — — — — — — — $ 6680.
1600 — — — — — — — 8160.
2000 — — — — — — — 10680.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 57
Unit Options

Circuit Breaker Options


Space Shipping
Description Application Price
(Inches) Code
Substitute L-interrupting circuit breaker for J-interrupting H-frame starters $ 300.
circuit breaker. (Part-Winding Starters require two circuit
breakers.) J-frame starters 800.
B
Substitute thermal-magnetic circuit breaker for Motor 0
All starters (Include actual hp information) 160. Deduct.
Circuit Protector.
50 °C rise breaker All (non-UL) 100. F
Key interlock (Schneider Electric brand) a Per lock on any device 968. G
Type A Type B-D
SPDT 126. 316.
Operating mechanism interlock C
DPDT a 194. 384.
C (Mains/
Branches)
Shunt trip (120 Vac) Any unit with a circuit breaker 460. 710. 0
E (Starters)
Shunt trip (24 Vdc) Any unit with a circuit breaker 460. 710. F
Undervoltage trip Any unit with a circuit breaker 460. 710.
15-600 A main circuit breaker 9
200-400 A main switch
800 A main circuit breaker
Phase failure relay, Type MP SPDT (Form C) for 12 E
1200 A (80%) main circuit breaker 860. 1050.
Main C/B or Switch (See page 35.)
600-800 A main switch
100-1200 A bottom incoming main switch 15

All other mains


Any unit with a circuit breaker
1 Form C contact 256. 506.
Auxiliary switch q
2 Form C contacts (PowerPact® only) 512. 762. D
3 Form C contacts (PowerPact M, P, and R only) 768. 1018.
Alarm switch q Any unit with a circuit breaker (1A or 1B switch) 256. 506.
0
Overcurrent trip switch (SDE) q PowerPact circuit breaker (1 Form C contact) 356. 606.
Electrical operator (two-step, stored energy). Includes E
spring-charging motor and terminals for remote contact 875. 1375.
control of open/close operation
Mains/Branches with PowerPact P-frame circuit
Electrical operator with Modbus® communications breaker
(two-step, stored energy). Includes spring-charging
motor and actuators for serial communication control of 2125. 2375. H
open/close operation
a Not available on Compac™ 6
q Low level switches for switching very low loads are available on PowerPact H/J/M/P or R-frame breakers. Add $100. to price indicated for low level switches.

PE4 Discount Prices subject to change without notice.


58 Schedule 12/08
Unit Options

Circuit Breaker Micrologic® Electronic Trip Unit Options


Space Shipping
Description Application Price
(Inches) Code

350-600 A Breakers (L-frame)


Standard Function LX substituted for LA/LH/LI LSI c $3346.
Full Function LE substituted for LA/LH LSI c 4904.
®
700-2500 A Circuit Breakers (PowerPact P- and R-frame)
Standard E
5.0 LSI 1200
Ammeter
5.0A LSI 2625.
6.0A LSIG 4375.
Trip Unit Power Supply (recommended for Ammeter Trip Unit) 1600.
Power
5.0P LSI 8475. 0
C
6.0P LSIG 11825.
Trip Unit Power Supply (provided standard for Power Trip Unit) N/C
Harmonic
5.0H LSI 12225.
6.0H LSIG 13975.
Trip Unit Power Supply (provided standard for Harmonic Trip Unit) N/C E
®
Modbus Breaker Communications Module (BCM) installed and
A Trip Unit only 2600.
unwired (Includes 24vDC communications power supply)
Modbus Breaker Communications Module (BCM) unwired
P or H Trip Unit 1600.
(Includes 24vDC communications power supply)
®
Wiring to MCC Modbus network (adds network cable to main/ Intelligent MCC or Transparent Ready
800.
branch unit) MCC H
Communications for shunt trip A, P or H trip unit 400.
c Ground Fault tripping functions can be added to these trip units. See Ground Fault options below.

Ground Fault Options


Ground Fault Space Shipping
Description Application Price
Type (Inches) Code
Size 1–2 Starter $1200. 6
Size 3 Starter 1244. 9
GA
Size 4–5 Starter 1292. 12
Size 6 Starter 1050. 0
Order
appropriate
Micrologic G
Size 6 Autotransformer 0. 0
electronic trip
unit option
(6.0A, P or H)
15–250 A Branch Circuit Breaker a 2096.
GFM
Ground Fault Protection (Zero Sequence) 110–250 A Main Circuit Breaker 3036. 6
Pricing Instructions: Select standard main or branch unit,
then add the Ground Fault price to the right for the unit selected. 200 A Main/Branch Fusible Switch GA 2096.
Add price for upgrading to Micrologic trip units on PowerPact M,
P, or R-frame breakers. 300–600 A Main or Branch Circuit Breaker LX MX C/B 4198.
0 F
300–600 A Main or Branch Circuit Breaker LE ME C/B 5198.
0 (3 W)
600–800 A Main or Branch Switch 12 (4 W)
1000-1200 A Branch Switch or Top
Order 0
Incoming Main Switch
appropriate 0. (3 W)
Micrologic 0 (3 W)
1000-1200 A Bottom Incoming Main Switch E
electronic trip 12 (4 W)
unit option 4198. (4 W)
800-1200 A Main or Branch C/B (80%) (6.0A, P or H) 0 (3 W)
800 A Main or Branch C/B (100%) 15 (4 W)
1200 A Main or Branch C/B (100%) 0
1600-2500 A Main C/B or Switch
a Not available on Compac™ 6.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 59
Unit Options

Wiring Options
Description Application Price Space Shipping
(Inches) Code
Additional Terminal Blocks All Starters $ 20 0 E
NOTE: Max. 20 control terminals per unit. All Starters—Wired (per Terminal Point) 62. 0 F
Control Power Transformer Leads
X1 and X2 wired to the control terminal block. All Starters 124. 0 B
(N/C on Industrial Package)
Power Terminal Blocks Size 1–2 Starters 76.
0 C
(Will reduce max. Control from 20 to 12) Size 3 Starters 222.
#14 AWG Type MTW N/C 0 B
Starter Control Wiring; Size and Type #12 AWG Type MTW 48.
0 D
(price adder per starter unit) c #14 AWG Type SIS 82.
#12 AWG Type SIS 112. 0 G
Standard Wire Labels—Plastic Sleeve All Starter Control Wiring 416. 0 D
(price adder per starter unit) Schneider Electric Numbering
Custom Wire Labels—Plastic Sleeve All Starter Control Wiring 508.
(price adder per starter unit) User Defined (13 Characters Max.) 0 G
Ring Tongue Terminalsf All Starter Control Wiring 508.
(price adder per starter unit)
Main Lug Compartments 0 D
Size 1-4 Starters tc 0 G
15–150 A Main/Branch Circuit Breaker c 3 Cq
300.
175–250 A Main/Branch Circuit Breaker c 0 Cq
Copper Crimp Lugs
(For customer connections only; cable sizes must be provided) 15–100 Branch Fusible Switch c 3
G
110–225 A Main/Branch Fusible Switch 6
600-800 A Main Switch 12
Cq
800 A Main or Branch Circuit Breaker 750. 15
All Other Units c 6 G
Aluminum Lug for 600kcmil Cu or Al cable or 750kcmil compacted Al cable (2/phase, AL800P7K kit)
700-800 A Circuit Breaker 15
300. F
600-800A Main Switch 12
Aluminum Lug for 600kcmil Cu or Al cable (3/phase, AL1200P6KU kit)
1000-1200A Circuit Breaker (80% rated) 15
1000-1200A Circuit Breaker (100% rated) 0 F
475.
Main/Branch Mechanical Lug Alternatives c 1000-1200 A Top Incoming Main Switch
1000-1200 A Bottom Incoming Main Switch 12
Aluminum Lug for 750kcmil compacted AL cable (3/phase, AL1200P7KU kit)
1000-1200A Circuit Breaker (80% rated) 15
1000-1200A Circuit Breaker (100% rated) 0 F
625.
1000-1200 A Top Incoming Main Switch
1000-1200 A Bottom Incoming Main Switch 12
Special Wire Colors—3 max. (price adder per starter unit) All Starter Control Wiring 100. 0 G
c Not applicable to Compac™ 6, Altivar®, or Altistart® units.
f Provided where possible and allowed by UL procedure.
t Not UL Listed.
q Shipping Code is for standard Burndy Type Copper Crimp Lugs as shown in the table below. Custom lugs or different wire sizes are “G” shipping code.

Optional Burndy Type Copper Crimp Lugs


Circuit Breaker Frame Maximum Amps Burndy Crimp Lug Lugs Per Phase
Lug Wire Range
60 #6–1/0 AWG Cu
H
150 #4–2/0 AWG Cu
1
150 #4–2/0 AWG Cu
J
250 2/0–300 kcmil Cu
P (molded case switch) 600 4/0–500 kcmil Cu
2
M and P (circuit breakers/switches) 800 500–750 kcmil Cu

NEMA/EEMAC Type B-T Wiring NEMA/EEMAC Type C Wiring


To obtain pricing for NEMA/EEMAC Type B-T wiring, select Type B-D To price a MCC with Type C wiring, price all units as Type B-D (standard
wiring from the Combination Starter Unit Tables (pages 21-34) and add wiring), add a master terminal compartment (see page 64) per section.
power terminal blocks from the wiring options table above to each unit.

Description Application Price (Per Unit) Space Shipping


NEMA/EEMAC Class 2 Wiring (In.) Code
Size 1 and 2 Control Only $460.
All prices in this guide are based on NEMA/EEMAC Class 1 wiring. To Starters Control and Power 518.
price a MCC with Class 2 wiring, price as Class 1, Type B or Type C,
NEMA/EEMAC Size 3 Control Only 460.
and add $520. per Class 2 wired unit. This will give the Class 2 total 0 F
Type C Wiring Starters Control and Power 682.
price. For more details on Class 2 wiring of Automation Components, Size 4 and 5 Control Only 460.
see page 72. Starters Control and Power N/A

PE4 Discount Prices subject to change without notice.


60 Schedule 12/08
Miscellaneous Units
AccuSine Power Correction System
General Information
The AccuSine® Power Correction System (PCS) is an active harmonic The Model 6 MCC AccuSine package includes:
filter (AHF) which actively injects opposite harmonics current on the • 50 A or 100 A rated model Accusine PCS for 208–480 V.
source side of the load and it:
• Door-interlocked disconnect and fusing.
• Decreases harmonic related overheating of cables, switchgear, and • Door-mounted display (HMI) for programming and monitoring.
transformers. • Suitable for use in 100 kAIC rated MCCs
• Reduces downtime caused by nuisance thermal tripping of protective • UL/cUL Listed.
devices.
• Rated for NEMA 1 or NEMA 1 Gasketed MCC Enclosures. NEMA 12
• Increases electrical network reliability and reduces operating costs. or NEMA 3R are not available.
• Corrects to the 50th harmonic; reduces harmonics level to meet • Two current transformers for installation by contractor at the MCC
IEEE 519 at the MCC main incoming power connection. main incoming cables. Three CTs are supplied when single phase
• Cost effective approach to groups of harmonic loads and as an loads are present.
alternative to multi-pulse drives. • Up to five multiple units can be connected in parallel to increase
When installed in the MCC, the AccuSine PCS will compensate for compensation up to 500 A of harmonic current compensation.
harmonic loads within and fed by the MCC. This is an essential function • Standard MCC bus and enclosure depth allow the active filtering to
as MCCs continually incorporate more and more solid state components be retrofitted onto the MCC for future expansion of harmonic
such as AC drives, soft starts, and PLCs, which increase the potential compensation.
for power quality issues.

Typical MCC AccuSine Installation

Upstream
Electrical MCC Enclosure
Network

Active
Filter
VFD VFD

Uncorrected Loads M M M M

Corrected Loads

Accusine PCS Sizing


A harmonic study is not required to select the size of the AccuSine PCS installation, because when AccuSine PCS is installed it becomes a lower
impedance for harmonics than the existing power supply. Unlike passive devices, AccuSine PCS is easy to apply and cannot be overloaded. For proper
sizing contact the Power Quality Correction Group or visit the Power Quality Correction website for downloadable sizing software. To expedite the
product selection process have a single line diagram and/or details of the application including sizes of transformers, non-linear and linear loads, and
any existing filters and capacitors.

AccuSine Power Correction System for Model 6 MCC


Total Current Disconnect Switch Voltage Rating Shipping
Price Space (Inches)
(RMS Amps) (Amps) (Volts) Code
50 100 $105600. 72
208/240/480 (20 W x 20 D) G
100 150 124800.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 61
Miscellaneous Units

Single Phase Distribution Transformers 120/240V Secondary


Distribution transformers are provided with primary circuit breaker or NOTE: 5 kVA and 10 kVA transformers are available in multiple section
fusible switch. 5 kVA and 10 kVA transformers may be mounted in a shipping splits. All other transformers listed are bottom mounted in a
standard 20 in. wide x 15 in. or 20 in. deep section. 15 kVA and 25 kVA single shipping split. Shielded Isolation Transformers are available, and
transformers must be mounted in a 20 in. wide x 20 in. deep section. other primary voltages can be supplied. Contact the MCC TAG for price,
150 °C temperature rise transformers are supplied as standard. space, and delivery.

Disconnect kVA Rating Disc. Amps Price Space (Inches) Shipping Code
0.5 kVA 15 $ 2400. 6 E
1kVA 15 3200. 12
480 V 1.5 kVA 15 3200. 15
Primary 5 kVA 15 3590. 21q
Circuit Breaker 10 kVA 30 4380. 21q B
15 kVA 40 10960. 36
25 kVA 60 12300. 36
0.5 kVA 15 2400. 6 E
1 kVA 15 3200. 12
240 V 1.5 kVA 15 3200. 15
Primary 5 kVA 30 3590. 21q
Circuit Breaker 10 kVA 50 4380. 21q B
15 kVA 70 10960. 36
25 kVA 125 12300. 36
0.5 kVA 15 2400. 6
1 kVA 15 3200. 12
600 V 1.5 kVA 15 3200. 15
Primary 5 kVA 15 3590. 21q F
Circuit Breaker 10 kVA 20 4380. 21q
15 kVA 30 10960. 36
25 kVA 50 12300. 36
0.5 kVA 15 2300. 6 E
1 kVA 15 3100. 12
480 V 1.5 kVA 15 3100. 15
Primary 5 kVA 15 3556. 21q
Fusible Switch 10 kVA 25 4132. 21q B
15 kVA 35 10960. 36
25 kVA 60 12300. 36
0.5 kVA 15 2300. 6 E
1 kVA 15 3100. 12
240 V 1.5 kVA 15 3100. 15
Primary 5 kVA 25 3556. 21q
Fusible Switch 10 kVA 45 4132. 21q B
15 kVA 70 10960. 36
25 kVA 125 12300. 48
0.5 kVA 15 2300. 6
1 kVA 15 3100. 12
600 V 1.5 kVA 15 3100. 15
Primary 5 kVA 10 3556. 21q F
Fusible Switch 10 kVA 20 4132. 21q
15 kVA 30 10960. 36
25 kVA 50 12300. 36
q Unit mounted transformers are available in 5 kVA and 10 kVA ratings. 30 in. space required and shipping codes is changed to D.

Three-Phase Distribution Transformers 208Y/120V Secondary


Distribution transformers are provided with primary circuit breaker or NOTE: All transformers listed must be bottom mounted in a single
fusible switch. 150 °C temperature rise transformers are supplied as shipping split. Shielded Isolation Transformers are available and other
standard. Three-phase distribution transformers must be located in primary voltages can be supplied. Contact the MCC TAG for price,
20 in. deep sections. space, and delivery.

Disconnect kVA Rating Disc. Amps Price Space (Inches) Shipping Code
9 kVA 15 $ 6790. 30 F
480 V
15 kVA 20 10250. 30
Primary
30 kVA 40 14450. 36
Circuit Breaker
45 kVA 60 20470. 36a
9 kVA 30 6790. 30 B
240 V
15 kVA 40 10250. 30
Primary
Circuit Breaker 30 kVA 90 14450. 36
45 kVA 125 20470. 36a
9 kVA 15 6790. 30
600 V
15 kVA 20 10250. 30
Primary F
30 kVA 40 14450. 36
Circuit Breaker
45 kVA 50 20470. 36a
480 V 9 kVA 15 6790. 30
Primary 15 kVA 20 10250. 30
30 kVA 40 14450. 36
Fusible Switch
45 kVA 60 20470. 36a
B
9 kVA 25 6790. 30
240 V
15 kVA 40 10250. 30
Primary
30 kVA 80 14450. 36
Fusible Switch
45 kVA 125 20470. 48a
9 kVA 10 6790. 30
600 V
Primary 15 kVA 20 10250. 30
F
Fusible Switch 30 kVA 35 14450. 36
45 kVA 50 20470. 36a
a Requires 25 in. wide structure.

PE4 Discount Prices subject to change without notice.


62 Schedule 12/08
Miscellaneous Units

Distribution Panelboards
Panelboards are provided with space for branch circuit breakers. All NOTE: NF panelboards must be located in the top of the section.
panelboards are provided with a main circuit breaker. The 3-Phase, Ratings: 1-Phase NQ = 120/240 V
Type NQ 30 circuit is also available with a Main Lug. Copper bus is 3-Phase NQ = 240 V
standard. 3-Phase NF = 277/480 V
NOTE: NQ 18- and 30-circuit panelboards utilize back-fed main units,
thus reducing the available pole spaces for circuit feeds.

Space Shipping
Unit Type 1-Pole Spaces Main Amperes Interrupting Rating Price
(Inches) Code

1-Phase 18 100 N/A $ 952. 27


B
Type NQ 42 225 N/A 2364. 51
18 100 N/A 1470. 27 G
3-Phase
30 100 N/A 1560. 33
Type NQ B
42 225 N/A 2552. 51
Main Lug 30 100 N/A 1162. 33c G
30 — 65 kAIC 3224. 45q

3-Phase 30 N/A 100 kAIC 5520. 45q


C
Type NF 42 N/A 65 kAIC 5702. 57q
42 N/A 100 kAIC 11262. 57q
c Main Lug.
q 25 in. wide structure.

Factory Installed Panelboard Branch Circuit Breakers


The branch circuit breakers below are rated for 10,000 AIR at the voltage listed. Higher interrupt ratings are available.

Branch Circuit Price Shipping


Panelboard Type Poles Amps
Breaker Type Plug-on Bolt-on Code
10–60 $ 54. $ 70.
1
70 126. 140.
10–60 126. 158.
QO/QOB 2 70–100 354. 428.
120/240V
110–125 762. 896.
NQ
(QOB branch circuit breakers are standard, 10–60 442. N/A
unless otherwise noted) 3
70–100 654. N/A
QO/QOB – GFI 1 15–30 436. 442.
120/240V 2 15–60 774. 794.
QO/QOB 15–60 358. 428.
2
240V 70–100 562. 654.
15–60 268.
1
70 538.
15–60 684.
EDB 2 70–100 1352.
(Bolt-on Only) 110–125 4092.
15–60 1196. D
3 70–100 1626.
110–125 5090.
15–60 456.
1
70 914.
NF 15–60 1026.
EDB branch circuit breakers are standard, unless
otherwise noted) EGB 2 70–100 2028.
(Bolt-on Only) 110–125 6138.
15–60 1794.
3 70–100 2440.
110–125 7636.
15–60 728.
1
70 1464.
EJB 15–60 1574.
2
(Bolt-on Only) 70–100 1555.
15–60 1196.
3
70–100 1626.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 63
Miscellaneous Units

Empty Mounting Units Unwired Master Terminal Compartment


Includes a removable undrilled unit and a hinged door to provide space (For NEMA/EEMAC Type C wiring, see page 60).
for customer mounted devices. Unit dimensions are 13.85 in. wide by Includes a removable 12 in. unit, hinged door, unwired control and
9.5 in. deep. Height is dependent on unit selected. power terminal blocks, and mounting provisions. Compartment may be
Empty mounting units may be used in 20 in. wide by 15 in. or 20 in. deep located anywhere in a 20 in. wide by 15 in. or 20 in. deep section.
sections. Price includes mounting unit, but space must be included in layout and
in pricing number of sections.
Unit Height Shipping
Price
(Inches) Code
Space Shipping
Terminal Provisions Price
6 $ 708. (Inches) Code
9 738. 100 Control Points $1344.
12 762. 100 Control Points and 15 Power Points 12 D
1546.
15 790. 70 Control Points and 30 Power Points
18 810.
21 836. Blank Doors
24 858. Factory-assembled MCC orders are automatically provided with the
proper number of blank covers to fill any unused space in each section.
27 884. B
Future Prepared Space may be provided if desired; to provide Future
30 912.
Prepared Space, add the desired number and size required.
33 936.
Blank doors are required to fill prepared space when rearranging plug-in
36 960. units in an existing motor control center.
39 996.
42 1010. Prepared Space Height Shipping
(Inches) Price Code
45 1050.
48 1062. 3 $ 58.
6 58.
Full Section Empty Mounting Units (Relay Section) 9 70.
Consists of a removable undrilled mounting pan and a full height door 12 82.
on structure for customer mounted devices. The section does not 15 96.
contain vertical bus or a vertical wireway. The section cannot be
18 112. B
modified to accept plug-on units. Horizontal bus is supplied to allow feed
through to additional MCC sections. 21 126.

NOTE: Relay section price does not include enclosure structure charge. 24 140.
Add 72 in. to space requirements to charge out section. 27 154.
Panel height: 68 in. 30 168.
Panel depth (clearance from panel to door) 36 182.
11.7 in. (15 in. deep section)
16.7 in. (20 in. deep section)

Section Panel Space Shipping


Price
Width Width (Inches) Code
20 in. 18.13 in. $1460.
25 in. 23.13 in. 1958.
72 B
30 in. 28.13 in. 2200,
35 in. 33.13 in. 2660.

Omit horizontal bus for listed sections a


--- --- N/C 0 D

3-point door latch


--- --- 686. 0 F
a UL845 does not recognize sections without horizontal bus, therefore these
sections can not be UL Listed.

PE4 Discount Prices subject to change without notice.


64 Schedule 12/08
Miscellaneous Units

Power Factor Correction Capacitors Selection and Pricing—208 V and 240 V


Prices shown are for installed units, including mounting and wiring for
Power Factor Correction Capacitors listed are environmentally safe and
the individual motor connection.
include fuses for protection of the capacitor. These capacitors include
discharge resistors as required by the NEC. Prices shown are for NOTE: To select unit type, determine kVAR rating from table below.
installed units, including mounting and wiring for individual motor Match kVAR rating to last digits listed on unit type. Use Shipping Code
correction. Capacitors are mounted directly below the F for all power factor correction capacitors.
corresponding starter and are connected between the starter
contactor and overload relay. Installation of capacitors does not affect
kVAR Rating Price Space
normal selection of overload thermal units, starters, or disconnects.
208V 240V With Lights (inches)
Do not use capacitors on controllers subject to plugging or jogging. It is
recommended that only Full Voltage Non-Reversing (FVNR) starters be — 1 $ 2374.
1 1.5 2462.
provided with power factor correction capacitors. Capacitors can be 1.5 2 2554.
applied to other types of starters, but auxiliary contactors are often 2 2.5 2646.
2.5 3 2718.
required. Some types of starters are not compatible with individual motor 3 4 2840.
correction. Contact the MCC TAG for details or application assistance. 4 5 2942. 6
5 6 3120.
Selection and Pricing—480 V and 600 V — 7 3236.
— 7.5 3290.
Prices shown are for installed units, including mounting and wiring for — 8 3900.
the individual motor connection. 6 — 4414.
— 9 4558.
NOTE: To select unit type, determine kVAR rating from table below.
7 — 4670.
Match kVAR rating to last digits listed on unit type. Use Shipping Code 7.5 10 4720.
F for all power factor correction capacitors. — 11 4790.
9 — 4902.
— 12 4940. 6
kVAR Rating Price Space — 12.5 4980.
480 V 600 V With Lights (inches) 10 — 5134.
1 — $ 2298. — 15 5338.
— 17.5 7014.
1.5 1 2340.
2 1.5 2380. 11 — 7014.
2.5 2 2422. 12.5 — 7082.
3 2.5 2462. 15 20 7290.
17.5 22.5 7634. 12
4 3 2558. 20 25 8806.
5 4 2650. — 27.5 9382.
6 5 2724. — 30 9808.
7 — 2790.
22.5 — 10500.
7.5 — 2816. 25 32.5 11600.
8 — 2844. — 35 12030.
9 6 2892. 27.5 37.5 12456. 18
10 7.5 2946. — 40 13628.
— 42.5 14178.
11 — 2994. — 45 14704.
12 — 3038.
12.5 — 3068. Capacitor Sizing—480 V
6
13.5 10 3144.
Size capacitors (in kVAR) to the particular motor loads to be corrected.
11 3188.
12 3226. If motor characteristics are not available, the values in the last column
15 provide approximate sizing.
12.5 3296.
15 3384.
16 — 4312.
Horsepower

17.5 — 5594. RPM – NEMA/EEMAC Design Approx.


18 — 4432. 3600 1800 1200 900 720 600 Value When
20 16 4544. Motor Data
B B C B C D B C B B Is Not
22.5 17.5 4680. Available
25 18 4790.
20 4902. 3 1.5 1.5 1 2 1 1 3 2 3 4 1.5
27.5 5 2 2.5 2 3 2 2 4 2 4 5 2
22.5 4980.
25 5062. 7.5 2.5 3 3 4 3 2 5 4 5 6 2.5
30 27.5 5222. 10 4 4 4 5 4 3 6 4 7.5 8 3
30 5342. 15 5 5 5 6 5 5 7.5 5 8 10 4
32.5 — 6534. 20 6 6 5 7.5 5 6 9 6 10 12.5 5
35 — 6656. 25 7.5 7.5 6 8 6 6 10 6 12.5 17.5 7
37.5 — 6786. 30 8 8 7.5 10 7.5 10 15 9 15 20 9
— 6908.
40 40 12.5 15 10 15 10 12 17.5 12 20 25 10
32.5 6998.
50 15 17.5 12 20 12 15 22.5 15 22.5 30 12
— 7042.
42.5 60 17.5 20 17.5 22.5 17.5 18 25 18 30 35 15
35 7110.
— 7178. 12 75 20 25 20 25 20 22.5 30 22.5 35 40 18
37.5 7300. 100 22.5 30 27.5 30 27.5 30 35 27.5 40 45 22.5
45
40 7520. 125 25 35 35 35 35 37.5 40 37.5 45 50 27.5
45 7720. 150 30 40 37.5 40 37.5 45 50 45 50 60 32.5
50 — 8306. 200 35 50 45 50 45 60 70 60 70 90 40
— 9168.
250 40 60 55 60 55 70 80 70 90 100 50
60 50 9978.
300 45 70 65 75 65 75 100 90 100 120 55
60 11028.
350 50 75 — 90 — — 120 — 120 135 65
70 — 11386.
18 400 75 80 — 100 — — 130 — 140 150 70
80 — 12916.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 65
Miscellaneous Units
Transparent Ready
PowerLogic® Ethernet Gateways
The PowerLogic devices listed below provide an interface between Ethernet and Modbus® devices. In addition to the high-speed communications, the
Ethernet connectivity opens up information access via standard web browsers. The gateway can connect with up to 64 Modbus or PowerLogic devices.
Each unit includes the gateway, control power disconnect, fused control power transformer and DC power supply. Connection cables to the Modbus
network or Ethernet network are not included.

Price Space Shipping


Description Application
(Type B-D Wiring) (Inches) Code
PowerLogic Ethernet Gateway with one UTP Ethernet Port (10/100 Mbps),
EGX100 $ 8000.
one RS-485 serial port, and one RS-232 serial port.
PowerLogic Ethernet Gateway with one UTP Ethernet Port (10/100 Mbps), a serial
EGX300 port configurable for RS-485 or RS-232, and memory for storing web pages, 11200.
instruction bulletins, equipment drawings, etc. 9 C
PowerLogic Ethernet Gateway with one UTP Ethernet Port (10/100 Mbps), one
Fiber optic port (100 Mbps), one RS-485 serial port, a second serial port
EGX400 11700.
configurable for RS-485 or RS-232, and 8 MB of memory for storing web pages,
instruction bulletins, equipment drawings, etc.

Transparent Ready® Equipment Configurations


Motor Control Center Transparent Ready options provide the ability to access pre-programmed/pre-linked web pages in the MCC equipment. This
allows the customer to quickly commission and view a wide range of process data using web browser software. The MCC can be pre-tested and pre-
wired at the factory with the Ethernet connection ready for the customer’s network.
The Transparent Ready levels below offer web page choices for real time data, enhanced graphics and reporting capability.
NOTE: Prices do not include the Ethernet Switches (see Ethernet Switches), communication cards, TeSys® T Motor Management Controller,
Communication Cables, or Interwiring Charges.

Shipping
Description Application Price
Code

TR1—Essential
Web Enabled and Factory Configured for Ethernet Mains Monitoring Only q $ 5200.
H
5 Web Pages of Real Time Data Using Web-Generator 1 (WG-1) c Main + Downstream Devices Monitoring s 5200.

TR2—Deluxe
Features of TR1 Plus Graphical Pages for use on EGX system
supported software: Web-Generator 2 (WG2) f Main + Downstream Devices a 17800. H

q Requires PowerLogic Power Meter selected on the MCC Main. Requires an ECC card on the Circuit Monitor (if selected) or an EGX Gateway with Ethernet switches.
s Requires at least one Modbus compatible device (TeSys T Motor Management Controller, PowerLogic Meter, Altivar® 61/71 AC drive, or Altistart® Soft Start). Requires
an ECC21 card on the Circuit Monitor (if selected) or an EGX Gateway with Ethernet Switches.
a Requires at least one Modbus compatible device (TeSys T Motor Management Controller, PowerLogic Meter, Altivar 61/71 AC drive, or Altistart Soft Start). Requires an
EGX400 Gateway with Ethernet switches.
c Web-Generator (WG-1) software provides basic informational pages for use with the PowerLogic ECC or EGX Ethernet Gateway.
f Web-Generator (WG-2) software provides advanced informational pages for use with the PowerLogic EGX Ethernet Gateway.

Gateway Ethernet Switches


A gateway Ethernet switch serves as a hardware interface between an EGX Ethernet gateway and other Ethernet connections such as the customer's
Ethernet network outside the MCC, and the programming port on the outside of the MCC door. A choice of switch types are available, depending on
the hardware (copper wire or fiber optic) the customer would prefer. For Transparent Ready MCCs, the default selection is 10/100 Mbps if no other
choice is made.
NOTE: The Ethernet switches and bulkhead port connector are not provided unless a Transparent Ready level is requested. For customers requesting
network provisions only, the gateway is provided with no switches.

MCC List Price Shipping


Description of Part Space Adder
Adder Code

10/100 Mbps Ethernet RS485 Switches


(Available with EGX Gateways only)
Provides five (5) 10/100 Mbps twisted pair (RJ-45 connectors) ports for the customer to connect their Ethernet factory 0 $4576. C
network and mounted programming port to the EGX Gateway(s)

Fiber Optic Interface Switches


(Available with EGX Gateways only)
Provides four (4) 10/100Mbps twisted pair (RJ-45 connectors) ports and one 100Mbps fiber optic port (100 Base-FX,
Duplex SC connector) for the customer to connect their Ethernet factory network and mounted programming port to the 0 9248. C
EGX Gateway(s).
NOTE: An Ethernet Switch is required for use with TR-1 or TR-2. If no switch is chosen by the customer, the 10/100 Mbps Ethernet RS485 switch for copper wire should be
priced with EGX on TR-1 or TR-2.

PE4 Discount Prices subject to change without notice.


66 Schedule 12/08
Miscellaneous Units
High Resistance Ground
High Resistance Ground Unit
The High Resistance Ground Unit offers ground fault control and monitoring for power systems using ungrounded delta or wye transformer secondaries.
The Model 6 Motor Control Center high resistance ground unit can be applied to 480 V and 600 V ungrounded delta and wye, 50/60Hz systems. The
high resistance ground unit is available for both 3-phase, 3-wire wye and delta power systems. The Model 6 high resistance ground unit facilitates a
controlled, sequential process shutdown, thereby reducing the adverse affects resulting from an uncontrolled shutdown.
Standard Package Features:
• Resistor bank limits overvoltages by grounding the system neutral through impedance
• High resistance ground indication/control panel
The high resistance neutral grounding equipment will contain the following equipment on an operator's panel on the front of the unit as standard:
• Line Disconnect
• Test Push-button
• A digital display unit containing the following functions:
— Green Light to Indicate “Normal” Operating Status
— Flashing red Light to Indicate “Fault” Status
— Red Light to Indicate “Harmonic” Status
— Fault reset
— Alarm silence
— Pulse on/off
— Amber light to indicate “pulse” status
— Indication of Under-Voltage condition
— Indication of Under-Current condition
— Ethernet/Modbus® port for Communications
— Single setpoint Meter Relay
The relay to monitor fundamental voltage and current will incorporate an adjustable time delay function to avoid spurious alarms.
The relay to monitor harmonic voltage and current will incorporate an adjustable time delay function to avoid spurious alarms.

High Resistance Ground Unit for Model 6 MCC


Current Range
System Voltage Configuration Price Space (Inches) Shipping Code
(Ground Current Amps)
480 V, 3-phase, Wye or Delta 1–10 72
$39278. G
600 V, 3-phase, Wye or Delta 2–7 (20 W X 20 D)

Additional Options
Portable hook-on ammeter with carrying case 8800. 0 G

Prices subject to change without notice. PE4 Discount


12/08 Schedule 67
Miscellaneous Units
Automatic Transfer Switches
ASCO 7000 Series Automatic Transfer Switches With Microprocessor Control Panel
The standard automatic transfer switch is the ASCO 7000 Series switch. • Reliable and field proven solenoid operating mechanism
High speed transfer of loads between alternate sources of power, • High withstand and close-on ratings including 30 cycle withstand
regardless of ampacity size, is achieved by a reliable, field proven, current rating for optimum flexibility in circuit breaker coordination
solenoid operating mechanism. When combined with a programmable (600–1200 A)
microprocessor controller with keypad and LCD display, the automatic • Solid, switched, or overlapping neutral conductor options
transfer switch offers the most advanced method of transferring all types • Front replaceable main and arcing contacts (800–1200 A)
of loads, such as, motors, electronic drives, UPS's, and • Programmable microprocessor controller with keypad and LCD
microprocessor-based systems. 7000 Series automatic transfer
display
switches are open transfer in ampacity sizes from 30–1200 A. If you
• Centrally located terminal block for customer control connections
have any questions, contact MCC TAG in Seneca.
(260–1200 A)
• Conventional two-position transfer configuration with automatic • 16mm, industrial grade control switches and indicating lights
control
• Switch position indicators and true source acceptability lights
• UL Listed to 1008 Transfer Switch Equipment and CSA certified to
• Standard ground conductor connections
CSA 22.2 No. 178-1978 Automatic Transfer Switches
• Four auxiliary contacts—two contacts closed when switch is in
• Independently qualified and certified listed to IEC 60947-6-1, CE
normal position and two contacts closed when switch is in emergency
marked (optional). (Limited to certain accessories.)
position
• Rated up to 600 Vac, 30–1200 A

ASCO 7000 Series Pricing


Enter into Quote-To-Cash as a SPECIAL UNIT (see page 1).
Rating Lug Range Price Space (Inches) Shipping Code

3Ø3W – (Can be used with solid neutral through 800 amperes; ASCO accessory 22)
30 A (1) #14–#4/0 $ 39114. 36: MUST be TOP or BOTTOM located
70 A (1) #14–4/0 39836. 36: MUST be TOP or BOTTOM located
100 A (1) #14–4/0 41853. 36: MUST be TOP or BOTTOM located
(2) 1/0–250 kmcil or
150 A 46970. 72 (25 W) q
(1) #4–600 kcmil
G
(2) #1/0–250 kcmil or
260 A 56219. 72 (25 W) q
(1) #4–600 kcmil
(1) #4–600 kcmil or
400 A 61254. 72 (25 W) q
(1) #4–600 kcmil
600 A (3) #2–600 kcmil 87724. 72 (25 W x 20 D) q
800 A (4) 1/0–750 kcmil 107453. 72 (30 W x 20 D) q
Two full sections required H
1200 A (4) 1/0–750 kcmil 150109. 1 @ (30 W x 20 D)
1@ (20 W x 20 D)

3Ø4W With Switched Neutral (Accessory 28)


30 A (1) #14–4/0 43460. 36: MUST be TOP or BOTTOM located
70 A (1) #14–4/0 44887. 36: MUST be TOP or BOTTOM located
100 A (1) #14–4/0 46986. 36: MUST be TOP or BOTTOM located
(2) 1/0–250 kcmil or
150 A 53251. 72 (25 W) q
(1) #4–600 kcmil
G
(2) 1/0–250 kcmil or Contact MCC
260 A 72 (25 W) q
(1) #4–600 kcmil TAG
(2) 1/0–250 kcmil or Contact MCC
400 A 72 (25 W) q
(2) 1/0–250 kcmil TAG
600 A (2) #2–600 kcmil 99745. 72 (25 W x 20 D) q
800 A (4) 1/0–750 kcmil 117900. 72 (30 W x 20 D) q
Two full sections required q H
1200 A (4) 1/0–750 kcmil 177268. 1 @ (30 W x 20 D)
1@ (20 W x 20 D)
q No vertical bus or vertical wireway.

PE4 Discount Prices subject to change without notice.


68 Schedule 12/08
Miscellaneous Units
Automatic Transfer Switches

ASCO 7000 Series Standard Features and Optional Accessories


ASCO
Shipping
Description Accessory Price
Code
Code
Accessory panel required for some ASCO accessories c AP Included
Extended time delay on engine start q 2C 5035.
H
3-phase differential voltage sensing of alternate source q 4E Included
3-phase overvoltage sensing of normal source q 4H Included
Reset switch to manually bypass time delay on retransfer to normal 6B Included
Reset switch to manually retransfer to normal source after time delay 6C 380.
Toggle and selector switches to permit manual or automatic reset to normal 6D 1361.
G
Normal/alternate source available pilot lights. 9C/9D Included
Push-to-test pilot lights for connected-to-normal and
9E/9F 406.
connected-to-emergency source
Engine generator exercise timer with switch to select with load or without load. 11C Included H
Three position engine control switch: Stop/Auto/Engine Test. 12 1361.
Two auxiliary contacts that close when switch is connected to normal source 14A Included
Two auxiliary contacts that close when switch is connected to emergency source 14B Included
G
Two-pole, double throw contacts operate when emergency source voltage is present at transfer switch
18B 1820.
terminals
Two-pole, double throw contacts operate when normal source voltage is present at transfer switch 18G 1820.
terminals
30–150 A switch 541.
260 A switch 787.

Solid neutral for 3-wire switch 400 A switch 1394.


22
(Cannot be used if either source has ground fault protection.) 600 A switch 2197.
800 A switch 2903. H

1200 A switch 4067.


In-phase monitor for motor loads; monitors sources and retransfers to normal when both sources are
27 Included
phase; prevents excess transients on transfer
Equipment ground lug 33 Included
Selective load disconnect control contacts which operate with time delay prior to and/or after load
31Z 1820.
transfer and retransfer
Serial communication module for remote communication 72A 3722. G

Connectivity module for remote communications using Ethernet TCP/IP networks 72E 8528.
c 18 in. additional space required for 30–100 A switches; no additional space required on larger switches.
q Requires accessory panel option AP.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 69
iMCC
Overview and Instructions for Quote-to-Cash
Model 6 iMCC Overview Networking allows for easy monitoring of critical data of each motor or
load connected to the iMCC, enabling precise process control at all
Model 6 iMCCs feature the same overall structure and unit features as
times. With this information, your staff can respond to potential problems
Model 6 Motor Control Centers with additional “intelligent” capabilities.
proactively. Real-time access to information and records of last faults
Schneider Electric supports two popular methods for configuring Model
allows for simplified diagnostics and reduced downtime.
6 iMCCs to customize your application:
Using network control to consolidate all I/O communications significantly
• iMCC-Hardwired I/O: PLC Interwiring
reduces the amount of wiring that would normally be required for a
• iMCC-Network: Network Cabling hardwired I/O MCC with similar functionality. We design a network
iMCC- Hardwired I/O: PLC Interwiring offers a hardwired I/O system in cabling solution that is appropriate for your selected communication
the Model 6 MCC that provides basic information and control network. Our industry-leading full-depth wireway effectively separates
capabilities. With the I/O mounted in the MCC, the starters are wired to network cabling from high voltage cabling. Additionally, our standard
the I/O at the Schneider Electric manufacturing plant and the system is wireway barrier isolates the communication cabling from the load
tested prior to shipment. This pre-wired MCC is more cost effective than cabling routed in the vertical wireway.
separately mounting and wiring the automation hardware outside of the Experience the benefits of an iMCC network:
MCC. This option can also include an independent network.
• Remote monitoring capability
iMCC Network: A key feature of our iMCC-Network solution is the
• Reduced downtime and system interwiring
integration of intelligent devices and device level networks for control
and automation that delivers improved performance. Popular network • Control to every bucket
protocols such as CANopen, DeviceNet™, Ethernet, Modbus®, and • Lower commissioning costs
PROFIBUS communicate directly to every unit of the iMCC for an • Flexible configuration
effective method of connecting centralized control to widely distributed • Cabling system compliant to applicable standards
I/O. The network of your choice creates a common thread for a variety • DeviceNet solution is Open DeviceNet Vendor Association (ODVA)
of motor control equipment that not only improves control, but also certified.
allows for simple and easy installation and operation.

Pricing Instructions
The following procedure details the method for pricing automation in the Quote-To-Cash Entry and Pricing Procedure
Model 6 MCC. This pricing includes space and hardware to mount the Listed below is the method for entering automation components into
equipment, all wiring charges, all automation components, and required Quote-To-Cash.
power supplies. It is no longer necessary to price an empty mounting A. Select iMCC: Hardwired I/O w/ PLC from the Wiring Type drop-down
unit separately when mounting automation components in MCCs. list box on the General Requirements tab.
NOTE: Do not use standard NEMA/EEMAC Class 2 wiring pricing for B. After completing the MCC General Requirements Tab, select
automation interwiring applications. “Programmable Logic Controller” from the device options.
Manual Pricing Procedure: C. Enter a brief description in the designation field of the PLC.
Listed below are the steps used to determine pricing for mounting and D. Select the PLC type/arrangement required from your application,
wiring automation components in an MCC, along with the method for determined from step 1 above. Multiple PLC racks may be selected
determining the delivery code. for Quantum (and Compact®) PLCs. The backplane quantities are
1. Table A on page 72 lists common mounting configurations for added based on your selection. Momentum products do not require
automation components. Contact MCC TAG (Technical Assistance backplanes. Add other PLCs with backplane requirements under
Group) for custom mounting configurations. “additional components” described in Step K.
2. After establishing the appropriate unit size, determine the unit price E. Select the sizing requirements for your application. Note that some
from Table B on page 72; add the price for a foldout PLC rack (if layout space requirements are pre-defined, based on Table A.
desired) from Table C on page 72. F. Select the unit power supply arrangement required for your
3. Use one of these two procedures for selecting factory installed application based on the following options:
automation components in MCCs. 1. 1. 500 VA/120 V adds a 6 in. space with a circuit breaker and
a. For factory supplied Schneider automation components, the 120 Vac power supply.
MCC list price is determined by multiplying the automation list 2. 2.4A/24 Vdc adds a 6 in. space with a circuit breaker and 24 Vdc
price (from bulletin 8000PL9602R3/07) x 6.2, which results in an power supply.
MCC list price (PE4 Discount Schedule). This conversion
3. Add special power supply requirements under “additional
accounts for the conversion of automation to MCC discount
components” described in Step K.
schedules. Note that all Schneider Automation products will be
ordered by the factory for installation into an MCC. Special Notes:
b. For any other automation solution, the pricing levels must be The additional 6 in. space is added directly above the
determined through MCC TAG. To provide automation automation unit. When relay sections are used, power supplies
components (other than Schneider automation) to the factory for do not add additional space. They will be mounted in the relay
installation into an MCC, contact MCC TAG to obtain a “CS” section.
(customer supplied) number. A receiving and handling charge of G. Select the card type power supply arrangement required for your
$2736. per order must be included. application based on the following options:
c. From Table D on page 72, determine pricing for wiring 1. Momentum™ type power supplies are not required.
automation components. 2. Quantum type power supplies: one is required per rack.
d. The shipping code will be the longest code listed for selected 3. Compact 984 power supplies.
units and options from Tables A-D. 4. Add special power supply requirements under “additional
components” described in Step K.

PE4 Discount Prices subject to change without notice.


70 Schedule 12/08
iMCC
Instructions for Quote-to-Cash
H. Select CPU equipment for Momentum, Compact, and Quantum 10. Only Momentum I/O bases require additional communication top
products. All others to be added under “additional components” hats.
described in Step K. L. To add additional devices, repeat Step K as required.
I. Select communication equipment for Momentum, Compact, and
M.If a foldout rack is required, highlight the box. Note that for some
Quantum products. One Momentum top hat is added for each I/O
configurations, the foldout rack is required and selected as default.
base. One Quantum communication card is added for each
backplane. One Compact communication card is added for the unit. All N. Determine the I/O points wired to the units. (select one of the
others to be added under “additional components” described in Step K. following)
J. Typical I/O modules may be selected for Momentum, Compact, and 1. The system will estimate typical I/O requirements based on the
Quantum products. All others to be added under “additional total I/O module I/O count.
components” described in Step K. Note that when the modules are 2. User specified quantity' allows the user to enter the I/O count as
selected, the part numbers are displayed at the bottom of the screen. described in Step O.
3. If interwiring is not required, select 'no interwiring' option. O. Enter
K. Add additional components as required, described in the following
the total quantity of wired I/O points if 'user specified quantity' was
steps:
selected from Step N.
1. Place and “x” in the box beside “I/O and Additional Components.”
P. Determine if interposing terminal blocks are required. (select one of
2. Open Special Features column
the following)
3. Enter the Quantity required
4. Enter the Part Number 1. The system will estimate terminal block requirements based on
5. Enter a brief description of the part the total I/O module I/O count, when you select “Estimate from
6. Enter the list price of the component. Refer to Step 3a to PLC Components.”
determine list price. 2. User specified quantity' allows the user to enter the terminal
7. Select the type of list pricing entered, either a Schneider Electric block count as described in Step Q.
automation list price or MCC list price. 3. If terminal blocks are not required, select “Not Required.” Note
8. Lead time code default is 'G' or 'H'. Contact the Seneca facility for that when the system estimates the terminal blocks, non-fused
expediting. terminal blocks will be used.
9. Identify the number of I/O points associated with this piece of Q.If ‘user specified' quantity was selected from Step P, enter the required
equipment, for example enter '16' for a 16 point input module quantity of non-fused and fused terminal I/O points for your application.
(only required when interposing terminal blocks are used)

Notes
• Applications supporting Size 3 and larger starters require an
interposing relay module that is added when PLC interwiring is
selected in Q2C. Note that some applications require interposing
relays on all motor starters, in this case, the relays must be added
manually in Q2C.
• Standard interwiring terminal blocks use #16 TFFN wire.
• If interposing terminal blocks are specified, wiring to the terminals
from the PLC will be #18 TFFN wire.
• Wire labels on interwiring are included.
• Proper features must be added to each motor starter to ensure that
appropriate I/O points are available, i.e. auxiliary contacts, alarm
contacts.
• For networking and system application capabilities, contact MCC
TAG.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 71
iMCC
Automation Component Mounting and Wiring iMCC-Hardwired I/O with PLC
Table A—Common Mounting Configurations for Automation Components
PLC components are packaged in Schneider Electric MCCs in two mounting information, consult the Model 6 MCC catalog.
distinct configurations; a unit-mount configuration and a full-section NOTE: The configurations shown below represent the maximum PLC
configuration. The unit-mount configuration supports plug-on component densities available. Power distribution, power supplies,
installation and location flexibility in the MCC. The full-section component selection, communication protocol, fusing, interposing
configuration provides increased space for mounting PLCs and relays, and CableFast modules affect the actual component densities.
associated equipment. Two full sections can be joined to provide
maximum mounting space. For additional automation component

Unit Mounts Special Unit (no wireway) a Full Sections


PLC Type 12 in. 18 in. 18 in. 24 in. 20 in. wide 25 in. wide 30 in. wide 35 in. wide
(13.5 in. x 11 in.) (13.5 in. x 17 in.) Height Height (16.4 in. x 63.4 in.) (21.4 in. x 63.4 in.) (26.4 in. x 63.4 in.) (31.4 in. x 63.4 in.)
Momentum™ 2 modules 4 modules 6 modules 8 modules 12 modules 18 modules 24 modules 30 modules
up to 5 up to 5 up to 5 up to 5
1 PLC (fixed I/O) 2 PLC 1 PLC and 1 PLC and
Micro and power supply (fixed I/O) 1 Expansion 2 Expansion interconnected interconnected interconnected interconnected
PLCs PLCs PLCs PLCs
up to one 5-slot rack up to two up to two up to three up to two up to four up to four up to four
Compact
plus one 2-slot rack 5-slot racks 5-slot racks 5-slot racks 5-slot racks 5-slot racks 5-slot racks 5-slot racks
up to one up to one
up to one 6-slot up to four 6-slot up to four 10-slot up to four 10-slot up to four 16-slot
Quantum N/A 10-slot 10-slot
backplane backplanes backplanes backplanes backplanes
backplane backplane
up to two
up to one 8-slot up to one up to four 8-slot up to four 12-slot up to four 12-slot up to four 12-slot
Premium N/A 6-slot
backplane 8-slot backplane backplanes backplanes backplanes backplanes
backplanes
a Special units include 18, 24, 30, and 36 in. high configurations. These units are not plug-in and take up the vertical wireway. They must be mounted at the bottom of a 20
in. wide section.
NOTE: The above table refers to standard configurations. Schneider Electric can also provide custom configurations to meet your specific requirements.
Table B—Unit and Mounting Charges for Automation Table C—PLC Foldout Rack
Components Description Application Price Shipping Code
Unit Height 6 in. foldout rack 12 in. unit or larger $410.
Price Shipping Code
Inches mm
12 in. foldout rack 18 in. unit or larger 410. H
6.00 152 $ 4006.
9.00 229 4178. 18 in. foldout rack 24 in. unit or larger 410.
12.00 305 4312.
15.00 381 4472. Table D—Wiring Charges for Automation Components in
18.00 457 4584. MCCs
21.00 533 4732.
24.00 610 4856. Description of Space Shipping
Charge Application Price (inches) Code
27.00 686 5004.
30.00 762 5162. I/O wiring
33.00 838 5298. PLC space $160./point 0
charge
36.00 914 5434.
39.00 991 5298. H Interposing PLC space 90./point 0 H
42.00 1067 5716. terminals
48.00 1219 6010. Fused
60.00 1524 6586. PLC space 190./point 0
terminals
72.00 (20 W) 1829 8306.
72.00 (25 W) 1829 11080. Options for Automation Components in MCCs
72.00 (30 W) 1829 12450.
72.00 (35 W) 1829 15050. Space Shipping
Description of Charge Application Price
18.00a 457 5626. (inches) Code
24.00a 610 6226. 24 Vdc Control power
30.00a 762 6882. supply rated 8 A
36.00a 914 7506. — $7236. 6 E
a20 in. wide compartment (refer to special unit in Table A above)0 Power supply unit 500 VA/
115 Vac
120 Vac starter interposing Size 3–5
relay starters
328.
24 Vdc starter interposing

relay 0 E
Telemecanique relay Size 3–5
528.c
module starters
Surge suppressor All starters 102.c
c Required, included in standard pricing.

PE4 Discount Prices subject to change without notice.


72 Schedule 12/08
iMCC
iMCC-Network Cabling
iMCC-Network Cabling Ethernet Switches
There are two primary ways to have your Ethernet communications
Class 1 cabling is 600 V, 8 A rated, 15 AWG power pair, 18 AWG data
network configured: distributed switch(es) per shipping split or
pair with a braided shield and drain. This cable solution provides current
centralized switch(es) per MCC.
protection, eliminating the need for a vertical wireway communication
barrier. (The communication barrier option is still available.) • 48 ports maximum per unit
• Schneider Electric recommends utilizing only 80% of ports for I/O,
Class 2/CM cabling is 600 V, 22 AWG, 4-conductor with a foil shield and
interconnectivity expansion, etc.
drain.
• 8-port switch unit can be mounted anywhere
Class 2/CM and CAT5E rated cable solutions require a mechanical • Switch units with more than 8 ports must be bottom located
barrier for standard sections. • Switch units require a separate 6 in. unit, 8 A power supply

iMCC-Network Cabling Pricing Ethernet Switch Pricing


Price per Shipping Price Shipping
Network Description Port Count Space
Section Code Code
Unmanaged Managed
Class 1, 600 V, 8 A rated.
15 AWG (power pair), 8 $2800. — 12
CANopen c $3200.
18 AWG (data pair), 16 6600. $ 8500. E
braided Shield w/ drain 18
24 8400. 15000.
Class 1, 600 V, 8 A rated. D
Open DeviceNet Vendor
Association (ODVA)
DeviceNet™ c 3200. Ethernet Switch Option Pricing
approved 15 AWG (power
pair), 18 AWG (data pair),
braided Shield w/ drain Shipping
Option Price Space
Code
CAT5E cables connect
Ethernet devices to centralized 1800. E 24 Vdc power supply rated 8 A $7236. 6 E
switch a
Class 2/CM Cabling, 600 V
Modbus® 22 AWG, 4 conductor w/ 2048. D
foil shield and drain
Class 2/CM Cabling, 600 V
PROFIBUS 22 AWG, 4 conductor w/ 2048. E
foil shield and drain
c Optional Class 2/CM cabling available for DeviceNet and CANopen
applications. Consult the MCC TAG for pricing and Quote-To-Cash selector
assistance.
a See the “Ethernet Switch Pricing” table at right.

iMCC-Network Option Pricing


Price per Shipping
Option Description
Section Code
Mounted in vertical
Communication Barrier q wireway.
Adds additional
mechanical protection for $320. E
network cable.
q Optional for Class 1 cabling only. Communication barrier mounted in vertical
wireway of Standard Section supplied as standard with Ethernet, Modbus, and
PROFIBUS Class2/CM applications.

Prices subject to change without notice. PE4 Discount


12/08 Schedule 73
iMCC
Gateways
Repeaters/Bridges/Gateways
Repeaters, bridges and gateways are recommended for the following • Use two repeaters when the iMCC is located in middle of a network.
applications/reasons: • Ground levels can vary from enclosure to enclosure, thus the
• Provide a convenient termination point for network cabling. possibility exists of introducing noise into a system if a repeater is not
• Allow the iMCC to be isolated and tested as a subsystem for ease of implemented.
troubleshooting. • Repeaters are typically not required for short cable runs routed in the
same area.
Model 6 iMCC Bridges/Repeaters
Space MCC
Shipping
Network Description Adder List Price Adder Notes
Code
(in.) q
Manufactured by
RS-485 repeater 9 5140.
B&B Electronics
Modbus®
PowerLogic® RS-232/RS-485 converter 9 9504.

24 Vdc/8 A Power Supply 6 7236.


Default with iMCC-Network
with PROFIBUS
PROFIBUS Cable Terminations 9 1500.
PROFIBUS Cable Terminations 9 5140.
PROFIBUS with RS-485 Repeater H
PROFIBUS Cable Terminations 9 2868.
with PROFIBUS Active Terminations Manufactured by Siemens
PROFIBUS Cable Terminations
with RS-485 Repeater and 9 7270.
PROFIBUS Active Terminator
24 Vdc/8 A Power Supply 6 7236.
DeviceNet™
Repeater 9 7148.

q List Price Adder. This table includes the Unit Mounting Charge from Table B on page 72.

PE4 Discount Prices subject to change without notice.


74 Schedule 12/08
Index

Subject . . . . . . . . . . . . . . . . . . . . . . . . . . Page Subject . . . . . . . . . . . . . . . . . . . . . . . . . . Page


2 in. Horizontal Bus . . . . . . . . . . . . . . . . . . . . 4 Copper Crimp Lugs . . . . . . . . . . . . . . . . . . . 60
2-Speed Starters . . . . . . . . . . . . . . . . . . 26, 33 Copper Vertical Ground. . . . . . . . . . . . . . . . . 4
3-Point Door Latch. . . . . . . . . . . . . . . . . . . . 64 Corner Sections . . . . . . . . . . . . . . . . . . . . . . . 5
4-wire Systems . . . . . . . . . . . . . . . . . . . . . . 13 Cover Plate . . . . . . . . . . . . . . . . . . . . . . . . . 64
Crimp Lugs—Copper. . . . . . . . . . . . . . . . . . 60
AccuSine® Power Correction System . . . . . 61 Current Limiting Module . . . . . . . . . . . . . . . 59
Additional Overload Relay. . . . . . . . . . . . . . 50 Current Transformer . . . . . . . . . . . . . . . . . . 16
Adjustable Frequency Controller. . . . . . . . . 48 Customer Device Mounting Units . . . . . . . . 64
Alarm Contact—C/B . . . . . . . . . . . . . . . . . . 50
Alarm Contact—O/L . . . . . . . . . . . . . . . . . . 50 Deceleration Relay . . . . . . . . . . . . . . . . . . . 46
Alternator . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Aluminum Bus . . . . . . . . . . . . . . . . . . . . . . . . 4 Depth of Enclosures . . . . . . . . . . . . . . . . . . . 4
Altistart® Soft Start . . . . . . . . . . . . . . . . . . . . 43 Distribution Panelboards . . . . . . . . . . . . . . . 63
Altivar® Drives. . . . . . . . . . . . . . . . . . . . . . . . 35 Distribution Transformers . . . . . . . . . . . . . . 62
Ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Documentation. . . . . . . . . . . . . . . . . . . . . . . . 3
Application-Rated Devices . . . 22, 23, 30, 31 Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Autotransformer Thermal Sensor . . . . . . . . 24 Drip Hood. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Automatic Bus Shutters. . . . . . . . . . . . . . . . . 5 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Automatic Transfer Switch . . . . . . . . . . . . . 68 Duplex Alternator . . . . . . . . . . . . . . . . . . . . . 46
Auxiliary Contacts—C/B Internal. . . . . . . . . 50 Dust Boots For Pilot Devices. . . . . . . . . . . . 48
Auxiliary Contacts . . . . . . . . . . . . . . . . . . . . 50
Auxiliary Interlocks. . . . . . . . . . . . . . . . . . . . 50 Elapsed Time Meter . . . . . . . . . . . . . . . . . . 16
Electrical Interlocks . . . . . . . . . . . . . . . . . . . 50
Back-to-back Construction . . . . . . . . . . . . . . 5 Electronic Breaker W/GFI . . . . . . . . . . . . . . 13
Barriers-fishtape. . . . . . . . . . . . . . . . . . . . . . . 5 Electronic Breaker W/O GFI . . . . . . . . . . . . 13
Barriers-rodent. . . . . . . . . . . . . . . . . . . . . . . . 5 Empty Mounting Unit . . . . . . . . . . . . . . . . . . 64
Barriers-vertical Wireway. . . . . . . . . . . . . . . . 5 Empty Space . . . . . . . . . . . . . . . . . . . . . . . . 64
C/B FVPW Starters . . . . . . . . . . . . . . . . . . . 25 Enclosure Type . . . . . . . . . . . . . . . . . . . . . . . 4
Bimetal Overload . . . . . . . . . . . . . . . . . . . . . 50 Engraved Nameplates. . . . . . . . . . . . . . . . . 47
Blank Cover Plates . . . . . . . . . . . . . . . . . . . 64 Equipped Space . . . . . . . . . . . . . . . . . . . . . 64
Bottom Plate—NEMA/EEMAC Type 1. . . . . 5 Extended Warranty . . . . . . . . . . . . . . . . . . . . 3
Bus Bar Surge Protection . . . . . . . . . . . . . . . 4 Extra High Interrupting C/B . . . . . . . . . . . . . 58
Bus Barrier Closing Plugs . . . . . . . . . . . . . . . 5
Bus Duct Connection. . . . . . . . . . . . . . . . . . . 6 F/S FVNR Starters. . . . . . . . . . . . . . . . . . . . 21
Bus Material/amperage . . . . . . . . . . . . . . . . . 4 F/S FVR Starters . . . . . . . . . . . . . . . . . . . . . 30
Bus Withstand Rating . . . . . . . . . . . . . . . . . . 4 F/S 2-Speed Starters. . . . . . . . . . . . . . . . . . 33
Bypass/Isolation Contactors . . . . . . . . . . . . 53 F/S Branch Feeder . . . . . . . . . . . . . . . . . . . 20
F/S FVPW Starters . . . . . . . . . . . . . . . . . . . 25
C/B FVNR Starters . . . . . . . . . . . . . . . . . . . 21 Filler Plates . . . . . . . . . . . . . . . . . . . . . . . . . 64
C/B FVR Starters. . . . . . . . . . . . . . . . . . . . . 23 Fishtape Barriers . . . . . . . . . . . . . . . . . . . . . . 5
C/B RVAT Starters . . . . . . . . . . . . . . . . . . . 24 Four-wire Systems. . . . . . . . . . . . . . . . . . . . 13
C/B 2-Speed Starters . . . . . . . . . . . . . . . . . 26 Fuses—Metering . . . . . . . . . . . . . . . . . . . . 16
C/B Branch Feeder . . . . . . . . . . . . . . . . . . . 19 Fuseclips . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Cam Operated Switch . . . . . . . . . . . . . . . . . 48 Fuses—Control Circuit . . . . . . . . . . . . . . . . 47
Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Fuses—Power Circuit . . . . . . . . . . . . . . . . . 57
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . 5 Fusible Switch Branch Feeders . . . . . . . . . 20
Circuit Breaker Options . . . . . . . . . . . . . . . . 58 Fusible Switch Mains. . . . . . . . . . . . . . . . . . 12
Circuit Breakers—Branch Feeder. . . . . . . . 19 Fusible Switch Options . . . . . . . . . . . . . . . . 57
Circuit Breakers—Main . . . . . . . . . . . . . . . . . 8 Future Space . . . . . . . . . . . . . . . . . . . . . . . . 64
Circuit Breakers—Panelboard . . . . . . . . . . 63
Class 2 Wirings . . . . . . . . . . . . . . . . . . . . . . 60 GFI . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 13, 63
Class R/J Fuse Clips . . . . . . . . . . . . . . . . . . 57 Ground Detection Lights . . . . . . . . . . . . . . . 16
CLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Ground Fault Protection . . . . . . . . . . . . . . . 59
Closing Plugs—Vertical Bus . . . . . . . . . . . 4, 5
Compac™ 6 . . . . . . . . . . . . .22-23, 30-31, 72 iMCCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Compelling Relay. . . . . . . . . . . . . . . . . . . . . 46 Incoming Main . . . . . . . . . . . . . . . . . . . . . . . 13
Control Circuit Variations. . . . . . . . . . . . . . . 47 Inspections. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Control Relay . . . . . . . . . . . . . . . . . . . . . . . . 46 Interlock—C/B Internal . . . . . . . . . . . . . . . . 58
Control Station Plate . . . . . . . . . . . . . . . 48, 49 Isolated O/L Alarm Contacts . . . . . . . . . . . . 50
Control Terminal Blocks . . . . . . . . . . . . . . . 60
Control Wire . . . . . . . . . . . . . . . . . . . . . . . . . 60 Key Interlock . . . . . . . . . . . . . . . . . . . . . 57, 58
Copper Bus . . . . . . . . . . . . . . . . . . . . . . . 6, 63

Prices subject to change without notice. PE4 Discount


12/08 Schedule 75
Index

Subject . . . . . . . . . . . . . . . . . . . . . . . . . . Page Subject . . . . . . . . . . . . . . . . . . . . . . . . . . Page


Latching Relay . . . . . . . . . . . . . . . . . . . . . . . 46 Selector Switches . . . . . . . . . . . . . . . . . . . . 48
Lightning Arrestor . . . . . . . . . . . . . . . . . . . . . 4 Separate Control . . . . . . . . . . . . . . . . . . . . . 47
Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Service Entrance . . . . . . . . . . . . . . . . . . . . . 13
Line Voltage Control . . . . . . . . . . . . . . . . . . 47 Shunt Trip. . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Lug Compartments . . . . . . . . . . . . . . . . . . . . 7 Silver-plated Bus . . . . . . . . . . . . . . . . . . . . . . 4
Smaller Fuseclips . . . . . . . . . . . . . . . . . . . . 57
Main Bus Material/amperage . . . . . . . . . . . . 4 Solid Neutral. . . . . . . . . . . . . . . . . . . . . . . . . 13
Main Circuit Breaker . . . . . . . . . . . . . . . . . . . 8 Solid State Overloads . . . . . . . . . . . . . . . . . 52
Main Fusible Switch. . . . . . . . . . . . . . . . . . . 12 Special Packaging . . . . . . . . . . . . . . . . . . . . . 3
Main Lug Compartments. . . . . . . . . . . . . . . . 7 Special Paint . . . . . . . . . . . . . . . . . . . . . . . . . 5
Master Nameplate . . . . . . . . . . . . . . . . . . . . 47 Starter Interlocks . . . . . . . . . . . . . . . . . . . . . 50
Master Terminal Compartments . . . . . . . . . 64 Strip Heater . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Metering Options . . . . . . . . . . . . . . . . . . . . . 16 Structure Pricing . . . . . . . . . . . . . . . . . . . . . . 4
Micrologic® Electronic Trip Unit Options . . . 59 Surge Protection . . . . . . . . . . . . . . . . . . . . . . 4
Model 4 Or Model 5 Transition Section . . . . 6 Surge Suppressor—Starter Coil . . . . . . . . . 47
Motor Operated Timer . . . . . . . . . . . . . . . . . 46 Switchboard Transition Section. . . . . . . . . . . 6
Motor Winding Heater . . . . . . . . . . . . . . . . . 46
Motor Logic® . . . . . . . . . . . . . . . . . . . . . . . . . 52 TVSS Units . . . . . . . . . . . . . . . . . . . . . . . . . 17
Motor Logic Plus™ . . . . . . . . . . . . . . . . . . . 52 Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . 60
Terminal Compartments . . . . . . . . . . . . . . . 64
Nameplates . . . . . . . . . . . . . . . . . . . . . . . . . 47 Terminals—Ring Tongue . . . . . . . . . . . . . . 60
NEMA/EEMAC Class 2 Wiring . . . . . . . . . . 60 Terms And Conditions. . . . . . . . . . . . . . . . . . 3
NEMA/EEMAC Enclosure Type . . . . . . . . . . 4 TeSys® T Motor Management Controller . . 51
NEMA/EEMAC Type C Wiring . . . . . . . . . . 60 Thermal Units. . . . . . . . . . . . . . . . . . . . . . . . 50
Neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Thermostat For Strip Heater . . . . . . . . . . . . . 5
Through The Back Splice . . . . . . . . . . . . . . . 5
Omit Control Station Plate. . . . . . . . . . . . . . 48 Time Meter. . . . . . . . . . . . . . . . . . . . . . . . . . 15
Omit Horizontal Bus. . . . . . . . . . . . . . . . . . . 64 Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Omit Overload Relay . . . . . . . . . . . . . . . . . . 50 Tin-plated Bus . . . . . . . . . . . . . . . . . . . . . . . . 4
Order Entry Instructions. . . . . . . . . . . . . . . . . 1 Top Hat (Pull Box) . . . . . . . . . . . . . . . . . . . . . 5
Outdoor Enclosures. . . . . . . . . . . . . . . . . . . . 4 Top Plate—Two Piece. . . . . . . . . . . . . . . . . . 5
Overload Alarm Light. . . . . . . . . . . . . . . . . . 50 Transient Suppression Mod . . . . . . . . . . . . 47
Overload Relay Options . . . . . . . . . . . . . . . 50 Transformer—Control Circuit . . . . . . . . . . . 47
Overvoltage Relay . . . . . . . . . . . . . . . . . . . . 46 Transformer—Current . . . . . . . . . . . . . . . . . 16
Transformer—Distribution . . . . . . . . . . . . . . 62
Paint—Special Colors . . . . . . . . . . . . . . . . . . 5 Transformer—Potential . . . . . . . . . . . . . . . . 16
Panelboards. . . . . . . . . . . . . . . . . . . . . . . . . 63 Transient Surge Suppressor . . . . . . . . . . . . 17
Phase Failure/Loss/Reversal Relay . . . . . . 46 Transition To Model 4 . . . . . . . . . . . . . . . . . . 6
Pilot Devices . . . . . . . . . . . . . . . . . . . . . . . . 48 Transparent Ready® . . . . . . . . . . . . . . . . . . 66
Pilot Lights . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Two Speed Starters. . . . . . . . . . . . . . . . 26, 33
Pneumatic Timer . . . . . . . . . . . . . . . . . . . . . 46 Two Speed Reversing Starters . . . . . . . 26, 33
Potential Transformers . . . . . . . . . . . . . . . . 16 Type C Wiring . . . . . . . . . . . . . . . . . . . . . . . 60
Power Factor Correction Capacitors. . . . . . 65 Type K Pilot Devices . . . . . . . . . . . . . . . . . . 48
PowerLogic® Monitoring . . . . . . . . . . . . . . . 14
Power Meter. . . . . . . . . . . . . . . . . . . . . . . . . 15 Undervoltage Relay . . . . . . . . . . . . . . . . . . . 46
Power Terminal Blocks . . . . . . . . . . . . . . . . 60 Undervoltage Trip . . . . . . . . . . . . . . . . . . . . 58
Pricing Instructions . . . . . . . . . . . . . . . . . . . . 1 Unit Extenders . . . . . . . . . . . . . . . . . . . . . . . 57
Pull Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Unit Nameplates . . . . . . . . . . . . . . . . . . . . . 47
Push Button . . . . . . . . . . . . . . . . . . . . . . . . . 48 Unit Only Pricing . . . . . . . . . . . . . . . . . . . . . . 1
Push-to-Test Pilot Lights . . . . . . . . . . . . . . . 49 Unwired Terminal Compartment. . . . . . . . . 64

QO-QOB Circuit Breakers. . . . . . . . . . . . . . 63 Vertical Bus—600 A . . . . . . . . . . . . . . . . . . . 4


Vertical Wireway—9 in. Wide . . . . . . . . . . . . 5
Relay Adder Deck . . . . . . . . . . . . . . . . . . . . 46 Vertical Wireway—Barriers . . . . . . . . . . . . . . 5
Relay Latch Attachment . . . . . . . . . . . . . . . 46 Vertical Wireway—Tie Retainers . . . . . . . . . 5
Relay Sections. . . . . . . . . . . . . . . . . . . . . . . 64
Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Reset Button—Omit. . . . . . . . . . . . . . . . . . . 50 Wire—Control . . . . . . . . . . . . . . . . . . . . . . . 60
Reversing Starters. . . . . . . . . . . . . . . . . 23, 30 Wire Labels . . . . . . . . . . . . . . . . . . . . . . . . . 60
Ring Tongue Terminals. . . . . . . . . . . . . . . . 60 Wire Tie Retainers. . . . . . . . . . . . . . . . . . . . . 5
Rodent Barriers . . . . . . . . . . . . . . . . . . . . . . . 5 Wiring—Class 2. . . . . . . . . . . . . . . . . . . . . . 60
Running Time Meter . . . . . . . . . . . . . . . . . . 15 Wiring—Type C . . . . . . . . . . . . . . . . . . . . . . 60
Witness Testing . . . . . . . . . . . . . . . . . . . . . . . 3
Wye-Delta Starters . . . . . . . . . . . . . 27-28, 34

PE4 Discount Prices subject to change without notice.


76 Schedule 12/08
Schneider Electric USA
1990 Sandifer Blvd.
Seneca, SC 29678 USA
1-888-Square D
1-888-778-2733 8998PL9202R12/08 © 1996–2008 Schneider Electric All Rights Reserved
www.schneider-electric.us Replaces 8998PL9202R8/07 08/2007

12/2008