BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

WORK BELOW LOWEST FLOOR FINISH

EXCAVATION AND EARTHWORK

EXCAVATION

Excavating to reduce level; to formation level; commencing


from ground level

A Maximum depth not exceeding 0.25m 123.00 M3

Excavating pit starting from reduced level; including


backfilling with approved excavated material, compaction in
layers and disposal of surplus excavated material where
directed within the site

To receive pile caps

B Maximum depth not exceeding 2.00m 107.00 M3

Excavating trenches starting from reduced level; including


backfill with approved excavated material, compaction in
layers and disposal of surplus excavated material where
directed within the site

To receive ground beams

C Maximum depth not exceeding 1.00m 61.00 M3

FILLING

Hardcore as specified

D To make up levels not exceeding 250mm thick; average 491.00 M2


250mm thick

CONCRETE WORK

IN-SITU CONCRETE

Plain Concrete Grade 15 as specified; blinding screed; laid on


earth or hardcore

Under pile caps

E Not exceeding 100mm thick 4.00 M3

Under ground beam

F Not exceeding 100mm thick 6.00 M3

Under ground floors slab

G Not exceeding 100mm thick 25.00 M3

1 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:WORK BELOW LOWEST FLOOR FINISH (Contd)

:CONCRETE WORK (Contd)

Reinforced Concrete Grade 25 as specified

Reinforced concrete stage including all necessary


reinforcement and formwork with 900mm wide step both side,
finished with 300mm x 300mm x 7.5mm thick dark colour
ceramic tile laid to pattern; with mild steel grille fixed to both
sides of wall (wall measured separately) all as per drawing
No. JKR(CB)32(LR)900/01/DB/13A

A 7685mm x 4300mm x 450mm High (Overall) 1.00 NO

Reinforced Concrete Grade 30 as specified

Foundations or the likes;

B In pile caps (44 nos) 64.00 M3

C In column stumps (Provisional) 4.00 M3

Ground Beams or the likes;

D In ground beams 58.00 M3

Bed and Ground Floor Slab or the likes;

In ground floor slab

E 100mm - 150mm Thick 74.00 M3

Reinforcement bars; hot rolled plain round mild steel

Foundations or the likes;

In pile caps

F 10mm Diameter; links or the likes 65.00 KG

G 12mm Diameter; links or the likes 1144.00 KG

In column stumps (Provisional)

H 10mm Diameter; links or the likes 145.00 KG

Ground beams or the likes;

In ground beams

J 10mm Diameter; links or the likes 3742.00 KG

2 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:WORK BELOW LOWEST FLOOR FINISH (Contd)

:CONCRETE WORK (Contd)

Reinforcement bars; hot rolled deformed high tensile steel

Foundations or the likes;

In pile caps

A 16mm Diameter; straight and bent 2295.00 KG

B 20mm Diameter; straight and bent 1389.00 KG

C 25mm Diameter; straight and bent 2166.00 KG

In column stumps (Provisional)

D 20mm Diameter; straight and bent 2984.00 KG

Ground beams or the likes;

In ground beams

E 12mm Diameter; straight and bent 12.00 KG

F 16mm Diameter; straight and bent 1868.00 KG

G 25mm Diameter; straight and bent 6873.00 KG

Ground floor slab or the likes;

In ground floor slab

H 10mm Diameter; straight and bent 595.00 KG

Reinforcement; fabric; hard drawn plain round steel, welded


as described

Slab or the likes

J In ground floor slab; Reference B385 767.00 M2

Class F1 formwork as specified

Foundations or the likes

To edges and faces pile caps

K 500mm - 1.00m High 223.00 M

L To sides of column stumps (Provisional) 40.00 M2

Ground beams or the likes

To edges and faces ground beams

M 250mm - 500mm High 755.00 M

3 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:WORK BELOW LOWEST FLOOR FINISH (Contd)

:WATERPROOFING AND ASPHALT WORK (Contd)

WATERPROOFING AND ASPHALT WORK

DAMP PROOFING AND TANKING

Damp Proof Membrane as specified

Coverings; 1 layer of Polyurethane Bitumen (anti-hydro) sheet


as specified, 1.25mm thick; laid on hardcore

A Over 300mm wide; flat; subsequently covered 491.00 M2

ELECTRICAL INSTALLATIONS

BUILDERS WORK

Builders work in connection with Electrical Installations in


new structures

Cable trench/pit

B 500mm x 600mm Deep trench hole constructed of 100mm 13.00 M


thick wall and concrete floor slab Grade 25 with 50mm thick
removable concrete cover slab and fill in with sand all as per
drawing no. JKR(CB)32(SP)900/02/DB(1)/14

C 950mm x 650mm x 625mm Deep cable pit constructed of 1.00 NO


100mm thick wall and concrete floor slab Grade 25 including
cover slab all as per drawing no.
JKR(CB)32(SP)900/02/DB(1)/14

D 400mm x 300mm Deep (internal size) pit with 100mm x 2.00 NO


100mm kerb with removable precast concrete cover all as per
drawing no. JKR(CB)32(SP)900/02/DB(1)/14

E 600mm x 300mm Deep (internal size) pit with 100mm x 2.00 NO


100mm kerb with removable precast concrete cover all as per
drawing no. JKR(CB)32(SP)900/02/DB(1)/14

F Supply and install 3 nos. 150mm diameter fibre glass wool 1.00 NO
pipe in 6000mm length each including all necessary
excavation; etc and all as per drawing no.
JKR(CB)32(SP)900/02/DB(1)/14

4 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:WORK BELOW LOWEST FLOOR FINISH (Contd)

:ELECTRICAL INSTALLATIONS (Contd)

A Supply and install 3nos. 150mm diameter uPVC pipe 3.00 M


including all necessary excavation; etc and all as per drawing
no. JKR(CB)32(SP)900/02/DB(1)/14

5 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:WORK BELOW LOWEST FLOOR FINISH

B03/1

B03/2

B03/3

B03/4

B03/5

6 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

RAMPS, APRON AND PERIMETER DRAINS

EXCAVATION AND EARTHWORK

FILLING

Hardcore as specified

A To make up levels not exceeding 250mm thick; average 293.00 M2


150mm thick

CONCRETE WORK

IN-SITU CONCRETE

Plain Concrete Grade 7 as specified; blinding screed; laid on


earth or hardcore

Under apron slab

B Not exceeding 100mm thick 15.00 M3

Reinforced Concrete Grade 30 as specified

Bed and Ground Floor Slab or the likes;

In apron slab

C Not exceeding 100mm thick; laid to slope not exceeding 15 29.00 M3


degree

In ramp

D 1200mm x 350mm x 70mm (Average) thick ramp; reinforced 2.00 NO


with BRC A7 including all necessary formwork and cement
and sand (1:3) screed in cheveron shape

Reinforcement bars; hot rolled deformed high tensile steel

Ground floor slab or the likes;

In apron slab

E 10mm Diameter; straight and bent 935.00 KG

Reinforcement; fabric; hard drawn plain round steel, welded


as described

Slab or the likes

F In apron slab; Reference B385 493.00 M2

Class F1 formwork as specified

Ground floor slab or the likes

To edges and faces of apron slabs

G Not exceeding 250mm high 32.00 M

7 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:RAMPS, APRON AND PERIMETER DRAINS (Contd)

:DRAINAGE (Contd)

DRAINAGE

DRAINS

Surface Water Channels

Precast concrete Grade 20 surface water drain pipe and


fittings as specified; laid and jointed in trench, on and
including 450mm x 75mm thick concrete as specified bed;
including all necessary excavation, backfilling, formwork and
remove surplus excavated material

A 230mm Diameter half round drain; not exceeding 2.0m deep, 147.00 M
average 0.25m deep

B 230mm Diameter drain; not exceeding 2.0m deep, average 15.00 M


0.25m deep; laid under concrete slab

8 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:RAMPS, APRON AND PERIMETER DRAINS

B03/7

B03/8

9 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

FRAME

CONCRETE WORK

IN-SITU CONCRETE

Reinforced Concrete Grade 30 as specified

Columns or the likes;

A In columns 62.00 M3

Beams or the likes;

B In floor beams 91.00 M3

C In roof beams 27.00 M3

Reinforcement bars; hot rolled plain round mild steel

Columns or the likes;

In columns

D 6mm Diameter; links or the likes 6.00 KG

E 10mm Diameter; links or the likes 2309.00 KG

Beams or the likes;

In floor beams

F 10mm Diameter; links or the likes 6238.00 KG

In roof beams

G 10mm Diameter; links or the likes 1239.00 KG

Reinforcement bars; hot rolled deformed high tensile steel

Columns or the likes;

In columns

H 12mm Diameter; straight and bent 210.00 KG

J 16mm Diameter; straight and bent 3769.00 KG

K 20mm Diameter; straight and bent 9548.00 KG

Beams or the likes;

In floor beams

L 12mm Diameter; straight and bent 190.00 KG

M 16mm Diameter; straight and bent 2653.00 KG

N 25mm Diameter; straight and bent 13248.00 KG

In roof beams

P 16mm Diameter; straight and bent 2662.00 KG

10 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:FRAME (Contd)

:CONCRETE WORK (Contd)

Class F1 formwork as specified

Columns or the likes

A To sides of columns 722.00 M2

Beams or the likes

To sides and soffits of floor beams

B Horizontal 936.00 M2

To sides and soffits of roof beams

C Horizontal 378.00 M2

11 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:FRAME

B03/10

B03/11

12 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

UPPER FLOOR

CONCRETE WORK

IN-SITU CONCRETE

Reinforced Concrete Grade 30 as specified

Slabs or the likes;

In floor slab

A 100mm - 150mm Thick 110.00 M3

B Extra for forming 100mm x 50mm deep scupper drain 102.00 M

In suspended hood

C 100mm - 150mm Thick; laid to fall average 105mm thick 18.00 M3

Reinforcement bars; hot rolled deformed high tensile steel

Slabs or the likes

In floor slab

D 10mm Diameter; straight and bent 2071.00 KG

In suspended hood

E 10mm Diameter; straight and bent 1299.00 KG

Reinforcement; fabric; hard drawn plain round steel, welded


as described

Slab or the likes

F In floor slab; Reference B385 1403.00 M2

Class F1 formwork as specified

Slabs or the likes

To soffits of floor slab

G Horizontal 874.00 M2

To sides and soffits of suspended hood

H Horizontal 249.00 M2

13 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:UPPER FLOOR (Contd)

:ELECTRICAL INSTALLATIONS (Contd)

ELECTRICAL INSTALLATIONS

BUILDERS WORK

Builders work in connection with Electrical Installations in


new structures

Fan hook

A 12mm Diameter mild steel rod cast into floor as fan hook 12.00 NO
550mm long bent at centre into U-shape including all
necessary paint work to exposed hook

14 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:UPPER FLOOR

B03/13

B03/14

15 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

ROOF

CONCRETE WORK

IN-SITU CONCRETE

Reinforced Concrete Grade 30 as specified

Slabs or the likes;

In roof slab

A 100mm - 150mm Thick 6.00 M3

Reinforcement bars; hot rolled deformed high tensile steel

Slabs or the likes

In roof slab

B 10mm Diameter; straight and bent 446.00 KG

Reinforcement; fabric; hard drawn plain round steel, welded


as described

Slab or the likes

C In roof slab; Reference B385 46.00 M2

Class F1 formwork as specified

Slabs or the likes

To soffits of roof slab

D Horizontal 46.00 M2

BRICKWORK AND BLOCKWORK

SUNDRIES

Gable Ends

Gable ends in common brick as specified in cement and sand


(1:3) mortar including all necessary plastering to pattern and
painting complete all as per drawing No.
JKR(CB)32(SP)800/01/BT/10

E 3500mm x 2500mm High (overall) 2.00 NO

F 7800mm x 2000mm High (overall) 4.00 NO

16 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:ROOF (Contd)

:ROOFING (Contd)

ROOFING

SLATE OR TILE ROOFING

Roofing; concrete interlocking tiles as specified; fixing every


fifth course with requisite screws per tile to 75mm lap; 38mm
x 25mm steel lipped C-section battens fixed with requisite
screws

Coverings

A Sloping, pitch 25 degrees 793.00 M2

B Sloping, pitch 45 degrees 106.00 M2

EXTRA OVER 25 degrees pitch coverings for

C Ridge tiles; bedded and jointed in cement mortar (1:3) 88.00 M

D Hip tiles; bedded and jointed in cement mortar (1:3) 102.00 M

Underlay

E Double sided aluminium foil insulation as specified; laid on 899.00 M2


and including chicken wire netting; lapped 150mm at joints

F 50mm Thick fibre glass insulation as specified; fixed in 310.00 M2


position on and including chicken wire netting with requisite
trying wire

Awning; concrete interlocking tiles as specified; fixing every


fifth course with requisite screws per tile to 75mm lap;100mm
x 50mm rafters; 75mm x 50mm ties; 50mm x 25mm timber
battens;75mm x 25mm bearer; 175mm x 20mm fascia board;
fixed with all necessary angle cleat, rag bolt and bolt; 18
gauge galvanised iron flashing 500mm girth; complete with
all painting work

G Sloping, pitch 25 degrees 13.00 M2

17 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:ROOF (Contd)

:ROOFING (Contd)

SHEET METAL FLASHINGS AND GUTTERS

Flashings; galvanised iron sheet as specified

No. 18 gauge flashings; 150mm lapped joints; fixing with


matching clips and wedges

A 500mm Girth; one ends wedging into grooves; other ends 31.00 M
dressing along corrugations of concret tiling

WOODWORK

BOARDING AND FLOORING

Wrot pressure treated Group `B' timber as specified

Boarding to eaves, verges, fascias or the like, tongued,


grooved and veed joints

B 30mm thick x 320mm wide board 193.00 M

STRUCTURAL STEELWORK

FABRICATED

Weldable steel; hot rolled sections; welded fabrication and


bolted site connections

`PATENTED' proprietary roof trusses system

Notes: 1.00 xx

The Contractor shall be responsible for the design, supply, 1.00 xx


fabrication, installation and guarantee of the roof truss system
in accordance to the Guidelines and Specification

The Contractor shall submit with his Tender Preliminary 1.00 xx


Design Proposals for the proprietary trusses system duly
certified by the manufacturer approved by the Government,
together with all other relevant submissions stipulated

The proposed design shall be approved by the S.O. prior to 1.00 xx


fabrication and installation on site. The S.O. reserves the right
to make any changes/amendments to the proposed design.
Any such changes/amendments shall be at the cost of the
Contractor

18 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:ROOF (Contd)

:STRUCTURAL STEELWORK (Contd)

The Contractor shall also allow in his rates/prices for any 1.00 xx
additional structures, rafters, chord, bearers, tie, strut, wall
plate, truss connectors, straps, bolts and nuts, or other
associated members which are required solely to
accommodate or support his proposed roof trusses and which
are not provided for in the tender drawings

A `PATENTED' roof trusses for pitch roof complete with Item


dormers; with and including all necessary supports as
indicated based on relevant drawings and as specified; overall
area approximately 800m2 (measured flat on plan) including
design, built, supply, erection, hoisting and fixing in position
10.80m from ground level

PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS

RAINWATER INSTALLATION; GUTTERWORK

uPVC box gutters and fittings; push fit connector joints;


gutterwork and supports self coloured grey as specified

190 mm x 150mm; joints in the running length; supports at


average 500mm centres

B In standard fascia brackets fixed with galvanized screws to 130.00 M


timber

C EXTRA OVER for stopped ends 14.00 NO

D EXTRA OVER for angles 8.00 NO

E EXTRA OVER for outlets for 100mm pipe 16.00 NO

RAINWATER INSTALLATION; PIPEWORK

uPVC pipes and fittings; push fit joints; pipework and


supports self coloured grey as specified; externally

100mm pipework; joints in the running length

F In standard bracket including all necessary fixings fixed to 144.00 M


wall or column

G EXTRA OVER for swan neck 8.00 NO

H EXTRA OVER for bend 16.00 NO

19 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:ROOF (Contd)

:PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS (Contd)

100mm pipework; joints in the running length; embedded in


the concrete or screed

A Laid in position 18.00 M

100mm Diameter pipework; joints in the running length;


embedded in the concrete or screed

B 100mm Diameter stainless steel floor trap with the `elephant 16.00 NO
receiver' cast into concrete including all necessary boxing and
mortar as specified

PAINTING AND DECORATING

NEW WORK

Woodwork

Knot and stop, prime and enamel paint as specified

C General surfaces of timber; over 300mm Girth 68.00 M2

20 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:ROOF

B03/16

B03/17

B03/18

B03/19

B03/20

21 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

EXTERNAL WALL AND BALUSTRADING

CONCRETE WORK

IN-SITU CONCRETE

Reinforced Concrete Grade 30 as specified

Beams or the likes;

A In copings 1.00 M3

Reinforcement bars; hot rolled deformed high tensile steel

Columns or the likes;

In coping

B 10mm Diameter; straight and bent 49.00 KG

Class F1 formwork as specified

Beams or the likes

To sides and soffits of coping

C Horizontal; soffits less than 1.00m high 8.00 M2

BRICKWORK AND BLOCKWORK

NON-LOAD BEARING SUPERSTRUCTURE

Common bricks as specified; in cement mortar (1:3)

Walls

D Half brick thick; stretcher bond 726.00 M2

E One brick thick; English bond 46.00 M2

Balustrade walls

F Half brick thick; stretcher bond 84.00 M2

Walls for Dormer

G Half brick thick; stretcher bond 17.00 M2

H 2500mm Width x 1100mm high half brickwall with 4.00 NO


decorative mild steel railing type ST2/A/2; concrete projection
around edge; complete with plaster and painting on both sides
all per drawing JKR(CB)32(SP)900/01/BT/1

Sundries

J 40mm Diameter UPVC outlet pipe as specified 28.00 NO

22 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:EXTERNAL WALL AND BALUSTRADING (Contd)

:BRICKWORK AND BLOCKWORK (Contd)

Damp proof course as specified; 100 laps; bedding in cement


mortar (1:3); no allowance in measurement for laps

On horizontal surfaces

A Over 225mm wide 3.00 M2

B 115mm Wide 240.00 M

METALWORK

BALUSTRADES STAIRCASES

Mild steel in welded joints as specified

Mild steel decorative railing consisting of 50mm x 40mm x


3.2mm thick hollow top rail fixed to 38mm x 6mm thick
balustrade and 12mm x 3.2mm thick baluster welded all
members together all as per drawing No.
JKR(CB)32(MS)900/02/ST(1)/1-3

C Type ST2/A/1 size 600mm x 600mm fixed into concrete 4.00 NO

D Type ST2/A/2 size 1200mm x 600mm fixed into concrete 8.00 NO

E Type ST2/A/3 size 1800mm x 600mm fixed into concrete 4.00 NO

23 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:EXTERNAL WALL AND BALUSTRADING

B03/22

B03/23

24 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

WINDOWS, VENTS AND EXTERNAL DOORS

METALWORK

DOORS

DOOR IN METAL FRAMING COMPLETE WITH


ASSOCIATED IRONMONGERIES/ ACCESSORIES AND
PAINTING WORKS AS DESCRIBED

Fire Rated Door

A Type PA; overall size 900mm x 2200mm 4.00 NO

B Type PA1; overall size 1500mm x 2200mm 1.00 NO

DOOR IN ZINC COATED STEEL FRAMING COMPLETE


WITH ASSOCIATED IRONMONGERIES/ ACCESSORIES
AND PAINTING WORKS AS DESCRIBED

Single leaf flush door with fixed louvred vent on top

C Type P15; overall size 750mm x 2700mm 4.00 NO

D Type P15a; overall size 750mm x 2700mm 12.00 NO

WINDOWS

WINDOW IN ZINC COATED STEEL FRAMING


COMPLETE WITH GLAZING WORK AND ASSOCIATED
IRONMONGERIES/ ACCESSORIES AS DESCRIBED

Louvred window; consisting of 2 nos fixed glass louvred


panels on top and 2 nos adjustable glass louvred panels on
bottom; assembling and fixing by bolting and screws as
described as per drawing
no.JKR(CB)32(SP)900/01/JPT/1A-13 JI/1-4

E Type T2; overall size 1200mm x 1700mm 2.00 NO

Louvred window; consisting of 3 nos fixed glass louvred


panels on top and 3 nos adjustable glass louvred panels on
bottom; assembling and fixing by bolting and screws as
described as per drawing
no.JKR(CB)32(SP)900/01/JPT/1A-13 JI/1-4

F Type T1; overall size 1800mm x 1700mm 5.00 NO

Fixed louvred window; consisting of 4 nos fixed glass louvred


panels; assembling and fixing by bolting and screws as
described as per drawing
no.JKR(CB)32(SP)900/01/JPT/1A-13 JI/1-4

G Type L1; overall size 2400mm x 500mm 41.00 NO

25 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:WINDOWS, VENTS AND EXTERNAL DOORS (Contd)

:METALWORK (Contd)

Casement window; consisting of 3 nos top hung vent on top


and 2 nos fixed glass panel with 1 nos sliding window on
bottom; assembling and fixing by bolting and screws as
described as per drawing
no.JKR(CB)32(SP)900/01/JPT/1A-13 JI/1-4

A Type T4g; overall size 1800mm x 1700mm 12.00 NO

COMPOSITE WINDOWS AND DOORS

WINDOWS AND DOORS IN ZINC COATED STEEL


FRAMING IN-FILL WITH CONCRETE, COMPLETE
WITH GLAZING WORKS AND ASSOCIATED
IRONMONGERIES/ ACCESSORIES AND PAINTING
WORKS AS DESCRIBED

Timber flush door with 3 nos fixed glass panel on top; 2 nos.
fixed glass panel one side; coupling mullion; assembling and
fixing by bolting and screw complete with mild steel
decorative grille

B Type P9a; overall size 2050mm x 2700mm 4.00 NO

Timber flush door with 2 nos fixed glass louvred on top; 1


nos. adjustable louvred window one side; coupling mullion;
assembling and fixing by bolting and screw

C Type P5; overall size 1500mm x 2700mm 1.00 NO

Pair timber flush door with top hung casement on top; 1 nos.
fixed glass panel both sides; coupling mullion; assembling and
fixing by bolting and screw complete with mild steel
decorative grille

D Type P2g; overall size 2100mm x 2700mm 4.00 NO

Timber flush door with 3 nos. fixed glass louvered panel on


top; coupling mullion; assembling and fixing by bolting and
screw

E Type P4; overall size 2100mm x 2700mm 3.00 NO

F Type P4a; overall size 2100mm x 2700mm 8.00 NO

26 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:WINDOWS, VENTS AND EXTERNAL DOORS (Contd)

:METALWORK (Contd)

Timber flush door with 1 nos. fixed glass louvered panel on


top; coupling mullion; assembling and fixing by bolting and
screw

A Type P16; overall size 1200mm x 2700mm 2.00 NO

27 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:WINDOWS, VENTS AND EXTERNAL DOORS

B03/25

B03/26

B03/27

28 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

INTERNAL WALL

CONCRETE WORK

IN-SITU CONCRETE

Reinforced Concrete Grade 30 as specified

Columns or the likes;

A In stiffeners 1.00 M3

Reinforcement bars; hot rolled plain round mild steel

Columns or the likes;

In stiffeners

B 6mm Diameter; straight and bent 194.00 KG

Reinforcement bars; hot rolled deformed high tensile steel

Columns or the likes;

In stiffeners

C 12mm Diameter; straight and bent 111.00 KG

Class F1 formwork as specified

Columns or the likes

D To sides of stiffeners 13.00 M2

BRICKWORK AND BLOCKWORK

NON-LOAD BEARING SUPERSTRUCTURE

Common bricks as specified; in cement mortar (1:3)

Walls

E Half brick thick; stretcher bond 557.00 M2

Damp proof course as specified; 100 laps; bedding in cement


mortar (1:3); no allowance in measurement for laps

On horizontal surfaces

F 115mm Wide 182.00 M

29 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:INTERNAL WALL (Contd)

:METALWORK (Contd)

METALWORK

PARTITION

Gypsum board partition

Alcom or approved equivalent aluminium framing comprising


of 13mm thick gypsum board and 13mm thick clear float glass
complete with all associated accessories and finishing works
all as per manufacturer's Instruction and drawing no.
JKR(CB)32(SP)900/01/JPT/5-6

A 1200mm x 3600mm High overall (Type S15) 4.00 NO

B 2000mm x 3100mm High overall (Type S17) 1.00 NO

C 2000mm x 3600mm High overall (Type S16) 2.00 NO

D 2800mm x 3100mm High overall (Type S6) 2.00 NO

E 3000mm x 3600mm High overall (Type S1) 1.00 NO

F 3000mm x 3600mm High overall (Type S18) 1.00 NO

G 4500mm x 3100mm High overall (Type S19) 1.00 NO

30 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:INTERNAL WALL

B03/29

B03/30

31 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

INTERNAL DOORS

CONCRETE WORK

IN-SITU CONCRETE

Reinforced Concrete Grade 30 as specified

In heel stone

A 50mm x 150mm x 150mm High cast to profile of door frame 48.00 NO


including all necessary formwork as specified

METALWORK

DOORS

DOOR IN METAL FRAMING COMPLETE WITH


ASSOCIATED IRONMONGERIES/ ACCESSORIES AND
PAINTING WORKS AS DESCRIBED

Fire Rated Door

B Type PA; overall size 900mm x 2200mm 2.00 NO

C Type PA1; overall size 1500mm x 2200mm 2.00 NO

DOOR IN ZINC COATED STEEL FRAMING COMPLETE


WITH ASSOCIATED IRONMONGERIES/ ACCESSORIES
AND PAINTING WORKS AS DESCRIBED

Single leaf flush door with fixed louvred vent on top

D Type P15; overall size 750mm x 2700mm 4.00 NO

PVC Door

E Type P14; overall size 850mm x 2200mm 48.00 NO

COMPOSITE WINDOWS AND DOORS

WINDOWS AND DOORS IN ZINC COATED STEEL


FRAMING IN-FILL WITH CONCRETE, COMPLETE
WITH GLAZING WORKS AND ASSOCIATED
IRONMONGERIES/ ACCESSORIES AND PAINTING
WORKS AS DESCRIBED

Pair timber flush door with top hung casement on top; 1 nos.
fixed glass panel both sides; coupling mullion; assembling and
fixing by bolting and screw complete with mild steel
decorative grille

F Type P2g; overall size 2100mm x 2700mm 4.00 NO

32 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

EXTERNAL FLOOR FINISHES

FLOOR, WALL AND CEILING FINISHINGS

FLOOR

In situ Finishings

Cement and sand (1:3) rendering type `Power Float'

A 20mm Thick to floor; level, falls and crossfalls and to slope 425.00 M2
not exceeding 15 degrees from horizontal

33 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

INTERNAL FLOOR FINISHES

WATERPROOFING AND ASPHALT WORK

DAMP PROOFING AND TANKING

Damp Proof Membrane as specified

Coverings; to concrete base

A Over 300mm wide; flat; subsequently covered 132.00 M2

FLOOR, WALL AND CEILING FINISHINGS

FLOOR

In situ Finishings

Cement and sand (1:3) rendering as specified; trowelled


smooth

B 20mm Thick to floor; level, falls and crossfalls and to slope 409.00 M2
not exceeding 15 degrees from horizontal

Cement and sand (1:3) waterproofed rendering as specified;


trowelled smooth

C 20mm Thick to floor; level, falls and crossfalls and to slope 12.00 M2
not exceeding 15 degrees from horizontal

Tile, Slab and Block Finishing

Semi-glazed ceramic floor tiles, 150mm x 150mm as


specified; bedded and jointed in cement mortar (1:3); pointing
with grout in white cement; on and including 20mm thick
cement and sand (1:3) screeded bed

D Floor, level, falls and crossfalls and to slope not exceeding 15 258.00 M2
degrees from horizontal

E 150mm x 100mm x 6mm Thick to skirtings; with bull nose on 393.00 M


edge

Semi-glazed ceramic floor tiles, 300mm x 300mm x 7.5mm as


specified; bedded and jointed in cement mortar (1:3); pointing
with grout in white cement; on and including 20mm thick
cement and sand (1:3) screeded bed

F Floor, level, falls and crossfalls and to slope not exceeding 15 459.00 M2
degrees from horizontal

G 300mm x 100mm x 7.5mm Thick to skirtings; with bull nose 83.00 M


on edge

34 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

EXTERNAL CEILING FINISHES

WOODWORK

FRAMEWORK

Sawn pressure treated Group `B' timber as specified

Framework to form false ceiling; to receive cement board


finish

A over 300mm wide; 50mm x 100mm members at 610mm 252.00 M2


centres one way; 50mm x 50mm subsidiary members at
1220mm centres one way

FLOOR, WALL AND CEILING FINISHINGS

CEILING

Plastering

Cement and sand (1:6) with an approved plasticiser as


specified, trowelled finish to sides and soffit of beams and
concrete slab; 20mm - 3.5m above ground level

B 20mm Thick; level, falls, falls and crossfalls and to slope not 182.00 M2
exceeding 15 degrees from horizontal

Cement and sand (1:6) with an approved plasticiser as


specified, trowelled finish to top, sides and soffits of hood

C 20mm Thick; level, falls, falls and crossfalls and to slope not 303.00 M2
exceeding 15 degrees from horizontal

Ceiling Board

Suspended ceilings; Cement Board ceiling as specified;


1220mm x 610mm x 6mm Thick fixed to ceiling joist and
spacer (measured separately) and including all necessary
timber beading

D Linings to ceilings; level, falls, falls and crossfalls and to 252.00 M2


slope not exceeding 15 degrees from horizontal

E EXTRA OVER for forming 600mm x 600mm access panel 5.00 NO


and including all necessary framing

35 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:EXTERNAL CEILING FINISHES (Contd)

:PAINTING AND DECORATING (Contd)

PAINTING AND DECORATING

NEW WORK

Ceiling Finishes

Acrylic weathershield paint as specified

A To soffit of plastered suspended slab and beams; over 300mm 182.00 M2


girth

B On ceiling board; over 300mm girth 252.00 M2

C To sides and soffit of plastered hood; over 300mm girth 303.00 M2

36 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:EXTERNAL CEILING FINISHES

B03/35

B03/36

37 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

INTERNAL CEILING FINISHES

WOODWORK

FRAMEWORK

Sawn pressure treated Group `B' timber as specified

Framework to form false ceiling; to receive cement board


finish

A over 300mm wide; 50mm x 100mm members at 610mm 631.00 M2


centres one way; 50mm x 50mm subsidiary members at
1220mm centres one way

FLOOR, WALL AND CEILING FINISHINGS

CEILING

Plastering

Cement and sand (1:6) with an approved plasticiser as


specified, trowelled finish to sides and soffit of beams and
concrete slab; 20mm - 3.5m above ground level

B 20mm Thick; level, falls, falls and crossfalls and to slope not 732.00 M2
exceeding 15 degrees from horizontal

Ceiling Board

Suspended ceilings; Cement Board ceiling as specified;


1220mm x 610mm x 6mm Thick fixed to ceiling joist and
spacer (measured separately) and including all necessary
timber beading

C Linings to ceilings; level, falls, falls and crossfalls and to 632.00 M2


slope not exceeding 15 degrees from horizontal

D EXTRA OVER for forming 600mm x 600mm access panel 8.00 NO


and including all necessary framing

PAINTING AND DECORATING

NEW WORK

Ceiling Finishes

Emulsion paint as specified

E On ceiling board; over 300mm girth 632.00 M2

F To soffit of plastered suspended slab and beams; over 300mm 732.00 M2


girth

38 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

EXTERNAL WALL FINISHES

FLOOR, WALL AND CEILING FINISHINGS

WALL

Plastering

Cement and sand (1:6) plainface plaster mixed with an


approved plasticiser as specified; steel trowelled

A 20mm Thick work to walls on brickwork, column, blockwork 64.00 M2


or concrete work base for dormer wall

B 20mm Thick work to walls on brickwork, blockwork or 772.00 M2


concrete work base

C 20mm Thick work to balustrade walls on brickwork, column, 238.00 M2


blockwork or concrete work base

Decorative cornice (birai hias)

D 150mm x 75mm precast concrete decorative cornice fixed to 11.00 M


dormer wall complete with all painting works

PAINTING AND DECORATING

NEW WORK

Wall Finishes

Acrylic weathershield paint as specified

E On plastered wall; over 300mm girth 772.00 M2

F On plastered wall, column and beam; over 300mm girth for 64.00 M2
dormer wall

G On plastered balustrade wall with approved pattern; over 238.00 M2


300mm girth (measured flat overall)

Metalwork

Red iron oxide metal primer and high gloss enamel paint as
specified

H General surfaces of metal; over 300mm girth (measure flat 23.00 M2


overall)

39 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

INTERNAL WALL FINISHES

FLOOR, WALL AND CEILING FINISHINGS

WALL

Plastering

Cement and sand (1:6) plainface plaster mixed with an


approved plasticiser as specified; steel trowelled

A 20mm Thick work to walls on brickwork, blockwork or 1082.00 M2


concrete work base

Tile work

Semi-glazed ceramic wall tiles 150mm x 150mm x 6mm thick


as specified in approved colour and pattern, bedded jointed
and pointed in cement mortar (1:3); on and including 20mm
thick cement and sand (1:3) screeded backing complete with
two layers of approved damp proof membrane

B Tiled to wall 314.00 M2

PAINTING AND DECORATING

NEW WORK

Wall Finishes

Emulsion paint as specified

C On plastered wall; over 300mm girth 1082.00 M2

40 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

SANITARY FITTINGS

PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS

SANITARY INSTALLATION; FITTINGS

Supply and fix the following Sanitary Fittings and accessories,


including jointing and connecting to services and soil and
waste pipes and making good all work disturbed; internally

Basin

A Approved 560mm x 410mm in vitreous china for with one 28.00 NO


12mm diameter chromium-plated tap, one vitreous china
blank tap hole stopper, 31mm diameter chromium-plated
waste outlet fitting with plug, chain and stay, 31mm diameter
bottle trap with 75mm seal and set in opening in concrete
worktop including making good tiled work

B Approved 500mm x 410mm handrinse basin (disable user) in 2.00 NO


white glazed vitreous china with one left hand taphole, no
overflow, 32mm unslotted strainer waste, 13mm diameter
bottle trap with 75mm deep seal including jointing outlet to
waste pipe, fixing bracket and sealing with mastic sealant

Water Closet

C Approved squatting flush valve suite in white vitreous china 32.00 NO


pan with S or P trap; complete with pair of tread plates, flush
valve system without pump, push button, vacum breaker,
elbow flush connection, adjustable tailpiece, dual filtered, one
flush depress and hold feature, exposed parts hard chrome
plated; bedding pan in concrete bed and including working or
making good floor and wall tiling around.

D Padestal Water Closet (disable user) talbot pan 510mm high, 2.00 NO
bakasan open front, no cover Flush valve suites; without
pump, push button, vacum breaker, elbow flush connection,
adjustable tailpiece, dual filtered, one flush depress and hold
feature, exposed parts hard chrome plated, pan with S or P
trap conversion bend, setting pan in tiled concrete floor

41 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:SANITARY FITTINGS (Contd)

:PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS (Contd)

Cistern

A Salona cistern and civer (disable user) 6/3 litres capacity for 2.00 NO
side supply and overflow, reversible lever, freeflow plastic
syphon fittings with 13mm microvalve HP/LP ballvalve, side
supply, 20mm side overflow, simplainlet connector and
supports and plastic flushpipe

Shower

B Approved equivalent stainless steel shower fittings complete 8.00 NO


with 13mm diameter stop cock, riser pipe with 100mm
diameter shower rose pipe and fixed to tiled wall

Soap Holder

C Approved equivalent 150mm x 150mm semi recessed dish in 24.00 NO


vitreous china fixed to tiled wall

Mirror

D 600mm x 600mm x 6mm Thick approved bevelled edge plate 30.00 NO


glass complete with 5mm thick waterproof plywood backing
and fixed with chromium plated dome headed fixing screws
and cork washers

Toilet Roll Holder

E 150mm x 150mm Semi recessed toilet roll holder in vitreous 20.00 NO


china complete with plastic roller

Cloth Hook

F Stainless steel hook; screw to wall complete with accessories, 16.00 NO


fixing screws and plug

Hinged Support Rail (disable user)

G Stainless steel bar screw to tiled wall 2.00 NO

Grab Rail (disable user)

H 600mm Long in stainless steel bar fixed to tiled wall 2.00 NO

42 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:SANITARY FITTINGS (Contd)

:PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS (Contd)

A 700mm Long in stainless steel bar fixed to tiled wall 2.00 NO

Tap and Hand Bidet

B Approved 13mm diameter chrome plated inclined bib tap with 32.00 NO
flexible hose and stainless steel clips, ball lever handle and
quarter turn ceramic disc head parts

Tap (disable user)

C 13mm Diameter chrome plated lever action spray mixer tap 2.00 NO

Floor Trap

D Approved 150mm x 150mm stainless steel with cover and 42.00 NO


`Elephant Receiver', water stop sleeves to floor slab opening
complete with grouted to waterproof

43 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:SANITARY FITTINGS

B03/41

B03/42

B03/43

44 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

PLUMBING INSTALLATION

PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS

COLD WATER INSTALLATION; PIPEWORK

Cold Water System; internally

UPVC pipes as specified

A Supply pipes and fittings, from and including first stopcock Item
from incoming mains to water storage tanks to sanitary
appliances and scour and overflow pipes from water storage
tanks, including all necessary excavation, connections with
requisite connectors to water storage tank and sanitary
appliances, requisite pipe fittings, stopcock and requisite
openings and holes in roof, floors and all other necessary
works as per drawing no. PBA B/60/2-10 and PBA H/437/3-4

Storage Water Tank

High Density Polyethylene (HDPE) water tank as specified


complete with all accessories and fittings of approved
manufacturer to JBA approval, hoisted and placed in position
at approximately 10800mm above ground level on and
including RSJ support all in accordance to manufacturer's
instruction

B 2500mm Diameter x 1000mm high 4.00 NO

SANITARY INSTALLATION PIPEWORK

Soil, Waste and Vent Pipes; internally

UPVC pipes as specified

C Waste water, soil and vent pipes with and including all Item
requisite fittings from sanitary appliances and from floor traps
and outlet grating to connecting manholes or water channel
drains including all necessary excavation, concrete casing
around pipework, connections with requisite connectors to
sanitary appliances, requisite openings, requisite to chase, in
roof, floors, beams and wall, and other all necessary work as
per drawing no. PBA.B/60/12 - 15

45 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:PLUMBING INSTALLATION (Contd)

:PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS (Contd)

TESTING

Cold Water Installation; Soil, Waste and Vent Pipes; Sanitary


Installation

Pipework and Fittings

A On completion of the plumbing and sanitary installation test Item


all appliances, pipes and fittings, make good any defects and
leave the whole in perfect working order to the approval of the
Superintending Officer.

46 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:PLUMBING INSTALLATION

B03/45

B03/46

47 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

BUILDERS WORK IN CONNECTION

PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS

BUILDER'S WORK

Stool

Plain Concrete Grade 15 as specified

A 150mm - 300mm thick 5.00 M3

Class F1 formwork as specified to edge of

B Not exceeding 250mm high 28.00 M

Semi-glazed ceramic floor tiles, 150mm x 150mm x 6mm as


specified; bedded and jointed in cement mortar (1:3); pointing
with grout in white cement; on and including 20mm thick
cement and sand (1:3) screeded bed

C Floor; level, falls and crossfalls and to slope not exceeding 15 24.00 M2
degrees from horizontal

D Edges of bed; not exceeding 250mm thick 28.00 M

Basin Worktop

75mm Thick concrete top to receive wash hand basin


(measured separately) including all necessary formwork; a
layer of mesh fabric reinforcement; half brick thick wall
support finished with 150mm x 150mm ceramic wall tiles;
concrete top finished with 150mm x 150mm ceramic tiles
including tile trimmer around basin and edge of concrete all
as per drawing No. JKR(CB)32(SP)900/01/WC/8

E Overall size 2000mm x 600mm x 800mm High 4.00 NO

F Overall size 4000mm x 600mm x 800mm High 4.00 NO

Concrete Bench

G 3150mm x 450mm x 350mm High (Overall size) `L shaped' 2.00 NO


bench (Type BK) with 75mm thick reinforced concrete slab
with BRC 10 and finish with 150mm x 150mm ceramic tiles
as per drawing no JKR(CB)32(SP)900/02/WC(1)/9

48 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:BUILDERS WORK IN CONNECTION (Contd)

:PLUMBING AND MECHANICAL ENGINEERING


INSTALLATIONS (Contd)

Timber Bench

A 885mm x 235mm x 350mm High timber bench construct from 8.00 NO


75mm x 25mm Wrot Pressure Treated Group `B' timber
screwed to stainless steel bracket including two coats gloss
enamel paint fixed to tiled wall as per drawing no
JKR(CB)32(SP)900/01/WC/9

49 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Collection

:BUILDERS WORK IN CONNECTION

B03/48

B03/49

50 0.00
BLOCK B - ADMINISTRATION AND ACADEMIC BLOCK

:Summary

:WORK BELOW LOWEST FLOOR FINISH

:RAMPS, APRON AND PERIMETER DRAINS

:FRAME

:UPPER FLOOR

:ROOF

:EXTERNAL WALL AND BALUSTRADING

:WINDOWS, VENTS AND EXTERNAL DOORS

:INTERNAL WALL

:INTERNAL DOORS

:EXTERNAL FLOOR FINISHES

:INTERNAL FLOOR FINISHES

:EXTERNAL CEILING FINISHES

:INTERNAL CEILING FINISHES

:EXTERNAL WALL FINISHES

:INTERNAL WALL FINISHES

:FITTINGS AND FURNISHINGS

:SANITARY FITTINGS

:PLUMBING INSTALLATION

:BUILDERS WORK IN CONNECTION