DESCRIPTION

Magnetic level gauge, type: MLG is simply constructed and resistant to adverse condition of temperature and pressure.
Since there are no glasses or Mica sheets as used in the conventional level gauges which may crack or break is some
of the reasons why many industrial users favors this design.
MLG Magnetic level gauge have a construction of material 304SS, 316SS, PVC, CPVC, PP, PVDF or PTFE that using
for most applications in industries such as :
- Chemical, Petrochemical, Oil & Gas and other corrosive process.
- Refrigeration, Retorts and Heat Treatment
- Boilers, Evaporators, Condensers & Storage Tanks
- Marine and Almost all sector Industries.

OPERATION PRINCIPLE
5 4 Magnetic level gauge MLG consist of some important parts that
will be working together as one unit.
The Working principle was simple, a vertical measuring chamber (1)
is connected to the liquid vessel at each end (side to side, side to
bottom, top to bottom) contains a float (2) with a built-in permanent
1 magnet (3) inside that will rises and falls with the liquid level.
The chamber is completely sealed so that the only moving part that
contacts the liquid is the FLOAT itself.
2 On the “DRY SIDE” of the chamber, a magnetic strip indicator (4),
3 a column of bi-color magnetic tabs (5) that form a vertical strip to
provide a visual indication of the fluid level attached.
As the float moves up or down, the permanent magnet mounted in
its top section of float “PULL” the tabs through a rotation of 180 Deg
thus changing their color.
As the float rises the tabs are turned from WHITE to RED and as
the float falls, they changed back to WHITE again.
This means that the liquid level inside the vessel is constantly
represented by a RED strips without using any external power supply.
The Magnetic level gauge MLG can be also equipped with several
choices such as :
- MAGNETIC SWITCH
- LEVEL SENSOR & TRANSMITTER
APPLICATION SAMPLE
DCS or BAS

PLC

OR
4-20mA

4-20mA

WP TU
Digital Meter 2 wire
Transmitter
3 Wire
Potentiometer +

2
MAGNETIC LEVEL GAUGE, 304SS or 316SS

No DESCRIPTION MATERIAL & DATA


1 Vent Plug 304SS or 316SS
1. VENT PLUG 304SS
Plug 1/2” NPT (Standardl)
+ +
Plug 3/4” NPT, Valve or Flange (Optional)
+/- 120
2 Guide Pipe 304SS or 316SS, 2" Sch 10 (Standard)
1 2 4 304SS or 316SS, 2” Sch 20 (Optional)
100

3 Process Conn 304SS or 316SS, Flange JIS, or Screw


ANSI, DIN
3 4 Level Transmitter 304SS
Screw, /NPT
316SS , Sensor
or BSP MaleTube
or Female
(OPTIONAL)
4 Level Transmitter Aluminium
304SS / 316SS IP-68, Housing or Ex-proof
Sensor Tube
(OPTIONAL) Output 4-20IP-68
Aluminium mA, Housing
2 wire system, 24Vdc
or Ex-proof
5 Output
or 3 Wire
4-20
Potentiometer
mA, 2 wire system, 24Vdc
5 Flapper Clamp 304SS or 3 Wire Potentiometer
56 Flapper Clamp
Rail 304SS
Aluminium, Max length = 6000mm
67 Flapper Rail Aluminium, GF,
Indicator PA66+30% MaxRed length = 6000mm
+ White & Yellow
6 78 Flapper
MagneticIndicator
Switch PA66+30% GF, GF orRed + WhiteAlum
Ex-Proof & Yellow
L

7
8 Magnetic
(OPTIONAL)Switch SPDT
PA66+30%
Reed GF or Ex-Proof
Contact, Alum
1A, 230 VAC/DC
9 (OPTIONAL)
Flapper Cover SPDT Reed Contact, 1A, 230 VAC/DC
PA66+30%GF
9 Flapper Cover PA66+30%GF
10 Flange Bottom 304SS/316SS
10 Flange Bottom 304SS/316SS
Flange, 2" JIS 10K (Standard)
Flange,
Optional2"2”JIS 10K150RF
ANSI (Standard)
or 300 RF
8 11 Drain Valve/Plug 304SSOptionalor2”316SS,
ANSI 150RF or 300 RF
11 Drain Valve/Plug 304SS or 316SS,
Plug 1/2" NPT (Standard)
Plug 1/2"
3/4” NPT or (Standard)
Valve (Optional)
9 12 CM Scale Plug 3/4” NPT or
Aluminium + Acrylic Valve
OR (Optional)
13 12 (OPTIONAL)
CM Scale Aluminium
304SS Plate+ Acrylic OR
with Etching
LF

12 (OPTIONAL)
13 Magnet Float 304SS
FMS = Plate
316LSS with Etching
10 13 Magnet Float FMS 316LSS
FMT = Titanium
FMT = Titanium
L = Length ( C to C) , Up to 5700 mm (Straight Pipe)
+/- 100

L = Length ( C to C) , Up to 5700
22000mm mm(Straight Pipe)Pipe)
(Connecting
, Up to 22000 mm (Connecting Pipe)
11
Pressure
Pressure / Temp Max == 16
/ Temp Max 16 Barg
Barg // 200
200 ºCºC (Standard)
(Standard)
Higher
Higher Pressure and Temperature available on
Pressure and Temperature available on Request
Request

FLOATS & DIMENSION L


Ø

PRESS MAX TEMP MAX DENSITY L Ø LF


MODEL MATERIAL APPLICATION
(Barg) (ºC) (Kg/m3) (mm) (mm) (mm)
FMS-160 316LSS 16 200 900 160 50 ± 110 Water, Hot Water, Chemical etc
FMS-200 316LSS 16 200 800 200 50 ± 150 Diesel Fuel, Oil etc
FMS-250 316LSS 16 200 700 250 50 ± 200 Fuel Oil, chemical etc
FMS-300 316LSS 16 200 650 300 50 ± 250 Low Density Liquids
900 800 800 - 1000
FMS-300/HT 316LSS 16 350 800 300 50 ± 250 Hot Thermal Oil
FMT-400 TITANIUM 16 200 450 400 50 ± 350 LPG (Liquids) or Other Gas Liquids

3
MAGNETIC LEVEL GAUGE, PVC or CPVC

4
1 +/- 130 No DESCRIPTION MATERIAL & DATA
1 Upper Cover PVC or CPVC 2” Cap (Standard)
+/- 130 1. VENT PLUG 304SS
PVC or CPVC 2” Union (Optional)
2 Tee Connection PVC or CPVC 2” Sch 80 (Standard)
2 3 Process Conn PVC or CPVC, Flange JIS, DIN or ANSI
4 Level Transmitter PVC or CPVC ½” Sch 80, Sensor Tube
(OPTIONAL) PP Housing IP-65 (Standard)
3 Output 4-20 mA, 2 wire system, 24Vdc
5 or 3 Wire Potentiometer
5 Flapper Clamp 304SS
6 Guide Pipe PVC or CPVC, 2” Sch 80
7 Flapper Rail Aluminium
8 Flapper Indicator PA66+30% GF, Red + White & Yellow
6 9 Magnetic Switch PA66+30% GF or Aluminium Ex-Proof
7 (OPTIONAL) SPDT Reed Contact, 1A, 230 VAC/DC
L

10 Flapper Cover PA66+30% GF


8 11 Bottom Cover PVC or CPVC, Union 2” Sch80(Standard)
Flange JIS, ANSI or DIN (Optional)
12 CM Scale Aluminium + Acrylic
(OPTIONAL)
13 Magnet Float FMPP = PP (Polypropelene)
9 FMDF = PVDF

L = Length ( C to C) , Up to 5700 mm (Straight Pipe)


, Up to 10000 mm (Connecting Pipe)
10 12 Pressure / Temp Max = 3 Barg / 50 ºC (PVC)
13 Pressure / Temp Max = 3 Barg / 80 Deg C (CPVC)
LF

11

FLOATS & DIMENSION L


Ø

PRESS MAX TEMP MAX DENSITY L Ø LF


MODEL MATERIAL APPLICATION
(Barg) (ºC) (Kg/m3) (mm) (mm) (mm)
FMPP-160 PP 3 80 900 160 45 ± 130 HCL, NaOH and other Chemicals
FMDV-180 PVDF 3 100 900 180 45 ± 150 H2SO4 & Strong Acids
For Floats Request not in our standard dimension, please contact and Discuss.

4
TOP MOUNTING MAGNETIC LEVEL GAUGE, 304SS or 316SS

+ No DESCRIPTION MATERIAL & DATA


1 1 Vent Plug 304SS or 316SS
2
1. VENT PLUG 304SS
Plug 1/2” NPT (Standardl)
3 Plug 3/4” NPT, Valve or Flange (Optional)
4
GuideTransmitter
2 Level Pipe 304SS or 316SS, Sensor 2" Sch 10
Tube(Standard)
5 (OPTIONAL) 304SS or 316SS,
Aluminium 2” Sch 20
IP-68 Housing (Optional)
or Ex-proof
3 Process Conn 304SS
Output or 316SS,
4-20 mA, 2Flange or Screw
wire system, 24Vdc
4 Level Transmitter 304SS / 316SS
or 3 Wire , Sensor Tube
Potentiometer
3 (OPTIONAL)
Guide Pipe Aluminium IP-68 Housing
304SS or 316SS, 2" Sch 10or (Standard)
Ex-proof
6
Output
304SS 4-20 mA, 22”wire
or 316SS, Schsystem, 24Vdc
20 (Optional)
4 Cm Scale or 3 Wire Potentiometer
Aluminium + Acrylic OR
7 5 Flapper Clamp 304SS or 316SS Etching plate
(OPTIONAL)
65 Flapper Rail
Clamp 304SS Aluminium, Max length = 6000mm
76 Flapper Indicator
Rail PA66+30%
Aluminium, GF,MaxRed + White
length & Yellow
= 6000mm
87 Magnetic Switch PA66+30% GF,
Flapper Indicator GF orRed Ex-Proof
+ WhiteAlum
& Yellow
8 8 (OPTIONAL)
Magnetic Switch SPDT Reed GF
PA66+30% Contact, 1A, 230
or Ex-Proof VAC/DC
Alum
9 Flapper Cover
(OPTIONAL) PA66+30%GF
SPDT Reed Contact, 1A, 230 VAC/DC
109 Flange
FlapperBottom
Cover PA66+30%GF
304SS/316SS
10 Flange Conn 304SS/316SS
Flange, 2" JIS 10K (Standard)
9
Flange,
Optional1"2”JIS 10K150RF or 300 RF
ANSI
10 11 Process Conn 304SS or
Drain Valve/Plug 304SS or 316SS, 316SS,Flange 4” JIS 10K,
80

4” ANSI
Plug 1/2"150RF or DN100/PN16
NPT (Standard)
11 12 Float Rod 316SS,
Plug 3/4”Rod
NPT= or
5mm or Tube
Valve (Optional)
13
12 Float
CM Scale FMSG = 316LSS
Aluminium + Acrylic OR
(OPTIONAL) 304SS Plate with Etching
12 13 Magnet Float FMS = 316LSS
L = LengthFMT = Titanium
, Maximum up to 3000 mm
L = Length ( C to C)
Pressure , Up to
/ Temp Max5700
= 16mm
Barg (Straight Pipe)
/ 200 ºC
, Up to 22000 mm (Connecting Pipe)
L

13
Ø

L
FLOATS & DIMENSION

PRESS MAX TEMP MAX DENSITY L Ø


MODEL MATERIAL APPLICATION
(Barg) (ºC) (Kg/m3) (mm) (mm)
FMSG-250 316SS 16 200 600 150 90 Water, Oil, NaOH and other Chemicals

For Floats Request not in our standard dimension, please contact and Discuss.

5
MAGNETIC FLAPPER INDICATOR, FPA
Magnetic level gauge will be equipped with magnetic flapper
as an standard indicator.
The type of flapper flapper plastic type (FPA) with high temp
plastic which can withstand temp working up to 250 Deg C.
The flapper color are white, red and yellow.

No DESCRIPTION MATERIAL & DATA


1 HOUSING Aluminium Anodized

2 FLAPPER PA-66 + 30% GF

3 COLORS White, Red & Yellow

4 COVER Polycarbonate or Glass

5 TEMP MAXIMUM 250 Deg C

6 PROTECTION RATING IP-65

7 OPTIONAL SCA = Cm Scale, Acrylic


SCS = Cm Scale, SS

MAGNETIC SWITCH, MS & MS-Ex


Magnetic switch MS is a switch unit that mounted at the side of WINGEL MLG magnetic level gauge.
The magnetic switch MS can be used for controlling pumps in emptying or filling processes as well as monitoring high
or low alarms. The MS mounted at the aluminum flapper rail and can be adjusted at any position with easy slide movement.
Wingel have 2 type of magnetic switch, the general type: MS and with explosion proof housing, MS-Ex.

MODEL MS MS-Ex
BODY MATERIAL PA-66 + 30% GF Aluminium Alloy
PROTECTION RATING IP-65 Eexd IIC T6, ATEX, IP-65
CONTACT OUTPUT Change Over, SPDT, Bistable, 1A, 230VAC/DC, 40VA
TEMPERATURE MAXIMUM 200 Deg C 125 Deg C
TERMINAL HOUSING DIN Plug, Polyamid, IP-65 Aluminium Ex-proof
CABLE ENTRY PG-9 with Gland ½” NPT-F
70

50

MS

73
100
75 87
70

MS-EX

6
LEVEL SENSOR & TRANSMITTER, LTS

Magnetic level gauge MLG also can be equipped with level sensor model:
LTS-MLG.
LTS-MLG is a reed type level sensor clamped on the MLG level gauge to
provide continous output of 3 wire potentiometer signal connected to digital
meter type: WP4 or WP5 will be giving a continous digital display reading .
It is also can be connected to TU, 2 wire transmitter that provide 4-20 mA
output signal to PLC or DCS or others.
For hazardous location, the LTS can be use transmitter module of 5343B,
that giving signal 4-20 mA ATEX or 5335-A with output of 4-20 mA HART
and ATEX.

MODEL DESCRIPTION
LTS Reed Type Level sensor
CODE 1 RESOLUTION
R-05 Distance between each sensor 5mm
R-10 Distance between each sensor 10mm
R-15 Distance between each sensor 15mm
R-20 Distance between each sensor 20mm
CODE 2 LENGTH
L ... MLG, C to C lenght
CODE 3 OUTPUT
P 3 Wire Potentiometer or Resistance
TU 4-20 mA, 2 wire system-General
5343-B 4-20 mA, 2 wire system-Ex-proof
5335-A 4-20 mA HART, 2 wire system-Ex-proof
CODE 4 ENCLOSURE
0 Aluminium, IP-68
EX Aluminium, Ex-proof, IP-65l
CODE 5 OPTIONS
0 Ambient Temp Max up to 130 Deg C
HT Ambient Temp Max up to 200 Deg C
LTS LTS-R10-L1000-TU-0-0 .................................................................. Example LTS-Ex

TRANSMITTER MODULE & DIGITAL METER

TU 5343B 5335A WP-4 WP-5


MODEL

INPUT 3 Wire Potentiometer 2 Wire Resistant 3 Wire Potentiometer


ALUMINIUM & 316SS
2 x Relays* 2 x Relays + 4-20mA
4-20 mA* Modbus RS-485*
OUTPUT 4-20 mA 4-20 mA Hart 2 x Relays
RS-485 Modbus* * Modbus output option
* Select 1 Output only only for Linear Function
DISPLAY LCD, 0-100% NONE 4 Digits LED, 20mm 5 Digits LED, 20mm 5 Digits LED, 14mm
POWER 10 - 30 Vdc 8 - 35 Vdc 220 Vac or 24 Vdc 220 Vac, 12 Vdc or 24 Vdc
Linear Tank or with
FUNCTION Linear Only 20 points Linearization Linear Only
20 points Linearization
7
ORDERING CODE

A B C D E F G
MODEL DESCRIPTION
MLG Magnetic Level Gauge with Red + White + Yellow Indicator
CODE 1 CHAMBER TYPE
A B C D E F G
CODE 2 PROCESS CONNECTION
1/2" 3/4" 1" 1-1/2" 2"
CODE 3 PROCESS CONNECTION RATING
SB = BSP-Male SN = NPT-Male
FJ10K = JIS 10K FJ5K = JIS 5K
Fa150 = ANSI 150RF or FA300 FD 16 = PN16 or FD 40
CODE 4 MATERIAL
S1 = 304SS S2 = 316SS P = PVC CP = CPVC
CODE 5 LENGTH (C to C)
L ..... Straight Pipe up to 5700mm, Conn Pipe up to 15000 mm
CODE 6 MAGNETIC FLAPPER INDICATOR
FPA PA66+30% GF Flapper, Alum Rail, T max = 200 ºC
CODE 7 FLOATS
FMS...... SS316L Please refer to page 3 & 5
FMP...... PP or PVDF, Please refer to page 4
CODE 8 OPTIONS
0 No Options
MS Magnetic Switch, please refer to page 6
LTS Level Sensor, please refer to page 7
SCA/SCS Cm Scale, please refer to page 6
MLG-A-1FJ10K-S1-L1000-FPA-FMS160-MS .......................................................... Example

Wingel Measurement & Control


PT. TAWIN CITRA INSTRUMENT
Process Instrument & Control
TCI Ruko MIAMI Blok. A-20 CITY RESORT - CENGKARENG
JAKARTA BARAT 11730
Phone : 62-21-56955637, 56955638 / Fax : 62-21-56955636
Email : sales@tawincitra.com , tawin@centrin.net.id / Webside : www.tawincitra.com

Potrebbero piacerti anche