Differential pressure flow meters
ISO 5167 – 1 : This part of ISO 5167 defines
2003 terms and symbols and establishes
Measurement of the general principles for methods
fluid flow by means of measurement and computation
of pressure of the flow rate of fluid flowing in a
differential devices
inserted in circular conduit by means of pressure
cross section differential devices (orifice, nozzle&
running full – Part venturi) when they are inserted in
1. a circular cross section conduit
General principles running full. This part also
and specifies the general requirements
requirements for methods of measurement,
installation and determination of
uncertainty of the measurement of
flow rate.
Differential pressure flow meters
ISO 5167 – 2 : 2003 This part of ISO 5167 specifies
Measurement of fluid the geometry and method of use
flow by means of (installation and operating
pressure differential conditions) of orifice plates
devices inserted in
circular cross section when they are inserted in a
running full – Part 2. conduit running full to
Orifice plates determine the flow rate of the
fluid flowing in the conduit.
This part also provides
background information for
calculating the flow rate and is
applicable in conjunction with
the requirements given in ISO
5167 - 1
Differential pressure flow meters
ISO 5167 – 2 : 2003 This part of ISO 5167 is
Measurement of fluid applicable only to a flow which
flow by means of remains subsonic throughout
pressure differential the measuring section and were
devices inserted in
circular cross section the fluid can be considered as
running full – Part 2. single phase. It is not applicable
Orifice plates to the measurement of
pulsating flow. It does not cover
the use of orifice plates in pipe
sizes less than 50 mm or more
than 1000 mm or pipe Reynolds
number below 5000.
Differential pressure flow meters
ISO 5167 – 3 : 2003 This part of ISO 5167 specifies
Measurement of fluid the geometry and method of use
flow by means of (installation and operating
pressure differential conditions) of nozzles and
devices inserted in
circular cross section venturi nozzles when they are
running full – Part 3. inserted in a conduit running
Nozzles and Venturi full to determine the flow rate of
nozzles the fluid flowing in the conduit.
This part also provides
background information for
calculating the flow rate and is
applicable in conjunction with
requirements given in ISO
5167-1.
Differential pressure flow meters
ISO 5167 – 3 : 2003 This part of ISO 5167 is
Measurement of fluid applicable only to a flow which
flow by means of remains subsonic throughout
pressure differential the measuring section and were
devices inserted in
circular cross section the fluid can be considered as
running full – Part 3. single phase. It is not applicable
Nozzles and Venturi to the measurement of
nozzles pulsating flow. It does not cover
the use of nozzles and venturi
nozzles in pipe sizes less than
50 mm or more than 630 mm
or pipe Reynolds number below
10000.
Differential pressure flow meters
ISO 5167 – 3 : 2003 This part of ISO 5167 deals
Measurement of fluid with
flow by means of
1. Standard nozzles
pressure differential
devices inserted in a) ISA nozzle
circular cross section 1932 nozzle
running full – Part 3.
b) Long radius nozzle
Nozzles and Venturi
nozzles 2. Venturi nozzles