Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
Abstract
Contents
1 REVISION INFORMATION........................................................................................ 1
2 DESCRIPTION........................................................................................................... 1
3 DATA TRANSCRIPT IMPACTS................................................................................. 2
3.1 GENERAL ............................................................................................................... 2
3.2 SUBFILE 10000 - APT SIZE ALTERATION EVENTS............................................ 2
3.3 SUBFILE 87XXX - DEFINITION OF TG, SITE XXX................................................ 2
3.4 SUBFILE 94XXX - DEBLOCKING OF DIP (& TRI) AND DCP/TRI
SEMIPERMANENT PATHS, SITE XXX......................................................... 2
4 MISCELLANEOUS INFORMATION........................................................................... 3
5 REFERENCES........................................................................................................... 3
1 REVISION INFORMATION
2 DESCRIPTION
The feature detects faults in the transmission interface (DXU) for RBS 2000
and separates faults in the RBS 2000 from faults in the transmission network.
If a transmission module is used, this feature will detect faults in the
transmission interface between the DXU and the transmission module.
DESCRIPTION 2 (3)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
3.1 GENERAL
Control parameters for PCM fault management and PCM quality supervision
can be set by command.
The feature supervises the PCM link using the DIP (Digital Path) defined for
the MO (Managed Object).
RXMOI:MO=RXODP-0-0, DEV=RXODPI-0;
RXMOI:MO=RXODP-0-1, DEV=RXODPI-1; !IF 2:ND DIP IS USED!
The DIP definition must be standardised to improve the work process with
that purpose we have the next format:
DIP=xODPyyy.
DTDII:DIP=1ODP0, DEV=RXODPI-1;
DTIDC:DIP=1ODP0, CRC=0;
DTFSC:DIP=1ODP0, FAULT=1&&4&9, ACL=A2;
DTFSI:DIP=1ODP0, FAULT=1&&4&9;
DTQSC:DIP=1ODP0, BFF, BFFL1=100, ACL1=O1, BFFL2=800, ACL2=O1;
DTQSC:DIP=1ODP0, SF, SFL=5, ACL=O1, TI=24;
DTQSC:DIP=1ODP0, DF, DFL=100, ACL=O1, TI=24;
DTQSI:DIP=1ODP0, BFF, LH, LL, SF, DF;
4 MISCELLANEOUS INFORMATION
There are two different types of digital paths: 1544 kbits/s and 2048 kbits/s.
To obtain more information about options see application information for
block RXODPI.
5 REFERENCES